• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 26
  • 12
  • 6
  • 4
  • 3
  • 1
  • 1
  • Tagged with
  • 69
  • 48
  • 21
  • 12
  • 12
  • 11
  • 9
  • 7
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Why merger talks collapse: an exploratory study about contributing factors to ‘wedding cold feet' and deal making failure in mergers and acquisitions from the perspective of active deal making professionals in Brazil

Sales, Augusto Cesar Silva 10 October 2014 (has links)
Submitted by Augusto Sales (asales@me.com) on 2014-12-17T17:13:02Z No. of bitstreams: 1 THESIS - Why merger talks collapse ASales - FINAL SUBMITTED w FICHA etc 20141217.pdf: 646710 bytes, checksum: 69261948b9d356282a8c8d684889e7e1 (MD5) / Approved for entry into archive by Janete de Oliveira Feitosa (janete.feitosa@fgv.br) on 2014-12-19T15:37:30Z (GMT) No. of bitstreams: 1 THESIS - Why merger talks collapse ASales - FINAL SUBMITTED w FICHA etc 20141217.pdf: 646710 bytes, checksum: 69261948b9d356282a8c8d684889e7e1 (MD5) / Approved for entry into archive by Marcia Bacha (marcia.bacha@fgv.br) on 2015-02-05T12:34:43Z (GMT) No. of bitstreams: 1 THESIS - Why merger talks collapse ASales - FINAL SUBMITTED w FICHA etc 20141217.pdf: 646710 bytes, checksum: 69261948b9d356282a8c8d684889e7e1 (MD5) / Made available in DSpace on 2015-02-05T12:37:06Z (GMT). No. of bitstreams: 1 THESIS - Why merger talks collapse ASales - FINAL SUBMITTED w FICHA etc 20141217.pdf: 646710 bytes, checksum: 69261948b9d356282a8c8d684889e7e1 (MD5) Previous issue date: 2014-10-10 / Why merger talks collapse: an exploratory study about contributing factors behind ‘wedding cold feet' and deal making failure in Mergers and Acquisitions from the perspective of active deal making professionals in Brazil. One basic question encouraged this study: after all the effort, expectations and money usually invested in dealmaking, why are so many transactions simply abandoned, even when the benefits are clear for the business, shareholders, customers and employees?
62

Influence of copper contamination on thermophysical, radiation, and dielectric breakdown properties of CO2-N2 mixtures as replacement of SF6 in circuit breakers / Influence des vapeurs de cuivre sur les propriétés thermo-physiques, radiatives, et diélectriques des mélanges CO2-N2 destinés à remplacer le SF6 dans les disjoncteurs haute-tension

Zhong, Linlin 16 June 2017 (has links)
La thèse porte sur les propriétés thermodynamiques, de transport, de diffusion de rayonnement, et diélectriques des mélanges CO2-N2 contaminés par du cuivre, pour des températures de 300 - 30,000 K et des pressions 0.1 - 16 bar. Les motivations de ce travail ainsi qu'un état de l'art sur le remplacement du SF6 et l'influence des vapeurs métalliques dans de tels dispositifs sont présentés dans le chapitre 1. Le chapitre 2 étudie les compositions à l'équilibre calculées à partir de la méthode de minimisation de l'énergie libre de Gibbs, en considérant la présence de phases condensées dans le plasma. A partir de ces compositions, nous présentons les propriétés thermodynamiques comme la densité de masse, l'enthalpie et la chaleur spécifiques à pressions constante. Les corrections de Virial et Debye-Hückel sont prises en compte pour tenir compte de l'effet des ions et des hautes pressions. Dans le chapitre 3, les coefficients de transport (conductivité électrique, viscosité, et conductivité thermique) et les coefficients de diffusion combinés (coefficients de diffusion ordinaires combinés, ceux liés au champ électrique, aux gradients de pression et de température) sont calculés selon la théorie de Chapman-Enskog. Les intégrales de collision nécessaires au calcul de ces coefficients sont obtenues pour les interactions neutre-neutre et neutre-ion à partir d'un potentiel de Lennard-Jones modifié. Dans le chapitre 4, les coefficients d'émission nette (CEN) sont calculés en considérant le rayonnement des raies atomiques, du continuum atomique, des raies moléculaires et du continuum moléculaire. Les élargissements en pression des raies (élargissements de Van der Waals et de résonance), les élargissements Stark, et l'élargissement sont pris en compte dans la détermination d'un facteur de fuite qui permet de simplifier le calcul du coefficient d'émission des raies. Le rayonnement du continuum atomique tient compte de l'attachement radiatif, de la recombinaison radiative et du Bremsstrahlung. Dans le chapitre 5, les propriétés diélectriques de claquage (incluant la fonction de distribution d'énergie des EEDF), le coefficient réduit d'ionisation réduit, le coefficient réduit d'attachement électronique, le coefficient effectif réduit d'ionisation, et le champ critique réduit) du gaz chaud ont été calculés sur la base de l'approximation à deux termes de l'équation de Boltzmann. Les interactions, incluant les collisions élastiques, excitation, ionisation et attachement entre électrons et espèces neutres sont pris en compte dans la résolution de l'équation de Boltzmann. Les sections efficaces d'ionisation de Cu2 et CuO non disponibles dans la littérature ont été calcules selon la méthode DM. La conclusion des travaux et leurs perspectives sont présentés dans le chapitre. / Sulfur hexafluoride (SF6) is a greenhouse gas designated by the Kyoto Protocol because of its extremely high global warming potential (GWP). CO2, N2, and their mixtures have the potential to replace SF6 in certain applications, such as circuit breakers. In these electric apparatus, copper vapour resulting from the heating of electrodes can modify the characteristics of arc plasmas, which must be taken into account when setting up physical models. This dissertation, therefore, investigates the thermodynamic, transport, diffusion, radiation, and dielectric breakdown properties of CO2-N2 mixtures contaminated by copper at temperatures of 300 - 30,000 K and pressures of 0.1 - 16 bar. The equilibrium compositions are calculated using the minimization of Gibbs free energy with consideration of condensed species. Copper vapour is found to condense at temperatures below 3000 K. Based on the compositions, the thermodynamic properties, including mass density, specific enthalpy, and specific heat at constant enthalpy, are determined according to their definitions. The Debye-Hückel corrections are also considered in the calculation of compositions and thermodynamic properties. The transport coefficients (including electrical conductivity, viscosity, thermal conductivity) and combined diffusion coefficients (including the combined ordinary diffusion coefficient, combined electric field diffusion coefficient, combined temperature diffusion coefficient and combined pressure diffusion coefficient) are calculated based on the Chapman-Enskog theory. The newly developed Lennard-Jones like phenomenological model potential is adopted to describe the neutral-neutral and neutral-ion interactions in determining collision integrals. The net emission coefficients (NEC) of gas mixtures are calculated with considering atomic lines and continuum and molecular bands and continuum. The pressure broadening (Van der Waals broadening and the resonance broadening), Stark broadening, and Doppler broadening are taken into account in the determination of escape factors. The continuum radiation of atoms is described by radiative attachment, radiative recombination, and Bremsstrahlung. The dielectric breakdown properties (including EEDF, reduced ionization coefficient, reduced electron attachment coefficient, reduced effective ionization coefficient, and reduced critical electric field strength) of hot gas mixtures are calculated based on the two-term approximation of the Boltzmann equation. The interactions, including elastic, excitation, ionization and attachment collisions, between electrons and neutral species are taken into account in solving the Boltzmann equation. The ionization cross sections of Cu2 and CuO which are unavailable in literatures are calculated using the DM method. Compared with SF6-Cu mixtures, CO2-N2-Cu mixtures present much different thermophysical, radiation, and dielectric breakdown properties. As an arc quenching gas, CO2-N2-Cu mixtures have lower ??Cp and thermal conductivity at low temperatures but present higher ??Cp, thermal conductivity, and NEC in the medium temperature range. As an insulating medium, the hot CO2-N2-Cu mixtures have much poorer dielectric strength below 2000 K, whereas above 2000 K, they present better dielectric breakdown performance than SF6-Cu mixtures.
63

Proposta de nova topologia com número reduzido de chaves para inversor de sete-níveis alimentado por duas fontes de tensão contínua assimétricas não isoladas / Proposal of a novel topology with reduced number of switches for a seven-level inverter supplied by two non isolated assimetric DC voltage sources

Meier, Martin Breus 29 September 2017 (has links)
Os inversores multiníveis podem se beneficiar de filtros de saída reduzidos devido ao menor conteúdo harmônico do sinal sintetizado, dado que suas saídas possuem menores diferenças de tensão durante seu chaveamento. Sua desvantagem é causada pelo elevado número de chaves controladas normalmente necessário para seu funcionamento, e seus circuitos auxiliares. No objetivo de reduzir o número de chaves utilizadas em um inversor de sete níveis, uma nova topologia para um inversor de sete níveis de tensão é apresentada, construída a partir de duas fontes de tensão assimétricas conectadas em série e seis chaves semicondutoras. Este trabalho analisa os princípios de operação desta topologia e a lógica de chaveamento necessária para seu funcionamento. O arranjo proposto não oferece a possibilidade de redução de tensão sobre as chaves, conforme apresentado nas topologias clássicas de inversores com ponto neutro grampeado a diodo ou capacitor e de células em série, mas reduz a quantidade dos componentes necessários para a composição dos sete níveis, sendo possível utilizá-lo em inversores de baixa tensão, devido à seu menor tamanho e complexidade. O estudo apresenta a estrutura resultante em forma de um inversor monofásico por modulação de largura de pulso com disposição das portadoras em oposição de fase, com sete níveis igualmente espaçados, utilizando apenas seis chaves e duas fontes de tensão com alimentação assimétrica, em que a principal fonte tem o dobro da tensão da outra fonte. O funcionamento da topologia é verificado em simulação e implementação de protótipo de 860W. Uma outra versão também é apresentada analiticamente, com melhor grampeamento da tensão, utilizando oito chaves comandadas com uma lógica mais simplificada. Por fim, algumas propostas são sugeridas para a geração dos dois barramentos de tensão necessários. / Multilevel inverters can benefit from reduced output filters due to the lower harmonic content of the synthesized signal, since their outputs have lower voltage differences during their switching. Its disadvantage is caused by the high number of controlled switches and its auxiliary circuits normally required for its operation. In order to reduce the number of switches used in a seven-level inverter, a new topology for a seven level and its auxiliary circuits inverter is presented, constructed from two asymmetrical voltage sources connected in series and six semiconductor switches. This work analyzes the principles of operation of this topology and the switching logic required for its operation. The proposed arrangement does not offer the possibility of voltage reduction on the switches, as presented in the classical inverters topologies with diode or capacitor clamping or the series connected cells, but it reduces the amount of components necessary for the composition of the seven levels, being possible to use it in low voltages inverters, due to its smaller size and complexity. The study presents the resulting structure in the form of a single-phase inverter, using the pulse-width modulation with phase-contrast carriers technique, with seven equally spaced levels, using only six switches and two voltage sources with asymmetrical voltages, in which the main source has double the voltage of the other. The operation of the topology is checked with simulation and an implementation of a 860W prototype. Another version is also presented analytically, with better voltage clamping, using eight keys controlled with a more simplified logic. Finally, some proposals are suggested for the generation of the two necessary voltage rails.
64

Musical and Dramatic Functions of Loops and Loop Breakers in Philip Glass's Opera The Voyage

Wu, Chia-Ying (Charles) 05 1900 (has links)
Philip Glass's minimalist opera The Voyage commemorates the 500th Anniversary of Christopher Columbus's discovery of America. In the opera, Philip Glass, like other composers, expresses singers' and non-singers' words and activities by means of melodies, rhythms, chords, textures, timbres, and dynamics. In addition to these traditional musical expressions, successions of reiterating materials (RMs, two or more iterations of materials) and non reiterating materials (NRMs) become new musical expressions. However, dividing materials into theses two categories only distinguishes NRMs from RMs without exploring relations among them in successions. For instance, a listener cannot perceive the functional relations between a partial iteration of the RM and the NRM following the partial RM because both the partial RM and the NRM are NRMs. As a result, a listener hears a succession of NRM followed by another NRM. When an analyst relabels the partial RM as partial loop, and the NRM following the partial RM as loop breaker, a listener hears the NRM as a loop breaker causing a partial loop. The musical functions of loops and loop breakers concern a listener's expectations of the creation, sustaining, departure, and return to the norm in successions of loops and loop breakers. When a listener associates the satisfaction and dissatisfaction of these expectations with dramatic devices such as incidents, words in dialogues and soliloquies, and activities by singers and non-singers, loops and loop breakers in successions become dramatically functional. This dissertation explores the relations among musical and dramatic functions of loops and loop breakers in Glass's musical commemoration of Columbus.
65

Návrh prezentačního rozváděče nn / Design of presentation electric switchboard for LV

Hlaváč, Jan January 2018 (has links)
This master’s thesis deals with the design of electric switchgear for low voltage, which will serve for presentation purposes. The switchgear is analogy of the modular system MNS 3.0, which includes the latest equipment of ABB Ltd. that is currently available on the market. Switchgears of this type are widely used in industry primarily for controlling motor units. For this reason, in the switchgear there are located motor starters in various performances, as well as distribution modules. In addition, the switchgear has an automatic transfer switch function in case of failure of one of the power supplies. The complete documentation of the switchgear is processed in the professional software EPLAN Electric P8 with use of the 3D software EPLAN Pro Panel for modelling device compartments. The final part of the thesis is the calculation of the maximum cable lengths that a potential customer can connect to the switchgear. In addition, an analysis of the power and control circuits was carried out for voltage drop calculations, as well as the effect of these voltage drops and capacitance of long control cables on the actuation of contactors.
66

Simulace nadproudové spouště jističe / Simulation of circuit-breaker trip unit

Dostál, Lukáš January 2010 (has links)
Securing of electrical devices is important not only to protect against destruction under the effects of electric current, but also for protection of people or animals against electric shock. With increasing of living standards goes hand in hand increasing of the electricity consumption. Therefore In the grid of low voltage, there are increasing short-circuit currents. With improving technology is posed considerable demand on the performance, security and switching capacity of circuit breakers. This thesis is oriented on development of thermal and electromagnetic switch of circuit breaker on which is put a big demand in development of new types of circuit breakers. The thesis is interesting because of comprehensive use of circuits’ breakers since it can be used in AC and DC networks with frequency of 50 Hz and 400 Hz.
67

Modelling, simulation and optimisation of a crushing plant

Ndhlala, Blessing 07 1900 (has links)
African copper PLC’s flagship is the copper producing Mowana mine located 129 km from Francistown in the North-Eastern part of the Republic of Botswana. The processing operation at Mowana is a standard flotation plant designed to produce copper concentrates from oxide, supergene, and sulphide ores. The expected average output of 16.2 tons per hour of copper concentrates has never been attained since plant commissioning. The major bottleneck has been established to be located around the crushing circuit of the Mowana production chain. The major hypotheses of this research are that performance in a crushing plant is adversely influenced by moderate and discrete changes in the process. The ultimate objective is to develop a dynamic process simulator, administered in Simulink/MATLAB® background, for application in the design of a control model utilising two crusher variables and a self-tuning control algorithm. In this research work, a process model describing the dynamic operation of an Osborn 57S gyrasphere cone crusher is investigated. Modelling of the Mowana crushing circuit is carried out by combining the steady-state and dynamic components of the crushing equipment in the Simulink/Matlab® environment. Eccentric speed (ES) and closed-side setting (CSS) are amongst the important inputs to the models. The rest of the inputs (crusher power, crusher cavity level, federate, pulley diameters, liner wear measurement, number of teeth of the pinion and bevel gear) are extracted from the data collected across the Mowana mine crushing circuit. While it has been demonstrated that the crusher CSS is the most influential controllable parameter, it has also been demonstrated that crusher capacity and power can be used effectively to optimise the circuit. The use of crushing power and cavity level control is suitable for the crushing circuit since the crushers are running on a constant ES and the CSS is set and reset manually. The outcome of the study presents an insight into the optimization of the Mowana mine crushing circuit through the design of a self-tuning controller for the cone crusher and for prototyping, parameters of a PID controller were determined in the Simulink/MATLAB® environment. The simulation involved the optimisation of the control model as a function of the cavity level of and the power drawn by the cone crusher. A self-tuning control algorithm at PLC and SCADA level of control was then tested. This formed the simulations and training platform. The outcome of the simulations carried out in this research needs to be validated against the real Mowana crushing process control upgrade. This will then inform the modifications and recommended crusher motor resizing exercise to be implemented. / Electrical and Mining Engineering / M. Tech. (Engineering: Electrical)
68

Klasická i neklasická řešení venkovních rozvoden 123 kV / Conventional and Unconventional Solving of 123 kV Outdoor Switchgears

Petrucha, Lukáš January 2008 (has links)
This graduation theses shows some of possible versions of outdoor switchgears with very high voltage, especially on the level 123 kV both concerning own complement of classic outdoor switchgears with devices as are overvoltages limiter, disconnecting switchgears, circuit breakers, etc., and compact connections. In the introduction of my theses there are explained basic ideas and theories of switchgears and described main devices and equipments which create classic (from equipment setting point of view) outdoor switchgears of very high voltage. Subsequently it describes possible ways of linking-up of these devices in the complex of switchgears themselves according to possible dispositions arranged and busbars systems. The same focus is dedicated to new, non-classic (non-standard solution in terms of devices solution), compact solving of outdoor very high voltage modules either by air isolated or by means of enclosed technology with gas SF6 which represent innovative solving first of all from reduction of built up area point of view which is very important from economic point of view especially during constructions of new switchgears. In the end of my theses there are mentioned also brief evaluations of producers and economics for development and operation of individual technologies. I used for my work materials of companies CEZ, a. s., Siemens, a. s. and Abb, a.s.
69

Beitrag zur thermischen Dimensionierung von Niederspannungs-Schaltgerätekombinationen

Adam, Robert 03 December 2019 (has links)
In der Niederspannungstechnik werden die Anlagen zum Übertragen und Verteilen von Elektroenergie als Niederspannungs-Schaltgerätekombinationen bezeichnet. Die Anlagen sollen ihre Aufgaben möglichst wartungsfrei über einen Zeitraum von mehreren Jahrzehnten erfüllen. Damit ein langzeitstabiler Betrieb der Niederspannungs-Schaltgerätekombinationen möglich ist, müssen die Anlagen mindestens normgerecht thermisch dimensioniert sein. Um die Erwärmung von Niederspannungs-Schaltgerätekombinationen zuverlässig und effizient zu berechnen, wird in dieser Arbeit die Wärmenetzmethode genutzt. In der Wärmenetzmethode werden die Vorgänge der Erwärmung mit Hilfe von Wärmestromquellen, Temperaturquellen, Wärmewiderständen und Wärmekapazitäten nachgebildet. Einen wesentlichen Einfluss auf die Erwärmung einer Schaltgerätekombination haben die in den Wärmequellen der Anlage erzeugten Verlustleistungen. Die dominanten Wärmequellen (Hauptwärmequellen) innerhalb von Niederspannungs-Schaltgerätekombinationen werden in dieser Arbeit untersucht und die Ergebnisse in die Wärmenetzmethode integriert. Mit den Ergebnissen werdenmit Hilfe der Wärmenetzmethode die Erwärmungen verschiedener Betriebsmittel einer Niederspannungs-Schaltgerätekombination berechnet und anhand von Experimenten verifiziert. Die Wärmenetze der einzelnen Betriebsmittel werden zum Gesamt-Wärmenetz einer Niederspannungs-Schaltgerätekombination zusammengeschaltet. Die mit diesem Wärmenetz berechneten Temperaturen werden dann durch Experimente an der Versuchsanlage einer Niederspannungs-Schaltgerätekombination verifiziert. Eine der Hauptwärmequellen in Niederspannungs-Schaltgerätekombinationen sind die ohmschen Leitungsverluste in den Strombahnen der Hauptsammel- und Feldverteilerschienen. Bei Drehstrombelastung werden die hier in den einzelnen Teilleitern erzeugten Verlustleistungen durch die Stromverdrängung aufgrund des Skin- und den überlagerten Proximity-Effekts maßgeblich beeinflusst. Gegenüber einer Gleichstrombelastung unterscheiden sich die Verlustleistungen jedes einzelnen Teilleiters um den Leistungsfaktor k3~. Für Drehstromschienensysteme mit mehreren Teilleitern existieren bisher nur unzureichende Angaben zum Leistungsfaktor k3~ durch den Skin- und den Proximity-Effekt. In dieser Arbeit wurden FEM-Modelle aufgebaut, die Leistungsfaktoren k3~ für unterschiedliche Schienenanordnungen berechnet und anhand experimenteller Untersuchungen verifiziert. Weitere Hauptwärmequellen in Niederspannungs-Schaltgerätekombinationen sind die in den Anlagen eingebauten Betriebsmittel zum Schalten, Trennen und Schützen (z. B. Leistungsschalter, Trennschalter, Trenneinrichtungen, Sicherungen). Neben den Schaltkontakten selbst gehören die thermischen Schutzauslöser und Sicherungen zu den Hauptwärmequellen in den Strombahnen der Schaltgeräte. Um die Erwärmung der Geräte genau zu berechnen, müssen der Aufbau der Strombahnen und die Verteilung der Widerstände bekannt sein. Diese Widerstände können im Allgemeinen nur gemessen werden. Dabei hat sich zum einen gezeigt, dass die gemessenen Widerstände der Schaltkontakte von Kompaktleistungsschaltern auch im selben Gerät stark variieren können. Zum anderen sind die Widerstände der Schaltkontakte so dominant, dass in ihnen bis zu 47 % der gesamten Verlustleistungen eines Kompaktleistungsschalters entstehen können. Bedingt durch die zunehmende kompakte Bauweise der Anlagen erzeugen die Drehstromfelder der Sammelschienen hohe magnetische Feldstärken in umgebenden Metallteilen. In den Gehäusen, Einbauplatten, Wänden, Umhüllungen und Verkleidungen in Niederspannungs-Schaltgerätekombinationen können daher hohe Verlustleistungen entstehen, die maßgeblich die Erwärmung der Anlagen beeinflussen. Rechnerische und experimentelle Untersuchungen haben gezeigt, dass bei typischen Anordnungen von Schienen und Umhüllungen Verlustleistungen entstehen, die bis zu 32,7% der gesamten in der Versuchsanordnung gemessenen Verlustleistungen betragen. Sind die Ergebnisse der untersuchten Wärmequellen in die Wärmenetze der verschiedenen Betriebsmittel von Niederspannungs-Schaltgerätekombinationen integriert, ermöglichen die aufgebauten Wärmenetze die Berechnung von Temperaturen mit geringen Abweichungen (+4,4 K, -3,5 K) verglichen mit gemessenen Temperaturen. Mit den verifizierten und modularisierten Wärmenetzen der Betriebsmittel ist eine Möglichkeit geschaffen, Wärmenetze von Niederspannungs-Schaltgerätekombinationen effizient und wirtschaftlich aufzubauen.:1 Einleitung 1 2 Problemstellung 2 2.1 Stand der Technik / Ausgangssituation 2 2.2 Normen zur Erwärmung 3 2.3 Aufgabenstellung 5 2.4 Aufbau der Versuchsanlage 7 3 Grundlagen der Erwärmungsberechnung 11 3.1 Erzeugte Wärmeleistungen 11 3.2 Wärmeübertragung 17 3.3 Erwärmungsberechnung mit Wärmenetzen 39 4 Grundlagen zur Stromverdrängung 43 4.1 Stromdichteverteilung im Vollzylinder 43 4.2 Stromverdrängung und der Leistungsfaktor k 48 5 Untersuchungen zu den Wärmequellen 54 5.1 Stromwärmeverluste in den elektrischen Leiter von Sammel- und Feldverteilerschienen 57 5.2 Stromwärmeverluste in Schaltgeräten und zugehörigen Betriebsmitteln 90 5.3 Wirbelstrom- und Hystereseverluste in Metallteilen 105 6 Wärmenetze für die Betriebsmittel einer Niederspannungs- Schaltgerätekombination 126 7 Wärmenetz einer Niederspannungs-Schaltgerätekombination 148 8 Zusammenfassung und Ausblick 155 9 Literaturverzeichnis 158 10 Anhang 163 / In low-voltage engineering the systems for transmission and distribution of electric energy are named as low-voltage switchgear and controlgear assemblies. The systems have to perform their functions maintenance free as much as possible for a period of some decades. To achieve a long-time stable operation, the systems have to be designed thermally at least according to standards. In this thesis the thermal network method is used to calculate the heating of low-voltage switchgear and controlgear assemblies reliably and efficiently. The thermal network method simulates the processes of heating by heat sources, temperature sources thermal resistors and thermal capacities. The thermal power losses which are produced in the heat sources of the systems have significant influence on the heating of switchgear and controlgear assemblies. The dominant heat sources (main heat sources) within low-voltage switchgear and controlgear assemblies are researched at this thesis and the results are integrated to the thermal network method. The results are used to calculate the heating of various electrical components of a low-voltage switchgear and controlgear assembly using the thermal network method and verified by means of experiments. The thermal networks of the individual components are interconnected to form the overall thermal network of a low-voltage switchgear and controlgear assembly. The temperatures computed with this thermal network are then verified by experiments at the test setup of a low-voltage switchgear and controlgear assembly. In low-voltage switchgear and controlgear assemblies one of the main heat sources are the ohmic losses in the current paths of the main busbars and the distribution busbars. If the busbars are loaded with a three-phase current, the generated power losses of every individual subconductors are significantly influenced by the current displacement due to the skin effect and the superposed proximity effect. The power losses of each individual subconductor differ by the power factor k3~ compared to a DC load. For three-phase busbar systems with several subconductors there is only insufficient information on the power factor k3~ which takes into account the current displacement by the skin effect and the proximity effect. In this thesis, FEM models were developed to calculate the power factor k3~ for different busbar systems. The results were verified by experimental investigations. The installed electrical devices for switching, isolating and protection (e. g. circuit breakers, disconnectors, devices for disconnecting and fuses) are further main heat sources in low-voltage switchgear and controlgear assemblies. In addition to the main switching contacts themselves, thermal protection trips and the fuses are the main heat sources in the current paths of the switching devices. In order to calculate the heating of the electrical devices properly, the structure of the current paths and the distribution of the electrical resistances have to be known. In general these resistances can only determine by measuring. On one hand, it was found that the measured resistances vary widely even inside the same device. On the other hand, the resistances of the switching contacts are dominating, that up to 47 % of the entire power losses of a molded case circuit breaker can be generated there. Conditioned by the more and more compact design of the switchgears, the three-phase fields of the main busbars causes high magnetic fields at the surrounding metallic components. High power losses can therefore occur in housings, panels, walls, casings and enclosures in low-voltage switchgear and controlgear assemblies, which have a significant influence on the heating of the systems. Computational and experimental investigations have shown that typical arrangements of busbars and enclosures result in power losses of up to 32.7% of the total power losses measured in the test setup. If the results of the investigated heat sources are integrated into the networks of the various equipment of low-voltage switchgear and controlgear assemblies, the thermal networks set up enable the calculation of temperatures with small deviations (+4.4 K, -3.5 K) compared with measured temperatures. The verified and modularised thermal networks of the equipment provide an efficient and economical way of setting up heating networks of low-voltage switchgear and controlgear assemblies.:1 Einleitung 1 2 Problemstellung 2 2.1 Stand der Technik / Ausgangssituation 2 2.2 Normen zur Erwärmung 3 2.3 Aufgabenstellung 5 2.4 Aufbau der Versuchsanlage 7 3 Grundlagen der Erwärmungsberechnung 11 3.1 Erzeugte Wärmeleistungen 11 3.2 Wärmeübertragung 17 3.3 Erwärmungsberechnung mit Wärmenetzen 39 4 Grundlagen zur Stromverdrängung 43 4.1 Stromdichteverteilung im Vollzylinder 43 4.2 Stromverdrängung und der Leistungsfaktor k 48 5 Untersuchungen zu den Wärmequellen 54 5.1 Stromwärmeverluste in den elektrischen Leiter von Sammel- und Feldverteilerschienen 57 5.2 Stromwärmeverluste in Schaltgeräten und zugehörigen Betriebsmitteln 90 5.3 Wirbelstrom- und Hystereseverluste in Metallteilen 105 6 Wärmenetze für die Betriebsmittel einer Niederspannungs- Schaltgerätekombination 126 7 Wärmenetz einer Niederspannungs-Schaltgerätekombination 148 8 Zusammenfassung und Ausblick 155 9 Literaturverzeichnis 158 10 Anhang 163

Page generated in 0.0326 seconds