• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 21
  • Tagged with
  • 21
  • 21
  • 18
  • 16
  • 15
  • 14
  • 14
  • 7
  • 6
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Análise fotoelástica das tensões geradas por diferentes planejamentos de próteses parciais fixas cimentadas sobre implantes cone morse / Photoelastic analyses of stress generated by different designs of cemented-retained fixed partial denture on morse taper implants

Menani, Luiz Ricardo 28 August 2009 (has links)
O presente trabalho se propôs a avaliar, por meio de análise fotoelástica, o comportamento biomecânico de próteses parciais fixas cimentadas sobre implantes cone Morse (Titamax CM 4.0x11mm, Neodent) com coroas isoladas ou unidas, simulando a reabilitação de áreas posteriores com e sem a presença de elemento dental distal aos implantes, e ainda variando o tipo de material de recobrimento estético empregado na restauração protética (cerâmica ou resina), quando sobre estas próteses foram aplicadas diferentes tipos de cargas estáticas. Foi confeccionado um modelo fotoelástico simulando um espaço protético intercalado, com ausência do segundo pré-molar e primeiro molar, reabilitado por meio de quatro tipos de coroas cimentadas sobre dois implantes adjacentes: UC - coroas unidas com recobrimento estético em cerâmica; IC - coroas individuais com recobrimento estético em cerâmica; UR - coroas unidas com recobrimento estético em resina; IR - coroas individuais com recobrimento estético em resina. Análise fotoelástica qualitativa foi realizada sob diferentes condições de aplicação de carga na superfície oclusal das coroas: oclusal distribuída (10kgf), puntiforme simultânea (10kgf), puntiforme alternada no molar e no pré-molar (5kgf). A primeira análise foi feita na presença de contato proximal efetivo entre as próteses e o dente a distal dos implantes. A segunda análise foi realizada após a eliminação da coroa do dente distal no modelo fotoelástico. Registros fotográficos foram obtidos de cada situação de análise, a fim de facilitar a observação e comparação do padrão de distribuição das franjas isocromáticas em torno dos implantes. De acordo com os resultados obtidos, pode-se concluir que as restaurações cimentadas provocaram tensões no modelo fotoelástico mesmo quando da ausência de cargas oclusais. A ferulização das restaurações em cerâmica promoveu melhores distribuições das tensões isocromáticas em torno dos implantes. A presença do pilar distal com ponto de contato efetivo e ajustado nas restaurações modificou a distribuição das tensões isocromáticas, sendo que os estresses gerados pelas cargas oclusais foram também dissipados pelas réplicas dos dentes e transmitidos ao sistema fotoelástico. Ressalta-se a importância da obtenção de oclusão bem ajustada e equilibrada, para que haja adequada distribuição de forças aos implantes e osso de suporte, garantindo maior longevidade e previsibilidade de sucesso. / The purpose of this study was to evaluate the biomechanical behavior of fixed prostheses cemented over morse taper implants simulating a posterior rehabilitation with or without distal teeth to the implants, by use of a photoelastic stress analysis technique. Non-segmented or segmented ceramic or resin crowns were constructed over the implants and were evaluated when different static loads were applied. A photoelastic model simulating a prosthetic space without the second premolar and the first molar was done. The edentulous space was rehabilitated with crowns cemented over morse taper implants: UC = non-segmented ceramic crowns; IC = segmented ceramic crowns; UR = non-segmented resin crowns, and IR = segmented resin crowns. Qualitative photoelastic analysis was done with different loads conditions at the occlusal surface of the crowns: distributed occlusal (10kgf), punctiform over the first molar and second premolar simultaneously (5kgf), and punctiform over the first molar or second premolar alternatively (5kgf). The first analysis was done when the proximal contact was present between the crowns and the distal teeth to implants. The second was done after the remotion of the distal teeth at the photoelastic model. The resulting stress in all areas of the model was monitored and recorded photographically in the field of a circular polariscope. The fringe pattern findings were collected for the loadings subjected to each condition and loading position. According to the results obtained it would be concluded that the cemented restorations promoted stress even without occlusal loads. The ferulization of the ceramic restorations promoted a better stress distribution around the implants. The presence of the distal teeth with an effective and adjusted contact point modified the stress distribution. Stresses generated by occlusal loads was distributed by the replicas of the teeth and transmitted to the photoelastic system. The adjusted and balanced occlusion is important to the correct load distribution to the implants and support bone, which assure a better prognostic to the rehabilitation.
12

Análise fotoelástica das tensões geradas por diferentes planejamentos de próteses parciais fixas cimentadas sobre implantes cone morse / Photoelastic analyses of stress generated by different designs of cemented-retained fixed partial denture on morse taper implants

Luiz Ricardo Menani 28 August 2009 (has links)
O presente trabalho se propôs a avaliar, por meio de análise fotoelástica, o comportamento biomecânico de próteses parciais fixas cimentadas sobre implantes cone Morse (Titamax CM 4.0x11mm, Neodent) com coroas isoladas ou unidas, simulando a reabilitação de áreas posteriores com e sem a presença de elemento dental distal aos implantes, e ainda variando o tipo de material de recobrimento estético empregado na restauração protética (cerâmica ou resina), quando sobre estas próteses foram aplicadas diferentes tipos de cargas estáticas. Foi confeccionado um modelo fotoelástico simulando um espaço protético intercalado, com ausência do segundo pré-molar e primeiro molar, reabilitado por meio de quatro tipos de coroas cimentadas sobre dois implantes adjacentes: UC - coroas unidas com recobrimento estético em cerâmica; IC - coroas individuais com recobrimento estético em cerâmica; UR - coroas unidas com recobrimento estético em resina; IR - coroas individuais com recobrimento estético em resina. Análise fotoelástica qualitativa foi realizada sob diferentes condições de aplicação de carga na superfície oclusal das coroas: oclusal distribuída (10kgf), puntiforme simultânea (10kgf), puntiforme alternada no molar e no pré-molar (5kgf). A primeira análise foi feita na presença de contato proximal efetivo entre as próteses e o dente a distal dos implantes. A segunda análise foi realizada após a eliminação da coroa do dente distal no modelo fotoelástico. Registros fotográficos foram obtidos de cada situação de análise, a fim de facilitar a observação e comparação do padrão de distribuição das franjas isocromáticas em torno dos implantes. De acordo com os resultados obtidos, pode-se concluir que as restaurações cimentadas provocaram tensões no modelo fotoelástico mesmo quando da ausência de cargas oclusais. A ferulização das restaurações em cerâmica promoveu melhores distribuições das tensões isocromáticas em torno dos implantes. A presença do pilar distal com ponto de contato efetivo e ajustado nas restaurações modificou a distribuição das tensões isocromáticas, sendo que os estresses gerados pelas cargas oclusais foram também dissipados pelas réplicas dos dentes e transmitidos ao sistema fotoelástico. Ressalta-se a importância da obtenção de oclusão bem ajustada e equilibrada, para que haja adequada distribuição de forças aos implantes e osso de suporte, garantindo maior longevidade e previsibilidade de sucesso. / The purpose of this study was to evaluate the biomechanical behavior of fixed prostheses cemented over morse taper implants simulating a posterior rehabilitation with or without distal teeth to the implants, by use of a photoelastic stress analysis technique. Non-segmented or segmented ceramic or resin crowns were constructed over the implants and were evaluated when different static loads were applied. A photoelastic model simulating a prosthetic space without the second premolar and the first molar was done. The edentulous space was rehabilitated with crowns cemented over morse taper implants: UC = non-segmented ceramic crowns; IC = segmented ceramic crowns; UR = non-segmented resin crowns, and IR = segmented resin crowns. Qualitative photoelastic analysis was done with different loads conditions at the occlusal surface of the crowns: distributed occlusal (10kgf), punctiform over the first molar and second premolar simultaneously (5kgf), and punctiform over the first molar or second premolar alternatively (5kgf). The first analysis was done when the proximal contact was present between the crowns and the distal teeth to implants. The second was done after the remotion of the distal teeth at the photoelastic model. The resulting stress in all areas of the model was monitored and recorded photographically in the field of a circular polariscope. The fringe pattern findings were collected for the loadings subjected to each condition and loading position. According to the results obtained it would be concluded that the cemented restorations promoted stress even without occlusal loads. The ferulization of the ceramic restorations promoted a better stress distribution around the implants. The presence of the distal teeth with an effective and adjusted contact point modified the stress distribution. Stresses generated by occlusal loads was distributed by the replicas of the teeth and transmitted to the photoelastic system. The adjusted and balanced occlusion is important to the correct load distribution to the implants and support bone, which assure a better prognostic to the rehabilitation.
13

Avaliação in vitro do colar de implantes cone Morse de diferentes diâmetros sob cargas cêntrica e excêntrica: estudo por meio da Interferometria Eletrônica por Padrões de Speckle / In vitro evaluation of the collar of Morse taper dental implants with different diameters under centric and eccentric loads: an electronic speckle pattern interferometry study

Sergio Rodrigues Sizo 15 September 2011 (has links)
Cargas oclusais excessivas podem promover tensões exageradas às estruturas de implantes/pilares/próteses, resultando em deformação, desadaptação ou mesmo fratura dos componentes e do próprio implante. Além disso, tais sobrecargas podem gerar necrose por compressão e perda óssea peri-implantar e, ainda, a ocorrência de microdeslocamentos na interface de conexão implante-pilar (I-P) ocasionando a formação de fendas propícias à colonização bacteriana, o que pode levar ao desenvolvimento de peri-implantite, contribuindo para o insucesso do conjunto. O presente estudo objetivou avaliar, por meio de uma técnica já amplamente utilizada na Engenharia e na Física a Interferometria Eletrônica por Padrões de Speckle (ESPI) as deformações a nível do colar de implantes com conexão cônica interna (cone Morse) de diferentes diâmetros (Kopp 4,3/5,5 mm e Neodent 3,5/5,0 mm), sob dois tipos (cêntrica e excêntrica) e intensidades (50 N e 100 N) de cargas, similares as quais os implantes ficam expostos durante a função mastigatória. Testou-se a hipótese de que a deformação do colar do implante seria inversamente proporcional ao diâmetro do implante. Além disso, discutiu-se vantagens e limitações da técnica ESPI frente a outros métodos comumente utilizados na avaliação de tensões. As maiores deformações foram sempre associadas às cargas excêntricas, com exceção do G1-Kopp. A maior deformação ocorreu no G1-Neodent sob carga excêntrica de 100 N e a menor, no G2-Neodent sob carga cêntrica de 50 N. A técnica ESPI mostrou-se altamente sensível e reprodutível para avaliar deformações a nivel do colar de implantes sendo possível confirmar a hipótese inicial, visto que a maior deformação esteve sempre associada aos implantes de menor diâmetro, em ambos os sistemas de implante pesquisados. / Occlusal overloading may promote excessive stresses to the implants/abutments/prosthesis, resulting in deformation, misfit or fracture of the components, until the implants. Futhermore, strains of the implant-abutment connection can cause the formation of microgaps propitious to bacterial colonization, which leads to the development of peri-implant sites, leading to the failure of the rehabilitation. This study aimed to evaluate, by a technique widely used in the engineering and physics Electronic Speckle Pattern Interferometry (ESPI) the strains related to the implant collar with internal tappered connection (Morse taper) with different diameters (Kopp 4.3/5.5 mm and Neodent 3,5/5,0 mm), under two types (centric and eccentric) and intensities (50 N and 100 N) of loads, similar which implants are exposed during masticatory function. We tested the hypothesis that the strains of the implants collar would be inversely proportional to the diameter of the implant. In addition, the survey discussed the advantages and limitations of the ESPI technique over other methods commonly used to assess strains. The largest strain was always associated with eccentric loads, except for G1-Kopp. The largest strain occurred in the G1-Neodent under the eccentric loads of 100 N and the lowest in the G2-Neodent under the centric loads of 50 N. The ESPI technique was a highly sensitive and reproducible to evaluate the strains at the level of the collar of implants being possible to confirm the initial hypothesis, since most strains was always associated with narrower-diameter implants in both implant systems studied.
14

Análise fotoelástica de implantes cone-Morse posicionados ao nível e infraósseo na região posterior / Photoelastic analysis of morse taper implants positioned equicrestal and subcrestal in the posterior area

Suleima do Vale Alves 06 December 2013 (has links)
O meio cientifico na área odontológica está sempre procurando materiais e tratamentos que de maior previsibilidade e sucesso em longo prazo. Este trabalho procurou avaliar, por meio de análise fotoelástica, o comportamento das tensões geradas de cargas exercidas em prótese sobre implante posteriores adjacente ou não a réplicas de dentes. Todos os implantes cone-Morse utilizados eram da marca ANKYLOS®, da Dentsply, de 3,5 x 9,5 mm. Para a confecção das réplicas dos dentes utilizou-se resina Luxatemp e foram confeccionadas coroas unitárias de cerâmica. Foram confeccionados três modelos contendo dente-implante-dente, entretanto em cada modelo o implante apresentava-se em uma altura diferente em relação à crista marginal (nível, 1,5 mm e 3,0 mm subcristal). Foram fabricados mais três modelos com as mesmas características, mas com ausência do segundo molar e três modelos com apenas o implante em posição. Os modelo com três elementos com carregamento axial (oclusão balanceada) apresentaram tensões com direção para a região apical conforme o implante apresentava-se mais subcristal; os modelo com dois elementos com carregamento axial (oclusão balanceada), modelos com implantes unitários com carregamento axial (pontual central), modelos com implantes unitários com carregamento axial (pontual distal) e os modelos com implante unitário com carregamento não axial (vestibular-lingual) apresentaram também o mesmo comportamento em relação ao direcionamento das tensões para a região apical. A diferenciação entre os modelos foi observada apenas em relação a intensidade das tensões de algumas regiões. Desta maneira pode-se concluir que quanto mais subcristal o implante se encontra menor é a tensão na região cristal, independentemente da presença ou não de dentes adjacentes, e a presença de dentes adjacentes à prótese sobre implante influência na intensidade de tensão gerada nos implantes, mas não há influência no direcionamento dessas tensões. / The scientific environment in dentistry is always searching for materials and treatments more predictable and which presented a long-term success. The aim of this study was to evaluate by photoelastic analysis, the stresses behavior generated by loads applied to the implant prosthesis posterior between or not to teeth. All implants Morse taper used (Ankylos®,Dentsply Implants) with 3.5mm x 9.5mm. The teeth were made by Luxatemp resin and ceramic crowns were fabricated. Three models containing tooth - implant - tooth were built, meanwhile each model had the implant in different height from the marginal bone crestal level (equicrestal, 1.5mm and 3.0 mm the crest). Subsequently, other three models were made with the same characteristics, but without the second molar and another three models just with the implant in position. Models witch three elements with axial loading (balanced occlusion) had tensions with direction to the apical region as the implant had become more subcristal , models with two elements with axial loading ( balanced occlusion ) , models with single implants with axial loading ( central point ) , models with single implants with axial loading (distal point ) and models with single implant with no axial loading (buccal - lingual) also showed the same behavior with respect to the direction of the stresses to the apical region. The differentiation between the models was only observed for the intensity of the stresses in some regions. Thus it can be concluded that the more the implant is subcristal lower the tension in the crystal region regardless of the presence or absence of adjacent teeth, and the presence of adjacent teeth prosthesis on the implant influence on the stress intensity generated in the implants but no influence on the direction of these stresses.
15

Análise fotoelástica das tensões geradas por diferentes planejamentos de próteses parciais fixas parafusadas sobre implantes cone morse / Photoelastic analyses of stress generated by different designs of screw-retained fixed partial denture on morse taper implants

Torres, Érica Miranda de 01 July 2008 (has links)
A restauração protética deve receber e transmitir cargas funcionais aos implantes de forma controlada, a fim de minimizar a ocorrência de falhas mecânicas e biológicas. A concentração de tensões inadequadas na interface osso-implante pode provocar reabsorção óssea em torno dos implantes em níveis superiores aos considerados clinicamente aceitáveis. Não existe consenso na literatura quanto ao melhor planejamento protético para reabilitações parciais com múltiplos implantes adjacentes, a fim de minimizar as tensões geradas na interface osso-implante. A fotoelasticidade é uma técnica experimental para análise de tensões, bastante empregada devido à sua relativa simplicidade e confiabilidade quanto à correspondência clínica dos achados observados. O presente trabalho se propôs a avaliar, por meio de análise fotoelástica, o comportamento biomecânico de próteses parciais fixas parafusadas sobre implantes cone morse com coroas isoladas ou unidas, simulando a reabilitação de áreas posteriores com e sem a presença de elemento dental distal aos implantes, e ainda variando o tipo de material de recobrimento estético empregado na restauração protética (cerâmica ou resina), quando sobre estas próteses foram aplicadas diferentes tipos de cargas estáticas. Para tanto, foi confeccionado um modelo fotoelástico simulando um espaço protético intercalado, com ausência do segundo prémolar e primeiro molar, reabilitado por meio de quatro tipos de coroas parafusadas sobre dois implantes cone morse (Neodent) adjacentes: UC - coroas unidas com recobrimento estético em cerâmica; IC - coroas isoladas com recobrimento estético em cerâmica; UR - coroas unidas com recobrimento estético em resina; IR - coroas isoladas com recobrimento estético em resina. A adaptação marginal das coroas foi avaliada pela leitura dos desajustes verticais na interface coroa/pilar em microscópio ótico. Análise fotoelástica qualitativa foi realizada sob diferentes condições de aplicação de carga na superfície oslusal das coroas: oclusal distribuída (1kgf), puntiforme simultânea (1kgf), puntiforme alternada no molar e no pré-molar (0,5kgf). A primeira análise foi feita na presença de contato proximal efetivo entre as próteses e o dente a distal dos implantes. A segunda análise foi realizada após eliminar a coroa do dente distal no modelo fotoelástico. Registros fotográficos foram obtidos de cada situação de interesse para análise, a fim de facilitar a observação e comparação do padrão de distribuição das franjas isocromáticas em torno dos implantes. De acordo com os resultados obtidos pode-se concluir que a ferulização das coroas promoveu melhor distribuição de tensões em torno dos implantes. As restaurações metalocerâmicas resultaram em menor magnitude e concentração de tensões em torno dos implantes quando comparadas às restaurações metaloplásticas. A presença de um dente com ponto de contato efetivo na distal das coroas não modificou as tensões resultantes em torno dos implantes, mas este dente participou da distribuição de tensões para o modelo fotoelástico. A ausência de uma oclusão bem ajustada e distribuída sobre as restaurações protéticas pode provocar sobrecarga nos implantes. / Prosthetic restoration should suffer and apply functional loads over implants in a controlled way with the aim to reduce the occurrence of mechanical and biological failures. The concentration of inadequate stress on the implant-bone interface may cause bone resorption around implants at levels above those considered clinically acceptable. There is no consensus in the literature about the best prosthetic plan for partial rehabilitation with multiple adjacent implants, with the aim to reduce the stress generates over the implantbone interface. Photoelasticity is an experimental technique used to analyzes stress and is highly used due to its relative simplicity and reliability in terms of the clinical agreement of the findings. The purpose of the present study was to assess, using photoelastic analysis, the biomechanical behavior of screwretained fixed partial dentures on morse taper implants with individual or connected crowns, simulating the rehabilitation of posterior areas with or without the presence of a dental element distal to the implants. Furthermore, the analyses considered different esthetic materials used in prosthetic restorations (ceramic or resin), and different static loads were applied over the prostheses. To do this, a photoelastic model was fabricated simulating the missing of the second pre-molar and the first molar. The model was rehabilitated through four types of screw-retained crowns over two adjacent morse taper implants (Neodent): CC connected crowns with ceramic esthetic overlay; IC individual crowns with ceramic esthetic overlay; CR connected crowns with resin esthetic overlay; - IR - individual crowns with resin esthetic overlay. The crowns marginal fit was assessed by reading the vertical misfits on the crownabutment interface using an optic microscope. The qualitative photoelastic analysis was performed under the application of different loads on the crowns occlusal surface: distributed occlusal (1kgf), simultaneous punctiform (1kgf), alternate punctiform over the molar and pre-molar (0.5 kgf). The first analysis was done with an effective proximal contact between the prostheses and the distal tooth. The second analysis was performed after eliminating the crown of the distal tooth in the photoelastic model. Photoelastic records were obtained in each situation that was of any interest to the analysis, with the aim to make it easy to observe and compare the distribution standard of the isochromatic fringes around the implants. According to the obtained results, it is concluded that crown splint promoted better stress distribution around the implants. The metallo-ceramic restorations resulted in less magnitude and stress concentration around the implants compared to metaloplastic restorations. The presence of one tooth with an effective contact point on the crown distal did not change the resulting stress around the implants, but that tooth took part in the stress distribution for the photoelastic model. A bad distributed occlusion over the prosthetic restorations can cause overload on the implants.
16

Estudo biomecânico da conexão implante/pilar protético em implantes do sistema cone morse / Biomechanical study of the implant/abutment connection in implants with internal tapered connectios

Coppedê, Abílio Ricciardi 19 December 2007 (has links)
Conexões em cone morse foram desenvolvidas para melhorar as propriedades biomecânicas e reduzir os problemas mecânicos encontrados nos sistemas de hexágono externo e interno. Este trabalho apresenta os resultados de dois estudos que investigaram as propriedades biomecânicas da conexão implante/pilar protético em implantes do sistema cone morse. A proposta do primeiro estudo foi avaliar o efeito do carregamento mecânico na perda de torque de pilares protéticos do sistema cone morse, e o efeito de ciclos sucessivos de inserção/remoção no torque de remoção destes pilares. 69 implantes cônicos foram utilizados. Os implantes e pilares foram divididos em 4 grupos: grupos 1 e 3 receberam pilares sólidos, e os grupos 2 e 4(a,b) receberam os pilares com parafuso trespassante. Nos grupos 1 e 2 os torques de instalação foram medidos, os pilares foram removidos, e os torques de remoção foram medidos; dez ciclos de inserção/remoção foram realizados para cada conjunto implante/pilar. Nos grupos 3 e 4(a,b) os pilares foram instalados e carregados mecanicamente; os pilares foram removidos e os torques de remoção foram medidos; dez ciclos de inserção/carregamento mecânico/remoção foram realizados para cada conjunto implante/pilar. Os dados foram analizados com o teste de Student-Newman-Keuls, com um nível de significância de p &le; 0,05%. A perda de torque foi maior nos grupos 4a e 2 (acima de 30%); seguidos pelo grupo 1 (10,5%); grupo 3 (5,4%); e grupo 4b (39% de ganho de torque). Todos os resultados foram significativamente diferentes. A comparação do número de ciclos mostrou que, com o aumento do número de ciclos de inserção/remoção, houve uma tendência de aumento na perda de torque, para todos os tipos de pilares e grupos. Concluiu-se que o carregamento mecânico aumentou o torque de remoção dos pilares carregados em comparação a pilares não-carregados, e que os valores dos torques de remoção decaíram conforme o número de ciclos de inserção/remoção aumentou. O objetivo do segundo estudo foi verificar se as diferenças estruturais entre os sistemas de implantes com conexão em hexágono internos e em cone morse influenciam sua resistência à fratura. Vinte implantes cônicos com dimensões de 4,4mm de diâmetro por 13mm de comprimento foram utilizados: 10 com conexão em hexágono interno (HI) e 10 com conexão em cone morse (CM) de 11,5&deg;. Vinte pilares foram utilizados, 10 para os implantes HI (com um parafuso trespassante de fixação), e 10 para os implantes CM (sólidos). Os testes foram realizados em uma máquina universal de ensaios, com uma célula de carga de 500 kgf, deslocamento de 1mm/min, numa inclinação de 45&deg; a força máxima de deformação (FMD) e a força de fratura (FF) foram analisadas. As informações coletadas foram analizadas com um teste paramétrico (teste \"t\" de Student, p &le; 0,05). A média da FMD para os implantes CM [90.58(6.72)kgf] foi estatisticamente superior à média da FMD para os implantes HI [83.73(4.94)kgf] (p=0.0182). A média da FF para os implantes HI foi 79.86(4.77)kgf. Nenhum dos implantes CM fraturou. Por meio de microscopia óptica, verificou-se que as fraturas nos implantes HI sempre ocorreram no parafuso de fixação. Embora os implantes CM não tenham fraturado, eles sofreram deformações permanentes em sua plataforma e no pilar protético. É possível concluir que o desenho sólido dos pilares CM proporciona maior resistência à deformação e à fratura em comparação aos pilares HI. / Internal tapered connections were developed to improve biomechanical properties and to reduce mechanical problems found in external and internal hex implants. This work presents the results of two studies that investigated the biomechanical properties of the implant/abutment connection in implants with internal tapered connections. The purpose of the first study was to evaluate the effect of mechanical loading on the torque loss of abutments with internal tapered connections, and the effect of repeated torque cycles on the removal torque of these abutments. 68 conical implants and two abutment types were used. The implants and abutments were divided into 4 groups: groups 1 and 3 received the solid abutments, groups 2 and 4(a,b) received the trespassing screw abutments. In groups 1 and 2 installation torques of the abutments were measured, the abutments were uninstalled, and removal torques were measured; ten insertion/removal cycles were performed for each implant/abutment assembly. In groups 3 and 4(a,b) the abutments were installed, mechanically loaded, uninstalled, and removal torques were measured; ten insertion/mechanical loading/removal cycles were performed for each implant/abutment assembly. Data were analyzed with the Student-Newman-Keuls test, with a significance level of p &le; 0.05. Torque loss was greater in groups 4a and 2 (over 30%), followed by group 1 (10.5%), group 3 (5.4%) and group 4b (39% torque gain). All results were significantly different. The comparison of the number of cycles showed that, as the insertion/removal cycles increased, removal torques tended to be lower, for all abutment types and groups. It was concluded that mechanical loading increased loosening torque of loaded abutments in comparison to unloaded abutments, and removal torque values decrease as the number of insertion/removal cycles increase. The objective of the second study was to verify if the differences in the design of the internal hex and the internal tapered connection implant systems influence their fracture resistance. Twenty tapered implants with dimensions of 4.3mm X 13mm were utilized: 10 with an internal hex (IH) connection and 10 with an 11.5&deg; conical tapered (CT) connection. Twenty abutments were utilized, 10 for the IH implants (with a trespassing fixation screw), and 10 for the CT implants (solid). The tests were carried out in a universal testing machine, with a 500kgf load cell, 1mm/min dislocation, and 45 degrees angulation. The maximum deformation force (MDF) and the fracture force (FF) were analyzed. The collected data were analyzed with a parametric test (Student\'s t, p<.05). The average MDF for the CT implants [90.58(6.72)kgf] was statistically higher than the average MDF for the IH implants [83.73(4.94)kgf] (p=0.0182). The average FF for the IH implants was 79.86(4.77)kgf. None of the CT implants fractured. By means of optical micrography, it was verified that the fractures in the IH implants occurred always in the fixation screw. Although the CT implants did not fracture, they showed permanent deformations in the abutment and in the platform. It is possible to conclude that the solid design of the CT abutments provides greater resistance to deformation and fracture when compared to the IH abutments.
17

Estudo mecânico da conexão implante/abutment utilizando parafusos convencionais e parafusos experimentais cone morse / Mechanical study of the implant/abutment connection using conventional screws and experimental conical screws

Coppedê, Abílio Ricciardi 15 July 2011 (has links)
A proposta deste estudo foi avaliar o comportamento mecânico de dois designs de conexão implante/abutment; hexágono externo e triângulo interno, utilizando parafusos convencionais e parafusos experimentais cone morse. O estudo foi dividido em duas fases: na primeira, foi avaliado o efeito do carregamento mecânico na perda de torque dos parafusos. 40 implantes foram utilizados. Os implantes e abutments foram divididos em 4 grupos: Grupo 1: hexágono externo/parafuso convencional (HE); Grupo 2: triângulo interno/parafuso convencional (TI); Grupo 3: hexágono externo/parafuso cone morse (HECM); Grupo 4: triângulo interno/parafuso cone morse (TICM). Os abutments foram instalados em seus respectivos implantes com torque de aperto de 32Ncm; após intervalo de 10 minutos, foram medidos os valores dos torques de desaperto. Os abutments foram instalados novamente com torque de 32Ncm, e após 10 minutos foram carregados mecanicamente, simulando 1 ano de função oral normal; após o carregamento, os torques de desaperto dos parafusos foram medidos novamente. Os dados foram analisados com o teste one-way ANOVA, com nível de significância de p&le;0,05%. Análises por microscopia óptica foram realizadas antes e após os ensaios. Na segunda fase, foi avaliada a resistência à flexão dos conjuntos implante/abutment. Os mesmos 40 conjuntos foram utilizados. Os testes foram realizados em máquina universal de ensaios, com célula de carga de 500 kgf, deslocamento de 1mm/min, e inclinação de 45&deg;. A força máxima de flexão (FMF) e a força de ruptura (FR) foram determinadas. As informações coletadas foram analisadas com o teste one-way ANOVA, para p&le;0,05. Análises por microscopia óptica foram realizadas para estudo dos componentes após os ensaios de resistência flexural. Os resultados sugeriram que houve diferença significante (p=0,000) na pré-carga residual antes e após carregamento mecânico entre os dois tipos de parafuso: os parafusos cone morse apresentaram torques de desaperto significativamente superiores aos apresentados pelos parafusos planos convencionais. Houve diferença significante nos resultados da FMF obtidos pelos parafusos planos convencionais e pelos parafusos cone morse (p=0,011), sendo que os conjuntos implante/abutment com parafusos cone morse apresentaram maior resistência à flexão. Para os resultados da FR houve influência significante do tipo de conexão (p=0,019), com melhores resultados para a conexão triângulo interno. Considerando as limitações deste estudo, concluiu-se que os parafusos cone morse apresentaram maiores torques de desaperto em comparação aos parafusos planos convencionais; que o design da conexão protética não teve influência significante sobre o torque de desaperto dos parafusos; que os parafusos cone morse obtiveram maiores valores de resistência à flexão, e que a conexão em triângulo interno obteve maiores valores para a força de ruptura. / The purpose of this study was to evaluate the mechanical behavior of two implant/abutment connection designs; external hex and internal tri-channel, using conventional screws and experimental conical screws. The study was divided in two parts; the first evaluated the effect of mechanical loading in the torque loss of the screws. 40 implants were used. The implants and abutments were divided in 4 groups: Group 1: external hex/conventional screw (HE); Group 2: tri-channel/conventional screw (TI); Group 3: external hex/conical screw (HECM); Group 4: tri-channel/conical screw (TICM). The abutments were installed in their respective implants with a tightening torque of 32Ncm, after a 10 minute interval, loosening torque were measured. The abutments were installed again with a 32Ncm torque, and after 10 minutes, they were mechanically loaded, simulating 1 year of normal oral function; after loading, loosening torques of the screws were measured again. Data were analyzed with one-way ANOVA test, with significance level of p&le;0,05. Optical microscopy analysis were performed before and after the tests. The second part evaluated the flexural resistance of the implant/abutment assemblies. The same 40 assemblies were used. The tests were performed in an universal testing machine, with a 500kgf load cell, 1mm/min displacement, and 45&deg; angulation. Maximum bending moment (FMF) and rupture force (FR) were determined. Collected information were analyzed with one-way ANOVA test, for p&le;0,05. Optical microscopy analysis were performed for study of the components after the flexural resistance tests. The results suggested that there were significant differences (p=0,000) in the residual preload before and after mechanical loading between the two types of screws: conical screws showed significantly higher loosening torques than conventional flat screws. There were significant differences in the FMF obtained by the conventional flat screws and by the conical screws (p=0,000); the implant/abutment assemblies with conical screws presented higher flexural resistance. For the FR results, there was significant influence of the type of connection (p=0,019); the tri-channel connection presented better results. Considering the limitations of this study, it was concluded that the conical screws presented higher loosening torques compared to conventional flat screws; the design of the implant/abutment connection presented no significant influence on the loosening torques of the screws; conical screws showed higher bending moment values; and the tri-channel connection obtained higher rupture force values.
18

Estudo mecânico da conexão implante/abutment utilizando parafusos convencionais e parafusos experimentais cone morse / Mechanical study of the implant/abutment connection using conventional screws and experimental conical screws

Abílio Ricciardi Coppedê 15 July 2011 (has links)
A proposta deste estudo foi avaliar o comportamento mecânico de dois designs de conexão implante/abutment; hexágono externo e triângulo interno, utilizando parafusos convencionais e parafusos experimentais cone morse. O estudo foi dividido em duas fases: na primeira, foi avaliado o efeito do carregamento mecânico na perda de torque dos parafusos. 40 implantes foram utilizados. Os implantes e abutments foram divididos em 4 grupos: Grupo 1: hexágono externo/parafuso convencional (HE); Grupo 2: triângulo interno/parafuso convencional (TI); Grupo 3: hexágono externo/parafuso cone morse (HECM); Grupo 4: triângulo interno/parafuso cone morse (TICM). Os abutments foram instalados em seus respectivos implantes com torque de aperto de 32Ncm; após intervalo de 10 minutos, foram medidos os valores dos torques de desaperto. Os abutments foram instalados novamente com torque de 32Ncm, e após 10 minutos foram carregados mecanicamente, simulando 1 ano de função oral normal; após o carregamento, os torques de desaperto dos parafusos foram medidos novamente. Os dados foram analisados com o teste one-way ANOVA, com nível de significância de p&le;0,05%. Análises por microscopia óptica foram realizadas antes e após os ensaios. Na segunda fase, foi avaliada a resistência à flexão dos conjuntos implante/abutment. Os mesmos 40 conjuntos foram utilizados. Os testes foram realizados em máquina universal de ensaios, com célula de carga de 500 kgf, deslocamento de 1mm/min, e inclinação de 45&deg;. A força máxima de flexão (FMF) e a força de ruptura (FR) foram determinadas. As informações coletadas foram analisadas com o teste one-way ANOVA, para p&le;0,05. Análises por microscopia óptica foram realizadas para estudo dos componentes após os ensaios de resistência flexural. Os resultados sugeriram que houve diferença significante (p=0,000) na pré-carga residual antes e após carregamento mecânico entre os dois tipos de parafuso: os parafusos cone morse apresentaram torques de desaperto significativamente superiores aos apresentados pelos parafusos planos convencionais. Houve diferença significante nos resultados da FMF obtidos pelos parafusos planos convencionais e pelos parafusos cone morse (p=0,011), sendo que os conjuntos implante/abutment com parafusos cone morse apresentaram maior resistência à flexão. Para os resultados da FR houve influência significante do tipo de conexão (p=0,019), com melhores resultados para a conexão triângulo interno. Considerando as limitações deste estudo, concluiu-se que os parafusos cone morse apresentaram maiores torques de desaperto em comparação aos parafusos planos convencionais; que o design da conexão protética não teve influência significante sobre o torque de desaperto dos parafusos; que os parafusos cone morse obtiveram maiores valores de resistência à flexão, e que a conexão em triângulo interno obteve maiores valores para a força de ruptura. / The purpose of this study was to evaluate the mechanical behavior of two implant/abutment connection designs; external hex and internal tri-channel, using conventional screws and experimental conical screws. The study was divided in two parts; the first evaluated the effect of mechanical loading in the torque loss of the screws. 40 implants were used. The implants and abutments were divided in 4 groups: Group 1: external hex/conventional screw (HE); Group 2: tri-channel/conventional screw (TI); Group 3: external hex/conical screw (HECM); Group 4: tri-channel/conical screw (TICM). The abutments were installed in their respective implants with a tightening torque of 32Ncm, after a 10 minute interval, loosening torque were measured. The abutments were installed again with a 32Ncm torque, and after 10 minutes, they were mechanically loaded, simulating 1 year of normal oral function; after loading, loosening torques of the screws were measured again. Data were analyzed with one-way ANOVA test, with significance level of p&le;0,05. Optical microscopy analysis were performed before and after the tests. The second part evaluated the flexural resistance of the implant/abutment assemblies. The same 40 assemblies were used. The tests were performed in an universal testing machine, with a 500kgf load cell, 1mm/min displacement, and 45&deg; angulation. Maximum bending moment (FMF) and rupture force (FR) were determined. Collected information were analyzed with one-way ANOVA test, for p&le;0,05. Optical microscopy analysis were performed for study of the components after the flexural resistance tests. The results suggested that there were significant differences (p=0,000) in the residual preload before and after mechanical loading between the two types of screws: conical screws showed significantly higher loosening torques than conventional flat screws. There were significant differences in the FMF obtained by the conventional flat screws and by the conical screws (p=0,000); the implant/abutment assemblies with conical screws presented higher flexural resistance. For the FR results, there was significant influence of the type of connection (p=0,019); the tri-channel connection presented better results. Considering the limitations of this study, it was concluded that the conical screws presented higher loosening torques compared to conventional flat screws; the design of the implant/abutment connection presented no significant influence on the loosening torques of the screws; conical screws showed higher bending moment values; and the tri-channel connection obtained higher rupture force values.
19

Análise fotoelástica das tensões geradas por diferentes planejamentos de próteses parciais fixas parafusadas sobre implantes cone morse / Photoelastic analyses of stress generated by different designs of screw-retained fixed partial denture on morse taper implants

Érica Miranda de Torres 01 July 2008 (has links)
A restauração protética deve receber e transmitir cargas funcionais aos implantes de forma controlada, a fim de minimizar a ocorrência de falhas mecânicas e biológicas. A concentração de tensões inadequadas na interface osso-implante pode provocar reabsorção óssea em torno dos implantes em níveis superiores aos considerados clinicamente aceitáveis. Não existe consenso na literatura quanto ao melhor planejamento protético para reabilitações parciais com múltiplos implantes adjacentes, a fim de minimizar as tensões geradas na interface osso-implante. A fotoelasticidade é uma técnica experimental para análise de tensões, bastante empregada devido à sua relativa simplicidade e confiabilidade quanto à correspondência clínica dos achados observados. O presente trabalho se propôs a avaliar, por meio de análise fotoelástica, o comportamento biomecânico de próteses parciais fixas parafusadas sobre implantes cone morse com coroas isoladas ou unidas, simulando a reabilitação de áreas posteriores com e sem a presença de elemento dental distal aos implantes, e ainda variando o tipo de material de recobrimento estético empregado na restauração protética (cerâmica ou resina), quando sobre estas próteses foram aplicadas diferentes tipos de cargas estáticas. Para tanto, foi confeccionado um modelo fotoelástico simulando um espaço protético intercalado, com ausência do segundo prémolar e primeiro molar, reabilitado por meio de quatro tipos de coroas parafusadas sobre dois implantes cone morse (Neodent) adjacentes: UC - coroas unidas com recobrimento estético em cerâmica; IC - coroas isoladas com recobrimento estético em cerâmica; UR - coroas unidas com recobrimento estético em resina; IR - coroas isoladas com recobrimento estético em resina. A adaptação marginal das coroas foi avaliada pela leitura dos desajustes verticais na interface coroa/pilar em microscópio ótico. Análise fotoelástica qualitativa foi realizada sob diferentes condições de aplicação de carga na superfície oslusal das coroas: oclusal distribuída (1kgf), puntiforme simultânea (1kgf), puntiforme alternada no molar e no pré-molar (0,5kgf). A primeira análise foi feita na presença de contato proximal efetivo entre as próteses e o dente a distal dos implantes. A segunda análise foi realizada após eliminar a coroa do dente distal no modelo fotoelástico. Registros fotográficos foram obtidos de cada situação de interesse para análise, a fim de facilitar a observação e comparação do padrão de distribuição das franjas isocromáticas em torno dos implantes. De acordo com os resultados obtidos pode-se concluir que a ferulização das coroas promoveu melhor distribuição de tensões em torno dos implantes. As restaurações metalocerâmicas resultaram em menor magnitude e concentração de tensões em torno dos implantes quando comparadas às restaurações metaloplásticas. A presença de um dente com ponto de contato efetivo na distal das coroas não modificou as tensões resultantes em torno dos implantes, mas este dente participou da distribuição de tensões para o modelo fotoelástico. A ausência de uma oclusão bem ajustada e distribuída sobre as restaurações protéticas pode provocar sobrecarga nos implantes. / Prosthetic restoration should suffer and apply functional loads over implants in a controlled way with the aim to reduce the occurrence of mechanical and biological failures. The concentration of inadequate stress on the implant-bone interface may cause bone resorption around implants at levels above those considered clinically acceptable. There is no consensus in the literature about the best prosthetic plan for partial rehabilitation with multiple adjacent implants, with the aim to reduce the stress generates over the implantbone interface. Photoelasticity is an experimental technique used to analyzes stress and is highly used due to its relative simplicity and reliability in terms of the clinical agreement of the findings. The purpose of the present study was to assess, using photoelastic analysis, the biomechanical behavior of screwretained fixed partial dentures on morse taper implants with individual or connected crowns, simulating the rehabilitation of posterior areas with or without the presence of a dental element distal to the implants. Furthermore, the analyses considered different esthetic materials used in prosthetic restorations (ceramic or resin), and different static loads were applied over the prostheses. To do this, a photoelastic model was fabricated simulating the missing of the second pre-molar and the first molar. The model was rehabilitated through four types of screw-retained crowns over two adjacent morse taper implants (Neodent): CC connected crowns with ceramic esthetic overlay; IC individual crowns with ceramic esthetic overlay; CR connected crowns with resin esthetic overlay; - IR - individual crowns with resin esthetic overlay. The crowns marginal fit was assessed by reading the vertical misfits on the crownabutment interface using an optic microscope. The qualitative photoelastic analysis was performed under the application of different loads on the crowns occlusal surface: distributed occlusal (1kgf), simultaneous punctiform (1kgf), alternate punctiform over the molar and pre-molar (0.5 kgf). The first analysis was done with an effective proximal contact between the prostheses and the distal tooth. The second analysis was performed after eliminating the crown of the distal tooth in the photoelastic model. Photoelastic records were obtained in each situation that was of any interest to the analysis, with the aim to make it easy to observe and compare the distribution standard of the isochromatic fringes around the implants. According to the obtained results, it is concluded that crown splint promoted better stress distribution around the implants. The metallo-ceramic restorations resulted in less magnitude and stress concentration around the implants compared to metaloplastic restorations. The presence of one tooth with an effective contact point on the crown distal did not change the resulting stress around the implants, but that tooth took part in the stress distribution for the photoelastic model. A bad distributed occlusion over the prosthetic restorations can cause overload on the implants.
20

Estudo biomecânico da conexão implante/pilar protético em implantes do sistema cone morse / Biomechanical study of the implant/abutment connection in implants with internal tapered connectios

Abílio Ricciardi Coppedê 19 December 2007 (has links)
Conexões em cone morse foram desenvolvidas para melhorar as propriedades biomecânicas e reduzir os problemas mecânicos encontrados nos sistemas de hexágono externo e interno. Este trabalho apresenta os resultados de dois estudos que investigaram as propriedades biomecânicas da conexão implante/pilar protético em implantes do sistema cone morse. A proposta do primeiro estudo foi avaliar o efeito do carregamento mecânico na perda de torque de pilares protéticos do sistema cone morse, e o efeito de ciclos sucessivos de inserção/remoção no torque de remoção destes pilares. 69 implantes cônicos foram utilizados. Os implantes e pilares foram divididos em 4 grupos: grupos 1 e 3 receberam pilares sólidos, e os grupos 2 e 4(a,b) receberam os pilares com parafuso trespassante. Nos grupos 1 e 2 os torques de instalação foram medidos, os pilares foram removidos, e os torques de remoção foram medidos; dez ciclos de inserção/remoção foram realizados para cada conjunto implante/pilar. Nos grupos 3 e 4(a,b) os pilares foram instalados e carregados mecanicamente; os pilares foram removidos e os torques de remoção foram medidos; dez ciclos de inserção/carregamento mecânico/remoção foram realizados para cada conjunto implante/pilar. Os dados foram analizados com o teste de Student-Newman-Keuls, com um nível de significância de p &le; 0,05%. A perda de torque foi maior nos grupos 4a e 2 (acima de 30%); seguidos pelo grupo 1 (10,5%); grupo 3 (5,4%); e grupo 4b (39% de ganho de torque). Todos os resultados foram significativamente diferentes. A comparação do número de ciclos mostrou que, com o aumento do número de ciclos de inserção/remoção, houve uma tendência de aumento na perda de torque, para todos os tipos de pilares e grupos. Concluiu-se que o carregamento mecânico aumentou o torque de remoção dos pilares carregados em comparação a pilares não-carregados, e que os valores dos torques de remoção decaíram conforme o número de ciclos de inserção/remoção aumentou. O objetivo do segundo estudo foi verificar se as diferenças estruturais entre os sistemas de implantes com conexão em hexágono internos e em cone morse influenciam sua resistência à fratura. Vinte implantes cônicos com dimensões de 4,4mm de diâmetro por 13mm de comprimento foram utilizados: 10 com conexão em hexágono interno (HI) e 10 com conexão em cone morse (CM) de 11,5&deg;. Vinte pilares foram utilizados, 10 para os implantes HI (com um parafuso trespassante de fixação), e 10 para os implantes CM (sólidos). Os testes foram realizados em uma máquina universal de ensaios, com uma célula de carga de 500 kgf, deslocamento de 1mm/min, numa inclinação de 45&deg; a força máxima de deformação (FMD) e a força de fratura (FF) foram analisadas. As informações coletadas foram analizadas com um teste paramétrico (teste \"t\" de Student, p &le; 0,05). A média da FMD para os implantes CM [90.58(6.72)kgf] foi estatisticamente superior à média da FMD para os implantes HI [83.73(4.94)kgf] (p=0.0182). A média da FF para os implantes HI foi 79.86(4.77)kgf. Nenhum dos implantes CM fraturou. Por meio de microscopia óptica, verificou-se que as fraturas nos implantes HI sempre ocorreram no parafuso de fixação. Embora os implantes CM não tenham fraturado, eles sofreram deformações permanentes em sua plataforma e no pilar protético. É possível concluir que o desenho sólido dos pilares CM proporciona maior resistência à deformação e à fratura em comparação aos pilares HI. / Internal tapered connections were developed to improve biomechanical properties and to reduce mechanical problems found in external and internal hex implants. This work presents the results of two studies that investigated the biomechanical properties of the implant/abutment connection in implants with internal tapered connections. The purpose of the first study was to evaluate the effect of mechanical loading on the torque loss of abutments with internal tapered connections, and the effect of repeated torque cycles on the removal torque of these abutments. 68 conical implants and two abutment types were used. The implants and abutments were divided into 4 groups: groups 1 and 3 received the solid abutments, groups 2 and 4(a,b) received the trespassing screw abutments. In groups 1 and 2 installation torques of the abutments were measured, the abutments were uninstalled, and removal torques were measured; ten insertion/removal cycles were performed for each implant/abutment assembly. In groups 3 and 4(a,b) the abutments were installed, mechanically loaded, uninstalled, and removal torques were measured; ten insertion/mechanical loading/removal cycles were performed for each implant/abutment assembly. Data were analyzed with the Student-Newman-Keuls test, with a significance level of p &le; 0.05. Torque loss was greater in groups 4a and 2 (over 30%), followed by group 1 (10.5%), group 3 (5.4%) and group 4b (39% torque gain). All results were significantly different. The comparison of the number of cycles showed that, as the insertion/removal cycles increased, removal torques tended to be lower, for all abutment types and groups. It was concluded that mechanical loading increased loosening torque of loaded abutments in comparison to unloaded abutments, and removal torque values decrease as the number of insertion/removal cycles increase. The objective of the second study was to verify if the differences in the design of the internal hex and the internal tapered connection implant systems influence their fracture resistance. Twenty tapered implants with dimensions of 4.3mm X 13mm were utilized: 10 with an internal hex (IH) connection and 10 with an 11.5&deg; conical tapered (CT) connection. Twenty abutments were utilized, 10 for the IH implants (with a trespassing fixation screw), and 10 for the CT implants (solid). The tests were carried out in a universal testing machine, with a 500kgf load cell, 1mm/min dislocation, and 45 degrees angulation. The maximum deformation force (MDF) and the fracture force (FF) were analyzed. The collected data were analyzed with a parametric test (Student\'s t, p<.05). The average MDF for the CT implants [90.58(6.72)kgf] was statistically higher than the average MDF for the IH implants [83.73(4.94)kgf] (p=0.0182). The average FF for the IH implants was 79.86(4.77)kgf. None of the CT implants fractured. By means of optical micrography, it was verified that the fractures in the IH implants occurred always in the fixation screw. Although the CT implants did not fracture, they showed permanent deformations in the abutment and in the platform. It is possible to conclude that the solid design of the CT abutments provides greater resistance to deformation and fracture when compared to the IH abutments.

Page generated in 0.1136 seconds