251 |
Caracterização térmica, grau de conversão, resistência à flexão e dureza de compósitos comerciais tratados termicamente / Thermal characterization, degree of conversion, flexural strength and Knoop hardness of heat treated commercial compositesMiyazaki, Caroline Lumi 03 August 2010 (has links)
Visando otimizar as propriedades químicas e mecânicas de compósitos de uso direto aplicados na forma indireta, associados a tratamentos térmicos experimentais (TT), torna-se necessária uma caracterização térmica que permita a determinação de uma temperatura de TT segura (abaixo da temperatura de início de perda de massa). Assim, a primeira etapa deste estudo consistiu em caracterizar termicamente dez compósitos comerciais (Z100, Filtek Z250, Z350 e Supreme XT- 3M ESPE, Esthet-X e TPH Spectrum Dentsply, Charisma Heraeus Kulzer, Tetric Ceram Ivoclar Vivadent, Herculite XRV e Point 4 - Kerr), fotoativados pelo método contínuo (C) e pulse-delay (PD) (20 J.cm-2), por termogravimetria (TG) (n=1) e calorimetria exploratória diferencial (DSC) (n=3). Foram escolhidas duas temperaturas de TT: 100 e 170°C, aplicadas por 10 min, 24h após a fotoativação. A partir disto, avaliaram-se: 1) o grau de conversão (GC), por espectroscopia FT-Raman (n=3); 2) a resistência à flexão em três pontos (RF) (n=10); e 3) a dureza Knoop (KHN) para as faces topo e base (n=3) de quatro destes compósitos (Filtek Z250 e Supreme XT, Esthet-X e Point 4), após diferentes condições: imediatamente, 1h, 6h e 24h após a fotoativação e 24h após fotoativação seguida de TT a 100 ou 170°C. Os dados obtidos foram submetidos à análise de variância e ao teste de Tukey (nível de significância de 5%). Quanto ao GC (%), houve significância estatística para o fator material (p=0,000): Point 4 (68,42) > Z250 (63,05) = Esthet-X (61,69) > Supreme (54,27); condição (p=0,000): TT170 (73,20) = TT100 (73,58) > 24h (62,60) = 6h (60,18) > 1h (55,10) = imediato (53,66); e ativação (p=0,006): C (62,97) > PD (60,75). Também foram significantes as interações material × condição (p=0,007) e material × condição × ativação (p=0,013). Para a RF (MPa), foram encontradas significâncias estatísticas para os fatores material (p=0,000): Z250 (165,48) > Supreme (153,96) > Point 4 (131,30) = Esthet-X (128,06); e condição (p=0,000): TT170 (194,56) > TT100 (182,91) > 24h (150,88) > 6h (131,79) > 1h (111,77) > imediato (96,30); assim como para as interações: ativação × condição (p=0,000), material × condição (p=0,000) e material × ativação × condição (p=0,000). Para a dureza, foram encontradas significâncias estatísticas para os fatores: materialativação (p=0,000): Supreme C (82,46) > Supreme PD (80,29) = Z250 C (77,46) > Z250 PD (74,30) > Esthet-X C (69,17) > Esthet-X PD (65,67) > Point 4 C (57,21) = Point 4 PD (56,71); condição (p=0,000): TT170 (81,35) > TT100 (73,72) > 24h (70,36) > 6h (67,92) > 1h (64,99) > imediato (64,12) e face (p=0,000): topo (71,40) > base (69,40); assim como para as interações: material-ativação × face (p=0,011), material-ativação × condição (p=0,000) e face × condição (p=0,000). A partir dos resultados obtidos, pôde-se concluir que os TTs experimentais propostos foram capazes de aumentar as propriedades estudadas, sendo, de maneira geral, os resultados obtidos com 170°C melhores do que os com 100°C, e ambos melhores do que as demais condições. / Aiming to optimize chemical and mechanical properties of direct composites applied in an indirect way, with an association to experimental heat treatments (TT), it is necessary a thermal characterization, in a way to determine a safe temperature for the TT (below the significant mass loss temperature). Thus, the first step of this study was to perform the thermal characterization of ten commercial composites (Z100, Filtek Z250, Z350 and Supreme XT 3M-ESPE, Esthet-X and TPH Spectrum Dentsply, Charisma Heraeus Kulzer, Tetric Ceram Ivoclar Vivadent, Herculite XRV and Point 4 - Kerr) photoactivated by continuous (C) and pulse-delay (PD) methods (20 J.cm-2), by thermogravimetry (TG) (n=1) and differential scanning calorimetry (DSC) (n=3). After that, two temperatures were chosen for the TT: 100 and 170°C, which were applied for 10 min, 24h after photoactivation. Thus, some properties were evaluated for four composites (Filtek Z250 and Supreme XT, Esthet- X and Point 4): 1) degree of conversion (GC) by FT-Raman spectroscopy (n=3); 2) three-point bending test (RF) (n=10); and 3) Knoop hardness (KHN) for top and bottom surfaces (n=3). The conditions were: immediately, 1h, 6h and 24h after photoactivation and 24h after photoactivation followed by TT at 100 or 170°C. Data were analyzed by ANOVA and Tukeys test (level of significance of 5%). In relation to GC (%), there were statistical significance for the factors material (p=0.000): Point 4 (68.42) > Z250 (63.05) = Esthet-X (61.69) > Supreme (54.27); condition (p=0.000): TT170 (73.20) = TT100 (73.58) > 24h (62.60) = 6h (60.18) > 1h (55.10) = immediately (53.66); and activation (p=0.006): C (62.97) > PD (60.75); and for the interactions: material × condition (p=0.007) and material × condition × activation (p=0.013). For RF (MPa), statistical significance were found for the factors material (p=0.000): Z250 (165.48) > Supreme (153.96) > Point 4 (131.30) = Esthet-X (128.06); and condition (p=0.000): TT170 (194.56) > TT100 (182.91) > 24h (150.88) > 6h (131.79) > 1h (111.77) > immediately (96.30); and also for the interactions: activation × condition (p=0.000), material × condition (p=0.000) and material × activation × condition (p=0.000). For KHN, statistical significance were found for the factors material-activation (p=0.000): Supreme C (82.46) > Supreme PD (80.29) = Z250 C (77.46) > Z250 PD (74.30) > Esthet-X C (69.17) > Esthet-X PD (65.67) > Point 4 C (57.21) = Point 4 PD (56.71); condition (p=0.000): TT170 (81.35) > TT100 (73.72) > 24h (70.36) > 6h (67.92) > 1h (64.99) > immediately (64.12), and face (p=0.000): top (71.40) > bottom (69.40); as for the interactions: material-activation × face (p=0.011), material-activation × condition (p=0.000) and face × condition (p=0.000). By the results, it could be concluded that both proposed experimental TTs were capable of increasing the studied properties, with, in a general way, 170°C generating better mechanical properties than 100°C, and both better than the other conditions.
|
252 |
Avaliação clínica e laboratorial de resina composta em função da fotoativação com diferentes fontes de luz e densidades de potência / Clinical and laboratorial evaluation of resin composite light-cured with different curing units and power densitiesBenetti, Ana Raquel 27 July 2007 (has links)
O objetivo deste estudo foi avaliar o desempenho clínico e laboratorial de uma resina composta, considerando diferentes fontes de luz e densidades de potência, mantendo-se padronizada a densidade total de energia. O grau de conversão da resina composta foi determinado através de espectroscopia por transformada de Fourier. O grau de amolecimento em etanol foi obtido pela determinação da dureza Wallace, antes e após o armazenamento da resina composta em etanol a 75%. O desgaste foi mensurado por dois métodos: o teste da ACTA e o teste de escovação simulada. Paralelamente, investigou-se o desempenho clínico de restaurações de resina composta em dentes posteriores, submetidas aos mesmos protocolos de fotoativação. Restaurações de classe I de resina composta foram confeccionadas e fotoativadas por lâmpada de quartzo-tungstênio ou diodo emissor de luz a 300 mW/cm2, durante 40 segundos, ou a 600 mW/cm2, durante 20 segundos. As restaurações foram avaliadas, imediatamente e após 6 e 12 meses, por dois examinadores calibrados, de acordo com os critérios modificados de Ryge. Os dados laboratoriais foram submetidos à análise de variância a dois critérios e teste de comparações múltiplas de Newman-Keuls, ou ao teste t-pareado. Os dados clínicos foram analisados pelos testes Kappa, Fisher e McNemar (\'alfa\' = 0,05). Não foram constatadas diferenças significantes quanto aos diferentes protocolos no grau de conversão, no grau de amolecimento em etanol e no desgaste produzido pelo método da ACTA (p > 0,05). Para o teste de desgaste por escovação simulada, a fotoativação com diodos emissores de luz a 300 mW/cm2, durante 40 segundos, resultou em maior desgaste que os demais protocolos testados (p < 0,05). Adicionalmente, não foram observadas diferenças significantes quanto aos diferentes protocolos de fotoativação no desempenho clínico das restaurações, ao final de um ano de avaliação (p > 0,05) / The aim of this study was to evaluate the clinical and laboratorial performance of a resin composite light-cured with different light-curing units and power densities, at a standard energy density level. Degree of conversion of the resin composite was determined by Fourier transformed infrared spectroscopy. The degree of softening of the resin composite in ethanol was obtained by Wallace hardness measurements before and after storage in a 75% ethanol solution. Wear of the resin composite was acquired by two methods: ACTA wear and toothbrush abrasion. Additionally, the clinical performance of resin composite restorations submitted to the same light-curing protocols was followed up. Class I resin composite restorations were light-cured using either halogen lamp or light emitting diode at 300 mW/cm2 during 40 seconds or 600 mW/cm2 during 20 seconds. Restorations were evaluated immediately and after 6 and 12 months by two calibrated dentists, according to the modified Ryge criteria. The laboratorial data were submitted to two-way analysis of variance and Newman- Keuls multiple comparison test, or t-test. Clinical data were analyzed by Kappa, Fisher and McNemar tests (\'alpha\' = 0.05). No significant differences were observed for the different light-curing protocols in the degree of conversion, degree of softening in ethanol, and wear produced by the ACTA method (p > 0.05). For the toothbrush abrasion test, irradiation with the light emitting diode unit for 40 seconds at 300 mW/cm2 resulted in higher wear than the other light-curing protocols (p < 0.05). No significant differences were detected at the one-year clinical follow-up of the resin composite restorations submitted to the various light-curing protocols investigated in this study (p > 0.05).
|
253 |
Estudo in vitro do uso de vitrocerâmica bioativa em dentina afetada por cárie natural ou artificial: análise da resistência de união de compósitos / In vitro study of the use of bioactive glass ceramic in affected dentin by natural and artificial caries: analysis of composites\'s bond strengthMorais, Renata Costa de 21 January 2015 (has links)
O objetivo deste estudo in vitro foi avaliar a influência da aplicação de vitrocerâmica bioativa na resistência de união de sistemas adesivos em dentina afetada por cárie, natural ou artificial, comparativamente à dentina hígida. Cento e vinte molares humanos, 80 hígidos e 40 cariados, foram selecionados, sendo que 40 dentes hígidos foram submetidos à formação de cárie artificial por ciclagem de pH. Após a planificação das superfícies oclusais, os dentes foram separados em quatro grupos (n=10), segundo o tipo de sistema adesivo (convencional Adper Single Bond ou autocondicionante AdheSE) e tratamento do substrato: Grupo 1 - condicionamento ácido, lavagem e secagem + Biosilicato + sistema adesivo; Grupo 2 - idem ao Grupo 1, sem Biosilicato; Grupo 3 - sistema adesivo autocondicionante + Biosilicato; Grupo 4 - idem ao Grupo 3, sem Biosilicato. Após os tratamentos, os dentes foram restaurados com compósito (Opallis - FGM). Os dentes foram armazenados em água, a 37ºC, por seis meses e, em seguida, seccionados, perpendicularmente à interface adesiva, produzindo palitos de 0,9 mm2 de espessura. As amostras foram fixadas à Máquina de Ensaios Mecânicos (EMIC DL 2000 - 0,5 mm/min) e submetidas ao ensaio de microtração até a fratura. Após os ensaios, as fraturas foram observadas em microscópio digital (Keyence) e o modo de fratura da interface adesiva foi avaliado em microscopia eletrônica de varredura (JSM 5410, Sony). Os valores de Resistência de União (RU) foram submetidos à análise estatística (2-way ANOVA, Bonferroni, p<0,05) e verificou-se que, para os dentes hígidos, G1 apresentou os melhores valores de RU, com diferença estatística (p<0,05) em relação aos demais grupos, seguido de G3 e G2, que não apresentaram diferença (p>0,05) entre si. Os menores valores de RU para esse substrato ocorreram para G4, diferente (p<0,05) em relação aos demais grupos. Depois do substrato hígido, os melhores resultados de RU ocorreram para dentes cariados artificialmente, em níveis semelhantes (p>0,05) entre todos os grupos, com exceção para G2. Para o substrato cariado, não houve diferença significante (p>0,05) entre os grupos estudados. Em comparação aos demais substratos, grupos em que houve aplicação de Biosilicato apresentaram maior RU (p<0,05) quando comparados aos grupos não tratados. Nos grupos em que não houve aplicação de Biosilicato, a RU foi maior (p<0,05) para dentes hígidos que utilizaram sistema adesivo convencional. Para os demais substratos, não houve diferença significante (p>0,05). Não houve diferença significante (p>0,05) na RU em G4, independente do substrato utilizado. A análise do padrão de fratura mostrou predomínio de fraturas adesivas em todos os substratos e seus respectivos grupos. Conclui-se que a associação do sistema adesivo convencional e Biosilicato proporcionou os maiores valores de RU dente/adesivo. / The aim of this in vitro study was to evaluate, by means of microtensile test, the influence of bioactive glass ceramics application in the bond strength of adhesive systems with prior acid etching and natural or artificial caries-affected dentin compared to sound dentin. One hundred and twenty extracted human molars, 80 sound and 40 decayed, were selected, and 40 sound teeth were subjected to artificial caries formation by pH cycling. After occlusal surfacess regularization, teeth were divided into four groups (n = 10): Group 1 - etching, rinsing and drying + Biosilicate + adhesive system; Group 2 - same procedure as Group 1, without Biosilicate; Group 3 - self-etching adhesive system + Biosilicate; Group 4 - same procedure as Group 3, without Biosilicate. After all treatments, teeth were restored with composite (Opallis - FGM). Then, teeth were stored in water at 37°C for six months and sectioned perpendicular to the bonding interface, producing sticks 0.9mm2 thickness. All samples were fixed into a testing machine (EMIC DL 2000 to 0.5 mm/min) and submitted to microtensile bond strength test. The fractures were observed in digital microscope (Keyence) and the fracture pattern was analyzed by scanning electron microscopy (JSM 5410, Sony). The tensile bond strength values (TBS) (2-way ANOVA, Bonferroni, p<.05) were: for sound teeth, G1 showed the best TBS values with statistical difference (p<.05) compared to the other groups, followed by G2 and G3, which showed no significant difference (p>.05) among themselves. The smaller TBS occurred for G4, with significant difference (p<.05) compared to the other groups. Following sound substrate, the second best TBS results occurred for teeth with artificial caries-dentin, at similar levels (p>.05) between all groups, except for G2. For the decayed teeth, there was no significant difference (p>.05) between groups. Groups in which Biosilicate was applied had a higher TBS (p <.05) when compared to untreated groups, which TBS was higher (p <.05) for the sound teeth group on which conventional adhesive system was used. There was no significant difference for the other substrates (p>.05). Regardless the substrate used, there were no significant differences (p>.05) in G4. The fracture pattern analysis showed predominance of adhesive fractures in all groups. It was concluded that the combination of conventional adhesive system and Biosilicate provided the greatest TBS between tooth and adhesive.
|
254 |
Estudo in vitro do uso de vitrocerâmica bioativa em dentina afetada por cárie natural ou artificial: análise da resistência de união de compósitos / In vitro study of the use of bioactive glass ceramic in affected dentin by natural and artificial caries: analysis of composites\'s bond strengthRenata Costa de Morais 21 January 2015 (has links)
O objetivo deste estudo in vitro foi avaliar a influência da aplicação de vitrocerâmica bioativa na resistência de união de sistemas adesivos em dentina afetada por cárie, natural ou artificial, comparativamente à dentina hígida. Cento e vinte molares humanos, 80 hígidos e 40 cariados, foram selecionados, sendo que 40 dentes hígidos foram submetidos à formação de cárie artificial por ciclagem de pH. Após a planificação das superfícies oclusais, os dentes foram separados em quatro grupos (n=10), segundo o tipo de sistema adesivo (convencional Adper Single Bond ou autocondicionante AdheSE) e tratamento do substrato: Grupo 1 - condicionamento ácido, lavagem e secagem + Biosilicato + sistema adesivo; Grupo 2 - idem ao Grupo 1, sem Biosilicato; Grupo 3 - sistema adesivo autocondicionante + Biosilicato; Grupo 4 - idem ao Grupo 3, sem Biosilicato. Após os tratamentos, os dentes foram restaurados com compósito (Opallis - FGM). Os dentes foram armazenados em água, a 37ºC, por seis meses e, em seguida, seccionados, perpendicularmente à interface adesiva, produzindo palitos de 0,9 mm2 de espessura. As amostras foram fixadas à Máquina de Ensaios Mecânicos (EMIC DL 2000 - 0,5 mm/min) e submetidas ao ensaio de microtração até a fratura. Após os ensaios, as fraturas foram observadas em microscópio digital (Keyence) e o modo de fratura da interface adesiva foi avaliado em microscopia eletrônica de varredura (JSM 5410, Sony). Os valores de Resistência de União (RU) foram submetidos à análise estatística (2-way ANOVA, Bonferroni, p<0,05) e verificou-se que, para os dentes hígidos, G1 apresentou os melhores valores de RU, com diferença estatística (p<0,05) em relação aos demais grupos, seguido de G3 e G2, que não apresentaram diferença (p>0,05) entre si. Os menores valores de RU para esse substrato ocorreram para G4, diferente (p<0,05) em relação aos demais grupos. Depois do substrato hígido, os melhores resultados de RU ocorreram para dentes cariados artificialmente, em níveis semelhantes (p>0,05) entre todos os grupos, com exceção para G2. Para o substrato cariado, não houve diferença significante (p>0,05) entre os grupos estudados. Em comparação aos demais substratos, grupos em que houve aplicação de Biosilicato apresentaram maior RU (p<0,05) quando comparados aos grupos não tratados. Nos grupos em que não houve aplicação de Biosilicato, a RU foi maior (p<0,05) para dentes hígidos que utilizaram sistema adesivo convencional. Para os demais substratos, não houve diferença significante (p>0,05). Não houve diferença significante (p>0,05) na RU em G4, independente do substrato utilizado. A análise do padrão de fratura mostrou predomínio de fraturas adesivas em todos os substratos e seus respectivos grupos. Conclui-se que a associação do sistema adesivo convencional e Biosilicato proporcionou os maiores valores de RU dente/adesivo. / The aim of this in vitro study was to evaluate, by means of microtensile test, the influence of bioactive glass ceramics application in the bond strength of adhesive systems with prior acid etching and natural or artificial caries-affected dentin compared to sound dentin. One hundred and twenty extracted human molars, 80 sound and 40 decayed, were selected, and 40 sound teeth were subjected to artificial caries formation by pH cycling. After occlusal surfacess regularization, teeth were divided into four groups (n = 10): Group 1 - etching, rinsing and drying + Biosilicate + adhesive system; Group 2 - same procedure as Group 1, without Biosilicate; Group 3 - self-etching adhesive system + Biosilicate; Group 4 - same procedure as Group 3, without Biosilicate. After all treatments, teeth were restored with composite (Opallis - FGM). Then, teeth were stored in water at 37°C for six months and sectioned perpendicular to the bonding interface, producing sticks 0.9mm2 thickness. All samples were fixed into a testing machine (EMIC DL 2000 to 0.5 mm/min) and submitted to microtensile bond strength test. The fractures were observed in digital microscope (Keyence) and the fracture pattern was analyzed by scanning electron microscopy (JSM 5410, Sony). The tensile bond strength values (TBS) (2-way ANOVA, Bonferroni, p<.05) were: for sound teeth, G1 showed the best TBS values with statistical difference (p<.05) compared to the other groups, followed by G2 and G3, which showed no significant difference (p>.05) among themselves. The smaller TBS occurred for G4, with significant difference (p<.05) compared to the other groups. Following sound substrate, the second best TBS results occurred for teeth with artificial caries-dentin, at similar levels (p>.05) between all groups, except for G2. For the decayed teeth, there was no significant difference (p>.05) between groups. Groups in which Biosilicate was applied had a higher TBS (p <.05) when compared to untreated groups, which TBS was higher (p <.05) for the sound teeth group on which conventional adhesive system was used. There was no significant difference for the other substrates (p>.05). Regardless the substrate used, there were no significant differences (p>.05) in G4. The fracture pattern analysis showed predominance of adhesive fractures in all groups. It was concluded that the combination of conventional adhesive system and Biosilicate provided the greatest TBS between tooth and adhesive.
|
255 |
Análise fotoelástica das tensões geradas por diferentes planejamentos de próteses parciais fixas cimentadas sobre implantes cone morse / Photoelastic analyses of stress generated by different designs of cemented-retained fixed partial denture on morse taper implantsLuiz Ricardo Menani 28 August 2009 (has links)
O presente trabalho se propôs a avaliar, por meio de análise fotoelástica, o comportamento biomecânico de próteses parciais fixas cimentadas sobre implantes cone Morse (Titamax CM 4.0x11mm, Neodent) com coroas isoladas ou unidas, simulando a reabilitação de áreas posteriores com e sem a presença de elemento dental distal aos implantes, e ainda variando o tipo de material de recobrimento estético empregado na restauração protética (cerâmica ou resina), quando sobre estas próteses foram aplicadas diferentes tipos de cargas estáticas. Foi confeccionado um modelo fotoelástico simulando um espaço protético intercalado, com ausência do segundo pré-molar e primeiro molar, reabilitado por meio de quatro tipos de coroas cimentadas sobre dois implantes adjacentes: UC - coroas unidas com recobrimento estético em cerâmica; IC - coroas individuais com recobrimento estético em cerâmica; UR - coroas unidas com recobrimento estético em resina; IR - coroas individuais com recobrimento estético em resina. Análise fotoelástica qualitativa foi realizada sob diferentes condições de aplicação de carga na superfície oclusal das coroas: oclusal distribuída (10kgf), puntiforme simultânea (10kgf), puntiforme alternada no molar e no pré-molar (5kgf). A primeira análise foi feita na presença de contato proximal efetivo entre as próteses e o dente a distal dos implantes. A segunda análise foi realizada após a eliminação da coroa do dente distal no modelo fotoelástico. Registros fotográficos foram obtidos de cada situação de análise, a fim de facilitar a observação e comparação do padrão de distribuição das franjas isocromáticas em torno dos implantes. De acordo com os resultados obtidos, pode-se concluir que as restaurações cimentadas provocaram tensões no modelo fotoelástico mesmo quando da ausência de cargas oclusais. A ferulização das restaurações em cerâmica promoveu melhores distribuições das tensões isocromáticas em torno dos implantes. A presença do pilar distal com ponto de contato efetivo e ajustado nas restaurações modificou a distribuição das tensões isocromáticas, sendo que os estresses gerados pelas cargas oclusais foram também dissipados pelas réplicas dos dentes e transmitidos ao sistema fotoelástico. Ressalta-se a importância da obtenção de oclusão bem ajustada e equilibrada, para que haja adequada distribuição de forças aos implantes e osso de suporte, garantindo maior longevidade e previsibilidade de sucesso. / The purpose of this study was to evaluate the biomechanical behavior of fixed prostheses cemented over morse taper implants simulating a posterior rehabilitation with or without distal teeth to the implants, by use of a photoelastic stress analysis technique. Non-segmented or segmented ceramic or resin crowns were constructed over the implants and were evaluated when different static loads were applied. A photoelastic model simulating a prosthetic space without the second premolar and the first molar was done. The edentulous space was rehabilitated with crowns cemented over morse taper implants: UC = non-segmented ceramic crowns; IC = segmented ceramic crowns; UR = non-segmented resin crowns, and IR = segmented resin crowns. Qualitative photoelastic analysis was done with different loads conditions at the occlusal surface of the crowns: distributed occlusal (10kgf), punctiform over the first molar and second premolar simultaneously (5kgf), and punctiform over the first molar or second premolar alternatively (5kgf). The first analysis was done when the proximal contact was present between the crowns and the distal teeth to implants. The second was done after the remotion of the distal teeth at the photoelastic model. The resulting stress in all areas of the model was monitored and recorded photographically in the field of a circular polariscope. The fringe pattern findings were collected for the loadings subjected to each condition and loading position. According to the results obtained it would be concluded that the cemented restorations promoted stress even without occlusal loads. The ferulization of the ceramic restorations promoted a better stress distribution around the implants. The presence of the distal teeth with an effective and adjusted contact point modified the stress distribution. Stresses generated by occlusal loads was distributed by the replicas of the teeth and transmitted to the photoelastic system. The adjusted and balanced occlusion is important to the correct load distribution to the implants and support bone, which assure a better prognostic to the rehabilitation.
|
256 |
Efeito do armazenamento em água na resistencia de União de diferenets abordagens de adesão a dentina / Effects of water storage on resin-dentin bond strengths formed by different bonding approachesMartins, Gislaine Cristine 21 February 2008 (has links)
Made available in DSpace on 2017-07-24T19:22:09Z (GMT). No. of bitstreams: 1
Gislaine Cristine Martins.pdf: 4206631 bytes, checksum: c89ea8320c5c7cd1115382f7f0e02b50 (MD5)
Previous issue date: 2008-02-21 / The purpose of this study was to evaluate the effects of water storage on resindentin bond strengths [μTBS] formed by different adhesive bonding approaches. A flat superficial dentin surface the 24 human third molars were exposed and polished to create a standardized smear layer. The teeth were randomly distributed into four different: total-etch 3 step (Adper™ Scotchbond™ Multi-Purpose, 3M ESPE -
SBMP), and total-etch 2 step (Adper™ Single Bond 2, 3M ESPE - SB); self-etch 2 step (AdheSE, Ivoclar/Vivadent - AD); and self-etch 1 step (Adper™ Prompt™ LPop ™, 3M ESPE - LP). Following the adhesive application (n=6), resin composite crowns were incrementally placed (Filtek™ Supreme XT - 3M ESPE) in order to obtain bonded sticks, with a cross-sectioned area of about 0,8 mm2. The bonded sticks were randomly divided and assigned to be tested immediately [IM] (n=30) or after 6 months of water storage [6M](n=30). Two-way ANOVA and Tukey’s test showed that none of the adhesives showed degradation after 6 months, except SB,
which was the one that achieved the highest μTBS either in the immediate time (49.13 MPa) and after 6 months (40.27 MPa). LP showed the lowest μTBS in both periods of evaluation (18.35 and 18.34 MPa). AD and SBMP showed intermediate performance. But the SB showed lower μTBS significantly after storage anyway showed high results. Conclusion: Although a significant degradation was only
observed for SB, this was the adhesive that showed the highest μTBS after 6M of water storage. It seems that the microtensile test is not sensitive to detect degradation for adhesives with low immediate μTBS. / Este estudo objetivou avaliar o efeito do armazenamento em água na resistência de união [μTBS] de diferentes abordagens de adesão à dentina. As superfícies oclusais de 24 terceiros molares hígidos foram cortadas, planificadas e, a smear
layer padronizada. Os dentes foram divididos aleatoriamente em 4 grupos de acordo com a abordagem de união, ou seja, convencionais, de 3 passos (Adper™ Scotchbond™ Multi-Purpose, 3M ESPE - SBMP) e, de 2 passos (Adper™ Single
Bond 2, 3M ESPE -SB); autocondicionantes, de 2 passos (AdheSE, Ivoclar/Vivadent - AD) e, de 1 passo (Adper™ Prompt™ L-Pop™, 3M ESPE - LP). Após o procedimento adesivo (n=6) os dentes foram restaurados pela técnica
incremental com resina composta Filtek™ Supreme XT (3M ESPE). Obteve-se 240 espécimes em forma de palitos com área aproximada de 0,8 mm2. Dos espécimes obtidos para cada grupo (n=60), metade foi submetido ao teste de resistência de união imediato [IM] (n=30) e, a outra metade foi armazenada em água para realização do teste após 6 meses de armazenamento [6M](n=30). A ANOVA 2 fatores e o pós-teste de Tukey mostraram que não ocorreu degradação após 6M, exceto para o SB, ainda assim, a maior média da resistência de união IM e 6M foi do SB (49.13 e 40.27 MPa). O LP mostrou as menores médias nos dois períodos de avaliação (18.35 e 18.34 MPa). O AD e o SBMP apresentaram desempenho intermediário. Entretanto, o SB apresentou redução significativa da resistência de união após 6M, apesar disso, obteve os melhores resultados. Concluiu-se que
embora ocorreu uma degradação significativa para o SB, este sistema foi o que apresentou maior μTBS após 6 meses de armazenamento em água. O teste de microtração não foi sensível para detectar a degradação dos sistemas adesivos
com valores mais baixos de μTBS.
|
257 |
EFEITO DA INCLUSÃO DE PARTÍCULAS DE CARGA NA RADIOPACIDADE E EM PROPRIEDADES DE SISTEMAS ADESIVOS EXPERIMENTAIS / Effects of of filler addition to experimental adhesives on radiopacity and propertiesMartins, Gislaine Cristine 13 November 2012 (has links)
Made available in DSpace on 2017-07-24T19:22:25Z (GMT). No. of bitstreams: 1
Gislaine Cristine Martins.pdf: 4074240 bytes, checksum: e09201e7bd1d75eac883e17325cc0c46 (MD5)
Previous issue date: 2012-11-13 / The aim of this study was to evaluate the radiopacity, ultimate tensile strength (UTS), microhardness (KHN), degree of conversion (DC), water sorption (WS), solubility (SO), microtensile bond strength (μTBS) and of experimental dental
adhesives with increased addition of barium-borosilicate zirconia nanoparticles or glass microparticles. Methods: Ten experimental adhesive systems with different concentrations of zirconia nanoparticles [0(EX0), 15(EX15), 25(EX25), 35(EX35) and 50%(EX50) and barium-borosilicate oxide microparticles [0(R0), 30(R30), 40(R40), 50(R50) e 60%(R60)] were formulated based on the adhesive system Ambar (FGM).
The adhesive Adper Single BondTM 2 (SB, 3M ESPE) was used as commercial reference. For the radiopacity (n=5), KHN (n=5), WS (n=10) and SO (n=10) tests, adhesive specimens were constructed using a stainless steel mold (5.0 mm in diameter
and 1.0 mm in deep), while for UTS (n=5), a hourglass shape metallic matrix (10 mm long, 2 mm wide, and 1 mm deep with cross-sectional area of 0.8 mm2) was employed.The FTIR spectra of uncured and cured specimens of adhesives were used to determine the DC of the materials. For μTBS, adhesives were applied to flat dentin surfaces of third molars (n=7). Resin composite buildups were constructed and sectioned to obtain resin-dentin bonded sticks to tested immediately (IM) or after 6
months (6M) of water storage. Data were submitted to a one-way ANOVA and Tukey´s test (α=0.05). Results: All experimental bonding adhesives showed radiopacity similar
to enamel. Only R60 showed higher UTS than the other materials. The experimental adhesives showed higher KHN values when compared to the commercial SB. In general, the DC of the experimental solutions was not affected by filler addition and was statistically higher than SB. Although filler addition did not affect WS, it generally reduced the SO. Most of the experimental adhesives showed lower WS and SO than
SB. Conclusions: Both the addition of nanoparticles as microparticles were able to confer radiopacity to adhesives experimental, and adding load influence on the properties tested. In general, it can be said that the best performance was for the addition of microparticles in a concentration of 30%. / Objetivo: Este estudo objetivou avaliar a radiopacidade, resistência máxima à tração,(RMT), microdureza (KHN), grau de conversão (GC), sorção de água (SA),solubilidade (SO), resistência de união (μTBS) de sistemas adesivos experimentais
pela adição de nanopartículas de zircônia ou micropartículas de vidro de bárioborosilicato. Material e métodos: Dez sistemas adesivos experimentais com diferentes concentrações de nanopartículas de zircônia [0(EX0), 15(EX15), 25(EX25),
35(EX35) e 50%(EX50) ou com micropartículas de óxido de bário-borosilicato [0(R0), 30(R30), 40(R40), 50(R50) e 60%(R60)] foram formulados tendo como base o sistema
adesivo Ambar (FGM). O sistema adesivo Adper Single BondTM 2 (SB, 3M ESPE) foi utilizado como referência comercial. Foram confeccionados espécimes de adesivo para os testes de radiopacidade (n=5), KHN (n=5), SA (n=10) e SO (n=10) utilizando matriz metálica com 5,0 mm de diâmetro e 1,0 mm de profundidade e, para a RMT (n=5) uma matriz metálica com 10 mm de comprimento, 2 mm de largura, 1 mm de profundidade e, área de sessão transversal de 0,8 mm2. Os espectros FTIR foram obtidos de espécimes não polimerizados e polimerizados dos adesivos para determinar o GC dos materiais. Para μTBS, aplicou-se os adesivos na superfície de dentina de dentes molares humanos (n=7). Os dentes foram reconstruídos com resina composta e cortados para obtenção de espécimes em forma de palitos que foram testados imediatamente (IM) ou após 6 meses de armazenamento em água (6M). Os dados foram submetidos a ANOVA e pós-teste de Tukey´s (α=0,05). Resultados:Todos os sistemas adesivos experimentais mostraram radiopacidade semelhante a do esmalte dental. Apenas o R60 mostrou valores de RMT mais elevado que os outros materiais. Os sistemas adesivos experimentais apresentaram valores mais altos de dureza Knoop quando comparado ao SB. Em geral, o GC dos adesivos experimentais
não foi afetado pela adição de partículas e, significantemente superior ao SB. A maioria dos adesivos experimentais mostraram menor SA e SO que o SB.Conclusões: Tanto a adição de nanopartículas quanto de micropartículas foi capaz de conferir radiopacidade aos adesivos experimentais e, a adição de carga influenciou nas propriedades testadas. De modo geral, pode-se dizer que o melhor desempenho foi para a adição de micropartículas na concentração de 30%.
|
258 |
Efeito dos desafios erosivo ou erosivo/abrasivo sobre as estruturas dentárias adjacentes às restaurações realizadas com materiais contendo fluoreto ou cálcio / Effect of erosive and erosive/abrasive challenges on the dental hard tissues adjacent to restorations performed with materials containing fluoride or calciumViana, Ítallo Emídio Lira 29 January 2018 (has links)
Esse estudo avaliou in vitro o efeito dos desafios erosivo ou erosivo/abrasivo sobre materiais restauradores contendo fluoreto ou cálcio e sobre as estruturas dentárias adjacentes às restaurações realizadas com esses materiais. Fragmentos de esmalte e de dentina bovinos (4 mm × 4 mm × 2 mm), foram incluídos em resina acrílica e planificados. Uma cavidade padrão com dimensões 1,2 mm × 4 mm × 1,5 mm foi preparada nos espécimes, e restaurada de acordo com o material a ser testado: 1. Z350 - resina composta (Filtek Z350, 3M ESPE); 2. VB - compósito experimental contendo apenas vidros de bário; 3. DCPD30% - compósito experimental contendo 10% de vidros de bário e 30% partículas de fosfato di-cálcio di-hidratado (DCPD) funcionalizadas com dimetacrilato de dietilenoglicol (DEGDMA); 4. DCPD60% - compósito experimental contendo 60% partículas de DCPD funcionalizadas com DEGDMA; 5. Beautifil - GIOMER (Beautifil II, Shofu Dental Corporation); 6. Fuji IX - cimento de ionômero de vidro convencional de alta viscosidade (Fuji IX, GC Corporation); 7. Fuji II LC - cimento de ionômero de vidro modificado por resina (Fuji II LC, GC Corporation). Na sequência, os espécimes foram polidos e submetidos a dois tipos de tratamentos: erosão somente (n=10) ou erosão mais abrasão por escovação (n=10). A erosão foi realizada pela imersão dos espécimes em ácido cítrico a 0,3% (pH~2,6) por 5 min, seguido de 60 min de imersão em saliva artificial. Esse procedimento foi repetido 4×/dia, por 5 dias. A escovação foi realizada com uma suspensão de dentifrício padrão (Colgate Total 12 Mint Clean; 1450 ppm F-, como NaF) por 15 s (2 min de exposição total a suspensão de dentifrício), 2×/dia, 30 min após o primeiro e o quarto desafios erosivos. Ao final da ciclagem, a perda superficial (em ?m) do esmalte, da dentina e dos materiais restauradores foi determinada com um perfilômetro ótico. Para cada modelo (erosão e erosão-abrasão), os dados de perda superficial de esmalte, dentina e restauração foram analisados de maneira independente. Os dados foram analisados pelos testes de Kruskal-Wallis e Tukey. O nível de significância utilizado foi de 5%. No modelo de erosão, para esmalte, ambos cimentos ionoméricos apresentaram menor perda superficial do que o compósito Z350, apesar de Fuji II LC não ter se diferenciado significativamente dos grupos Beautifil e DCPD30%. Os outros grupos não foram diferentes de Z350 nem entre si. Para dentina, nenhum dos grupos foi diferente de Z350, com exceção de DCPD60%, o qual apresentou a maior perda superficial. Ambos cimentos ionoméricos apresentaram menor perda do que DCPD30%, Beautifil e DCPD60%. Em relação à restauração, os materiais Z350, Beautifil, VB, DCPD30% apresentaram perda superficial mínima, sem diferenças entre eles. Os cimentos ionoméricos apresentaram os maiores valores de perda, não se diferenciando de DCPD60%. No modelo erosão-abrasão, para esmalte, a menor perda superficial foi observada em Fuji II LC, sem diferença da Beautifil. Os outros grupos não se diferenciaram entre si nem da Beautifil. Para dentina, os grupos DCPD60%, Beautifil, Fuji II LC, Z350 e Fuji IX não se diferenciaram e, apresentaram menor perda superficial do que VB. Os cinco grupos citados também não foram diferentes de DCPD30%, com exceção de Fuji IX. Em relação à restauração, a maior perda foi observada para Fuji IX, sem diferenças de Fuji II LC e Beautifil. DCPD30%, Z350, VB e DCPD60% apresentaram valores mínimos de perda superficial, sem diferenças entre si. Concluiu-se que o cimento ionomérico Fuji II LC foi único capaz de proteger o esmalte adjacente à restauração contra desafios erosivos e erosivos/abrasivos, apesar de ter sido um dos materiais mais susceptíveis ao desgaste por ambos desafios. Para dentina, nenhum material exibiu efeito protetor. / This in vitro study evaluated the effect of erosive or erosive/abrasive challenges on restorative materials containing fluoride and calcium, and on the dental hard tissues adjacent to restorations performed with these materials. Enamel and dentin specimens (4 mm × 4 mm × 2 mm), obtained from bovine incisors, were embedded in acrylic resin, flattened and polished. In the specimens, a standard cavity of 1,2 mm × 4 mm × 1,5 mm was prepared and restored with the following materials: 1. Z350 - Composite resin without actives, Filtek Z350 (3MESPE); 2. VB - experimental composite containing barium glass only; 3. DCPD30% - experimental composite containing 10% of barium glass and 30% of DCPD particles functionalized with DEGDMA; 4. DCPD60% - experimental composite containing 60% of DCPD particles functionalized with DEGDMA; 5. Beautifil - GIOMER (Beautifil II, Shofu Dental Corporation); 6. Fuji IX - high viscosity glass ionomer (Fuji IX, GC Corporation); 7. Fuji II LC - resin-modified glass ionomer (Fuji II LC, GC Corporation). The specimens were polished again and then submitted to one of the two treatments: erosion only (n=10) or erosion plus toothbrushing abrasion (n=10). Erosion was performed by immersing the specimens in 0.3% citric acid solution (p~2.6), for 5 min, followed by 60 min exposure to artificial saliva. This procedure was repeated 4 times a day, for 5 days. Toothbrushing was performed with a slurry of a standard dentifrice (Colgate Total 12 Mint Clean; 1450 ppm F, as NaF), for 15 s (2 min total exposure time to the slurry), 2 times a day, 30 min after the first and last erosive challenges. At the end of cycling, enamel, dentin and restorative material surface loss (in ?m) were determined by optical profilometry. Data were analyzed by the Kruskal-Wallis and Tukey tests. The level of significance was 5%. In the erosion model, for enamel, both ionomeric cements presented lower surface loss than the Z350, although Fuji II LC did not differ significantly from Beautifil and DCPD30% groups. The other groups were no different from Z350 and from each other. For dentin, none of the groups were different from Z350, except for DCPD60%, which presented the highest surface loss. Both ionomeric cements presented lower loss than DCPD30%, Beautifil and DCPD60%. Regarding the restoration, the materials Z350, Beautifil, VB, DCPD30% showed minimal surface loss, with no differences between them. The ionomeric cements had the highest loss values, not differing from DCPD60%. In the erosion-abrasion model, for enamel, the lowest loss was observed for Fuji II LC, with no difference to Beautifil. The other groups showed no difference among them and from Beautifil. For dentin, the groups DCPD60%, Beautifil, Fuji II LC, Z350 and Fuji IX were no significant different and presented lower loss than VB. These five groups were also no different from DCPD30%, except Fuji IX. Regarding the restoration, the highest loss was observed for Fuji IX, with no difference from Fuji II LC and Beautifil. DCPD30%, Z350, VB and DCPD60% presented minimum values of surface loss, without differences between them. It was concluded that Fuji II LC ionomeric cement was the only material able to protect the enamel adjacent to the restoration against erosive and erosive/abrasive challenges, although it was one of the materials that was most susceptible to be wear off by both challenges. For dentin, no material exhibited a significant protective effect.
|
259 |
Influência de agentes clareadores na rugosidade de compósitos dentários / Influence of bleaching gels on roughness of dental compositesEduardo Varanda 18 December 2009 (has links)
O clareamento dental é o meio disponível mais simples, comum e conservador para o cirurgião-dentista proporcionar aos pacientes o padrão de cor de seus dentes mais desejado. Em alguns casos, os dentes que vão ser clareados podem apresentar restaurações realizadas com compósitos dentais, que são mais suscetíveis a alterações químicas, quando comparados a outros materiais restauradores. Alguns estudos mostraram que diferentes concentrações de agentes clareadores levaram a um aumento significativo da rugosidade superficial e das porosidades em compósitos dentais. Este estudo avaliou o efeito de dois agentes clareadores (Whiteness HP Blue 20%, Whiteness HP Max) sobre a rugosidade superficial de dois compósitos dentais, um micro-híbrido (Esthet X, Denstply) e outro nanoparticulado (Z 350, 3M ESPE). Um total de oito corpos de prova (9 x 2 mm) foram confeccionados com auxílio de uma matriz de teflon, sendo divididos em 4 grupos (Esthet X + Whiteness HP Blue 20%; Esthet X + Whiteness HP Max; Z 350 + Whiteness HP Blue 20%; Z 350 + Whiteness HP Max), sendo n=2. Os corpos de prova foram armazenados em saliva artificial neutra e, após 24 horas, foram polidos com discos de óxido de Alumínio (Sof-lex, 3M ESPE). Após sete dias de imersão salivar, cada corpo de prova foi levado a um microscópio de força atômica para obtenção do valor inicial de rugosidade superficial (Ra em nm). Em seguida, sem remover o corpo de prova do microscópio, o agente clareador foi aplicado sobre a superfície do corpo de prova, segundo as instruções do fabricante, de modo que permitisse uma posterior observação da mesma área do corpo de prova observada inicialmente, para obtenção do valor final de rugosidade superficial. Imagens em duas e três dimensões foram obtidas de cada corpo de prova para observação de alterações da topografia. Os resultados foram tratados estatisticamente por ANOVA e pelo teste de contraste Student-Newman-Keuls (p < 0,05). Não houve alteração significativa na rugosidade superficial (Ra) dos corpos da prova de compósitos micro-híbrido e nanoparticulado, submetidos aos agentes clareadores Whiteness HP Blue 20% e Whiteness HP Maxx. No entanto, independente do agente clareador utilizado, foram observadas maiores alterações topográficas nas imagens de microscopia de força atômica da superfície do compósito micro-híbrido do que nas imagens do nanoparticulado. / Dental bleaching is the simplest, the most common and conservative available way for dentists to offer their patients the standard color of teeth more desired. In some cases, the teeth that will be bleached may include restorations made of resin composites, which are more prone to chemical alteration compared with other restoration materials. Some studies have showed that different concentrations of bleaching gels might lead to a significant increase in surface roughness and amount of porosities in composite resins. This study evaluated the effect of two bleaching gels (Whiteness HP Blue 20%, Whiteness HP Max) on surface roughness of two resin composites, micro-hybrid (Esthet X, Denstply) and nanoparticled (Z350, 3M ESPE). A total of eight specimens (9 x 2 mm) were produced with a Teflon mold help, and were divided into four groups (Esthet X + Whiteness HP Blue 20%; Esthet X + Whiteness HP Max; Z 350 + Whiteness HP Blue 20%; Z 350 + Whiteness HP Max), with n=2. They were stored in neutral artificial saliva and, after 24 hours, were polished with aluminium oxide discs (Sof-lex, 3M ESPE). After seven days of salivary immersion, each specimen was taken to an atomic force microscope for recording initial value of surface roughness (Ra in nm). After that procedure, without removing the specimen from microscope, the bleaching gel was applied on the surface of the specimen, following manufacturers instructions, in order to allow posterior observation of the same area of the specimen initially observed, for recording the final value of surface roughness. Two-dimensional and 3D images were taken from each specimen group for observation of surface alterations. The results were statistically analyzed by ANOVA and the SNK test (p< 0.05). There were no statistically significant differences in the surface roughness (Ra) for specimens of micro-hybrid and nanoparticled composites, submitted to the bleaching agents Whiteness HP Blue 20% and Whiteness HP Maxx. However, there were noticed larger surface alterations in atomic force microscope images on the surface of micro-hybrid composites than on the nanoparticled, independently of the bleaching agent used.
|
260 |
Influência da umidade, temperatura e tempo de irradiação sobre propriedades físicas de resinas compostas usadas na ortodontiaSostena, Michela Melissa Duarte Seixas [UNESP] 31 July 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:03Z (GMT). No. of bitstreams: 0
Previous issue date: 2009-07-31Bitstream added on 2014-06-13T20:41:11Z : No. of bitstreams: 1
sostena_mmds_dr_bauru.pdf: 1109599 bytes, checksum: 95e32b77f35f4c401d09a1dff43e0434 (MD5) / O propósito deste estudo foi avaliar as propriedades de resistência mecânica, o grau de conversão e a temperatura de transição vítrea de três resinas ortodônticas fotopolimerizáveis (Fill Magic, Ortho Lite Cure e Transbond XT), em função da umidade, temperatura, tempo de irradiação e da densidade de potência do aparelho fotopolimerizador. A resistência mecânica foi avaliada por meio de ensaios mecânicos de cisalhamento e de dureza Vickers. O grau de conversão e a temperatura de transição vítrea foram avaliados por espectroscopia no infravermelho e mecânica, respectivamente. Os resultados demonstraram que as resinas Ortho Lite Cure e Transbond XT apresentaram valores de resistência ao cisalhamento e dureza estatisticamente superior aos obtidos para resina Fill Magic, embora a resina Fill Magic tenha alcançado os maiores valores de grau de conversão. Maiores valores de temperatura de transição vítrea foram observados para as resinas Ortho Lite Cure e Transbond XT. Estes resultados podem estar relacionados a diferenças estruturais e no conteúdo inorgânico dos materiais. O tempo de irradiação e a densidade de potência do aparelho fotopolimerizador influenciaram significativamente nas propriedades avaliadas. O uso de um menor tempo de irradiação associado a uma menor densidade de potência ocasionou uma redução nos valores de resistência mecânica, grau de conversão e temperatura de transição vítrea. A umidade não influenciou na propriedade de dureza dos materiais. Por outro lado, o tratamento térmico influenciou no comportamento mecânico dos materiais e promoveu uma diminuição da temperatura de transição vítrea. / The purpose of this work was evaluate the mechanical resistance, the degree of conversion and glass transition temperature properties of three orthondontic light-cured resins (Fill Magic, Ortho Lite Cure and Transbond (XT) in function of the humidity, temperature, irradiation time and power density of the light-curing unit. The mechanical resistence was evaluated through shear strength and Vickers hardness measurements. The degree of conversion and glass transition were evaluated by infrared and mechanical spectroscopy, respectively. The results showed that the Ortho Lite Cure and Transbond XT resins have shear bond strength and hardness statistically higher than Fill Magic resin, to have reached a higher degree of conversion. Higher glass transition temperature was observed for the resins Ortho Lite Cure and Transbond XT. These results may be related to differences in the structure and in the inorganic content of materials. The irradiation time and power density of the light-curing units significantly influenced the evaluated properties. The use of a shorter time of irradiation associated to a lower power density caused a reduction in the values of mechanical resistance, degree of conversion and glass transition temperature. The humidity did not influence the hardness of resins. On the other hand, the heat treatments influenced the mechanical behavior of resins and it promoted in the glass transition temperature.
|
Page generated in 0.1577 seconds