• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 165
  • 12
  • 1
  • Tagged with
  • 177
  • 78
  • 71
  • 31
  • 30
  • 27
  • 24
  • 22
  • 21
  • 19
  • 19
  • 19
  • 17
  • 16
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Alterações topográficas da córnea em pacientes com cérato-conjuntivite vernal. / Corneal topographic changes in patients with vernal keratoconjunctivitis.

Paulo Elias Corrêa Dantas 18 January 2002 (has links)
Doença alérgica ocular acomete cerca de ¼ da população mundial. Dentro do espectro da doença alérgica ocular, a cérato-conjuntivite vernal, que afeta principalmente crianças, pode apresentar-se sob forma severa e persistente, levando a dano do tecido corneal e comprometimento da função visual. Traumatismo epitelial crônico, induzido pelo ato de coçar os olhos, associado ao intenso prurido ocular tem sido apontado como fator de risco importante na patogênese do ceratocone. Pode estimular a apoptose prematura dos ceratócitos, provocando mudanças estruturais do estroma da córnea. A associação de cérato-conjuntivite vernal e ceratocone tem sido apontada como freqüente na literatura oftalmológica através de estudos descritivos e qualitativos, que, entretanto, não auxiliam na detecção precoce da doença ectásica corneal, prejudicando sua análise epidemiológica, seu estudo genético e a definição de sua patogênese. Propôs-se estudo clínico caso-controle de pacientes com cérato-conjuntivite vernal do Ambulatório de Alergia Ocular do Departamento de Oftalmologia da Santa Casa de São Paulo, com finalidade de obter-se, por meio da análise topográfica computadorizada de córnea utilizando-se de descritor quantitativo da superfície anterior da córnea (sumário diagnóstico de Holladay), informações sobre as alterações topográficas da superfície anterior da córnea, que pudessem determinar a freqüência da associação entre cérato-conjuntivite vernal e ceratocone, além de seus efeitos sobre o desempenho da visão destes pacientes. Os resultados obtidos neste estudo mostram alta freqüência de ceratocone em pacientes com cérato-conjuntivite vernal. A performance visual destes pacientes é influenciada pelas aberrações provocadas por alterações da asfericidade corneal e de outras variáveis topográficas. / Allergic ocular disease affects ¼ of the world population. Inside the spectrum of the allergic ocular disease, vernal keratoconjunctivitis, that affects mostly children, may present as severe and persistent form, leading to corneal tissue damage and disturbing visual function. Chronic epithelial trauma, provoked by eye rubbing due to intense ocular itching, has been postulated as an important risk factor in the pathogenesis of keratoconus. It may induce early keratocyte apoptosis that results in structural changes to the corneal stroma. The association of keratoconus with vernal keratoconjunctivitis has been observed to be frequent in the ophthalmological literature by descriptive and qualitative studies, unable to detect earlier forms of this ectatic corneal disease, weakening epidemiological analysis, genetic studies and the definition of its pathogenesis. We proposed a case-control clinical study of patients with vernal keratoconjunctivitis from the Ambulatory of Ocular Allergy of the Department of Ophthalmology of Santa Casa of São Paulo, aiming for information on the anterior corneal curvature and visual performance, using a quantitative descriptor analyzer (Holladay Diagnostic Summary). The results suggest high frequency of the keratoconus in patients with vernal keratoconjunctivitis. The visual performance is affected by the induced aberration caused by changed corneal asphericity and other topographic variables.
52

Comparação prospectiva e randomizada entre DisCo Visc e hidroxipropilmetilcelulose 2% durante a facoemulsificação / Prospective randomized comparison of DisCoVisc and 2% hydroxypropylmethilcellulose in phacoemulsification

Rodrigo França de Espindola 16 October 2015 (has links)
INTRODUÇÃO: Comparar duas soluções viscoelásticas, ácido hialurônico 1,6%/sulfato de condroitina 4% (DisCoVisc®, Alcon Laboratórios, EUA) e hidroxipropilmetilcelulose 2% (HPMC, Ophthalmos, Brasil), com relação ao desempenho durante a facoemulsificação (FACO) e o implante de lente intraocular. MÉTODOS: Foi realizado um ensaio clínico randomizado, envolvendo 78 olhos (39 pacientes) submetidos à FACO bilateral, por um único cirurgião. Os pacientes foram randomizados para receber DisCoVisc ou HPMC no primeiro olho. O olho contralateral foi operado mais tarde recebendo a outra solução viscoelástica em todas as etapas da cirurgia. Examinadores mascarados realizaram as avaliações pré e pósoperatórias (5, 24 e 48 horas; 7 e 14 dias; 3 e 6 meses), incluindo a medida da pressão intraocular (PIO), espessura cornena central (ECC) e acuidade visual corrigida. A densidade endotelial foi realizada no pré-operatório e ao final do seguimento (6 meses). Variáveis intraoperatórias incluíram medidas da quantidade total de solução viscoelástica, tempo de ultrassom durante a FACO e tempo para a retirada completa da solução do olho. RESULTADOS: A densidade endotelial foi estatisticamente superior com DisCoVisc (2.214 ± 372 cel/mm2) do que com HPMC (2.032 ± 460 cel/mm2) ao final do seguimento (p = 0,001). Uma redução média de 7% e de 15%, respectivamente. Não houve diferença estatística entre as soluções viscoelásticas com relação a densidade da catarata (p = 0,363) e o tempo de ultrassom (p = 0,456). O tempo de aspiração da HPMC (0,22 ± 0,09 min) foi significativamente maior que o DisCoVisc (0,17 ± 0,06 min) (p = 0,001) e a quantidade de viscoelástico utilizada foi maior com a HPMC (1,35 ± 0,20 ml) do que com DisCoVisc (0,89 ± 0,11 ml) (p < 0,001). Não houve diferença estatisticamente significativa entre as soluções quanto a ECC e a PIO durante o seguimento. CONCLUSÕES: A densidade endotelial ao final do estudo foi significativamente maior com o uso de DisCoVisc, o que pode representar uma melhor proteção endotelial. Foi necessário uma menor quantidade de DisCoVisc e um tempo de aspiração menor durante a FACO com essa solução viscoelástica / INTRODUCTION: To compare two ophthalmic viscosurgical devices (OVDs), 1.6% hyaluronic acid/4% chondroitin sulfate (DisCoVisc®, Alcon Lab., USA) and 2% hydroxypropylmethylcellulose (HPMC, Ophthalmos, Brazil), in terms of their overall performance during phacoemulsification (PHACO) and intraocular lens implantation. METHODS: This prospective, randomized clinical trial comprised 78 eyes (39 patients) that underwent PHACO by the same surgeon. Patients were randomly assigned to receive DisCoVisc or HPMC on the first eye. The other eye was treated later and received the other OVD. Masked examiners measured intraocular pressure (IOP), central corneal thickness (CCT) and best-corrected visual acuity. The corneal endothelial cell density was measured at baseline and at 6 months postoperatively. Intraoperative variables include the total amount of the OVD, ultrasound and washout times. RESULTS: Corneal endothelial cell density was significantly higher with DisCoVisc (2.214 ± 372 cell/mm2) than HPMC (2.032 ± 460 cell/mm2) at the end of follow-up (p = 0.001). A mean reduction of 7% and 15%, respectively. There were no statistically significant differences between OVDs in terms of cataract density (p = 0.363) or ultrasound time (p = 0.456). Regarding washout time, it took longer to remove HPMC (0.22 ± 0.09 min) than DisCoVisc (0.17 ± 0.06 min) (p = 0.001), and the amount of viscoelastic material used was greater with HPMC (1.35 ± 0.20 ml) than DisCoVisc (0.89 ± 0.11 ml) (p < 0.001). There were no statistically significant differences between the two OVDs regarding CCT or IOP measurements at any point in time. CONCLUSION: The corneal endothelial cell loss was significantly less with DisCoVisc than HPMC, which can improve corneal endothelium protection. DisCoVisc was easier to remove after IOL implantation and fewer amounts were necessary during PHACO
53

Influência da espessura corneana na acuidade visual corrigida após transplante de córnea endotelial lamelar profundo (TCELP) / The influence of corneal thickness in visual acuity after deep lamellar endothelial keratoplasty (DLEK)

Alexandre Seminoti Marcon 07 November 2006 (has links)
Objetivo: Analisar a influência da espessura corneana central na acuidade visual (AV) corrigida após transplante de córnea endotelial lamelar profundo (TCELP). Métodos: Foram estudados de forma prospectiva 155 olhos de 127 pacientes portadores de ceratopatia bolhosa ou distrofia endotelial de Fuchs no sexto mês de pós-operatório do TCELP, entre março de 2000 e março de 2005. Foram excluídos pacientes com outras alterações oculares que justificassem baixa AV. Todos os pacientes foram submetidos à avaliação oftálmica, quando foram determinadas AV corrigida, por meio de exame refratométrico, e espessura corneana central, através da paquimetria ultra-sônica. As técnicas usada foram previamente descritas. Os olhos foram agrupados de acordo com as medidas de AV: grupo I (20/20 - 20/30), grupo II (20/40 - 20/50), grupo III (20/60 - 20/80), grupo IV (20/100 - 20/400). Para correlação com paquimetria e análise estatística, as medidas de AV foram convertidas da tabela de Snellen para a tabela logarítmica (logMAR). Foram criadas variáveis categóricas para expressar status de faixa de normalidade de espessura corneana (entre 495 e 651 ?m), usando como pontos de corte valores encontrados na literatura. Resultados: A média, o desvio padrão e a variação da paquimetria foi: grupo I (n=38) 571 ±80 um, 408 a 784 um; grupo II (n=79) 598 ±80 um, 437 a 816 um; grupo III (n=30) 605 ±99 um, 454 a 945 um e grupo IV (n=8) 607 ±120 ?m, 410 a 781 ?m. Analisando o resultado da AV e a porcentagem de casos com espessura corneana acima de 651 um, foi observada associação linear significativa (P=0,037; ?2 de tendência linear) entre o aumento da paquimetria e a piora da AV. Analisando a associação entre os grupos de AV e a porcentagem de casos com espessura corneana abaixo da faixa de normalidade (<495 um), não foi encontrada significância estatística (P=0,92; x2 de Pearson). Quando analisado o resultado visual do grupo I em relação ao resultado dos grupos II+III+IV em conjunto, observou-se que somente 13% dos casos do grupo I e 30% dos casos dos demais grupos apresentaram espessura corneana maior do que 651 ?m. Essa correlação demonstrou significância estatística limítrofe (P=0,066; x2 de Pearson com correção de Yates). Conclusão: Observou-se associação linear significativa entre piora da AV corrigida e aumento da espessura corneana central. Quando analisados somente casos com paquimetria abaixo da faixa de normalidade, não foi observada associação significativa entre piora da AV corrigida e espessura corneana central / Purpose: To analyze the influence of central corneal thickness in the corrected visual acuity (VA) after deep lamellar endothelial corneal keratoplasty (DLEK). Methods: Retrospective study of 155 eyes of 127 patients 6 months post-op DLEK between March 2000 and March 2005. These patients had been previously diagnosed with either bullous keratopathy or Fuch\'s endothelial dystrophy. Patients with other ophthalmic conditions that could cause loss of vision were excluded. All patients underwent ophthalmic evaluation to determine corrected VA by means of refraction and central corneal thickness by means of ultrasonic pachymetry. Eyes were grouped according to visual acuity into 4 groups: I (20/20 - 20/30), II (20/40 - 20/50), III (20/60 - 20/80), IV (20/100 - 20/400). For statistical analysis and corelation with pachymetry, VA measurements were converted to logMAR. Categorical variables were created to express normal range corneal thickness status (from 495 to 651 um) using values published on the literature. Results: Mean and standart deviation pachymetry values were: group I (n=38) 571 ±80 ?m, ranging from 408 to 784 um; group II (n=79) 598 ±80 um, ranging from 437 to 816 ?m; group III (n=30) 605 ±99 um, ranging from 454 to 945 um and group IV (n=8) 607 ±120 um, ranging from 410 to 781 ?m. Analyzing the VA results and the percentage of cases with corneal thickness above 651 um, a significant linear correlation between higher pachymetry and worse VA was observed (P=0.037; linear trend). Analyzing the association between the different groups and the percentage of cases with corneal thickness bellow 495 um, there was no statistical significance (P=0.92; Pearson\'s x2). When analyzing the visual results of group I compared to groups II+III+IV together, it was observed that only 13% of group I cases and 30% of cases from the other groups presented corneal thickness greater then 651 um. This correlation showed borderline statistical significance (P=0.066; Pearson\'s x2 with Yates\' correction). Conclusions: A significant linear correlation between increased corneal thickness and worse VA was observed. When analyzing only cases bellow normal pachymetry, there was no correlation between corneal thickness and worse VA
54

Avaliação do papel da conexina 43 na angiogênese, experimentalmente induzida em córnea de camundongos / Evaluation the role of connexin 43 during angiogenesis, experimentally induced in mice córnea

Rodrigues, Lucas Campos de Sá 19 May 2005 (has links)
As junções GAP são canais intercelulares responsáveis pela comunicação de células vizinhas, por onde passam pequenas moléculas e íons que mantêm a homeostasia celular. A junção GAP é formada seis proteínas, as conexinas. Na célula endotelial encontram-se as conexinas 37, 40 e 43. Nesse estudo, estimulamos a angiogênese em córnea de camundongos, através da cauterização com cristal de nitrato de prata. Foram utilizados camundongos heterozigotos para o gene da conexina 43 (Cx43+/-) e camundongos selvagens (Cx43+/+). As córneas foram analisadas 2 e 6 dias após a cauterização atravéspor meio da morfologia vascular, detecção das Cx37, Cx40, Cx43, PCNA por meio de Western Blot e avaliação ultraestrutural das células endoteliais. Como resultado obtivemos uma menor área de preenchimento vascular nos animais Cx43+/- em 2 e 6 dias após a lesão corneal, porém, em relação a extensão dos vasos não foi observado diferenças entre os grupos. Uma menor proliferação celular foi verificada através da detecção do PCNA, nos animais heterozigotos, somente após 2 dias da lesão corneal. Não houve alteração da Cx37 e Cx40 entres os grupos. A Cx43 parece ser uma conexina importante para a célula endotelial durante o processo de angiogênese. / The GAP junctions are intercellular streams responsible for the communication between close cells, which allow small molecules and ions to pass through them maintaining the cellular homeostasis. The GAP junction is formed of six proteins, the connexin. In the endothelial cell, there are the connexin 37, 40 and 43. In this study, we stimulated the angiogenesis in the mice\'s cornea through its cauterization using silver\'s crystal glass. It was used heterozygote mice to the gene of connexin 43 (Cx43+/-) and wild mice (Cx43+/+). The corneas were analyzed 2 and 6 days after the cauterization through the vascular morphology, detection of Cx37, Cx40, Cx43, PCNA through Western Blot and ultrastructural evaluation of the endothelial cells. As a result, we obtained a smaller area of vascular fillness in the animals Cx43+/- with 2 and 6 days of corneal injury, however, in regard to the extensions of the vessels, it wasn\'t observed any changes between the groups. A smaller proliferation of cells was verified, through the detection of PCNA, in the heterozygote animals only 2 days after the corneal injury. There wasn\'t any modification of the Cx37 and Cx40 between groups. The Cx43 seems to be an important connexin to the endothelial cell during the process of angiogenesis.
55

Efeitos do uso tópico da mitomicina C na prevenção e tratamento da opacidade corneana em coelhos submetidos à ceratectomia fotorrefrativa / Prophylactic and therapeutic effects of topical mitomycin C on corneal haze of rabbits submitted to photorefractive keratectomy

Vieira Netto, Marcelo 19 September 2007 (has links)
Objetivos: Determinar os efeitos celulares e o mecanismo de ação da mitomicina C tópica na prevenção e tratamento da opacidade corneana em coelhos submetidos à ceratectomia fotorrefrativa (PRK). Métodos: Foram submetidos à cirurgia de PRK 224 coelhos para correção de -9 dioptrias esféricas, associada à aplicação de mitomicina C tópica ou solução salina balanceada. O nível de opacidade corneana foi avaliado por meio de análise à lâmpada de fenda. Os animais foram sacrificados quatro horas, 24 horas, quatro semanas e seis meses após a cirurgia. A análise imunohistoquímica foi realizada com as técnicas de TUNEL e foram utilizados os anticorpos Ki67 e alpha-SMA para a análise da apoptose celular, replicação celular e formação de miofibroblastos, respectivamente. Resultados: Todos os grupos submetidos à aplicação de mitomicina C apresentaram um maior número de células positivamente marcadas pelo ensaio com TUNEL (indicando maior taxa de apoptose celular) e um menor número de células positivamente marcadas pelo anticorpo Ki67 (indicando menor taxa de replicação celular). Uma menor quantidade de miofibroblastos (células positivamente marcadas pelo anticorpo alpha-SMA) foi identificada após a aplicação profilática da mitomicina C, comparada com sua aplicação com finalidade terapêutica. Além disso, identificou-se uma zona de acelularidade no estroma anterior de córneas tratadas com mitomicina C, persistente por um período mínimo de seis meses. Conclusões: A aplicação da mitomicina C diminuiu signficativamente a formação de opacidade corneana em coelhos. Apesar da mitomicina C ter induzido uma maior apoptose de ceratócitos e miofibroblastos, seu principal mecanismo de ação, responsável pela prevenção da opacidade corneana, decorreu do bloqueio da replicação dos ceratócitos ou outras linhagens celulares progenitoras dos miofibroblastos. A aplicação da mitomicina C na concentração de 0,002% mostrou-se tão eficiente quanto sua aplicação na concentração de 0,02%. Não obstante, uma persistente diminuição da densidade de ceratócitos no estroma anterior pode representar um sinal de alerta para possíveis complicações a longo prazo / Purpose: To determine cellular effects and the mechanism through which topical mitomycin C prevents and treats corneal haze after photorefractive keratectomy (PRK) in rabbits. Methods: Minus nine diopters PRK with mitomycin C or balanced salt solution was performed in two hundred and twenty four New Zealand rabbits. Haze level was graded at the slit lamp. Rabbits were sacrificed at 4 hours, 24 hours, 4 weeks or 6 months after surgery and immunohistochemistry was performed with TUNEL assay, Ki67 and alpha-SMA to analyze keratocyte cells apoptosis, keratocyte cells replication and myofibroblast cells formation, respectively. Results: TUNEL-positive cells increased in all mitomycin C groups (representing more keratocyte cells undergoing apoptosis) while Ki67-positive cells decreased significanlty (representing a decreased keratocyte cells replication) following mitomycin C application. A greater decrease in myofibroblasts was noted with prophylactic mitomycin C treatment than therapeutic mitomycin C treatment. There was, however, an anterior stromal acellular zone in eyes treated with mitomycin C that persisted out to the maximum follow-up of 6 months. Conclusion: Mitomycin C application significantly reduced corneal haze formation in rabbits. Its treatment induces apoptosis of keratocytes and myofibroblasts, but the predominate effect in inhibiting or treating haze appears to be at the level of blocked replication of keratocytes or other progenitor cells of myofibroblasts. Treatment with 0.002% mitomycin C appears to be just as effective as higher concentrations (0.02%) in the rabbit model. However, a persistent decrease in keratocyte cells density in the anterior stroma could be a warning sign for future complications
56

Sistemas de emissão UV-A homogêneo para uso clínico de irradiação de córneas / Homogeneous UV-A emission system for clinical use for corneas irradiation

Pereira, Fernando Ramon Ayres 15 October 2010 (has links)
Este trabalho é parte de um projeto destinado a criar um equipamento médico, para ser aplicado com o protocolo de crosslinking de colágeno corneano, para o tratamento do ceratocone, do qual resultou o desenvolvimento de um sistema de irradiação UV-A de córneas para a aplicação clínica oftalmológica. O sistema desenvolvido neste trabalho consiste de um circuito de malha fechada, que estabiliza a potência luminosa emitida (com erro global, após a calibração, menor que 20% durante a emissão), possibilita seu ajuste até 5 mW (6,366 mW/\'CM POT. 2\') e permite selecionar a duração da emissão entre 10 s - 30 min. O sistema irradia com pico em 365 nm \'+ OU -\' 15 nm sendo que o design óptico proporciona spots homogêneos para três diâmetros selecionáveis: 10 mm; 8 mm; e 6 mm. O software desenvolvido tem a função de controlar todo o procedimento médico do crosslinking corneano, além de detectar falhas no sistema. Os resultados obtidos neste trabalho possibilitaram a criação de um equipamento robusto, flexível e estável, capaz de competir diretamente com os produtos internacionais comercializados mundialmente. Até a presente data tem-se conhecimento de apenas dois produtos, para mesma finalidade, comercializados em todo mundo, sendo ambos de empresas européias. Desta maneira, o sistema descrito nesta dissertação integra hoje o único aparelho de crosslinking totalmente projetado e produzido com tecnologia nacional. / This work is part of a project to create a medical device to be applied with the protocol for corneal collagen crosslinking for the treatment of keratoconus, which resulted in the development of an UV-A system for corneas irradiation for ophthalmic clinical application. The developed system consists of a closed loop circuit, which stabilizes the emitted light power (with global error, after calibration, less than 20% over the issue), allows its adjust up to 5 mW (6.366 mW/\'CM POT.2\') and allows to select the emission duration between 10 s - 30 min. The system irradiates with a peak wave length at 365 nm \'+ OU -\' 15 nm and the optical design provides homogeneous spots for three selectable diameter: 10 mm, 8 mm and 6 mm. The developed software has the function of controlling the medical procedure of corneal crosslinking, and detect system failures. The results of this work enabled the creation of a robust equipment, flexible, and stable that can compete directly with international products marketed worldwide. Until the present date, there has been aware of only two products for the same purpose, marketed worldwide, both from European companies. Thus, the system described in this dissertation integrates now the only unit of crosslinking completely designed and produced with national technology.
57

Ceratoplastia lamelar em cães usando membrana amniótica eqüina. Estudo clínico e morfológico / Lamelar keratoplasty of dogs using equine amniotic membrane. Clinical and morphological study

Azevedo, Andréa Barbosa de 22 June 2006 (has links)
A membrana amniótica tem se consolidado no tratamento das afecções da superfície ocular. Assim, o objetivo deste estudo foi avaliar a viabilidade e a eficácia do implante de MA eqüina, preservada em glicerina a 98%, na reparação de ceratoplastias lamelares em cães, por meio do estudo da avaliação clínica pós-operatória dos animais, do tempo de cicatrização, da reconstrução da arquitetura da córnea, da resposta inflamatória, e da composição colágena do estroma corneal no local do implante. Foram selecionados 12 cães, sem raça definida, machos ou fêmeas, divididos em quatro grupos de três, que tiveram tempos de observação distintos: 2, 7, 21 e 40 dias. Foi realizada ceratoplastia lamelar de 5 mm de diâmetro em um dos olhos de cada animal, seguida da aplicação do implante de membrana amniótica eqüina de 6 mm. Durante o período de observação, exame clínico oftalmológico foi realizado nos cães, com intervalos de 48 horas e ao final deste período, foram submetidos á eutanásia. Os olhos em estudo foram enucleados e fixados para posterior análise. Foram utilizados três métodos de coloração para o estudo histológico do tecido implantado: hematoxilina-eosina (HE), ácido periódico de Schiff (PAS) e picrossirius. Além disso, procedeu-se a imunomarcação para colágenos tipo I, III, e V, com uso de pepsina para digestão das fibras colágenas heterotípicas exposição dos epítopos. Clinicamente os implantes foram completamente epitelizados em aproximadamente 10 dias, os neovasos apresentaram involução progressiva a partir dos 20 dias de pós-operatório, estando ausentes ao final dos 40 dias de observação, restando apenas uma nébula no local da lesão. À microscopia óptica, observou-se resposta inflamatória moderada, presença de epitélio pavimentoso estratificado aos sete dias e epitelização completa aos 21 dias. Aos 40 dias a membrana basal do epitélio apresentou-se reconstituída. O colágeno tipo I teve sua expressão no estroma intensificada aos 21 dias de pós- operatório. O colágeno tipo III está presente na membrana amniótica, sua a ausência no local do implante, aos 21 dias, mostrou remodelamento do tecido implantado. O colágeno tipo V, presente no estroma da córnea, teve sua expressão aumentada aos 7 e 21 dias, retornando à distribuição normal aos 40 dias de pós-operatório. Assim concluí-se que: a membrana amniótica eqüina é viável como implante em córnea de cão, sendo incorporada ao estroma, resultando em restabelecimento parcial da transparência no local de implante; o colágeno do tecido implantado é remodelado e substituído já aos 21 dias de pós-operatório; a pepsina foi eficiente na digestão das fibras e exposição dos epítopos dos colágenos nas fibras heterotípicas / The amniotic membrane has consecrated itself in the treatment of ocular surface diseases. The objective of this study was to evaluate the efficiency and viability of the equine amniotic membrane graft, preserved in glycerin at 98%, in the lamellar keroplasty recovery in dogs. Evaluation was based on clinical post-surgical exam, healing time, corneal architectural reconstruction, inflammatory response and collagen composition of the corneal stroma at the graft site. Twelve mixed-breed, male and female dogs were divided into four groups of three dogs. Each group was submitted to different observation periods of 2, 7, 21 and 40 days. Each dog was submitted to a 5 mm lamellar keratoplasty in one eye, followed by a 6 mm equine amniotic membrane graft. Each animal was submitted to clinical ophthalmologic exam every 48 hours. At the end of the evaluation period, the animal was euthanized and the grafted eye was removed and fixated for posterior analysis. For the histological study of the tissue graft, three methods of coloration were used: hematoxylin eosin (HE), periodic acid of Schiff (PAS) and picrosirius. Immunolocalization for the collagen types I, III and V using pepsin for fiber digestion of heterotypic fibrils and epitope exposure, was made. Clinically, the grafts were completely epithelized in approximately 10 days and neovascularization regressed progressively 20 days after surgery, being completely absent after 40 days, when only a nebula remained at the graft site. Optic microscopy revealed mild inflammatory response and presence of stratified pavement epithelium after 7 days and complete epithelization 21 days after surgery. At the end of 40 days the basal membrane was reconstituted. Type I collagen had its expression in the stroma intensified 21 days after the surgery. By day 21 the absence of collagen III in the corneal stroma showed graft remodeling, since this was formerly present in the amniotic membrane. The expression of type V fiber in the corneal stroma showed a mildly intensified expression at 7 and 21 days of observation, but returned to its normal distribution 40 days after surgery. Conclusion was that the equine amniotic membrane is a viable graft for the dog\'s cornea as it is incorporated to the stroma, resulting in partial transparency at the site of the graft. Twenty-one days after surgery, collagen from the graft is already remodeled and substituted. Pepsin is efficient for fiber digestion and collagen epitope exposure in heterotypical fibers.
58

Sistemas de emissão UV-A homogêneo para uso clínico de irradiação de córneas / Homogeneous UV-A emission system for clinical use for corneas irradiation

Fernando Ramon Ayres Pereira 15 October 2010 (has links)
Este trabalho é parte de um projeto destinado a criar um equipamento médico, para ser aplicado com o protocolo de crosslinking de colágeno corneano, para o tratamento do ceratocone, do qual resultou o desenvolvimento de um sistema de irradiação UV-A de córneas para a aplicação clínica oftalmológica. O sistema desenvolvido neste trabalho consiste de um circuito de malha fechada, que estabiliza a potência luminosa emitida (com erro global, após a calibração, menor que 20% durante a emissão), possibilita seu ajuste até 5 mW (6,366 mW/\'CM POT. 2\') e permite selecionar a duração da emissão entre 10 s - 30 min. O sistema irradia com pico em 365 nm \'+ OU -\' 15 nm sendo que o design óptico proporciona spots homogêneos para três diâmetros selecionáveis: 10 mm; 8 mm; e 6 mm. O software desenvolvido tem a função de controlar todo o procedimento médico do crosslinking corneano, além de detectar falhas no sistema. Os resultados obtidos neste trabalho possibilitaram a criação de um equipamento robusto, flexível e estável, capaz de competir diretamente com os produtos internacionais comercializados mundialmente. Até a presente data tem-se conhecimento de apenas dois produtos, para mesma finalidade, comercializados em todo mundo, sendo ambos de empresas européias. Desta maneira, o sistema descrito nesta dissertação integra hoje o único aparelho de crosslinking totalmente projetado e produzido com tecnologia nacional. / This work is part of a project to create a medical device to be applied with the protocol for corneal collagen crosslinking for the treatment of keratoconus, which resulted in the development of an UV-A system for corneas irradiation for ophthalmic clinical application. The developed system consists of a closed loop circuit, which stabilizes the emitted light power (with global error, after calibration, less than 20% over the issue), allows its adjust up to 5 mW (6.366 mW/\'CM POT.2\') and allows to select the emission duration between 10 s - 30 min. The system irradiates with a peak wave length at 365 nm \'+ OU -\' 15 nm and the optical design provides homogeneous spots for three selectable diameter: 10 mm, 8 mm and 6 mm. The developed software has the function of controlling the medical procedure of corneal crosslinking, and detect system failures. The results of this work enabled the creation of a robust equipment, flexible, and stable that can compete directly with international products marketed worldwide. Until the present date, there has been aware of only two products for the same purpose, marketed worldwide, both from European companies. Thus, the system described in this dissertation integrates now the only unit of crosslinking completely designed and produced with national technology.
59

Omento alógeno de coelho (tecido ou cultivo) associado a membrana amniótica de cão na ceratoplastia lamelar em coelhos /

Barros, Séfora Vieira da Silva Gouvêa de. January 2014 (has links)
Orientador: José Luiz Laus / Banca: Paola Castro Moraes / Banca: Luís Gustavo Gosuen Gonçalves Dias / Banca: João Antônio Tadeu Pigatto / Banca: Cláudia Valéria Seullner Brandão / Resumo: O omento, tecido gorduroso rico em células tronco mesenquimais, expressa fatores de crescimento, que atuam na regeneração tecidual, tornando-o atrativo para utilização em medicina regenerativa. Não há relatos, todavia, quanto à investigação sobre células do omento na cirurgia regenerativa em oftalmologia. Avaliaram-se os efeitos clínicos e à microscópia do omento com membrana amniótica na reparação da córnea de coelhos submetidos a ceratectomia. Duas modalidades foram avaliadas. Na primeira, o omento foi coberto com membrana amniótica imediatamente à sua implantação na córnea (grupo OM); na segunda, a membrana amniótica foi colonizada por células progenitoras extraídas do omento e transplantadas para a córnea (grupo OMC). Os efeitos clínicos foram avaliados a partir de dados coletados por até 60 dias de pós-operatório. A incidência e a prevalência de quemose foram maiores no grupo OM (p<0,05). O grupo OMC mostrou mais incidência de blefarospasmo (p<0,001). À microscopia de luz, encontrou-se reparação corneal gradativa em ambos os grupos, com reepitelização ao 100 de pós-operatótio. Aos 60 dias da avaliação, todas as córneas estavam reparadas, entretanto, no grupo OMC constatou-se vascularização. Proliferação celular acentuada foi observada com o ki-67, nos estágios finais do processo de reparação de córneas que receberam MA contendo células do omento (grupo OMC). Somente no grupo OMC, a reparação corneal sem tranparência foi alcançada / Abstract: The omentum, a fatty tissue rich in mesenchymal stem cells, expresses growth factors that act in tissue regeneration, making it attractive for use in regenerative medicine. To our knowledge, reports that investigate the use of omentum cells in ophthalmology have yet to be published. The purpose of this study was to assess the clinical and microscopic effects of omentum associated with amniotic membrane on the repair of rabbit cornea submitted to keratectomy. Two methods were evaluated; in the first, the omentum was covered with amniotic membrane immediately following its implantation on the cornea (OM group), while in the second, the amniotic membrane was colonized by omental progenitor cells and transplanted to the cornea (OMC group). Clinical parameters were evaluated from data collected up to 60 days postoperatively. The incidence and prevalence of chemosis were higher in the OM group (p<0.05). The OMC group showed greater incidence of blepharospasm (p<0.001). Under light microscopy, the absence of epithelium in the lesioned area and stromal disorganization were observed in the early postoperative period. After 60 days of evaluation, all the corneas were repaired. Intense cell proliferation was detected with Ki-67, in the final stages of the repair process, where amniotic membrane containing omental progenitor cells was transplanted to the corneas. The use of omentum and its cells, in association with amniotic membrane, favored the repair of the cornea and did not induce complications / Doutor
60

Avaliação do papel da conexina 43 na angiogênese, experimentalmente induzida em córnea de camundongos / Evaluation the role of connexin 43 during angiogenesis, experimentally induced in mice córnea

Lucas Campos de Sá Rodrigues 19 May 2005 (has links)
As junções GAP são canais intercelulares responsáveis pela comunicação de células vizinhas, por onde passam pequenas moléculas e íons que mantêm a homeostasia celular. A junção GAP é formada seis proteínas, as conexinas. Na célula endotelial encontram-se as conexinas 37, 40 e 43. Nesse estudo, estimulamos a angiogênese em córnea de camundongos, através da cauterização com cristal de nitrato de prata. Foram utilizados camundongos heterozigotos para o gene da conexina 43 (Cx43+/-) e camundongos selvagens (Cx43+/+). As córneas foram analisadas 2 e 6 dias após a cauterização atravéspor meio da morfologia vascular, detecção das Cx37, Cx40, Cx43, PCNA por meio de Western Blot e avaliação ultraestrutural das células endoteliais. Como resultado obtivemos uma menor área de preenchimento vascular nos animais Cx43+/- em 2 e 6 dias após a lesão corneal, porém, em relação a extensão dos vasos não foi observado diferenças entre os grupos. Uma menor proliferação celular foi verificada através da detecção do PCNA, nos animais heterozigotos, somente após 2 dias da lesão corneal. Não houve alteração da Cx37 e Cx40 entres os grupos. A Cx43 parece ser uma conexina importante para a célula endotelial durante o processo de angiogênese. / The GAP junctions are intercellular streams responsible for the communication between close cells, which allow small molecules and ions to pass through them maintaining the cellular homeostasis. The GAP junction is formed of six proteins, the connexin. In the endothelial cell, there are the connexin 37, 40 and 43. In this study, we stimulated the angiogenesis in the mice\'s cornea through its cauterization using silver\'s crystal glass. It was used heterozygote mice to the gene of connexin 43 (Cx43+/-) and wild mice (Cx43+/+). The corneas were analyzed 2 and 6 days after the cauterization through the vascular morphology, detection of Cx37, Cx40, Cx43, PCNA through Western Blot and ultrastructural evaluation of the endothelial cells. As a result, we obtained a smaller area of vascular fillness in the animals Cx43+/- with 2 and 6 days of corneal injury, however, in regard to the extensions of the vessels, it wasn\'t observed any changes between the groups. A smaller proliferation of cells was verified, through the detection of PCNA, in the heterozygote animals only 2 days after the corneal injury. There wasn\'t any modification of the Cx37 and Cx40 between groups. The Cx43 seems to be an important connexin to the endothelial cell during the process of angiogenesis.

Page generated in 0.047 seconds