• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 64
  • 39
  • 7
  • 7
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 132
  • 55
  • 26
  • 17
  • 16
  • 16
  • 16
  • 15
  • 14
  • 14
  • 13
  • 13
  • 13
  • 13
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Avaliação de parâmetros clínicos relacionados com a longevidade de restaurações cerâmicas livres de metal / Evaluation of clinical parameters to associated with longevity in metal free ceramic restorations

Frederico dos Reis Goyatá 25 August 2010 (has links)
Proporcionar longevidade clínica às restaurações cerâmicas deve ser um dos objetivos principais dos cirurgiões-dentistas ao realizar um tratamento protético. Objetivo: Correlacionar a influência do tratamento interno do substrato cerâmico e do tipo de polimento da superfície cerâmica externa com a efetividade clínica de restaurações com sistemas cerâmicos livres de metal. Métodos: Foram elaborados quatro artigos científicos. No Capítulo 1, apresentou-se um estudo de revisão da literatura a respeito dos métodos de tratamento de superfície para as cerâmicas reforçadas por óxido de zircônia e a implicação clínica deste procedimento na resistência da união deste sistema cerâmico quando realizada cimentação adesiva. Os Capítulos de 2 a 4 são representativos de trabalhos in vitro. No Capítulo 2, foi delineado um experimento com o objetivo de avaliar a influência do tratamento da superfície interna da cerâmica e do tipo de cimento (resinoso dual ou autoadesivo) sobre a resistência da união da interface cerâmicacimento por meio de ensaio de microcisalhamento. Os tratamentos de superfície avaliados foram: condicionamento com ácido fluorídrico a 10%, jateamento com óxido de alumínio 110μm, silicatização e junção de jateamento com óxido de alumínio 110μm e aplicação de um agente silano específicos. O teste foi realizado após o período de 24 horas e os resultados expressos em MPa. Adicionalmente, foi avaliada quantitativamente e qualitativamente a modificação promovida na superfície interna do substrato cerâmico por cada um dos tratamentos de superfície avaliados. No Capítulo 3, o mesmo delineamento executado no Capítulo 2 foi realizado, porém avaliando-se a resistência à degradação hidrolítica promovida pelos mesmos métodos de tratamento da superfície interna da cerâmica, com a realização do ensaio de resistência da união ao microcisalhamento após 24 horas e seis meses de armazenagem em água. No Capítulo 4, foi avaliada a eficácia de diferentes métodos de polimento da superfície cerâmica externa por meio de um ensaio de rugosidade de superfície e microscopia de força atômica, sendo ainda realizada a comparação entre os sistemas cerâmicos pelo ensaio de resistência à tração diametral. Conclusões: Com este trabalho foi possível determinar a importância do tratamento da superfície interna das cerâmicas previamente à cimentação adesiva, objetivando aprimorar a resistência da união da interface cerâmica-cimento, conferindo longevidade às restaurações cerâmicas. Com este propósito, para sistemas cerâmicos reforçados por zircônia, tratamentos de superfície que promovam modificações mecânicas e químicas da superfície cerâmica devem ser utilizados. Também foi possível observar que as restaurações cerâmicas depois de cimentadas e ajustadas clinicamente, devem ser submetidas a técnicas de polimento, sendo que a efetividade desta etapa é dependente da técnica de polimento executada. / Make the clinical longevity to ceramic restorations has must been a principal objective in prosthetic treatment realized for a dentist. Purpose: Correlation the influence of internal treatment in ceramic substrate and polishing method to ceramic external surface with clinical effectiveness in the metal free ceramic systems. Methods: Was elaborated four scientific articles. In the chapter one, present a literature review study with describes the treatment surface methods to ceramics reinforced to zirconium oxide and the clinical importance this procedure to the bond strength when realized adhesive cementation with ceramic system. The chapter two at four represented in vitro studies. In the chapter two, was delineated a experiment with the objective to evaluated the influence internal treatment in ceramic and the type of cement (dual cure resin and self adhesive) on the bond strength in interface ceramic-cement with microshear test. The surface treatments was: hydrofluoric acid conditioned, sandblasting using aluminum oxide 110μm, silica coating and sandblasting using aluminum oxide 110μm associated with silane agent specified. The test was performed after 24 hours and results presents in Mpa. In addition, was a quantitative and qualitatively evaluation the modification to improved in internal surface in ceramic substrate for the each surface treatment evaluated. In the chapter three, was realized the study assemble the chapter two, therefore evaluated the hydrophilic degradation improved to surface treatment internal ceramic with the microshear test after 24 hours and six months in water storage. In the chapter four, the efficacy in different polishing methods of external surface ceramic was evaluated by the surface roughness test and atomic force microscope, being even performed comparison between ceramic systems and the experiment of the diametral tensile strength. Conclusions: In this study, was possible to determinate the importance of internal surface treatment in ceramics previously adhesive cementation with objective the best bond strength in ceramic-cement interface to obtained longevity in ceramic restorations. With this objective, to ceramics reinforced to zirconium oxide, treatments surface that improve mechanical and chemistry modification to ceramic surface must be realized. Was possible too observed that ceramic restorations after cementations and clinical adjustments must be submitted the polishing techniques where the effectiveness is depended to polishing technique realized.
82

Avaliação do desajuste vertical e da espessura de película de infra-estruturas de três sistemas cerâmicos / Evaluation of vertical misfit and film thickness of three ceramic systems copings

Rodrigo Trentin Alves de Lima 23 May 2005 (has links)
O desenvolvimento de novos sistemas cerâmicos propicia a possibilidade de escolha do tipo de restauração que se deseje utilizar. Entretanto, os benefícios advindos deste progresso devem ser avaliados frente à possibilidade de comportamento clínico insatisfatório. Este trabalho se propõe a avaliar infra-estruturas cerâmicas quanto à influência do ajuste interno na adaptação, o desajuste vertical após a simulação da cimentação, a espessura de película nas superfícies axiais e oclusal e a ocorrência de assentamento oblíquo. Um troquel-padrão metálico com preparo para coroa total em pré-molar superior foi confeccionado e trinta troquéis de gesso foram obtidos e dividos em três grupos de dez espécimes cada. Sobre os troquéis de gesso foram confeccionadas infra-estruturas metálicas para o grupo MC, infra-estruturas cerâmicas In-Ceram Zirconia, para o grupo IZ, e Procera AllZircon, para o grupo PZ. As infra-estruturas tiveram sua posição, em relação ao troquel-padrão, mensurada durante ajuste interno e simulação da cimentação com silicone de consistência fluida (cimento-análogo). A película de cimento-análogo abaixo das infra-estruturas foi seccionada no sentido vestíbulo-lingual e mensurada nas paredes axiais e oclusal. A análise dos resultados demonstrou que: 1) o ajuste interno das infra-estruturas metalo-cerâmicas e In-Ceram Zirconia resultou em redução do desajuste vertical; 2) o desajuste vertical das infra-estruturas Procera AllZircon foi estatisticamente diferente das infra-estruturas metalo-cerâmicas e In-Ceram Zirconia; 3) a espessura de película das infra-estruturas Procera AllZircon foi significantemente maior que das infra-estruturas metalo-cerâmicas e In-Ceram Zirconia; 4) todas as infra-estruturas apresentaram assentamento oblíquo. / The development of new ceramic systems creates the possibility of choice above the type of restoration one could mean to choose. Thus, benefits from this progress must be appraised on the possibility of unsatisfactory clinical behavior. This work intends to evaluate ceramic copings to the influence of internal adjustment on adaptation, vertical misfit after cementation, film thickness of axial and occlusal surfaces and occurrence of oblique seating. A metallic superior premolar analogue with full crown preparation was yield and thirty casts were obtained and divided into three groups of ten specimens each. Metal copings were yield for group MC and ceramics copings of In-Ceram Zirconia and Procera AllZircon were yield for group IZ and group PZ, respectively. The copings had their position, in relation to the metallic analogue, measured during adjustment and cementation with light body silicon. Cement film, below the copings, was sectioned and measured at the axial and occlusal surfaces. The analysis of the results demonstrated that: 1) internal adjustment of metal and In-Ceram Zirconia copings reduced the vertical misfit; 2) vertical misfit after cementation of Procera AllZircon copings was statistically different from metal and In-Ceram Zirconia copings; 3) film thickness of Procera AllZircon copings was significantly greater than metal and In-Ceram Zirconia copings; 4) all copings presented oblique seating.
83

Avaliação radiográfica do comportamento ósseo em relação à profundidade da linha marginal de cimentação de próteses sobre implantes Cone Morse: estudo experimental em cães / Radiographic evaluation of bone behavior in relation to the depth of the line of marginal cementation of prostheses on Morse taper implants: experimental study in dogs

Fernanda Herrera Stancari 29 March 2011 (has links)
Pouco se sabe sobre o comportamento do tecido ósseo em relação à profundidade da linha de cimentação em próteses sobre implantes. Por isso, o presente estudo radiográfico utilizou os implantes Cone Morse com o intuito de definir a posição exata na qual se pode estabelecer a profundidade da linha de cimentação protética. Foram utilizados cinco cães, os quais tiveram todos os pré-molares inferiores extraídos numa primeira fase cirúrgica. Após três meses, realizou-se a segunda fase cirúrgica na qual foi utilizada a técnica da carga imediata, com a instalação dos implantes juntamente com os pilares protéticos. Foram instalados trinta implantes numa profundidade de 3mm infra óssea e eles foram igualmente divididos entre os grupos Controle e Experimental. Os pilares protéticos tinham diferentes dimensões transmucosas de 1.5, 3.5, e 5.5mm. Isto fez com que a linha de cimentação se posicionasse a 1.5mm infra óssea, a 0.5mm supra óssea e a 2.5mm supra óssea. No grupo Controle, foi realizada a instalação dos implantes e dos pilares protéticos somente. No grupo Experimental, foi realizada a instalação dos implantes, dos pilares protéticos e, sobre estes, foram cimentados cilindros de alumina. Foram realizadas tomadas radiográficas periapicais, através da técnica do paralelismo, em todas as fases do experimento. As radiografias foram escaneadas e analisadas através do programa AutoCAD. Foram utilizados os testes estatísticos t de Student para amostras pareadas e independentes com o nível de significância de p<0.05. Os resultados mostraram que não houve diferenças estatisticamente significantes entre os grupos Controle e Experimental nas diferentes profundidades em relação ao tecido ósseo. Adicionalmente, também não houve diferenças estatisticamente significantes na crista óssea nas variações das dimensões das cintas transmucosas dos pilares testados e nas variações entre os tempos Inicial e Final do experimento no grupo Controle e no grupo Experimental. Conclui-se que não há influência da profundidade da linha de cimentação no comportamento da crista óssea e a utilização de diferentes dimensões dos pilares protéticos não altera o tecido ósseo marginal ao redor dos implantes Cone Morse. / Little is known about the behavior of bone tissue in relation to the depth of the cement line position in dental implants. Therefore, this radiographic study used the Morse taper implants in order to define the exact location in which it can be established the depth of the prosthetic cementation line. Five dogs were used and had all their lower premolars extracted in the first stage surgery. After three months, was performed a second surgical procedure in which was used the technique of immediate loading, installing together implants and abutments. Thirty implants were installed at a depth of 3 mm below the bone and they were equally divided between the Control and Experimental group. The abutments had different transmucosal dimensions of 1.5, 3.5, and 5.5mm. This meant that the depth of cementation line was positioned respectively to 1.5mm below the bone, 0.5 above the bone and 2.5mm above the bone. In the Control group, was performed the installation of implants and abutments only. In the Experimental group, was performed the installation of implants, abutments and, over these, was cemented cylinders of alumina. Periapical radiographs were taken, using the paralleling technique, in all phases of the experiment. The radiographs were scanned and analyzed with the program AutoCAD. Statistical t Student test of samples paired and independent were used with the level of significance of p<0.05. The results showed no differences statistically significants between the Control and Experimental group at different depths in relation to bone tissue. Additionally, there were no differences statistically significant in the crest bone in the variations of dimensions of the transmucosal abutments tested and in the variations between the Start and End time of the experiment in the Control and Experimental groups. It is concluded that there is no influence of the depth of cementation line on the behavior crest bone and the different dimensions of the abutment does not change the marginal bone around Morse taper implants.
84

Estudo da resistência de quatro diferentes materiais utilizados na cimentação de pinos à infiltração lateral / Study of lateral infiltration resistance of four different materials used for posts cementing

Marcio Katsuyoshi Mukai 12 August 2010 (has links)
A raspagem e o aplainamento radicular removem o cemento presente nesta área, o qual funcionaria como barreira de dentina contra a penetração de bactérias, toxinas e outros produtos vindos da superfície externa do dente. O objetivo deste estudo foi avaliar, in vitro, em dentes tratados endodonticamente, a resistência apresentada por diferentes materiais de cimentação na infiltração do azul de metileno, que poderia atravessar a dentina radicular, quando submetido a duas diferentes situações: a) raspagem e aplainamento do cemento radicular e b) remoção de cemento com pontas diamantadas. Para isso, utilizou-se 48 dentes humanos unirradiculares, cedidos pelo banco de dentes da FOUSP, tratados endodonticamente e preparados para receberem pinos. Estes foram modelados com resina acrílica para que, por meio de fundição, fossem obtidos os retentores intrarradiculares metálicos. Os dentes foram divididos em 4 grupos com 12 espécimes, e a cada um dos grupos, destinado um tipo de material diferente para a cimentação: Cimento de Zinco® (SS White, Rio de Janeiro, Rio de Janeiro, Brasil), Cimentos resinosos Panavia F® (Kuraray, Kurashiki, Okayama, Japan), Rely X U 100® (3M Dental, Seefeld, Alemanha) e Rely X Luting 2® (3M Dental, Sant Paul, Estados Unidos). Após esse procedimento, delimitaram-se duas janelas na região cervical da raiz, sendo que num dos lados o cemento foi removido com uma ponta diamantada e no lado oposto, com 40 golpes de cureta Gracey 5-6 (Neumar, São Paulo, São Paulo, Brasil) paralelos ao longo eixo do dente. Exceto nas regiões instrumentadas, o dente foi impermeabilizado externamente e exposto à solução de azul de metileno a 1% e pH 7,2 durante 48 horas. As amostras foram desgastadas no sentido do longo eixo até o maior diâmetro do pino e a área impregnada pelo corante foi digitalizada e mensurada com o programa Imagelab®. A comparação da área impregnada pelo agente traçador na película dos cimentos, nos terços cervical e médio, revelou diferenças estatisticamente significantes entre si (p < 0,05). No lado em que a dentina foi removida com broca, houve diferença estatisticamente significante quando os três materiais adesivos foram comparados com o Cimento de Zinco (SS White, Rio de Janeiro, Rio de Janeiro, Brasil). Na comparação entre os cimentos resinosos houve diferença estatisticamente significante (p<05) somente entre os cimentos Panavia F® (Kuraray, Kurashiki, Okayama, Japan) e Rely X U 100® (3M Dental, Seefeld, Alemanha) para o terço apical. Na superfície tratada com curetas periodontais, verificou-se diferença estatisticamente significante entre os grupos estudados (p < 0,05) apenas quando comparados o cimento Rely X U 100® (3M Dental, Seefeld, Alemanha) com Rely X Luting 2® (3M Dental, Sant Paul, Estados Unidos) para o terço cervical. Concluiu-se que para o tratamento com ponta diamantada, que os cimentos Panavia F® (Kuraray, Kurashiki, Okayama, Japan), Rely X U 100® (3M Dental, Seefeld, Alemanha) e Rely X Luting 2® (3M Dental, Sant Paul, Estados Unidos) têm comportamento semelhante para os terços cervical e médio, diferindo apenas no terço apical. Já para o tratamento com curetas periodontais, os cimentos Panavia F® (Kuraray, Kurashiki, Okayama, Japan), Rely X U 100® (3M Dental, Seefeld, Alemanha) e Rely X Luting 2® (3M Dental, Sant Paul, Estados Unidos) mostraram resultados similares para os terços médio e apical, diferindo apenas no terço cervical. / Scaling and root planning remove cementum present in this area, which would acts as a dentin barrier against penetration of bacterias, toxins and other products coming from the surface of the tooth. The objective of this study was to evaluate in vitro endodontically treated teeth, the resistance of different materials to methylene blue, which could cross the root dentin when submitted to two different situations: a) scaling and root planning b) removal of cementum with drills. It was used 48 human uniradicular teeth, assigned by FOUSPs teeth bank and were endodontically treated and prepared to receive pins. These were modeled with an acrylic resin in order to obtain the metallic intraradicular posts. The teeth were divided into four groups with twelve specimens. Each one of the groups received a different material for cementing: Cement of Zinc® (SS White, Rio de Janeiro, Rio de Janeiro, Brazil), Panavia F® Resin Cements (Kuraray, Kurashiki, Okayama, Japan), Rely X U 100® (3M Dental, Seefeld, Germany) and Rely X Luting 2® (3M Dental, Sant Paul, United States). After this procedure, it was delimited two windows in the cervical region of the root. One of the sides the cementum was removed with a diamond drill and on the other side, with 40 Gracey 5-6 curette strokes (Neumar, São Paulo, Brazil) parallel to the long axis of the tooth. Except on the instrumented regions, the tooth was externally sealed and exposed to a 1% methylen blue solution and pH 7.2 during 48 hours. The samples were scraped from the long axis until the largest post diameter. The impregnated area with the dye were scanned and measured with the Imagelab® program. The comparison between the impregnated area through the tracer agent on the cement film in the cervical and medium thirds revealed statistically significant differences (p<0,05). On the side where the dentin was removed with a drill, there was a statistically significant difference when the three adhesive materials were compared to the Zinc Cement (SS White, Rio de Janeiro, Rio de Janeiro, Brazil). In the comparison between the resin cements there was a statistically significant difference (p<0,05) only between the cements: Panavia F® (Kuraray, Kurashiki, Okayama, Japan) and Rely X U 100® (3M Dental, Seefeld, Germany) for the apical third. On the surface treated with periodontal curettes, it was identified a meaningful statistical difference between the studied groups (p<0,05) only when compared the cements: Rely X U 100® (3M Dental, Seefeld, Germany) with Rely X Luting 2® (3M Dental, Sant Paul, United States) for the cervical third. The conclusion was that when the treatment uses a drill, the cements: Panavia F® (Kuraray, Kurashiki, Okayama, Japan), Rely X U 100® (3M Dental, Seefeld, Germany) and Rely X Luting 2® (3M Dental, Sant Paul, United States) have similar behavior to the cervical and medium third. The unique difference comes from the apical third. On the other hand, the treatments using periodontal curettes, the cements Panavia F® (Kuraray, Kurashiki, Okayama, Japan), Rely X U 100® (3M Dental, Seefeld, Germany) and Rely X Luting 2® (3M Dental, Sant Paul, United States) resulted in similar results for the medium and apical thirds, only differing on the cervical third.
85

Técnica de cimentação em próteses sobre implantes com pilares protéticos asperizados: estudo in vitro / Cementation technique on sandblasted prosthetic implant abutments: an in vitro study

Fernando Igai 03 November 2014 (has links)
A Implantodontia proporciona tratamentos com alto grau de sucesso clínico nas reabilitações com próteses parafusadas ou cimentadas. A alta taxa de sobrevivência dos implantes, seu sucesso clínico significativo e a grande previsibilidade levaram a uma mudança de paradigma na Implantodontia atual. O uso de implantes, antes utilizados para a reposição de grandes perdas dentárias, é aplicado também para perdas parciais de dentes e até mesmo elementos unitários. Com isso a dificuldade técnica diminuiu ainda mais, consolidando o uso de próteses cimentadas sobre implantes. Desta forma a reversibilidade, que é o principal recurso das próteses parafusadas sobre implantes, não é mais decisiva na escolha do tipo de sistema de retenção. Entretanto, as próteses cimentadas apresentam desvantagens que podem levar a um fracasso do tratamento. Dentre elas o acúmulo do excesso de cimento, que pode levar a uma inflamação do tecido periimplantar com a possível perda do implante. Existem na literatura técnicas de cimentação que visam à redução do agente cimentante em excesso. Outro fator estudado é a influência da rugosidade da superfície do munhão protético na resistência ao arrancamento do elemento protético. O objetivo do estudo foi realizar uma análise da resistência ao arrancamento de coroas cimentadas sobre munhões protéticos polidos e asperizados, utilizando uma técnica experimental de cimentação. Foram confeccionados quarenta corpos de prova e formaram-se quatro grupos de estudo, de acordo com a técnica de cimentação utilizada (técnica controle e técnica experimental) e a rugosidade das paredes do munhão protético (polido e asperizado). As coroas foram cimentadas com o cimento de Fosfato de Zinco. A análise da resistência ao arrancamento foi realizada, após a ciclagem térmica dos quarenta corpos de prova, utilizando uma máquina de ensaio universal. Na análise das técnicas de cimentação pôde-se observar que não ocorreram diferenças estatisticamente significativas entre os grupos, com valores médios de resistência ao arrancamento de 157,83 N ± 22,16 N para o grupo técnica controle-superfície polida e 159,95 N ± 46,40 N para o grupo técnica experimental-superfície polida. A análise dos dados nos grupos técnica controle-superfície asperizada (626,23 N ± 34,80 N) e técnica experimental-superfície asperizada (642,62 N ± 94,00 N), também não indicaram diferenças significativas. Na análise dos grupos, comparando a rugosidade da superfície, pôde-se observar diferenças significativas, com valores de 157,83 N ± 22,16 N para o grupo técnica controle-superfície polida e 626,23 N ± 34,80 N para o grupo técnica controle-superfície asperizada. O mesmo foi observado no grupo técnica experimental-superfície polida com valores de 159,95 N ± 46,40 N e 642,62 N ± 94,00 N para o grupo técnica experimental-superfície asperizada. Conclui-se que, nas condições utilizadas neste estudo, a técnica de cimentação experimental não apresentou diferenças significativas com a técnica controle, em relação à resistência ao arrancamento, nas duas superfícies (polida e asperizada) utilizadas no estudo. A asperização das paredes axiais dos munhões levou a um aumento significativo da resistência ao arrancamento nas duas técnicas de cimentação estudadas. / The Implantology provides treatments with high clinical success rate in screw or cement retained rehabilitations. The high survival rate of the implants, its significant clinical success, and the great predictability led to a paradigm shift in current Implantology. The dental implant, previously used for replacing large teeth losses, is also applied to partial dental losses and even single tooth replacement. Therefore, technical difficulties have decreased even more, which consolidated the use of cement retained implant prosthesis. Thus the retrievability, which is the main resource of screw retained implant prostheses, is not the crucial point in the prosthesis retention selection. However, cement retained prostheses have disadvantages that can lead to treatment failure. One can mention the presence of residual excess cement, which may lead to an inflammation of the peri-implant tissue, or even a possible implant loss. There are in the literature cementation techniques that reduce the luting agent excess. Another studied factor is the influence of the prosthetic abutment surface roughness in the prosthetic element tensile strength. The aim of the study was to analyze the tensile strength of prosthetic crowns cemented on standard machined and sand blasted abutments using an experimental cementation technique. Forty specimens were fabricated and four experimental groups were formed, according to the cementation technique (control technique and experimental technique) and the prosthetic abutment roughness (standard machined and sand blasted). The crowns were cemented with zinc phosphate cement. The tensile strength analysis was performed, after the forty specimens thermal cycling, using an universal testing machine. In the cementation techniques analysis it was observed that there were no statistically significant differences between the groups, with mean tensile strength values of 157.83N±22.16N for the control technique- standard machined surface and 159.95N±46.40N for the experimental technique-standard machined surface. The data analysis of control technique-sand blasted surface group (626.23 N±34.80N) and experimental technique-sand blasted surface group (642.62 N±94.00N) also indicated no significant differences. In the group analysis, comparing the surface roughness, it was observed significant differences, with values of 157.83N±22.16N for the control technique-standard machined surface group and 626.23N±34.80N for the control technique-sand blasted surface group. The same was observed in the experimental technique-standard machined surface group with 159.95N±46.40N values and 642.62N±94.00N for the experimental technique-sand blasted surface group. It can be concluded that, under the study conditions, the experimental cementation technique showed no significant differences with the control technique, regarding tensile strength, in the two surfaces (standard machined and sand blasted) used in the study. The prosthetic abutments roughening led to a significant increase in tensile strength on the two studied cementation techniques.
86

"Estudo comparativo da resistência à infiltração que diferentes materiais resinosos utilizados na cimentação de retentores intra-radiculares oferecem à passagem de fluidos que atravessam a dentina" / Comparative study of the infiltration resistance that different resinous materials used in intra-radicular retainers foundation offer to the fluids passage that cross through the dentine.

Marcio Katsuyoshi Mukai 01 September 2005 (has links)
O Objetivo deste estudo é avaliar in vitro, a resistência que diferentes materiais resinosos têm a passagem de fluidos que atravessam a dentina na ausência de cemento radicular. Foram utilizados 60 dentes humanos cedidos pelo banco de dentes da FOUSP. Os dentes foram submetidos a tratamento endodôntico segundo a técnica de Paiva e Antoniazzi e armazenados a uma temperatura de 37°C em umidade 100% por 24 horas para o preparo do retentor intra -radicular respeitando o limite apical de 4 mm. Os retentores intra-radiculares foram modelados com resina tipo Duralay e fundidos com liga de prata e cimentados com os seguintes materiais: Oxifosfato de Zinco (SS White), Enforce (Dentsply), Panavia F (Kuraray) e Rely X (3M) . Após a cimentação, delimitou-se uma janela na região cervical da raiz onde o cemento foi removido com uma broca diamantada, a parte externa da raiz foi impermeabilizada com cianocrilato de etila e esmalte cosmético para posterior imersão em uma solução de azul de metileno a 1% por 48 horas. Decorrido este período, a camada impermeabilizante foi removida, os dentes foram desgastados no sentido mésio distal e avaliados com o programa Imagelab. A comparação da área impregnada pelo agente traçador na película dos cimentos, nos terços cervical e médio, revelou diferenças estatisticamente significantes (p < 0,01) do Panavia F (Kuraray) em relação aos outros três materiais, demonstrando a superioridade desse material no que se refere à impermeabilização do sistema de canais radiculares. Podemos concluir que dentre os materiais avaliados o cimento Panavia F (Kuraray) apresentou diferença estatisticamente significante, tanto para no segmento cervical quanto terço médio. / This study objective is to evaluate in vitro, the resistance that different resinous materials have through the fluids passage cross through the dentine in the absence of radicular cementum. 60 human teeth given by FOUSP bank of teeth were used. The teeth were submitted to endodontic treatment according to Paiva's and Antoniazzi´s technique and stored in a temperature of 37°C in humidity 100% during 24 hours for the preparation of the intra-radicular retainer, respecting the 4 mm apical limit. The intra -radicular retainers were modeled with Duralay resin type and melted with silver league and cemented with the following materials: Zinc Oxiphosfate (SS White), Enforce (Dentsply), Panavia F (Kuraray) and Rely X (3M). After the foundation, a window was delimited in the root cervical area where the cementum was removed with a diamond drill. The external part of the root was made waterproof with etile cyanocrylate and cosmetic enamel for subsequent immersion in a 1% blue methylen solution for 48 hours. Elapsed this period, the waterproof layer was removed, the teeth were consumed in the mesio-distal direction and appraised with the Imagelab software. The impregnated area by the tracer agent of the in the film of the cements comparison, in the cervical and medium thirds, revealed significant statistical differences (p <0,01) of Panavia F (Kuraray) in relation to the other three materials, demonstrating the superiority of that material in relationship to the radicular chanal “waterproofing” system. It’s possible to conclude that among the appraised materials, the Panavia F (Kuraray) cement presented significant statistical difference, in the cervical segment as well as the medium third.
87

Gas Phase Alloying and Sintering Kinetics of 3D Printed Ni-Based Structures

Khodabakhsh, Safa January 2021 (has links)
No description available.
88

TRANSITION METAL COATINGS FOR ENERGY CONVERSION AND STORAGE; ELECTROCHEMICAL AND HIGH TEMPERATURE APPLICATIONS

Falola, Bamidele Daniel 01 May 2017 (has links) (PDF)
Energy storage provides sustainability when coupled with renewable but intermittent energy sources such as solar, wave and wind power, and electrochemical supercapacitors represent a new storage technology with high power and energy density. For inclusion in supercapacitors, transition metal oxide and sulfide electrodes such as RuO2, IrO2, TiS2, and MoS2 exhibit rapid faradaic electron–transfer reactions combined with low resistance. The pseudocapacitance of RuO2 is about 720 F/g, and is 100 times greater than double-layer capacitance of activated carbon electrodes. Due to the two-dimensional layered structure of MoS2, it has proven to be an excellent electrode material for electrochemical supercapacitors. Cathodic electrodeposition of MoS2 onto glassy carbon electrodes is obtained from electrolytes containing (NH4)2MoS4 and KCl. Annealing the as-deposited Mo sulfide deposit improves the capacitance by a factor of 40x, with a maximum value of 360 F/g for 50 nm thick MoS2 films. The effects of different annealing conditions were investigated by XRD, AFM and charge storage measurements. The specific capacitance measured by cyclic voltammetry is highest for MoS2 thin films annealed at 500°C for 3h and much lower for films annealed at 700°C for 1 h. Inclusion of copper as a dopant element into electrodeposited MoS2 thin films for reducing iR drop during film charge/discharge is also studied. Thin films of Cu-doped MoS2 are deposited from aqueous electrolytes containing SCN-, which acts as a complexing agent to shift the cathodic Cu deposition potential, which is much more anodic than that of MoS2. Annealed, Cu-doped MoS2 films exhibit enhanced charge storage capability about 5x higher than undoped MoS2 films. Coal combustion is currently the largest single anthropogenic source of CO2 emissions, and due to the growing concerns about climate change, several new technologies have been developed to mitigate the problem, including oxyfuel coal combustion, which makes CO2 sequestration easier. One complication of oxyfuel coal combustion is that corrosion problems can be exacerbated due to flue gas recycling, which is employed to dilute the pure O2 feed and reduce the flame temperature. Refractory metal diffusion coatings of Ti and Zr atop P91 steel were created and tested for their ability to prevent corrosion in an oxidizing atmosphere at elevated temperature. Using pack cementation, diffusion coatings of thickness approximately 12 and 20 µm are obtained for Ti and Zr, respectively. The effects of heating to 950°C for 24 hr in 5% O2 in He are studied in situ by thermogravimetric analyses (TGA), and ex situ by SEM analyses and depth profiling by EDX. For Ti-coated, Zr-coated and uncoated P91 samples, extended heating in an oxidizing environment causes relatively thick oxide growth, but extensive oxygen penetration greater than 2.7 mm below the sample surface, and eventual oxide exfoliation, are observed only for the uncoated P91 sample. For the Ti- and Zr-coated samples, oxygen penetrates approximately 16 and 56 µm, respectively, below the surface. In situ TGA verifies that Ti-and Zr-coated P91 samples undergo far smaller mass changes during corrosion than uncoated samples, reaching close to steady state mass after approximately four hours.
89

Compositional Influences on Microtube Formation in Ni-Based Wires via the Kirkendall Effect

Zhang, Haozhi 23 August 2022 (has links)
No description available.
90

Factors Affecting the Precipitation of Quartz Under Hydrothermal Conditions

Pepple, Chris C. 11 February 2008 (has links)
No description available.

Page generated in 0.1689 seconds