• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 64
  • 39
  • 7
  • 7
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 132
  • 55
  • 26
  • 17
  • 16
  • 16
  • 16
  • 15
  • 14
  • 14
  • 13
  • 13
  • 13
  • 13
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Avaliação da adaptação marginal de restaurações cerâmicas inlay após a cimentação /

Carvalho, Cristiane Fonseca de. January 2007 (has links)
Orientador: Lafayette Nogueira Junior / Banca: Carlos Augusto Pavanelli / Banca: Paulo Sérgio Mutarelli / Resumo: O objetivo deste estudo foi avaliar e comparar a adaptação marginal de restaurações, confeccionadas em dois tipos de sistemas cerâmicos: CEREC inLab (VITA) e IPS Empress 2 (Ivoclar-Vivadent), após a cimentação com cimento resinoso RelyX (3M). Foram preparados 20 pré-molares humanos com cavidade MOD inlay, reproduzidos com silicone de adição, e obtidos modelos em gesso tipo IV, sobre os quais foram confeccionadas as restaurações conforme as recomendações dos fabricantes. Dez inlays no sistema IPS Empress 2 e 10 inlays no sistema CEREC inLab. As restaurações foram cimentadas sob pressão constante de 1,5 Kgf por 10 min, com cimento resinoso, com pré-tratamento. As desadaptações marginais foram avaliadas em MEV, com magnificação de 200x, em 50 pontos eqüidistantes. As médias foram analisadas pelo teste estatístico t(Student) de amostras dependentes.Resultando em uma diferenca estatisticamente significante entre as desadaptaçoes marginais no sistema IPS Empress (93,8'mais ou menos'15,5'mü'm)que se mostraram menores que no sistema CEREC inLab (114,4'mais ou menos'10,6'mü'm). Quando se comparou os valores médios entre as faces proximais (116,51.21,85'mü') e oclusal (112,26'mais ou menos'8,49'mü") do sistema Cerec Inlab, e faces proximais (87,12'mais ou menos'27,98,'mü') e oclusal (100,47'mais ou menos'22,23'mü')do sistema IPS Empress 2, verifica-se que esses valores não diferem estatisticamente. Ainda assim, conclui-se que as médias obtidas são aceitavéis clinicamente. / Abstract: This study has the proposal to evaluate the marginal adaptation of two system all-ceramic class II inlays one of laboratory-made heat-pressed ceramics (IPS Empress 2) and other computer-aided manufacturing ( CEREC inLab) after cementation with resin cement . Extracted human premolars were prepared to receive mesio occluso distal (MOD) ceramic inlays for 10 IPS Empress restorations and 10 CEREC inLab restorations. The impression material used was a polivinilsyloxane addition silicone by the double impression technique. The impressions of prepared teeth were cast in type IV dental stone. The restaurations were made following the manufacturer's recommendations. The inlays were luted on human premolars with resin cement in accordance with the manufacturer's recommended pré-treatment. The marginal gaps were investigated scanning electron microscopy with magnification of 200x. The results were analyzed by t (student) statistic test.The means marginal gap for IPS Empress 2 wal 93,8'mais ou menos'15,5'mü'm significantly smaller than that od 114,4'mais ou menos'10,6'mü'm calculated a the CEREC in Lab system.The gaps of the inlays at the occlusal margin and of the approximal margin showed no significantly differences in two system. It may be concluded that mensuarement value are clinically acceptable. / Mestre
102

Avaliação do destorque de dois tipos de parafusos fixadores do munhão e da resistência à tração de coroas cimentadas sobre munhões com diferentes características superficiais

Fabiane Lopes Toledo 02 September 2011 (has links)
Problemas freqüentes na prótese sobre implante são o afrouxamento do parafuso que une o munhão ao implante e a soltura da prótese cimentada. Assim, foi estudada a manutenção da força de torque, promovida por 2 diferentes parafusos fixadores de munhão, e a resistência à remoção por tração de coroas de NiCr, cimentadas ou re-cimentadas com fosfato de zinco sobre munhões com diferentes características. Numa primeira fase, foram utilizados 20 conjuntos implante/munhão/parafuso (NEODENT), constituídos de liga de Ti, nos quais existiam 10 parafusos comuns e 10 revestidos com carbono (Neotorque). A força de torque de 32 N era aplicada com um torquímetro analógico de precisão (TOHNICHI) e, para a aplicação cíclica de carga de compressão axial, foi utilizada uma máquina eletro-mecânica de fadiga, com carga de 200 N e freqüência de 2 hertz, durante 500.000 ciclos. Na segunda fase, foram usados 30 conjuntos (implante/munhão/parafuso e respectivas coroas), onde existiam apenas parafusos comuns, porém com munhões de diferentes tamanhos e aspectos superficiais: o munhão universal (MU), o personalizado original (MPO) e o personalizado irradiado (MPI). As coroas destes 2 últimos grupos já haviam sido cimentadas e tracionadas, num trabalho anterior. Todas as coroas foram agora cimentadas com fosfato de zinco e submetidas (7 dias depois) a ensaios de tração, em uma máquina universal de ensaios regulada na velocidade de 0,5 mm/min. Nas condições deste trabalho, foi possível concluir que ambos os parafusos analisados (comum e Neotorque) apresentaram comportamento semelhante, na manutenção da força de torque promovida, e que a resistência à remoção por tração de coroas, cimentadas pela primeira vez, com o munhão universal (MU), foi a menor de todas (227,83 N.cm); para os caso das recimentações, com o munhão personalizado de textura original, esta resistência apresentou valor intermediário (448,37 N.cm), tendo sido a maior de todas (1.570,76 N.cm) aquela apresentada pelo munhão personalizado que sofreu irradiação por LASER. / Frequent problems in implant prosthodontics are loosening the screw that joins the abutment to implant and the releasing of the cemented prosthesis. Thus, it was studied both the torque force mantenaince promoted by two different screws as the resistance to removal by traction of NiCr crowns, cemented or re-cemented with zinc phosphate over abutments with different characteristics. In a first phase, it were used 20 Ti alloy-made sets (composed by Neodent implant / abutment / screw), in which there were 10 slotted screws carbon-coated (Neotorque). The torque force of 32 N was applied with an analogical torque wrench (TOHNICHI) and the cyclic axial compression load with a fatigue electro-mechanical machine, with a load of 200 N and frequency of 2 Hz, over 500,000 cycles. In the second phase, it was used 30 other sets (composed by implant / abutment / screw and their crowns) where there were only common screws, but with sleeves of different size and superficial aspects: the universal abutment (MU), that personalizable with original texture (MPO) and the personalizable with a LASER treatment (MPI). Crowns of these two latter groups had already been cemented and pulled in a previous work. All crowns were here cemented with zinc phosphate and submitted (7 days later) to tensile tests in an universal testing machine set at a speed of 0.5 mm / min. In the conditions of the present work, it was concluded that both analyzed screws (common and Neotorque) behaved similarly, maintaining the torque force promoted, and that resistance to removal by traction of crowns cemented by first time with the universal abutment (MU) was the lowest of all (227.83 N.cm); for recementations, personal abutment with original texture had intermediate values resistance (448.37 N.cm), being the largest of all (1570.76 N.cm) that presented by the abutment modified by LASER irradiation.
103

Avaliação da resistência de união proporcionada por diferentes tipos de cimentos resinosos em pilares híbridos de zircônia

Lacerda, Gabriel Pinheiro 27 April 2015 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-05-05T13:56:21Z No. of bitstreams: 1 gabrielpinheirolacerda.pdf: 1840814 bytes, checksum: 711c6aedc66cee4634cf4c1d2a8d1317 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-06-07T15:38:01Z (GMT) No. of bitstreams: 1 gabrielpinheirolacerda.pdf: 1840814 bytes, checksum: 711c6aedc66cee4634cf4c1d2a8d1317 (MD5) / Made available in DSpace on 2016-06-07T15:38:01Z (GMT). No. of bitstreams: 1 gabrielpinheirolacerda.pdf: 1840814 bytes, checksum: 711c6aedc66cee4634cf4c1d2a8d1317 (MD5) Previous issue date: 2015-04-27 / O propósito deste estudo foi avaliar in vitro, a resistência de união entre os constituintes dos pilares híbridos de zircônia, comparando diferentes tipos de cimentos resinosos. Para a realização do presente estudo foram confeccionadas trinta peças de zircônia com formato anatômico de primeiro molar inferior direito. Estas foram divididas em três grupos de acordo com os cimentos resinosos a serem utilizados para cimentá-las sobre bases metálicas de titânio: Grupo A- cimento auto adesivo de dupla ativação, Grupo B- cimento de dupla ativação convencional e Grupo C- cimento quimicamente ativado. Posteriormente ao processo de cimentação, os 30 corpos de prova foram armazenados em água destilada por 24 horas em temperatura ambiente e em seguida, foram submetidos à ciclagem térmica em equipamento específico sendo submetidos a banhos em 5o C e 55o C, com 30 segundos de permanência em cada banho, tempo de deslocamento de 2 segundos, totalizando 6.000 ciclos. Os testes de ciclagem mecânica foram realizados com os corpos de prova imersos em água destilada a 37o C, com carga de 100N, frequência de 2Hz e 200.000 ciclos. Após os testes termomecânicos, os espécimes foram submetidos a testes de tração na máquina de ensaio universal EMIC DL 2000. Os valores de resistência de união foram obtidos em Quilograma Força (Kgf) para cada espécime. Os dados obtidos pelo ensaio de tração foram submetidos ao teste ANOVA, com nível de significância de 5%. Anterior a realização deste teste, os dados foram verificados quanto a sua normalidade e homocedasticidade pelos testes de Shapiro-Wilk e Bartlett, respectivamente. Por meio de um estereomicroscópio verificou-se que o modo de falha de cimentação do tipo adesiva, entre cimento resinoso e superfície de zircônia, ocorreu em todos os corpos de provas. Conclui-se que os diferentes tipos de cimentos resinosos testados neste estudo se comportaram de maneira eficiente na cimentação das duas peças dos pilares híbridos de zircônia. / Objective: The purpose of this study was to evaluate in vitro by means of tensile test, the bond strength of the constituents of zirconia abutments of two pieces in unit restorations on implants with prosthetic connections cone morse type, comparing three different types of cements resinous. Materials and Methods: Thirty zirconia pieces with the mandibular first molar format were divided into three groups according to the cement to be used to cement them on metal titanium bases: Group A- Relyx U200, Group B- Panavia F 2.0 and Group C- Multilink. Subsequently the process of cementing, the 30 specimens were stored in distilled water for 24 hours at room temperature and then were submited to thermal cycling in specific equipment undergoing baths in 5°C and 55°C, with 30 seconds remaining in each bath, 2 seconds travel time, totaling 6.000 cycles. The mechanical cycling tests were performed with the samples immersed in distilled water at 37°C, with 100N load, frequency of 2Hz and 200.000 cycles. After the thermomechanical tests, the specimens were subjected to tensile tests in a universal testing machine EMIC DL 2000. The bond strength values were supplied by the computer of the testing machine, and obtained in kilogram force (Kgf) individually for each specimen. The data obtained hair tensile test were submitted when ANOVA test, with significance level of 5 %. Previous conducting this test, the were data are checked for normality and homocedasticity those testicles - Wilk Shapiro and Bartlett, respectivamente. By means of hum stereomicroscope has been found that the adhesive cementation failure mode to type, resin cement and surface zirconia occurred in all the evidence of bodies. It is concluded that the three types of resin cements tested in this study behaved way efficient cementation of two parts of hybrid pillars of zirconia.
104

Avaliação do destorque do parafuso protético de diferentes tipos de conexões com coroas longas

Rocha, Elissa Almeida 26 August 2014 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-06-26T12:34:48Z No. of bitstreams: 1 elissaalmeidarocha.pdf: 1048455 bytes, checksum: 482abe6dc9b27c43e6590f8c48ec4789 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-08-07T20:35:48Z (GMT) No. of bitstreams: 1 elissaalmeidarocha.pdf: 1048455 bytes, checksum: 482abe6dc9b27c43e6590f8c48ec4789 (MD5) / Made available in DSpace on 2017-08-07T20:35:48Z (GMT). No. of bitstreams: 1 elissaalmeidarocha.pdf: 1048455 bytes, checksum: 482abe6dc9b27c43e6590f8c48ec4789 (MD5) Previous issue date: 2014-08-26 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo deste estudo foi avaliar a influência de diferentes conexões no destorque do parafuso Neotorque sobre implantes com proporção coroa - implante (2:1), estudo in vitro, após ciclagem mecânica. Trinta implantes de 9 mm x 3,75 mm (Neodent®-Curitiba, Paraná, Brasil) foram utlizados, sendo 10 de cada tipo de conexão (CM,HE, HI) com seus respectivos munhões universais: (CM) ( 3,3/6/3,5), HE e HI ( 4,5,6,3) (Neodent®-Curitiba, Paraná, Brasil). Os implantes foram inseridos individualmente em resina acrílica (JET, Clássico, São Paulo, Brasil) com auxílio de um cilindro calcinável padronizado ( 2,5x1,5). O torque nos parafusos foi feito com torquímetro digital (Lutron TQ – 680, Impac, São Paulo), o grupo HE recebeu 30 N.cm, o grupo CM 15 N.cm e o grupo HI 20N.cm. Posteriormente a aplicação do torque, as coroas foram posicionadas sobre os pilares protéticos com vaselina sólida (Farmax, Divinópolis, Brasil) e em seguida foram submetidos à ciclagem mecânica (Simulador de Fadiga Mecânica, ERIOS, modelo ER – 11000), com aplicação de uma carga de 120N, 75 ciclos/s por 1.000.000 ciclos a 1 Hz, submersos em água destilada. Por fim, o destorque foi mensurado com o auxílio de um torquímetro digital (Lutron TQ-680, Impac, São Paulo/SP). Os valores de média de destorque (desvio padrão) obtidos após ciclagem mecânica foram: CM - 13,4 (1,83) N.cm, HI – 17 (1,69) N.cm e HE – 25,6 (1,95) N.cm. O teste de ANOVA (p<0,05) mostrou que não houve diferença estatisticamente significante entre os grupos (p=0,526) com relação aos diferentes tipos de conexão pilar - implante e a proporção coroa (2) – implante (1) após ciclagem mecânica. Para avaliar cada grupo independentemente em relação a perda de carga do torque de fechamento após ciclagem mecânica, foi realizada o teste t de student independente (p<0,05), obteve-se resultado estatisticamente significante para perda de torque inicial dentro de cada grupo: CM (0,022), HI (0,00) e HE (0,00). Concluiu-se que o tipo de conexão pilar - implante e da proporção coroa – implante (2:1) não influenciou na perda de torque após a ciclagem mecânica; a ciclagem mecânica influenciou na perda de torque dentro de cada grupo de conexão pilar – implante. / The aim of this study was to evaluate the influence of different connections in detorque Neotorque screw implant with crown ratio - implant (2:1), in vitro study, after mechanical cycling. Thirty of 9 mm x 3.75 mm (Neodent®-Curitiba, Paraná, Brazil) were utlizados implants, 10 of each connection type (CM, HE, HI) with their universal posts: (CM) ( 3, 3/6 / 3,5), HE and HI ( 4,5,6,3) (Neodent®-Curitiba, Paraná, Brazil). The implants were inserted individually in acrylic resin (JET, Classic, São Paulo, Brazil) using a standardized burn-cylinder ( 2,5x1,5). The torque on the bolts was done with digital torque meter (Lutron TQ - 680, Impac, São Paulo), the HE group received 30 N.cm, the CM group and 15 N.cm the HI group 20N.cm. Subsequently the application of torque, the crowns were placed on the abutments with petrolatum (Farmax, Divinópolis, Brazil) and then were subjected to mechanical cycling (Simulator Mechanical Stress, Erios, ER Model - 11000), with application of a 120N load, 75 cycles / sec per 1 million cycles at 1 Hz, immersed in distilled water. Finally, the detorque was measured with the aid of a digital torque meter (Lutron TQ-680, Impac, São Paulo / SP). The (standard deviation) values of average detorque obtained after mechanical cycling were: CM - 13.4 (1.83) N.cm, HI - 17 (1.69) and HE N.cm - 25.6 (1, 95) N.cm. The ANOVA test (p <0.05) showed no statistically significant difference between groups (p = 0.526) with respect to different types of abutment connection - implant and the crown ratio (2) - implant (1) after cycling mechanics. To evaluate whether each group compared to the pressure drop in torque after mechanical closure cycling, independent Student t (p <0.05) was performed, there was a statistically significant result for loss of initial torque in each group : CM (0.022), HI (0.00) and HE (0.00). It was concluded that the type of abutment connection - implant and crown ratio - implant (2: 1) no effect on the loss of torque after mechanical cycling; mechanical cycling effect on the loss of torque within each group of connection pillar - implant.
105

Nové trendy v ukládání RaO / New trends of disposal of radioactive waste

Vohralík, Lukáš January 2010 (has links)
The main point of my diploma thesis is accession the questions of disposal of radioactice waste and related proceeding with it. The thesis is engaged in estimation of the current disposal site in the Czech republic and analysis of the particular technological ways of the procces with radioactice waste.The thesis is engaged in real possibilities of maximum minimization radioactive waste in the Czech republic in the context of raising quantity radioactive waste. It is taken up new trends in disposal of radioactice waste and technology of the modification of radioactice waste before storing.
106

Influência do tratamento de superfície em diferentes substratos na resistência de união à cimento resinoso autoadesivo /

Almeida, Cláudia Cristina Miranda de Souza. January 2019 (has links)
Orientador: Paula Carolina Komori de Carvalho / Coorientador: Rodrigo Othávio de Assunção e Souza / Banca: Carolina Machado Martinelli Lobo / Banca: Eduardo Miyashita / Resumo: As reabilitações orais com próteses fixas na Odontologia passaram por grande evolução ao serem estabelecidos e firmados os conceitos de adesão química. A alta demanda estética desses tratamentos faz com que as cerâmicas que são materiais altamente biocompatíveis e com ótimas propriedades mecânicas, sejam amplamente utilizadas nas reabilitações orais. Nas próteses sobre implantes, o processo de cimentação de restaurações cerâmicas acontece sobre conexões metálicas em titânio (Ti), cobalto-cromo (CoCr) ou infra-estruturas personalizadas em zircônia (Zr). O processo de cimentação necessita de algumas etapas para promover o tratamento de superfície das restaurações indiretas e variam de acordo com a especificidade de cada substrato. O objetivo deste estudo foi avaliar a influência do tratamento de superfície em diferentes substratos de conexões protéticas utilizando primer e sistema adesivo universal contento o monômero funcional 10-MDP na resistência de união à cimento resinoso autoadesivo, por meio de teste mecânico de cisalhamento. Foram confeccionadas 120 amostras (n= 40 de Ti, CoCr e Zr) as quais foram incluidas em blocos de resina acrílica. As amostras foram subdivididas em 12 grupos (n=10), 3 grupos representam o controle e não tiveram a superfície tratada, os demais grupos tiveram a superfície tratada com primer monocomponente ou sistema adesivo universal contendo 10-MDP. Em seguida foi confeccionado um cilíndro de cimento resinoso (2mm de altura X 2,37mm de diâmetro) com... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Oral rehabilitations with fixed prostheses in Dentistry had grown with great evolution when the concepts of chemical adhesion were established and signed. The high aesthetic demand of these treatments makes Ceramics, that are highly biocompatible materials and with good mechanical properties, widely used in oral rehabilitation. In implant prostheses, the process of cementation happens between ceramic restorations on metallic connections in titanium (Ti) and / or cobalt chromium (CoCr) or custom zirconia (Zr) infrastructures. During the cementing process of ceramic restorations some surface treatment steps are required, these steps varying according to the type of specific ceramics. The aim of this study was to evaluate the influence of surface treatment on different substrates of prosthetic connections using primer and universal adhesive system containing 10-MDP functional monomer on bond strength to self-adhesive resin cement by mechanical shear test. One hundred and twenty samples (n = 40 Ti, CoCr and Zr) were made and included in blocks of acrylic resin. The samples were subdivided into 12 groups (n = 10), 3 groups represent the control and did not have the surface treated, the other groups had the surface treated with single component primer or universal adhesive system containing 10-MDP. Then a resin cement cylinder (2mm height X 2,37mm diameter) was made with the aid of a teflon device to measure the exact dimensions. Twenty four hours after the cylinders were made, the... (Complete abstract click electronic access below) / Mestre
107

Deposition Kinetics of Titanium and Zirconium Diffusion Coatings on Nickel Microwires via Pack Cementation

Achuthankutty, Ajith 16 June 2020 (has links)
No description available.
108

Development of Porous Metal-supported Solid Oxide Fuel Cells

Ren, Meng 10 1900 (has links)
<p>The introduction of metal supported cells may be a key innovation in the development of solid oxide fuel cell (SOFC) technology. The objective of this study was to develop a process of co-firing the ceramic layers of a solid oxide fuel cell attached to their porous metal support. This is a major departure from the traditional fuel cell architecture where the support layer is a ceramic composite made of YSZ and NiO.</p> <p>The problems to be eliminated during the fabrication process include the warping, cracking and delamination of the cell during the co-sintering process.</p> <p>In this study, the porous metal layer was produced by the freeze tape casting process. During co-sintering, it is necessary to match the relative shrinkage between the metal and ceramic layers. Different parameters which can influence the relative shrinkage were explored, including the heating rate, sintering temperature, sintering time, cell thickness, solid loading of the green tapes, applications of wet and dry hydrogen in the sintering atmosphere, as well as a change of the electrolyte material. Specifically, GDC was tested as an alternative electrolyte to YSZ.</p> <p>Since the porous metal substrate is exposed to air during fuel cell operation, it must be protected from oxidation. Therefore, the pack cementation method was used to apply a layer of aluminum onto the metal substrate. Variables such as temperature and exposure time of the coating materials were investigated in this thesis.</p> / Master of Applied Science (MASc)
109

Avaliação da resistência ao cisalhamento da zircônia após diferentes tratamentos de superfície / Evaluation of shear bond strength of zirconia after different surface treatments

Santos, Livia Aguiar 06 May 2011 (has links)
Cerâmicas de alto conteúdo cristalino, como a zircônia policristalina tetragonal estabilizada por ítrio (Y-TZP), apresentam ótimas propriedades mecânicas quando comparadas às cerâmicas convencionais, sendo cada vez mais empregadas como materiais restauradores indiretos. Entretanto, seu sucesso também depende da formação de uma união confiável com os agentes de cimentação. Porém, o aumento do conteúdo cristalino modificou as características de adesão entre cerâmica e cimento resinoso, não existindo um protocolo de cimentação bem estabelecido na literatura. Portanto, este estudo teve como objetivo avaliar o efeito na resistência ao cisalhamento de diferentes tratamentos de superfície sobre a zircônia, utilizando dois cimentos resinosos, assim como avaliar as possíveis diferenças no modo das fraturas. Cento e vinte amostras retangulares de zircônia foram incluídas em resina acrílica e divididas em 12 grupos (n=10), de acordo com os tratamentos de superfície e os cimentos (Panavia F e Rely X U100). Para cada cimento, os grupos experimentais foram formados da seguinte maneira: RU e Pa - controle (sem nenhum tratamento de superfície); ApRU e ApPa (aplicação do Alloy Primer); MzRU e MzPa (aplicação do Metal/Zircônia Primer); JatRU e JatPa (jateamento com partículas de óxido de alumínio de 50µm); JatApRU e JatApPa (jateamento e aplicação de Alloy Primer); JatMzRU e JatMzPa (jateamento e aplicação do Metal/Zircônia Primer). Os corpos de prova foram armazenados em água destilada à temperatura de 37°C por 24 horas, antes do teste de cisalhamento em uma máquina de ensaio universal (EMIC). Os valores foram submetidos primeiro a ANOVA a um critério (resistência ao cisalhamento) e teste de Tukey (p 0,05), independente do tratamento e do sistema de cimentação. Em seguida, ANOVA a dois critérios (tratamento de superfície e sistema de cimentação) e o teste de Tukey foram aplicados para observar com maior precisão a interação entre cimento e tratamento de superfície. Os resultados apresentados foram: RU - 11,71a, ApRU - 21,49b,e, MzRU - 30,38c,d, JatRU - 34,40c, JatApRU - 30,66c,d, JatMzRU - 38,06c, Pa - 11,35a, ApPa - 11,98a, MzPa - 11,46a, JatPa - 33,50c, JatApPa - 23,14b,d,e, JatMzPa - 18,66a,e. Por meio dos resultados obtidos foi possível concluir que a resistência ao cisalhamento pode ser melhorada ao utilizar o jateamento com partículas de óxido de alumínio e, para o RelyX U100, somente a aplicação do Metal/Zircônia Primer resultou em valores de adesão comparavéis ao tratamento mecânico. O cimento RelyX U100 apresentou maior resistência de união quando comparado ao Panavia F. / High crystalline content ceramics, such as yttria stabilized tetragonal zirconia polycrystal (Y-TZP), show great mechanical properties when compared to conventional ceramics, being increasingly used as indirect restorative materials. However, its success also depends on the reliable bond formation with luting agents. Though, the high crystalline content modified the adhesiveness between ceramic and resin cement although there isnt any cementing protocol established in literature. Therefore, the purpose of this study was to evaluate the effect of the shear bond strength after different surface treatments on the zirconia, using two resin cements and to evaluate possible differences in fracture modes. One hundred and twenty rectangular samples of zirconia were embedded in acrylic resin and divided into 12 groups (n=10) according to the surface treatments and the cements (Panavia F and RelyX U100). For each cement, the experimental groups were formed as follow: RU and Pa - control (no surface treatment); ApRU and ApPa (application of Alloy Primer); MzRU e MzPa (application of Metal/Zirconia Primer); JatRU and JatPa (air abrasion with 50µm Al2O3 particles); JatApRU and JatApPa (air abrasion and application of Alloy Primer); JatMzRU and JatMzPa (air abrasion and application of Metal/Zirconia Primer). The specimens were stored in distilled water at 37°C for 24 hours prior to the shear bond strength test in a universal testing machine (EMIC). The data were first analyzed by one-way ANOVA (shear bond strength) and Tukey test (p<0.05), regardless of the treatment and the luting system. Then two-way ANOVA (surface treatment and luting system) and the Tukey test were applied in order to observe more accurately the interaction between cement and surface treatments.The results presented were: RU 11.71a, ApRU 21.49b,e, MzRU 30.38c,d, JatRU 34.40c, JatApRU 30.66c,d, JatMzRU 38.06c, Pa 11.35a, ApPa 11.98a, MzPa 11.46a, JatPa 33.50c, JatApPa 23.14b,d,e, JatMzPa 18.66a,e. Based on the results obtained, it was possible to conclude that the shear bond strength can be improved when air abrasion was used with aluminum-oxide particles and for the RelyX U100, only the application of Metal / Zirconia Primer resulted in adhesion values comparable to mechanical treatment. The RelyX U100 cement showed higher bond strength when compared to Panavia F.
110

Comparação entre cimentos resinosos e uma resina \"bulk fill\" na cimentação de pinos de fibra de vidro - Análise de resistência adesiva e dureza / Comparison between resin cements and a \"bulk fill\" resin composite on the luting of fiberglass- reinforced posts cementation - Bond strength and hardness analysis

Lobo, Tamile Rocha da Silva 29 January 2018 (has links)
Este estudo comparou a performance de quarto agentes cimentantes com diferentes estratégias adesivas para cimentação de pinos de fibra de vidro em canais radiculares, através do teste de resistência adesiva e avaliando a dureza em diferentes profundidades. Para isto, foram utilizadas 60 raízes bovinas tratadas endodonticamente. Foram cimentados pinos de fibra de vidro Rebilda Post 20 de acordo com os seguintes protocolos divididos nos seguintes grupos: Grupos QM: Adesivo autocondicionante dual Futurabond DC + cimento resinoso dual Bifix QM; Group SE: Cimento resinoso autocondicionante de polimerização dual Bifix SE; Group RB: Adesivo autocondicionante de polimerização dual Futurabond DC + Resina Rebilda; Group XB: aplicação do adesivo autocondicionante de polimerização dual Futurabond DC + resina composta do tipo \"bulk fill\" X-tra Base. As raízes foram cortadas em fatias de 1mm e separadas em terços, sendo obtidos 2 corpos de prova por terço. Foram avaliadas a resistência adesiva (n=10) e a microdureza (n=5), após uma semana e após 4 meses de armazenamento em água. Para o teste de resistência adesiva (push- out) uma fatia de cada terço foi testada depois de uma semana e as outras 3 fatias provenientes do mesmo dente avaliadas após 4 meses. O ensaio de push out foi realizado a uma velocidade de 0,5mm/min até o deslocamento do pino e/ou fratura da interface adesiva. Para o teste de microdureza 20 dentes foram selecionados aleatoriamente e de cada dente foram obtidas seis 6 fatias que foram armazenadas em água destilada por uma semana até a mensuração em microdurômetro, após uma semana e após 4 meses. Os corpos de prova foram submetidos ao teste de microdureza Knoop em microdurômetro HMV-2000 (Shimadzu, Tokyo, Japan), cinco endentações foram realizadas na camada de cimento de cada fatia. Os dados referentes aos testes de resistência adesiva (push- out) e microdureza foram submetidas análise de variância 3 fatores (ANOVA), teste de tukey (p<0,05) e teste de correlação de Person. Os valores de resistência adesiva não apresentaram diferenças estatísticas significantes quando observado os valores de resistência adesiva entre os grupos QM, RB e XB (p>=0.05), porém menores valores de resistência adesiva foram observados no Grupo SE. Quando considerada a variável envelhecimento não foram encontradas diferenças na resistência adesiva medida em uma semana e 4 meses (p>=0.05). Para a microdureza diferenças estatisticamente significantes foram encontradas nos diferentes terços da raiz (p<0.05). Os agentes cimentantes apresentaram diferenças estatísticas significantes na dureza (p<0.05). O grupo XB apresentou os maiores valores seguido por QM, RB e SE. Os grupos SE, RB e XB não apresentaram 80% da dureza máxima nas fatias correspondentes a região apical do canal radicular. O teste de Person mostrou haver correlação positiva linear entre a resistência adesiva e a dureza medidas antes e após o envelhecimento. O uso cimento resinoso dual, associado a uma aplicação anterior do sistema adesivo, ainda é a escolha mais segura, pois apresentou valores de força de adesão elevados, associados a valores de dureza adequados, mesmo em regiões apicais do canal radicular. / This study compared the performance of four cementitious agents with different adhesive strategies for cementing fiberglass pins in root canals, through the adhesive strength test and evaluating the hardness at different depths. For this, 60 endodontically treated bovine roots were used. Rebilda Post 20 fiberglass pins were cemented according to the following protocols divided into the following groups: QM groups: dual self-etching adhesive Futurabond DC + resin cement Bifix QM; Group SE: Dual polymerization resin cement Bifix SE; Group RB: application of self-etching dual-polymerization adhesive Futurabond DC + resin Rebilda; Group XB: application of the self-etching adhesive for dual polymerization Futurabond DC + composite resin of the bulk fill type X-tra Base. The roots were cut into 1mm slices and separated into thirds, obtaining 2 specimens per third. Bond strength (n =10) and microhardness (n = 5) were evaluated after one week and after 4 months of storage in water. For the push-out test one slice of each third was tested after one week and the other 3 slices from the same tooth evaluated after 4 months. The push out test was performed at a speed of 0.5mm / min until the pin displacement and / or fracture of the adhesive interface. For the microtensile test, 20 teeth were randomly selected and six slices were obtained from each tooth, which were stored in distilled water for one week until microdurometer measurement, after one week and after four months. The specimens were submitted to the Knoop microhardness test in HMV-2000 microdurometer (Shimadzu, Tokyo, Japan), five indentations were performed in the cement layer of each slice. The data for the tests of bond strenght (push-out) and microhardness were submitted to analysis of variance 3 factors (ANOVA) and Tukey test (p <0.05) and Person correlation test. The bond strength values did not present significant statistical differences when the adhesive strength values were observed between the groups QM, RB and XB (p>=0.05), but lower values of adhesive strength were observed in the SE Group. When the aging variable was considered, differences in adhesive strength measured at one week and 4 months (p>=0.05) were not found. For microhardness, statistically significant differences were found in the different thirds of the root (p <0.05). The cementing agents presented significant statistical differences in the hardness (p <0.05). The XB group presented the highest values followed by QM, RB and SE. The groups SE, RB and XB did not present 80% of the maximum hardness in the slices corresponding to the apical region of the root canal. The Person test showed a linear positive correlation between the adhesive strength and the hardness measured before and after aging. The use of dual resin cement, combined with a previous application of the adhesive system, is still the safest choice, since it presented high values of bond strength, associated with adequate hardness values, even in apical regions of the root canal.

Page generated in 0.0891 seconds