• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 290
  • 20
  • 20
  • 2
  • 1
  • 1
  • Tagged with
  • 334
  • 260
  • 255
  • 229
  • 208
  • 153
  • 143
  • 119
  • 107
  • 72
  • 66
  • 58
  • 50
  • 47
  • 46
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
171

Expans?o r?pida maxilar com parafuso convencional e limitador posterior em pacientes com fissura transforame incisivo : altera??es verticais e ?ntero-posteriores

Lanes, Michel Azevedo 14 December 2006 (has links)
Made available in DSpace on 2015-04-14T13:29:58Z (GMT). No. of bitstreams: 1 386491.pdf: 18791773 bytes, checksum: 23dd3e96c1894b6bf14e79ed56a61116 (MD5) Previous issue date: 2006-12-14 / O objetivo deste estudo foi avaliar e comparar os efeitos da expans?o r?pida maxilar (ERM) em pacientes com fissura de l?bio e palato, utilizando disjuntor de Haas modificado com dois diferentes tipos de parafusos expansores. A amostra constituiu-se de 31 indiv?duos portadores de fissura transforame incisivo com idade m?dia de 10,7 anos, que apresentavam atresia maxilar na regi?o anterior e rela??o transversal posterior correta. Destes, 17 pacientes foram submetidos a ERM com parafuso limitador posterior (Grupo LP) e 14 com parafuso convencional (Grupo C), sendo avaliadas telerradiografias de perfil no per?odo pr?expans?o (T1), p?s-expans?o (T2), e seis meses p?s-expans?o (T3). Atrav?s do teste t-student e teste de Friedman (p≤0,05) verificou-se que em ambos os Grupos a maxila movimentou-se para baixo, no Grupo LP tamb?m para frente, no per?odo T2 e mantendo-se em T3. A movimenta??o mandibular foi semelhante entre os Grupos, havendo um posicionamento para baixo e para posterior em T2 retornando para anterior em T3. Os incisivos superiores nos Grupos LP e C extru?ram e no Grupo LP sofreram vestibulariza??o no per?odo de T2, mantendose em T3. Os molares superiores no Grupo Convencional sofreram extrus?o em T2 e retornaram a posi??o inicial em T3 e houve uma abertura do plano oclusal no Grupo Convencional, que foi reduzida em T3. Na avalia??o do perfil observou-se uma maior proje??o dos tecidos moles para anterior no Grupo LP.
172

An?lise local e sist?mica das rea??es tissulares a diferentes materiais utilizados em pulpotomias : estudo em ratos

Follmann, Carina Staudt 31 August 2011 (has links)
Made available in DSpace on 2015-04-14T13:30:02Z (GMT). No. of bitstreams: 1 434141.pdf: 4096445 bytes, checksum: 46ea01752aceb50c79baf98a79715628 (MD5) Previous issue date: 2011-08-31 / Introdu??o : O objetivo deste estudo foi avaliar, em ratos, a rea??o do tecido conjuntivo subcut?neo, e dos ?rg?os f?gado e rim, a materiais utilizados em pulpotomias: agregado tri?xido mineral (MTA), pasta de hidr?xido de c?lcio (HC) e formocresol (FC). M?todos: Tubos de polietileno vazios (grupo controle) e contendo os materiais de teste foram implantados no tecido subcut?neo de 46 ratos. Ap?s 7 e 21 dias, as observa??es no dorso foram feitas para altera??es inflamat?rias, condensa??o fibrosa, forma??o de abscesso e corpo estranho e, no f?gado e rim, foram avaliadas esteatose, apoptose, inflama??o, altera??es vasculares e hipercelularidade. Compara??es entre os grupos e per?odos de tempo foram feitas usando o teste de Kruskal-Wallis, Post-hoc e Mann-Whitney. Resultados: Os grupos MTA e HC mostraram um comportamento semelhante ao do grupo controle, nas altera??es inflamat?rias em 21 dias, ao contr?rio do grupo FC, o qual apresentou diferen?a estatisticamente significante em rela??o aos outros grupos. No grupo FC, n?o houve forma??o de c?psula fribrosa e houve forma??o de abscesso, em 21 dias. Em todos grupos, altera??es no f?gado e rim foram observadas. Conclus?o: Os grupos MTA e HC mostraram um comportamento similar em todos os eventos analisados. O grupo FC apresentou resultados n?o favor?veis. Foram observadas altera??es tissulares no f?gado e rim.
173

Compara??o da rugosidade ap?s abras?o por escova??o e da microdureza entre resinas compostas nanoparticuladas e microh?brida

Rosa, Rog?rio Sim?es 11 December 2006 (has links)
Made available in DSpace on 2015-04-14T13:30:02Z (GMT). No. of bitstreams: 1 386619.pdf: 4143713 bytes, checksum: 264c046972f7bb6da411606f1d2ba903 (MD5) Previous issue date: 2006-12-11 / O objetivo deste estudo in vitro foi avaliar a rugosidade ap?s abras?o por escova??o de corpo triplo e a microdureza Vickers de resinas compostas para uso direto com diferentes tamanhos de part?culas de carga inorg?nica, como a microh?brida Z250 e as nanoparticuladas Z350 e Supreme XT, de mesma marca comercial (3M ESPE, St Paul, Minessota, EUA). Seis corpos-de-prova (n=6) foram confeccionados para cada resina composta (Supreme XT, Z250 e Z350) e submetidos, na seq??ncia, a cada per?odo simulado de escova??o (controle, 6 meses, 1 ano e 2 anos). Foram realizadas 3 leituras de rugosidade de superf?cie Ra (μm) em cada amostra ap?s cada simula??o (total=216). Foi confeccionado 1 corpode- prova representativo de cada per?odo simulado de escova??o para cada resina composta (total=12), a fim de que fosse observado em MEV. Os valores m?dios m?nimos e m?ximos obtidos foram, respectivamente, de 0,14 μm (controle) para a resina Z350 e 0,21 μm (1 ano) para a resina Z250. Foi aplicada a an?lise de vari?ncia, seguida do teste de Tukey ( =0,05) e constatou-se que n?o houve diferen?a estatisticamente significante entre os grupos. A fim de avaliar a rugosidade em rela??o ao tempo e ao tipo de resina composta testada foi aplicado o modelo linear geral, seguido do teste de Tukey ( =0,05). Observou-se uma diferen?a estatisticamente significante da rugosidade no per?odo controle (0,15 μm) em rela??o ao per?odo de 1 ano (0,19 μm), com rela??o ao tipo de resina, ambas nanoparticuladas (0,16 μm) apresentaram-se significativamente menos rugosas que a microh?brida (0,19 μm). Os aspectos morfol?gicos superficiais obtidos em MEV mostram que houve padr?es semelhantes de desgaste entre as resinas compostas nos grupos controle. Ap?s os per?odos simulados de escova??o de 6 meses, 1 ano e 2 anos, observou-se uma surperf?cie mais uniforme para as resinas compostas nanoparticuladas em rela??o ? microh?brida. Para a microdureza Vickers, 5 amostras para cada resina composta foram confeccionadas (n=5). As m?dias (VHN) foram: Z250 74,44; Z350 73,87; XT 78,28. Ap?s an?lise de vari?ncia, observou-se que n?o houve diferen?a significante entre elas. Baseado nos resultados, concluiu-se que as resinas compostas nanoparticuladas (Z350, Supreme XT) obtiveram comportamento similar ? microh?brida (Z250) quanto ? microdureza Vickers, por?m, se apresentaram menos rugosas ap?s a abras?o por escova??o.
174

Retra??o de caninos superiores com molas fechadas de n?quel-tit?nio e el?sticos em cadeia

Pinto, Paulo Rog?rio de Oliveira 17 February 2007 (has links)
Made available in DSpace on 2015-04-14T13:30:08Z (GMT). No. of bitstreams: 1 386789.pdf: 11944950 bytes, checksum: 1e6a2354c67959fe7fd27a0c27bd0e49 (MD5) Previous issue date: 2007-02-17 / O objetivo deste estudo foi avaliar o fechamento dos espa?os na retra??o dos caninos permanentes superiores com dois m?todos distintos (el?sticos em cadeia e molas fechadas de n?quel-tit?nio) determinando: a velocidade m?dia do movimento dent?rio; a perda de ancoragem dos primeiros molares permanentes superiores; a influ?ncia do sexo e das extra??es de pr?-molares na velocidade m?dia de movimento ocorrida em cada sistema. A amostra constituiu-se de 15 pacientes portadores de maloclus?o de Classe II divis?o 1 de Angle, com m?dia de idade de 16,3 anos +5,6 anos, sendo 8 do sexo masculino e 7 do feminino, onde 5 utilizaram aparelho extrabucal previamente e 10 foram submetidos a extra??o de primeiros pr?-molares superiores. A retra??o dos caninos superiores foi realizada com el?sticos em cadeia, na hemiarcada direita, e com molas de n?quel-tit?nio, na esquerda, com for?a de 150 g. A distaliza??o dos caninos foi avaliada at? esta ter sido completada ou num per?odo m?ximo de 5 reavalia??es. Em cada uma destas consultas, foi obtido modelo de gesso a partir de moldagens com alginato. A avalia??o da velocidade m?dia mensal do fechamento dos espa?os foi feita em 4 locais diferentes (3 entre canino e pr?-molar e 1 entre canino e molar) e a perda de ancoragem medida entre o primeiro molar permanente e o ponto mais medial da terceira ruga palatina nos modelos de gesso. Os resultados demonstraram maior velocidade na retra??o dos caninos com o emprego dos el?sticos em cadeia, n?o havendo diferen?a entre indiv?duos do sexo masculino e feminino e entre os pacientes que utilizaram aparelho extra-bucal e os submetidos a extra??es. Ocorreu perda de ancoragem com o uso dos dois m?todos de retra??o, por?m n?o houve diferen?a significativa entre os dois sistemas para pacientes do sexo masculino e feminino. J? em rela??o ? compara??o entre pacientes que utilizaram AEB e os que tiveram os pr?-molares extra?dos, estes ?ltimos apresentaram maior perda de ancoragem com o uso dos el?sticos em cadeia.
175

Avalia??o in vitro da citotoxicidade celular do cimento de ion?mero de vidro modificado por carbonato de c?lcio de conchas marinhas

Giacomelli, ?dio 12 March 2012 (has links)
Made available in DSpace on 2015-04-14T13:30:08Z (GMT). No. of bitstreams: 1 437942.pdf: 14499337 bytes, checksum: 95040a95e0a346b6d9760a8fda191ce6 (MD5) Previous issue date: 2012-03-12 / This study aimed to evaluate the cytotoxicity and bioactivity of the glass ionomer cement modified with calcium carbonate shells. For testing cell toxicity was using Saccharomyces cerevisiae as a model organism. The induction of cytotoxicity was evaluated by two different tests using wild-type strain FF18733 of S. cerevisiae: (1) yeast cell survival and (2) formation of petite colonies (respiratory mutants). For tests of bioactivity was evaluated weight change of samples and analysis of hydroxyapatite deposition by SEM and EDS after immersion in simulated blood plasma. The results of survival tests showed that different concentrations of calcium carbonate added to the GIC (1%, 5% and 10% by weight) induced a slight loss of cell viability in S. cerevisiae in relation to the negative control, but it was not enough to be considered as a significant induction of toxicity. In relation to the petite colonies, there was no induction of mutants respiratory formation in any of the concentrations tested, indicating that the GIC did not induce altered oxidative stress in cells of S. cerevisiae. In the evaluation of bioactivity, the results showed that after immersion all groups tested showed a decrease in weight of the samples, which can be attributed to the dissolution of glass ionomer cement. In the fourth week of immersion there was a significant variation in the average percentage of weight for all groups. The SEM analysis showed a slight deposition of hydroxyapatite on the surface of the groups with the addition of powdered shells compared to the control group. / Este estudo teve como objetivo avaliar a citotoxicidade e bioatividade do cimento de ion?mero de vidro modificado com carbonato de c?lcio de conchas. Para os testes de toxicidade celular foi utilizando a Saccharomyces cerevisiae como organismo modelo. A indu??o de citotoxicidade foi avaliada por dois testes diferentes usando a S. Cerevisiae cepa selvagem wild-type FF18733: (1) a sobreviv?ncia da c?lula de levedura e (2) forma??o de col?nias petite (mutantes respirat?rios). Para os testes de bioatividade foi avaliada a varia??o de peso das amostras e an?lise de deposi??o de hidroxiapatita pela MEV e EDS ap?s imers?o em solu??o simuladora de plasma sang??neo. Os resultados dos testes de sobreviv?ncia mostraram que as diferentes concentra??es de carbonato de c?lcio adicionado ao CIV (1%, 5% e 10% em peso) induziram uma ligeira perda de viabilidade celular em S. cerevisiae em rela??o ao controle negativo, por?m n?o foi o suficiente para ser considerado como uma indu??o de toxicidade significativa. Em rela??o ?s col?nias petite, n?o foi observada a indu??o de forma??o de mutantes respirat?rios em qualquer uma das concentra??es testadas, indicando que o CIV modificado n?o induziu estresse oxidativo em c?lulas de S. cerevisiae. Na avalia??o da bioatividade, os resultados mostraram que ap?s a imers?o todos os grupos testados apresentaram uma diminui??o no peso das amostras, que pode ser atribu?do ? dissolu??o do cimento de ion?mero de vidro. Na quarta semana de imers?o houve uma varia??o significativa na percentual m?dio de peso para todos os grupos. A an?lise de MEV mostrou uma ligeira deposi??o de hidroxiapatita sobre a superf?cie dos grupos com a adi??o de p? de conchas em compara??o ao grupo controle.
176

An?lise da influ?ncia da placa de avan?o mandibular no bruxismo noturno atrav?s da polissonografia, BiteStrip? e question?rio de avalia??o do sono

Saueressig, Aline Cristina 23 January 2012 (has links)
Made available in DSpace on 2015-04-14T13:30:09Z (GMT). No. of bitstreams: 1 437628.pdf: 1858725 bytes, checksum: 5066f4507a95d98a5fb8be0218529808 (MD5) Previous issue date: 2012-01-23 / The aim of this before-and-after study was to test the efficacy of the anterior mandibular positioning appliance in the treatment of sleep bruxism, through the comparison among the polysomnography and the BiteStrip? results, and the answers of the Sleep Assessment Questionnaire (SAQ) before and after the use of this appliance. Eighteen patients with bruxism, at the average age of 39,9 years old (SD 12,98) were assessed before and after the application of the anterior mandibular positioning appliance. Therefore, bruxism diagnosis was made through the clinical evaluation, the polysomnography and the use of BiteStrip?, and the sleep diagnosis was made through the answers of SAQ. After three month, the subjects made again polysomnography, used the Bitestrip? and answered the SAQ to evaluate if there was any improvement of the bruxism and, consequently, of the sleep. To be considered for bruxism in the polysomnography, the examination should present 4.5 bruxism episodes per hour of sleep or 25 bruxism bursts per hour of sleep, plus an episode of gnashing of teeth / hour of sleep in the polysomnography. The others methods already have their own evaluation scales. Besides, the effects that the stomatognathic system can suffer by the use of this kind of appliance were analyzed. There was a significative improvement in the sleep bruxism and in the sleep, beyond a direct relation among polysomnography, BiteStrip? and the SAQ. In the stomatognathic system, there were less joint sounds and no significative side effects. So, the anterior mandibular positioning appliance has a positive effect in sleep bruxism and doesn't cause significative side effects in the stomatognathic system in a three month period. Was made an initial validation of the method to diagnose bruxism BiteStrip ? by comparing the results of the same with polysomnography. The Kappa index showed that there was high agreement between the two diagnostic methods. Through the test of sensitivity and specificity, one may suggest that the BiteStrip ? has high sensitivity (84.21%) and high specificity (100%) in the range of 95% compared with polysomnography. / Foi realizado um trabalho do tipo experimental antes-e-depois com o objetivo de avaliar a efic?cia do aparelho de avan?o mandibular no tratamento contra o bruxismo noturno, atrav?s da compara??o dos resultados nos exames polissonogr?ficos, do uso do BiteStrip? e das respostas do Question?rio de Avalia??o do Sono (QAS) antes e depois da utiliza??o do aparelho. O BiteStrip? foi usado associado a polissonografia. Foram avaliados 19 indiv?duos brux?manos com idade m?dia de 39,9 anos (DP 12,98) antes e depois do uso da placa de avan?o mandibular. Foi, ent?o, realizado diagn?stico de bruxismo atrav?s do exame cl?nico, da polissonografia e do uso do dispositivo BiteStrip? e diagn?stico do sono atrav?s do QAS antes do uso da placa. Ap?s tr?s meses, os indiv?duos novamente, fizeram polissonografia utilizaram o BiteStrip? e responderam o QAS para avaliar se houve melhora no bruxismo e, conseq?entemente, no sono. Para ser considerado bruxismo, o exame devia apresentar 4,5 epis?diosde bruxismo por hora de sono ou 25 explos?es de bruxismo por hora de sono. Ambos os outros dois m?todos j? t?m sua escala de avalia??o. Al?m disso, foram analisados os efeitos que esse tipo de placa pode causar no sistema estomatogn?tico. Houve uma melhora significativa no bruxismo noturno e no sono, al?m de uma rela??o direta entre a polissonografia, o BiteStrip? e o QAS. No sistema estomatogn?tico, houve uma diminui??o significativa nos ru?dos articulares e n?o houve nenhum efeito colateral significativo. Portanto, a placa de avan?o mandibular teve um efeito positivo no bruxismo noturno e n?o provocou efeitos colaterais significantes no sistema estomatogn?tico num per?odo de tr?s meses. Al?m disso, foi realizado foi realizado valida??o inicial do BiteStrip?, comparando esse com a polissonografia. Houve uma grande concord?ncia segundo ao ?ndice Kappa, com alta especificidade (100%) e alta sensibilidade (84,21%).
177

Efeito do ultrassom na resist?ncia de uni?o de cimentos resinosos autoadesivos ? dentina

Silva, Diego Fabris Ferreira da 02 March 2012 (has links)
Made available in DSpace on 2015-04-14T13:30:10Z (GMT). No. of bitstreams: 1 438292.pdf: 353384 bytes, checksum: e966b89cb4618df13c2f46329c3c7c3f (MD5) Previous issue date: 2012-03-02 / The aim of this study was to evaluate the influence of ultrasonic application on bond strength of self-adhesives resin cements to dentin. Twenty-four third molars were randomly divided into 4 groups (n=6/group): G1 - Rely X Unicem; G2 Maxcem Elite; G3 RelyX Unicem and ultrasonic application; G4 Maxcem Elite and ultrasonic application. Composite resin blocks were luted to flat dentin with a load of 500 g for 2 min, followed by light polymerization in G1 and G2. In G3 and G4, the ultrasonic device was applied for 20 s on the composite resin block, followed by 500 g load for 1 min and 40 s, and light polymerization. After storage in distilled water at 37?C for 24 h, six tooth/resin sets were cut parallel to the long axis of the tooth, in the x and y directions, with a section of about 0.8 mm2. Twenty-four specimens were obtained to each group, and submitted to microtensile bond strength (μTBS) test in an universal testing machine at 0,5 mm/min crosshead speed. According to two-way ANOVA, type of cement factor (p=0.000) and type of luting factor (o=0.002) were significant. The interaction was not significant (p=0676). According to student-t test (α=0.05), the μTBS mean with ultrasonic application (13.74 MPa) was statistically higher than without this treatment (10.57 MPa). The μTBS mean of RelyX Unicem (13.95 MPa) was statistically higher than Maxcem Elite (10.36 MPa). The ultrasonic application increased the μTBS of the RelyX Unicem and Maxcem Elite to dentin. / O objetivo desse estudo foi avaliar a influ?ncia da vibra??o ultrass?nica na resist?ncia de uni?o de cimentos resinosos autoadesivos ? dentina. Vinte e quatro dentes terceiros molares foram divididos aleatoriamente em quatro grupos (n=6/grupo): G1 RelyX Unicem; G2 Maxcem Elite; G3 RelyX Unicem com vibra??o ultrass?nica; G4 Maxcem Elite com vibra??o ultrass?nica. Blocos de resina composta foram cimentados sobre dentina plana com carga de 500 g por 2 min, seguido de fotoativa??o nos G1 e G2. Em G3 e G4, a vibra??o ultrass?nica foi aplicada por 20 s sobre o bloco de resina composta, seguido de carga de 500 g por 1 min e 40 s e fotoativa??o. Ap?s armazenagem em ?gua destilada a 37? C por 24 h, seis conjuntos dente/resina foram cortados paralelamente ao longo eixo do dente, nos sentidos x e y, com sec??o de aproximadamente 0,8 mm2. Foram obtidos 24 corpos de prova para cada grupo, sendo ent?o submetidos ao teste de resist?ncia ? microtra??o (Rμt) em m?quina de ensaio universal com velocidade de 0,5 mm/min. De acordo com An?lise de Vari?ncia Fatorial, as vari?veis tipo de cimento resinoso (p=0,000) e tipo de cimenta??o (p=0,002) foram significativas. A intera??o das duas var?veis n?o foi significativa (p=0,676). De acordo com o teste t-student (α=0,05) a m?dia de Rμt com uso da vibra??o ultrass?nica (13,74 MPa) foi estatisticamente superior sem aplica??o da vibra??o ultrass?nica (10,57 MPa)). A m?dia de Rμt do RelyX Unicem (13,95 MPa) foi estatisticamente superior ao Maxcem Elite (10,36 MPa). A vibra??o ultrass?nica aumentou a resist?ncia de uni?o dos cimentos resinosos autoadesivos RelyX Unicem e Maxcem Elite ? dentina.
178

Avalia??o da resist?ncia ? uni?o dentin?ria entre tratamento ultra-s?nico e alta rota??o na interface dente/material restaurador

Conde, Alexandre 08 January 2007 (has links)
Made available in DSpace on 2015-04-14T13:30:14Z (GMT). No. of bitstreams: 1 387554.pdf: 6424305 bytes, checksum: eede53bc1323d5be8d0e3d939fde81ca (MD5) Previous issue date: 2007-01-08 / Dezessete terceiros molares h?gidos extra?dos foram utilizados com objetivo de avaliar a dentina quanto: resist?ncia ? uni?o por microtra??o (μTBS) com resina composta (CR) Z250 e adesivo Single Bond 2 (3M); aspecto pr?vio ao tratamento adesivo (APTA); uni?o adesiva (UA); tipo de fratura por microscopia eletr?nica de varredura (MEV) e espectroscopia por dispers?o de energia (EDS) comparando o tratamento com ponta diamantada KGSorensen (PD) e haste ultra-s?nica CVDentUS (UT) com (c/a) ou sem (s/a) condicionamento ?cido. Quatro grupos (n=40) divididos conforme processamento dentin?rio (PDs/a; PDc/a; UTs/a; UTc/a) foram restaurados, inclu?dos em resina acr?lica autopolimeriz?vel e transformados em pequenas barras por m?quina de corte seriado para posterior ensaio de μTBS em m?quina universal EMIC DL-2000 (0,5 mm/min). As amostras foram analisadas por MEV e EDS para classifica??o de fratura, UA e APTA. Os testes estat?sticos foram: Kolmogorov-Smirnov; An?lise de Vari?ncia fatorial; Tukey e Exato de Fisher (p≤0,05). As falhas foram classificadas em: Coesiva em dentina (CD); coesiva em CR (CM); interfacial coesiva na base ou topo de camada h?brida (CBT); interfacial coesiva adesiva (CA); mista (M); interfacial no smear layer (S). Os resultados mostraram (grupo, m?dia μTBS em MPa - desvio padr?o): (UTc/a, 45,31-8,16); (PDc/a, 34,04-9,29); (UTs/a, 15,17-3,71); (PDs/a, 9,86-3,80). O m?todo PD est? associado ? CBT e o m?todo UT ?s CA e CM, c/a est? associado ?s CBT e CM e s/a ? S. O APTA mostrou: PDs/a total obstru??o dos canal?culos dentin?rios (cd); UTs/a parcial desobstru??o dos cd e aspecto irregular de superf?cie; PDc/a completa desobstru??o dos cd; UTc/a completa desobstru??o dos cd e aspecto irregular de superf?cie. Em PDs/a ocorreu camada h?brida retil?nea sem penetra??es de tags (PT); UTs/a, curvil?nea com algumas PT; PDc/a, retil?nea com PT; UTc/a, curvil?nea com PT. Concluiu-se que a associa??o do tratamento UTc/a promove valores maiores de μTBS. Existe associa??o entre falha CBT com o m?todo PD, falhas CA e CM com o m?todo UT, falhas CBT e CM com o m?todo c/a e falha S com o m?todo s/a. As falhas que ofereceram maior resist?ncia para seu rompimento s?o, em ordem decrescente: CD; CM; CBT; CA; M; S
179

Distribui??o das tens?es em tr?s tipos diferentes de pr?teses fixas implanto-suportadas tipo protocolo: estudo pelo m?todo dos elementos finitos

Coelho, Luiz Felipe Butzke 25 January 2012 (has links)
Made available in DSpace on 2015-04-14T13:30:15Z (GMT). No. of bitstreams: 1 442212.pdf: 8469172 bytes, checksum: e497ae0c16d8dee2df60b87814113982 (MD5) Previous issue date: 2012-01-25 / The objective of this study was a qualitative evaluation and comparison by means of finite element analysis of the tension distribution generated by a simulated loading in 3D models of implants, abutments, fixed protocol prosthesis and mandibular bone tissues. The analysis were carried out in 3 tridimensional models: a) model A, simulating a temporary full-resin protocol prosthesis, b) model B, simulating a metal-resin protocol prosthesis, and c) model C, simulating a porcelain-fused-tometal protocol prosthesis. The results from our study suggested that models A, B, and C presented different biomechanical performances when submitted to the same mechanical load. Model A was the one which presented the worst biomechanical performance in the analyzed models. / O objetivo deste estudo foi avaliar e comparar de maneira qualitativa, por meio da an?lise por elementos finitos, a distribui??o das tens?es geradas por cargas simuladas em modelos 3D de implantes, pilares, pr?teses fixas tipo protocolo e tecido ?sseo mandibular. As an?lises foram realizadas em tr?s modelos tridimensionais: modelo A simulando um protocolo provis?rio de acr?lico, modelo B simulando uma pr?tese tipo protocolo metalopl?stico e modelo C, metalocer?mico. O carregamento oclusal foi padronizado em 100 N e aplicado no extremo distal do cantilever lado direito. Os resultados obtidos sugeriram que os modelos A, B e C apresentaram comportamentos biomec?nicos diferentes quando exigidos pelo mesmo esfor?o mec?nico. O modelo A (provis?rio de acr?lico) foi o que apresentou o pior comportamento biomec?nico nas estruturas analisadas.
180

Avalia??o dos efeitos do aparelho extra-oral tra??o cervical na m? oclus?o de classe ll divis?o 1 de angle, antes e durante o pico decrescimento puberal

Araujo, Vanessa Pereira de 15 December 2005 (has links)
Made available in DSpace on 2015-04-14T13:30:16Z (GMT). No. of bitstreams: 1 342815.pdf: 14513419 bytes, checksum: 15f05edd641e491b6011fc6c7b1ce6e9 (MD5) Previous issue date: 2005-12-15 / Este estudo avaliou as altera??es dentoesquel?ticas ocorridas em 42 indiv?duos tratados com aparelho extra-oral tra??o cervical por 7 meses. Todos os pacientes eram brasileiros, brancos, saud?veis, portadores de m? oclus?o de Classe II divis?o 1 de Angle, com idade variando entre 8 a 15 anos, e foram divididos em dois grupos, de acordo com a idade esquel?tica: E1 (experimental precoce) composto por 20 indiv?duos (8 do g?nero feminino e 12 do masculino) e E2 (experimental tardio) formado por 22 indiv?duos (16 do g?nero feminino e 6 do masculino). O grupo controle (C1 e C2) envolveu 30 indiv?duos Classe I de Angle (16 do g?nero feminino e 14 do masculino), tratados ortodonticamente apenas por procedimentos como manuten??o ou recupera??o de espa?os e desgastes interproximais, pareados quanto ? idade ?ssea ao grupo experimental. Para tal avalia??o, utilizaram-se telerradiografias de perfil em T1 (inicial) e T2 (reestudo) e radiografias de m?o e punho em T1 (inicial). A an?lise estat?stica foi realizada por meio do teste t de Student, com n?vel de signific?ncia de 5%. Os resultados evidenciaram tend?ncia de restri??o do crescimento ?ntero-posterior maxilar e de giro maxilar no sentido hor?rio para a idade precoce (p>0,05). Para o grupo tardio, houve apenas tend?ncia de rota??o maxilar hor?ria (p>0,05). Ocorreu estabilidade da posi??o mandibular tanto para os indiv?duos do grupo E1 (precoce) quanto para os do E2 (tardio) (p>0,05). Verificou-se melhora na rela??o maxilomandibular, para o grupo precoce (p<0,01) e para o grupo tardio (p>0,05). Houve inclina??o do primeiro molar superior para distal (p<0,01), sem efeito extrusivo e n?o houve altera??o da posi??o do incisivo central superior, em ambos os grupos, precoce e tardio. N?o se constatou diferen?a significativa entre o tratamento em idades precoce ou tardia

Page generated in 0.0325 seconds