• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 130
  • 54
  • 34
  • 31
  • 22
  • 15
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 470
  • 143
  • 105
  • 74
  • 64
  • 63
  • 52
  • 49
  • 45
  • 34
  • 33
  • 32
  • 31
  • 29
  • 29
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
151

Caracterização e aplicação de duas câmaras de extrapolação em feixes padronizados de radiação X / Characterization and application of two extrapolation chambers in standard X radiation beams

SILVA, ERIC A.B. da 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:33:24Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:24Z (GMT). No. of bitstreams: 0 / As câmaras de extrapolação são câmaras de ionização com volume variável e são utilizadas principalmente como detectores de radiação beta. Neste trabalho foram caracterizadas duas câmaras de extrapolação, uma comercial da marca PTW, e uma outra desenvolvida no Laboratório de Calibração do IPEN, para aplicação como sistemas de referência em feixes de mamografia, radiodiagnóstico convencional e radioterapia. Os resultados obtidos nos testes de caracterização da resposta das câmaras de extrapolação: corrente de fuga, estabilidade de curto e médio prazos, determinação das correntes de saturação e das eficiências de coleção de íons, dependência angular e energética, mostram que estas câmaras de extrapolação podem ser utilizadas em dosimetria de feixes de radiação X de energias baixas. Os fatores de transmissão no tecido e os fatores de calibração foram também determinados para todas as qualidades de radiação citadas. Finalmente, foi estabelecido um procedimento de calibração de detectores de radiação em feixes padronizados de radiação X, utilizando as câmaras de extrapolação. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
152

Caracterizacao de sistemas tandem de camaras de ionizacao comerciais para dosimetria de feixes de raio X (nivel radioterapia)

GALHARDO, EDVALDO P. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:43:06Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:08:03Z (GMT). No. of bitstreams: 1 06118.pdf: 5177469 bytes, checksum: 1a0ed58fc3fd28df339dcde05cba57d4 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
153

Caracterização de uma câmara de ionização ar-livre em feixes diretos de raios X utilizados em mamografia / Characterization of a free-air ionization chamber in direct X-ray beams as used in mammography

LIMA, MATEUS H. de 21 January 2015 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2015-01-21T09:58:13Z No. of bitstreams: 0 / Made available in DSpace on 2015-01-21T09:58:13Z (GMT). No. of bitstreams: 0 / Neste trabalho foram realizados testes de estabilidade e de caracterização de uma câmara de ionização de ar-livre com cilindros concêntricos da marca Victoreen, modelo 481. Os testes foram feitos utilizando feixes diretos de mamografia como uma contribuição para a implantação desta câmara como sistema padrão primário para a grandeza kerma no ar. Os testes de caracterização realizados foram: curva de saturação, eficiência de coleção de íons, efeito de polaridade, linearidade da resposta com a taxa de kerma no ar e linearidade da resposta com a variação volumétrica. O teste de eficiência de coleção de íons possibilitou a determinação do fator de correção para recombinação iônica. A maioria dos testes realizados esteve em conformidade com os limites estabelecidos por normas internacionais. Foram obtidos os fatores de correção para atenuação de fótons no ar para as qualidades de mamografia com filtros de alumínio e molibdênio. Foram determinados também os fatores de correção para transmissão e espalhamento de fótons nas bordas do diafragma para as qualidades de mamografia com filtro de alumínio e para a qualidade padrão de mamografia com filtro de molibdênio. / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
154

"Intercomparação de câmaras de ionização em feixes padrões de Raios-X, níveis radioterapia, radiodiagnóstico e radioproteção" / INTERCOMPARISON OF IONIZATION CHAMBERS IN STANDARD X-RAY BEAMS, AT RADIOTHERAPY, DIAGNOSTIC RADIOLOGY AND RADIOPROTECTION LEVELS

Ana Carolina Moreira de Bessa 05 January 2007 (has links)
Tendo em vista a importância da calibração de instrumentos medidores de radiação e do conhecimento das principais características destes instrumentos, diversos tipos de câmaras de ionização foram intercomparados em termos de seus coeficientes de calibração e dependência energética, em feixes padrões de raios X, níveis radioterapia, radiodiagnóstico e radioproteção. Foi realizada uma intercomparação de activímetros utilizados em medicina nuclear, com três radionuclídeos: 67Ga, 201Tl e 99mTc. Todos os activímetros que participaram da intercomparação apresentaram resultados dentro dos limites recomendados pela norma CNEN-NE-3.05. Para completar o conjunto de qualidades de radiação do Laboratório de Calibração de Instrumentos do IPEN, foram estabelecidos feixes de radiação-X, nível radioproteção e radioterapia de energias baixas, seguindo recomendações internacionais. Três metodologias para a obtenção de coeficientes de calibração de câmaras de ionização não seladas em feixes de radiação-X foram estudadas e comparadas. Um conjunto de câmaras de ionização Victoreen, especialmente projetado para uso em intercomparações laboratoriais, foi submetido a testes de caracterização. O desempenho destas câmaras mostrou que elas podem ser utilizadas em feixes de radiação-X nível radioproteção de maneira segura, visto que nestes feixes estas câmaras apresentaram resultados em conformidade com recomendações internacionais. No entanto, seu uso em feixes de radioterapia e de radiodiagnóstico deve ser feito com algumas considerações, pois especialmente nos testes de dependência energética e de tempo de estabilização, estas câmaras não atenderam às respectivas recomendações internacionais. Este trabalho apresenta dados sobre o desempenho de diversos modelos de câmaras de ionização em diferentes feixes de radiação-X, fornecendo uma ferramenta para a escolha do instrumento mais adequado para a realização de medições em feixes de radiação ionizante / Since the calibration of radiation measurement instruments and the knowledge of their major characteristics are very important subjects, several different types of ionization chambers were intercompared in terms of their calibration coefficients and their energy dependence, in radiotherapy, diagnostic radiology and radioprotection standard beams. An intercomparison of radionuclide calibrators for nuclear medicine was performed, using three radionuclides: 67Ga, 201Tl and 99mTc; the results obtained were all within the requirements of the national standard CNEN-NE-3.05. In order to complete the range of radiation qualities of the Calibration Laboratory of IPEN, standard radiation beam qualities, radiation protection and low energy radiation therapy levels, were established, according international recommendations. Three methodologies for the calibration of unsealed ionization chambers in X-ray beams were studied and compared. A set of Victoreen ionization chambers, specially designed for use in laboratorial intercomparisons, was submitted to characterization tests. The performance of these Victoreen ionization chambers showed that they are suitable for use in radioprotection beams, because the results obtained agree with international recommendations. However, these Victoreen ionization chambers can be used in radiotherapy and diagnostic radiology beams only with some considerations, since their performance in these beams, especially in relation to the energy dependence and stabilization time tests, did not agree with the international recommendations for dosimeters used in radiotherapy and diagnostic radiology beams. This work presents data on the performance of several types of ionization chambers in different X-ray beams, that may be useful for choosing the appropriate instrument for measurements in ionizing radiation beams.
155

Reaction studies using bubble chambers

Bowman, Martin January 1964 (has links)
No description available.
156

An experimental study of some K-p interactions at 6 GeV/c

Wilkinson, K. I. January 1967 (has links)
No description available.
157

The study of elementary particle events using a computer-controlled system

Lawrence, D. E. January 1967 (has links)
No description available.
158

Their Lordships divided? : the representation of women in the transitional House of Lords 1999-2009

Eason, Christina January 2011 (has links)
This thesis set out to discern how women's representation, as a multi-faceted concept and process, plays out in the context of the House of Lords. The primary motivation of this inquiry concerned the reality that women are persistently under-represented in political chambers worldwide. Beyond this, scholarship has overlooked the site of the House of Lords despite significant advances made in women's presence that facilitate closer analysis. This is also compounded by the status of the chamber itself: in its 'transitional' phase post the passing of the House of Lords Act 1999 the chamber is suggested to act with greater legitimacy and effectiveness. Finally concentration upon the representation of women in the transitional House of Lords is pertinent as the chamber remains in a state of flux and there is an opportunity to prioritise women's representation as a key plank of the reform agenda. Normative feminist interpretations of representation are the primary frameworks of analysis. Methodologically, this research inquiry synthesised and triangulated the use of quantitative and qualitative research techniques in order to unpack the processes and influences upon all dimensions of women's political representation in the House of Lords. This helped to present a sufficiently nuanced analysis. There have been obvious attempts to numerically feminise the chamber, although there are systemic de facto and de jure reserved seats for men in the chamber which guard against radical improvements in women's descriptive presence. Women peers undertake important roles and the House of Lords maintains a culture and institutional norms that are befitting for women and feminised styles of politics which is positive for the symbolic representation of women. Finally, women peers actively seek to represent women through the agenda-setting features of the Lords, although the way this is manifested is mediated by political affiliation. The opportunities to substantively represent women through the legislative features of the House of Lords are narrower, although both male and female peers have successfully influenced legislative output to act for women.
159

Det var en gång... : En enkätstudie om högläsning och boksamtal på lågstadiet med kvalitativa och kvantitativa aspekter

Basualto, Sanna, Udén Möller, Erika January 2021 (has links)
Studien syftar till att synliggöra i vilken utsträckning och med vilka motiv boksamtal och högläsning av skönlitteratur sker på lågstadiet. Dessutom undersöks vilka faktorer som inverkar på hur F–3-lärare arbetar kring boksamtal och högläsning av skönlitteratur utifrån Aidan Chambers teori, Läsandets cirkel (2011).   Denna studie innefattar både kvalitativa och kvantitativa perspektiv och baseras på en digital enkät som delats via två lärargrupper på Facebook, under hösten 2021. Utifrån dessa enkätsvar har vi kunnat utläsa att majoriteten av respondenterna anser att högläsning är en mycket viktig aktivitet i klassrummet där högläsning är en del av den dagliga undervisningen. 80% av högläsningen syftar till att stimulera elevernas läsförståelse och visar således på högläsning som en aktivitet utifrån ett färdighetsperspektiv. Detta motsätter en samlad forskningsbild som visar på de många möjligheter som skönlitteratur kan främja utifrån litteraturens premisser, där en bredare världssyn och identitetsskapande är två viktiga aspekter. Även boksamtal anses vara en viktigt aktivitet hos respondenterna, dock har faktorer som brist på tid, stora- eller oroliga elevgrupper samt intresset hos både elever och lärare, en inverkan på undervisningen. Vi har kunnat utläsa att arbetet med högläsning och boksamtal har utvecklingsmöjligheter då vår studie visar att lärare i hög grad önskar ha mer boksamtal, söker struktur i sitt arbete med boksamtal och efterlyser mer tid för främst förberedelse samt inläsning av litteratur. Diskussionsavsnittet diskuterar samtliga resultat i förhållande till tidigare forskning, bakgrund samt studiens teoretiska utgångspunkt. Avslutningsvis belyser denna studie intressanta aspekter för vidare forskning med litteraturdidaktisk relevans.
160

Measuring Nitrogen Transformation in Wastewater Impacted Streams Using In-Situ Benthic Chambers

Beltran, Makenzi 01 May 2019 (has links)
Acrylic chambers and metal frames were installed at the sediment-water interface of streams impacted by the effluent from wastewater reclamation facilities in order to determine nitrogen rates for nitrification, denitrification, assimilation, ANAMMOX, and DNRA. Each chamber was dosed with an isotopic form of nitrate (15NO3 - ), and both isotopic (15N) and non-isotopic (14N) samples were collected. The project locations included East Canyon Creek near the East Canyon Wastewater Reclamation Facility in Park City, Utah and Box Elder Creek near the Brigham City Wastewater Treatment Plant in Brigham City, Utah. Separate chamber measurements were conducted upstream and downstream of each wastewater reclamation facility in order to determine the impact of the wastewater effluent on the stream. At the conclusion of the study, significant rates for both traditional (nitrification, denitrification, assimilation) and non-traditional nitrogen transformations (DNRA, ANAMMOX) were found at various locations. Specific transformations were found exclusively upstream or exclusively downstream of the wastewater treatment plant. Transformations that were found both upstream and downstream of the treatment plants were not significantly different, indicating no impact from the WWTPs on nitrogen transformations. Additionally, the use of isotopic nitrogen for the study did not prove necessary for determining nitrification and denitrification rates.

Page generated in 0.0502 seconds