1

Use of Anaerobic Adhesive for Prevailing Torque Locking Feature on Threaded Product

Hernandez, Alan 01 January 2015 (has links)
The purpose of this research is to determine if anaerobic adhesive can be used as a prevailing torque locking feature. Maintaining preload in critical joints is the usual standard that anaerobic adhesives are held to in aerospace and other industry. To test if anaerobic adhesive can be used as a prevailing torque locking feature a test procedure was developed and implemented to measure the removal torque of threaded fasteners after an allotted cure time. In total, 191 threaded fasteners of different material and coatings were tested in the unseated and seated states with various strengths and varieties of anaerobic adhesive. A series of three tests were conducted: initial use, reuse with no added anaerobic adhesive, and a third test with added product to the bolt and nut to see how removal torque would behave in these conditions. It was found that using anaerobic adhesive as a prevailing torque locking feature is viable in many cases. No published work to date analyzes anaerobic adhesive at the standard of a prevailing torque locking feature.
2

Avaliação da biofuncionalidade dos implantes da liga Ti-35Nb-7Zr comparado aos implantes comerciais de Ti-Cp / Biofunctionality evaluation of a Ti-35Nb-7Zr implants compared to Ti-Cp implants

Mello, Fabia Zampieri D'Antola de 24 May 2017 (has links)
A Ti-35Nb-7Zr é uma liga Ti-ß desenvolvida pelo Grupo de Biomateriais da Escola de Engenharia de Lorena da Universidade de São Paulo, que demonstrou, em estudos anteriores, propriedades mecânicas favoráveis para ser usada como biomaterial, tais como, limite de resistência (~800 Mpa), resistência à corrosão e baixo módulo de elasticidade (33 GPa). Uma vez que o implante dentário traz melhores resultados no tocante à função mastigatória, fonação, conforto e estética, melhorando a qualidade de vida das pessoas, o presente estudo descreve a avaliação da biofuncionalidade dos implantes dentários da liga Ti-35Nb-7Zr comparados aos implantes comerciais de Ti-Cp da marca Titaniumfix. A biofuncionalidade foi avaliada por meio de testes in vitro e in vivo. A avaliação in vitro foi realizada com células mesenquimais indiferenciadas retiradas da medula óssea de fêmures de ratos, que foram cultivadas em meio de cultura osteogênico e posteriormente realizados os testes de citotoxicidade, quantificação de proteína total e avaliação da atividade da fosfatase alcalina. A avaliação in vivo compreendeu a realização de implantes de Ti-Cp Titaniumfix e da liga Ti-35Nb-7Zr em tíbias de coelhos para avaliação histológica, histomorfométrica por meio do cálculo da Fração da área óssea ocupada (BAFO) e aposição óssea, e de remoção ao torque com intuito de avaliar a osteointegração. Considerando os resultados obtidos nesta pesquisa, com relação aos testes in vitro, é possível concluir que a liga possui maior hidrofilicidade que o Ti-Cp; apresenta espraiamento celular similar ao Ti-Cp o que corrobora para o resultado de viabilidade celular classificando-a como não citotóxica. Nos testes de quantificação de proteína total e atividade da fosfatase alcalina a liga apresenta resultados similares ao Ti-Cp, favorecendo a ocorrência de diferenciação e proliferação das células osteoblásticas. Desta forma, pode-se concluir que a liga possui boa compatibilidade in vitro. Os resultados obtidos nas avaliações in vivo, por meio da fração de área óssea ocupada (BAFO), comprovam a semelhança entre a liga e o Ti-Cp pois tiveram o valor percentual de osso neoformado similar. A análise de fluorescência, após a administração dos marcadores tetraciclina e alizarina, mostra que a aposição óssea também foi semelhante entre a liga e o Ti-Cp nos períodos estudados. Com relação a força de interação avaliada pelo torque de remoção é possível afirmar que a liga apresenta osteointegração comparável aos implantes comerciais Ti-Cp. Esses resultados demonstraram que os implantes da liga Ti-35Nb-7Zr apresentaram biocompatibilidade e biofuncionalidade semelhantes ao dos implantes de Ti-Cp. Além de possuir um baixo módulo de elasticidade, a liga apresentou uma osteointegração bem similar ao Ti-Cp, reunindo características que demonstram seu potencial para ser usada como biomaterial intraósseo. / Ti-35Nb-7Zr is a Ti-ß alloy developed by the Biomaterials Group of the Lorena School of Engineering of the University of São Paulo, which demonstrated, in previous studies, favorable mechanical properties to be used as biomaterial, such as resistance (~800 Mpa), corrosion resistance and low modulus of elasticity (33 GPa). Since the dental implant brings better results regarding masticatory function, phonation, comfort and aesthetics, improving the quality of life of the people, the present study describes the evaluation of the biofunctionality of the Ti-35Nb-7Zr ally dental implants compared to the Titaniumfix implants of Ti-Cp. The biofunctionality was evaluated by means of in vitro and in vivo tests. The in vitro evaluation was perfomed with undifferentiated mesenchymal cells removed from the bone marrow of rat femurs, which were cultured in osteogenic culture medium and subsequently perfomed cytotoxicity tests, total protein quantification and evaluation of alkaline phosphatase activity. The in vivo evaluation included the implantation of Ti-Cp Titaniumfix and Ti-35Nb-7Zr alloy implants in rabbit tibiae for histological, histomorphometric evaluation by calculating the Bone Area Fractional Occupied (BAFO) and bone apposition, and torque removal in order to evaluate the osseointegration. Considering the results obtained in this research, related to in vitro tests, it is possible to conclude that the alloy has a higher hydrophilicity than Ti-Cp; Show cellular spreading similar to Ti-Cp, which corroborates the result of cell viability classifying it as non-cytotoxic. In the tests of total protein quantification and alkaline phosphatase activity the alloy presents results similar to Ti-Cp, favoring the occurrence of differentiation and proliferation of osteoblastic cells. In this way, it can be concluded that the alloy has good compatiblity in vitro. The results obtained in the in vivo evaluations, through the BAFO, confirm the similarity between the alloy and Ti-Cp, since they had the percentage value similar to neoformed bone. Fluorescence analysis, after administration of the tetracycline and alisarin markers, show that bone apposition was also similar between the alloy and Ti-Cp in the periods studied. Regarding the interaction force evaluated by the removal torque, it is possible to affirm that the alloy show osseointegration comparable to commercial Ti-Cp implants. These results demonstrated that Ti-35Nb-7Zr alloy implants had similar biocompatibility and biofunctionality to Ti-Cp implants. In addition to having a low modulus of elasticity, the alloy presented an osseointegration very similar to Ti-Cp, bringing together characteristics that demonstrate its potential to be used as an intraosseous biomaterial.
3

Desenvolvimento de uma bancada de teste para torque de parafusos para implantes

Wiedenhoft, Aldoni Gabriel January 2008 (has links)
Componentes de próteses e órteses humanas devem ser confortáveis, capazes de realizar as funções esperadas e, mais do que tudo, confiáveis. O foco deste trabalho é no desenvolvimento e aplicação de uma metodologia de análise de parafusos cirúrgicos. Para tanto foi desenvolvido um aparato mecânico, que consiste em um atuador de torque e um sistema de aquisição de dados. O atuador, composto por um motor elétrico acoplado a um redutor, aplica torque sobre o parafuso em teste, que o transfere a uma célula de carga e, assim, ao sistema de aquisição de dados. Parafusos canulados de aço inoxidável e corticais de titânio, de diferentes fabricantes, foram testados para torque de inserção e remoção, torque máximo e ângulo de ruptura. Os resultados mostraram que, apesar de todos os parafusos canulados seguirem os padrões recomendados, foram encontradas dispersões significativas entre os resultados verificados para os parafusos corticais de titânio, o que indica problemas de material ou manufatura. Os resultados mostraram valores mais elevados para torque de remoção que de inserção, o que, apesar de esperado, não é um efeito desejável, uma vez que facilita a fratura após a convalescência do paciente, em uma eventual remoção do parafuso. A análise dos resultados mostra a eficiência da metodologia desenvolvida, e chama a atenção para a confiabilidade dos componentes de órteses e próteses. / Human orthotic device components must be comfortable, able to execute the expected functions and, most of everything reliable. The focus of this work is the development and application of a surgical screw resistance analysis methodology. For this, a mechanical apparatus, consisting of a torque actuator and a data acquisition system was developed. The actuator, composed by an electric engine and reducer, applied torque on the tested screw, who transfers it to a load cell, especially developed, and thus to the data acquisition system. Cortical titanium and cannulated stainless steel bone screws were tested, from different manufacturers, for insertion and removal torque, maximum torque and rupture angle. The results showed that, despite that all cannulated screws had followed the recommended standards, it was found significant dispersion among the results for titanium cortical screws, which indicates manufacturing or material defects. Results also showed that removal torque was always higher than insertion torque. This is an undesirable, yet expected, effect, once fractures may come to happen after the healing of the patient, or even on the occasion of a substitution. The analysis showed the efficiency of the methodology developed, and opens a point of discussion on orthotic reliability.
4

Desenvolvimento de uma bancada de teste para torque de parafusos para implantes

Wiedenhoft, Aldoni Gabriel January 2008 (has links)
Componentes de próteses e órteses humanas devem ser confortáveis, capazes de realizar as funções esperadas e, mais do que tudo, confiáveis. O foco deste trabalho é no desenvolvimento e aplicação de uma metodologia de análise de parafusos cirúrgicos. Para tanto foi desenvolvido um aparato mecânico, que consiste em um atuador de torque e um sistema de aquisição de dados. O atuador, composto por um motor elétrico acoplado a um redutor, aplica torque sobre o parafuso em teste, que o transfere a uma célula de carga e, assim, ao sistema de aquisição de dados. Parafusos canulados de aço inoxidável e corticais de titânio, de diferentes fabricantes, foram testados para torque de inserção e remoção, torque máximo e ângulo de ruptura. Os resultados mostraram que, apesar de todos os parafusos canulados seguirem os padrões recomendados, foram encontradas dispersões significativas entre os resultados verificados para os parafusos corticais de titânio, o que indica problemas de material ou manufatura. Os resultados mostraram valores mais elevados para torque de remoção que de inserção, o que, apesar de esperado, não é um efeito desejável, uma vez que facilita a fratura após a convalescência do paciente, em uma eventual remoção do parafuso. A análise dos resultados mostra a eficiência da metodologia desenvolvida, e chama a atenção para a confiabilidade dos componentes de órteses e próteses. / Human orthotic device components must be comfortable, able to execute the expected functions and, most of everything reliable. The focus of this work is the development and application of a surgical screw resistance analysis methodology. For this, a mechanical apparatus, consisting of a torque actuator and a data acquisition system was developed. The actuator, composed by an electric engine and reducer, applied torque on the tested screw, who transfers it to a load cell, especially developed, and thus to the data acquisition system. Cortical titanium and cannulated stainless steel bone screws were tested, from different manufacturers, for insertion and removal torque, maximum torque and rupture angle. The results showed that, despite that all cannulated screws had followed the recommended standards, it was found significant dispersion among the results for titanium cortical screws, which indicates manufacturing or material defects. Results also showed that removal torque was always higher than insertion torque. This is an undesirable, yet expected, effect, once fractures may come to happen after the healing of the patient, or even on the occasion of a substitution. The analysis showed the efficiency of the methodology developed, and opens a point of discussion on orthotic reliability.
5

Desenvolvimento de uma bancada de teste para torque de parafusos para implantes

Wiedenhoft, Aldoni Gabriel January 2008 (has links)
Componentes de próteses e órteses humanas devem ser confortáveis, capazes de realizar as funções esperadas e, mais do que tudo, confiáveis. O foco deste trabalho é no desenvolvimento e aplicação de uma metodologia de análise de parafusos cirúrgicos. Para tanto foi desenvolvido um aparato mecânico, que consiste em um atuador de torque e um sistema de aquisição de dados. O atuador, composto por um motor elétrico acoplado a um redutor, aplica torque sobre o parafuso em teste, que o transfere a uma célula de carga e, assim, ao sistema de aquisição de dados. Parafusos canulados de aço inoxidável e corticais de titânio, de diferentes fabricantes, foram testados para torque de inserção e remoção, torque máximo e ângulo de ruptura. Os resultados mostraram que, apesar de todos os parafusos canulados seguirem os padrões recomendados, foram encontradas dispersões significativas entre os resultados verificados para os parafusos corticais de titânio, o que indica problemas de material ou manufatura. Os resultados mostraram valores mais elevados para torque de remoção que de inserção, o que, apesar de esperado, não é um efeito desejável, uma vez que facilita a fratura após a convalescência do paciente, em uma eventual remoção do parafuso. A análise dos resultados mostra a eficiência da metodologia desenvolvida, e chama a atenção para a confiabilidade dos componentes de órteses e próteses. / Human orthotic device components must be comfortable, able to execute the expected functions and, most of everything reliable. The focus of this work is the development and application of a surgical screw resistance analysis methodology. For this, a mechanical apparatus, consisting of a torque actuator and a data acquisition system was developed. The actuator, composed by an electric engine and reducer, applied torque on the tested screw, who transfers it to a load cell, especially developed, and thus to the data acquisition system. Cortical titanium and cannulated stainless steel bone screws were tested, from different manufacturers, for insertion and removal torque, maximum torque and rupture angle. The results showed that, despite that all cannulated screws had followed the recommended standards, it was found significant dispersion among the results for titanium cortical screws, which indicates manufacturing or material defects. Results also showed that removal torque was always higher than insertion torque. This is an undesirable, yet expected, effect, once fractures may come to happen after the healing of the patient, or even on the occasion of a substitution. The analysis showed the efficiency of the methodology developed, and opens a point of discussion on orthotic reliability.
6

Avaliação da biofuncionalidade dos implantes da liga Ti-35Nb-7Zr comparado aos implantes comerciais de Ti-Cp / Biofunctionality evaluation of a Ti-35Nb-7Zr implants compared to Ti-Cp implants

Fabia Zampieri D'Antola de Mello 24 May 2017 (has links)
A Ti-35Nb-7Zr é uma liga Ti-ß desenvolvida pelo Grupo de Biomateriais da Escola de Engenharia de Lorena da Universidade de São Paulo, que demonstrou, em estudos anteriores, propriedades mecânicas favoráveis para ser usada como biomaterial, tais como, limite de resistência (~800 Mpa), resistência à corrosão e baixo módulo de elasticidade (33 GPa). Uma vez que o implante dentário traz melhores resultados no tocante à função mastigatória, fonação, conforto e estética, melhorando a qualidade de vida das pessoas, o presente estudo descreve a avaliação da biofuncionalidade dos implantes dentários da liga Ti-35Nb-7Zr comparados aos implantes comerciais de Ti-Cp da marca Titaniumfix. A biofuncionalidade foi avaliada por meio de testes in vitro e in vivo. A avaliação in vitro foi realizada com células mesenquimais indiferenciadas retiradas da medula óssea de fêmures de ratos, que foram cultivadas em meio de cultura osteogênico e posteriormente realizados os testes de citotoxicidade, quantificação de proteína total e avaliação da atividade da fosfatase alcalina. A avaliação in vivo compreendeu a realização de implantes de Ti-Cp Titaniumfix e da liga Ti-35Nb-7Zr em tíbias de coelhos para avaliação histológica, histomorfométrica por meio do cálculo da Fração da área óssea ocupada (BAFO) e aposição óssea, e de remoção ao torque com intuito de avaliar a osteointegração. Considerando os resultados obtidos nesta pesquisa, com relação aos testes in vitro, é possível concluir que a liga possui maior hidrofilicidade que o Ti-Cp; apresenta espraiamento celular similar ao Ti-Cp o que corrobora para o resultado de viabilidade celular classificando-a como não citotóxica. Nos testes de quantificação de proteína total e atividade da fosfatase alcalina a liga apresenta resultados similares ao Ti-Cp, favorecendo a ocorrência de diferenciação e proliferação das células osteoblásticas. Desta forma, pode-se concluir que a liga possui boa compatibilidade in vitro. Os resultados obtidos nas avaliações in vivo, por meio da fração de área óssea ocupada (BAFO), comprovam a semelhança entre a liga e o Ti-Cp pois tiveram o valor percentual de osso neoformado similar. A análise de fluorescência, após a administração dos marcadores tetraciclina e alizarina, mostra que a aposição óssea também foi semelhante entre a liga e o Ti-Cp nos períodos estudados. Com relação a força de interação avaliada pelo torque de remoção é possível afirmar que a liga apresenta osteointegração comparável aos implantes comerciais Ti-Cp. Esses resultados demonstraram que os implantes da liga Ti-35Nb-7Zr apresentaram biocompatibilidade e biofuncionalidade semelhantes ao dos implantes de Ti-Cp. Além de possuir um baixo módulo de elasticidade, a liga apresentou uma osteointegração bem similar ao Ti-Cp, reunindo características que demonstram seu potencial para ser usada como biomaterial intraósseo. / Ti-35Nb-7Zr is a Ti-ß alloy developed by the Biomaterials Group of the Lorena School of Engineering of the University of São Paulo, which demonstrated, in previous studies, favorable mechanical properties to be used as biomaterial, such as resistance (~800 Mpa), corrosion resistance and low modulus of elasticity (33 GPa). Since the dental implant brings better results regarding masticatory function, phonation, comfort and aesthetics, improving the quality of life of the people, the present study describes the evaluation of the biofunctionality of the Ti-35Nb-7Zr ally dental implants compared to the Titaniumfix implants of Ti-Cp. The biofunctionality was evaluated by means of in vitro and in vivo tests. The in vitro evaluation was perfomed with undifferentiated mesenchymal cells removed from the bone marrow of rat femurs, which were cultured in osteogenic culture medium and subsequently perfomed cytotoxicity tests, total protein quantification and evaluation of alkaline phosphatase activity. The in vivo evaluation included the implantation of Ti-Cp Titaniumfix and Ti-35Nb-7Zr alloy implants in rabbit tibiae for histological, histomorphometric evaluation by calculating the Bone Area Fractional Occupied (BAFO) and bone apposition, and torque removal in order to evaluate the osseointegration. Considering the results obtained in this research, related to in vitro tests, it is possible to conclude that the alloy has a higher hydrophilicity than Ti-Cp; Show cellular spreading similar to Ti-Cp, which corroborates the result of cell viability classifying it as non-cytotoxic. In the tests of total protein quantification and alkaline phosphatase activity the alloy presents results similar to Ti-Cp, favoring the occurrence of differentiation and proliferation of osteoblastic cells. In this way, it can be concluded that the alloy has good compatiblity in vitro. The results obtained in the in vivo evaluations, through the BAFO, confirm the similarity between the alloy and Ti-Cp, since they had the percentage value similar to neoformed bone. Fluorescence analysis, after administration of the tetracycline and alisarin markers, show that bone apposition was also similar between the alloy and Ti-Cp in the periods studied. Regarding the interaction force evaluated by the removal torque, it is possible to affirm that the alloy show osseointegration comparable to commercial Ti-Cp implants. These results demonstrated that Ti-35Nb-7Zr alloy implants had similar biocompatibility and biofunctionality to Ti-Cp implants. In addition to having a low modulus of elasticity, the alloy presented an osseointegration very similar to Ti-Cp, bringing together characteristics that demonstrate its potential to be used as an intraosseous biomaterial.
7

Estudo biomecânico da conexão implante/pilar protético em implantes do sistema cone morse / Biomechanical study of the implant/abutment connection in implants with internal tapered connectios

Coppedê, Abílio Ricciardi 19 December 2007 (has links)
Conexões em cone morse foram desenvolvidas para melhorar as propriedades biomecânicas e reduzir os problemas mecânicos encontrados nos sistemas de hexágono externo e interno. Este trabalho apresenta os resultados de dois estudos que investigaram as propriedades biomecânicas da conexão implante/pilar protético em implantes do sistema cone morse. A proposta do primeiro estudo foi avaliar o efeito do carregamento mecânico na perda de torque de pilares protéticos do sistema cone morse, e o efeito de ciclos sucessivos de inserção/remoção no torque de remoção destes pilares. 69 implantes cônicos foram utilizados. Os implantes e pilares foram divididos em 4 grupos: grupos 1 e 3 receberam pilares sólidos, e os grupos 2 e 4(a,b) receberam os pilares com parafuso trespassante. Nos grupos 1 e 2 os torques de instalação foram medidos, os pilares foram removidos, e os torques de remoção foram medidos; dez ciclos de inserção/remoção foram realizados para cada conjunto implante/pilar. Nos grupos 3 e 4(a,b) os pilares foram instalados e carregados mecanicamente; os pilares foram removidos e os torques de remoção foram medidos; dez ciclos de inserção/carregamento mecânico/remoção foram realizados para cada conjunto implante/pilar. Os dados foram analizados com o teste de Student-Newman-Keuls, com um nível de significância de p &le; 0,05%. A perda de torque foi maior nos grupos 4a e 2 (acima de 30%); seguidos pelo grupo 1 (10,5%); grupo 3 (5,4%); e grupo 4b (39% de ganho de torque). Todos os resultados foram significativamente diferentes. A comparação do número de ciclos mostrou que, com o aumento do número de ciclos de inserção/remoção, houve uma tendência de aumento na perda de torque, para todos os tipos de pilares e grupos. Concluiu-se que o carregamento mecânico aumentou o torque de remoção dos pilares carregados em comparação a pilares não-carregados, e que os valores dos torques de remoção decaíram conforme o número de ciclos de inserção/remoção aumentou. O objetivo do segundo estudo foi verificar se as diferenças estruturais entre os sistemas de implantes com conexão em hexágono internos e em cone morse influenciam sua resistência à fratura. Vinte implantes cônicos com dimensões de 4,4mm de diâmetro por 13mm de comprimento foram utilizados: 10 com conexão em hexágono interno (HI) e 10 com conexão em cone morse (CM) de 11,5&deg;. Vinte pilares foram utilizados, 10 para os implantes HI (com um parafuso trespassante de fixação), e 10 para os implantes CM (sólidos). Os testes foram realizados em uma máquina universal de ensaios, com uma célula de carga de 500 kgf, deslocamento de 1mm/min, numa inclinação de 45&deg; a força máxima de deformação (FMD) e a força de fratura (FF) foram analisadas. As informações coletadas foram analizadas com um teste paramétrico (teste \"t\" de Student, p &le; 0,05). A média da FMD para os implantes CM [90.58(6.72)kgf] foi estatisticamente superior à média da FMD para os implantes HI [83.73(4.94)kgf] (p=0.0182). A média da FF para os implantes HI foi 79.86(4.77)kgf. Nenhum dos implantes CM fraturou. Por meio de microscopia óptica, verificou-se que as fraturas nos implantes HI sempre ocorreram no parafuso de fixação. Embora os implantes CM não tenham fraturado, eles sofreram deformações permanentes em sua plataforma e no pilar protético. É possível concluir que o desenho sólido dos pilares CM proporciona maior resistência à deformação e à fratura em comparação aos pilares HI. / Internal tapered connections were developed to improve biomechanical properties and to reduce mechanical problems found in external and internal hex implants. This work presents the results of two studies that investigated the biomechanical properties of the implant/abutment connection in implants with internal tapered connections. The purpose of the first study was to evaluate the effect of mechanical loading on the torque loss of abutments with internal tapered connections, and the effect of repeated torque cycles on the removal torque of these abutments. 68 conical implants and two abutment types were used. The implants and abutments were divided into 4 groups: groups 1 and 3 received the solid abutments, groups 2 and 4(a,b) received the trespassing screw abutments. In groups 1 and 2 installation torques of the abutments were measured, the abutments were uninstalled, and removal torques were measured; ten insertion/removal cycles were performed for each implant/abutment assembly. In groups 3 and 4(a,b) the abutments were installed, mechanically loaded, uninstalled, and removal torques were measured; ten insertion/mechanical loading/removal cycles were performed for each implant/abutment assembly. Data were analyzed with the Student-Newman-Keuls test, with a significance level of p &le; 0.05. Torque loss was greater in groups 4a and 2 (over 30%), followed by group 1 (10.5%), group 3 (5.4%) and group 4b (39% torque gain). All results were significantly different. The comparison of the number of cycles showed that, as the insertion/removal cycles increased, removal torques tended to be lower, for all abutment types and groups. It was concluded that mechanical loading increased loosening torque of loaded abutments in comparison to unloaded abutments, and removal torque values decrease as the number of insertion/removal cycles increase. The objective of the second study was to verify if the differences in the design of the internal hex and the internal tapered connection implant systems influence their fracture resistance. Twenty tapered implants with dimensions of 4.3mm X 13mm were utilized: 10 with an internal hex (IH) connection and 10 with an 11.5&deg; conical tapered (CT) connection. Twenty abutments were utilized, 10 for the IH implants (with a trespassing fixation screw), and 10 for the CT implants (solid). The tests were carried out in a universal testing machine, with a 500kgf load cell, 1mm/min dislocation, and 45 degrees angulation. The maximum deformation force (MDF) and the fracture force (FF) were analyzed. The collected data were analyzed with a parametric test (Student\'s t, p<.05). The average MDF for the CT implants [90.58(6.72)kgf] was statistically higher than the average MDF for the IH implants [83.73(4.94)kgf] (p=0.0182). The average FF for the IH implants was 79.86(4.77)kgf. None of the CT implants fractured. By means of optical micrography, it was verified that the fractures in the IH implants occurred always in the fixation screw. Although the CT implants did not fracture, they showed permanent deformations in the abutment and in the platform. It is possible to conclude that the solid design of the CT abutments provides greater resistance to deformation and fracture when compared to the IH abutments.
8

Estudo biomecânico da conexão implante/pilar protético em implantes do sistema cone morse / Biomechanical study of the implant/abutment connection in implants with internal tapered connectios

Abílio Ricciardi Coppedê 19 December 2007 (has links)
Conexões em cone morse foram desenvolvidas para melhorar as propriedades biomecânicas e reduzir os problemas mecânicos encontrados nos sistemas de hexágono externo e interno. Este trabalho apresenta os resultados de dois estudos que investigaram as propriedades biomecânicas da conexão implante/pilar protético em implantes do sistema cone morse. A proposta do primeiro estudo foi avaliar o efeito do carregamento mecânico na perda de torque de pilares protéticos do sistema cone morse, e o efeito de ciclos sucessivos de inserção/remoção no torque de remoção destes pilares. 69 implantes cônicos foram utilizados. Os implantes e pilares foram divididos em 4 grupos: grupos 1 e 3 receberam pilares sólidos, e os grupos 2 e 4(a,b) receberam os pilares com parafuso trespassante. Nos grupos 1 e 2 os torques de instalação foram medidos, os pilares foram removidos, e os torques de remoção foram medidos; dez ciclos de inserção/remoção foram realizados para cada conjunto implante/pilar. Nos grupos 3 e 4(a,b) os pilares foram instalados e carregados mecanicamente; os pilares foram removidos e os torques de remoção foram medidos; dez ciclos de inserção/carregamento mecânico/remoção foram realizados para cada conjunto implante/pilar. Os dados foram analizados com o teste de Student-Newman-Keuls, com um nível de significância de p &le; 0,05%. A perda de torque foi maior nos grupos 4a e 2 (acima de 30%); seguidos pelo grupo 1 (10,5%); grupo 3 (5,4%); e grupo 4b (39% de ganho de torque). Todos os resultados foram significativamente diferentes. A comparação do número de ciclos mostrou que, com o aumento do número de ciclos de inserção/remoção, houve uma tendência de aumento na perda de torque, para todos os tipos de pilares e grupos. Concluiu-se que o carregamento mecânico aumentou o torque de remoção dos pilares carregados em comparação a pilares não-carregados, e que os valores dos torques de remoção decaíram conforme o número de ciclos de inserção/remoção aumentou. O objetivo do segundo estudo foi verificar se as diferenças estruturais entre os sistemas de implantes com conexão em hexágono internos e em cone morse influenciam sua resistência à fratura. Vinte implantes cônicos com dimensões de 4,4mm de diâmetro por 13mm de comprimento foram utilizados: 10 com conexão em hexágono interno (HI) e 10 com conexão em cone morse (CM) de 11,5&deg;. Vinte pilares foram utilizados, 10 para os implantes HI (com um parafuso trespassante de fixação), e 10 para os implantes CM (sólidos). Os testes foram realizados em uma máquina universal de ensaios, com uma célula de carga de 500 kgf, deslocamento de 1mm/min, numa inclinação de 45&deg; a força máxima de deformação (FMD) e a força de fratura (FF) foram analisadas. As informações coletadas foram analizadas com um teste paramétrico (teste \"t\" de Student, p &le; 0,05). A média da FMD para os implantes CM [90.58(6.72)kgf] foi estatisticamente superior à média da FMD para os implantes HI [83.73(4.94)kgf] (p=0.0182). A média da FF para os implantes HI foi 79.86(4.77)kgf. Nenhum dos implantes CM fraturou. Por meio de microscopia óptica, verificou-se que as fraturas nos implantes HI sempre ocorreram no parafuso de fixação. Embora os implantes CM não tenham fraturado, eles sofreram deformações permanentes em sua plataforma e no pilar protético. É possível concluir que o desenho sólido dos pilares CM proporciona maior resistência à deformação e à fratura em comparação aos pilares HI. / Internal tapered connections were developed to improve biomechanical properties and to reduce mechanical problems found in external and internal hex implants. This work presents the results of two studies that investigated the biomechanical properties of the implant/abutment connection in implants with internal tapered connections. The purpose of the first study was to evaluate the effect of mechanical loading on the torque loss of abutments with internal tapered connections, and the effect of repeated torque cycles on the removal torque of these abutments. 68 conical implants and two abutment types were used. The implants and abutments were divided into 4 groups: groups 1 and 3 received the solid abutments, groups 2 and 4(a,b) received the trespassing screw abutments. In groups 1 and 2 installation torques of the abutments were measured, the abutments were uninstalled, and removal torques were measured; ten insertion/removal cycles were performed for each implant/abutment assembly. In groups 3 and 4(a,b) the abutments were installed, mechanically loaded, uninstalled, and removal torques were measured; ten insertion/mechanical loading/removal cycles were performed for each implant/abutment assembly. Data were analyzed with the Student-Newman-Keuls test, with a significance level of p &le; 0.05. Torque loss was greater in groups 4a and 2 (over 30%), followed by group 1 (10.5%), group 3 (5.4%) and group 4b (39% torque gain). All results were significantly different. The comparison of the number of cycles showed that, as the insertion/removal cycles increased, removal torques tended to be lower, for all abutment types and groups. It was concluded that mechanical loading increased loosening torque of loaded abutments in comparison to unloaded abutments, and removal torque values decrease as the number of insertion/removal cycles increase. The objective of the second study was to verify if the differences in the design of the internal hex and the internal tapered connection implant systems influence their fracture resistance. Twenty tapered implants with dimensions of 4.3mm X 13mm were utilized: 10 with an internal hex (IH) connection and 10 with an 11.5&deg; conical tapered (CT) connection. Twenty abutments were utilized, 10 for the IH implants (with a trespassing fixation screw), and 10 for the CT implants (solid). The tests were carried out in a universal testing machine, with a 500kgf load cell, 1mm/min dislocation, and 45 degrees angulation. The maximum deformation force (MDF) and the fracture force (FF) were analyzed. The collected data were analyzed with a parametric test (Student\'s t, p<.05). The average MDF for the CT implants [90.58(6.72)kgf] was statistically higher than the average MDF for the IH implants [83.73(4.94)kgf] (p=0.0182). The average FF for the IH implants was 79.86(4.77)kgf. None of the CT implants fractured. By means of optical micrography, it was verified that the fractures in the IH implants occurred always in the fixation screw. Although the CT implants did not fracture, they showed permanent deformations in the abutment and in the platform. It is possible to conclude that the solid design of the CT abutments provides greater resistance to deformation and fracture when compared to the IH abutments.
9

Avaliação da resistência ao arrancamento e do torque de remoção de um novo modelo de implante de zircônia / Analysis of pullout strength and removal torque of a new zirconia dental implants

Renata Espindola Silveira 15 January 2015 (has links)
O objetivo deste estudo foi avaliar comparativamente a estabilidade primária e a longevidade de implantes de zircônia (Y-TZP) e titânio (Grau IV) após ciclagem termomecânica (CTM). Foram obtidos 40 implantes de cada material que foram instalados em osso artificial e separados em grupos (n=10) segundo o material, a realização de ciclagem termomecânica e o ensaio realizado: Titânio - G1 (ensaio de torque de remoção); G2 (ensaio de arrancamento); G3 (CTM + ensaio de torque de remoção); G4 (CFTM + ensaio de arrancamento); e Zircônia - G5 (ensaio de torque de remoção); G6 (ensaio de arrancamento); G7 (CTM + ensaio de torque de remoção); G8 (CTM + ensaio de arrancamento). O equipamento de ciclagem mecânica foi configurado com carga de 133 N, frequência de 120 ciclos por minuto (2 Hz), totalizando 2.000.000 ciclos em cada espécime. A ciclagem térmica foi realizada com temperatura entre 5ºC, 37ºC e 55ºC. Após os ensaios mecânicos, os resultados foram submetidos à análise estatística (2-way ANOVA, teste de Bonferroni, p<0,05) e verificou-se que houve diferença estatisticamente significante (p<0,05) entre os implantes de titânio e zircônia, independente do tratamento utilizado, tanto para o torque de remoção quanto para a foça máxima de arrancamento. Os implantes de titânio mostraram maiores valores de torque de remoção e força de arrancamento comparado aos implantes de zircônia (p<0,05). Verificou-se também que a ciclagem termomecânica foi significante apenas para o ensaio de arrancamento quando utilizados implantes de titânio. Conclui-se que a estabilidade primária de implantes de titânio foi maior do que implantes de zircônia e que a ciclagem termomecânica foi um fator significativo apenas para a longevidade dos implantes de titânio. / The aim of this study was to assess comparatively the primary stability and longevity of zirconia (Y-TZP) and titanium (Grade IV) implants after thermomechanical cyclic (CTF). Forty implants to each material were obtained, installed in artificial bone and separated into groups (n=10) according to the material, the conducting of thermomechanical cyclic and the test submitted: Titanium - G1 (removal torque); G2 (pullout test); G3 (CTF + removal torque); G4 (TCF + pullout test); Zirconia - G5 (removal torque); G6 (pullout test); G7 (CTF + removal torque); G8 (CTF + pullout test). The mechanical cyclic testing machine was programmed to apply a load of 133 N, frequency of 120 cycles per minute (2 Hz) and a total of 2,000,000 cycles in each specimen. The thermocycling was set with a temperature between 5°C, 37ºC and 55ºC. After the mechanical tests, the data were subjected to statistical analysis (2-way ANOVA, Bonferroni test, p <0,05) and the results showed statistically significant difference (p <0.05) between zirconia and titanium implants, regardless of treatment used, for both removal torque and pullout tests. Titanium implants showed higher removal torque and pullout strength, which was statistically significant (p <0,05) compared with zirconia implants. It was also found that the thermomechanical cyclic was only significant for pullout test when used titanium implants. It was concluded that primary stability of titanium implants is higher than zirconia implants and the thermomechanical cyclic was a significant factor only for the longevity of titanium implants.
10

Avaliação da resistência ao arrancamento e do torque de remoção de um novo modelo de implante de zircônia / Analysis of pullout strength and removal torque of a new zirconia dental implants

Silveira, Renata Espindola 15 January 2015 (has links)
O objetivo deste estudo foi avaliar comparativamente a estabilidade primária e a longevidade de implantes de zircônia (Y-TZP) e titânio (Grau IV) após ciclagem termomecânica (CTM). Foram obtidos 40 implantes de cada material que foram instalados em osso artificial e separados em grupos (n=10) segundo o material, a realização de ciclagem termomecânica e o ensaio realizado: Titânio - G1 (ensaio de torque de remoção); G2 (ensaio de arrancamento); G3 (CTM + ensaio de torque de remoção); G4 (CFTM + ensaio de arrancamento); e Zircônia - G5 (ensaio de torque de remoção); G6 (ensaio de arrancamento); G7 (CTM + ensaio de torque de remoção); G8 (CTM + ensaio de arrancamento). O equipamento de ciclagem mecânica foi configurado com carga de 133 N, frequência de 120 ciclos por minuto (2 Hz), totalizando 2.000.000 ciclos em cada espécime. A ciclagem térmica foi realizada com temperatura entre 5ºC, 37ºC e 55ºC. Após os ensaios mecânicos, os resultados foram submetidos à análise estatística (2-way ANOVA, teste de Bonferroni, p<0,05) e verificou-se que houve diferença estatisticamente significante (p<0,05) entre os implantes de titânio e zircônia, independente do tratamento utilizado, tanto para o torque de remoção quanto para a foça máxima de arrancamento. Os implantes de titânio mostraram maiores valores de torque de remoção e força de arrancamento comparado aos implantes de zircônia (p<0,05). Verificou-se também que a ciclagem termomecânica foi significante apenas para o ensaio de arrancamento quando utilizados implantes de titânio. Conclui-se que a estabilidade primária de implantes de titânio foi maior do que implantes de zircônia e que a ciclagem termomecânica foi um fator significativo apenas para a longevidade dos implantes de titânio. / The aim of this study was to assess comparatively the primary stability and longevity of zirconia (Y-TZP) and titanium (Grade IV) implants after thermomechanical cyclic (CTF). Forty implants to each material were obtained, installed in artificial bone and separated into groups (n=10) according to the material, the conducting of thermomechanical cyclic and the test submitted: Titanium - G1 (removal torque); G2 (pullout test); G3 (CTF + removal torque); G4 (TCF + pullout test); Zirconia - G5 (removal torque); G6 (pullout test); G7 (CTF + removal torque); G8 (CTF + pullout test). The mechanical cyclic testing machine was programmed to apply a load of 133 N, frequency of 120 cycles per minute (2 Hz) and a total of 2,000,000 cycles in each specimen. The thermocycling was set with a temperature between 5°C, 37ºC and 55ºC. After the mechanical tests, the data were subjected to statistical analysis (2-way ANOVA, Bonferroni test, p <0,05) and the results showed statistically significant difference (p <0.05) between zirconia and titanium implants, regardless of treatment used, for both removal torque and pullout tests. Titanium implants showed higher removal torque and pullout strength, which was statistically significant (p <0,05) compared with zirconia implants. It was also found that the thermomechanical cyclic was only significant for pullout test when used titanium implants. It was concluded that primary stability of titanium implants is higher than zirconia implants and the thermomechanical cyclic was a significant factor only for the longevity of titanium implants.