• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 967
  • 33
  • 32
  • 32
  • 32
  • 21
  • 11
  • 11
  • 6
  • 5
  • 3
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 981
  • 600
  • 426
  • 324
  • 258
  • 231
  • 196
  • 144
  • 127
  • 96
  • 86
  • 85
  • 83
  • 75
  • 74
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
151

Estudo comparativo da eficacia de dois adesivos dentinarios e um cimento de ionomero de vidro empregados na adesão do amalgama a dentina /

Huhtala, Maria Filomena Rocha Lima. January 1995 (has links)
Orientador: Jose Benedicto de Mello / Banca: Celso Luiz de Angelis Porto / Banca: Maria Amélia Maximo de Araujo / Resumo: Este estudo teve como objetivo realizar a avaliação ln vitro, da resistência da adesão do amálgama, Dispersalloy, à dentina, quando dois adesivos dentinários, Amalgambond Plus (AP) e Scotchbond Multi Purpose (SMP) e um cimento de ionômero de vidro, Vitrebond (V), foram empregados no tratamento desta superfície dentinária. Trinta dentes terceiros molares humanos recém-extraídos, foram seccionados em metades vestibular e lingual, que foram incluídas em blocos de resina acrílica, de modo a terem suas superfícies dentinárias superficiais expostas com lixas de granulação crescente: 100, 180, 400 e 600; sob constante refrigeração de água. Sobre estas superfícies dentinárias foram fixados tubos de polietileno com 3 mm de diâmetro e 5 mm de altura, estabilizados com uma matriz de teflon e alumínio, permitindo assim a condensação do amálgama, imediatamente após o tratamento com um dos sistemas adesivos: AP, SMP,V. Após a confecção dos cilindros de amálgama, as amostras foram estocadas à 37º C por 24 horas, antes de serem submetidas aos testes mecânicos de cisalhamento em máquina Instron a uma velocidade de 0,5 mm/minuto. Os resultados da força requerida para o cisalhamento dos cilindros de amálgama foram expressos em MPa e as superfícies, dentinárias e de amálgama, observadas em estereomicroscopia, após a fratura. Os dados foram analisados através do modelo estatístico de análise de variância. A força média de adesão, quando como agente intermediário entre amálgama/ dentina, foi utilizado o AP, foi de 2,21 ± l ,5 MPa , quando o SMP de 0,33 ± 0,8 MPa e o V de 2,63 ± 1,66 MPa. O AP e o V foram considerados estatisticamente semelhantes (p>0,05) e diferentes do SMP (p<0,05). As fraturas foram predominantemente adesivas na interface amálgama/resina para o SMP (73,34%) e consideradas mistas, do amálgama/sistema adesivo, para o AP (80%) e para o V (93,36%) / Abstract: The purpose of this in vitro study was to determine the shear bond strengths of amalgam to dentin treated with the Amalgambond Plus (AP) and Scotchbond Multi Purpose (SMP) dentin adhesive systems and with the glass-ionomer cement, Vitrebond (V).The buccal and lingual superficial dentin surfaces of thirty extracted human third molars were exposed by wet grinding on 600-grit silicon carbide and the bonding areas demarcated with plastic band matrices (3mm/5umm),fixed in position by the means of a rigid aluminium/teflon mold. The demarcated dentin surfaces were treated with AP, SMP and V as directed by the manufacturers and freshly mixed Dispersalloy amalgam condensed into the plastic matrices. The specimens were then stored in 37°C for 24 hours. The matrices were removed; the shear bond tests performed in an Instron Universal Testing Machine at a cross-head speed of 0.5mm/sec.; and the results expressed in MPa. Some failures were examined in stereomicroscopy. The data were analysed by one-way analysis of variance, Mean failure loads and S.D, were: AP, 2,21 ± 1,5; SMP, 0,33±0,8 e V, 2,63± l,6. Tire shear bond strengths of AP vs V were not significantly different (p>0,05) and SMP was significantly different (p<0,05), Stereomicroscopic analysis demonstrated adhesive failures for SMP (7334%) at the resin/amalgam interface and mixed failures for AP (80%) and for V (933%) within both systems / Mestre
152

Efeito de um primer autocondicionante na resistência ao cisalhamento de bráquetes com compósito pré-incorporado / Effect of a self-etching primer on smear bond strength of adhesive precoated brackets

Julio Orrico de Aragão Pedra e Cal Neto 15 December 2005 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O uso de primers autocondicionantes e de bráquetes com compósito pré-incorporado tem sido apresentado como uma alternativa para a redução de passos clínicos. O propósito deste estudo foi avaliar o efeito de um primer autocondicionante (Transbond Plus Self-Etching Primer - SEP) na resistência ao cisalhamento de bráquetes com compósito pré-incorporado colados in vivo. A amostra consistiu de 92 dentes obtidos de 23 pacientes com indicação prévia de extração de 4 pré-molares. Os dentes foram divididos em 4 grupos, sendo os bráquetes colados pelo mesmo operador, alternando os quadrantes em cada paciente: Grupo 1 (controle) - Ácido fosfórico à 37% + primer (Transbond XT Primer) + compósito (Transbond XT Adhesive Paste) + bráquete convencional; Grupo 2 - Ácido fosfórico à 37% + primer + bráquete com compósito pré-incorporado; Grupo 3 SEP + compósito + bráquete convencional; Grupo 4 - SEP + bráquete com compósito pré-incorporado. Após 30 dias os pré-molares foram extraídos, sendo submetidos ao teste de resistência ao cisalhamento através da uma Máquina de Ensaios Universal, com velocidade de 0,5mm/min. Os dados obtidos pelos grupos foram analisados com 2-way ANOVA (p<0,05). As forças médias e desvios padrão obtidos foram os seguintes: Grupo 1 = 11,35 (2,36) MPa; Grupo 2 = 9,77 (2,49) MPa; Grupo 3 = 10,89 (2,60) MPa; e Grupo 4 = 10,16 (2,75) MPa. Não foi observada diferença significativa entre o uso do SEP e o de condicionador e primer tradicionais (p = 0,948). De qualquer modo, diferenças significativas na força de adesão foram observadas quando utilizados bráquetes com compósito pré-incorporado (p = 0,032). Pode ser concluído que a combinação do primer autocondicionante com o bráquete com compósito pré-incorporado apresentou valores de força de adesão adequados, sendo promissora para uso clínico. / The use of self-etching primers and precoated brackets are presented as alternatives to shorten the clinical bonding steps. The aim of this study was to evaluate the influence of a self-etching primer - SEP (Transbond Plus SEP, 3M Unitek) on shear bond strength of adhesive uncoated and precoated Victory brackets (3M Unitek). The sample group consisted of 23 patients with 4 premolars each one, equally divided in four different groups according to the bracket and enamel preparation. Brackets were bonded in vivo, by the same operator, using a split mouth random technique: Group 1- 37% Phosphoric acid + primer + composite + conventional Victory bracket; Group 2- 37% Phosphoric acid + primer + precoated Victory bracket; Group 3- SEP + composite + conventional bracket; Group 4- SEP + precoated bracket. After 30 days premolars were extracted for orthodontic reasons, and a Universal Testing Machine was used to apply an occlusal shear force directly to the enamel-bracket interface at a speed of 0.5 mm/min. Mean results and standard deviation for the groups were: Group 1 = 11,35 (2,36) MPa; Group 2 = 9,77 (2,49) MPa; Group 3 = 10,89 (2,60) MPa; e Group 4 = 10,16 (2,75) MPa. The groups were compared using 2-way ANOVA. No difference was observed while a conventional etching and primer or self-etching primer was used (p = 0.948). But, it was indicated significant differences in bond strength between uncoated and precoated brackets (p = 0.032). However, it could be concluded that the self etching primer combined with adhesive precoated brackets showed adequate shear bond strength, and may be suitable for clinical use.
153

Estudo aleatório e controlado do uso clínico de um primer autocondicionante na colagem de bráquetes ortodônticos / Bond failure rates with a self-etching primer: a randomized controlled trial

Julio Orrico de Aragão Pedra e Cal Neto 27 January 2009 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O uso de primers autocondicionantes tem sido proposto como uma alternativa para a redução de passos clínicos. O objetivo deste estudo clínico aleatório e controlado foi avaliar a performance de um sistema autocondicionante (Transbond Plus Self-Etching Primer, 3M Unitek - SEP) comparado a um sistema multipasso convencional (Transbond XT, 3M Unitek - TBXT) de colagem ortodôntica, durante um período de 12 meses. Vinte e oito pacientes participaram deste estudo, sendo estes alocados aos grupos SEP ou TBXT de forma aleatória, através de randomização em bloco. Um total de 548 bráquetes metálicos (Micro-Arch, prescrição Alexander, GAC International, Bohemia, NY) foram colados com uso da pasta adesiva Transbond XT (3M Unitek), sendo todos os produtos manuseados de acordo com as recomendações dos fabricantes. Foram totalizados 276 bráquetes no grupo controle e 272 no segundo. Curvas de sobrevivência Kaplan-Meier e o teste log-rank (p<0,05) foram utilizados para comparar o percentual de falhas adesivas para as duas técnicas. Ao final do período foram verificadas trinta e duas falhas adesivas (bráquetes descolados), sendo 19 (6,98%) falhas quando utilizado o primer autocondicionante (SEP) e 13 (4,71%) quando usado o primer convencional (TBXT). Não houve diferença significante entre a sobrevivência dos bráquetes entre os dois grupos avaliados (log-rank test, p=0,311). Quando a influência de gênero do paciente, arco dentário e tipo dentário (anterior ou posterior) foram analisados, somente o tipo dentário foi achado significante. Bráquetes de dentes posteriores apresentaram uma maior probabilidade de falha adesiva que os colados em dentes anteriores (p=0,013) Os autores concluem que o primer autocondicionante pode ser utilizado para colagem direta de bráquetes ortodônticos sem que sua sobrevivência clínica seja afetada. / The use of self-etching primers is presented as an alternative to shorten the clinical bonding steps. The purpose of this clinical trial was to evaluate over a 12-month period the performance of a self-etching system (Transbond Plus SEP, 3M Unitek - SEP) compared with a conventional multi-step system (Transbond XT, 3M Unitek - TBXT). Twenty-eight randomly selected patients were included in this study, each being randomly assigned to TBXT or SEP group. A total of 548 brackets were bonded following the manufacturers instructions, using Transbond XT adhesive paste. The survival rate of brackets were estimated with Kaplan-Meier analysis. Bracket survival distributions with respect to bonding procedure, tooth location, dental arch and patient gender were compared with log-rank test. The failure rates of the TBXT and SEP group were 4.71 and 6.98 per cent respectively. No significant differences in the survival rate were observed between the bonding procedures (p=0.311). When the tooth location, dental arch and patient gender were analysed, only the tooth location was found to be significant. Posterior brackets were more likely to fail than the anterior brackets (p=0.013). Both systems had low bonding failure rates and can be considered adequate for orthodontic bonding needs.
154

Avaliação clínica dos efeitos da associação do peróxido de hidrogênio a 38% com o peróxido de carbamida a 10% /

Machado, Lucas Silveira. January 2013 (has links)
Orientador: Renato Herman Sundfeld / Banca: André Luiz Fraga Briso / Banca: Paulo Henrique dos Santos / Banca: Marcelo Giannini / Banca: Márcio Grama Hoeppner / Resumo: O objetivo deste estudo clínico foi avaliar os efeitos da associação de técnicas clareadoras com peróxido de hidrogênio (clareamento de consultório) e de carbamida (clareamento caseiro), na alteração de cor, sensibilidade dental, na morfologia e rugosidade superficial do esmalte dental. Fizeram parte dessa pesquisa clínica 21 voluntários, com faixa etária de 18-25 anos. Foram utilizados, de acordo com as especificações do fabricante, o produto clareador a base de peróxido de hidrogênio a 38% Opalescence Boost PF (Ultradent Products Inc., UT, EUA) e o a base de peróxido de carbamida a 10% Opalescence (Ultradent Products Inc., UT, EUA). O fator em estudo foi a "técnica clareadora" em 2 níveis: Técnica 1 (clareamento de consultório associado com clareamento caseiro) e Técnica 2 (apenas clareamento caseiro). Inicialmente, os voluntários tiveram suas hemi-arcadas superiores direita ou esquerda submetidas ao clareamento de consultório com 3 aplicações de 15 minutos cada de peróxido de hidrogênio a 38% ou placebo (Fase 1), respectivamente, caracterizando assim, um delineamento tipo split-mouth ou de boca dividida. Durante os 7 dias seguintes à Fase 1, os voluntários realizaram o clareamento caseiro utilizando o peróxido de carbamida a 10%, por 4 horas diárias (Fase 2) em ambos os lados; a Fase 1 e 2 foram repetidas por mais uma vez na semana seguinte. A mensuração da variável alteração de cor foi realizada nos incisivos e caninos superiores, pelo método visual (Vita Classical, Vita Zahnfabrik, Germany) e digital (Vita Easyshade, Vita Zahnfabrik, Germany), antes e após a Fase 1 e ao final do experimento; a variável sensibilidade foi analisada pelo método analógico visual; enquanto que as alterações da superfície de esmalte e... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The objective of this clinical study was to evaluate the association between two dental bleaching techniques - hydrogen peroxide bleaching (in-office bleaching) and carbamide peroxide (home bleaching) - and color change, dental sensitivity, morphology, and superficial roughness of dental enamel. Were performed two applications according to the manufacturer's specifications, one per week, of the in-office bleachingwith38% hydrogen peroxide. We applied the home bleaching technique for two weeks with 10% carbamide peroxide in a custom-made tray. The factor studied was the "bleaching technique" on 2 levels: Technique 1 (in-office bleaching associated with home bleaching) and Technique 2 (home bleaching only).The response variables were color change, dental sensitivity, morphology, and superficial roughness. According to a random draw, the volunteers had their maxillary right and left hemi arches submitted to in-office placebo treatment and to in-office bleaching, respectively (Phase 1), and at home bleaching (Phase 2) treatment for both hemi-arches, characterizing a split-mouth type of design. The color change was performed in the incisor and canine teeth by visual and digital evaluation before and after phase 1 and after the conclusion of each session of attendance. The dental sensitivity was assessed using the visual analogical method whereas the enamel surface changes and roughness were analyzed by electron microscopy (SEM) and by optical interferometry (IFM), through replicas clinically obtained based on central incisors before and after bleaching procedures. No differences were observed between the bleaching techniques for both the visual and digital analysis. There was a significant difference in the dental sensitivity... (Complete abstract click electronic access below) / Doutor
155

Avaliação in vitro da efetividade de dentifrícios de baixa concentração de fluoreto suplementados com fosfato /

Takeshita, Eliana Mitsue. January 2006 (has links)
Orientador: Kikue Takebayashi Sassaki / Banca: Marília Afonso Rabelo Buzalaf / Banca: Marines Nobre dos Santos Uchôa / Resumo: A redução da concentração de fluoreto (F) nos dentifrícios é importante para a prevenção da fluorose dental, entretanto, é necessário manter a mesma efetividade de um dentifrício de mercado (1100 mgF/g). O objetivo do presente trabalho foi avaliar in vitro se a suplementação com fosfato em dentifrícios com baixa concentração de F pode proporcionar eficácia semelhante a de um dentifrício padrão sobre a desmineralização do esmalte de dente bovino, utilizando modelo de ciclagem de pH. Blocos de esmalte selecionados foram submetidos a repetidas ciclagens de pH alternadas com tratamento diário com dentifrícios contendo 500 mgF/g e entre 0 e 3% de trimetafosfato de sódio (TMP); foram utilizados também um dentifrício sem adição de F e TMP (placebo) e um comercial (Crest, de 1100 mgF/g). Após as ciclagens foram determinadas a porcentagem de perda da microdureza de superfície, perda mineral (_Z) e conteúdo de F, cálcio (Ca) e fósforo (P) no esmalte. Foram utilizados testes paramétricos e não paramétricos e análise de correlação de Pearson para determinar diferenças e relação dose resposta entre os tratamentos. Os resultados mostraram que a adição de TMP (0,25-3,0%) a dentifrícios sem F causa uma diminuição na %SMH e na _Z, e quando adicionado a um dentifrício de 500 mgF/g o efeito final torna-se comparável a de um dentifrício de 1100 mgF/g. Observou-se também aumento na concentração de F na camada superficial da lesão com o aumento da concentração de TMP. Conclui-se que é possível reduzir a concentração de F a 500 mg/g e se obter uma ação comparável com a de um dentifrício comercial através da suplementação com fosfato sob a forma de TMP. / Abstract: The reduction of fluoride (F) concentration in dentifrices is important to prevent dental fluorosis, but it is necessary to maintain their effectiveness. The aim of this study was to evaluate, in vitro, whether the phosphate supplementation of a dentifrice with low F content would provide a similar effect when compared to a standard dentifrice. Bovine enamel demineralization in a pH cycling model was used. Enamel blocks were selected trough surface microhardness (SMH) and were subjected to a pH cycling during 7 days. The treatment was done twice daily for 1 min with dentifrice containing 500 mgF/g. The sodium trimetaphosphate (TMP) concentration varied from 0 up to 3%. For the control groups, a dentifrice without F and P and a "Gold Standard" dentifrice (1100 mgF/g) were used. After the pH cycling, the percentage change of surface microhardness (%SMH), mineral loss (_Z) and the assessment of F, calcium and phosphate in enamel were calculated. Parametrical and non-parametrical tests and Pearsonþs correlation analysis were used to determine difference (p<0.05) and dose-response relationship between treatments. The results showed that TMP addition (from 0.25 to 3%) to a dentifrice without F induces a reduction in %SMH and _Z. When this concentration of TMP is added to a dentifrice with 500 mg F/g the final effect is similar to a dentifrice with 1100 mgF/g (CrestÔ). Also, the results showed an increase in the F content in lesion surface layer with the increase of TMP concentration. It is concluded that it is possible reduce the F content to 500 mgF/g by supplementing with phosphate and obtain a similar action when compared to a market dentifrice. / Mestre
156

Avaliação das características do esmalte dental clareado por diferentes protocolos /

Almeida, Eran Nair Mesquita de January 2019 (has links)
Orientador: Alessandra Nara de Souza Rastelli / Resumo: O objetivo deste estudo in vitro foi avaliar a eficácia de diferentes técnicas de clareamento dental, através das análises de dureza e contéudo mineral do esmalte dental clareado. Diferentes protocolos foram testados após manchamento dos espécimes com (café), como segue: G1: Whiteness HP Maxx (FGM); G2: Whiteness HP Maxx (FGM) + LED Azul - Twin Flex Evolution (MMOptics); G3: Whiteness HP Maxx (FGM) + LED Violeta - Bright Max Whitening (MMOptics); G4: Peróxido de Hidrogênio a 10% (FGM); G5: Peróxido de Hidrogênio a 10% (FGM) + Led Violeta - Bright Max Whitening (MMOptics); G6: Peróxido de Carbamida a 22% (FGM); G7: Peróxido de Carbamida a 22% (FGM) + LED Violeta - Bright Max Whitening (MMOptics) e G8: LED Violeta - Bright Max Whitening (MMOptics). Foram obtidos oitenta (n=80) espécimes de (4x4x2mm) da face vestibular de incisivos bovinos, após foram seccionados ao meio em máquina de corte, separando cada espécime em duas metades, uma metade foi utilizada como espécime sem procedimento clareador (controle) e a outra metade como espécime com procedimento clareador (tratado). Foi realizada análise em profundidade no esmalte, afim de verificar as possíveis alterações na superficíe (S) e subsuperficie (P), assim, cento e sessenta (n=160) espécimes foram avaliados quanto microdureza Knoop (n =10) e espectroscopia Raman (n = 5). Os diferentes protocolos para clareamento dental foram aplicados de acordo com os fabricantes dos produtos e dos equipamentos. Os espécimes permaneceram em s... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The objective of this in vitro study was to evaluate the effectiveness of different dental bleaching techniques through microhardness analysis and mineral content of bleached dental enamel. Different protocols were tested after spotting the specimens with (coffee), as follows: G1: Whiteness HP Maxx (FGM); G2: Whiteness HP Maxx (FGM) + Blue LED - Twin Flex Evolution (MMOptics); G3: Whiteness HP Maxx (FGM) + Violet Led - Bright Max Whitening (MMOptics); G4: 10% Hydrogen Peroxide (FGM); G5: 10% Hydrogen Peroxide (FGM) + Violet Led - Bright Whitening (MMOptics); G6: 22% carbamide peroxide (FGM); G7: 22% Carbamide Peroxide (FGM) + LED Violet - Bright Max Whitening (MMOptics) and G8: Violet LED - Bright Max Whitening (MMOptics). Eighty (4x4x2mm) specimens were collected from the bovine incisal vestibular surface, after being sectioned in the cutting machine, separating each specimen into two halves, one half was used as a specimen without bleaching procedure (control) and the other half as a specimen with bleaching procedure (treated). To verify the possible changes in surface (S) and subsurface (P), one hundred and sixty (n = 160) specimens were evaluated for Knoop microhardness (n = 10) and Raman spectroscopy (n = 5). The different dental bleaching protocols were applied according to the manufacturers of the products and equipment. The specimens remain in artificial saliva at 37 ° C throughout the experiment period and are replaced weekly. Changes in bovine dental enamel were eva... (Complete abstract click electronic access below) / Mestre
157

Análise morfológica da matriz do esmalte de incisivos de ratos submetido à fluorose

Costa, Maria Renata Sales Nogueira 30 November 2000 (has links)
As amelogeninas representam o principal grupo de proteínas do esmalte e a sua retenção pós-transicional apresenta-se como um dos fatores relacionados à patogenia da fluorose dentária. O padrão de distribuição das amelogeninas, em dentes com fluorose, foi descrito por técnica imuno-histoquímica e o comprimento linear da matriz orgânica do esmalte foi determinado por análise morfométrica. Foram utilizados 15 ratos, divididos em três grupos e tratados com 100 ppm, sete ppm e com água deionizada, durante 42 dias. Os resultados obtidos por imunohistoquímica indicaram possíveis variações na exposição dos epítopos de amelogeninas, que foram evidenciadas de forma heterogênea. Os resultados da análise morfométrica permitiram a constatação de que não houve diferenças significantes entre os grupos tratados com 7ppm de fluoreto de sódio e com água deionizada ao longo da fase secretora da matriz, e que no grupo com fluorose induzida por 100ppm, o comprimento linear da matriz foi 300% maior, em relação aos outros grupos testados. Observou-se ainda que, a densidade óptica da matriz orgânica manteve-se mais densa e homogênea após o início da fase de maturação do esmalte. Concluiu-se que, frente à metodologia adotada, 100 ppm de fluoreto de sódio reservam a capacidade de reter as proteínas do esmalte ao longo da fase de maturação, onde deveriam ser clivadas e reabsorvidas, resultando em um padrão morfológico macroscópico de hipomineralização, característico da fluorose dentária. / Amelogenins represents the major dental enamel protein motif and its posttransitional retention comes as one of the main factors related to fluorosis pathogenesis. The amelogenins distribution pattern in fluorotic teeth was described by immunohistochemistry and the length of organic matrix was determined by morfometric analysis. Fifteen rats were divided in three groups and treated for 42 days with 100ppm sodium fluoride, 7ppm and with deionizaded water. The immunohistochemistry results displaied amelogenins in a by heterogeneous way, indicating possible variations in the proteins epitopes exposition. The results of morfometric analysis at matrix secretion allowed the verification of no significant differences betwen the group with 7ppm and with deionizaded water. In group with fluorosis induced by 100ppm, the matrix length was 300% longer, whem compared to the other tested groups. It was observed although, that matrix optical density stayed denser and homogeneous after the beginning of the maturation phase, indicating its post-transitional retention. It was ended, front to the adopted methodology, that 100 ppm of sodium fluoride reserves the capacity to retain the enamel proteins along the maturation phase, where they should be resorperd. The result is a hypomineralized pattern, characteristic of the dental fluorosis.
158

Resistência de união entre uma cerâmica e o esmalte de dente bovino, efetuada por diferentes sistemas adesivos e técnicas de cimentação / Bond strength between a ceramic and bovine tooth enamel, made by different adhesive systems and luting techniques

Sá, André Tomazini Gomes de 11 October 2011 (has links)
O objetivo no presente trabalho foi avaliar a resistência da união adesiva de uma cerâmica vítrea (IPS e.max Press) fixada sobre o esmalte de dentes bovinos. Empregaram-se dois métodos de cimentação um, com a fotoativação prévia do adesivo; outro, com a fotoativação simultânea do adesivo e do cimento compósito após a fixação do disco cerâmico, que tinha 5mm de diâmetro e 2mm de espessura. Pela combinação de dois sistemas adesivos fotopolimerizáveis (Optibond FL e Single Bond 2), e de dois cimentos (Variolink II e RelyX ARC), um fotopolimerizável e outro de cura dupla associados às duas técnicas de cimentação formaram-se oito condições de cimentação. As amostras foram submetidas a ensaio de cisalhamento pela técnica do fio de aço. Com base nos valores encontrados nas condições estabelecidas, após o respectivo tratamento estatístico, foi possível concluir que: a) a técnica de cimentação com fotopolimerização simultânea do adesivo com o cimento produziu índices de resistência superiores aos obtidos pela técnica de fotopolimerização prévia do adesivo; b) A combinação do adesivo Single Bond 2 com o cimento Variolink II resultou em menores valores de resistência adesiva, diante das outra três combinações de cimentos e adesivos formadas. / The aim of this study was to evaluate the strength of adhesive bonding of a glass-ceramic (IPS e.max Press) fixed on the enamel of bovine teeth. There were used two methods of cementation one in which the adhesive was pre-cured, and another in which the photopolymerization of the adhesive and composite cement was performed simultaneously after the fixing of ceramic disc, which was 5mm in diameter and 2mm thick. Through a combination of two light cured adhesive systems (Single Bond and FL Optibond 2) and two resin cements (Variolink II and RelyX ARC), one light-cured and another dual-cured associated with the two luting techniques eight conditions of cementation were formed. The samples were subjected to shear test technique. Under the established conditions, after statistical treatment of results the following conclusions could be drawn: a) the cementation technique with simultaneous curing of the adhesive with cement produced resistance rates higher than those obtained by the technique of pre-curing the adhesive; b) the combination of adhesive Single Bond 2 with cement Variolink II resulted in lower bond strength, in comparison with the other three combinations of cements and adhesives formed.
159

Efeito da utilização prévia de agentes dessensibilizantes na resistência de união de sistemas adesivos à dentina humana / Efect of desensitizing agents on the bond strength of adhesive systems to human dentin

Chermont, Armando Brito 30 April 2013 (has links)
O objetivo deste estudo foi avaliar o efeito de agentes dessensibilizantes na resistência de união de diferentes sistemas adesivos condicione e lave e autocondicionantes a dentina humana por meio do microcisalhamento. Foram utilizados sessenta fragmentos de dentina obtidos das superfícies vestibular e lingual de terceiros molares inclusos, que foram distribuídos em grupos (n-12) de acordo com o tratamento dessensibilizante (controle - sem tratamento; oxalato de potássio; CPP-ACP + flúor; arginina; nanohidroxiapatita) e os sistemas adesivos (Adpter Single Bond 2 / 3M; Clearfil SE Bond / Curaray) empregados. As aplicações de agentes dessensibilizantes (2 ml) foram realizadas em três sessões com intervalo de 48 horas. Os fragmentos de dentina permaneceram imersos em 6 ml de saliva artificial no período entre as aplicações. Os sistemas adesivos foram aplicados conforme as orientações dos fabricantes e fotopolimerizados por 40 segundos. Sobre cada superfície dentinária foram confeccionados dois cilindros em resina composta. O ensaio mecânico de microcisalhamento foi realizado usando uma velocidade de 1 mm/min.Os padrões de fratura foram determinados por meio de um microscópio digital com aumento de 50 vezes . As fraturas foram classificadas como adesivas, coesivas em dentina, coesivas em resina e mistas descritas percentualmente pelos testes ANOVA 2-way e o teste Bonferroni (p<0.05) . Concluiu-se que os tratamentos dessensibilizantes influenciaram na resistência de união dos sistemas adesivos condicione e lave; o tratamento com oxalato de potássio e arginina reduziu a resistência de união dos autocondicionantes; o tratamento com CPP-ACP e com a nanohidroxiapatita não interferiram na adesão dos autocondicionantes. / The aim of this study was to evaluate the effect of desensitizing agents on the bond strength of different adhesive systems condition and rinse and self-etching to dentin through microshear. Were used sixty dentin fragments obtained from the buccal and lingual surfaces of molars third molars, which were distributed in groups (n = 12) according to desensitizing treatment (control - no treatment; potassium oxalate; + CPP-ACP fluorine; arginine; nanohidroxiapatita) and adhesive system (Single Bond Adpter 2 / 3M; Clearfil SE Bond / Curaray) employee. The application of desensitizing agents (2 ml) were performed in three sessions with an interval of 48 hours. The dentin fragments remained immersed in 6 ml of artificial saliva in the period between applications. The adhesive systems were applied according to the instructions of the manufacturer and cured for 40 seconds. About every two dentin surfaces were fabricated in composite cylinders. The mechanical test was performed using a microshear speed of 1 mm / min .The fracture patterns were determined using a digital microscope with increased 50 times. Fractures were classified as adhesive, cohesive in dentin and composite resin cohesive described percentage. 2-way ANOVA and the Bonferroni test (p <0.05) It was concluded that the desensitizing treatments influenced the bond strength of adhesive systems and conditional wash; treatment with potassium oxalate and arginine reduced the bond strength of self-etching; treatment with CPP-ACP did not interfere with hydroxyapatite and adhesion of self-etching .
160

Avaliação da resistência à flexão de mini-implantes desenvolvidos para ancoragem esquelética do aparelho de Herbst - Estudo em Minipig br1 / Flexure resistance evaluation of mini implants prototypes developed for Herbst appliance anchorage Study in Minipig br1

Batista, Klaus Barretto dos Santos Lopes 23 April 2010 (has links)
Um efeito colateral indesejável do uso do aparelho de Herbst é a vestibularização excessiva dos incisivos inferiores que pode estar relacionada à retração gengival, à perda óssea marginal e à reabsorção radicular. A ancoragem esquelética do aparelho de Herbst poderia evitar estes problemas. O objetivo do presente estudo foi o de avaliar, em Minipigs br1, a resistência à flexão de protótipos de mini-implantes desenvolvidos para ancoragem do aparelho de Herbst, comparar a resistência dos protótipos entre as duas regiões escolhidas para inserção e avaliar se os protótipos de mini-implantes seriam capazes de suportar forças ortopédicas. Após o cálculo do tamanho da amostra, 13 protótipos de mini-implantes foram colocados nas regiões posterior da maxila e anterior da mandíbula de três Minipigs br1, após terem sido mortos. Corpos de prova contendo os protótipos de mini-implantes inseridos em osso foram submetidos a uma força de flexão por engastamento simples utilizandose uma máquina universal de ensaios mecânicos Instron, calculando-se a média e o desvio padrão para cada região. Com o objetivo de comparar a resistência dos protótipos entre as regiões de inserção foi utilizado o Teste t de Student para duas amostras não pareadas. O teste de hipótese foi realizado para cada região para avaliar se os protótipos de mini-implantes seriam capazes de suportar forças ortopédicas. Para fins de comparação foram consideradas forças ortopédicas acima de 1,0 kgf. O nível de significância adotado foi P < 0,05. Os protótipos de miniimplantes apresentaram resistência à força de flexão de 13,86 kgf (DP = 2,3) para a região posterior da maxila e 20,55 kgf (DP = 5,2) para a região anterior da mandíbula. Houve diferença estatisticamente significativa entre as duas regiões com relação à força de resistência dos mini-implantes (P = 0,015), sendo que a resistência maior foi na região anterior da mandíbula. A hipótese de que os protótipos de mini-implantes seriam capazes de suportar forças ortopédicas foi confirmada para as regiões posterior da maxila e anterior da mandíbula. Os autores concluíram que, em Minipigs br1, os protótipos de mini-implantes desenvolvidos para a ancoragem do aparelho de Herbst foram capazes de resistir a forças entre 13,86 e 20,55 kgf, sendo estatisticamente mais resistentes na região anterior da mandíbula e capazes de suportar forças ortopédicas. / An undesirable tooth movement resulting from use of the Herbst appliance is the excessive proclination of the anterior mandibular teeth, which is commonly associated with gingival recession, marginal bone loss, and root resorption. Skeletal anchorage of the Herbst appliance could prevent these problems. The present study was designed to evaluate, in Minipigs br1, the flexure resistance of prototype miniimplants developed for Herbst appliance anchorage, to compare the prototype resistance between the regions in which the mini-implants were placed, and to test the hypothesis that these mini-implant prototypes can withstand orthopedic forces. After calculation of sample size, 13 mini-implant prototypes (2 mm in diameter x 10 mm long) were inserted in the posterior region of the maxilla and the anterior region of the mandible, in three recently killed minipigs. The specimens were submitted to a single cantilever flexure test using an Instron testing machine. Mean and standard deviation were calculated for each region. To compare the resistance of the prototypes between the sites of mini-implant insertion, a 2-Sample Students t test was calculated. The test was carried out individually for each region, to evaluate if the prototype mini-implants developed for Herbst appliance anchorage could withstand orthopedic forces. Orthopedic forces above 1.0 kgf were considered. The level of significance was set at P < 0.05. The prototype mini-implant showed a flexure strength of 13.86 kgf (SD = 2.3) for the posterior region of the maxilla, and 20.55 kgf (SD = 5.2) for the anterior region of the mandible. A significant statistically difference was found in the resistance of the prototypes between the two regions (P = 0.015). The hypothesis that the prototype mini-implants can withstand orthopedic forces was confirmed. The authors concluded that, in Minipigs br1, the prototype mini-implants developed for Herbst appliance anchorage could resist forces from 13.86 to 20.55 kgf, were statistically more resistant in the anterior region of the mandible, and were capable of withstanding orthopedic forces.

Page generated in 0.0763 seconds