• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 32
  • 1
  • 1
  • Tagged with
  • 34
  • 23
  • 21
  • 11
  • 11
  • 7
  • 7
  • 7
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Avaliação in vitro do colar de implantes cone Morse de diferentes diâmetros sob cargas cêntrica e excêntrica: estudo por meio da Interferometria Eletrônica por Padrões de Speckle / In vitro evaluation of the collar of Morse taper dental implants with different diameters under centric and eccentric loads: an electronic speckle pattern interferometry study

Sergio Rodrigues Sizo 15 September 2011 (has links)
Cargas oclusais excessivas podem promover tensões exageradas às estruturas de implantes/pilares/próteses, resultando em deformação, desadaptação ou mesmo fratura dos componentes e do próprio implante. Além disso, tais sobrecargas podem gerar necrose por compressão e perda óssea peri-implantar e, ainda, a ocorrência de microdeslocamentos na interface de conexão implante-pilar (I-P) ocasionando a formação de fendas propícias à colonização bacteriana, o que pode levar ao desenvolvimento de peri-implantite, contribuindo para o insucesso do conjunto. O presente estudo objetivou avaliar, por meio de uma técnica já amplamente utilizada na Engenharia e na Física a Interferometria Eletrônica por Padrões de Speckle (ESPI) as deformações a nível do colar de implantes com conexão cônica interna (cone Morse) de diferentes diâmetros (Kopp 4,3/5,5 mm e Neodent 3,5/5,0 mm), sob dois tipos (cêntrica e excêntrica) e intensidades (50 N e 100 N) de cargas, similares as quais os implantes ficam expostos durante a função mastigatória. Testou-se a hipótese de que a deformação do colar do implante seria inversamente proporcional ao diâmetro do implante. Além disso, discutiu-se vantagens e limitações da técnica ESPI frente a outros métodos comumente utilizados na avaliação de tensões. As maiores deformações foram sempre associadas às cargas excêntricas, com exceção do G1-Kopp. A maior deformação ocorreu no G1-Neodent sob carga excêntrica de 100 N e a menor, no G2-Neodent sob carga cêntrica de 50 N. A técnica ESPI mostrou-se altamente sensível e reprodutível para avaliar deformações a nivel do colar de implantes sendo possível confirmar a hipótese inicial, visto que a maior deformação esteve sempre associada aos implantes de menor diâmetro, em ambos os sistemas de implante pesquisados. / Occlusal overloading may promote excessive stresses to the implants/abutments/prosthesis, resulting in deformation, misfit or fracture of the components, until the implants. Futhermore, strains of the implant-abutment connection can cause the formation of microgaps propitious to bacterial colonization, which leads to the development of peri-implant sites, leading to the failure of the rehabilitation. This study aimed to evaluate, by a technique widely used in the engineering and physics Electronic Speckle Pattern Interferometry (ESPI) the strains related to the implant collar with internal tappered connection (Morse taper) with different diameters (Kopp 4.3/5.5 mm and Neodent 3,5/5,0 mm), under two types (centric and eccentric) and intensities (50 N and 100 N) of loads, similar which implants are exposed during masticatory function. We tested the hypothesis that the strains of the implants collar would be inversely proportional to the diameter of the implant. In addition, the survey discussed the advantages and limitations of the ESPI technique over other methods commonly used to assess strains. The largest strain was always associated with eccentric loads, except for G1-Kopp. The largest strain occurred in the G1-Neodent under the eccentric loads of 100 N and the lowest in the G2-Neodent under the centric loads of 50 N. The ESPI technique was a highly sensitive and reproducible to evaluate the strains at the level of the collar of implants being possible to confirm the initial hypothesis, since most strains was always associated with narrower-diameter implants in both implant systems studied.
22

Avaliação dos Limiares Dolorosos por Algometria de Pressão na Síndrome do Túnel do Carpo

BERNADINO, Silvya Nery 03 July 2015 (has links)
Submitted by Fabio Sobreira Campos da Costa (fabio.sobreira@ufpe.br) on 2016-04-12T11:42:16Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) TESE DIGITAL COM FICHA SEM ASSINAT.pdf: 7130468 bytes, checksum: 91f192851345cb3030b04950f2f04c1e (MD5) / Made available in DSpace on 2016-04-12T11:42:17Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) TESE DIGITAL COM FICHA SEM ASSINAT.pdf: 7130468 bytes, checksum: 91f192851345cb3030b04950f2f04c1e (MD5) Previous issue date: 2015-07-03 / INTRODUÇÃO: A avaliação dos limiares dolorosos em pacientes com neuropatias compressivas é de grande utilidade quando se tenta explicar a presença de sintomas generalizados. Sabe-se que no processo de sensibilização periférica a liberação de prostaglandina e bradicinina altera receptores específicos TRPV1 levando a redução do limiar de disparo da fibra nervosa. Essa repetição leva a uma ampliação no campo receptivo cerebral com consequente sensibilização central. A síndrome do túnel do carpo (STC) é a mononeuropatia mais frequentemente diagnosticada, porém os estudos de limiares dolorosos são escassos e não avaliam segundo o grau de comprometimento do nervo. MÉTODOS: Foram avaliadas 160 mulheres divididas em Grupo A) Controle (n=40) e grupo B) pacientes com quadro clínico de síndrome do túnel do carpo (n=120) subdivididas de acordo com o grau de comprometimento neurofisiológico do nervo mediano no punho seguindo a classificação de Pádua em Grupo I (n=20): pacientes com sintomas sugestivos, porém sem confirmação da neuropatia do nervo mediano no punho (NNMP); Grupo II (n=20): NNMP discreta; Grupo III (n=20): NNMP leve; Grupo IV (n= 20): NNMP moderada; Grupo V (n=20): NNMP acentuada; Grupo VI (n=20): NNMP extrema. Realizaram-se algometria de pressão, estudo de condução nervosa, sensibilidade discriminatória entre dois pontos e foi aplicado o questionário de gravidade de sintomas de Boston. A algometria foi realizada em território inervado pelo nervo mediano após a passagem através do túnel do carpo, na região inervada pelo nervo cutâneo palmar, em território inervado pelo nervo ulnar e em áreas proximais ao túnel do carpo. Os valores algométricos em um mesmo grupo seguiram padrão de normalidade (Kolmogorov-Smirnov p <0.05). As comparações entre os grupos foram não-paramétricos (Shapiro- Wilk p= 0.1955) e, portanto, o teste de Kruskal-Wallis foi utilizado e o poshoc de Dunn quando houve diferença significativa. RESULTADOS: Houve diferença extremamente significativa entre o grupo controle e os grupos com NNMP discreta, NNMP leve, NNMP moderada e NNMP acentuada (p<0,0001). Porém, não houve diferença significativa em alguns pontos tanto na presença dos sintomas sem NNMP como na NNMP extrema. Portanto, os limiares reduzem à medida que a patologia se inicia e progride até certo ponto. Quando já não são mais obtidos potenciais sensitivos ou motores nos estudos de condução nervosa, os limiares dolorosos retornam aos valores próximos da normalidade. Sugere-se esse resultado à provável destruição de fibras finas, na qual já pode haver hipoestesia em substituição da hiperalgesia. Quanto à sensibilidade discriminatória entre dois pontos foi observado que quanto mais acentuada a NNMP maiores os valores da sensibilidade discriminatória, havendo diferença significativa entre o controle e os grupos III, IV, V e VI (p<0,0001). Quanto à escala de gravidade de sintomas, as queixas relacionadas à dor e dormência ou formigamento foram mais evidentes nos grupos I, III, IV e V. Enquanto a incapacidade de realizar atividades cotidianas predominou nos grupos III, IV e V. CONCLUSÃO: O limiar para sensação dolorosa é menor em pacientes com síndrome do túnel do carpo, tanto em território inervado pelo nervo mediano como em outras áreas. / INTRODUCTION: Pain threshold evaluation in compressive neuropathy is very useful for explain generalized symptoms. About peripheral sensitization process in the release of bradykinin and prostaglandin alters specific TRPV1 receptors leading to reduction of nerve fiber firing threshold. This repetition leads to a brain receptive field expansion with consequent central sensitization. Carpal tunnel syndrome (CTS) is the most frequently diagnosed mononeuropathy, but painful thresholds studies are scarce and not evaluate according to nerve impairment degree. METHODS: We have evaluated 160 female divided into Group A) Control (n = 40), B) patients with symptoms suggestive of CTS (n = 120) subdivided according to the neurophysiologic impairment of median nerve at the wrist according to Padua classification into Group I (n = 20): patients with symptoms suggestive, but without confirmated wrist median nerve neuropathy (WMNN); Group II (n = 20): Discrete MNNW; Group III (n = 20): Light MNNW; Group IV (n = 20): Moderate MNNW; Group V (n = 20): Severe MNNW; Group VI (n = 20): Extreme MNNW. METHODS: Pressure algometry was held in 320 hands, as well as nerve conduction study and discriminatory sensitivity between two points. The Boston symptom severity questionnaire were applied to the patients. The algometry was held on areas innervated by the median nerve after crossing through the carpal tunnel, palmar cutaneous territory, ulnar cutaneous territory and proximal areas to the carpal tunnel. RESULTS: The algometry values within the same group were normal (Kolmogorov-Smirnov p <0.05). Comparisons between groups were non-parametric (Shapiro-Wilk p = 0.1955) and thus, the Kruskal-Wallis test was used and when there the significant difference pairwise comparisons were performed whit the Dunn test (poshoc). RESULTS: The comparison of algometry data showed extremely significant differences between control group and groups with discrete MNNW, light MNNW, moderate MNNW and severe MNNW (p <0.0001). However, there was no significant difference at some points both in the presence of symptoms without MNNW as in MNNW extreme. Therefore, pain thresholds showed direct relation to MNNW severity to a certain point. When sensory or motor potential were no longer obtained, painful thresholds returned close to normal values. We suggest this result could be due to small fibers destruction, when hyperalgesia would be replaced by hypoesthesia. As for discriminatory sensitivity between two points has been observed higher values were obtained as most affected by MNNW with a significant difference between control group and III, IV, V and VI groups (p <0.0001). As for the scale of severity of symptoms, the complaints with pain and numbness or tingling were more evident in I, III, IV and V groups. About the inability to perform daily activities predominated in III, IV and V groups. CONCLUSION: Pain threshold is lower in patients with carpal tunnel syndrome, either the median nerve innervated area or another areas.
23

Desenvolvimento de técnicas para caracterização de concreto seco utilizado na fabricação de peças de concreto para pavimentação intertravada. / Development of techniques to characterize dry concrete used on the precast paving blocks for interlocking pavement.

Marchioni, Mariana Lobo 03 October 2012 (has links)
O concreto seco, também chamado de concreto sem abatimento (no-slump) é utilizado na produção de artefatos de cimento, como por exemplo em peças de concreto para pavimentação, blocos para alvenaria e tubos de concreto e ainda como camada de subbase de pavimentos com a técnica de concreto compactado a rolo. A técnica de conformar concretos com reduzido teor de umidade através de equipamentos que aplicam simultaneamente compressão e vibração é amplamente utilizada na produção de artefatos de concreto, como as peças de concreto para pavimentação intertravada. Para as peças de concreto o desafio é ainda maior, pois as especificações de resistência característica à compressão podem chegar a 50 MPa. A principal característica do concreto seco é o baixo teor de água e elevada coesão, necessitando de energia de compactação e vibração para a eliminação de vazios e o concreto assumir a forma desejada. Esta técnica permite a desfôrma imediata, que garante elevada produtividade e consequente diminuição dos custos de produção. Já a compactação permite obter componentes de concreto com menor consumo de cimento se comparados ao concreto plástico. Diferentemente de toda literatura e metodologias de dosagem encontradas para o concreto plástico, o concreto seco encontra barreiras técnicas para a aplicação de metodologias que otimizem sua dosagem, em formulações empíricas que não levam em conta de forma adequada as características dos agregados, características estas diretamente ligadas à compacidade das peças, que por sua vez tem grande influência nas características do produto final. Além disto, há poucos estudos do comportamento reológico do concreto seco, que influenciam a fluidez e coesão da do concreto e que irão determinar a produtividade e qualidade da produção. Dessa forma, neste trabalho é apresentado uma metodologia para caracterização do concreto seco nos estados fresco e endurecido que permite o desenvolvimento sistemático de formulações com maior facilidade de compactação e que também resulte na melhoria do desempenho das peças e diminuindo a necessidade de testes em escala real. O método se baseia em produzir em laboratório um corpo de prova que reproduz as condições de moldagem de uma vibroprensa, eliminando-se a variável da vibração e padronizando as condições de compressão. Nos corpos-de-prova são avaliadas características nos estados fresco e endurecido, além de aspectos do comportamento reológico do concreto, através de técnicas de reologia compressiva. Para aferir a metodologia foram utilizadas amostras de referência produzidas em uma fábrica de peças de concreto. Com a metodologia proposta, foi possível atingir 90% da resistência mecânica das peças produzidas em uma vibroprensa de alta compactação. Sendo assim esta metodologia poderá ser utilizada em estudos de dosagem de concreto seco, portanto o trabalho desenvolvido é indicado na utilização de dosagens de concreto seco, obtendo-se maior ecoeficiência, a medida que otimiza o consumo de cimento da mistura e facilita o estudo de dosagem de materiais alternativos em substituição aos agregados convencionais. / The dry concrete, also known as earth moist concrete or no-slump concrete, is most used to manufacture precast concrete products, as paving blocks, masonry blocks and concrete tubes, and also in rolled compacted concrete pavement. Its most important property is the low water content, and it requires mechanical equipment for its compactation. Paving blocks are normally manufactured using vibrocompression equipment, which at the same time applies both compaction and vibration resulting in paving blocks with high durability and mechanical resistance. Even though this technique is highly used it still lacks studies on some important steps of the manufacturing process. The mix design techniques are mostly empirical and dont deeply consider the aggregate characteristics, that are connected with its compacity and, by that, the characteristics of the paving block. Also, there are only a few studies of the rheology characteristics of dry concrete, which relates with de manufacturing process and the easiness that the mix is compacted. So, the object of this study is to develop a dry concrete characterization methodology that allows the systematic development of mix designs that are easily compacted and also improves the performance of the paving blocks.
24

Avaliação da resistência à fratura de dentes endodonticamente tratados, reconstituídos com pinos intra-radiculares, quando submetidos à ciclagem dinâmica / Evaluation of the fracture strength of endodontically treated teeth, reconstructed with post and cores, when submitted to the dynamic loading

Fernando Furtado Antunes de Freitas 26 November 2007 (has links)
Neste estudo, foi avaliada a resistência à fratura de dentes que, já tratados endodonticamente, foram reconstruídos proteticamente com uma coroa de liga de NiCr (Verabond II), a qual era apoiada sobre núcleos compostos por diferentes materiais, obtidos por diferentes técnicas, cimentados no remanescente radicular com o ionômero de vidro Rely X Lutting 2, o qual é acrescido de resina composta. Esses núcleos eram do tipo metálico fundido, no grupo NMF; no grupo ANATO, a resina composta Filtek Z250 (3M ESPE, St. Paul-MN, USA) constituía o núcleo, contendo um pino de fibra de vidro (Reforpost Fibra de Vidro RX, Ângelus Indústria de Produtos Odontológicos Ltda.,Londrina-PR); este mesmo tipo de pino era utilizado no grupo PFFV, sendo diretamente cimentado, sem acréscimo de resina; finalmente, no grupo PFM, um pino metálico (no 064, FKG Dentaire S. A., La Chaux-de-Fonds, Swiss) era cimentado da mesma maneira descrita para o grupo anterior. Os remanescentes radiculares eram provenientes de dentes caninos superiores humanos, distribuídos aleatoriamente, compondo assim os quatro grupos, cada um com 10 espécimes: Os espécimes, após 24 horas da cimentação, foram submetidos a esforços cíclicos, em uma Máquina Eletro-Mecânica de Fadiga, aplicados no sentido do longo eixo dental, com carga de 20 N, na freqüência de 2,0 Hz, assim perfazendo um total de 250.000 ciclos. Excetuando-se 2 corpos-de-prova cujos núcleos soltaram-se da raiz, durante a carga cíclica, todos os demais foram submetidos a uma carga de compressão, numa máquina universal de ensaios (Kratos - Dinamômetros Ltda. São Paulo-SP), regulada na velocidade de 0,5 mm/min, com a força aplicada na face palatina da coroa, num ângulo de 45º em relação ao longo eixo dental, até a ocorrência da fratura radicular. Os valores de resistência encontrados foram os seguintes, em ordem decrescente: 47,677 kgf para o grupo NMF, 34,921 kgf para o PFM, 31,354 kgf para o PFFV e, 27,172 kgf para o ANATO. A análise de variância aplicada aos valores originais apontou diferença entre os grupos estudados e um subseqüente teste de Tukey (p<0,05) permitiu verificar semelhanças entre todos eles, com diferença significante apenas entre os grupos NMF e ANATO. / In this study, was evaluated the strength of endodontically treated teeth, had been reconstructed with a crown of NiCr alloy (Verabond II), which was supported by a post and core for different materials, gotten for different techniques, cemented in the root with the glass ionomer Rely X Lutting 2, which is increased of composed resin. These diferents post and cores were of the casting metallic type, in group NMF; in group ANATO, the composed resin Filtek Z250 (3M ESPE, St. Paul-MN, USA) was the core, contend a glass fiber post (Reforpost Fibra de Vidro RX, Ângelus Indústria de Produtos Odontológicos Ltda., Londrina - PR); this exactly type of post was used in group PFFV, being directly cemented, without resin addition on the core; finally, in group PFM, a metallic post (064, FKG Dentaire S. , La Chaux-of-Fonds, Swiss) were cemented in the same way described for the previous group. All the roots were proceeding from maxillary human canines, randomly distributed, thus composing the four groups, each one with 10 specimens: The specimens, after 24 hours of the cimentation, had been submitted the cyclical efforts, in an Electromechanical Machine of Fatigue, applied in the direction of the long dental axle, with load of 20 N, in the frequency of 2 Hz, thus occuring a total of 250.000 cycles. Excepting 2 body-of-test whose post and cores had been freed of the root, during the cyclical load, all excessively had been submitted to a compression load, in a universal machine of assays (Kratos - Ltda. Dinamômetros. São Paulo - SP), regulated in the speed of 0,5 mm/min, with the force applied in the lingual face of the crown, in an angle of 45º in relation to the long dental axle, until the occurrence of the any root fracture. The joined values of resistance had been following, orderly the decreasing one: 47,677 kgf for group NMF, 34.921 kgf for the PFM, 31,354 kgf for the PFFV and, 27,172 kgf for the ANATO. The analysis of variance applied to the original values pointed difference between the studied groups and a subsequent Tukey test (p<0,05) it allowed to verify similarities between all they, with significant difference only between groups NMF and ANATO.
25

Análise de fatores pessoais de risco para ocorrência e gravidade de síndrome do túnel do carpo. / Age, body mass index and wrist index as risk factors for carpal tunnel syndrome and relationship to severity of nerve conduction abnormality

Kouyoumdjian, João Aris 08 November 2000 (has links)
Made available in DSpace on 2016-01-26T12:51:13Z (GMT). No. of bitstreams: 1 joaoariskouyoumdjian_tese.pdf: 1771362 bytes, checksum: 1fca40a2aced85e1fea351cb38a169bd (MD5) Previous issue date: 2000-11-08 / Between September/98 and May/99, 210 symptomatic carpal tunnel syndrome (CTS) patients were studied. All had bilateral nerve conduction studies and none had been surgically treated. Peripheral neuropathy was excluded. Three groups were defined according to the severity of nerve conduction changes: mild = median distal sensory latency, wrist-index finger, 14 cm (P2), 3.7 to 4.4 ms or sensory median/ulnar difference ³ 0.50 ms or median palm latency ³ 2.3 ms; moderate = P2 ³ 4.5 ms; severe = unrecordable sensory nerve action potential at P2. All latencies were measured to the negative peak. Only the right hand was considered for this study (200 hands), regardless of the electrophysiological findings in the left hand. Another group of 320 subjects without any CTS symptomatology or any known systemic disorders was used as control. The mean age was 50.3 ± 10.8 years for the study group (87.6% female) and 47.3 ± 14.8 years old for the controls (89.1% female). Body mass index (BMI) was 28.4 ± 5.0 for the CTS group and 25.4 ± 4.7 for controls (p < 0.001). Right wrist index (WI) was 0.706 ± 0.041 for the CTS group and 0.689 ± 0.037 for controls (p < 0.001). Logistic regression analysis for risk of having CTS showed an adjusted odds ratio of 1.11 (95% CI 1.07-1.16) per unit increase for BMI and 1.11 (95% CI 1.05-1.16) per 0.01 increase for WI. An ordinal polychotomous logistic regression analysis of the relationship between these factors and the electrophysiological severity of CTS showed proportional odds ratios (mild to severe) of 1.20 (95% CI 1.00-1.30) for 5 years increase in age and 1.10 (95% CI, 1.00-1.20) for 0.01 increase in WI. Higher BMI did not increase the risk of severe CTS. The conclusions were: 1. The variables WI and BMI were higher in CTS cases (p < 0.001). 2. More severe nerve conduction abnormalities were associated with higher age and WI but not with higher BMI. / Foram estudados 210 pacientes com diagnóstico clínico e eletrofisiológico de síndrome do túnel do carpo (STC) entre setembro/1998 e maio/1999. Os casos foram divididos em 3 grupos com progressiva gravidade eletrofisiológica: leve = diferença de latência mediano/ulnar (14 cm, IV dedo) ³ 0,5 ms ou latência palmar mediano (8 cm) ³ 2,3 ms ou latência distal mediano (14 cm) punho-II dedo (P2) entre 3,7 e 4,4 ms; moderado = P2 > 4,4 ms; grave = ausência de potencial de ação sensitivo em P2; todas latências medidas no pico. Todos casos tiveram estudo bilateral, sendo excluídos casos com cirurgia prévia ou evidência de neuropatia periférica. Foram considerados apenas os casos de STC direito independente dos achados do lado oposto (200 mãos). Foi constituído grupo controle (GC) de 320 pessoas sem qualquer sintomatologia compatível com STC ou doenças sistêmicas conhecidas, pareando para sexo e idade. A idade média foi de 50,3 ± 10,8 para STC e 47,3 ± 14,8 anos no GC; sexo feminino 87,6% (STC) e 89,1% (GC); IMC 28,4 ± 5,0 (STC) / 25,4 ± 4,7 (GC) com p < 0,001; IP direito 0,706 ± 0,041 (STC) / 0,689 ± 0,037 (GC) com p < 0,001. Houve incremento do IP e idade com a maior gravidade eletrofisiológica do STC, o mesmo não ocorrendo com IMC. A análise de regressão logística multivariada para avaliar risco de apresentar STC revelou odds ratio ajustado de 1,11 (IC 95% 1,07- 1,16) para IMC (incremento de 1 unidade) e de 1,11 (IC 95% 1,05- 1,16) para IP (incremento de 0,01 unidade). A análise de regressão logística ordinal politômica para avaliar fator de risco de gravidade de condução nervosa em pessoas com STC revelou odds ratio proporcional (casos leve a grave) de 1,20 (IC 95% 1,00-1,30) para incrementos de 5 anos na idade e 1,10 (IC 95% 1,00-1,20) para incrementos de 0,01 no IP. O IMC não determinou risco para desenvolvimento de STC de maior gravidade. Os resultados permitem concluir: 1. As variáveis IP e IMC estão mais elevadas (p < 0,001) no STC; 2. O aumento da gravidade eletrofisiológica do STC está associado ao incremento de idade e IP, porém não ao do IMC.
26

Avaliação da resistência à fratura de dentes endodonticamente tratados, reconstituídos com pinos intra-radiculares, quando submetidos à ciclagem dinâmica / Evaluation of the fracture strength of endodontically treated teeth, reconstructed with post and cores, when submitted to the dynamic loading

Freitas, Fernando Furtado Antunes de 26 November 2007 (has links)
Neste estudo, foi avaliada a resistência à fratura de dentes que, já tratados endodonticamente, foram reconstruídos proteticamente com uma coroa de liga de NiCr (Verabond II), a qual era apoiada sobre núcleos compostos por diferentes materiais, obtidos por diferentes técnicas, cimentados no remanescente radicular com o ionômero de vidro Rely X Lutting 2, o qual é acrescido de resina composta. Esses núcleos eram do tipo metálico fundido, no grupo NMF; no grupo ANATO, a resina composta Filtek Z250 (3M ESPE, St. Paul-MN, USA) constituía o núcleo, contendo um pino de fibra de vidro (Reforpost Fibra de Vidro RX, Ângelus Indústria de Produtos Odontológicos Ltda.,Londrina-PR); este mesmo tipo de pino era utilizado no grupo PFFV, sendo diretamente cimentado, sem acréscimo de resina; finalmente, no grupo PFM, um pino metálico (no 064, FKG Dentaire S. A., La Chaux-de-Fonds, Swiss) era cimentado da mesma maneira descrita para o grupo anterior. Os remanescentes radiculares eram provenientes de dentes caninos superiores humanos, distribuídos aleatoriamente, compondo assim os quatro grupos, cada um com 10 espécimes: Os espécimes, após 24 horas da cimentação, foram submetidos a esforços cíclicos, em uma Máquina Eletro-Mecânica de Fadiga, aplicados no sentido do longo eixo dental, com carga de 20 N, na freqüência de 2,0 Hz, assim perfazendo um total de 250.000 ciclos. Excetuando-se 2 corpos-de-prova cujos núcleos soltaram-se da raiz, durante a carga cíclica, todos os demais foram submetidos a uma carga de compressão, numa máquina universal de ensaios (Kratos - Dinamômetros Ltda. São Paulo-SP), regulada na velocidade de 0,5 mm/min, com a força aplicada na face palatina da coroa, num ângulo de 45º em relação ao longo eixo dental, até a ocorrência da fratura radicular. Os valores de resistência encontrados foram os seguintes, em ordem decrescente: 47,677 kgf para o grupo NMF, 34,921 kgf para o PFM, 31,354 kgf para o PFFV e, 27,172 kgf para o ANATO. A análise de variância aplicada aos valores originais apontou diferença entre os grupos estudados e um subseqüente teste de Tukey (p<0,05) permitiu verificar semelhanças entre todos eles, com diferença significante apenas entre os grupos NMF e ANATO. / In this study, was evaluated the strength of endodontically treated teeth, had been reconstructed with a crown of NiCr alloy (Verabond II), which was supported by a post and core for different materials, gotten for different techniques, cemented in the root with the glass ionomer Rely X Lutting 2, which is increased of composed resin. These diferents post and cores were of the casting metallic type, in group NMF; in group ANATO, the composed resin Filtek Z250 (3M ESPE, St. Paul-MN, USA) was the core, contend a glass fiber post (Reforpost Fibra de Vidro RX, Ângelus Indústria de Produtos Odontológicos Ltda., Londrina - PR); this exactly type of post was used in group PFFV, being directly cemented, without resin addition on the core; finally, in group PFM, a metallic post (064, FKG Dentaire S. , La Chaux-of-Fonds, Swiss) were cemented in the same way described for the previous group. All the roots were proceeding from maxillary human canines, randomly distributed, thus composing the four groups, each one with 10 specimens: The specimens, after 24 hours of the cimentation, had been submitted the cyclical efforts, in an Electromechanical Machine of Fatigue, applied in the direction of the long dental axle, with load of 20 N, in the frequency of 2 Hz, thus occuring a total of 250.000 cycles. Excepting 2 body-of-test whose post and cores had been freed of the root, during the cyclical load, all excessively had been submitted to a compression load, in a universal machine of assays (Kratos - Ltda. Dinamômetros. São Paulo - SP), regulated in the speed of 0,5 mm/min, with the force applied in the lingual face of the crown, in an angle of 45º in relation to the long dental axle, until the occurrence of the any root fracture. The joined values of resistance had been following, orderly the decreasing one: 47,677 kgf for group NMF, 34.921 kgf for the PFM, 31,354 kgf for the PFFV and, 27,172 kgf for the ANATO. The analysis of variance applied to the original values pointed difference between the studied groups and a subsequent Tukey test (p<0,05) it allowed to verify similarities between all they, with significant difference only between groups NMF and ANATO.
27

Conversor configurável analógico para informação.

REIS, Vanderson de Lima. 23 May 2018 (has links)
Submitted by Lucienne Costa (lucienneferreira@ufcg.edu.br) on 2018-05-23T00:02:18Z No. of bitstreams: 1 VANDERSON DE LIMA REIS – TESE (PPGEE) 2017.pdf: 6102324 bytes, checksum: 3f5467799d6127fee0e2bce02ef9d841 (MD5) / Made available in DSpace on 2018-05-23T00:02:18Z (GMT). No. of bitstreams: 1 VANDERSON DE LIMA REIS – TESE (PPGEE) 2017.pdf: 6102324 bytes, checksum: 3f5467799d6127fee0e2bce02ef9d841 (MD5) Previous issue date: 2017-04-20 / Capes / Nos conversores Analógicos Digitais (ADC) com frequência de conversão baseada no Teorema de Nyquist, o parâmetro básico para orientar a aquisição é a largura de banda do sinal. O tratamento da informação e a remoção da redundância são realizados após a representação digital obtida do sinal. A Amostragem Compressiva foi proposta como uma técnica de digitalização que explora a esparsidade do sinal em um determinado domínio, para capturar apenas seu conteúdo de informação, com uma taxa que pode ser menor do que a preconizada pelo Teorema de Nyquist. As arquiteturas em hardware para implementar a Amostragem Compressiva são chamadas de Conversores Analógicos para Informação (AIC). Os AIC propostos na bibliografia exploram a esparsidade do sinal em um determinado domínio, e por isso cada arquitetura é especifica para uma classe de sinais. Nesta tese propõe-se um AIC configurável, baseado em arquiteturas conhecidas, capaz de adquirir sinais de várias classes, alterando seus parâmetros de configuração. No trabalho desenvolveu-se um modelo computacional, que permite analisar o comportamento dinâmico do AIC, e dos parâmetros de hardware propostos, bem como foi feita a implementação física da arquitetura proposta. Verificou-se a adaptabilidade dessa arquitetura a partir dos resultados obtidos, pois foi possível fazer a aquisição de mais de uma classe de sinais. / In analog-to-digital converters (ADC) based on Nyquist Theorem, the basic parameter to guide acquisition is the bandwidth of the signal. The information processing and redundancy removal are performed after the digital representation obtained from the signal. Compressed Sensing was proposed as a digitalization technique that exploits the sparsity of the signal in a given domain to capture only its information content, at a rate that may be lower than that advocated by the Nyquist Theorem. The hardware architectures to implement Compressed Sensing are called Analog to Information Converters (AIC). The AICs proposed in the bibliography exploit the sparsity of the signal in a given domain, and therefore each architecture is specific for a class of signals. This thesis proposes a configurable AIC, based on known architectures, capable of acquiring signals from several classes, changing its configuration parameters. A computational model was developed to analyze the dynamic behavior of AIC and proposed hardware parameters, as well as the physical implementation of the proposed architecture. It was verified the adaptability of the proposed architecture from the obtained results, since it was possible to perform the acquisition of more than one class of signals.
28

RESISTÊNCIA À FRATURA DE DENTES COM RAÍZES FRAGILIZADAS RESTAURADOS COM DIFERENTES RETENTORES INTRARRADICULARES / FRACTURE RESISTANCE OF WEAKENED ROOTS RESTORED BY DIFFERENT POST SYSTEMS

Broch, Juliana 02 March 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Taking into account the importance of developing techniques to restore teeth with excessively flared root canals, this study aimed to evaluate the effect of mechanical cycling on the fracture resistance of teeth with weakened roots, restored with different techniques, as well as to analyze the failure modes after fracture testing. Eighty (N=80) bovine lower incisors were selected and the coronal and cervical portions were sectioned to standardize the specimens length at 15 mm. The roots were endodontically treated and prepared to 10 mm in intracanal length. The cervical portion of the root inner surface (5 mm) was enlarged (removing the intracanal dentin) using a diamond drill (KG Sorensen #4138) to produce a radicular wall with 1 mm in thickness. The specimens were embedded with acrylic resin and the periodontal ligament was simulated with a polyether material. Afterwards, the specimens were randomly allocated in 4 intracanal restoring strategies: cast post and core; double-tapered glass fiber post with cervical emerging diameter of 1.8 mm; double-tapered glass fiber post with cervical emerging diameter of 2.2 mm; anatomic posts (fiber posts relined with composite resin). Each restoring method was assessed without or with mechanical cycling, applying the protocol as followed: angle of 45º, 37ºC temperature, load of 88N, frequency of 2.2 Hz, 1.000.000 load-pulses. All of the restored teeth received metal full crown (Ni-Cr). All the specimens were submitted to fracture resistance at 45º and at a cross-head speed of 0.5 mm/min. Two-way ANOVA and Tukey showed that the root post system (p < 0.0004), the mechanical cycling (p < 0.003) and the interaction between the factors (p < 0.02) were statistically significant. The restoring methods with fiber posts did not change after mechanical cycling. Its fracture strength values were similar to that from cast post and core. The anatomic post suffered degradation with the mechanical cycling (the values reduced after aging). Concerning the mode of failure, the most failure from groups restored with cast post and core were catastrophic while the others groups showed a predominance of repairable failures. / Diante da necessidade do desenvolvimento de técnicas capazes de restaurar adequadamente raízes com condutos alargados, este trabalho visou avaliar o efeito da ciclagem mecânica sobre a resistência à fratura de dentes com raízes fragilizadas e restaurados com diferentes retentores intrarradiculares, bem como analisar o padrão de falha destes dentes quando submetidos à carga compressiva. Foram utilizados para este estudo 80 incisivos inferiores bovinos, cujas raízes foram seccionadas em 15 mm de comprimento, tratadas endodonticamente e preparadas até 10 mm de profundidade. Os 5 mm cervicais dos canais radiculares destas raízes foram fragilizados com uma ponta diamantada (4138), de modo a gerar uma espessura de parede radicular de 1 mm. As raízes foram incluídas em resina acrílica autopolimerizável e o ligamento periodontal foi simulado com material elastomérico (poliéter). Após, as raízes foram distribuídas aleatoriamente em quatro sistemas de retentores intrarradiculares: núcleo metálico fundido, pino de fibra de vidro (pinos de dupla conicidade, 1,8 mm de diâmetro cervical), pino de fibra de vidro especial (pinos de dupla conicidade, 2,2 mm de diâmetro cervical) e pino anatômico. Cada um desses sistemas de retentores foi avaliado com e sem ciclagem mecânica, sendo o protocolo de ciclagem o seguinte: angulação de 45°, temperatura de 37°C, força de 88N, freqüência de 2,2 Hz, totalizando 1 milhão de ciclos; durante a mesma os espécimes dos grupos sem ciclagem mecânica ficaram armazenados em água destilada. Em todos os grupos, foram cimentadas coroas totais metálicas de Níquel-Cromo sobre o núcleo. Os corpos de prova de todos os grupos foram submetidos ao teste de resistência à compressão em uma inclinação de 45° e à velocidade de 0,5 mm/mim até ocorrer a falha. A análise de Variância seguida de Tukey mostrou que o tipo de retentor intrarradicular (p < 0,0004), a ciclagem mecânica (p < 0,003) e a interação entre ambos (p < 0,02), foram estatisticamente significantes. Os pinos de fibra de vidro mantiveram-se estáveis após a ciclagem mecânica, com valores de resistência à fratura similares aos núcleos metálicos fundidos. Somente pinos anatômicos sofreram degradação com a ciclagem, reduzindo significativamente os valores de resistência à fratura. Em relação ao padrão de falha, foram fraturas predominantemente irreversíveis nos grupos reconstruídos com núcleo metálico fundido, e nos demais, reversíveis.
29

Aumento da vida em fadiga por meio do processo de roleteamento profundo para geração de tensão residual compressiva

Ciro Leandro Oliveira 10 April 2012 (has links)
Este trabalho comprovou a eficácia do processo de roleteamento profundo no aumento da vida em fadiga em eixos submetidos ao ensaio de fadiga sob tensão axial. Uma pesquisa bibliográfica extensa foi realizada para o entendimento do comportamento físico do fenômeno encruamento, onde esta pesquisa abrangeu a metalurgia, plasticidade e elasticidade dos materiais, processos de geração de tensão residual e ensaios destrutivos e não destrutivos para obtenção de valores reais. O corpo de prova utilizado, em relação ao corpo de prova padronizado, foi modificado para simular o efeito do entalhe como concentrador de tensões. Corpos de prova sem o tratamento mecânico de roleteamento e corpos de prova com o tratamento foram submetidas ao ensaio de fadiga de tensão axial e de difração de raios-X, a fim de comparar o ganho do processo de roleteamento profundo. Com os resultados dos ensaios de fadiga foi possível obter as curvas Wöhler, "S-N", pertinentes aos dois diferentes grupos de amostras: com e sem o tratamento de roleteamento profundo. Simulações pelo Método dos Elementos Finitos foram usadas também para tentar reproduzir os efeitos da tensão residual compressiva sobre a vida em fadiga assim como os resultados obtidos nos ensaios de fadiga e difração de raios-X. / This project has proved the effectiveness of the deep rolling process in the increasing of fatigue life on shafts submitted to axial stress fatigue test. A deep literature research has done for understanding of the physic behavior of the hardening phenomenon, where this research included metallurgy, plasticity and elasticity of materials, generation of residual stress processes and destructive and nondestructive tests to obtain the real values. The specimen used, comparing to the standard one, had been changed to simulate the notch effect as stress concentrator. Specimen with and without rolling mechanical treatment have submitted to axial stress fatigue test and X-rays diffraction test, to compare the gain of the deep rolling process. With the results of fatigue tests, became possible to obtain the Wöhler curves, "S-N", from each different groups of specimens: with and without the deep rolling treatment. Simulations by Finite Element Method have also used to try reproducing the compressive residual stress effects under the fatigue life, like the obtained results from fatigue and X-rays diffraction tests.
30

Desenvolvimento de técnicas para caracterização de concreto seco utilizado na fabricação de peças de concreto para pavimentação intertravada. / Development of techniques to characterize dry concrete used on the precast paving blocks for interlocking pavement.

Mariana Lobo Marchioni 03 October 2012 (has links)
O concreto seco, também chamado de concreto sem abatimento (no-slump) é utilizado na produção de artefatos de cimento, como por exemplo em peças de concreto para pavimentação, blocos para alvenaria e tubos de concreto e ainda como camada de subbase de pavimentos com a técnica de concreto compactado a rolo. A técnica de conformar concretos com reduzido teor de umidade através de equipamentos que aplicam simultaneamente compressão e vibração é amplamente utilizada na produção de artefatos de concreto, como as peças de concreto para pavimentação intertravada. Para as peças de concreto o desafio é ainda maior, pois as especificações de resistência característica à compressão podem chegar a 50 MPa. A principal característica do concreto seco é o baixo teor de água e elevada coesão, necessitando de energia de compactação e vibração para a eliminação de vazios e o concreto assumir a forma desejada. Esta técnica permite a desfôrma imediata, que garante elevada produtividade e consequente diminuição dos custos de produção. Já a compactação permite obter componentes de concreto com menor consumo de cimento se comparados ao concreto plástico. Diferentemente de toda literatura e metodologias de dosagem encontradas para o concreto plástico, o concreto seco encontra barreiras técnicas para a aplicação de metodologias que otimizem sua dosagem, em formulações empíricas que não levam em conta de forma adequada as características dos agregados, características estas diretamente ligadas à compacidade das peças, que por sua vez tem grande influência nas características do produto final. Além disto, há poucos estudos do comportamento reológico do concreto seco, que influenciam a fluidez e coesão da do concreto e que irão determinar a produtividade e qualidade da produção. Dessa forma, neste trabalho é apresentado uma metodologia para caracterização do concreto seco nos estados fresco e endurecido que permite o desenvolvimento sistemático de formulações com maior facilidade de compactação e que também resulte na melhoria do desempenho das peças e diminuindo a necessidade de testes em escala real. O método se baseia em produzir em laboratório um corpo de prova que reproduz as condições de moldagem de uma vibroprensa, eliminando-se a variável da vibração e padronizando as condições de compressão. Nos corpos-de-prova são avaliadas características nos estados fresco e endurecido, além de aspectos do comportamento reológico do concreto, através de técnicas de reologia compressiva. Para aferir a metodologia foram utilizadas amostras de referência produzidas em uma fábrica de peças de concreto. Com a metodologia proposta, foi possível atingir 90% da resistência mecânica das peças produzidas em uma vibroprensa de alta compactação. Sendo assim esta metodologia poderá ser utilizada em estudos de dosagem de concreto seco, portanto o trabalho desenvolvido é indicado na utilização de dosagens de concreto seco, obtendo-se maior ecoeficiência, a medida que otimiza o consumo de cimento da mistura e facilita o estudo de dosagem de materiais alternativos em substituição aos agregados convencionais. / The dry concrete, also known as earth moist concrete or no-slump concrete, is most used to manufacture precast concrete products, as paving blocks, masonry blocks and concrete tubes, and also in rolled compacted concrete pavement. Its most important property is the low water content, and it requires mechanical equipment for its compactation. Paving blocks are normally manufactured using vibrocompression equipment, which at the same time applies both compaction and vibration resulting in paving blocks with high durability and mechanical resistance. Even though this technique is highly used it still lacks studies on some important steps of the manufacturing process. The mix design techniques are mostly empirical and dont deeply consider the aggregate characteristics, that are connected with its compacity and, by that, the characteristics of the paving block. Also, there are only a few studies of the rheology characteristics of dry concrete, which relates with de manufacturing process and the easiness that the mix is compacted. So, the object of this study is to develop a dry concrete characterization methodology that allows the systematic development of mix designs that are easily compacted and also improves the performance of the paving blocks.

Page generated in 0.069 seconds