• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 301
  • 56
  • 10
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 425
  • 425
  • 230
  • 136
  • 95
  • 94
  • 92
  • 84
  • 78
  • 75
  • 71
  • 71
  • 71
  • 62
  • 51
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
281

Resistência ao cisalhamento de selante associado a dois sistemas adesivos, após contaminação salivar: influência da fotopolimerização individual e simultânea / Shear bond strength of a pit-and-fissure sealant associated with two adhesive systems after salivary contamination: influence of individual and simultaneous light curing

Silva, Jaciara Miranda Gomes da 06 August 2007 (has links)
Este trabalho teve por objetivo avaliar \"in vitro\" a resistência ao cisalhamento de um selante resinoso (Fluroshield - F) em associação com um sistema adesivo total-etch (Adper Single Bond 2-SB) e um self-etching (Clearfil S3 Bond-S3) em condições de contaminação salivar, comparando dois protocolos de fotopolimerização: individual do sistema adesivo e, em seguida, do selante ou simultânea de ambos materiais conjuntamente. Superfícies mesiais e distais de 45 terceiros molares humanos hígidos foram incluídas e planificadas, o sítio de adesão delimitado (Ø 3mm) e os corpos-de-prova alocados aleatoriamente em 6 grupos experimentais (n=15), de acordo com o tratamento empregado: I- F aplicado sobre o esmalte condicionado com ácido fosfórico a 37% (controle). Os demais grupos foram contaminados com saliva (0,01ml por 10 s) e a seguir foram aplicados: II- SB e F fotopolimerizados separadamente; III- SB e F fotopolimerizados conjuntamente; IVS3 e F fotopolimerizados separadamente; V- S3 e F fotopolimerizados simultaneamente; VI- F aplicado sem associação com adesivos sobre o esmalte condicionado e contaminado. A seguir, um cilindro de selante foi confeccionado com o auxílio de uma mesa metálica e de matriz de teflon bipartida sobre o sítio de adesão. Após armazenamento durante 24 horas a 37°C em água destilada, os espécimes foram submetidos ao teste de resistência ao cisalhamento em Máquina de Ensaios Universal (0,5mm/min; 50Kgf). As interfaces adesivas foram analisadas quanto ao tipo de fratura em microscópio óptico com 20x de aumento e para análise qualitativa, três espécimes de cada grupo, foram selecionados e analisados em microscópio eletrônico de varredura. As médias obtidas, em MPa, e os desvios padrão foram: I-12,28 (±4,29); II-8,57 (±3,19); III-7,97 (±2,16); IV-12,56 (±3,11); V- 11,45 (±3,77); e VI-7,47 (±1,99). A análise estatística, por meio da Análise de Variância e teste de Fisher, demonstrou que a contaminação salivar afetou negativamente a resistência adesiva. A associação do sistema adesivo self-etching ao selante resultou em uma média semelhante estatisticamente ao grupo controle. Comparando os protocolos de fotopolimerização, não houve diferença estatisticamente significante entre os grupos nos quais foi realizada a fotopolimerização simultânea ou individual dos materiais. Com base nestes resultados pôde-se concluir que o protocolo de fotopolimerização não afetou os valores de resistência adesiva ao esmalte condicionado e contaminado. A associação do sistema adesivo self-etching Clearfil S3 Bond ao selante Fluroshield aumentou a resistência ao cisalhamento com diferença estastísticamente significante em relação aos grupos nos quais foi utilizado o sistema adesivo Adper Single Bond 2 e com valor médio semelhante ao grupo controle, no qual o selante foi aplicado em condições ideais, na ausência de contaminação salivar. / The purpose of this study was to evaluate in vitro the shear bond strength of a resin-based pit-and-fissure sealant (Fluroshield - F) associated with a total-etch (Adper Single Bond 2 - SB) and a self-etching adhesive system (Clearfil S3 Bond - S3) under conditions of salivary contamination, comparing two curing protocols: individual light curing of the adhesive system and the sealant or simultaneous curing of both materials. Mesial and distal surfaces from 45 sound third molars were embedded, flattened and a 3-mm-diameter bonding site was demarcated. The specimens were randomly assigned to 6 experimental groups (n=15), according to the bonding technique: I - F was applied to the enamel etched with 37% phosphoric acid. The other groups were contaminated with saliva (0.01 mL during 10 s). II - SB and F were light cured separately; III - SB and F were light cured together; IV - 3S and F were light cured separately; V - 3S and F were light cured simultaneously; VI - F was applied to salivary-contaminated etched enamel without an intermediate bonding agent layer. Thereafter, a sealant cylinder was fabricated using a metallic clamping device and a split Teflon matrix placed over the bonding site. After 24-hour storage in distilled water at 37°C, shear bond strength was measured using a knifeedge blade in a universal testing machine (0.5 mm/mm; 50 kgf). The debonded interfaces were examined with an optical microscope to determine the failure modes. For a qualitative analysis, 3 specimens from each group were selected and observed under scanning electron microscopy. Means (±SD) in MPa were: I-12,28 (±4,29); II 8,57 (±3,19); III-7,97 (±2,16); IV-12,56 (±3,11); V-11,45 (±3,77); and VI-7,47 (±1,99). Statistical analysis by ANOVA and Fisher\'s test showed that salivary contamination affected negatively the bond strength. The association between the self-etching adhesive system and sealant yielded bond strength mean statistically similar to that of the control group. Comparing the curing protocols, there was no statistically significant difference between the groups with simultaneous or individual light curing of the materials. Based on these results, it may be concluded that the curing protocol did not affect the bond strength to the contaminated etched enamel. The association of Clearfil S3 Bond self-etching adhesive system to Fluroshield sealant increased the shear bond strength with statistically significant difference from the groups with Adper Single Bond 2 adhesive system, and showing mean value similar to that of the control group, in which the sealant was applied under ideal conditions, without salivary contamination.
282

Efeito da contaminação por saliva humana na interface adesiva: resistência de união, análise de camada híbrida e conversão de sistemas adesivos / Effect of human saliva contamination on adhesive interface: bond strength, hybrid layer analysis and conversion of adhesive systems

Villavicencio Espinoza, Carlos Andres 03 July 2017 (has links)
Este estudo teve como objetivo analisar o efeito da contaminação por saliva humana na resistência de união (RU) da interface adesiva em dentina por microtração, nas características morfológicas da camada híbrida (CH) em microscopia confocal e no grau de conversão (GC) de 2 sistemas adesivos: Adper Single bond 2 (SB) e Single Bond® Universal (SU). Cento e oitenta dentes terceiros humanos hígidos foram divididos em 12 grupos (n=10), de acordo com o sistema adesivo utilizado, a presença de saliva e o tempo de armazenagem. Após o procedimento adesivo e aplicação da resina composta Filtek Z250, os dentes foram mantidos em água destilada em estufa a 37°C por 48 horas, 6 meses ou 12 meses antes de serem seccionados em palitos (0,8mm x 0,8mm, aproximadamente) para serem levados à máquina de ensaios universal Instron para os testes de microtração. Para à análise da interface adesiva em microscopia confocal de varredura a laser para verificação e mensuração de alterações internas na interface foram utilizados 60 dentes divididos em 6 grupos (n=10) de acordo com os tempos de 48 horas, 6 meses, e 12 meses respectivamente, empregando os sistemas adesivos (SB) e (SU). O efeito da presença de saliva também foi avaliado pelo grau de conversão dos adesivos, empregando-se espectroscopia de infravermelho transformada de Fourier empregando os sistema adesivos (SB) e (SU) com incorporação de saliva humana na sua composição (n=5) com concentrações 10%, 25% e 50% em vol. Para a comparação das variáveis: RU, (GC), espessura da CH, na presença de saliva e tempo de armazenamento foram utilizados os testes de Análise de Variância a três critérios e de comparações múltiplas de Tukey (p<0,05). Os valores de RU (MPa±dp: 48horas/6meses/1ano) foram: SB (43,53 ±6,0; 40,10±3,4; 38,59±5,4); SalSB (43,09±6,2; 39,86±6,6; 37,255,8); SU (42,98±4,3; 39,30±3,6; 40,44±5,7); Sal SU (44,39±4,2; 42,26±2,5; 38,26±5,7). Os Valores médios da CH (MPa±dp: 48horas/6meses/1ano) foram: SalSB (3,59±0,8; 3,59±1,0; 2,08±1,5). SalSU (1,26±0,5; 1,73±0,8; 1,07±0,3). Os valores de GC (MPa±dp: 10%/25%/50%vol) foram: SB (85,59±3,4; 49,68±12,8; 38,56±11,8); SU (85,52±3,3; 86,27±3,5; 57,82±11,1).Conclui-se, portanto, que a contaminação por saliva humana não interferiu na RU da interface dentina/resina composta após 48 horas, 6 meses e 12 meses. A morfologia da camada hibrida foi alterada pela presença da saliva nos períodos 6 e 12 meses,. O GC dos sistemas adesivos foi afetado pela presença de saliva após a polimerização imediata. Entretanto o fator tempo foi determinante para a deformação da interface dentina/resina para ambos os sistemas adesivos. / The objective of this study was to analyze the effect of human saliva contamination on bond strength of the dentin/adhesive interface, morphology of the hybrid layer by confocal microscopy and SEM analysis and degree of conversion of 2 adhesive systems: Adper Single bond 2 (SB) and Single Bond® Universal ( SU). One hundred and eighty healthy human third teeth were divided into 12 groups (n = 10), according to the adhesive system used, the presence of saliva and the storage time. After the adhesive procedure and placement of resin composite (Filtek Z250), the teeth were stored in distilled waterat 37 ° C for 48 hours, 6 months or 12 months before being cut into sticks (0.8mm x 0.8mm, approximately) to the microtensile strength tests. For the analysis of the adhesive interface in confocal microscopy of laser scanning for verification and measurement of internal interface changes, 60 teeth were used divided into 6 groups (n = 10) according to the storage time: 48 hours, 6 months, and 12 monthsand (SB) and (SU). The effect of the presence of saliva was also evaluated by the degree of conversion of the adhesives using Fourier transform infrared spectroscopy employing adhesive (SB) and (SU) systems incorporating human saliva in its composition (n = 5) with 10%, 25% and 50% vol. For the comparison of the variables: bond strength, degree of conversion, and hybrid layer thickness in the presence of saliva and storage time, the three criteria Variance Analysis and Tukey multiple comparisons tests (p <0.05) were used. The values of bond strength (MPa ± dp: 48hours / 6meses / year) were: SB (43.53 ± 6.0, 40.10 ± 3.4, 38.59 ± 5.4); SalSB (43.09 ± 6.2, 39.86 ± 6.6, 37.255.8); SU (42.98 ± 4.3, 39.30 ± 3.6, 40.44 ± 5.7); SU salt (44.39 ± 4.2, 42.26 ± 2.5, 38.26 ± 5.7). The mean values of hybrid layer thickness (MPa ± dp: 48hours / 6meses / year) were: SalSB (3.59 ± 0.8, 3.59 ± 1.0, 2.08 ± 1.5). SalSU (1.26 ± 0.5, 1.73 ± 0.8, 1.07 ± 0.3). The values of degree of conversion (MPa ± dp: 10% / 25% / 50% vol) were: SB (85.59 ± 3.4, 49.68 ± 12.8, 38.56 ± 11.8); (85.52 ± 3.3, 86.27 ± 3.5, 57.82 ± 11.1). It was therefore concluded that human saliva contamination did not interfere on bond strength of the dentin/adhesive interface after 48 hours, 6 months and 12 months. The morphology of the hybrid layer was altered by the presence of saliva after 6 and 12 months. The degree of conversion of adhesive systems was affected by the presence of saliva immediately after polymerization. However, the time factor was determinant for the dentine/resin interface deformation for both adhesive systems.
283

Efeito da atmosfera de sinterização na resistência de união da porcelana com ligas de níquel-cromo e cobalto-cromo / Effect of firing atmosphere on metal ceramic bond strength of nickel-chromium and cobalt-chromium

Alves, Luciana Mara Negrão 11 February 2015 (has links)
O objetivo deste trabalho foi avaliar a influência de dois diferentes ambientes de sinterização (vácuo e argônio) sobre a resistência da união metaloceramica (RUMC) envolvendo diferentes ligas de metais básicos (Co-Cr e Ni-Cr) e uma porcelana odontológica, através do teste de flexão de três pontos, conforme preconizado pela ISO 9693:2012. As ligas estudadas foram Co-Cr: Remanium e Keragen e Ni-Cr: Verabond II e uma liga experimental &ldquo;SR&rdquo; . Foram obtidos 80 corpos de prova em forma tiras metálicas medindo 25 X 0,5 X 5 mm. Para esse ensaio, portanto, o número de corpos de prova foi o produto de 4 ligas x 2 condições de atmosfera de sinterização x 10 repetições. A parte metálica de todos os corpos de prova após a fundição foram usinados e jateados com óxido de alumínio (150&mu;m) e a seguir tratados como preconizado pelo fabricante. O corpo cerâmico, com o auxílio de uma matriz, foi confeccionado na área central da tira, 8,0 X 3,0mm, apresentando 1,1mm de espessura, sendo 10 corpos de prova em cada ambiente de sinterização para cada tipo de liga. Os corpos de prova obtidos foram submetidos aos testes de flexão de três pontos na Máquina de Ensaios Mecânicos (EMIC) com velocidade de 1.0mm/min. para determinação da RUMC. Os valores da carga de ruptura obtidos em quilograma-força (Kgf) foram convertidos para Newton (N) e a partir disso foi calculado o valor da RUMC para cada corpo de prova, considerando o coeficiente de elasticidade de cada liga e a espessura exata de cada corpo de prova. Os dados obtidos (MPa) foram submetidos à análise estatística (ANOVA) e Bonferroni. A Análise de Variância indicou diferença estatisticamente significante para os fatores de variação ambiente (P=0,00), liga (P=0,009) e entre as interações ambiente de sinterização e liga (P=0,000). Na sinterização a vácuo as ligas Keragen, SR e Verabond II apresentaram maiores valores de RUMC do que o argônio. Para a liga Remanium, não houve diferença entre a sinterização em argônio e a sinterização a vácuo. Dentre os grupos sinterizados no argônio não houve diferença estatisticamente significante entre as ligas. Entretanto, no vácuo a liga Remanium apresentou menor valor de RUMC do que as demais ligas, que não apresentaram diferença entre si. Os corpos de prova, após os ensaios de flexão, foram submetidos a análise em microscopia optica, MEV e EDS para avaliar e registrar tipo de falha que sofreram. De acordo com a MO, houve predomínio de fraturas mistas. Os corpos de prova de Co-Cr (Remanium e Keragen), independende do ambiente de sinterização, apresentaram uma fina camada de óxido no corpo cerâmico, o que foi comprovado pelo EDS, com maior presença de íons Cr nessas regiões, já os grupos SR e Verabond II, apresentaram maior quantidade de opaco aderido em suas tiras metálicas. A MEV comprovou os achados da MO, onde foi possível encontrar grandes ilhas de material cerâmico nas ligas de Ni-Cr. A sinterização em argônio influenciou negativamente a RUMC dos pares metalocerâmicos confeccionados em Ni-Cr e na liga Keragem / The aim of this study was to evaluate the influence of two different firing atmosphere (vacuum and argon) on the metalceramic bond strength (MCBS) involving different base metal alloys (Co-Cr and Ni-Cr) and a dental porcelain through three-point bending test, as recommended by ISO 9693: 2012. Co-Cr alloys studied were: Remanium and Keragen and Ni-Cr: Verabond II and an experimental alloy \"SR\". 80 specimens were obtained in metallic form strips measuring 25X0.5 X 5.0 mm. For this test, therefore, the number of specimens was the product of 4 x 2 alloy sintering atmosphere conditions x 10 replicates. The metal portion of all specimens were machined after casting and sandblasted with aluminum oxide (100&mu;m) and then treated as recommended by the manufacturer. By using a matrix, the ceramic body was made in the central area of the strip, 8.0 x 3.0 mm, it was made 1.1 mm thickness, 10 specimens in each sintering environment for each type of alloy. The specimens obtained were tested for three-point bending in a universal testing machine with a speed of 1.0mm / min. to determine MCBS. The values of the tensile strength obtained in kilogramforce (kgf) were converted into Newton (N) and from this the value of MCBS for each specimen was calculated, considering the coefficient of elasticity of each league and the exact thickness of each specimen. The data (MPa) were subjected to statistical analysis (ANOVA) and Bonferroni. The analysis of variance indicated statistically significant difference for the environment factors of firing atmosphere (P = 0.00) and alloy (P = 0.009). There was a statistically significant difference in the interaction factors for firing atmosphere x alloy (P = 0.000). In the vacuum Keragen, SR and Verabond II alloys showed higher MCBS than argon. To Remanium, there was no difference between the sintering in argon and vacuum. Among the groups sintered in argon there was no statistically significant difference between the alloys. However, the vacuum Remanium showed the lowest RUMC than other alloys, which showed no difference between them. The specimens after the bending tests, were subjected to analysis in optical microscopy, SEM and EDS to assess and record type of failure they suffered. According to the MO was predominantly mixed fractures. Specimens of Co-Cr (Remanium and Keragen) independende the atmosphere firing, showed a thin oxide layer on the ceramic body, which was confirmed by EDS, with greater presence of Cr in these regions, since the SR groups and Verabond II, presented more opaque stuck in their metal strips. SEM confirmed the findings of MO, where it was possible to find large islands of ceramic material in Ni-Cr alloys. The sintering in argon negatively influenced MCBS metalceramic of pairs made of Ni-Cr alloy and Keragem
284

Avaliação da espessura de cimento e resistência adesiva de pinos de fibra de vidro cônicos em preparo para retentor intra-radicular realizados com uma ponta ultrassônica desenvolvida / Assessment of cement thickness and bond strength of circular fiber posts in post space preparations with an ultrasonic tip developed

Cardenas, José Edgar Valdivia 30 October 2017 (has links)
Preparos para retentores intra-radiculares mais conservadores evitam desgaste desnecessário da estrutura dentinária, requer menos cimento e podem melhorar a retenção adesiva do pino. Assim o objetivo deste estudo foi avaliar a espessura de cimento ea resistência adesiva de pinos de fibra de vidro cônicos em preparo para retentor intra-radicular realizados com uma ponta ultrassônica desenvolvida. Trinta incisivos laterais superiores foram preparados com limas reciprocantes Wave One Gold (Dentsply Sirona, Ballaigues, Suiça) e aleatoriamente divididos em 2 grupos (n=15) de acordo com a técnica de preparo para pino: grupo US foram preparados com uma ponta ultrassônica desenvolvida, e grupo WP (controle) com a broca recomendada pelo fabricante do pino. Os pinos de fibra de vidro cônicos WhitePost DC 0.5 (FGM, Joinville, SC, Brasil) foram cimentados utilizando cimento resinoso dual nos terços cervical e médio do canal radicular. Isto posto, todos os espécimes foram seccionados transversalmente em três seções (cervical, média e apical do pino) para análise da área de cimento resinoso ao redor do pino que foi calculada através do programa AutoCAD, em seguida, para avaliar a resistência adesiva, o teste de cisalhamento por extrusão foi aplicado através de uma maquina de ensaio universal numa velocidade média de 0.5 mm/min até o deslocamento do conjunto restaurador intra-radicular e o tipo de falha avaliado por estereomicroscopia. A comparação entre grupos e entre terços da área de cimento e resistência adesiva foram analisadas pelo teste t independente e Anova com Tukey; e os tipos de falha entre os grupos por Mann-Whitney, todos com nível de significância de 5%. No grupo ultrassônico foi observado a menor quantidade de cimento (p<0.05) e a resistência adesiva nos diferentes grupos e terços se manifestou maior somente no terço apical do grupo ultrassônico (p<0.05). Falha adesiva entre cimento e dentina foi a mais prevalente do terço cervical e apical do grupo US e cervical de grupo WP. Falha adesiva entre cimento e pino foi a mais prevalente nos demais terços. Conclui-se que o preparo para retentor com a ponta ultrassônica desenvolvida requer menor quantidade de cimento e influencia na melhor resistência de união no terço apical do pino de fibra de vidro. / Conservative post space preparations for intra-radicular retainers prevent unnecessary desgaste of the dentin structure, require less cement and improve bond strength of the post. The aim of this study was to evaluate the influence of resin cement thickness and bond strength of prefabricated glass fiber circular postin post space preparations with an ultrasonic tip developed. Thirtymaxillarylateral incisors were prepared with Wave One Gold reciprocating files (Dentsply Sirona, Ballaigues, Switzerland) and randomly divided into 2 groups (n=15) according to the post preparation technique: gruoup US was prepared with an ultrasonic tip developed and group WP (control) with the drill recommended by the post fabricant. Every glass fiber posts WhitePost DC 0.5 (FGM, Joinville, SC, Brazil) was cemented using dual polymerizing resin cement in the cervical and middle thirdof the root canal. After that, every specimen was sectioned transversally into three sections(cervical, middle and apical of the post) and the resin cement thickness area was calculated with AutoCAD program, the bond strength test was done with an universal testing machineat medium velocity 0.5 mm/min and the failure pattern after the test was analyzed with stereomicroscopy. Datas obtained were analyzed statistically using Student\'s t-Test, ANOVA,andTukey\'s test. The comparison of failure modes between the groups in the different thirds was done using Mann-Whitney test, All of those at a 5% significance. Ultrasonic group presented thinnest layer of cement in all thirds (p<0,05), which also obtained a higher bond strength only in apical third (p<0,05). Adhesive failurebetween cement and dentinwas the most prevalent of the cervical and apical third of G1 and cervical of G2.Adhesive failure between cement and post was the most prevalent in the others thirds. It can be concluded that the postpreparation with the ultrasonic tip developed provides a smaller thickness of resin cement that influenced thebond strength in the apical third of the glass fiber post.
285

Estudo longitudinal da resistência e qualidade de união de diferentes sistemas adesivos à dentina irradiada com laser de femtossegundos / Long term evaluation of bond strength and quality of the interface of different adhesive systems to femtosecond laser irradiated dentin

Moretto, Simone Gonçalves 17 December 2012 (has links)
Recentemente, os lasers de pulsos ultracurtos têm sido avaliados para o preparo dos tecidos duros dentais devido à sua habilidade de reduzir os efeitos térmicos resultantes da irradiação. O objetivo deste estudo foi avaliar a efetividade de união de 3 sistemas adesivos à dentina preparada com o laser de femtossegundos (10-15 s). Para isso, 60 terceiros molares foram preparados com o laser de femtossegundos (1.450 nm; 0,3W; 100.000Hz) ou ponta diamantada, divididos em 3 subgrupos (n=10) restaurados utilizando o adesivo condicione e lave de 3 passos Optibond FL (OFL; Kerr), o autocondicionante de 2 passos Clearfil SE (CSE; Kuraray) ou o autocondicionante de 1 passo G-aenial Bond (GAB; GC). Após 1 semana de armazenamento em água, os dentes foram seccionados (1,0x1,0 mm) e testados imediatamente e após 6 meses de armazenamento. Vinte e quatro amostras adicionais foram preparadas com o laser ou ponta diamantanda conforme descrito acima. Seis amostras foram seccionadas em espécimes menores e aleatoriamente preparados para observação das características morfológicas da superfície (n=3) e subsuperfície (n=3) em Microscópio Eletrônico de Varredura (MEV) (n=3) e Microscopia Eletrônica de Transmissão (MET) (n=3). As outras 18 amostras foram restauradas com os sistemas adesivos supramencionados, seccionados em espécimes menores e distribuídos para avaliação da interface adesiva em MEV (n=3) e padrão de nanoinfiltração após 1 semana (n=2) e 6 meses (n=2) em MET. O modelo linear de efeitos mistos (=0,05) revelou um efeito significante dos fatores adesivo, armazenagem e a interação preparo x armazenagem na resistência de união. Todos os adesivos apresentaram uma redução significante da resistência de união após 6 meses de armazenamento (p<0,0001) para ambos os tipos de preparo. Com relação ao sistema adesivo, a única diferença verificada foi o maior valor de resistência de união do GAB quando aplicado sobre as superfícies irradiadas (56,71±10,72 MPa) quando comparadas com as preparadas com ponta diamantada (43,14±14,93 MPa) após 1 semana de armazenamento. A análise de fratura revelou fraturas mistas, adesivas e coesivas em dentina para ambos os métodos de preparo com um discreto aumento do número de fraturas mistas após 6 meses de armazenamento exceto para o GAB, que apresentou principalmente fraturas adesivas e mistas. A análise em MEV revelou uma fina camada de debris sobre a superfície da dentina irradiada e a hibridização com todos os sistemas adesivos resultou num íntimo contado da interface adesiva com o substrato. A análise em MET da subsuperfície irradiada revelou fibrilas colágenas preservadas. A análise da interface adesiva revelou um aumento dos depósitos de prata na camada híbrida para todos os adesivos, após 6 meses de armazenamento, independentemente do tipo de preparo. Apenas o GAB apresentou maiores depósitos de prata após 1 semana de armazenamento para as superfícies preparadas com ponta diamantada. A irradiação com o laser de femtossegundos não reduziu a receptividade da dentina aos sistemas adesivos, resultando em valores de resistência de união similares aos obtidos com a ponta diamantada; além de uma ótima interação do substrato com os sistemas adesivos e deposições de prata similares àquelas obtidas com a ponta diamantada. / Recently, the applicability of ultrashort pulsed lasers has been studied for dental hard-tissue irradiation because of its reduced residual thermal damage. The aim of this study was to determine the bonding effectiveness of 3 contemporary adhesive systems to dentin prepared by femtosecond (10-15 sec) laser-irradiation. For this, 60 third molars were prepared either by the femtosecond laser (1450 nm; 0.3W; 100,000Hz) or by bur, randomly divided into 3 subgroups (n=10) and restored with a composite using either the 3-step etch-and-rinse adhesive Optibond FL (OFL; Kerr), the 2-step self-etch adhesive Clearfil SE (CSE; Kuraray) or the 1-step self-etch adhesive G-aenial Bond (GAB; GC). After 1-week water storage, the teeth were sectioned (1.0x1.0 mm) and half of the specimens were tested until failure using a micro-tensile bond-strength (TBS) approach. The other half was stored in water and tested after 6 months. Twenty-four additional dentin samples were exposed to the diamond bur and the laser, following the same abovementioned parameters. Three samples of each treatment were sectioned in smaller specimens in order to be characterized for surface (n=3) and cross-sectional morphological analysis using Scanning Electron Microscopy (SEM) (n=3) and Transmission Electron Microscopy (TEM) (n=3). The other eighteen samples were hybridized with the abovementioned adhesive systems, sectioned in smaller samples and distributed for evaluation of the interface under SEM (n=3) and nanoleakage distribution for 1 week (n=2) and 6 months (n=2) under TEM. Linear mixed effect model (=0.05) revealed a significant effect of the factors adhesive, storage and the interaction of preparation x storage on the TBS. All adhesives presented a significant reduction of the bond strength after 6-month storage (p<0.0001) for both preparation methods. Regarding the adhesive system, the only difference found was a significantly higher TBS of GAB to laser-irradiated (56.71±10.72 MPa) than to bur-cut dentin (43.14±14.93 MPa) after 1-week water storage. Fracture analysis showed mixed, adhesive and cohesive failures in dentin similarly for both preparation methods with a slightly increase of the mixed failures after 6-months water storage for OFL and CSE, but not for GAB that presented mainly adhesive and mixed failures. SEM disclosed a thin layer of debris on the laser-irradiated dentin surface and the hybridization with all adhesive systems resulted in a very tight interface. TEM analysis of the irradiated subsurface revealed collagen fibrils preserved and for the nanoleakage evaluation an increase of silver deposits at hybrid layer for all adhesives testes after 6-months water storage, irrespective of the preparation methods. Only the GAB presented great silver deposits even after 1-week water storage for the bur-cut preparation method. Femtosecond laser irradiation did not reduce the bonding receptiveness of dentin resulting in similar values obtained with the preparation by bur. Additionally it led to a great interaction with different adhesive systems and silver deposits comparable to those obtained with the bur-cut preparation method.
286

Efici?ncia dos adesivos universais e primers na ades?o ? zirc?nia

Lopes, Raquel de Oliveira 17 January 2018 (has links)
Submitted by PPG Odontologia (odontologia-pg@pucrs.br) on 2018-05-28T13:41:25Z No. of bitstreams: 1 RAQUEL_DE_OLIVEIRA_LOPES_TES.pdf: 2230148 bytes, checksum: a749d045cae0f8098669b38fe6b648b6 (MD5) / Approved for entry into archive by Caroline Xavier (caroline.xavier@pucrs.br) on 2018-06-11T18:19:23Z (GMT) No. of bitstreams: 1 RAQUEL_DE_OLIVEIRA_LOPES_TES.pdf: 2230148 bytes, checksum: a749d045cae0f8098669b38fe6b648b6 (MD5) / Made available in DSpace on 2018-06-11T18:25:33Z (GMT). No. of bitstreams: 1 RAQUEL_DE_OLIVEIRA_LOPES_TES.pdf: 2230148 bytes, checksum: a749d045cae0f8098669b38fe6b648b6 (MD5) Previous issue date: 2018-01-17 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / (Artigo Os adesivos universais s?o t?o eficientes quanto um primer para a ades?o ? zirc?nia?) O objetivo do trabalho foi comparar a resist?ncia de uni?o ? cer?mica de zirc?nia de quatro adesivos universais e um primer para zirc?nia. Setenta e cinco amostras de zirc?nia foram confeccionadas e inclu?das em resina acr?lica. A superf?cie das amostras foi polida com lixas de carbeto de sil?cio nas granula??es 600, 800 e 1.200 e jateadas com ?xido de alum?nio 50 ?m por 5 s. As amostras foram divididas aleatoriamente em cinco grupos (n=15): G1 ? Single Bond Universal (SBU); G2 ? All Bond Universal (ABU); G3 ? Peak Universal Bond (PUB); G4 ? Ambar Universal (AU) e G5 ? Z-Prime Plus (ZP). Um cone de resina composta foi constru?do, atrav?s de uma matriz, sobre o material adesivo aplicado na superf?cie das amostras. Os corpos de prova foram armazenados em ?gua destilada a 37?C por 24 h, sendo submetidos ao teste de resist?ncia de uni?o ? tra??o em m?quina de ensaio universal EMIC com velocidade de 0,5 mm/min. Os tipos de falhas foram classificados em adesiva, coesiva ou mista. Os valores de resist?ncia de uni?o foram submetidos ? an?lise de vari?ncia (ANOVA), seguido do teste de Tukey (?=0,05). M?dias de resist?ncia de uni?o (MPa) seguidas de letras distintas diferem estatisticamente entre si: G5=21,12a, G1=20,55a, G4=19,12ab, G2=14,22b, G3=8,45c. As falhas foram predominantemente mistas no G1, G4 e G5, e predominantemente adesivas no G2 e G3. Os adesivos SBU e AU obtiveram resist?ncia de uni?o compar?vel ao ZP. / (Artigo Bond to zirconia ceramic: evaluation of different primers and a universal adhesive) The aim of the study was to evaluate the effect of a universal adhesive and different primers on the bond strength to zirconia ceramic. Seventy-five zirconia ceramic samples were obtained and divided into five groups (n=15): G1 ? Scothbond Universal (SBU); G2 ? silane + SBU; G3 - Signum Zirconia Bond; G4 - Z-Prime Plus; G5 - MZ Primer. A cone of composite resin was built. The specimens were stored in 100% relative humidity with distilled water at 37?C for 48 h, and then submitted to a tensile bond strength test in a universal testing machine at a crosshead speed of 0.5 mm/min. The type of failure that occurred during the debonding procedure was analyzed. The mean results of the bond strength test (MPa) followed by the same letter represent no statistical difference by ANOVA and Tukey?s post-hoc test (p<0.05): G2=27.55a (?6.99), G4=23.71a (?5.65), G1=22.64a (?5.67), G5=13.64b (?5.49), G3=7.54c (?4.75). G2 and G4 exhibited predominantly cohesive failure in the resin composite cone. G1 and G5 had predominantly mixed failures, and G3 exhibited only adhesive failures. The SBU and Z-Prime Plus provided higher bond strength to zirconia ceramic. / (Artigo Os adesivos universais s?o t?o eficientes quanto um primer para a ades?o ? zirc?nia?) The aim of the study was to compare four universal adhesives and a primer on the bond strength to zirconia ceramic. Seventy-five zirconia ceramic samples were obtained and embedded in acrylic resin. The surface of the samples was polished with 600-, 800- and 1200-grit silicon carbide abrasive papers, and sandblasted with 50 ?m aluminum oxide particles for 5 s. The samples were divided into five groups (n=15): Single Bond Universal (SBU); G2 ? All Bond Universal (ABU); G3 ? Peak Universal Bond (PUB); G4 ? Ambar Universal (AU) e G5 ? Z-Prime Plus (ZP). A cone of composite resin was built on the adhesives and primer applied. The specimens were stored in distilled water at 37oC for 24 h, and then submitted to a tensile bond strength test in a universal testing machine at a crosshead speed of 0.5 mm/min. The type of failure that occurred during the debonding procedure was classified as adhesive, cohesive or mixed. The values of bond strength were analyzed by analysis of variance (ANOVA) followed by Tukey?s test (?=0.05). Means of bond strength (MPa) followed by the distinct letters represent statistical difference: G5=21,12a, G1=20,55a, G4=19,12ab, G2=14,22b, G3=8,45c. The failures were predominantly mixed in G1, G4 and G5, and predominantly adhesive in G2 and G3. SBU and AU adhesives obtained bond strength comparable to ZP.
287

Efeito do retardamento da polimerização da base de cimento de ionômero de vidro modificado por resina na resistência adesiva em restaurações de resina composta / Effect of delaying photoativation of resin modified glass-ionomer cement used as a liner on the bond strength of composite resin restorations

Casas Apayco, Leslie Caroll 22 April 2009 (has links)
Durante o processo inicial da reação de presa, o cimento de ionômero de vidro modificado por resina (CIVMR) apresenta baixo módulo de elasticidade, característica importante quando utilizado como base de restaurações com resina composta, por diminuir o estresse de contração de polimerização nas paredes cavitárias. O presente estudo teve como objetivo analisar a influência da técnica de polimerização de uma base CIVMR (VitrebondTM) por resina na interface dente/restauração de resina composta, através de teste de microtração e análise em microscopia confocal. Foram utilizados 30 dentes molares humanos hígidos extraídos, nos quais foram confeccionadas cavidades padronizadas em sua face oclusal (5mm de comprimento x 3mm de largura x 4,5mm profundidade). O sistema adesivo utilizado AdperTM Single Bond 2 foi marcado previamente com Rodamina B (0,16mg/ml), para possibilitar a análise em microscópio confocal. Os dentes foram divididos em 3 grupos: Grupo 1 (controle): base de CIVMR VitrebondTM + fotoativação + sistema adesivo + resina composta FiltekTM Z250; Grupo 2: base de CIVMR VitrebondTM + sistema adesivo + fotoativação por 30 segundos simultânea dos dois materiais + resina composta FiltekTM Z250; Grupo 3: base de CIVMR por resina VitrebondTM + tempo de espera de 60 segundos + fotoativação + sistema adesivo + resina composta FiltekTM Z250. Após a restauração, os dentes permaneceram em água deionizada em estufa a 37 ºC por 24 horas. Em seguida, foram seccionados com disco de diamante em fatias de aproximadamente 0,8mm no sentido vestíbulo-lingual. Uma fatia de cada dente foi separada aleatoriamente para análise da presença de fendas na interface dentina/resina composta em microscopia confocal. As demais fatias foram seccionadas para a confecção de palitos, para os testes de microtração. Os resultados de resistência de união foram submetidos à análise de variância a um critério ANOVA a 5% e teste de qui-quadrado para as variáveis de presença de fendas marginais e tipo de fratura resultante (p<0,05). Não houve diferença estatisticamente significante entre os três grupos (p=0,644) com relação à resistência adesiva e tipo de fratura, predominando a fratura do tipo adesiva para todos os grupos. Quanto à presença de fendas marginais internas, foi evidenciada sua presença nos grupos 2 e 3, sem diferença estatisticamente significante entre os três grupos testados (p=0,082). Conclui-se, portanto, que a técnica de polimerização da base de cimento de ionômero de vidro modificado por resina não influencia na resistência adesiva da interface dente/restauração de resina composta. / During the initial process of setting reaction, the resin-modified glass-ionomer cement (RMGIC) shows low modulus of elasticity, which is an important characteristic when RMGIC is used as a liner in resin composites restorations, because it decreases the polymerization shrinkage stress in cavity walls. The aim of this study was to analyze the influence of polymerization techniques of resin-modified glass-ionomer cement used as a liner on the adhesive interface dentin/resin by microtensile test and confocal microscopic analysis. Standardized occlusal cavity preparations (5mm length x 3mm wide x 4.5mm depth) were prepared in 30 human extracted molars. For the analysis at the confocal microscope, the adhesive system AdperTM Single Bond 2 was previously marked with rodhamine B (0.16mg/ml). The tooth were divided into three groups: Group 1 (control): RMGIC liner VitrebondTM + photoactivation for 30 seconds + adhesive system + resin composite Filtek TM Z250; Group 2: RMGICs liner VitrebondTM + adhesive system + simultaneous photoactivation of both materials + resin composite FiltekTM Z250; Group 3: RMGICs liner VitrebondTM+ 60 seconds delay time + photoativation for 30 seconds + adhesive system + resin composite FiltekTMZ250. Specimens were stored at 37ºC in deionized water for 24 hours. After this period, tooth was sectionated in 0.8mm slices (buco-lingual). One slice of each tooth was randomly selected for confocal microscopy for analysis of the interface resin/dentin. The other slices were sectionated in sticks (mesio-distal) for microtensile test. One-way ANOVA (p<0.05) showed no significant statistical difference among groups 1, 2 and 3 (p=0.644). Quisquare test showed no significant statistical difference of type of fracture (adhesive fracture was predominant) and presence of gap at the interface dentin/resin among groups. (p=0.082). It can be concluded, that polymerization technique of resin-modified glassionomer cement (RMGIC) did not influence bond strength and dentin/resin composite interface.
288

Efeito do ambiente de sinterização na resistência de união de cerâmicas a ligas de níquel-cromo, cobalto-cromo e titânio comercialmente puro / Effect of firing atmosphere on metal ceramic bond strength of nickelchromium, cobalt-chromium and commercially pure titanium

Rocha, Milena Teixeira da 23 November 2012 (has links)
O objetivo deste trabalho foi avaliar o efeito do ambiente de sinterização vácuo e argônio na resistência de união (RUMC) de cerâmicas às ligas de Ni-Cr (Fit Cast SB), Co-Cr (Star Loy C) e titânio comercialmente puro (Tritan). A partir de uma matriz de teflon, foram obtidos 60 padrões de resina/cera em forma de cilindro, com 8 mm de comprimento e 5 mm de diâmetro. Os padrões foram incluídos e os anéis foram levados ao forno e submetidos a ciclos térmicos para a expansão do revestimento. Em seguida, os anéis para fundição em Ni-Cr e Co-Cr foram levados à máquina de fundição por indução eletrônica. Os anéis referentes ao titânio foram levados à máquina de fundição por arco voltaico. Após resfriamento dos anéis, as fundições foram desincluídas e jateadas com óxido de alumínio (100 &mu;m). Depois de recortados dos canais de alimentação, os cilindros metálicos foram preparados para aplicação da cerâmica. Em seguida, foi realizada a aplicação e sinterização da cerâmica à vácuo ou em argônio. Para as ligas alternativas, foi utilizada a cerâmica IPS Classic V e para o titânio, a Triceram. Na sequência, os cilindros compostos pelo metal e disco cerâmico (5 mm de diâmetro e 2 mm de espessura) (n=10) foram submetidos aos ensaios de RUMC por cisalhamento na máquina de ensaios universais com célula de carga de 500 Kg e velocidade do travessão móvel de 0,5 mm/min. Após os ensaios, foram realizadas análises das fraturas por meio de microscopia óptica (MO) (15X) e microscopia eletrônica de varredura (MEV). Os dados de RUMC (MPa) obtidos foram analisados estatisticamente pelos testes ANOVA e Tukey (&alpha;=0,05). Os resultados demonstraram que a sinterização à vácuo propiciou obtenção de maiores valores (MPa) de RUMC (76,58) que a sinterização em argônio (51,31). Quanto às ligas avaliadas, as de Ni-Cr e Co-Cr apresentaram maiores valores de RUMC (71,32 e 71,28, respectivamente) que o titânio cp (49,23); sendo que entre elas não houve diferença estatística. Não houve interação entre os fatores avaliados. De acordo com a MO, houve predomínio de fraturas mistas. Segundo a MEV, os espécimes de Ni-Cr e titânio sinterizados a vácuo apresentaram maior rugosidade de superfície do que os sinterizados em argônio. Para a liga de Co-Cr não houve diferença na topografia de superfície. A sinterização em argônio influenciou negativamente a RUMC dos pares metalocerâmicos analisados. / The aim of this study was to evaluate the effect of firing atmospheres: vacuum and argon on the bond strength of ceramic to Ni-Cr (Fit Cast SB), Co-Cr (Star Loy C) and commercially pure titanium (Tritan) alloys. 60 wax/acrylic resin cylinder patterns (8 mm high and 5 mm in diameter) were prepared on a plastic custom mold for metalceramic bond strength (MCBS) test. The patterns were invested in phosphated investment and manipulated on vacuum. The rings were placed in a furnace to burn out patterns and thermally expand the molds. Then, the rings of Ni-Cr and Co-Cr were placed in an electronic machine to cast. The rings related to titanium were positioned in the casting machine with a voltaic arc. After the rings have cooled, the castings were divested manually and abraded with aluminum oxide particles (100 &mu;m). Then, the cylinders were prepared for applying of the ceramic veneering disks. The ceramic was applied and fired in vacuum and argon atmospheres. IPS-Classic ceramic was used for alternative alloys and for titanium, Triceram ceramic. Then, the cylinders composed of metal and ceramic disk (5 mm diameter and 2 mm height) (n=10) were submitted to metal-ceramic bond strength (MCBS) shear tests on an universal testing machine with load cell of 500 Kg at a crosshead speed of 0.5 mm/min. After the tests, there were made fracture analysis by optic microscopy (OM) and scanning electron microscopy (SEM). The MCBS data (MPa) were statistically analyzed by the ANOVA and Tukey test (&alpha;=0.05). The results indicated that the vacuum firing (76.58) promoted higher MCBS values than argon firing (51.31). Among the metals, Ni-Cr and Co-Cr alloys presented higher MCBS (71.32 e 71.28, respectively) than titanium (49.23); between two base alloys there was no statistical difference. There was no interaction between the evaluated factors. According to MO analysis, there was predominance of mixed fractures. According SEM, the Ni-Cr and titanium specimens submitted to vacuum presented higher surface roughness than the specimens submitted to argon. For Co-Cr, there was no difference of surface topography. The argon firing influenced negatively the MCBS of metal-ceramic evaluated pairs.
289

Efeito da radioterapia na adesão e interface ao substrato de dentes permanentes / Effect of radiotherapy on bonding and bonding interface to substrate of permanent teeth

Arid, Juliana 27 November 2015 (has links)
O câncer de cabeça e pescoço é, dentre todos os tipos de cânceres, o sétimo mais comum, dentre suas principais formas de tratamento está a radioterapia (RT), que é amplamente utilizada e eficiente, mas os efeitos colaterais aos tecidos adjacentes são inevitáveis. A realização do tratamento odontológico previamente a radioterapia é de suma importância e visa eliminar/reduzir os focos infecciosos presentes na cavidade bucal, sendo essencial a eliminação das lesões de cárie, e após a radioterapia é fundamental tratar as \"cáries de radiação\", que é um dos efeitos colaterais do tratamento radioterápico de cabeça e pescoço. Os sistemas resinosos são os materiais mais indicados para restauração dos dentes de pacientes submetidos à radioterapia, por isso o objetivo do presente estudo foi avaliar in vitro o efeito da radiação, no momento em que é realizada a restauração ao esmalte e a dentina, por meio de teste de cisalhamento, analisar longitudinalmente as alterações morfológicas na superfície do substrato dental durante a radiação por meio de microscopia confocal a laser e analisar qualitativamente a interface de união compósito/substrato dental por meio de microscopia eletrônica de varredura (MEV). Foram utilizados 60 terceiros molares permanentes, que foram seccionados em um total de 120 fragmentos de esmalte e 120 de dentina, e após o preparo da superfície foram divididos aleatoriamente em grupos 4 grupos (n=30): G1 (controle) - substrato sem irradiação + procedimento restaurador; G2 - procedimento restaurador realizado antes da RT; G3 - procedimento restaurador realizado após a RT; e G4 - procedimento restaurador realizado 6 meses após a RT. Cada um dos grupos foi dividido em 2 subgrupos, sendo empregado no subgrupo \"A\" (SGA) o adesivo AdperTM Single Bond 2 (SB); e no subgrupo \"B\" (SGB) o adesivo Clearfil SE Bond (CL), para o procedimento restaurador. Os espécimes foram irradiados com fração de dose de 2Gy, 5 dias consecutivos, até atingirem a dose total de 60Gy, com um total de 30 frações, durante 6 semanas. O procedimento restaurador foi realizado com resina Z350, e para padronização da restauração foi utilizada uma matriz, de forma que os espécimes apresentam 4mm de altura e 2mm de diâmetro. Os corpos de prova foram submetidos ao teste de resistência ao cisalhamento e depois analisou-se o modo de fratura. Foram selecionados 5 espécimes de cada substrato, para a realização da análise morfológica da superfície dental por meio da microscopia confocal, sendo estes avaliados a cada 10Gy. Para a análise da interface adesiva foram selecionados 3 espécimes de cada grupo e estes foram preparados para realização da MEV. O sistema adesivo CL apresentou desempenho superior, em ambos substratos, quando comparado o SB; quanto ao tempo da restauração, tanto em esmalte quanto em dentina, o grupo 2 apresentou os menores valores; o padrão de fratura predominante para todos os grupos foi a Adesiva; houveram alterações morfológicas notáveis em esmalte e dentina após a dose acumulativa de 30Gy, onde aos 60Gy, no esmalte, os prismas se tornaram amorfos e a camada interprismática degradada, e na dentina os túbulos dentinários encontravam-se completamente obliterados; na análise da interface adesiva do grupo 2 notou-se que quase não houve formação de tags e nos grupos 3 de esmalte a camada adesiva formada era mais fina, porém com formação de tags mais prolongados e na dentina houve formação de gaps. / Head and neck cancer is among all kinds of cancer the seventh most common and radiotherapy (RT) is one of its main treatments, which is widely used and efficient, but side effects are unavoidable. A dental treatment before RT is very important to reduce/eliminate infectious foci in the oral cavity, so it is essential to eliminate carious lesions, and after RT \"radiation caries\", which are a side effect of the treatment, must be eliminated. Adhesive systems are the most indicated to restore teeth of patients undergoing RT, so this study aimed to evaluate in vitro the effect of RT in the moment of the dental restorations in enamel and dentin, using shear bond strength tests, evaluate morphologic alterations at teeth surface during RT, with a laser confocal microscopy and to evaluate qualitatively the union interface of the composite/ dental substrate by scanning electron microscope (SEM). It was used 60 third molars, which were sectioned into 120 fragments of enamel and 120 of dentin, and after the surface prepare the specimens were randomly divided into 4 groups (n=30): G1 (control) - no irradiated substrate + restorative procedure; G2 - restorative procedure performed before RT; G3 - restorative procedure performed after RT; e G4 - restorative procedure performed 6 months after RT. Each group was divided into 2 subgroups: Subgroup \"A\" (SGA) in which was used the AdperTM Single Bond 2 (SB); and subgrup \"B\" in which was used Clearfil SE Bond (CL), for the restorative procedure. The specimens were fractionally irradiated by a dose of 2Gy/day, 5 consecutive days, until it reached a total dose of 60Gy, in a total of 30 fractions, lasting 6 weeks. For the restorative treatment the resin Z350 was chosen, and for standardization it was used a matrix so all specimens had 4mm height and 2mm in diameter. The specimens were submitted to shear bond strength test and the fracture pattern was evaluated. It was chosen 5 specimens of each substrate for the morfological evaluation of the dental surface by a laser confocal microscopy, those were evaluate every 10Gy. To evaluate the adhesive interface it was chosen 3 specimens of each group and those were prepared for the SEM. A better performance was observed for the CL, in both dental substrates, rather than the SB; according to the period of restoration, in both enamel and dentin, Group 2 has showed lower values; the predominant fracture pattern to all groups was the Adesive one; there were morphological alterations in enamel and dentin after a cumulative dose of 30Gy, the prisms of enamel became formless and the interprismatic region was degraded after 60Gy, at the dentin the dental tubules were completely amorphous; the analysis of the interface adhesion has showed that in group 2 tags were barely formed, and in group 3 of enamel the adhesive layer was thinner, but tags were longer, and at the dentin gaps were observed.
290

A importância de alguns adesivos dentais e de vários tratamentos da superfície sobre a dentina humana in vitro. Análise da resistência adesiva por micro-cisalhamento / The relevance of some dental adhesives and different surface instrumentations on human dentin (in vitro). Micro-shear bond strength analyses

Macedo, Manoel Roberto de Paula 05 December 2008 (has links)
O objetivo deste trabalho foi estudar a ação sobre a dentina humana (in vitro) de vários tratamentos de superfície: Lixa, IADR-GM, CVDt e CVDi e de alguns adesivos dentais: Adper Sigle Bond 2 (SB), Clearfil SE Bond (CF) e Adper Prompt L-Pop (PL) avaliando: rugosidade e resistência adesiva por micro-cisalhamento. Foram utilizados 72 terceiros molares hígidos que foram divididos ao meio. As superfícies oclusais das 144 metades dentais foram removidas e padronizadas com Lixa #600. Após receberem os tratamentos de superfície citados, foi avaliada a rugosidade média superficial (Ra) da dentina. Em seguida realizou-se a hibridização e a confecção dos cilindros de resina composta (RC) para finalizar o preparo dos corpos de prova (cps). Após armazenagem de 24h em água destilada a 370C realizou-se o teste de micro-cisalhamento com velocidade de deslocamento de 1mm/min. Os resultados foram submetidos a testes de analise estatística (ANOVA) onde foi comprovado que a menor Ra foi encontrada nas superfícies instrumentadas com Lixa #600 seguida pelo CVDi, IADR-GM que apresentaram rugosidade intermediaria e se igualaram e pelo CVDt que produziram as superfícies mais rugosas. Já para o tratamento de superfície, o CVDi foi que apontou os piores valores de resistência de adesão que com Lixa e IADR-GM. Nos resultados para os adesivos, o PL apresentou valores de resistência à união inferiores ao SB e CF que se igualaram. Já para a interação entre os tratamentos de superfície e os adesivos não houve diferenças estatisticamente significantes entre os grupos tratados com Lixa #600, IADR-GM e CVDt e hibridizados com SB ou CF. Concluiu-se: que a Ra produzida em dentina pelo CVD variou de acordo com o tipo de movimento (CVDt produz maior rugosidade que o CVDi); que não foi possível estabelecer uma correlação entre Ra e valores de resistência adesiva; que o PL apresentou valores de resistência à adesão inferiores aos obtidos pelos adesivos SB e CF; que a interação dos tratamentos Lixa, IADR-GM e CVDt com os três adesivos (SB, CF, PL) mostrou valores mais altos para o SB e CF que se igualaram e menores para o PL; que o fator tratamento não produziu diferença de resistência adesiva para o adesivo CF e o mesmo ocorreu com o PL. / The aim of this in vitro study was to evaluate the micro-shear bond strength and the roughness to human dentin using different instrumentations (SiC #600, diamond rotary bur, CVDt and CVDi) and three dentin adhesive/composite resin systems: Adper Sigle Bond 2 (SB), Clearfil SE Bond (CF) e Adper Prompt L-Pop (PL). Seventy-two third molars were split in the middle. The oclusal third from the one hundred and forty and four halves were removed and standardized using the SiC #600. After the prepared surfaces, which were analyzed the roughness average (Ra) with a surface perfilometer and hybridization. The specimens were then stored in distillated water for 24 hours at 370C. The specimens were then were attached to a micro-shear apparatus and subjected to a micro-shear strength test at a crosshead speed of 1mm/min until failure occurred. The two-way ANOVA indicated that there was significant differences in average roughness between the instrumentations which SiC #600 was the smoothest surface. No differences were detected between dentin surface prepared with diamond bur and CVDi (intermediate in the roughness assessment) and the CVDt gave the roughest surface. The bond strengths varied slightly, though dentin instrumentations with CVDi showed the lowest values than the surfaces prepared with SiC #600 and diamond bur. The bond strengths varied slightly, though adhesives, PL showed lower micro-shear bond strength than SB and CF, which were no significant relevance. The interaction of SiC #600, diamond bur and CVDt using SB and CF showed no significant difference in micro-shear bond strength and higher than PL. The instrumentation showed no significant differences in micro-shear bond strength using CF and PL.

Page generated in 0.0923 seconds