• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 23
  • 19
  • Tagged with
  • 41
  • 37
  • 9
  • 9
  • 7
  • 7
  • 7
  • 7
  • 7
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Etude structure-fonction de l'hydrogénase à fer et ingénierie du métabolisme de l'hydrogène chez Clostridium acetobutylicum / Structure-function study of the FeFe-hydrogenase and hydrogen mtebolic engineering in clostridium acetobutylicum

Gauquelin, Charles 09 October 2017 (has links)
: Chez la bactérie Clostridium acetobutylicum, la production de dihydrogène est catalysée par des hydrogénases, enzymes impliquées dans l’oxydation de la ferrédoxine réduite, qui permet la réduction des protons et la formation du gaz. Toutes les hydrogénases à fer partagent un domaine protéique très conservé (le Domaine H), hébergeant le site catalytique inorganique (le Cluster H). L’enzyme CaHydA de C. acetobutylicum, possède également le Domaine F contenant en tous quatre centres fer-soufre dits accessoires. Au cours de ces travaux, l’implication des centres fer-soufre du Domaine F sur les capacités catalytiques de l’enzyme a été étudiée, ainsi que les mécanismes de transfert d’électrons entre l’enzyme et son partenaire physiologique d’oxydoréduction principal : la ferrédoxine 2[4Fe-4S]. Différents variants ciblés de l’hydrogénase ont été créés, produits puis purifiés afin de les caractériser par une combinaison de méthodes biochimiques, électrochimiques, spectroscopiques et de modélisation moléculaire. Ceci a permis de mettre en évidence pour la première fois l’implication des centres fer-soufre accessoires du Domaine F dans les capacités catalytiques de l’enzyme. Enfin, il a été démontré que le centre [2Fe-2S] de surface FS2 de l’enzyme était le point d’entrée des électrons provenant de la ferrédoxine réduite. / The hydrogenase of Clostridium acetobutylicum catalyses the oxydation of reduced ferredoxin, leading to reduction of protons and dihydrogen formation. Among the three different classes of hydrogenases, the [Fe-Fe] Hydrogenases harbor a very conserved domain (H-Domain) containing the inorganic catalytic site (Cluster H). CaHydA from C. acetobutylicum possesses, in addition, the F-Domain containing four accessory iron-sulfur clusters. The involvement of accessory iron-sulfur cluster of F-Domain on the catalytic capacities of the enzyme has never been assessed. Moreover, which of the two surface iron-sulfur cluster of the F-Domain who interacts with the physiological redox partner ferredoxin is unknown. Different CaHydA mutants enzymes, modified in the Fe-S cluster composition of the F-Domain have been purified, and spectroscopically, biochemically and electrochemically characterized. These mutants enzymes, impaired in their catalytic activity both in solution and wired to an electrode, suggested, for the first time that the Fe-S clusters of the F-Domain have a long-range thermodynamic effect on the H-cluster and modulate enzyme’s functions. Moreover, it has been shown, and confirmed by molecular modelling, that the [2Fe-2S] surface cluster FS2 of the enzyme is the entry point for the electrons coming from the reduced ferredoxin.
2

Etude dosimétrique et modélisation des composantes de la dose à distance pour les faisceaux d'électrons en radiothérapie externe / dosimetric study and modeling of electron beams components from electron beams used in external radiotherapy

Mohamad alabdoaburas, Mohamad 30 March 2017 (has links)
Les améliorations dans les procédures cliniques de radiothérapie ont conduit à des taux de survie élevés. En conséquence, les effets secondaires possibles de la dose délivrée aux tissus sains sont devenus une préoccupation croissante pour les radiothérapeutes. L’estimation de la dose aux tissus sains, y compris à distance du volume-cible présente un intérêt clinique croissant pour évaluer le risque aux structures sensibles situées hors du champ d’irradiation. Nos travaux antérieurs se sont focalisés sur l’évaluation la dose à distance des faisceaux de photons. La dose à distance due aux faisceaux d’électrons n’a jamais été prise en compte, ce qui peut conduire à des sous-estimations des doses à distance lorsque le traitement est fait entièrement ou partiellement par les électrons. C’est la raison pour laquelle, une étude approfondie de la dose à distance des faisceaux d’électrons est devenue indispensable. Dans le présent travail de thèse, nous avons dans un premier temps réalisé une étude expérimentale décrivant la dose à distance des faisceaux d’électrons de haute énergie produits par différents accélérateurs linéaires, équipés de différents types d’applicateurs. Nous avons analysé l’influence de différents paramètres du faisceau sur la dose à distance dont l’énergie du faisceau, la taille et le type de l’applicateur, la distance à l’axe du faisceau ainsi que la profondeur dans l’eau. Nous avons séparé la dose à distance en deux composantes principales : la dose due aux photons de bremsstrahlung et la dose due aux électrons diffusés. Ensuite, nous avons développé un modèle pour le calcul de la composante de la dose due aux photons de bremsstrahlung en tout point dans le patient, et un modèle pour le calcul de la dose due aux électrons diffusés en dehors du champ d’irradiation. Enfin, nous avons évalué l’application de nos modèles de calcul de dose à distance dans une situation clinique réelles afin de démontrer l’intérêt clinique de notre modélisation, l’objectif étant de mettre un point à terme, un outil logiciel innovant répondant à la fois aux besoins de l’optimisation de la radiothérapie moderne et à ceux de l’épidémiologie de la dose comme facteur de risque d’effets iatrogènes. / The large improvements in the radiotherapy (RT) procedures have led to high survival rates. So the possible side late effects of the radiotherapy due to the doses deposited into the normal tissues have become a growing concern for the radio-oncologists. The assessment of the dose outside the radiation field presents an important clinical benefit for estimating the risk at sensible structures situated partially or entirely outside the radiation field, especially in pediatric, pregnant patients or the patients having cardiac implantable devices. More understanding of side effects of RT will require not only improved control of the high doses delivered to the target volumes, but also better knowledge of the unintended but unavoidable lower doses delivered out of the target. In this context, most studies on out-of-field dose estimation focus on photon beams. Nevertheless, electron beams are still an important component of RT, for treating superficial tumors (at depths < 5 cm). The out-of-field dose from electron beams has never been taken account, which causes an under estimation of this dose when the radiotherapy is done only or partly by the electrons. For this reason, a detailed investigation of the out-of-field dose from electron beams is essential for better estimation of the out-of-field dose regardless the radiotherapy type. In this thesis, we have experimentally evaluated the out-of-field doses in high-energy electron beams for three linear accelerators equipped with different electron applicator types used in daily practice. The dependence of this dose on different parameters, such as the applicator size, the electron beam energy, the depth, and the off-axis distance have been investigated. The scattered electrons component and the bremsstrahlung photons component have been separated by a semi-experimental method. We have developed a multi-source model based on existing multi-scattering models for calculating the bremsstrahlung dose distribution at any point in the patient inside and outside the radiation field. We have also analytically calculated the scattered electrons dose distribution outside the radiation field. These two models permit to calculate the total out-of-field dose from electron beams anywhere in the patient. Finally, we have evaluated the application of our models of dose calculation in a real clinical situation in order to validate our software, the aim being to set up an innovative software tool, meeting both the needs of radiotherapy and epidemiology of the dose as a risk factor for iatrogenic effects
3

Design study of a Laser Plasma Wakefield Accelerator with an externally injected 10-MeV electron beam coming from a photoinjector / Étude d’un accélérateur à champ de sillage laser-plasma avec un faisceau d’électrons de 10 MeV injectés depuis un photoinjecteur

Wang, Ke 02 July 2019 (has links)
Nous étudions l’accélération d’un faisceau d’électrons provenant d’un photoinjecteur RF lorsque celui-ci est injecté dans le champ électrique à très fort gradient crée par un laser de forte puissance dans un plasma. Dans cette thèse la configuration d’une telle expérience est étudiée et des simulations du début à la fin sont présentées. Étant donné qu’un faisceau ultra-court d’électrons (quelques femto secondes) est nécessaire pour atteindre une faible dispersion en énergie dans le plasma, le faisceau d’électrons de 10 MeV provenant du photoinjecteur est comprimé en deux étapes. Le premier étage utilise une chicane coudée qui comprime le paquet d’électrons jusqu’à une durée de 69 fs, puis un deuxième étage qui utilise la méthode de regroupement par différence de célérité dans le plasma et qui comprime le paquet jusqu’à 4 fs avant qu’il ne soit accéléré. Le paquet d’électrons est comprimé transversalement avant d’être injecté dans le plasma. Le paquet d’électrons est focalisé transversalement avant d’être injecté dans le plasma. Une longue cellule plasma est utilisée pour créer le plasma en commençant plusieurs longueurs de Rayleigh avant le plan focal du laser, ce qui permet un regroupement par différence de célérité dans la première partie du plasma avec des contraintes relâchées sur la taille transverse du paquet d’électrons. La cellule plasma s’étend plusieurs longueurs de Rayleigh après le plan focal du laser pour supprimer la divergence angulaire du paquet d’électrons. Nous démontrons que le paquet d’électrons à la sortie du plasma a une énergie de plus d’une centaine de MeV avec une émittance plus petite que 1 µm, une charge plus grande que 7pC et une dispersion en énergie plus petite que 1,5% (largeur à mi-hauteur). Pour étendre la longueur d’accélération nous avons étudié le guidage du laser par un capillaire diélectrique creux et les résultats montrent que même dans le cas optimal le profile Gaussien usuel d’un laser n’est pas optimal, principalement à cause de la diffraction du laser sur les bords à l’entrée du capillaire. Un profile Gaussien aplatit est donc suggéré pour supprimer cette diffraction et il est montré que dans ce cas les électrons peuvent être accélérés sur plus de 10 longueurs de Rayleigh. / The acceleration of an externally injected 10MeV electron bunch coming from a RF photoinjector in a high gradient electric field excited in a plasma by a high power laser is studied. In this thesis, the configuration of such an experiment is studied and start to end simulations are presented. As an ultrashort electron bunch (several femtoseconds) is required to maintain a low energy spread beam in the plasma, the 10MeV electron bunch coming from the photoinjector is compressed in two stages. The first stage is realized using a dogleg chicane which compresses the electron bunch to 69fs, the second stage is realized with velocity bunching in the plasma that further compresses the electron bunch to 3fs before efficient acceleration. The electron bunch is transversely focused with a solenoid before being injected into the plasma. A long cell is used to create a plasma starting several Rayleigh lengths before the laser focal plane, allowing the velocity bunching in the first part of the plasma and relaxing constraints on the transverse bunch size. The cell extends several Rayleigh lengths after the laser focal plane to suppress the angular divergence of the electron bunch. We demonstrate that the electron bunch at the exit of the plasma has an energy of more than one hundred MeV, with an emittance smaller than 1 µm, a charge greater than 7pC and a FWHM energy spread smaller than 1.5%. To extend the acceleration section, the guiding of the laser beam with a hollow dielectric capillary is studied, the results show that even in the best matching conditions, the usual laser Gaussian transverse profile is not optimum, mainly because of the diffraction of the laser on the edges at the entrance of the capillary, a flattened Gaussian laser profile is then suggested to suppress this diffraction and the electrons can be accelerated over more than ten Rayleigh lengths.
4

Développement d’un accélérateur laser-plasma à haut taux de répétition pour des applications à la diffraction ultra-rapide d’électrons / Interaction of few-cycle laser pulses with plasmas : application to electron acceleration and generation of attosecond electron bunches

Beaurepaire, Benoit 16 September 2016 (has links)
La microscopie électronique et la diffraction d’électrons ont permis de comprendre l’organisation des atomes au sein de la matière. En utilisant une source courte temporellement, il devient possible de mesurer les déplacements atomiques ou les modifications de la distribution électronique dans des matériaux. A ce jour, les sources ultra-brèves pour les expériences de diffraction d’électrons ne permettent pas d’atteindre une résolution temporelle inférieure à la centaine de femtosecondes (fs). Les accélérateurs laser-plasma sont de bons candidats pour atteindre une résolution temporelle de l’ordre de la femtoseconde. De plus, ces accélérateurs peuvent fonctionner à haut taux de répétition, permettant d’accumuler un grand nombre de données.Dans cette thèse, un accélérateur laser-plasma fonctionnant au kHz a été développé et construit. Cette source accélère des électrons à une énergie de 100 keV environ à partir d’impulsions laser d’énergie 3 mJ et de durée 25 fs. La physique de l’accélération a été étudiée, démontrant entre autres l’effet du front d’onde laser sur la distribution transverse des électrons.Les premières expériences de diffraction avec ce type de sources ont été réalisées. Une expérience de preuve de principe a montré que la qualité de la source est suffisante pour obtenir de belles images de diffraction sur des feuilles d’or et de silicium. Dans un second temps, la dynamique structurelle d’un échantillon de Silicium a été étudiée avec une résolution temporelle de quelques picosecondes, démontrant le potentiel de ce type de sources.Pour augmenter la résolution temporelle à sub-10 fs, il est nécessaire d’accélérer les électrons à des énergies relativistes de quelques MeV. Une étude numérique a montré que l’on peut accélérer des paquets d’électrons ultra-courts grâce à des impulsions laser de 5 mJ et 5 fs. Il serait alors possible d’atteindre une résolution temporelle de l’ordre de la femtoseconde. Finalement, une expérience de post-compression des impulsions laser due à l’ionisation d’un gaz a été réalisée. La durée du laser a pu être réduite d’un facteur deux, et l’homogénéité de ce processus a été étudiée expérimentalement et numériquement. / Electronic microscopy and electron diffraction allowed the understanding of the organization of atoms in matter. Using a temporally short source, one can measure atomic displacements or modifications of the electronic distribution in matter. To date, the best temporal resolution for time resolved diffraction experiments is of the order of a hundred femtoseconds (fs). Laser-plasma accelerators are good candidates to reach the femtosecond temporal resolution in electron diffraction experiments. Moreover, these accelerators can operate at a high repetition rate, allowing the accumulation of a large amount of data.In this thesis, a laser-plasma accelerator operating at the kHz repetition rate was developed and built. This source generate electron bunches at 100 keV from 3 mJ and 25 fs laser pulses. The physics of the acceleration has been studied, and the effect of the laser wavefront on the electron transverse distribution has been demonstrated.The first electron diffraction experiments with such a source have been realized. An experiment, which was a proof of concept, showed that the quality of the source permits to record nice diffraction patterns on gold and silicium foils. In a second experiment, the structural dynamics of a silicium sample has been studied with a temporal resolution of the order of a few picoseconds.The electron bunches must be accelerated to relativistic energies, at a few MeV, to reach a sub-10 fs temporal resolution. A numerical study showed that ultra-short electron bunches can be accelerated using 5 fs and 5 mJ laser pulses. A temporal resolution of the order of the femtosecond could be reached using such bunches for electron diffraction experiments. Finally, an experiment of the ionization-induced compression of the laser pulses has been realized. The pulse duration was shorten by a factor of 2, and the homogeneity of the process has been studied experimentally and numerically.
5

High-repetition-rate relativistic electron acceleration in plasma wakefields driven by few-cycle laser pulses / L’accélération des électrons relativistes à haute cadence dans les sillages plasma générés par des impulsions laser de quelques cycles optiques

Gustas, Dominykas 14 December 2018 (has links)
Le progrès continu de la technologie laser a récemment permis l’avancement spectaculaire d’accélérateurs de particules par onde de sillage. Cette technique permet la génération de champs électriques très forts, pouvant dépasser de trois ordres de grandeurs ceux présents dans les accélérateurs conventionnels. L’accélération résultante a lieu sur une distance très courte, par conséquent les effets de la charge d’espace et de la dispersion de vitesse sont considérablement réduits. Les paquets de particules ainsi générés peuvent alors atteindre des durées de l’ordre de la femtoseconde, qui en fait un outil prometteur pour la réalisation d’expériences de diffraction ultra-rapide avec une résolution inégalée de l’ordre de quelques femtosecondes. La génération de tels paquets d’électrons avec des lasers de 1 J et d’une durée de 30 fs est à présent bien établie. Ces paramètres permettent de produire des faisceaux d’électrons de quelques centaines de MeV, et sont donc inadaptés aux expériences de diffraction. De plus, le taux de répétition de ces lasers de haute puissance est limité à quelques Hz, ce qui est insuffisant pour des expériences exigeant une bonne statistique de mesure. Notre groupe a utilisé un laser de pointe développé au laboratoire par le groupe PCO générant des impulsions de quelques millijoules, d’une durée de 3.4 fs - à peine 1.3 cycle optique - à une cadence de 1 kHz, pour accélérer des électrons par onde de sillage. Ce travail de thèse présente d’une part la première démonstration d’un accélérateur des particules relativistes opéré dans le régime de la bulle à haute cadence. L’utilisation de buses microscopiques a permis l’obtention de charges de dizaines de pC par tir. De plus, cette thèse vise à l’élargissement de notre compréhension des lois d’échelle d’accélération laser-plasma. Nous espérons que notre travail visant à la fiabilisation et l’optimisation de cette source permettra à terme de proposer un instrument accessible et fiable à la communauté scientifique, que ce soit pour la diffraction d’électrons, l’irradiation ultra-brève d’échantillons ou la génération de rayons X. / Continuing progress in laser technology has enabled dramatic advances in laser wakefield acceleration (LWFA), a technique that permits driving particles by electric fields three orders of magnitude higher than in conventional radio-frequency accelerators. Due to significantly reduced space charge and velocity dispersion effects, the resultant relativistic electron bunches have also been identified as a candidate tool to achieve unprecedented sub-10 fs temporal resolution in ultrafast electron diffraction (UED) experiments. High repetition rate operation is desirable to improve data collection statistics and thus washout shot-to-shot charge fluctuations inherent to plasma accelerators. It is well known that high-quality electron beams can be achieved in the blowout, or "bubble" regime, which is at present regularly accessed with ≈ 30 fs Joule-class lasers that can perform up to few shots per second. Our group on the contraryutilized a cutting edge laser system producing few-mJ pulses compressed nearly to a single optical cycle (3.4 fs) to demonstrate for the first time an MeV-grade particle accelerator with properties characteristic to the blowout regime operating at 1 kHz repetition rate. We further investigate the plasma density profile and exact laser pulse waveform effects on the source output, and show that using special gas microjets a charge of tens of pC/shot can be achieved. We expect this technique to lead to a generation of highly accessible and robust instruments for the scientific community to conduct UED experiments or to be used for other applications. This work also serves to expand our knowledge on the scalability of laser-plasma acceleration.
6

Conception de biofilms bactériens artificiels électroactifs en vue d’optimiser les réactions de transferts extracellulaires d’électrons / Conception of an artificial electroactive biofilm in order to promote electron transfer reactions

Pinck, Stéphane 24 November 2017 (has links)
Nous avons cherché dans ce travail à élaborer un biofilm artificiel électroactif dans le but de promouvoir les réactions de transfert extracellulaire d’électrons (EET) en reconstituant artificiellement un biofilm en présence de matériaux exogènes. Un matériau composite auto-assemblé constitué de cellules bactériennes (Shewanella oneidensis), de nanotubes de carbone et de cytochromes c exogènes (issue de cellules de cœur de bœuf) a été tout d’abord proposé. Le processus d’auto-assemblage a été étudié par diffusion de lumière dynamique, microscopie électronique à balayage et spectroscopie Raman. Ces analyses ont mis en évidence l’importance du cytochrome exogène dans l’assemblage et l’organisation du matériau. La viabilité bactérienne a été étudiée et l’activité métabolique a été caractérisée par électrochimie. Les courants à l’anode étaient 10 et 4 fois plus importants avec ce biofilm artificiel (0,027 A m-2) qu’avec les électrodes modifiées par les bactéries seules (0,003 A m-2) ou associées au cytochrome c (0,007 A m-2). Le biofilm artificiel a été testé en substituant S. oneidensis par Pseudomonas fluorescens, produisant un courant d’oxydation lors de l’ajout de 1,5 mM de glucose. Le cytochrome c possède, outre son rôle structurant, une activité de navette à électrons. Son potentiel redox, 254 mV (vs NHE), était adapté à l’oxydation du formiate mais inadapté à la réduction du fumarate. Pour cette raison, il a été substitué par d’autres cytochromes (c3DvH, c7Da, c553DvH, c3DdN ou c3Dg) possédant des potentiels redox plus bas, de 20 mV à -400 mV. Ces cytochromes variaient aussi au niveau de leur charge à pH neutre, permettant de valider l’importance des forces électrostatiques dans l’assemblage du biocomposite. Les résultats optimaux obtenus avec c3DvH et c7Da ont montré l’importance du potentiel redox des éléments exogènes pour l’EET. Nous avons ensuite remplacé le cytochrome c par la protamine. Cette protéine non électroactive a permis l’assemblage du biocomposite tout en maintenant les transferts directs d’électrons entre les bactéries et les différents nanomatériaux testés. Les optimisations ont permis d’atteindre des courants cathodiques de plus de 12 A m-2 en présence de 50 mM de fumarate. Les expériences de stabilité ont montré la présence d’un courant biotique de 1,75 A m-2 après 24 h de réduction de 50 mM de fumarate / The aim of this PhD work was to design an artificial electroactive biofilm in order to optimize extracellular electron transfers (EET) by artificially reconstituting the biofilm in the presence of exogenous materials. A biocomposite material was proposed from the self-assembly of the bacteria Shewanella oneidensis with carbon nanotubes and cytochrome c (extract from bovine heart). The self-assembly was first studied by diffusion light scattering, scanning electron microscopy and Raman spectroscopy. These analyzes showed the importance of the cytochrome c in the assembly and organization of the biocomposite. Bacterial viability was studied and metabolic activity was characterized with the help of electrochemistry. The current at the anode was 10 and 4 times higher with the artificial biofilm (0.027 A m2) than with film composed with bacteria alone (0.003 A m2) or associated with cytochrome c (0.007 A m2). Artificial biofilm was also tested with Pseudomonas fluorescens instead of S. oneidensis, producing an oxidative current upon the addition of 1.5 mM glucose. That indicates cytochrome c has, in addition to its structuring role, an electron shuttle activity. Its redox potential, +254 mV (vs. NHE), was adapted to the oxidation of formate but was unsuitable for the reduction of fumarate. For this reason, it has been substituted by other cytochromes, c3DvH, c7Da, c553DvH, c3DdN, and c3Dg, possessing lower redox potentials, in the range of 20 mV to -400 mV. These cytochromes also varied at the level of their charge at neutral pH and allowed to validate the importance of the electrostatic forces in the assembly of the biocomposite. The optimal results obtained with c3DvH and c7Da showed the importance of the redox potential of the exogenous elements for the EET. We then replaced the cytochrome c with protamine. This non-electroactive protein allowed the assembly of the biocomposite by promoting direct electrons transfer between the bacteria and the different nanomaterials tested. The optimizations made it possible to reach cathodic currents of more than 12 A m2 in the presence of 50 mM of fumarate. The stability experiments showed the presence of a biotic current of 1.75 A m2 after 24 h of reduction of 50 mM of fumarate
7

Optimisation de la détection térahertz (THz) par plasmons bidimensionnels (2D) dans des hétérostructures et de la propagation THz dans des guides d’onde planaires / Optimization of THz detection by two dimensional plasmons in heterostructures and THz propagation in planar waveguides

Cao, Lei 01 February 2013 (has links)
Dans la gamme de fréquence térahertz (THz), les sources et les détecteurs couramment utilisés en optique et en électronique présentent une chute de performances. Mon travail de thèse s’inscrit dans le cadre de la recherche de composants THz peu onéreux, compacts, accordables en fréquence et facile à intégrer. Le premier volet de mon travail de thèse concerne la détection THz et met à profit le couplage entre une onde incidente THz et des plasmons d’un gaz bidimensionnel d’électrons (2DEG) via des réseaux métalliques déposés au-dessus d’hétérostructures. Quatre puits quantiques à base de semi-conducteurs III/V(AlGaN/GaN, AlGaAs/GaAs, InAlN/GaN) et IV/IV (SiGe/Si/SiGe) ont été étudiés. Parmi les hétérostructures envisagées, celles réalisées à partir de matériaux III-N présentent les plus fortes résonances. Des mesures de spectre de transmission ont été effectuées avec un spectromètre à transformée de Fourier (FTIR) à température ambiante et cryogénique. Les modélisations numériques sont en bon accord avec les résultats expérimentaux. Une étude sur l’influence de la distribution homogène ou inhomogène du gaz d’électrons 2D est présentée. Le deuxième volet de la thèse concerne l’optimisation de la transmission THz. Les performances (dipsersions et les pertes) des guides d'onde planaires sont mal connues au THz. Nous avons choisi d’étudier des guides d’onde couramment utilisés en hyperfréquence. Dans un premier temps, la dispersion et les pertes (rayonnement, conduction et diélectrique) de lignes coplanaires (CPW) sur substrat polymère (BCB = benzocyclobutène) et substrat semiconducteur (InP) obtenues grâce à des modélisations numériques (Ansoft HFSS) entre 20 GHz et 1 THz sont présentées. Puis d’autres types de guides ont été envisagés tels que les lignes micro-ruban, à fente et triplaques sur substrat BCB avec HFSS et CST MWS. Leurs performances ont été comparées afin de dégager la structure la plus performante au THz. Des mesures entre 340 et 500 GHz ont pu aussi être réalisées pour les guides CPW. La comparaison avec les données numériques a montré un bon accord. / In the THz frequency gap between electronics and optics, the development of compact, tunable, less costly and room temperature operating sources, detectors, amplifiers and passive devices is growing. Electronic devices based on two dimensional (2D) plasmons in heterostructures open up the possibility of tunable emission and detection of THz radiation. For short distance THz transmission, the increased radiation loss as well as other types of loss (dielectric and ohmic loss) may handicap the applications of conventional planar waveguides well studied in the microwave band. Reevaluation of their propagation properties and comprehension of the physical nature of each kind of loss are necessary.This work is divided into two main sections. The first part deals with the optimization of THz resonant detection by quasi 2D plasmons-polaritons (PP) in the quantum wells (QW) among four heterostructures: III-V (AlGaN/GaN, InAlN/GaN, AlGaAs/GaAs) and IV-IV (SiGe/Si/SiGe). With the aid of metallic grating coupler, both ANSOFT HFSS and an indigenously developed program are used to investigate quantitatively the influences of structural parameters (grating period, metal strip width and thickness of barrier layer) and natural properties of 2D plasmons (electron concentration and mobility) on the PP resonances (frequency and amplitude) up to 5 THz. Transmission spectra of sample AlGaN/GaN have been measured by Fourier Transform Infrared Spectroscopy (FTIR) in 0.6-1.8 THz for various metal widths and at different temperatures to compare with the simulated results. At last, two types of modulated 2D electron gas in AlGaAs/GaAs are analyzed. One is the natural electron variation below and between metal fingers due to the difference between the barrier height at the interface metal/semiconductor and Fermi level pinning at the interface air/semiconductor. The other type is the forced modulated 2DEG by biasing voltage on metal fingers. These two parametric studies allow us to analyze and tune the frequency and amplitude of the THz detection. The second part separately studies the dispersions and attenuations of four waveguides (CPW, Microstrip, Stripline and Slotline) with the variation of geometric dimensions and properties of dielectric and metal by ANSOFT HFSS and CST MWS. Their performances are compared until 1 THz based on the same characteristic impedance. The advantages and the limitations of each waveguide are outlined and an optimal THz transmission line is proposed. Furthermore, preliminary measured attenuation of CPW in the frequency range 340-500 GHz are demonstrated and compared with numerical results. The design of transitions for adapting experimental probes by HFSS and the de-embedding method for extracting scattering and attenuation parameters of CPW by ADS are also presented..
8

Etude de la production, de la propagation et de la focalisation d'un faisceau d'électrons impulsionnel intense / Study of the production, the propagation and the focusing of an electron beam

Pepitone, Kévin 08 October 2014 (has links)
Le faisceau d’électrons (500 keV, 30 kA, 100 ns) produit par le générateur RKA (Relativistic Klystron Amplifier) est utilisé pour étudier des matériaux soumis à des chocs de basse fluence (< 10 cal/cm²). Leur réponse dépend des caractéristiques du faisceau, principalement en termes d’homogénéité spatiale lors de l’impact. Dans ce but, nous avons utilisé des diagnostics électriques et un diagnostic optique basé sur l’émission Cerenkov. Les photons visibles produits sont détectables par des caméras rapides. Nous avons ainsi pu étudier l’homogénéité du faisceau émis dans la diode sous vide en fonction des matériaux utilisés pour la cathode et pour l’anode, mais aussi pu suivre sa propagation dans une enceinte contenant un gaz à basse pression.Chaque partie de l’installation a été optimisée lors de cette thèse. Nous avons constaté qu’une cathode en velours avec des fibres bien ordonnées était le meilleur émetteur. Une anode d’une dizaine de micromètres d’épaisseur permet de diffuser le faisceau avant qu’il n’impacte la cible, améliorant encore son homogénéité. Ces travaux sur la diode ont été complétés par une étude de la propagation du faisceau dans une enceinte remplie d’air ou d’argon à différentes pressions, avec ou sans focalisation produite par un champ magnétique externe. D’après les résultats expérimentaux, un faisceau d’électrons de 400 keV, 4,2 kA peut être propagé, avec un rayon constant, dans 0,7 mbar d’argon. Enfin, pour interpréter les expériences, des simulations ont été réalisées à l’aide du code Monte Carlo Geant4 pour calculer l’interaction du faisceau avec la cible Cerenkov et l’anode. Au niveau de l’émission et du transport du faisceau, le bon accord obtenu avec les prédictions du code PIC Magic permet d’estimer les distributions des électrons par la simulation et d’initialiser correctement les calculs de réponse des matériaux. / The electron beam (500 keV, 30 kA, 100 ns) of the RKA (Relativistic Klystron Amplifier) generator is used to study materials under shocks at low fluences (< 10 cal/cm²). Their response depends on the beam characteristics at the impact location, mainly in terms of spatial homogeneity. We have used electrical diagnostics as well as an optical diagnostics where the visible photons produced by Cerenkov emission in a silica target are collected by fast cameras. Beam homogeneity has been studied in the vacuum diode as a function of the materials used for the cathode and the anode. Beam propagation and focusing in a chamber filled with a low-pressure gas has also been investigated.Each part of the installation has been optimized during this work. We found that, among the tested materials, a velvet cathode with well-aligned fibers is the best emitter. An anode of thickness about ten micrometers improves the beam homogeneity by scattering of electrons. Next, we focused on beam propagation and focusing in the chamber. For example, a 400 keV, 4.2 kA electron beam can be propagated at constant radius in argon at 0.7 mbar. We performed simulations with the Monte Carlo code Geant4 in order to compute the beam interaction with the Cerenkov target as well as with the anode. Beam emission and propagation were simulated with the PIC code Magic. The good agreement with the experimental results allows us to estimate the electron distributions at any position along the beam path in order to initialize correctly the computation of the beam-material interaction.
9

Evaluation de la dose déposée par des faisceaux d'électrons en radiothérapie dans des fantômes voxelisés en utilisant la plateforme de simulation Monte Carlo GATE fondée sur GEANT4 dans un environnement de grille / Evaluation of the dose deposited by electron beams in radiotherapy in voxelized phantoms using the Monte Carlo GATE simulation platform based on GEANT4 in a grid environment

Perrot, Yann 08 December 2011 (has links)
La planification de traitement en radiothérapie nécessite un calcul précis de la dose délivrée au patient. La méthode la plus fiable pour y parvenir est la simulation du transport des particules par technique Monte Carlo. Cette thèse constitue la première étude concernant la validation de la plateforme de simulation Monte Carlo GATE (GEANT4 Application for Tomographic Emission), basée sur les librairies de GEANT4 (GEometry ANd Tracking), pour le calcul de la dose absorbée déposée par des faisceaux d’électrons. L’objectif de cette thèse est de montrer que GATE/GEANT4 est capable d’atteindre le niveau d’exigences requis pour le calcul de la dose absorbée lors d’une planification de traitement, dans des situations où les algorithmes analytiques, actuellement utilisés dans les services de radiothérapie, n’atteignent pas un niveau de précision satisfaisant. L’enjeu est de prouver que GATE/GEANT4 est adapté pour la planification de traitement utilisant des électrons et capable de rivaliser avec d’autres codes Monte Carlo reconnus. Cet enjeu a été démontré par la simulation avec GATE/GEANT4 de faisceaux et des sources d’électrons réalistes utilisées en radiothérapie externe ou en radiothérapie moléculaire et la production de distributions de dose absorbée en accord avec les mesures expérimentales et avec d’autres codes Monte Carlo de référence pour la physique médicale. Par ailleurs, des recommandations quant à l’utilisation des paramètres de simulation à fixer, assurant un calcul de la distribution de dose absorbée satisfaisant les spécifications en radiothérapie, sont proposées. / Radiation therapy treatment planning requires accurate determination of absorbed dose in the patient. Monte Carlo simulation is the most accurate method for solving the transport problem of particles in matter. This thesis is the first study dealing with the validation of the Monte Carlo simulation plateform GATE (GEANT4 Application for Tomographic Emission), based on GEANT4 (GEometry And Tracking) libraries, for the computation of absorbed dose deposited by electron beams. This thesis aims at demonstrating that GATE/GEANT4 calculations are able to reach treatment planning requirements in situations where analatycal algorithms are not satisfactory. The goal is to prove that GATE/GEANT4 is useful for treatment planning using electrons and competes with well validated Monte Carlo codes. This is demonstrated by the simulations with GATE/GEANT4 of realistic electron beams and electron sources used for external radiation therapy or targeted radiation therapy. The computed absorbed dose distributions are in agreement with experimental measurements and/or calculations from other Monte Carlo codes. Furthermore, guidelines are proposed to fix the physics parameters of the GATE/GEANT4 simulations in order to ensure the accuracy of absorbed dose calculations according to radiation therapy requirements.
10

Mise en oeuvre d'un mode d'imagerie par transillumination et détection multi-vue à ultra-faible bruit dans l'imageur QOS[indice supérieur TM] pour imagerie moléculaire optique sur petit animal / Implementation of transillumination mode and ultra-low noise multi-view detection in the QOS[superscript TM] for small animal optical molecular imaging

Zarif Yussefian, Nikta January 2014 (has links)
La tomographie optique diffuse (TOD) est une technique d’imagerie médicale relativement récente qui utilise la lumière dans le proche infrarouge pour acquérir des images in vivo de façon non invasive. Cette technique est en utilisation croissante par de nombreux chercheurs et biologistes et plusieurs équipes dans le monde travaillent sur le développement de scanners par TOD y compris notre groupe de recherche (groupe TomOptUS). Le Centre d’imagerie moléculaire de Sherbrooke dispose d’un appareil pour imagerie optique sur petit animal développé par la compagnie Quidd, soit le QOS (Quidd Optical imaging System). Cet appareil est utilisé par des biologistes et chercheurs pour diverses études précliniques sur modèles animaux (souris) de maladies humaines comme le cancer. Le QOS est entièrement contrôlé par ordinateur à l’aide d’un logiciel sophistiqué (le QOSoft) qui permet d’obtenir des images en fluorescence et en bioluminescence. Il est toutefois limité en ne permettant d’acquérir que des images planaires de la lumière sortant d’un animal ; il ne permet pas la tomographie, à savoir obtenir des images tridimensionnelles (3D) des sources fluorescentes ou bioluminescentes situées en profondeur à l’intérieur de l’animal. Bien que le QOS offre une grande flexibilité en terme d’angle d’acquisition d’images autour de l’animal avec sa caméra montée sur un bras rotatif, il a une sensibilité limitée pour de l’imagerie en profondeur, notamment parce qu’il fonctionne en mode épiillumination (détection de la lumière du même côté que l’injection de la lumière excitatrice dans l’animal) et aussi à cause de la sensibilité limitée de sa caméra. Afin d’augmenter les capacités tomographiques et la sensibilité du QOS, ainsi que le contraste des images qu’il fournit, le présent projet propose des développements logiciels intégrés au QOSoft. Ces ajouts logiciels au niveau du contrôle d’instrumentation et de l’interface graphique permettent d’intégrer une caméra EMCCD à ultra-haute sensibilité et ultra-faible bruit pour remplacer la caméra CCD refroidie existante ainsi qu’un module d’illumination laser rotatif. Ce module d’illumination, développé par le groupe TomOptUS, permet l’imagerie en mode transillumination ainsi que toutes les configurations intermédiaires jusqu’à l’épi-illumination. Ce module permet en outre d’injecter une densité de puissance lumineuse supérieure à celle possible avec la configuration actuelle du QOS. Le QOS et son logiciel mis à jour avec les ajouts faisant l’objet du présent projet sont validés par des expériences de fluorescence et de bioluminescence sur fantômes et animaux vivants.

Page generated in 0.0503 seconds