Spelling suggestions: "subject:"centrifuging"" "subject:"centrifuge""
1 |
Effekt av ändrade centrifugeringsparametrar på rutinkemi- och koagulationsanalyser / The effect of altered centrifugation parameters on routine chemistry and coagulation assaysTuran, Muhammed January 2022 (has links)
To separate plasma/serum from blood cells, blood samples are centrifuged. Currently, there is no standard centrifugation protocol available. However, there are several centrifugation recommendations from the tube manufacturers. The aim of this study is to evaluate centrifugation program with a shorter centrifugation time and higher centrifugal force and how it affects measured analyte concentrations. 120 sample pairs were collected in lithium-heparin tubes and sodium citrate tubes from 120 participants. One sample of each pair was then centrifuged with reference program (2000g, 10min) for routine chemistry samples and (2500g, 15min) for coagulation samples. The other sample of each pair was centrifuged with programs (3000g, 7min). The statistical analysis was performed using the Student’s t-test and the Holm-Bonferroni method. P-value less than 0.05 was considered statistically significant.There was no significant difference between data from BD tubes and Greiner tubes, therefore the corresponding data from both groups were merged. No statistically significant difference was observed for the following parameters; Cobalamin (B12), High-density lipoprotein (HDL), Lactate dehydrogenase (LD), Phosphate, Triglycerides (TG), Thyroid stimulating hormone (TSH), Activated partial thromboplastin time (APTT), Fibrinogen (Fib) and Prothrombin complex PK (INRR). However, the statistical analysis showed a significant difference regarding potassium (K). Centrifugation program (3000g, 7min) can replace the programs (2000g, 10min) and (2500g, 15min) which are recommended by the tube manufacturers BD & Greiner, with the exception of Potassium which requires more research. A trace of increasing hemolysis, still within acceptable limits, was detected in samples centrifuged with programs (3000g, 7min). The centrifugation programs with a shorter time or less acceleration is preferred. / Blodprover centrifugeras för att separera plasma/serum från blodceller. Inget standardprotokoll för centrifugering är tillgänglig dock finns flertal centrifugeringsrekommendationer från rörtillverkarna. Syftet med denna studie är att utvärdera centrifugeringsprogram med en kortare centrifugeringstid och högre g-tal, samt hur det påverkar uppmätta analytkoncentrationer. 120 provpar samlades i litium-heparin-rör respektive natrium-citrat-rör från 120 deltagare. Det ena provet av varje provpar centrifugerades med referensprogram (2000g, 10 min) för rutinkemi respektive (2500g, 15min) för koagulation medan det andra centrifugerades med program (3000g, 7min). Statistiska analysen utfördes med hjälp av Student t-test och Holm-Bonferroni metoden. P-värde mindre än 0,05 ansåg vara statistiskt signifikant. Ingen betydande skillnad fanns mellan data från BD-rör och Greiner-rör, därför har motsvarande data från både gruppen slagits ihop. Ingen statistiskt signifikant skillnad observerades för följande undersökta parametrar; Kobalamin (B12), High-density lipoprotein (HDL), Laktatdehydrogenas (LD), Fosfat, Triglycerider (TG), Tyroideastimulerande hormon (TSH), Aktiverad partiell tromboplastintid (APTT), Fibrinogin (Fib) och Protrombinkomplex PK(INR). Däremot visade den statistiska analysen en signifikant skillnad avseende kalium (K). Centrifugeringsprogram (3000g, 7min) kan ersätta programmen (2000g, 10min) och (2500g, 15min) som rekommenderas av rörtillverkarna BD & Greiner, med undantag av Kalium som kräver mer undersökning. Ett spår av ökande hemolys, dock fortfarande inom acceptabla gränser, upptäcktes i prover centrifugerades med program (3000g, 7min). Därpå är centrifugeringsprogram med kortare tid eller mindre hastighet att föredra.
|
2 |
Metod för provtagning av svartlut och analys av såpa i svartlut / Method for sampling black liquor and analysis of soap in black liquorHjalmarson, Inger-Johanne January 2019 (has links)
In paper pulp production, many details can be optimized. For optimal separation of soap from black liquor, it is important to know the amount of soap in the black liquor. A project to produce a method for sampling black liquor and a method for measuring how much soap is present in black liquor by centrifugation was done at Södra Cell Mönsterås. Through centrifugation faster analysis can be done. It took a long time to develop a satisfactory sampling method, but with the help of careful checking of temperature and time, a method was achieved that worked at temperatures between 90 and 100°C, which were the temperatures that were most frequently found, but are higher than the optimum temperature for soap separation. The black liquor turned out to be inhomogeneous, so the project failed to obtain an optimal analysis method within the framework of this project. In the experiment, the centrifuge settings were optimized to 87°C, 2500 rpm and 10 minutes Further attempts could provide more optimal settings for the centrifuge and a substitute for black liquor could make a validation of the centrifuge possible. / Pappersmassaproduktion är komplex, och en rad faktorer kan optimeras. En viktig parameter vid såpavskiljning är innehållet såpa i svartlut eftersom en värdefull produkt, tallolja utvinns av såpa. Projektet syftar till att ta fram en metod för provtagning av svartlut och en metod för att mäta halten såpa i svartluten genom centrifugering. Genom centrifugering kan snabbare analyser göras. Arbetet har utförts på Södra Cell Mönsterås. Arbetet att utveckla en tillfredsställande provtagningsmetod var komplicerad, men med hjälp av noggrann koll på temperatur och tid uppnåddes en metod som fungerade vid temperaturer mellan 90 och 100°C, vilket var de temperaturer som oftast fanns, men som är högre än optimal temperatur för såpavskiljning. Svartluten visade sig vara inhomogen, därför lyckades det inte att få fram en optimal analysmetod inom ramen av detta projekt. I försöket optimerades centrifugens inställningar till 87°C, 2500 rpm (varv per minut) och 10 minuter. Vidare försök skulle kunna ge mer optimala inställningar för centrifugen genom den utvecklade prov, och ett substitut för svartlut skulle kunne göra en validering av centrifugen möjlig.
|
3 |
Preanalytiska faktorer och dess påverkan på levermarkörerna ALAT, ASAT och bilirubin : En allmän litteraturstudie / Preanalytical factors and their effect on the liver markers ALAT, ASAT and bilirubin : A literature reviewErlandsson, Kristin, Klasson, Evelina January 2020 (has links)
Preanalytiska faktorer såsom provhantering och förvaring utgör den vanligaste felkällan inom laboratoriemedicin, vilket tyder på bristande kunskap kring faktorer som påverkar provers stabilitet. ALAT, ASAT och bilirubin är markörer för utvärdering och behandling inom leverdiagnostik, varpå tillförlitliga provsvar är av stor vikt.Syfte: Att granska tidigare studier och göra en sammanställning av stabiliteten för ALAT, ASAT och bilirubin vid olika typer av förvaring innan och efter centrifugering, olika centrifuginställningar, samt i rör med olika tillsatser.Metod: En allmän litteraturstudie gjordes genom systematisk sökning och bearbetning av vetenskapliga artiklar relaterade till syftet.Resultat: Studierna om analytstabilitet hos centrifugerade prover hade en stor spridning mellan resultaten som kan förklaras av studiernas olika upplägg, främst med tanke på att de pågick under olika lång tid. Gällande jämförelse av provrör skiljde det som mest fem dagar mellan PST och Barricor-rör i en av studierna. Studierna om centrifugering visade inte på någon skillnad i stabilitet med de inställningar av centrifugalkraft och tid som användes.Slutsats: Bristen på studier med liknande studiedesign gör det svårt att dra några säkra slutsatser kring stabiliteten vid olika förvaring. Resultatet antyder att varken olika rörtillsatser, centrifuginställningar eller fördröjd centrifugering upp till 24 timmar påverkar stabiliteten för ALAT, ASAT eller bilirubin. / Preanalytical factors such as specimen handling are the most common source of error in laboratory medicine, suggesting a lack of knowledge about factors affecting sample stability. ALAT, ASAT and bilirubin are markers that underlie evaluation and treatment in liver diagnostics, therefore reliable test answers are of great importance.Objective: To review previous studies and compile the stability of ALAT, ASAT and bilirubin for different storage before and after centrifugation, different centrifuge settings, and in tubes with different additives.Method: A literature review was done through systematic search and processing of scientific articles related to the objective.Results: The studies on analyte stability of centrifuged samples showed great variance between the results, mainly due to the studies lasting for different lengths of time. One study comparing test tubes showed a five day difference for ASAT between PST and Barricor tubes. Centrifugation studies showed no difference in stability with the centrifugal settings used.Conclusion: The lack of studies with similar study designs makes it difficult to draw any certain conclusions about the stability in different storage conditions. The result suggests that neither different tube additives, centrifuge settings nor delayed centrifugation up to 24 hours affect the stability of ALAT, ASAT or bilirubin.
|
4 |
Dewatering Cellulose Nanofibril Suspensions through Centrifugation / Avvattning av cellulosananofibriller genom centrifugeringAstorsdotter, Jennifer January 2017 (has links)
Cellulose nanofibrils (CNF) is a renewable material with unique strength properties. A difficulty in CNF production is that CNF suspensions contain large amounts of water. If CNF suspension volume can be decreased by dewatering facilitated by centrifugation, then transportation costs and storage costs can be reduced. The aim of this thesis is to investigate the impact various parameters have on CNF centrifugation dewatering and identify optimal conditions for maximal water removal. A laboratory study was conducted using four materials; 2.0 w% enzymatically treated CNF (CNF1), 1.9 w% carboxymethylated CNF (CNF2) and two commercial samples (1.9 w% CNFA and 1.8 w% CNFB). The main method was analytical centrifugation up to 2330 g. Parameters tested were initial concentration before centrifugation, temperature, NaCl addition, pH, and applied solid compressive pressure (g-force and surface weight). In addition to centrifugation experiments the four materials were characterized with laser diffraction, UV-vis absorption, Dynamic light scattering, and dry weight measurements. Analysis of the experimental data collected show that increase in initial concentration give a higher final concentration, but less water is removed. Furthermore, temperature changes have no effect on separation of CNF and water. At an applied solid compressive pressure of 3 kPa and initial concentration at 1.5 w% the concentrations 5.5 w%, 1.5 w%, 4.0 w%, and 4.3 w% can be reach for CNF1, CNF2, CNFA, and CNFB respectively. After extrapolation of polynomial functions fitted to experimental data an applied solid compressive pressure of 22 kPa and initial concentration at 1:5 w%, the concentrations 9.1 w%, 1.5 w%, 6.9 w%, and 7.9 w% are predicted for CNF1, CNF2, CNFA, and CNFB respectively. The thickening of CNF suspensions achieved and predicted in this thesis implies possibilities for large amounts of water removal, e.g. the water content in a CNF1 suspension is reduced from 65.7 litres/kg CNF to 10.0 litres/kg CNF at the solid compressive pressure 22 kPa. The concentrations at 22 kPa are determined by extrapolation from experimental data <3 kPa solid compressive pressure. The carboxymethylated CNF2 can not be dewatered unless it is diluted or if salt or pH is adjusted. This is directly correlated to the electrostatic forces in the suspension and the Debye length. Addition of salt or lowered pH also eliminate any concentration gradients in diluted and centrifuged CNF2 suspensions. / Cellulosa nanofibriller (CNF) är ett förnybart material med unika styrkeegenskaper. En svårighet med produktion av CNF är att CNF suspensioner innehåller stora mängder vatten. Om volymerna av CNF suspensioner kan minskas med avvattning genom centrifugering, då kan transport- och lagerkostnader sänkas. Målet med det här examensarbetet är att undersöka vilken inverkan olika parametrar har på CNF-avvattning genom centrifugering och identifiera optimala förhållanden för maximalt avlägsnande av vatten. En laboratoriestudie utfördes på fyra olika material. De fyra materialen är 2 w% enzymatiskt behandlad CNF (CNF1), 1.9 w% karboxymetylerad CNF (CNF2) och två kommersiella prover (1.9 w% CNFA och 1.8 w% CNFB). Den huvudsakliga metoden var analytisk centrifugering upp till maximalt 2330 g. De testade parametrarna var initial koncentration innan centrifugering, temperatur, NaCl tillsats, pH, och applicerat fast kompressionstryck (g-kraft och ytvikt). Förutom centrifugeringsexperimenten så karaktäriserades the fyra mmaterialen med laser diffraktion, UV-vis absorption, dynamisk ljusspridning och vägningar av torrhalt. Analys av den experimentella data som insamlats visar att en ökad initial koncentration ger en högre slutkoncnentration, men mindre vatten kan bortföras. Temperaturförändringar har ingen effekt på separation av CNF och vatten. Vid ett applicerat fast kompressibelt tryck på 3 kPa och en initial koncentration 1.5 w% kan koncentrationerna 5.5 w%, 1.5 w%, 4.0 w%, och 4.3 w% nås för CNF1, CNF2, CNFA, och CNFB. Efter extrapolering av polynoma funktioner passad till experimentell data förutspås att koncentrationerna 9.1 w%, 1.5 w%, 6.9 w%, och 7.9 w% kan nås för CNF1, CNF2, CNFA, and CNFB vid 22 kPa och en initial koncentration på 1.5 w%. Förtjockningen av CNF suspensioner som kan, eller förutspås kunna nås genom centrifugering i det här examensarbetet innebär att det är möjligt att avlägsna stora mängder vatten, till exempel kan vatteninnehållet i CNF1 minskas från 65.7 liter/kg CNF till 10.0 liter/kg CNF vid 22 kPa fast kompressionstryck. Koncentrationerna vid 22 kPa fast kompressionstryck är extrapolerade från exprimentell data <3 kPa fast kompressionstryck. Den karboy- metylerade CNF2 kan inte avvattnas om den inte späds ut eller om salt eller pH justeras. Detta är direkt kopplat till de elektrostatiska krafterna i suspensionen och Debye längden. Tillsats av salt eller sänkt pH eliminerar också de koncentrationsgradienter som kan förekomma i utspädda centrifugerade CNF2 suspensioner.
|
5 |
Low-concentration Bacteria Separation from Whole Blood through a Slanted Filter in a Centrifuge TubeZeng, Kaiyang January 2023 (has links)
Sepsis characterized by severe bloodstream bacterial infection that results in high mortality rates and medical expenses has become a global healthcare challenge. The current clinical sepsis diagnosis is based on blood culture and requires a long waiting time, delaying effective treatments. The emerging sepsis diagnosis shortens the turn-around of time but requires an efficient bacteria separation from the blood beforehand. In this master’s degree project, a new filter-based method of separating bacteria from the blood is investigated to meet the clinical need for future sepsis diagnosis. The separation device is controlled within the size of a centrifuge falcon tube and integrated with a slanted filter inside. Through a centrifuge, blood cells and bacteria are maneuvered toward the filter and separated by it. Using the optimal design, at concentrations as low as 100 CFU/mL, the device can recover around 30% of bacteria of E. coli, K. pneumoniae, and S. aureus from 1 mL of whole blood within 60 minutes, and reject 99.4% RBCs from going through the filter. Bacteria recovery at 10 CFU/mL concentration demonstrated all-positive results, making this new separation method a promising candidate for future clinic needs in sepsis diagnosis. / Sepsis, som kännetecknas av svår bakterieinfektion i blodomloppet och leder till hög dödlighet och medicinska kostnader, har blivit en global utmaning inom hälso- och sjukvården. Den nuvarande kliniska diagnosen av sepsis baseras på blododling och kräver lång väntetid, vilket försenar effektiva behandlingar. Den framväxande diagnosmetoden för sepsis förkortar väntetiden men kräver effektiv separation av bakterier från blodet. I detta masterprojekt undersöks en ny filterbaserad metod för att separera bakterier från blodet för att möta den kliniska efterfrågan inom framtida sepsisdiagnostik. Separationsenheten kontrolleras inom storleken av en falcon-rör och är integrerad med en lutande filterinsats. Genom en centrifug manövreras blodceller och bakterier mot filtret och separeras av det. Genom att använda den optimala designen kan enheten återhämta cirka 30% av bakterierna E. coli, K. pneumoniae och S. aureus från 1 ml helblod med koncentrationer så låga som 100 CFU/ml inom 60 minuter, och avvisa 99,4% av de röda blodkropparna från att passera genom filtret. Återhämtningen av bakterier vid en koncentration av 10 CFU/ml visade helt positiva resultat, vilket gör denna nya separationsmetod till en lovande kandidat för framtida kliniska behov inom sepsisdiagnostik.
|