• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 79
  • 1
  • Tagged with
  • 81
  • 43
  • 31
  • 24
  • 22
  • 19
  • 19
  • 18
  • 16
  • 14
  • 13
  • 13
  • 13
  • 12
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Aplicações do formalismo de Keldysh ao transporte e ao bombeamento de calor em nanoestruturas / Applications of the keldysa formalism to the transport and pumping in nanostructures

Leandro Romão Fernandes Lima 06 March 2009 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Num regime balísstico e a baixas temperaturas, a fórmula de Landauer dá uma boa descrição do transporte de calor para nano-junções conectadas a dois fios acoplados a banhos térmicos a temperaturas diferentes. Partindo de um modelo microscópico e utilizando o método de funções de Green fora do equilíbrio, é possível obter uma expressão para a condutância térmica na nano-junção equivalente a fórmula de Landauer. Esta depende dos valores das constantes de acoplamento entre os modos de fônons da região central e dos fios, além do gradiente térmico. A expressão para a condutância térmica é muito semelhante aquela obtida para a condutância elétrica. Neste trabalho nós apresentamos o método para o cálculo de grandezas relacionadas ao transporte térmico em um regime onde não há um gradiente de temperatura entre os reservatórios mas o sistema sofre uma perturbação dependente do tempo. Ou seja, com uma escolha conveniente da parametrização temporal dos termos de acoplamento entre a nano-junção e os fios é possível produzir uma corrente de calor na ausência de diferença de temperaturas entre os banhos térmicos aos quais os fios estão conectados. Esse fenômeno caracteriza o bombeamento de calor. Desenvolvemos uma teoria de transporte dependente do tempo para descrever o bombeamento. A teoria é geral, dependendo da densidade de fônons, da intensidade e dependência temporal do acoplamento. Aplicamos o formalismo em um modelo simples demonstrando que, em princípio, é possível bombear calor através de uma cadeia linear de átomos sem gradiente térmico. / In the ballistic regime at low temperatures, the Landauer formula gives a good description of heat transport for nano-junctions, connected to two leads attached to thermal baths at different temperatures. Starting from a microscopic model and using the nonequilibrium Green functions, it is possible to obtain an expression for the thermal conductance in nano-junction equivalent to the Landauer formula. The latest depends on the values of the coupling constants between phonon modes of the central region and leads, as well as on the thermal gradient. The expression for the thermal conductance is quite similar to that obtained for electrical conductance. In this work we present the method to calculate quantities related to heat transport in a regime where there is no temperature gradient between the reservoirs, but the system suffers a time depending perturbation. That is, with a convenient choice of time parameterization of the coupling terms between the nano-junction and the leads it is possible to produce a heat flow in the absence of a temperature difference between the thermal baths connected to the leads. This phenomenon characterizes the heat pumping. We develop a time-dependent transport theory to describe the pumping. The theory is general, depending on the phonons density, intensity and time dependence of the coupling. We apply the formalism in a simple model showing that in principle it is possible to pump heat through a linear chain of atoms without thermal gradient.
52

Avaliação de sistemas fotovoltaicos de bombeamento / Evaluation of Photovoltaic Pumping Systems

Teddy Arturo Flores Melendez 22 April 2009 (has links)
A presente dissertação aborda a avaliação de três sistemas fotovoltaicos de bombeamento, que compreendem duas configurações com equipamentos dedicados à tecnologia fotovoltaica e um com equipamentos alternativos com potências entre 0,75 CV e 1,0 CV. Os resultados mostram que a configuração alternativa apresenta menor eficiência diária do sistema motobomba. A avaliação econômica revela a competitividade da configuração alternativa frente aos sistemas importados dedicados à tecnologia fotovoltaica. Alia-se a isso a disponibilidade dos equipamentos de condicionamento de potência e a facilidade de reposição. Verificou-se também que a configuração alternativa, conversor de freqüência WEG CFW08 e motobomba SOMAR de 1,0 CV e 8 estágios, trabalha com eficiência diária próxima aos 30% na faixa de operação de 20 a 40 metros de coluna dágua. Portanto, com uma adequada escolha da motobomba para a configuração alternativa, podem-se obter desempenhos semelhantes aos obtidos com sistemas importados dedicados à tecnologia fotovoltaica. Para 30 metros, a configuração alternativa bombeou somente 1% a menos do que o sistema Grundfos. O custo do volume bombeado para 30m de altura manométrica total do sistema alternativo é 22% menor do que o sistema Grundfos e 51% mais econômico do que o sistema Solarjack (Sun Pumps). / The present dissertation shows the evaluation of three Photovoltaic Pumping Systems, which involves two configurations: the equipment dedicated to the photovoltaic technology and the alternative equipment with nominal powers between 0.75 CV and 1.0 CV. The results show that the alternative configuration attained minor daily efficiency of the motopump system. The economic evaluation reveals the competitiveness of the alternative configuration in comparison with imported photovoltaic technology dedicated systems. It also should be considered the availability of equipment for power conditioning and the facility of replacement. It was also verified that the alternative configuration, variable speed drive WEG CFW08 and 1.0 CV SOMAR motor pump with 8 stages, works with daily efficiency near 30% in the 20 to 40 meters operation range. Therefore, with an adequate choice of the motor pump for the alternative configuration, performances similar to the imported photovoltaic technology dedicated systems can be obtained. For 30 meters, the alternative configuration pumped only 1% less than the Grundfos system. The cost of pumped volume for 30 meters of manometer total height of the alternative system is 22% cheaper than the system Grundfos and 51% cheaper than the system Solarjack (Sun Pumps).
53

Avaliação de um sistema de bombeamento de água alimentado por painéis fotovoltaicos / Evaluation of a water pumping system fed by photovoltaic panels

Michels, Roger Nabeyama 06 June 2007 (has links)
Made available in DSpace on 2017-05-12T14:46:59Z (GMT). No. of bitstreams: 1 Roger Nabeyama Michels.pdf: 4361240 bytes, checksum: 896b2cd719d7885b070fecc71373f7e7 (MD5) Previous issue date: 2007-06-06 / The current dissertation describes an experiment to evaluate a water pumping system activated by two photovoltaic panels installed at The Federal Technological University of Paraná FTUPR, Medianeira Campus, in the State of Paraná, Brazil. The city of Medianeira s latitude and longitude are 25º17 43 south and 54º03 38 west respectively, with an altitude of 500.7 meters (1,642.72 feet). The system operated in a real working situation, pumping water to a 20 meters (65.62 feet) elevation. Data were collected, from February 2005 to November 2005, by means of a computerized data collector made by Campbell Scientific Inc that made possible collecting and applying irradiance values in the panel plane, generated current and tension, panel temperature, pressure and consume. Data readings were made at a 1-hertz frequency and stored every minute. Through calculi, the system efficiency and energy values and hydraulic strength were obtained. Winter solstice showed 9.58% efficiency with daily pumping of 2,056.44 liters (543.14 gallons) whereas summer solstice confirmed 9.07% efficiency with daily pumping of 2,377.21 liters (627.86 gallons). Winter day s highest efficiency is associated to the lowest temperature in those days compared to summer days, and the factor that prompted larger pumped water consume, during summer days, was related to solar insulation time that is longer if compared to winter days. Total water pumped during the experiment period was 435,042.20 liters (114,900.99 Gallons). / A presente dissertação descreve o experimento desenvolvido com a finalidade de avaliar um sistema de bombeamento de água acionado por dois painéis fotovoltaicos instalado nas dependências da Universidade Tecnológica Federal do Paraná UTFPR, Campus Medianeira, estado do Paraná, Brasil. O município está localizado no oeste paranaense com 25º17 43 Latitude sul, 54º03 38 Longitude oeste e com altitude de 500,7 metros. O sistema trabalhou em situação real de funcionamento, bombeando água a uma altura de 20 metros. Foram coletados dados de fevereiro de 2005 a novembro de 2005; utilizou-se um coletor de dados computadorizado da marca Campbell Scientific INC., o que possibilitou adquirir e armazenar os valores de irradiância no plano do painel, tensão e corrente gerada, temperatura no painel, pressão e vazão. A leitura dos dados foi realizada com freqüência de 1 hertz e armazenada a cada 1 minuto. Através de cálculos obtiveram-se os valores de potência e eficiência do sistema e a potência hidráulica. O solstício de inverno apresentou eficiência de 9,58% com bombeamento diário de 2.056,44 litros, enquanto que o solstício de verão apresentou eficiência de 9,07% com bombeamento diário de 2.377,21 litros. A maior eficiência nos dias de inverno está atrelada às menores temperaturas nestes dias se comparado aos dias de verão e o fator que provocou uma maior vazão de água bombeada nos dias de verão está ligado ao tempo de insolação solar que é maior se comparado aos dias de inverno. O total de água bombeada durante o período do experimento foi de 435.042,20 litros.
54

Sistemas de bombeamento de água com velocidade de rotação variável

Kuritza, Jóice Cristini January 2017 (has links)
O consumo de energia dispendido pelos sistemas de bombeamento apresenta valores elevados e que podem onerar a operação dos sistemas de abastecimento de água realizada pelas companhias de saneamento. Assim, esta pesquisa está centrada no desenvolvimento de uma metodologia para análise da eficiência energética desses sistemas. O procedimento metodológico foi desenvolvido para uma tipologia genérica de sistema composta de dois reservatórios, inferior e superior, um conjunto motobomba e uma adutora, responsável pelo transporte de água entre eles. Foram avaliadas 96 possibilidades geométricas para esse sistema, formadas a partir da combinação de diferentes alturas geométricas, comprimentos e diâmetros da linha adutora. Ainda, foram estudados três formatos de curva, com quatro volumes de consumo diário distintos, em duas situações, início e fim de projeto. O algoritmo Shuffled Complex Evolution – SCE-UA foi empregado para obter a regra de operação otimizada do sistema de bombeamento e a função-objetivo foi formulada para representar os custos de energia para 20 anos de operação somado aos custos de instalação do sistema de bombeamento (adutora, reservatório superior e conjunto motobomba). Além disso, foram calculados índices e indicadores para facilitar o entendimento e a avaliação da eficiência energética de sistemas de bombeamento. A partir da análise dos resultados dos sistemas cuja operação foi otimizada, e dos resultados dos índices e indicadores, foram estabelecidos critérios e equações que podem ser utilizados para análise da operação, dimensionamento e eficiência energética de sistemas de bombeamento de água. Também, foi desenvolvida uma metodologia para a estimativa da energia mínima que um sistema de bombeamento pode consumir se todos os critérios de eficiência energética forem satisfeitos, ou seja, quando todas as grandezas que compõem o cálculo da energia forem determinadas a partir de critérios otimizados. Essa metodologia foi aplicada em dois cenários: projetos de sistemas de bombeamento de água e diagnóstico de sistemas de bombeamento de água existentes. Na primeira abordagem, o indicador se mostrou útil para inferir sobre consumo de energia e, inclusive, definir o diâmetro ótimo da linha adutora com maior ponderação. Já na segunda abordagem, o indicador tem potencial para ser utilizado na definição da linha de base do sistema e pode auxiliar a tomada de decisão e gestão hidroenergética desses sistemas. / The energy consumed by the pumping systems has high values and can overload the operation of the water supply systems carried out by the sanitation companies. Thus, this research is focused on the development of a methodology to analyze the energy efficiency of these systems. The methodological procedure was developed for a generic system composed of two reservoirs, upper and lower, pumping system and a pipeline, responsible for transporting water between the reservoirs. It was evaluated 96 geometric possibilities for this system, formed from the combination of different static heights, lengths and diameters of the pipeline. Also, three curve formats were studied, with four distinct daily consumption volumes, in two situations, beginning and end of the project. The Shuffled Complex Evolution (SCE-UA) algorithm was employed to obtain the optimal operating rule for the pumping system and the objective function was formulated to represent the energy costs for 20 years of operation plus the pumping system installation costs (pipeline, upper reservoir and pumping system). In addition, indexes and indicators were calculated to facilitate the understanding and evaluation of the energy efficiency of pumping systems. Based on the analysis of the results of the systems whose operation was optimized, and the results of indexes and indicators, criteria and equations were established that can be used to analyze the operation, design and energy efficiency of water pumping systems. Also, a methodology was developed to estimate the minimum energy that a pumping system can consume if all the energy efficiency criteria are met, that is, when all the quantities that compose the energy calculation are determined from optimized criteria. This methodology was applied in two scenarios: projects of water pumping systems and diagnosis of existing water pumping systems. In the first approach, the indicator was useful to infer about energy consumption and, even, to define the optimum diameter of the most heavily weighted pipeline. In the second approach, the indicator has the potential to be used in the definition of the baseline of the system and may help decision making and hydropower management of these systems.
55

[en] NUMERICAL SIMULATION OF A GAS-LIQUID MIXER FOR PUMPING STATIONS / [pt] SIMULAÇÃO NUMÉRICA DE UM MISTURADOR GÁS-LÍQUIDO PARA ESTAÇÕES DE BOMBEIO

LEONARDO CHAGAS CARBONE 26 January 2016 (has links)
[pt] A produção de petróleo offshore tem requerido cada vez mais a utilização de equipamentos de bombeio no leito marinho para a produção de poços a longas distâncias das unidades de produção. A grande maioria destes equipamentos tem dificuldade de operar com a presença de gás, ainda mais em condições de golfadas, onde a fração de vazio na sucção pode variar significativamente. Isto limita enormemente a janela operacional dos equipamentos. Uma forma de minimizar os efeitos das golfadas e, assim, ampliar a janela de operação destes equipamentos é a instalação de misturadores de fluxo na sucção das bombas, que atuam de forma a garantir uma maior sobrevida ao equipamento. Portanto, o projeto e a previsão do comportamento deste tipo de equipamento são fundamentais para bom funcionamento dos sistemas de bombeamento submarino. O presente trabalho investiga numericamente, com o modelo de dois fluidos, a eficiência de um tipo de misturador em uniformizar as frações de vazio. Diferentes configurações geométricas são analisadas e a influência das vazões de admissão de ambas as fases é discutida. A metodologia é validada através da comparação da queda de pressão através do misturador com dados experimentais disponíveis, onde se observou boa concordância. O modelo numérico mostra ainda que uma reserva de líquido é mantida no interior do equipamento e, o gás é forçado a se dispersar na corrente de líquido para sair do misturador. O comportamento do misturador frente à presença de golfadas também é investigado. Ao final do trabalho é proposta uma nova geometria, que se mostra mais tolerante a intermitências no escoamento. / [en] The offshore oil production is increasingly using pumping equipment at the seabed for production of wells at long distances from production units. Most of these devices have difficulty to operate in the presence of gas, especially in slug flow conditions, where the pump suction s void fraction can vary significantly. This problem limits the equipment s range of operation. One way to minimize the effects of slugging and thus enlarge the operation range of these devices is to use flow mixers at the pump s suction, which helps to ensure the operation even in the presence of large gas bubbles. Therefore, the design and prediction of the behavior of this type of equipment are essential for proper operation of subsea pumping systems. At the present work, the efficiency of a type of flow mixer to provide uniform void fractions at its outlet is numerically investigated, with the two fluid model. Different geometric configurations are analyzed and the influence of intake flow of both phases is discussed. The methodology is validated through comparison of the pressure drop through the flow mixer with available experimental data, where good agreement was observed. The numerical model also shows that a buffer of liquid is maintained inside the equipment and the gas is forced to disperse in the liquid stream to exit the mixer. The mixer s behavior in the presence of slugs is also investigated. Finally, a new geometry is proposed, which seems to be more efficient to avoid flow s intermittencies.
56

A difusão do acesso à água com sistemas fotovoltaicos de bombeamento no semiárido brasileiro

Morais, Albemerc Moura de January 2015 (has links)
Orientador: Prof. Dr. Federico Bernardino Morante Trigoso / Tese ( doutorado)- Universidade Federal do ABC. Programa de Pós-Graduação em Energia, 2015. / Várias são as soluções tecnológicas disponíveis para o acesso à água no meio rural. Dentre elas, a opção fotovoltaica apresenta-se consolidada e competitiva, podendo suprir a demanda de água em comunidades rurais dispersas. Contudo, experiências ao redor do mundo demonstram que muitos empreendimentos têm falhado por não considerarem as peculiaridades locais e os processos adequados de introdução e manutenção da nova tecnologia. Dessa forma, por meio desta pesquisa, pretendeu-se identificar os principais entraves ao sucesso de empreendimentos de abastecimento de água em regiões semiáridas baseados na tecnologia solar fotovoltaica e recomendar formas para a superação de tais entraves de acordo com boas práticas na implantação e gestão desses sistemas. Nesse contexto, foi proposto um indicativo de política pública para potencializar a difusão e inserção tecnológica da opção fotovoltaica de bombeamento no Território Vale do Rio Canindé, semiárido piauiense. Verificou-se, nesse cenário, que para possibilitar a difusão do uso da tecnologia solar fotovoltaica nesse território é necessário inicialmente o desenvolvimento de um programa de capacitação e formação de mão de obra especializada, bem como a realização de um amplo programa governamental de incentivo que possibilite o aproveitamento do leque de instituições existentes e as potencialidades produtivas locais. / Several technological solutions exist to access to provide water in rural areas. Among them, the photovoltaic option is competitive and consolidated option to supply the demand for water in remote rural communities. However, experiences around the world show that many projects have failed by not considering the local peculiarities and adequate procedures of introduction and maintenance of the new technology. Thus, through this research, we intend to identify the main barriers to the success of water supply projects in semi-arid regions based on solar photovoltaic technology, and recommend ways to overcome these barriers in accordance with best practices in the implementation and management of systems. In this context, a suggestion of public policy is proposed to enhance the dissemination and technological integration of photovoltaic pumping option in the Caninde River Valley, Piauí semiarid. It was found, in this scenario, that to enable the widespread use of photovoltaic solar technology in this area is necessary, as a first step, the development of a training program and training skill labor, as well as the implementation of a governments program of incentives that would enable the use of the range of the existing institutions and the local productive potential.
57

Sistema inteligente para o controle de pressão De redes de distribuição de água abastecidas Por bombas associadas em paralelo

Barros Filho, Emânuel Guerra de 05 December 2016 (has links)
Submitted by Maike Costa (maiksebas@gmail.com) on 2017-05-26T11:40:16Z No. of bitstreams: 1 arquivototal.pdf: 8290765 bytes, checksum: 60cc04d99eb6779eb21f6ce5385803d1 (MD5) / Made available in DSpace on 2017-05-26T11:40:17Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 8290765 bytes, checksum: 60cc04d99eb6779eb21f6ce5385803d1 (MD5) Previous issue date: 2016-12-05 / The objective of this research is to develop an intelligent system based on artificial neural networks for water distribution systems that operate with pumps associated in parallel. The system aims at process automation and the definition of operating state for electric motors (on, off or with partial rotation), aiming at the same time the pressure control and reduction of electric power consumption. The developed intelligent system is a generic one, which allows the application of control structure in similar processes, and it was applied in a fully instrumented test rig that emulates a real system of water supply. The results showed that the performance of the artificial neural network is quite satisfactory, and thus can be successfully implemented in other similar water distribution systems in order to reduce consumption of water and electric energy, decrease costs of maintenance, and increase the degree of reliability of operational procedures. / O objetivo desta pesquisa é desenvolver um sistema inteligente baseado em redes neurais artificiais para redes de distribuição de água que operam com bombas associadas em paralelo. O sistema tem por finalidade a automação do processo e a definição do estado de funcionamento dos motores elétricos (ligado, desligado ou com rotação parcial), visando simultaneamente ao controle de pressão e à redução do consumo de energia elétrica. O sistema inteligente desenvolvido é genérico, o que permite a aplicação da estrutura de controle em processos semelhantes, e foi aplicado em uma bancada experimental totalmente instrumentalizada que emula um sistema real de abastecimento de água. Os resultados mostraram que o desempenho da rede neural artificial é bastante satisfatório, e, assim, poderá ser implementada com sucesso em outros sistemas de distribuição de água similares, a fim de proporcionar redução do consumo de água e energia elétrica, diminuição dos custos de manutenção e aumento do grau de confiabilidade dos procedimentos operacionais.
58

Controle para bombeamento distribuído com vistas à minimização dos custos energéticos aplicado a sistemas de abastecimento de água / Distributed control for pumping with a view to minimizing costs of energy applied to water supply systems

Carvalho, Paulo Sergio Oliveira de 20 June 2012 (has links)
Made available in DSpace on 2015-05-08T14:59:42Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 5430085 bytes, checksum: 2ce42198a2dd4ca16f3d08b584e0513c (MD5) Previous issue date: 2012-06-20 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The objective of this research was to develop a nonlinear controller, using the technique of fuzzy intelligent control, apply to networks pressurized water distribution sectored, automated and distributed pumping system in order to minimize energy consumption. The methodology used was based on the performance of several tests using an instrumented experimental network, where the control system can be tested and evaluated. The experimental system has pressure transducers and flow, variable speed driven, proportional control valves and water distribution lines, with different topologies that allow you to simulate dynamically different situations operational supply network, depending on the variation of demand water over time. The supervisory system built acquires the necessary data, provided by the network monitoring tools. The controller module of the supervisory system processes data in real time, tuning the instruments to carefully control the experimental network. We performed numerous tests with different operating conditions in order to extract rules and various combinations of control, to optimize the balance of pressures on the network and reduce energy consumption. The results obtained proved that it is more economical to operate the network with the two sets of pumping, for all ranges of consumption studied. Besides the economic aspect, which indicated an energy saving of around 12.17%, the controller gave better performance to achieve and balance the pressures of the network with the pumping action of two acting simultaneously. / O objetivo nesta pesquisa foi desenvolver um controlador não-linear, utilizando a técnica de controle inteligente fuzzy, aplicável a redes pressurizadas de distribuição de água setorizadas, automatizadas e com sistema de bombeamento distribuído, visando minimizar o consumo de energia elétrica. A metodologia empregada foi baseada na realização de diversos ensaios utilizando uma rede experimental instrumentalizada, onde o sistema de controle pode ser testado e avaliado. O sistema experimental possui transdutores de pressão e de vazão, conversores de frequência, válvulas com controle proporcional e ramais de distribuição de água, com topologias diferentes que permitem simular, dinamicamente, diversas situações operacionais da rede de abastecimento, em função da variação da demanda de água ao longo do tempo. O sistema supervisório construído adquire os dados necessários, fornecidos pelos instrumentos de monitoramento da rede. O módulo controlador do sistema supervisório processa os dados, em tempo real, sintonizando de forma criteriosa os instrumentos de controle da rede experimental. Foram realizados inúmeros ensaios com diferentes condições operacionais, visando extrair regras e combinações diversas de controle, para otimizar o equilíbrio das pressões na rede e reduzir o consumo energético. Os resultados obtidos comprovaram que é mais econômico operar a rede com os dois conjuntos de bombeamento, para todas as faixas de consumo estudadas. Além do aspecto econômico, que indicou uma economia de energia da ordem de 12,17%, o controlador proporcionou um melhor desempenho para atingir e equilibrar as pressões da rede com a ação dos dois bombeamentos atuando simultaneamente.
59

Potencial energético de um sistema de bombeamento de água via membrana de microfiltração. / Potential energy of a water pumping system via membrane microfiltration

SILVA, Robson Rogaciano Fernandes da. 20 April 2018 (has links)
Submitted by Jesiel Ferreira Gomes (jesielgomes@ufcg.edu.br) on 2018-04-20T19:47:10Z No. of bitstreams: 1 ROBSON ROGACIANO FERNANDES DA SILVA – DISSERTAÇÃO (PPGEQ) 2015.pdf: 2972393 bytes, checksum: 0382c6be9c4c653ce0885143a6cf932d (MD5) / Made available in DSpace on 2018-04-20T19:47:10Z (GMT). No. of bitstreams: 1 ROBSON ROGACIANO FERNANDES DA SILVA – DISSERTAÇÃO (PPGEQ) 2015.pdf: 2972393 bytes, checksum: 0382c6be9c4c653ce0885143a6cf932d (MD5) Previous issue date: 2014-03 / Capes / Este trabalho trata do estudo da potencialidade energética de geradores fotovoltaicos em acionar um sistema de bombeamento de água via processo de microfiltração. A avaliação do sistema permitiu caracterizar o efeito da disponibilidade de potencia elétrica e da pressão de operação do sistema, para determinação da quantidade de água produzida. Na avaliação do sistema, foi utilizada uma alimentação de água da Cisterna do LABDES (água da chuva captada pelas telhas), fazendo uso de um Motor Bomba Centrifuga de potê ncia de 0,5 Hp, e atuando com variações de pressões entre 0 a 2 kgf/cm². Inicialmente, foi realizada a caracterização do sistema, através de sua operação com disponibilidade de potência elétrica variável (Energia convencional), sendo verificado seu perfil de funcionamento a partir da avaliação dos seguintes parâmetros: vazão do permeado, Pressão, Potência e remoção de cor e turbidez. A avaliação do sistema, permitiu caracterizar o efeito da disponibilidade de potência elétrica e da pressão de operação do sistema na quantificação e qualidade da água produzida. Utilizando os dados do potencial solarimétrico (LEIAM-UFCG) da cidade de Campina Grande – PB, para o período de Outubro/2013 à Setembro/2014, realizou-se um estudo da oferta de energia solar disponibilizada para o período especificado, onde verificou-se que 70,5% da irradiação média mensal encontra-se na faixa entre 200 e 1400 W/m². Posteriormente, avaliou-se o funcionamento do sistema operando efetivamente com energia solar fotovoltaica, o qual atingiu uma produção média de 0,36 L/min ou 174,4 L/dia (média dos Dias 1,Dias 2 e Dias 3), durante 8 horas de funcionamento do sistema por dia. Com uma pressão média de operação de 0,99 kgf/cm² durante os 3 dias. / This work deals with the study of the effectiveness of photovoltaic generators drive a via microfiltration water pumping system. The rating system allows to characterize the effect of the availability of electric power and operation of the system pressure to determine the amount of water produced. In the evaluation system used was a cistern of the water supply LABDES (rainwater captured by tile), using a 0.5 hp motor pump power centrifuged, and the variations in operating pressures from 0 to 2 kgf/cm2. Initially the system characterization was performed by means of operation with variable availability of electrical power (conventional Energy), confirmed its working profile from the evaluation parameters: permeate flow, pressure, power and removing color and turbidity. The rating system allowed us to characterize the effect of the availability and the electrical power system operating pressure in the quantity and quality of water produced. Using potential data solarimetric (read-UFCG) of Campina Grande - PB for the period October / 2013 to September / 2014, there was a study of solar energy supply available for the specified period, where it was found that 70.5% of the monthly average irradiation is between 200 and 1400 W / m2. Subsequently, we evaluated the system works effectively operating with photovoltaic solar energy, which reached an average production of 0.36 L / min or 174.4 L / day (mean of Days 1, 2 Days and Days 3) for 8 hours of operation of the system per day, with an average operating pressure of 0.99 kgf / cm² for 3 days.
60

Simulação de transiente hidráulico e combinação econômica da adutora para abastecimento público do município de Torrinha - SP /

Schimidt, Marcos Jorge Assumpção, 1959. January 2016 (has links)
Orientador: João Luis Zocoler / Coorientador: Rodrigo Máximo Sánchesz-Román / Banca: João Carlos Cury Saad / Banca: Marconi Batista Teixeira / Resumo: O abastecimento público é um dos grandes desafios das autoridades em prover a sociedade com água de qualidade e em quantidade. O aumento da demanda por este recurso natural exige projetos de captação e transporte cada vez maiores e mais complexos. Um projeto hidráulico deve ser concebido para operar sob condições normais de escoamento e também sob condições extremas, causadas por agentes externos que possam gerar pressões muito maiores ou muito menores às condições ideais de funcionamento. Este trabalho teve por objetivos definir o desenho de bombeamento público para o abastecimento da cidade de Torrinha, município do Estado de São Paulo; determinar qual alternativa de combinação de tubulações é a melhor solução hidráulica e econômica; e verificar a necessidade e definir a proteção contra transiente hidráulico. Utilizou-se o programa Allievi para realizar as cinco simulações propostas: Simulação 1 (S1): regime permanente; Simulação 2 (S2): linha com tubos de ferro fundido sem proteção; Simulação 3 (S3): linha com tubos de PVC-O sem proteção; Simulação 4 (S4): linha com tubos de PVC-O com proteção; Simulação 5 (S5): linha com tubos de ferro fundido e de PVC-12 DeFoFo com proteção. A partir dos resultados concluiu-se que na simulação 5 obteve-se a melhor opção econômica e hidráulica, consistindo em construir a linha com os primeiros 3391,79 metros de tubos de ferro fundido, ponta bolsa, K7 e 3297,33 metros restantes com tubos de PVC 12 DeFoFo; e a utilização do dispositivo RHO com bexiga de 1,5 m³ de capacidade para proteção contra transiente hidráulico. As simulações S2 e S3 evidenciaram um ganho de rendimento do grupo motobomba e a opção S1 é a que mostrou a melhor combinação vazão-altura... / Abstract: O abastecimento público é um dos grandes desafios das autoridades em prover a sociedade com água de qualidade e em quantidade. O aumento da demanda por este recurso natural exige projetos de captação e transporte cada vez maiores e mais complexos. Um projeto hidráulico deve ser concebido para operar sob condições normais de escoamento e também sob condições extremas, causadas por agentes externos que possam gerar pressões muito maiores ou muito menores às condições ideais de funcionamento. Este trabalho teve por objetivos definir o desenho de bombeamento público para o abastecimento da cidade de Torrinha, município do Estado de São Paulo; determinar qual alternativa de combinação de tubulações é a melhor solução hidráulica e econômica; e verificar a necessidade e definir a proteção contra transiente hidráulico. Utilizou-se o programa Allievi para realizar as cinco simulações propostas: Simulação 1 (S1): regime permanente; Simulação 2 (S2): linha com tubos de ferro fundido sem proteção; Simulação 3 (S3): linha com tubos de PVC-O sem proteção; Simulação 4 (S4): linha com tubos de PVC-O com proteção; Simulação 5 (S5): linha com tubos de ferro fundido e de PVC-12 DeFoFo com proteção. A partir dos resultados concluiu-se que na simulação 5 obteve-se a melhor opção econômica e hidráulica, consistindo em construir a linha com os primeiros 3391,79 metros de tubos de ferro fundido, ponta bolsa, K7 e 3297,33 metros restantes com tubos de PVC 12 DeFoFo; e a utilização do dispositivo RHO com bexiga de 1,5 m³ de capacidade para proteção contra transiente hidráulico. As simulações S2 e S3 evidenciaram um ganho de rendimento do grupo motobomba e a opção S1 é a que mostrou a melhor combinação vazão-altura... / Mestre

Page generated in 0.0803 seconds