Spelling suggestions: "subject:"bondstrength"" "subject:"bandstrength""
391 |
Cimentos resinosos endodônticos: selamento apical, aspectos micromorfológicos, características físicas e resistência de união à dentina / Resin-based root canal sealers: apical sealing, micromorphological aspects, physical characteristics and bond strength to dentinSouza, Soráia de Fátima Carvalho 12 December 2007 (has links)
Avaliou-se o selamento apical, os aspectos micromorfológicos da interface adesiva, as características físicas e a resistência de união à dentina de cimentos resinosos endodônticos. Setenta e dois pré-molares humanos unirradiculares foram preparados endodonticamente. Trinta e três dentes foram divididos aleatoriamente em 3 grupos, impermeabilizados externamente e obturados pela técnica da condensação lateral acorde as seguintes condições: AH Plus (AH Plus/Gutapercha); AH Primer (Epiphany primer/AH Plus/Gutapercha) e Epiphany (sistema Epiphany). Foram mantidos a 37oC e 100% de umidade por 72 h e, em seguida, imersos em solução aquosa de nitrato de prata a 50% por 24 h. Após secção longitudinal dos dentes, foram realizadas réplicas em resina epóxica. Réplicas e espécimes foram preparados para MEV. Nas réplicas, observou-se a freqüência de fendas apicais na interface dentina/cimento. Nos espécimes, detectou-se e confirmou-se com EDS (Energy Dispersive Spectroscopy) a microinfiltração apical. A interface dentina/cimento foi observada em seis espécimes de cada grupo, selecionados aleatoriamente. A microinfiltração foi similar entre os grupos (p>0,05), sendo influenciada pela freqüência de fendas (p<0,05). Foram observadas tanto regiões com fendas quanto com camada híbrida e longos tags para o grupo Epiphany. Para os grupos AH Primer e AH Plus foi verificada boa adaptação marginal com longos tags vazios e pequenos plugs, respectivamente, embora tenha ocorrido a formação de fendas em ambos. Os outros dentes foram utilizados para as avaliações adicionais: seis, para complementar o estudo micromorfológico da interface adesiva; três, para o ensaio de microdureza Knoop; e, trinta, para o teste de resistência de união. O cimento Epiphany mostrou maior escoamento (p<0,001) e tensão de polimerização (p<0,05), e a menor resistência de união (p<0,001). Os valores de microdureza Knoop decresceram acentuadamente de cervical para apical (p<0,001). Concluiu-se que a total impermeabilização do sistema de canais radiculares não foi obtida com nenhum dos cimentos testados, e que o sistema Epiphany formou mais fendas no ápice. / Resin-based root canal sealers had their apical sealing, micromorphological aspects, physical characteristics and bond strength to dentin evaluated in this study. For this purpose, seventy-two single-rooted human premolars were endodontically treated. Thirty-three teeth were randomly divided into three groups, externally coated with nail varnish and obturated by lateral condensation technique according to such conditions: AH Plus (AH Plus/Gutta-percha); AH Primer (Epiphany primer/AH Plus/ Gutta-percha) and Epiphany (Epiphany system). They were kept in 100% humidity at 37oC for 72 h, and then the specimens were immersed in 50% aqueous silver nitrate tracer solution for 24 h. The teeth were longitudinally sectioned and their epoxy resin replicas were obtained. Both the specimens and their corresponding replicas were prepared for SEM. In the replicas, the frequency of apical gaps at the dentin/cement interface was observed. In the specimens, the apical microleakage was detected and confirmed by EDS (Energy Dispersive Spectroscopy). The dentin/cement interface was observed in six specimens of each group randomly selected. The microleakage was similar among the groups (p>0,05) being influenced by gaps frequency (p<0,05). The Epiphany group presented gap-containing regions, hybrid layer formation and long tags. For AH Primer and AH Plus groups, good marginal adaptation with long empty tags and small plugs, respectively, although gaps formation was found in both groups. The remaining teeth were used for other evaluations: six, to finish micromorphological study at the adhesive interface; three, for Knoop microhardness; and thirty, for bond strength test. The Epiphany resin sealer has showed the highest flow (p<0.001) and polymerization stress (p<0.05), and the lowest bond strength values (p<0.001). The Knoop microhardness values have decreased excessively from the cervical to the apical third (p<0.001). It was concluded that none of the sealers tested achieved a complete sealing of the root canals system, and the Epiphany system has developed more gaps to the apex.
|
392 |
INFLUÊNCIA DA ADAPTAÇÃO DE PINOS DE FIBRA E DE TÉCNICAS RESTAURADORAS ALTERNATIVAS PARA PREENCHIMENTO DE CANAIS RADICULARES EXCESSIVAMENTE ALARGADOS / Influence of fiber posts adaptation and alternative restorative techniques for flared root canal fillingGomes, Giovana Mongruel 20 September 2013 (has links)
Made available in DSpace on 2017-07-24T19:22:29Z (GMT). No. of bitstreams: 1
Giovana Mongruel Gomes.pdf: 3752517 bytes, checksum: 6acad02e468853d81d1d9172fd003844 (MD5)
Previous issue date: 2013-09-20 / The objectives of this study were 1) to evaluate the effect of the influence of the resin cement thickness (RCT) on bond strength (BS) and gap formation (GF) between glass fiber post (FP) and root dentin and 2) to evaluate the BS and fracture
resistance (FR) of restorative techniques for filling oversized root canals. In experiment 1, the roots of 24 mandibular premolars (n=8 per group) were endodontically treated. After one week, the post spaces were prepared depending on
the post adaptation inside the root canal, simulating an ideal adaptation (IdAd),medium adaptation (MeAd) and inadequate adaptation (InAd). All posts were cemented with Excite® DSC and Variolink® II. After a week of cementation, the RCT
and GF were measured with the Image Tool software version 3.0, and the BS by the push-out test. In experiment 2, the roots of 84 mandibular premolars were endodontically treated and, after a week, the conduits were prepared in order to
simulate an oversized root canal, except for the positive control group (PC), which was cemented one prefabricated fiber post (PFP) with the diameter compatible with the conduit. In the other oversized root canals, alternative restorative techniques for filling root canals were tested: NC - negative control (PFP with a smaller diameter than of the root canal), PA - PFP + accessory posts, DAP – direct anatomical post,IAP – indirect anatomical post and RR – root reinforcement with composite resin. All posts were cemented with the same adhesive system and resin cement. After indirect composite crowns cementation, the teeth were submitted to mechanical fatigue (1.2 X 106 cycles, 40 N) before the push-out BS test (n=8) and the FR test (n=6). The data of experiments 1 and 2 were analyzed by ANOVA and paired test (α=0.05). The experiment 1 showed that the smaller RCT resulted in better fiber post adhesion, that
is, higher BS and lower GF. The experiment 2 showed that the use of direct and indirect anatomical posts resulted in the best performance both in BS and FR tests,and must be the first choice for FP cementation in flared roots with oversized root
canals. Therefore, we concluded that the post adaptation to root canal affected significantly its retention. The better the post adaptation, the better the laboratory results. However, in the absence of this ideal condition, the use of direct and indirect
anatomic posts should be the first choice for restoring flared root canals. / Os objetivos deste estudo foram 1) avaliar o efeito da influência da espessura de cimento resinoso (ECR) na resistência de união (RU) e na formação de gaps (FG) entre pino de fibra de vidro (PFV) e dentina radicular e 2) avaliar a RU e resistência
à fratura (RF) de técnicas restauradoras para preenchimento de canais radiculares excessivamente alargados. No experimento 1, as raízes de 24 pré-molares inferiores (n=8 por grupo) foram tratadas endodonticamente. Após uma semana, os condutos
foram preparados em função da adaptação do pino no canal radicular, simulando uma adaptação ideal (AdId), média (AdMe) e inadequada (AdIn). Todos os pinos foram cimentados com Excite® DSC e Variolink® II. Uma semana após a cimentação,
a ECR e a FG foram mensuradas com o software Image Tool versão 3.0 e a RU por meio do teste de push-out. No experimento 2, as raízes de 84 pré-molares inferiores
foram tratadas endodonticamente e, após uma semana, realizou-se o preparo dos condutos, de maneira a simular um canal radicular excessivamente alargado, com exceção do grupo controle positivo (GCP), em que foi cimentado um pino préfabricado (PPF) com calibre compatível ao diâmetro do conduto. Nos outros condutos alargados, técnicas restauradoras alternativas de preenchimento dos canais radiculares foram empregadas: GCN – grupo controle negativo (PPF de diâmetro inferior ao conduto), GPA – PPF + pinos acessórios, GAD – pino anatômico direto, GAI – pino anatômico indireto e GRR – reforço radicular com resina composta
+ PPF. Todos os pinos foram cimentados com o mesmo sistema adesivo e cimento resinoso. Após cimentação de coroas de resina indireta, os dentes foram submetidos à fadiga mecânica (1,2 x 106 ciclos, 40 N) antes de realizar o teste de RU (n=8) e de RF (n=6). Os dados do experimento 1 e 2 foram analisados por ANOVA e teste pareado (α=0,05). O experimento 1 mostrou que quanto menor a ECR melhor a adesão dos PFV, ou seja, maior a RU e menor a FG. O experimento 2 mostrou que
o uso de pinos anatômicos diretos e indiretos mostrou o melhor desempenho nos testes de RU e RF, e deve ser primeira opção para cimentação de PFV em canais radiculares alargados. Portanto, foi evidenciado que a adaptação do pino ao conduto
radicular influenciou significativamente na retenção dos mesmos; quanto mais justa,melhores resultados laboratoriais. Entretanto, na ausência desta condição ideal, o uso de pinos anatômicos diretos e indiretos pode ser a primeira escolha do clínico para tratamento de canais excessivamente alargados.
Palavras-chave: cimentos resinosos, dentina radicular, gap, microscopia eletrônica de varredura, pinos de fibra, raízes enfraquecidas, resistência à fratura, resistência de união.
|
393 |
EFEITO DA APLICAÇÃO SÔNICA DE SISTEMAS ADESIVOS NA ADESÃO DE PINOS DE FIBRA DE VIDRO NO CANAL RADICULAR / EFFECTS OF SONIC APPLICATION OF ADHESIVE SYSTEMS ON BONDING FIBER POSTS TO ROOT CANALSSánchez, Johanna Lizbeth Cuadros 26 February 2014 (has links)
Made available in DSpace on 2017-07-24T19:22:33Z (GMT). No. of bitstreams: 1
Johanna Lizbeth Cuadros Sanchez.pdf: 3888267 bytes, checksum: abbdebf22c3a3a8b49c91f6bc734b34d (MD5)
Previous issue date: 2014-02-26 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Abstract: Luting of posts inside the root canal is still a challenge because of the difficult to bonding mainly in the apical third. The aim of this study was evaluate the
influence of the application of 3 simplified total-etch adhesive systems (Adper Single Bond 2 Ambar, and XP-Bond+self-cure activator) under manual mode or sonic
vibration on the push-out bond strength (POBS), silver nitrate uptake (SNU) and in situ degree of conversion (ISDC) associated to resin cement when used for luted
posts. Methods: The roots of 66 human premolars were prepared and divided into six groups (n=11), according to the following combination: adhesive and application
mode. The posts were cemented in accordance with the manufacturer’s instructions of each cementation system. After water storage, the roots were sectioned
transversely into six slabs and it were tested in POBS (0.5mm/min). Two roots for group were data were immersed in 50% silver nitrate, photo-developed and analyzed
by SEM to measure the SNU. Two roots for group were evaluated by micro-Raman spectroscopy to measure ISDC. The data were analyzed by 3-way repeated measures ANOVA and Tukey's tests (5%). Results: When sonic application was
performed, usually there are a significantly increasing on the POBS (MPa) (35% and 37% respectively) and ISDC (%) (14% and 38% respectively in the medium and apical thirds) and decreasing of SNU (%) for all groups mainly in the medium (64% decreasing) and apical (84%) thirds when compared with manually application
(P < 0.05). / Resumo: A cimentação de pinos dentro do canal radicular ainda é um desafio por causa das dificuldades relativas à adesão, principalmente no terço apical. O objetivo
deste estudo foi avaliar a influência da aplicação de três sistemas adesivos convencionais simplificados (Adper Single Bond 2, Ambar e XP-Bond + self cure ativator) manualmente ou através de um dispositivo sônico vibratório na resistência de união por push-out (RU), na infiltração de nitrato de prata (NI) e no grau de
conversão in situ (GC) associado ao cimento resinoso de cada fabricante, quando utilizado para cimentação de pinos. Métodos: As raízes de 66 pré-molares humanos
foram preparadas e divididas em seis grupos (n = 11), de acordo com a seguinte combinação: adesivo/cimento e modo de aplicação. Os pinos foram cimentados de
acordo com as instruções do fabricante de cada sistema de cimentação apenas variando o modo de aplicação. Depois do armazenamento em água, as raízes foram
seccionadas transversalmente em seis fatias e foram testados em RU (0,5 mm/min). Duas raízes por grupo foram imersas em 50% de nitrato de prata, e após revelação, foram analisadas por MEV para medir a NI. Duas raízes por grupo foram avaliadas por espectroscopia de micro-Raman para medir GC. Os dados foram analisados por análise de variância de 3 fatores de medidas repetidas (terço radicular) e teste de
Tukey (5%). Resultados: Quando a aplicação sônica vibratória foi utilizada, em geral, se observou um aumento significativo na RU (MPa) (35% e 37% respectivamente) e GC (%) (14% e 38% respectivamente nos terços médio e apical) e diminuição da NI (%) para todos os grupos, principalmente nos terços médio (redução de 64%) e apicais (84%) quando comparada com a aplicação manual (p <0,05) e este fenômeno ocorreu para todos os sistemas adesivos/cimentos testados.
|
394 |
Efeito de diferentes tratamentos de superfície na resistência de união de um cimento resinoso à zircôniaScaffa, Polliana Mendes Cándia 13 March 2009 (has links)
As ceramicas a base de zirconia (Y-TZP) apresentam propriedades mecanicas superiores as das demais ceramicas odontologicas. Entretanto, o aumento do conteudo cristalino modificou suas caracteristicas de adesao a cimentos resinosos, tornando necessario o desenvolvimento de metodos mais efetivos de uniao a estes materiais. Este trabalho in vitro pretende, portanto, avaliar a influencia de diferentes tratamentos de superficie e de diferentes agentes de uniao na resistencia ao cisalhamento entre uma zirconia estabilizada por itrio e um agente cimentante autoadesivo (RelyX U100®/3M ESPE). Para tal, cilindros de PROCERA® Allzircon receberam como tratamento de superficie jateamento com oxido de aluminio (Al2O3 - 50 m) ou jateamento com o sistema Rocatec. Sobre a superficie tratada dos cilindros foram aplicados, de acordo com os diferentes grupos experimentais, o sistema adesivo Clearfil SE Bond® (Kuraray Co.), e os primers Metal Zirconia Primer (Ivoclar Vivadent) e Alloy Primer (Kuraray Co.) e, finalmente, o cimento resinoso adotado. Cada especime foi, entao, submetido ao teste de cisalhamento (0,05 mm/min), por meio da acao de uma alca de fio ortodontico passando o mais próximo possivel da interface adesiva. A analise de variancia a um criterios (ANOVA) e o teste de Tukey (p<0,05) mostraram que a realizacao do tratamento de superfície aumentou os valores de resistencia de uniao entre a ceramica e o cimento resinoso. O jateamento com o sistema Rocatec (15,33 MPa) apresentou valores significantemente maiores que o jateamento com Al2O3 (11,93 MPa). A aplicacao dos agentes de uniao resultou em uma maior resistencia adesiva, sendo que o sistema adesivo Clearfill SE Bond (17,07 MPa) teve um comportamento estatisticamente superior aos demais materiais. Entre os primers, o Metal Zirconia Primer (11,26 MPa) apresentou maior valor de resistencia de uniao que o Alloy Primer (10,01 MPa). Portanto, a associacao de um tratamento superficial com um agente de união e valida, ja que promoveu os maiores valores de resistencia adesiva. / Yttrium-stabilized tetragonal zircon polycrystal (Y-TZP) ceramics show better mechanical properties than other dental ceramics. However, the high crystalline content modified their adhesiveness to resin cements, making it extremely necessary to develop a more effective adhesive strategy between them. This in vitro study intends to evaluate the influence of different surface treatments and different bond agents on the shear bond strength between a Y-TZP and self-adhesive resin cement. PROCERA® Allzircon cylinders (3.5 mm in diameter) received a surface airborne abrasion treatment with 50 m aluminum-oxide (Al2O3) particles or with the Rocatec system. According to the experimental groups, the adhesive system Clearfil SE Bond® (Kuraray Co.), and the primers Metal Zirconia Primer (Ivoclar Vivadent) and Alloy Primer (Kuraray Co.) were applied on the treated surface of the cylinders, before the application of the adopted resin cement (RelyX U100®/3M ESPE). Each specimen was submitted to the shear bond strength test (0.5 mm/min), by the action of an orthodontic stainless steel ligature wire (0.5 mm in diameter) loop, wrapped around the resin cement, as close as possible to the adhesive interface. One way-ANOVA and Tukey´s post hoc tests (p<0.05) revealed that surface treatment increased bond strength between the ceramic and the resin cement. Silica coating with the Rocatec system (15.33 MPa) showed significantly higher values than airborne abrasion with Al2O3 (11.93 MPa). Application of all bond agents improved shear bond strength: adhesive system Clearfil SE Bond (17.07 MPa) showed better performance than the other evaluated materials, and Metal Zirconia Primer (11.26 MPa) showed higher bond strength values than Alloy Primer (10.01 MPa). Therefore, the association of a surface treatment with a bond agent is suitable, once it resulted in higher values of adhesive strength.
|
395 |
Análise morfológica e da resistência adesiva dos tecidos dentais duros irradiados com lasers de pulsos ultracurtos / Evaluation of dental hard tissues irradiated with ultra-short pulsed lasers. Influence on surface morphology and microtensile bond strengthSilva, Marina Stella Bello 16 September 2010 (has links)
O desenvolvimento da Odontologia Restauradora culminou com a era das restaurações estéticas adesivas e da intervenção minimamente invasiva, para as quais técnicas inovadoras e materiais de última geração vêm sendo constantemente introduzidos. As técnicas conservadoras visam não somente a remoção do substrato dental cariado, mas também o preparo das paredes da cavidade para a realização da restauração adesiva. Este estudo visou avaliar a possibilidade de introdução dos lasers de pulsos ultracurtos na Odontologia Restauradora, com o intuito de suprir os requisitos básicos para a realização de uma restauração conservadora adequada. A intenção foi de manter os benefícios já conhecidos relacionados à remoção seletiva de cárie com os lasers de alta potência, bem como superar as desvantagens relacionadas às fontes lasers atualmente disponíveis para este fim, como aumento excessivo de temperatura e adesão prejudicada da superfície irradiada à resina composta. Para a melhor avaliação da interação entre os lasers de pulsos ultracurtos e o substrato dental, os experimentos foram realizados em três fases. A Fase 1 visou avaliar o efeito de diferentes comprimentos de onda (355 nm, 532 nm, 1045 nm e 1064 nm), durações de pulso (pico e femtossegundos) e protocolos de irradiação (velocidade de escaneamento da superfície, espessura do espécime, método de refrigeração e taxa de repetição de pulso) em esmalte e dentina. Para a Fase 2, os parâmetros de irradiação que apresentaram resultados mais favoráveis na Fase 1 foram analisados para relacionar o aumento de temperatura com a taxa de ablação e a eficiência de ablação para cada parâmetro. A Fase 3 teve como objetivo analisar a interface adesiva e os valores de microtração da dentina irradiada com os parâmetros selecionados e estudados na Fase 2, utilizando sistemas adesivos do tipo condicione e lave e autocondicionante com diferentes protocolos de adesão (Clearfil SE Bond com e sem Primer, Adper Single Bond com e sem condicionamento ácido). Os resultados obtidos na Fase 1 indicam que a dentina e o esmalte irradiados com lasers de femtossegundos de 1045 nm e picossegundos de 1064 nm apresentam superfície rugosa livre de carbonização. Os protocolos de irradiação selecionados mostram que a irradiação deve ser conduzida com maior velocidade de escaneamento da superfície, e não há necessidade de refrigeração durante a irradiação. Todos os parâmetros utilizados promoveram ablação seletiva do substrato dental, e apresentaram maior taxa de ablação para dentina que para esmalte. A Fase 2 permitiu observar que todos os parâmetros de irradiação selecionados não provocaram aumento de temperatura maior que 6,1 ºC para esmalte e 4,6 ºC para dentina, quando o aumento de temperatura foi aferido no lado oposto ao irradiado, em espécimes de 1 mm de espessura e sem refrigeração. Exceção foi observada para a maior potência do laser de picossegundos, para a qual a temperatura aumentou até 12 ºC em esmalte e 15 ºC em dentina. Os valores obtidos no ensaio de microtração variaram de acordo com os parâmetros de irradiação e o sistema adesivo. A adesão à dentina irradiada com lasers de pulsos ultracurtos apresentou valores de resistência adesiva semelhantes ou significantemente maiores que os obtidos nos grupos controle, para todos os parâmetros de irradiação selecionados. Os resultados obtidos neste estudo indicam que os lasers de pulsos ultracurtos apresentaram resultados favoráveis para o preparo cavitário em esmalte e dentina em relação à morfologia produzida na superfície e ao aumento de temperatura provocado durante a irradiação. A resistência adesiva à dentina irradiada foi semelhante, ou mesmo significantemente maior que a obtida nos grupos controle. Portanto, os lasers de pulsos ultracurtos são considerados uma técnica promissora para a realização de intervenção minimamente invasiva com lasers de alta potência. / The development of restorative dentistry has reached the era of esthetic adhesive restorations and minimally invasive approach, for which innovative techniques and advanced materials are constantly introduced. Conservative techniques aim not only to remove carious dental substrate, but also to prepare cavity surfaces for adhesive restoration. The main objective of this study was to evaluate the possibility of introducing ultra-short pulsed lasers in Restorative Dentistry, in attempt to fulfill the basic requirements of adequate conservative restoration, by maintaining the well-known benefits of lasers for caries removal, but also overcoming disadvantages related to current laser sources available for this purpose, such as temperature increase and damaged adhesion to resin composite. In order to better evaluate the interaction between ultra-short pulsed lasers and dental substrates, experimental procedures were divided in three phases. Phase 1 aimed to evaluate the effect of different wavelengths (355 nm, 532 nm, 1,045 nm, and 1,064 nm), pulse durations (pico and femtoseconds) and irradiation protocols (surface scanning speed, sample thickness, cooling method, pulse repetition rate) on enamel and dentin. For Phase 2, laser parameters with most favorable results in Phase 1 were evaluated to relate temperature increase to ablation rate or ablation efficiency. Phase 3 aimed to analyze adhesive interface and microtensile bond strength to dentin irradiated with the selected parameters by using etch-and-rinse and self-etch adhesive systems with different bonding protocols (Clearfil SE Bond with and without Primer, Adper Single Bond with and without acid etching). The results of Phase 1 indicate that dentin and enamel irradiated with 1,045-nm fs-laser and 1,064-nm ps-laser present a rough surface without carbonization. Irradiation should be conducted with higher scanning speed, and no additional cooling during irradiation was necessary. All parameters provided selective tissue ablation, with higher ablations rate for dentin than enamel. Phase 2 indicated that all parameters tested provoked temperature increase of up to 6.1 ºC for enamel and 4.6 ºC for dentin, when temperature increase was measured at the back side of 1-mm thick samples without cooling during irradiation, except for higher power for ps-laser, for which temperature increased up to 12 ºC for enamel and 15 ºC for dentin. Microtensile bond strength values varied according to laser parameters and adhesive systems used. Adhesion to dentin irradiated with ultra-short pulsed lasers resulted in similar or significantly higher bond strength values than control groups, for all laser parameters analyzed. Based on the results of this study, ultra-short pulsed lasers presented favorable results for cavity preparation in dentin and enamel regarding surface morphology and temperature increase. Adhesion to irradiated dentin was either similar or superior to traditional techniques. Thus, ultra-short pulsed lasers are considered a promising technique for the promotion of laser-supported minimally invasive approach.
|
396 |
Novel RF MEMS Switch and Packaging ConceptsOberhammer, Joachim January 2004 (has links)
Radio-frequency microelectromechanical systems (RF~MEMS) are highly miniaturized devices intended to switch, modulate, filter or tune electrical signals from DC to microwave frequencies. The micromachining techniques used to fabricate these components are based on the standard clean-room manufacturing processes for high-volume integrated semiconductor circuits. RF~MEMS switches are characterized by their high isolation, low insertion loss, large bandwidth and by their unparalleled signal linearity. They are relatively simple to control, are very small and have almost zero power consumption. Despite these benefits, RF~MEMS switches are not yet seen in commercial products because of reliability issues, limits in signal power handling and questions in packaging and integration. Also, the actuation voltages are typically too high for electronics applications and require additional drive circuitry. This thesis presents a novel MEMS switch concept based on an S-shaped film actuator, which consists of a thin and flexible membrane rolling between a top and a bottom electrode. The special design makes it possible to have high RF isolation due to the large contact distance in the off-state, while maintaining low operation voltages due to the zipper-like movement of the electrostatic dual-actuator. The switch comprises two separately fabricated parts which allows simple integration even with RF circuits incompatible with certain MEMS fabrication processes. The two parts are assembled by chip or wafer bonding which results in an encapsulated, ready-to-dice package. The thesis discusses the concept of the switch and reports on the successful fabrication and evaluation of prototype devices. Furthermore, this thesis presents research results in wafer-level packaging of (RF) MEMS devices by full-wafer bonding with an adhesive intermediate layer, which is structured before bonding to create defined cavities for housing MEMS devices. This technique has the advantage of simple, robust and low temperature fabrication, and is highly tolerant to surface non-uniformities and particles in the bonding interface. It allows cavities with a height of up to many tens of micrometers to be created directly in the bonding interface. In contrast to conventional wafer-level packaging methods with individual chip-capping, the encapsulation is done using a single wafer-bonding step. The thesis investigates the process parameters for patterned adhesive wafer bonding with benzocyclobutene, describes the fabrication of glass lid packages based on this technique, and introduces a method to create through-wafer electrical interconnections in glass substrates by a two-step etch technique, involving powder-blasting and chemical etching. Also, it discusses a technique of improving the hermetic properties of adhesive bonded structures by additional passivation layers. Finally, it presents a method to substantially improve the bond strength of patterned adhesive bonding by using the solid/liquid phase combination of a patterned polymer layer with a contact-printed thin adhesive film. / QC 20100617
|
397 |
Strength Properties of Paper produced from Softwood Kraft Pulp : Pulp Mixture, Reinforcement and Sheet StratificationKarlsson, Hanna January 2010 (has links)
For paper producers, an understanding of the development of strength properties in the paper is of uttermost importance. Strong papers are important operators both in the traditional paper industry as well as in new fields of application, such as fibre-based packaging, furniture and light-weight building material. In the work reported in this thesis, three approaches to increasing paper strength were addressed: mixing different pulps, multilayering and reinforcement with man-made fibres. In specific: The effects of mixing Swedish softwood kraft pulp with southern pine or with abaca (Musa Textilis) were investigated. Handsheets of a softwood kraft pulp with the addition of abaca fibres were made in a conventional sheet former. It was seen that the addition of abaca fibres increased the tearing resistance, fracture toughness, folding endurance and air permeance. Tensile strength, tensile stiffness and tensile energy absorption, however, decreased somewhat. Still it was possible to add up to about 60% abaca without any great loss in tensile strength. As an example, with the addition of 30% abaca, the tear index was increased by 36%, while the tensile index was decreased by 8%. To study the effect of stratification, a handsheet former for the production of stratified sheets, the LB Multilayer Handsheet Former was evaluated. The advantage of this sheet former is that it forms a stratified sheet at low consistency giving a good ply bond. It was shown to produce sheets with good formation and the uniformity, evaluated as the variation of paper properties, is retained at a fairly constant level when the number of layers in the stratified sheets is increased. The uniformity of the sheets produced in the LB Multilayer Handsheet Former is generally at the same level as of those produced in conventional sheet formers. The effects of placing southern pine and abaca in separate layers, rather than mixing them homogeneously with softwood pulp were studied. Homogeneous and stratified sheets composed of softwood and southern pine or softwood and abaca were produced in the LB Multilayer Handsheet Former. It was found that by stratifying a sheet, so that a pulp with a high tear index and a pulp with a high tensile index are placed in separate layers, it was possible to increase the tear index by approximately 25%, while the tensile index was decreased by 10-20%. Further, by mixing a pulp with less conformable fibres and no fines with a pulp with more flexible fibres and fines, a synergy in tensile strength (greater strength than that predicted by linear mass fraction additivity) was obtained. The effects of stratifying sheets composed of softwood and abaca were compared to the effects of refining the softwood pulp. Homogeneous and stratified sheets composed of softwood with three different dewatering resistances and abaca were also produced in the LB Multilayer Handsheet Former. It was found that by stratifying the sheets the tear index was retained while the tensile index was increased by the refining. The effects of reinforcing softwood pulp of different dewatering resistances with man-made fibres with low bonding ability were also investigated. Man-made fibres (i.e. regenerated cellulose, polyester and glass fibres) were added in the amounts 1, 3, or 5 wt% to softwood pulp of three different dewatering resistances. It was found that with refining of a softwood pulp and subsequent addition of long fibres with low bonding ability the tensile-tear relationship can be shifted towards higher strength values. The bonding ability of the man-made fibres was evaluated by pull-out tests and the results indicated that, in relation to the fibre strength, regenerated cellulose (lyocell) was most firmly attached to the softwood network while the glass fibres were most loosely attached.
|
398 |
Estudo comparativo da influência de três diferentes métodos de fundição na resistência da interface metal-cerâmica, por meio do teste de cisalhamentoAlonso, Alexandre Abdalla [UNESP] 21 July 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0
Previous issue date: 2006-07-21Bitstream added on 2014-06-13T20:18:41Z : No. of bitstreams: 1
alonso_aa_me_sjc.pdf: 816482 bytes, checksum: 5e7f9255e591189fa6c1f9a1470015f7 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este trabalho avaliou a influência de três diferentes métodos de fundição (maçarico e centrífuga elétrica - G1, indução eletromagnética - G2 e plasma - G3), sobre a interface de uma liga metálica de Pd-Ag-Sn e uma cerâmica odontológica de cobertura. Foram encerados para cada método de fundição 30 padrões em cera. Os padrões em cera foram incluídos e fundidos de acordo com as especificações de cada fabricante de equipamentos de fundição. Após o processo de sinterização da cerâmica, os corpos de prova (CP) foram divididos em dois subgrupos. Um subgrupo foi submetido diretamente ao ensaio mecânico de cisalhamento, e o outro recebeu ciclagem térmica e mecânica, seguido do ensaio mecânico de cisalhamento. Então, para cada método de fundição (n=24), metade dos CP receberam ciclagem térmica e mecânica (n=12), e a outra metade os CP não foram ciclados. Após o cisalhamento, os CP foram examinados em estereomicroscópio, para verificação do padrão de fratura. Os valores coletados durante o ensaio de cisalhamento receberam análise estatística, (ANOVA e teste de Tukey), com nível de significância de 5%. Os resultados mostraram os seguintes valores (média l desvio padrão), para os subgrupos sem ciclagem: 108,35 l 22,97 MPa para o maçarico; 103,64 l 28,28 MPa para a indução; 93,79 l 11,07 MPa para o plasma; para o sub grupo com ciclagens: 97,96 l 18,30 MPa para o maçarico; 62,34 l 11,26 MPa para a indução; e 58,10 l 10,66 MPa para o plasma. Conclui-se que os grupos Plasma com ciclagem e Indução com ciclagem apresentam médias dos resultados semelhantes e menores que os demais. / The aim of this study was to evaluate the three differents methods of melting (gas oxygen torch and eletrical centrifuge G1, Induction electrical centrifuge G2 e automated casting machine with gas argon - G3), between the interface of the Pd-Ag-Sn alloy, and a dental ceramic. Thirty standardized specimens were waxed for each method of melting. The specimens were included and melted in agreement with each manufacturer's melting equipments specifications. Following a feldspatic ceramic was applied over the metal copping, according to the manufacturers' instructions The specimens were divided in two subgroups. One subgroup was directly submitted to the shear bond strength test; and the other subgroup was thermo-cycled, mechanic-cycled, followed by the shear bond strength test. The fractured specimens were evaluated under a stereoscopic loup (20 X magnification), and the type of fracture recorded. The data collected during the shear bond strength test were submitted to ANOVA and Tukey's test statistical analysis with 5% level of significantly. The results showed the following values (mean l S.D.), for the sub groups without cycling: 108,35 l 22,97 MPa by gas oxygen torch and eletrical centrifuge, 103,64 l 28,28 MPa by Induction electrical centrifuge, 93,79 l 11,07 MPa by automated casting machine with gas argon and for the sub group with cycling 97,96 l 18,30 MPa by gas oxygen torch and electrical centrifuge, 62,34 l 11,26 MPa by Induction electrical centrifuge, and 58,10 l 10,66 MPa by automated casting machine with gas argon. Considering this study we can conclude that the automated casting machine with gas argon with cycling and Induction electrical centrifuge with cycling presents similar averages and lower than the others groups.
|
399 |
Análise das propriedades estruturais, morfológicas e mecânicas de duas marcas comerciais diferentes de dissilicato de lítio para o sistema CAD/CAMTavares, Lucas do Nascimento 14 February 2017 (has links)
O objetivo deste presente estudo foi comparar duas marcas comerciais diferentes de Dissilicato de Lítio para o sistema CAD / CAM (IPS e.max CAD e Rosetta SM CAD / CAM), avaliando suas propriedades estruturais, morfológicas e mecânicas. Para avaliar as propriedades estruturais foram necessárias duas amostras de cada grupo, para serem analisadas por meio do DRX (difração de raios X). As propriedades morfológicas foram analisadas utilizando o MEV (Microscopia eletrônica de Varredura) antes e depois do tratamento térmico, e o teste de porosidade, realizado através de uma tomografia computadorizada em 3D (micro-CT). Para avaliar as propriedades mecânicas foi realizado o teste flexural de três pontos e o teste de microcisalhamento, e para isto foram selecionados dez espécimes de cada grupo para cada teste. Os valores médios de porosidade e da resistência flexural de três pontos foram analisados pelo teste t e a resistência de união obtida através do microcisalhamento foi analisada pelo teste Anova Two-way. Todos os testes usaram um nível de significância de α = 0,05.
Os resultados obtidos pela análise estrutural realizada pelo DRX apresentaram picos no difractograma correspondentes ao Metassilicato de Lítio e o Dissilicato de Lítio, com intensidades semelhantes para ambos os grupos testados. Após realizar a microscopia eletrônica de varredura, não foi encontrado diferenças na morfologia dos cristais, em ambas as cerâmicas testadas, antes e depois do tratamento térmico. O teste de porosidade não mostrou diferença estatisticamente significativa entre o valor total de poros encontrados. Ambos os resultados dos testes mecânicos não apresentaram diferenças estatísticas significativas entre os grupos avaliados.
Baseado nos resultados encontrados, não houve diferença entre as duas marcas comerciais testadas, em relação as suas propriedades estruturais, morfológicas e mecânicas. / The aim of the present study was to compare two different brands of lithium disilicate CAD/CAM blocks (IPS e.max CAD and Rosetta SM CAD/CAM), evaluated by structural, morphological and mechanical properties.
Two specimens of each group were analyzed using x-ray diffraction (XRD) to evaluate the structures of the ceramic material. Morphologic properties were analyzed using the Scanning Electron Microscopy (SEM) before and after the heat treatment; and porosity test was performed using a 3D micro-computed tomography analyses (micro-CT). Ten specimens of each group were submitted to three-point flexure strength and microshear bond strength tests, to analyze the mechanical properties of both brands. Mean values of porosity test and three-axial flexural strength were analyzed by t Test, and the microshear bond strength was analyzed by Anova two-way. All tests used a significance level of α=0.05.
The structure results performed by XDR, presented high peak positions corresponding to the standard lithium metasilicate and lithium disilicate, with similar intensities for both tested groups. The morphologic results demonstrated similar patterns of crystalline structure, before and after the heat treatment and the porosity test showed no difference between the number and size of the pores found. Both mechanical tests results did not present statistically significant differences between the samples.
Based on the results, there was no difference in relation to their structural, morphological and mechanical properties, between the two commercial brands tested. / Dissertação (Mestrado)
|
400 |
Influência da conicidade do pilar e tipo de agente cimentante na retentividade de coroas metálicas cimentadas sobre pilares personalizáveis de implantesDantas, Talita Souza 16 December 2011 (has links)
Several factors must be considered in the selection of angled abutments. In these situations, the clinician should find a practical way to overcome the lack of retention. The purpose of this study was to evaluate the bond strength of metallic crowns cemented to straight and angled customizable abutments with different definitive luting agents. Ninety one regular external hex analogs and abutments were divided in Control group (C): customizable straight abutment cemented with zinc phosphate (n = 10); three groups (n = 10) with 17° angled abutment cemented with zinc phosphate (A17ZP), Panavia F (A17RM) and RelyX U100 (A17R) cements and more three groups (n = 10) with 30° angled abutment also cemented with zinc phosphate (A30ZP), Panavia F (A30RM) and RelyX U100 (A30R) cements. The metal copings were cemented onto their corresponding metal dies and crowns cemented with Panavia F were pre-treated with an alloy primer containing an acid-phosphated monomer (MDP). Data from the all groups were compared to control group with a 1-way ANOVA (α=.05) and Dunnet s test, and comparison between tested groups were done with 2-way ANOVA (α=.05) and Tukey s test. SEM and CLSM evaluation were performed (n = 3) aiming to investigate microscopic features of the abutment-cement-crown interfaces. The mean force (SD) required to dislodge the crowns in the C, A17ZP, A17RM, A17R, A30ZP, A30RM and A30R groups was 357,26 (62,21) N; 251,50 (20,13) N; 397,05 (88,48) N; 328,71 (79,87) N; 276,70 (17,96) N; 377,81 (90,61) N and 335,42 (88,34) N respectively. Panavia F presented the higher tensile bond strength results and zinc phosphate the lower between the tested groups. Only A17ZP group was different from control group (p=.007) and the abutment taper has no influence in retentive values. Zinc phosphate showed an inhomogeneous cement line in SEM and CLSM analysis. The presence of MDP primer could be perceived in CLSM images of Panavia F group. Within the limitations of this in vitro study, the Panavia F presented the higher bonding strength between tested groups, however, all 3 cements tested were similar to control group except A17ZP group, showing that in the conditions of the study they all can be successfully used. / Vários fatores devem ser considerados na seleção dos pilares angulados, assim, muitas vezes, o clínico deve encontrar uma forma prática de superar a falta de retenção resultante das características desse tipo de pilar. O objetivo deste estudo foi avaliar a resistência de união de coroas metálicas cimentadas sobre pilares personalizáveis retos e angulados, cimentados com diferentes agentes de cimentação definitivos. Noventa e um análogos de implantes regulares do tipo hexágono externo foram divididos em Grupo controle (C): pilar reto personalizável cimentado com fosfato de zinco (n = 10); três grupos (n = 10) com pilares angulados de 17° cimentados com fosfato de zinco (A17F), Panavia F (A17RM) e RelyX U100(A17R) e ainda mais três grupos (n = 10) com pilares angulados de 30° também cimentados com cimento de fosfato de zinco (A30F), Panavia F (A30RM) e RelyX U100 (A30R). Coroas de Níquel-Cromo foram confeccionadas e cimentadas em seus pilares correspondentes sendo que as coroas cimentadas com Panavia F foram pré-tratadas com um primer para metal contendo monômero ácido fosfatado (MDP). Dados de todos os grupos foram comparados ao grupo controle por meio da análise de variância ANOVA - One way (α =0,05) e teste de Dunnet, e a comparação entre os grupos testados foi realizada por meio de análise de variância ANOVA Two way (α =0,05) e teste de Tukey. Ainda as avaliações em MEV e MVCL foram realizadas com 3 amostras representativas de cada grupo com o objetivo de investigar as características microscópicas das interfaces pilar-coroa-cimento. A média de força (DP) necessária para deslocar as coroas nos grupos C, A17F, A17RM, A17R, A30F, A30RM e grupos A30R foram, respectivamente, 357,26 (62,21) N; 251,50 (20,13) N; 397, 05 (88,48) N; 328,71 (79,87) N; 276,70 (17,96) N; 377,81 (90,61) N e 335,42 (88,34) N. O cimento Panavia F apresentou os resultados mais elevados de resistência a tração (RT) e o fosfato de zinco apresentou os menores valores de RT entre os grupos testados. Apenas o grupo A17F foi estatisticamente diferente do grupo controle (p = 0,007) e a inclinação das paredes axiais do pilar não influenciou os valores de retenção obtidos. O fosfato de zinco apresentou uma linha de cimentação não homogênea na análise em MEV e MVCL. A presença de primer contendo MDP pode ser percebida nas imagens de MVCL do grupo Panavia F. Dentro das limitações deste estudo in vitro, o Panavia F apresentou a maior resistência de união entre os grupos testados, no entanto, todos os três cimentos testados foram semelhantes ao grupo controle, exceto o grupo A17F grupo, mostrando que nas condições do estudo todos eles podem ser usados com sucesso. / Mestre em Odontologia
|
Page generated in 0.0823 seconds