Ferramenta computacional para análise do potencial de bombeamento de água utilizando aerogeradores de pequeno porte acoplados a motobombas por meio de inversores de frequênciaNASCIMENTO, Max Alexandre Seabra do 26 April 2012 (has links)
Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2013-03-20T18:01:59Z
No. of bitstreams: 2
license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5)
Dissertacao_FerramentaComputacionalAnalise.pdf: 5164783 bytes, checksum: 86f7882d5ca2558eb263a396e1c96241 (MD5) / Approved for entry into archive by Ana Rosa Silva(arosa@ufpa.br) on 2013-03-27T15:53:00Z (GMT) No. of bitstreams: 2
license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5)
Dissertacao_FerramentaComputacionalAnalise.pdf: 5164783 bytes, checksum: 86f7882d5ca2558eb263a396e1c96241 (MD5) / Made available in DSpace on 2013-03-27T15:53:00Z (GMT). No. of bitstreams: 2
license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5)
Dissertacao_FerramentaComputacionalAnalise.pdf: 5164783 bytes, checksum: 86f7882d5ca2558eb263a396e1c96241 (MD5)
Previous issue date: 2012 / FINEP - Financiadora de Estudos e Projetos / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / FAPESPA - Fundação Amazônia de Amparo a Estudos e Pesquisas / O objetivo desta dissertação é desenvolver uma ferramenta computacional para a análise do potencial de bombeamento de água com base nos valores de velocidades de vento de uma localidade, utilizando um aerogerador de pequeno porte acoplado a um conjunto motobomba convencional, por intermédio de um inversor de frequência. No trabalho são apresentados dois métodos para o cálculo da vazão. O método 1 utiliza um modelo teórico, enquanto que no método 2 o modelamento é feito a partir de dados de bombeamento obtidos em laboratório. Os dois métodos descrevem o funcionamento de um sistema de bombeamento de água envolvendo os equipamentos citados. Utilizando os modelos matemáticos descritos, foi criado um programa em linguagem Delphi®, para a obtenção dos valores de vazão e volume de água bombeada, além do número de pessoas que podem ser atendidas, com base nos dados de velocidade de vento do local, para com isso, ser possível analisar a viabilidade ou não de instalação do sistema. O funcionamento do programa é descrito através de um exemplo, que contém valores reais de velocidade de vento, e cujos resultados são analisados de forma a possibilitar seu entendimento. / The goal of this dissertation is to allow, through a computational tool, the analysis of the potential of a water pumping system based on the values of wind speeds in one location, using a small wind turbine coupled to a centrifugal pump through a variable speed drive. In the work two methods for the calculation of the flow are presented. Method 1 uses a theoretical model, while in method 2 the modeling is done from pumping data obtained in laboratory. The two methods describe the operation of a water pumping system involving the above equipment. Using the mathematical models described, a program was developed in Delphi® to obtain the values for the flow and volume of pumped water, and the number of people that can be supplied on the basis of the data of wind speed for the site, in order to analyze the feasibility of the system. The operation of the program is described through an example, in order to facilitate its understanding, which contains real values of wind speed, and the results are analyzed.
|
52 |
Aplicações do formalismo de Keldysh ao transporte e ao bombeamento de calor em nanoestruturas / Applications of the keldysa formalism to the transport and pumping in nanostructuresLeandro Romão Fernandes Lima 06 March 2009 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Num regime balísstico e a baixas temperaturas, a fórmula de Landauer dá uma boa descrição do transporte de calor para nano-junções conectadas a dois fios acoplados a banhos
térmicos a temperaturas diferentes. Partindo de um modelo microscópico e utilizando o método de funções de Green fora do equilíbrio, é possível obter uma expressão para a condutância
térmica na nano-junção equivalente a fórmula de Landauer. Esta depende dos valores das constantes de acoplamento entre os modos de fônons da região central e dos fios, além do gradiente
térmico. A expressão para a condutância térmica é muito semelhante aquela obtida para a condutância elétrica. Neste trabalho nós apresentamos o método para o cálculo de grandezas relacionadas ao transporte térmico em um regime onde não há um gradiente de temperatura entre os reservatórios mas o sistema sofre uma perturbação dependente do tempo. Ou seja, com uma escolha conveniente da parametrização temporal dos termos de acoplamento entre a
nano-junção e os fios é possível produzir uma corrente de calor na ausência de diferença de temperaturas entre os banhos térmicos aos quais os fios estão conectados. Esse fenômeno caracteriza o bombeamento de calor. Desenvolvemos uma teoria de transporte dependente do tempo para descrever o bombeamento. A teoria é geral, dependendo da densidade de fônons, da intensidade e dependência temporal do acoplamento. Aplicamos o formalismo em um modelo simples demonstrando que, em princípio, é possível bombear calor através de uma cadeia linear de átomos sem gradiente térmico. / In the ballistic regime at low temperatures, the Landauer formula gives a good description of heat transport for nano-junctions, connected to two leads attached to thermal baths at different temperatures. Starting from a microscopic model and using the nonequilibrium Green
functions, it is possible to obtain an expression for the thermal conductance in nano-junction equivalent to the Landauer formula. The latest depends on the values of the coupling constants between phonon modes of the central region and leads, as well as on the thermal gradient. The
expression for the thermal conductance is quite similar to that obtained for electrical conductance. In this work we present the method to calculate quantities related to heat transport in a regime where there is no temperature gradient between the reservoirs, but the system suffers a
time depending perturbation. That is, with a convenient choice of time parameterization of the coupling terms between the nano-junction and the leads it is possible to produce a heat flow in the absence of a temperature difference between the thermal baths connected to the leads. This phenomenon characterizes the heat pumping. We develop a time-dependent transport theory to describe the pumping. The theory is general, depending on the phonons density, intensity and time dependence of the coupling. We apply the formalism in a simple model showing that in principle it is possible to pump heat through a linear chain of atoms without thermal gradient.
|
53 |
Avaliação de sistemas fotovoltaicos de bombeamento / Evaluation of Photovoltaic Pumping SystemsTeddy Arturo Flores Melendez 22 April 2009 (has links)
A presente dissertação aborda a avaliação de três sistemas fotovoltaicos de bombeamento, que compreendem duas configurações com equipamentos dedicados à tecnologia fotovoltaica e um com equipamentos alternativos com potências entre 0,75 CV e 1,0 CV. Os resultados mostram que a configuração alternativa apresenta menor eficiência diária do sistema motobomba. A avaliação econômica revela a competitividade da configuração alternativa frente aos sistemas importados dedicados à tecnologia fotovoltaica. Alia-se a isso a disponibilidade dos equipamentos de condicionamento de potência e a facilidade de reposição. Verificou-se também que a configuração alternativa, conversor de freqüência WEG CFW08 e motobomba SOMAR de 1,0 CV e 8 estágios, trabalha com eficiência diária próxima aos 30% na faixa de operação de 20 a 40 metros de coluna dágua. Portanto, com uma adequada escolha da motobomba para a configuração alternativa, podem-se obter desempenhos semelhantes aos obtidos com sistemas importados dedicados à tecnologia fotovoltaica. Para 30 metros, a configuração alternativa bombeou somente 1% a menos do que o sistema Grundfos. O custo do volume bombeado para 30m de altura manométrica total do sistema alternativo é 22% menor do que o sistema Grundfos e 51% mais econômico do que o sistema Solarjack (Sun Pumps). / The present dissertation shows the evaluation of three Photovoltaic Pumping Systems, which involves two configurations: the equipment dedicated to the photovoltaic technology and the alternative equipment with nominal powers between 0.75 CV and 1.0 CV. The results show that the alternative configuration attained minor daily efficiency of the motopump system. The economic evaluation reveals the competitiveness of the alternative configuration in comparison with imported photovoltaic technology dedicated systems. It also should be considered the availability of equipment for power conditioning and the facility of replacement. It was also verified that the alternative configuration, variable speed drive WEG CFW08 and 1.0 CV SOMAR motor pump with 8 stages, works with daily efficiency near 30% in the 20 to 40 meters operation range. Therefore, with an adequate choice of the motor pump for the alternative configuration, performances similar to the imported photovoltaic technology dedicated systems can be obtained. For 30 meters, the alternative configuration pumped only 1% less than the Grundfos system. The cost of pumped volume for 30 meters of manometer total height of the alternative system is 22% cheaper than the system Grundfos and 51% cheaper than the system Solarjack (Sun Pumps).
|
54 |
Avaliação de um sistema de bombeamento de água alimentado por painéis fotovoltaicos / Evaluation of a water pumping system fed by photovoltaic panelsMichels, Roger Nabeyama 06 June 2007 (has links)
Made available in DSpace on 2017-05-12T14:46:59Z (GMT). No. of bitstreams: 1
Roger Nabeyama Michels.pdf: 4361240 bytes, checksum: 896b2cd719d7885b070fecc71373f7e7 (MD5)
Previous issue date: 2007-06-06 / The current dissertation describes an experiment to evaluate a water
pumping system activated by two photovoltaic panels installed at The Federal
Technological University of Paraná FTUPR, Medianeira Campus, in the State
of Paraná, Brazil. The city of Medianeira s latitude and longitude are
25º17 43 south and 54º03 38 west respectively, with an altitude of 500.7 meters
(1,642.72 feet). The system operated in a real working situation, pumping water
to a 20 meters (65.62 feet) elevation. Data were collected, from February 2005
to November 2005, by means of a computerized data collector made by
Campbell Scientific Inc that made possible collecting and applying irradiance
values in the panel plane, generated current and tension, panel temperature,
pressure and consume. Data readings were made at a 1-hertz frequency and
stored every minute. Through calculi, the system efficiency and energy values
and hydraulic strength were obtained. Winter solstice showed 9.58% efficiency
with daily pumping of 2,056.44 liters (543.14 gallons) whereas summer solstice
confirmed 9.07% efficiency with daily pumping of 2,377.21 liters (627.86
gallons). Winter day s highest efficiency is associated to the lowest temperature
in those days compared to summer days, and the factor that prompted larger
pumped water consume, during summer days, was related to solar insulation
time that is longer if compared to winter days. Total water pumped during the
experiment period was 435,042.20 liters (114,900.99 Gallons). / A presente dissertação descreve o experimento desenvolvido com a finalidade
de avaliar um sistema de bombeamento de água acionado por dois painéis
fotovoltaicos instalado nas dependências da Universidade Tecnológica Federal
do Paraná UTFPR, Campus Medianeira, estado do Paraná, Brasil. O
município está localizado no oeste paranaense com 25º17 43 Latitude sul,
54º03 38 Longitude oeste e com altitude de 500,7 metros. O sistema trabalhou
em situação real de funcionamento, bombeando água a uma altura de 20
metros. Foram coletados dados de fevereiro de 2005 a novembro de 2005;
utilizou-se um coletor de dados computadorizado da marca Campbell Scientific
INC., o que possibilitou adquirir e armazenar os valores de irradiância no plano
do painel, tensão e corrente gerada, temperatura no painel, pressão e vazão. A
leitura dos dados foi realizada com freqüência de 1 hertz e armazenada a cada
1 minuto. Através de cálculos obtiveram-se os valores de potência e eficiência
do sistema e a potência hidráulica. O solstício de inverno apresentou eficiência
de 9,58% com bombeamento diário de 2.056,44 litros, enquanto que o solstício
de verão apresentou eficiência de 9,07% com bombeamento diário de 2.377,21
litros. A maior eficiência nos dias de inverno está atrelada às menores
temperaturas nestes dias se comparado aos dias de verão e o fator que
provocou uma maior vazão de água bombeada nos dias de verão está ligado
ao tempo de insolação solar que é maior se comparado aos dias de inverno. O
total de água bombeada durante o período do experimento foi de 435.042,20
litros.
|
55 |
Sistemas de bombeamento de água com velocidade de rotação variávelKuritza, Jóice Cristini January 2017 (has links)
O consumo de energia dispendido pelos sistemas de bombeamento apresenta valores elevados e que podem onerar a operação dos sistemas de abastecimento de água realizada pelas companhias de saneamento. Assim, esta pesquisa está centrada no desenvolvimento de uma metodologia para análise da eficiência energética desses sistemas. O procedimento metodológico foi desenvolvido para uma tipologia genérica de sistema composta de dois reservatórios, inferior e superior, um conjunto motobomba e uma adutora, responsável pelo transporte de água entre eles. Foram avaliadas 96 possibilidades geométricas para esse sistema, formadas a partir da combinação de diferentes alturas geométricas, comprimentos e diâmetros da linha adutora. Ainda, foram estudados três formatos de curva, com quatro volumes de consumo diário distintos, em duas situações, início e fim de projeto. O algoritmo Shuffled Complex Evolution – SCE-UA foi empregado para obter a regra de operação otimizada do sistema de bombeamento e a função-objetivo foi formulada para representar os custos de energia para 20 anos de operação somado aos custos de instalação do sistema de bombeamento (adutora, reservatório superior e conjunto motobomba). Além disso, foram calculados índices e indicadores para facilitar o entendimento e a avaliação da eficiência energética de sistemas de bombeamento. A partir da análise dos resultados dos sistemas cuja operação foi otimizada, e dos resultados dos índices e indicadores, foram estabelecidos critérios e equações que podem ser utilizados para análise da operação, dimensionamento e eficiência energética de sistemas de bombeamento de água. Também, foi desenvolvida uma metodologia para a estimativa da energia mínima que um sistema de bombeamento pode consumir se todos os critérios de eficiência energética forem satisfeitos, ou seja, quando todas as grandezas que compõem o cálculo da energia forem determinadas a partir de critérios otimizados. Essa metodologia foi aplicada em dois cenários: projetos de sistemas de bombeamento de água e diagnóstico de sistemas de bombeamento de água existentes. Na primeira abordagem, o indicador se mostrou útil para inferir sobre consumo de energia e, inclusive, definir o diâmetro ótimo da linha adutora com maior ponderação. Já na segunda abordagem, o indicador tem potencial para ser utilizado na definição da linha de base do sistema e pode auxiliar a tomada de decisão e gestão hidroenergética desses sistemas. / The energy consumed by the pumping systems has high values and can overload the operation of the water supply systems carried out by the sanitation companies. Thus, this research is focused on the development of a methodology to analyze the energy efficiency of these systems. The methodological procedure was developed for a generic system composed of two reservoirs, upper and lower, pumping system and a pipeline, responsible for transporting water between the reservoirs. It was evaluated 96 geometric possibilities for this system, formed from the combination of different static heights, lengths and diameters of the pipeline. Also, three curve formats were studied, with four distinct daily consumption volumes, in two situations, beginning and end of the project. The Shuffled Complex Evolution (SCE-UA) algorithm was employed to obtain the optimal operating rule for the pumping system and the objective function was formulated to represent the energy costs for 20 years of operation plus the pumping system installation costs (pipeline, upper reservoir and pumping system). In addition, indexes and indicators were calculated to facilitate the understanding and evaluation of the energy efficiency of pumping systems. Based on the analysis of the results of the systems whose operation was optimized, and the results of indexes and indicators, criteria and equations were established that can be used to analyze the operation, design and energy efficiency of water pumping systems. Also, a methodology was developed to estimate the minimum energy that a pumping system can consume if all the energy efficiency criteria are met, that is, when all the quantities that compose the energy calculation are determined from optimized criteria. This methodology was applied in two scenarios: projects of water pumping systems and diagnosis of existing water pumping systems. In the first approach, the indicator was useful to infer about energy consumption and, even, to define the optimum diameter of the most heavily weighted pipeline. In the second approach, the indicator has the potential to be used in the definition of the baseline of the system and may help decision making and hydropower management of these systems.
|
56 |
[en] NUMERICAL SIMULATION OF A GAS-LIQUID MIXER FOR PUMPING STATIONS / [pt] SIMULAÇÃO NUMÉRICA DE UM MISTURADOR GÁS-LÍQUIDO PARA ESTAÇÕES DE BOMBEIOLEONARDO CHAGAS CARBONE 26 January 2016 (has links)
[pt] A produção de petróleo offshore tem requerido cada vez mais a utilização de equipamentos de bombeio no leito marinho para a produção de poços a longas distâncias das unidades de produção. A grande maioria destes equipamentos tem dificuldade de operar com a presença de gás, ainda mais em condições de golfadas, onde a fração de vazio na sucção pode variar significativamente. Isto limita enormemente a janela operacional dos equipamentos. Uma forma de minimizar os efeitos das golfadas e, assim, ampliar a janela de operação destes equipamentos é a instalação de misturadores de fluxo na sucção das bombas, que atuam de forma a garantir uma maior sobrevida ao equipamento. Portanto, o projeto e a previsão do comportamento deste tipo de equipamento são fundamentais para bom funcionamento dos sistemas de bombeamento submarino. O presente trabalho investiga numericamente, com o modelo de dois fluidos, a eficiência de um tipo de misturador em uniformizar as frações de vazio. Diferentes configurações geométricas são analisadas e a influência das vazões de admissão de ambas as fases é discutida. A metodologia é validada através da comparação da queda de pressão através do misturador com dados experimentais disponíveis, onde se observou boa concordância. O modelo numérico mostra ainda que uma reserva de líquido é mantida no interior do equipamento e, o gás é forçado a se dispersar na corrente de líquido para sair do misturador. O comportamento do misturador frente à presença de golfadas também é investigado. Ao final do trabalho é proposta uma nova geometria, que se mostra mais tolerante a intermitências no escoamento. / [en] The offshore oil production is increasingly using pumping equipment at the seabed for production of wells at long distances from production units. Most of these devices have difficulty to operate in the presence of gas, especially in slug flow conditions, where the pump suction s void fraction can vary significantly. This problem limits the equipment s range of operation. One way to minimize the effects of slugging and thus enlarge the operation range of these devices is to use flow mixers at the pump s suction, which helps to ensure the operation even in the presence of large gas bubbles. Therefore, the design and prediction of the behavior of this type of equipment are essential for proper operation of subsea pumping systems. At the present work, the efficiency of a type of flow mixer to provide uniform void fractions at its outlet is numerically investigated, with the two fluid model. Different geometric configurations are analyzed and the influence of intake flow of both phases is discussed. The methodology is validated through comparison of the pressure drop through the flow mixer with available experimental data, where good agreement was observed. The numerical model also shows that a buffer of liquid is maintained inside the equipment and the gas is forced to disperse in the liquid stream to exit the mixer. The mixer s behavior in the presence of slugs is also investigated. Finally, a new geometry is proposed, which seems to be more efficient to avoid flow s intermittencies.
|
57 |
A difusão do acesso à água com sistemas fotovoltaicos de bombeamento no semiárido brasileiroMorais, Albemerc Moura de January 2015 (has links)
Orientador: Prof. Dr. Federico Bernardino Morante Trigoso / Tese ( doutorado)- Universidade Federal do ABC. Programa de Pós-Graduação em Energia, 2015. / Várias são as soluções tecnológicas disponíveis para o acesso à água no meio rural. Dentre elas, a opção fotovoltaica apresenta-se consolidada e competitiva, podendo suprir a demanda de água em comunidades rurais dispersas. Contudo, experiências ao redor do mundo demonstram que muitos empreendimentos têm falhado por não considerarem as peculiaridades locais e os processos adequados de introdução e manutenção da nova tecnologia. Dessa forma, por meio desta pesquisa, pretendeu-se identificar os principais entraves ao sucesso de empreendimentos de abastecimento de água em regiões semiáridas baseados na tecnologia solar fotovoltaica e recomendar formas para a superação de tais entraves de acordo com boas práticas na implantação e gestão desses sistemas. Nesse contexto, foi proposto um indicativo de política pública para potencializar a difusão e inserção tecnológica da opção fotovoltaica de bombeamento no Território Vale do Rio Canindé, semiárido piauiense. Verificou-se, nesse cenário, que para possibilitar a difusão do uso da tecnologia solar fotovoltaica nesse território é necessário inicialmente o desenvolvimento de um programa de capacitação e formação de mão de obra especializada, bem como a realização de um amplo programa governamental de incentivo que possibilite o aproveitamento do leque de instituições existentes e as potencialidades produtivas locais. / Several technological solutions exist to access to provide water in rural areas. Among them, the photovoltaic option is competitive and consolidated option to supply the demand for water in remote rural communities. However, experiences around the world show that many projects have failed by not considering the local peculiarities and adequate procedures of introduction and maintenance of the new technology. Thus, through this research, we intend to identify the main barriers to the success of water supply projects in semi-arid regions based on solar photovoltaic technology, and recommend ways to overcome these barriers in accordance with best practices in the implementation and management of systems. In this context, a suggestion of public policy is proposed to enhance the dissemination and technological integration of photovoltaic pumping option in the Caninde River Valley, Piauí semiarid. It was found, in this scenario, that to enable the widespread use of photovoltaic solar technology in this area is necessary, as a first step, the development of a training program and training skill labor, as well as the implementation of a governments program of incentives that would enable the use of the range of the existing institutions and the local productive potential.
|
58 |
Sistema inteligente para o controle de pressão De redes de distribuição de água abastecidas Por bombas associadas em paraleloBarros Filho, Emânuel Guerra de 05 December 2016 (has links)
Submitted by Maike Costa (maiksebas@gmail.com) on 2017-05-26T11:40:16Z
No. of bitstreams: 1
arquivototal.pdf: 8290765 bytes, checksum: 60cc04d99eb6779eb21f6ce5385803d1 (MD5) / Made available in DSpace on 2017-05-26T11:40:17Z (GMT). No. of bitstreams: 1
arquivototal.pdf: 8290765 bytes, checksum: 60cc04d99eb6779eb21f6ce5385803d1 (MD5)
Previous issue date: 2016-12-05 / The objective of this research is to develop an intelligent system based on artificial neural
networks for water distribution systems that operate with pumps associated in parallel. The
system aims at process automation and the definition of operating state for electric motors
(on, off or with partial rotation), aiming at the same time the pressure control and reduction of
electric power consumption. The developed intelligent system is a generic one, which allows
the application of control structure in similar processes, and it was applied in a fully
instrumented test rig that emulates a real system of water supply. The results showed that the
performance of the artificial neural network is quite satisfactory, and thus can be successfully
implemented in other similar water distribution systems in order to reduce consumption of
water and electric energy, decrease costs of maintenance, and increase the degree of reliability
of operational procedures. / O objetivo desta pesquisa é desenvolver um sistema inteligente baseado em redes neurais
artificiais para redes de distribuição de água que operam com bombas associadas em paralelo.
O sistema tem por finalidade a automação do processo e a definição do estado de
funcionamento dos motores elétricos (ligado, desligado ou com rotação parcial), visando
simultaneamente ao controle de pressão e à redução do consumo de energia elétrica. O
sistema inteligente desenvolvido é genérico, o que permite a aplicação da estrutura de
controle em processos semelhantes, e foi aplicado em uma bancada experimental totalmente
instrumentalizada que emula um sistema real de abastecimento de água. Os resultados
mostraram que o desempenho da rede neural artificial é bastante satisfatório, e, assim, poderá
ser implementada com sucesso em outros sistemas de distribuição de água similares, a fim de
proporcionar redução do consumo de água e energia elétrica, diminuição dos custos de
manutenção e aumento do grau de confiabilidade dos procedimentos operacionais.
|
59 |
Controle para bombeamento distribuído com vistas à minimização dos custos energéticos aplicado a sistemas de abastecimento de água / Distributed control for pumping with a view to minimizing costs of energy applied to water supply systemsCarvalho, Paulo Sergio Oliveira de 20 June 2012 (has links)
Made available in DSpace on 2015-05-08T14:59:42Z (GMT). No. of bitstreams: 1
arquivototal.pdf: 5430085 bytes, checksum: 2ce42198a2dd4ca16f3d08b584e0513c (MD5)
Previous issue date: 2012-06-20 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The objective of this research was to develop a nonlinear controller, using the technique of
fuzzy intelligent control, apply to networks pressurized water distribution sectored,
automated and distributed pumping system in order to minimize energy consumption. The
methodology used was based on the performance of several tests using an instrumented
experimental network, where the control system can be tested and evaluated. The
experimental system has pressure transducers and flow, variable speed driven, proportional
control valves and water distribution lines, with different topologies that allow you to
simulate dynamically different situations operational supply network, depending on the
variation of demand water over time. The supervisory system built acquires the necessary
data, provided by the network monitoring tools. The controller module of the supervisory
system processes data in real time, tuning the instruments to carefully control the
experimental network. We performed numerous tests with different operating conditions in
order to extract rules and various combinations of control, to optimize the balance of
pressures on the network and reduce energy consumption. The results obtained proved that
it is more economical to operate the network with the two sets of pumping, for all ranges of
consumption studied. Besides the economic aspect, which indicated an energy saving of
around 12.17%, the controller gave better performance to achieve and balance the
pressures of the network with the pumping action of two acting simultaneously. / O objetivo nesta pesquisa foi desenvolver um controlador não-linear, utilizando a técnica
de controle inteligente fuzzy, aplicável a redes pressurizadas de distribuição de água
setorizadas, automatizadas e com sistema de bombeamento distribuído, visando minimizar
o consumo de energia elétrica. A metodologia empregada foi baseada na realização de
diversos ensaios utilizando uma rede experimental instrumentalizada, onde o sistema de
controle pode ser testado e avaliado. O sistema experimental possui transdutores de
pressão e de vazão, conversores de frequência, válvulas com controle proporcional e
ramais de distribuição de água, com topologias diferentes que permitem simular,
dinamicamente, diversas situações operacionais da rede de abastecimento, em função da
variação da demanda de água ao longo do tempo. O sistema supervisório construído
adquire os dados necessários, fornecidos pelos instrumentos de monitoramento da rede. O
módulo controlador do sistema supervisório processa os dados, em tempo real,
sintonizando de forma criteriosa os instrumentos de controle da rede experimental. Foram
realizados inúmeros ensaios com diferentes condições operacionais, visando extrair regras
e combinações diversas de controle, para otimizar o equilíbrio das pressões na rede e
reduzir o consumo energético. Os resultados obtidos comprovaram que é mais econômico
operar a rede com os dois conjuntos de bombeamento, para todas as faixas de consumo
estudadas. Além do aspecto econômico, que indicou uma economia de energia da ordem
de 12,17%, o controlador proporcionou um melhor desempenho para atingir e equilibrar as
pressões da rede com a ação dos dois bombeamentos atuando simultaneamente.
|
60 |
Potencial energético de um sistema de bombeamento de água via membrana de microfiltração. / Potential energy of a water pumping system via membrane microfiltrationSILVA, Robson Rogaciano Fernandes da. 20 April 2018 (has links)
Submitted by Jesiel Ferreira Gomes (jesielgomes@ufcg.edu.br) on 2018-04-20T19:47:10Z
No. of bitstreams: 1
ROBSON ROGACIANO FERNANDES DA SILVA – DISSERTAÇÃO (PPGEQ) 2015.pdf: 2972393 bytes, checksum: 0382c6be9c4c653ce0885143a6cf932d (MD5) / Made available in DSpace on 2018-04-20T19:47:10Z (GMT). No. of bitstreams: 1
ROBSON ROGACIANO FERNANDES DA SILVA – DISSERTAÇÃO (PPGEQ) 2015.pdf: 2972393 bytes, checksum: 0382c6be9c4c653ce0885143a6cf932d (MD5)
Previous issue date: 2014-03 / Capes / Este trabalho trata do estudo da potencialidade energética de geradores fotovoltaicos em acionar um sistema de bombeamento de água via processo de microfiltração. A avaliação do sistema permitiu caracterizar o efeito da disponibilidade de potencia elétrica e da pressão de operação do sistema, para
determinação da quantidade de água produzida. Na avaliação do sistema, foi
utilizada uma alimentação de água da Cisterna do LABDES (água da chuva captada pelas telhas), fazendo uso de um Motor Bomba Centrifuga de potê ncia de 0,5 Hp, e atuando com variações de pressões entre 0 a 2 kgf/cm². Inicialmente, foi realizada a
caracterização do sistema, através de sua operação com disponibilidade de potência
elétrica variável (Energia convencional), sendo verificado seu perfil de funcionamento a partir da avaliação dos seguintes parâmetros: vazão do permeado, Pressão, Potência e remoção de cor e turbidez. A avaliação do sistema, permitiu caracterizar o efeito da disponibilidade de potência elétrica e da pressão de
operação do sistema na quantificação e qualidade da água produzida. Utilizando os
dados do potencial solarimétrico (LEIAM-UFCG) da cidade de Campina Grande – PB, para o período de Outubro/2013 à Setembro/2014, realizou-se um estudo da oferta de energia solar disponibilizada para o período especificado, onde verificou-se
que 70,5% da irradiação média mensal encontra-se na faixa entre 200 e 1400 W/m².
Posteriormente, avaliou-se o funcionamento do sistema operando efetivamente com
energia solar fotovoltaica, o qual atingiu uma produção média de 0,36 L/min ou 174,4 L/dia (média dos Dias 1,Dias 2 e Dias 3), durante 8 horas de funcionamento do sistema por dia. Com uma pressão média de operação de 0,99 kgf/cm² durante os 3 dias. / This work deals with the study of the effectiveness of photovoltaic generators drive a via microfiltration water pumping system. The rating system allows to characterize the effect of the availability of electric power and operation of the system pressure to
determine the amount of water produced. In the evaluation system used was a
cistern of the water supply LABDES (rainwater captured by tile), using a 0.5 hp motor pump power centrifuged, and the variations in operating pressures from 0 to 2 kgf/cm2. Initially the system characterization was performed by means of operation with
variable availability of electrical power (conventional Energy), confirmed its working
profile from the evaluation parameters: permeate flow, pressure, power and removing
color and turbidity. The rating system allowed us to characterize the effect of the availability and the electrical power system operating pressure in the quantity and quality of water produced. Using potential data solarimetric (read-UFCG) of Campina
Grande - PB for the period October / 2013 to September / 2014, there was a study of
solar energy supply available for the specified period, where it was found that 70.5% of the monthly average irradiation is between 200 and 1400 W / m2. Subsequently, we evaluated the system works effectively operating with photovoltaic solar energy, which reached an average production of 0.36 L / min or 174.4 L / day (mean of Days
1, 2 Days and Days 3) for 8 hours of operation of the system per day, with an average operating pressure of 0.99 kgf / cm² for 3 days.
|