• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 437
  • 135
  • 21
  • 18
  • 10
  • 9
  • 9
  • 9
  • 9
  • 8
  • 6
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 640
  • 365
  • 209
  • 194
  • 184
  • 163
  • 113
  • 104
  • 98
  • 96
  • 87
  • 85
  • 83
  • 77
  • 74
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
211

Estudo cinesiográfico do espaço de pronúncia do som /s/ em indivíduos dentados e desdentados /

Souza, Raphael Freitas de. January 2003 (has links)
Orientador: Marco Antonio Compagnoni / Banca: Francisco de Assis Mollo Junior / Banca: Cláudio Rodrigues Leles / Resumo: Os sons sibilantes, como o /s/, vêm sido usados para avaliar a determinação da dimensão vertical e posicionamento de dentes artificiais. Apesar desse som poder ser destorcido por próteses totais, algum grau de adaptação é esperado. O propósito deste estudo foi avaliar o espaço de pronúncia do /s/ (EPS) em indivíduos dentados e edentados e relacioná-lo aos trespasses incisais e espaço funcional livre (EFL). Dois grupos foram recrutados: I- composto por 25 indivíduos do gênero masculino e 36 do gênero feminino (n = 61) com média etária de 30,26 l 12,71 anos; e II- 10 indivíduos do gênero masculino e 23 do gênero feminino (n = 33) com média etária de 59,18 l 10,00 anos. A análise foi realizada empregando o instrumento cinesiográfico K6 I Diagnostic System (Myotronics Research, Inc., Seattle, WA, EUA) que fornece registros tridimensionais dos movimentos mandibulares. Os indivíduos foram avaliados pela pronúncia da palavra "seis" e as posições mandibulares para o som /s/ em relação à máxima intercuspidação foram registradas. Os trespasses vertical e horizontal, bem como o EFL, também foram mensurados. Os resultados indicaram movimento mandibular protrusivo durante a produção do som /s/ para quase todos os indivíduos do grupo I, mas no grupo II houve uma predominância de retrusão. Idade e gênero não influenciaram o EPS para os dois grupos. Foi encontrada correlação significativa entre o EPS do /s/ e ambos os trespasses para o grupo I, mas não para o grupo II. Houve uma fraca correlação entre os EFL e EPS para o grupo I, mas uma correlação relativamente forte para o grupo II. Esses dados sugerem que o tratamento com próteses totais influenciou a movimentação mandibular durante a produção do /s/. Dessa forma, pode se deduzir que mudanças anatômicas seguindo o procedimento protético produziu uma adaptação funcional nítida que foi ...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The sibilant sounds, such as /s/, have been used as evaluation in determining vertical dimension and placement of artificial teeth. Although it can be distorted by complete dentures, some degree of adaptation can be expected. The aim of this study was to evaluate the /s/ speaking space (SSP) in dentate and edentate subjects, and relate it to the incisal overlaps and freeway space (FS). Two groups were recruited, as follows: I- composed by 25 male and 36 female dentate subjects (n = 61), with mean age of 30,26 l 12,71 years; and II- 10 male and 23 female dentate subjects (n = 33), with mean age of 59,18 l 10,00 years. The kinesiographic equipment K6 I Diagnostic System (Myotronics Research, Inc., Seattle, WA, USA) was used for the assessment, providing three-dimensional records of mandibular movements. Each subject was tested by pronouncing the word 'seis' and the mandibular positions for /s/ sound, in relation to maximal intercuspal position, were recorded. The vertical and horizontal overlaps, and also the freeway space, were also measured. The results showed protusive mandibular movement /s/ production for almost all subjects in group I, but in group II there was a predominance of retrusion. Age and gender didn't influence the measured speaking space for the two groups. Significant correlation was found between SSP and both overlaps for group I, but not for group II. There was a slight correlation between FS and SSP for group I, but a relatively strong correlation for group II. It was suggested that the complete denture treatment influenced the mandibular motion during /s/ production. Also, it can be deduced that anatomic changes following the prosthetic procedure strongly produced functional adaptation that was common for both rest and /s/ speaking positions of the mandible. / Mestre
212

Efeito de diferentes métodos de higienização na remoção de um adesivo para prótese e na redução da microbiota bucal de usuários de prótese total: estudo in vivo /

Nunes, Élen Massaro. January 2015 (has links)
Orientador: Ana Carolina Pero / Co-orientador: / Banca: Marco Antonio Compagnoni / Banca: Claudia Helena Lovato da Silva / Resumo: Esse estudo avaliou in vivo (n=20) a eficácia de diferentes métodos de higienização na remoção de um adesivo para prótese total (Ultra Corega creme) e na redução da carga microbiana oral. Os métodos de higienização foram escovação das próteses com escova de cerdas macias utilizando: A (água em temperatura ambiente), B (água em temperatura ambiente + sabão de coco), C (água em temperatura ambiente + dentifrício) e D (água + imersão em solução de perborato de sódio por 5 minutos). Foi realizada coleta de saliva antes e após a utilização do adesivo e realização dos métodos de higienização. As superfícies internas das próteses totais superiores foram coradas com índigo carmim 0,4% e as áreas cobertas por adesivo foram quantificadas (%) por meio de um método fotográfico e auxílio de um software (Image Tool). Para a análise microbiológica, a saliva coletada foi diluída e plaqueada em um meio de cultura não-seletivo (Mueller Hintön Agar) e em meios de cultura para Candida spp (Sabouraud Dextrose Agar e CHROMagar Candida). Após o período de incubação (48 horas/37ºC), as espécies de Candida foram identificadas e o número de unidades formadoras de colônias (UFC/mL) foram calculados. Conclui-se que a escovação combinada com a imersão das próteses em perborato de sódio foi mais eficaz na remoção do adesivo quando comparado com a escovação com água (Dunn, p=0,004). Para os meios de cultura não seletivo (ANOVA,p>0,05) e seletivos para Candida spp (Friedman, p>0,05), não foi observada influência dos métodos de higienização na carga microbiana oral. / Abstract: This study evaluated in vivo (n=20) the effectiveness of different cleaning methods in removing an adhesive for dentures (Ultra Corega cream) and the reduction of microorganisms in the oral microbiota. The cleaning methods were brushing the dentures with soft bristle brush using: A (room temperature water), B (water at room temperature + coconut soap), C (room temperature + dentifrice in water) and D (water+immersion in sodium perborate solution for 5 minutes). Saliva samples were taken before and after using the adhesive and realization of cleaning methods. The inner surfaces of the upper dentures were stained with 0.4% indigo carmine and the adhesive-covered areas were quantified (%) by means of a photographic method and assistance for a software (Image Tool). For microbiological analyzes the collected saliva was diluted and plated in a medium non-selective medium (Mueller Hinton Agar) and culture media for Candida spp (Sabouraud Dextrose Agar and CHROMagar Candida). After the incubation period (48 hours / 37°C), Candida species were identified and the number of colony forming units (CFU / ml) were calculated. It was concluded that the brushing combined with the immersion of the prosthesis into sodium perborate was more effective in removing the adhesive as compared with brushing with water (Dunn, p=.004). For the non selective media (ANOVA,p>0,05) and selective for Candida spp (Friedman, p>0,05), there was no influence of the cleaning methods on the oral microbiota. / Mestre
213

Influência do método de aquecimento de revestimentos fosfatados sobre sua resistência à compressão e sobre a rugosidade de superfície e estabilidade dimensional de ligas de Ni-Cr e Ni-Cr-Ti /

Zequetto, Michele Marques. January 2009 (has links)
Orientador: Eulália Maria Martins Silva / Banca: Maria Cristina Rosifini Alves Rezende / Banca: Paulo Renato Junqueira Zuim / Banca: Renata Garcia Fonseca / Banca: Maria da Gloria Chiarello de Mattos / Resumo: No processo de fundição pela cera perdida, os materiais envolvidos podem apresentar interações entre si e o de tempo despendido para se obter as estruturas metálicas é oneroso. Assim, o objetivo deste trabalho foi avaliar a influência da propriedade física de resistência à compressão de revestimentos fosfatados indicados para altas temperaturas de fundição, utilizando os métodos de aquecimento convencional (MAC) e rápido (MAR), e analisar a rugosidade de superfície e a alteração dimensional do produto final da fundição (a peça metálica) obtido com as ligas metálicas Ni-Cr (Verabond II) e Ni-Cr-Ti (Fit Cast Titanium). Os revestimentos estudados Castorit Super C, Castorit All Speed, Heat Shock e Micro Fine 1700 foram vazados em uma matriz de silicone que permitiu obter amostras com formato cilíndrico (n=200), medindo 10mm de diâmetro e 20mm de comprimento. A resistência (MPa) deles foi determinada à temperatura ambiente (resistência fria) após 15, 30 e 60 minutos de manipulação, e também imediatamente após serem submetidos aos métodos de aquecimento MAC e MAR (resistência de queima), por meio de uma máquina de ensaio universal, em velocidade de 0,05mm/min e carga de 150kgf. Após inclusão, aplicação dos métodos de aquecimento e fundição às amostras (n=120) para rugosidade de superfície (Ra-μm), foram avaliadas por um rugosímetro Mitutoyo Surftest SJ-401 com cut-off de 0,8mm e três repetições em cada amostra. A alteração dimensional foi determinada pela diferença entre os valores dimensionais da cera e da peça fundida (n=60) utilizando-se o software AutoCad2008. Os valores médios obtidos foram submetidos à análise de variância (ANOVA) e ao teste de Tukey (p<0,05), apresentando os valores de resistência à compressão diferentes entre os revestimentos (Heat Shock os valores maiores) e entre os tempos de mensuração em relação... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In the lost wax casting procedure, the involved materials can present interactions among them and the time used to obtain the metallic structures is onerous. Thus, the purpose of this study was to evaluate the influence of the compressive strength physical property of phosphate-bonded investment materials indicated for high casting temperatures, utilizing conventional heating (CHM) and quick heating methods (QHM), and analyze the surface roughness and the dimensional accuracy of the final casting product (the metallic piece) obtained from Ni-Cr (Verabond II) and Ni-Cr-Ti (Fit Cast Titanium) metallic alloys. Castorit Super C, Castorit All Speed, Heat Shock and Micro Fine 1700 investment materials were poured into a silicone matrix in order to obtain cylindrical samples (n=200), measuring 10mm in diameter and 20mm in length. Their strength (MPa) was determined at room temperature (green strength) after 15, 30 and 60 minutes of manipulation, and also immediately after being submitted to the CHM and QHM heating methods (fired strength), by means of an universal testing machine at 0,05mm/min speed and 150kgf load. After investing, applying the heating methods and casting the samples (n=120) for surface roughness (Ra), the samples were evaluated with a Mitutoyo Surftest SJ-400 profilometer with 0,8mm cut-off, three times in each sample. The dimensional accuracy was determined by the difference among the dimensional values of the wax and of the metallic piece (n=60) through the software AutoCad2008. The mean values obtained were submitted to ANOVA and Tukey tests (p <0.05), and the results showed that the values of compressive strength were different among the investment materials (Heat Shock presenting the highest values) and among the analysis times with a direct relation of time and strength increase, but there was no difference between CHM and QHM. Moreover, it was observed no differences... (Complete abstract click electronic access below) / Doutor
214

Avaliação dos elementos finitos de tensões no tecido ósseo peri-implantar durante a osseointegração / Finite element analysis of stresses in peri-implant bone tissue during osseointegration

Santos, Mateus Bertolini Fernandes dos, 1985- 02 September 2011 (has links)
Orientador: Rafael Leonardo Xediek Consani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-17T13:50:15Z (GMT). No. of bitstreams: 1 Santos_MateusBertoliniFernandesdos_D.pdf: 5044188 bytes, checksum: b81a4d5dccdc37cad705fb6ddaf4b97c (MD5) Previous issue date: 2011 / Resumo: Forças aplicadas por próteses totais a implantes submersos durante o período deosseointegração podem, em alguns casos, levar ao insucesso clínico. Até o momento não existe trabalho na literatura que quantifique e/ou verifique a distribuição das forças mastigatórias em implantes submersos durante a ação mastigatória de próteses totais convencionais usadas provisoriamente durante o período de osseointegração. Dessa forma, neste trabalho foram avaliadas as tensões geradas no tecido ósseo subjacente a implantes recém-colocados, em diferentes situações, durante a ação mastigatória em próteses totais convencionais provisórias inferiores, por meio da metodologia dos elementos finitos. Com software de modelagem 3-D (SolidWorks 2010, SolidWorks Corp., Concord, Massachusetts, EUA) foram confeccionados modelos tridimensionais de mandíbula simulando diferentes situações clínicas: (1) implantes submersos, próteses totais convencionais e próteses reembasadas com diferentes materiais reembasadores macios; (2) diferentes níveis de altura de exposição dos cicatrizadores (submerso, nível gengival, 1,5 mm exposto no meio bucal); e (3) diferentes espessuras e comparação entre reembasamento na base da prótese inteira ou somente na região dos implantes. As análises foram realizadas em software específico (ANSYS Workbench 12, Ansys Inc., Canonsburg, Pennsylvania, EUA) e para cada modelo foram simuladas duas situações, com aplicação de carga mastigatória em canino inferior direito (35N) e primeiro molar inferior direito (50N). Todas as análises foram realizadas em tensão máxima principal, em MPa. Os resultados obtidos demonstraram que o reembasamento da prótese com material macio reduziu a concentração de tensões no tecido ósseo peri-implantar, sendo a concentração de tensão diretamente relacionada com a maciez do material. Os cicatrizadores submersos foram os que apresentaram menor valor de concentração de tensões. A espessura e área de reembasamento estão relacionadas à transmissão de tensões ao osso peri-implantar, quando o reembasamento da região dos implantes com espessura de 3 mm apresentou melhores resultados. Comparando-se os resultados mostrados nas diferentes simulações conclui-se que a situação que promoveu menor concentração de tensões no osso peri-implantar foi com implantes submersos, reembasamento realizado somente na região dos implantes, espessura de 3 mm e material macio. / Abstract: Forces applied to submerged implants from complete dentures during the osseointegration period can, in some cases, lead to clinical failure. To date there is no study in the literaturethat quantifies and/or verifies the stress distribution of occlusal forces in submerged implants during the masticatory function of conventional complete dentures used on an interim basis during the period of osseointegration. Thus, this study evaluated the stresses in the bone adjacent to newly placed implants during the masticatory function in conventional complete dentures through the finite element methodology. Using a 3-D modeling software (SolidWorks 2010, SolidWorks Corp., Concord, Massachussets, EUA) it were made tridimensional models of a mandible simulating different clinical situations: (1) submerged implants, conventional complete dentures and relined ones with different soft liner materials; (2) different height levels of exposure to the oral environment (submerged, gingival level and 1.5mm of exposure to the oral environment); and (3) different thickness and comparation between relining the entire base or only in the region near the implants. The analysis were made in a specific software (ANSYS Workbench 12, Ansys Inc., Canonsburg, Pennsylvania, EUA) and for each model it were simulated two situations with masticatory load in inferior right canine (35N) and inferior right first molar (50N). All the analysis were made in maximum principal stress, in MPa. The obtained results showed that relined dentures with soft liner material reduced the stress concentration in the peri-implant bone tissue, being the stress concentration directly related to the softness of the material. Submerged implants presented the lowest values of stress concentration in the peri-implant bone tissue. The thickness and the area of reline are related to the transmission of stress to the peri-implant bone tissue, when relining the denture only in the region of the implants with a 3-mm thick layer of soft liner material presented better results. Comparing the results obtained from the different simulations it is possible to conclude that the situation which promoted fewer stress concentration in the peri-implant bone was with submerged implants, relining made only in the implants region, thicker layer (3 mm) of reline and softer material. / Doutorado / Protese Dental / Doutor em Clínica Odontológica
215

Análise da fala, do tônus muscular orofacial e das mobilidades dos lábios, da língua e da mandíbula em usuários de prótese total superior / Oral rehabilitation with complete denture: an analysis of speech, tonus and mobility of lips, tongue and jaw

Daniele de Oliveira Brito 04 November 2010 (has links)
Objetivo: Comparar a fala, o tônus e as mobilidades dos lábios, da língua e da mandíbula de usuários de prótese total em diferentes períodos de adaptação. Método: Foram avaliados quanto aos aspectos de fala, tônus e mobilidades dos lábios, da língua e da mandíbula, quarenta usuários de prótese total (grupo experimental) e quarenta sujeitos com dentição natural (grupo controle). O grupo experimental foi dividido em três sub amostras, de acordo com o tempo de uso da prótese, a saber, um mês, seis meses e 12 meses. Resultados: Há maior dificuldade das mobilidades dos lábios, da língua e da mandíbula e maior alteração de tônus muscular orofacial em usuários de próteses há 12 meses, tanto na comparação entre os dois grupos, quanto entre as sub amostras do grupo experimental; piores resultados para a fala automática são observados em usuários de prótese há seis meses, ao contrário da nomeação, coordenação motora da fala e fala espontânea, que são aos 12 meses de uso da prótese. Estes resultados ocorreram novamente, tanto na comparação entre os grupos experimental e controle, quanto na comparação das sub amostras do grupo experimental entre si. Conclusões: Os dados obtidos neste estudo demonstraram que usuários de prótese total há 12 meses apresentam maior dificuldade para as mobilidades dos lábios, da língua e da mandíbula, para o tônus muscular orofacial e para a fala, que aqueles que têm um ou seis meses de tempo de uso. / Objective: To compare speech, tonus and mobility of lips, tongue and jaw denture wearers in different periods of adaptation. Methods: We evaluated the aspects of speech, tonus and mobility of lips, tongue and jaw, forty denture wearers (experimental group) and forty subjects with natural teeth (control group). The experimental group was divided into three sub samples, according to the time of fitting, ie one month, six months and 12 months. Results: There is increased difficulty of mobility of the lips, tongue and jaw and greatest change in muscle tone in orofacial prosthesis users for 12 months in the comparison between the two groups, and between the sub experimental samples; worse results for Automatic speech are seen in hearing aid users for six months, as opposed to the appointment, coordination of speech and spontaneous speech, which are at 12 months of fitting. These results were again, in the comparison between the experimental and control groups and in the comparison of experimental samples under each other. Conclusions: The results of this study showed that denture wearers is the most difficult 12 months for the mobility of the lips, tongue and jaw, for orofacial muscle tone and speech, that those who have one or six months time of use.
216

Detecção da expressão dos genes HWP1, ALS1 e ALS3 de C.albicans, por meio de RT-PCR em tempo real, após desinfecção química e por microonda, de resina acrílica para confecção de dentaduras / HWP1, ALS1 and ALS3 genes expression in Candida albicans after chemical or microwave disinfection of acrylic resin for denture prosthesis using real time PCR

Luciana de Rezende Pinto 24 June 2010 (has links)
A desinfecção de dentaduras promove o controle do biofilme microbiano e previne doenças, como a estomatite por uso de dentadura, associada à presença de Candida albicans. A expressão dos genes HWP1, ALS1, ALS3 deste fungo está relacionada à adesão das células fúngicas às do hospedeiro. O objetivo deste estudo foi detectar e quantificar a expressão desses genes em células planctônicas e biofilme de Candida albicans, desenvolvidos sobre superfícies de resina acrílica, após tratamento com dois métodos de desinfecção. Corpos de prova de resina acrílica, previamente tratados por hipoclorito de sódio 1%, microondas, e um grupo não tratado, foram inoculados com Candida albicans para desenvolvimento de biofilme. O biofilme e as células planctônicas foram coletados em três tempos distintos, correspondentes às etapas de desenvolvimento do biofilme: inicial (6h), intermediária (12h) e madura (48h) e a expressão gênica foi quantificada pelo ensaio de RT-PCR em tempo real. Os dados obtidos foram submetidos ao teste estatístico ANOVA two-way e pós-teste de Bonferroni; valores de p<0,05, p<0,01 e p<0,001 foram considerados significantes. Os três genes avaliados foram detectados e quantificados por RT-PCR em tempo real, em biofilmes e células planctônicas, independente do grupo de tratamento ou tempo de desenvolvimento do biofilme. A expressão dos genes ALS1 e ALS3 variou de acordo com o tempo de desenvolvimento do biofilme e, e com o tratamento da superfície. Ocorreu diferença significativa (p<0,001) entre a expressão desses genes nas superfícies tratadas por hipoclorito de sódio e microondas, além de diferenças significativas (p<0,001) na expressão gênica entre células planctônicas e biofilme, para os tratamentos avaliados. Concluiu-se que os tratamentos de desinfecção alteram o padrão da expressão dos genes ALS1 e ALS3 em biofilmes desenvolvidos sobre superfície de resina acrílica e em células planctônicas e este padrão foi diferente entre os tratamentos de desinfecção. / Complete dentures disinfection promotes biofilm control and prevents diseases such as denture stomatitis associated with the presence of Candida albicans infection. The expression of the genes HWP1, ALS1, ALS3 in this fungus is related to the adhesion of fungal cells to the host tissues. Therefore, the aim of this study was to detect and quantify the expression of these genes in planktonic cells and biofilms of Candida albicans, developed on acrylic resin surfaces, after treatment with two disinfection methods. Specimens of acrylic resin, previously treated by 1% sodium hypochlorite or microwave, and an untreated group were inoculated with Candida albicans for biofilm development. Biofilm and planktonic cells were collected at three different time points corresponding to biofilm development stages: initial (6 h), intermediate (12h) and mature (48h). The total RNA of these samples was obtained and the gene expression for mRNA of HWP1, ALS1 and ALS3 were quantified by Real-Time RT-PCR assay. The data obtained were assessed throught two-way ANOVA and Bonferroni post-test. Significant levels were determined for p values at <0.05. The three genes were detected and quantified in both biofilms and planktonic cells regardless of treatment condition or time of biofilm development. ALS1 and ALS3 expression varied according to the time point, and surface treatment. Significant differences (p <0.001) were showed between gene expression on surfaces treated with sodium hypochlorite and microwave, and significant differences (p <0.001) were showed in gene expression between planktonic and biofilm cells. It can be concluded that the disinfection procedures affect the ALS1 and ALS3 expression patterns in Candida albicans denture biofilms and planktonic cells. Additionaly, differential gene expression patterns were observed among the disinfection treatments.
217

Padronização da metodologia para análise de sorção de água e solubilidade de materiais resilientes temporários para  base de prótese / Standardization of methodology for water sorption and solubility analysis of temporary resilient denture liners

Janaina Gomes Maciel 08 June 2016 (has links)
Não existem normas internacionais que determinem limites aceitáveis de sorção de água e solubilidade para os materiais resilientes temporários para base de prótese, além de haver divergências metodológicas nos estudos. Objetivou-se avaliar de forma padronizada essas propriedades físicas para materiais macios de curta duração ao longo de sua vida útil. Corpos de prova (50mm x 0,5mm/ ISO-10139-2) de 7 condicionadores teciduais (Coe-Comfort-CC, Softone-ST, Rite-Line-RL, Dura Conditioner-DC, Hydro-Cast-HC, DentusoftDS e Visco-gel-VG) e 2 reembasadores resilientes temporários (Trusoft-TS e Coe-Soft-CS) foram individualmente confeccionados e submetidos à dessorção até estabilização das massas. Então, foram imersos em água destilada a 37oC por 3, 5, 7 ou 14 dias (n=10) para depois serem pesados, dessecados e pesados novamente. Os dados foram obtidos em porcentagens de sorção/solubilidade e analisados estatisticamente por ANOVA 2 fatores e teste de Tukey HSD (&#x3B1;=0,05). Em todos os períodos, VG (12,06±0,93 a 16,62±0,87%) apresentou a maior sorção de água dentre os materiais testados, sendo as menores porcentagens observadas para CC (2,23±0,53 a 2,99±0,49%) (P<0,05). CC, CS e TS não apresentaram alteração significativa da sorção de água ao longo de 14 dias (P>0,05). Já os demais materiais exibiram um aumento significativo da sorção de água entre os períodos de 7 e 14 dias (P<0,05). Para a solubilidade, valores médios inferiores e estatisticamente semelhantes foram apresentados pelos materiais DC, HC, DS, TS, RT e CS (0,28±0,30 a 2,13±0,23%) (P>0,05). ST (4,09±1,60 a 8,80±1,15%) demonstrou maior solubilidade que CC (1,89±0,30 a 3,35±0,70%), mas os mais altos valores percentuais dentre os materiais testados foram observados para VG (20,30±4,26 a 23,59±20,24%) (P<0,05). CC, DC, DS, HC, RT, TS e CS não apresentaram alterações na solubilidade percentual média ao longo dos 14 dias de avaliação. Já os condicionadores teciduais VG e ST exibiram aumento dos valores médios apenas aos 14 dias de imersão em água. Conclui-se que, ao longo da vida útil média de um condicionador tecidual (7 dias), os materiais CC, DC, HC, DS, RL, CS e TS apresentaram comportamento in vitro satisfatório em relação à sorção de água e solubilidade. De acordo com os resultados obtidos, os materiais CC, TS e CS foram considerados os mais indicados dentre os testados para reembasamento de próteses em até 14 dias. / There are no international standards that determine acceptable limits of water sorption and solubility for the temporary resilient liners, besides the differences in the methodology of the studies. It was aimed to evaluate in a standardized manner these physical properties of short-term soft materials throughout their lifespan. Specimens (50mm x 0.5mm/ ISO-10139-2) of 7 tissue conditioners (Coe-Comfort-CC, Softone- ST, Rite-Line-RL, Dura Conditioner-DC, Hydrocast-HC, Dentusoft-DS and Visco-gel- VG) and 2 temporary resilient liner (Trusoft-TS e Coe-Soft-CS) were individually prepared and submitted to desorption until mass stabilization. Afterwards, they were immersed in distilled water at 37oC for 3, 5, 7, or 14 days (n=10) to then be weighed, dried and reweighed. The data were obtained in percentages of sorption/solubility and statistically analyzed by 2-way ANOVA and Tukeys test (&#x3B1;=0.05). In all periods, VG (12.06±0.93 to 16.62±0.87%) showed the highest water sorption among the tested materials, with the lowest percentages observed for CC (2.23±0.53 to 2.99±0.49%) (P<0.05). CC, CS and TS showed no significant changes in water sorption over 14 days (P>0.05). The other materials exhibited a significant increase in water sorption between the periods of 7 and 14 days (P<0.05). For the solubility, lower (and statistically similar to each other) values were presented by DC, HC, DS, TS, RT, and CS materials (0.28±0.30 to 2.13±0.23%) (P>0.05). ST (4.09±1.60 to 8.80±1.15%) showed higher solubility than CC (1.89±0.30 to 3.35± 0,70%), but the highest percentages among tested materials were observed for VG (20.30±4.26 to 23.59±20.24%) (P<0.05). CC, DC, DS, HC, RT, TS, and CS showed no changes in the mean percentage solubility throughout the 14-day trial. The tissue conditioners VG and ST exhibited increased average values only at 14 days of water immersion. It was concluded that, over the lifespan of a tissue conditioner (7 days), the materials CC, DC, HC, DS, RL, CS, and TS presented suitable in vitro performance with respect to water sorption and solubility. According to the results, the materials CC, TS, and CS were considered best suited among the tested materials for denture relining of up to 14 days.
218

Estudo in vitro da deformação permanente em grampos a barra fundidos em ligas de cobalto-cromo e em titânio comercialmente puro, submetidos a testes de tensão-deformação. / Permanent deformation in vitro study of “I” bar clasps cast with cobalt-chromium alloy and commercially pure Titanium, submitted to tension-deformation trials.

Mauricio José Arrais 14 April 2005 (has links)
Foram realizados testes de inserção e remoção de grampos a barra em “I”, fundidos com liga de Cobalto-Cromo (CoCr) e com Titânio comercialmente puro (Ti). Foi utilizada uma máquina oscilante de teste para verificar o comportamento elástico destes grampos que atuaram sobre superfícies metálicas com graus de retenção de 0,25mm e 0,50mm. Dez grampos de CoCr e dez de Ti foram submetidos a 12.500 ciclos de teste (cada) sobre as superfícies metálicas. A ocorrência da deformação permanente dos grampos foi mensurada por meio de relógios comparadores colocados sobre as pontas dos retentores, sendo que a leitura destes relógios ocorreu a cada 500 ciclos. Os resultados desta pesquisa in vitro indicaram que, após os 12.500 ciclos, não foram observadas fraturas nos grampos. E ainda que os grampos feitos em liga de CoCr sofreram menores deformações permanentes do que os de Ti para ambas as retenções. / Insertion and removal trials of “I” bar clasps cast with cobalt-chromium alloy and commercially pure Titanium were carried out. An oscillating trial machine was utilized to verify the elastic behavior of these clasps, which acted on metallic surfaces with 0.25mm and 0.50mm degrees of retention. Ten CoCr clasps and ten Ti clasps were submitted to 12,500 trial cycles (each) on the metallic surfaces. The permanent deformation of the clasps was measured b y comparative gauges placed on the tips of the clasps, and the reading of the gauges was carried out every 500 cycles. The results of this in vitro research showed that after the 12,500 cycles clasp fractures were not observed and that clasps made with CoCr alloy suffered less permanent deformation than Ti ones for both degrees of retention.
219

Queijo minas frescal suplementado com probiótico para o controle de Candida sp. isolados da cavidade bucal de usuários de próteses totais - estudo duplo-cego randomizado / Minas frescal cheese supplemented with probiotics for control of Candida sp. isolated from oral cavity of complete denture wearers - double-blind randomized trial

Tatiana Yuriko Miyazima 11 March 2014 (has links)
Os probióticos são organismos vivos que quando ingeridos em quantidades adequadas, conferem benefícios aos indivíduos. Um destes benefícios é a capacidade de inibir o crescimento de micro-organismos patogênicos como Candida. Para avaliar a redução ou inibição de Candida em usuários de próteses totais promovida pela ingestão de probióticos, foram recrutados 135 pacientes, dos quais 59 permaneceram até o final do período experimental de 8 semanas. A ingestão dos probióticos ocorreu através de sua incorporação em queijo minas frescal. Foram selecionados pacientes usuários de próteses totais, uni ou bimaxilares albergando Candida na cavidade bucal. As amostras foram coletadas através de um enxaguado bucal 1 semana antes do início do experimento e ao final do período experimental de 8 semanas. Foi determinado o número de UFC de Candida/ml da amostra. Os sujeitos da pesquisa (n=59) receberam embalagens com 20g de queijo minas frescal a cada 14 dias por 8 semanas consecutivas. Os participantes foram divididos aleatoriamente em três grupos, experimental 1 e 2, e controle. Os grupos experimentais receberam os queijos suplementados com probióticos, respectivamente, Lactobacillus acidophilus NCFM e Lactobacillus rhamnosus Lr-32, e o grupo controle recebeu o queijo sem suplementação probiótica. Os queijos possuíam semelhança quanto a aroma e cor. Além da quantificação de Candida, foram realizados testes para identificação das espécies e avaliação da atividade enzimática da fosfolipase e proteinase. Os resultados inferem que os probióticos L. acidophilus NCFM e L. rhamnosus Lr-32 suplementados em queijo minas frescal foram capazes de reduzir os níveis de Candida bucal, em pacientes usuários de próteses totais, após ingestão diária dos queijos por 8 semanas consecutivas. Antes e após 8 semanas do experimento, Candida albicans foi a espécie mais isolada dos pacientes nos três grupos avaliados. Não houve diferença significativa com relação à atividade enzimática da fosfolipase e proteinase, pelos isolados de Candida sp., antes e após 8 semanas de ingestão do queijo. Conclusão: os dados indicam que queijos contendo L. acidophilus NCFM ou L. rhamnosus Lr-32 tem o potencial de reduzir a colonização oral por Candida, sugerindo a sua utilização para reduzir o risco de candidoses da cavidade oral. / Probiotics are living organisms which when ingested in adequate amounts confer benefits to individuals. One of these benefits is the ability to inhibit the growth of pathogenic microorganisms such as Candida. Reduction or inhibition of Candida isolated from complete denture wearers, uni or bimaxillary, was evaluated by ingestion of minas frescal cheese supplemented with probiotics. 135 patients were recruited, who 59 remained until the end of the experiment. The participants were patients in treatment at the Faculdade de Odontologia da Universidade de São Paulo. The samples were collected through a rinsed mouthwash at the base line and 8 weeks of experiment, before the installation of the new prosthesis. The samples were inoculated on Saubouraud agar dextrose with chloramphenicol plates, incubated for 24-48 hours, in order to quantify in colony-forming units per milliliter (CFU/mL) of Candida presents in the oral cavity of these patients. Subjects who presented fungus positive culture received packages containing 20g of minas frescal cheese every 14 days for 8 consecutive weeks. The participants were divided into three groups: two experimental and one control. The experimental groups received the cheeses supplemented with probiotics Lactobacillus acidophilus NCFM and Lactobacillus rhamnosus Lr-32. The control group received the cheese without probiotic supplementation. The cheeses had similarity as flavoring and coloring. In addition to the quantification of Candida, tests for species identification, phospholipase and proteinase activities were carried out. The results infer that L. acidophilus NCFM and L. rhamnosus Lr-32 supplemented in minas frescal cheese were able to reduce the levels of oral Candida in complete denture wearers, after daily intake of cheeses for 8 weeks of the experiment. At baseline and after 8 weeks of the experiment Candida albicans was the most frequently isolated from denture wearers in all groups. Furthermore, no significant difference was observed in the phospholipase and proteinase activities by isolates of Candida sp., before and after 8 weeks of ingestion of cheese. Conclusion: The data indicate that L. acidophilus NCFM and L. rhamnosus Lr-32 has the potencial to reduce Candida colonization in oral cavity, suggesting its use for reducing the risk of oral candidiasis.
220

"Estudo da produção de prótese removível em laboratórios da cidade de São Paulo" / Study of Removable Denture Production in laboratories of São Paulo city

Claudia Ferreira Neves 15 September 2005 (has links)
O propósito deste trabalho foi analisar a produção de prótese removível em três laboratórios da cidade de São Paulo observando o perfil da população que recebeu este tratamento. A produção foi registrada diariamente, por meio de ensaios fotográficos padronizados, durante um mês de trabalho junto aos laboratórios. Foram enviados questionários para complementação de informações das técnicas e materiais utilizados pelos técnicos responsáveis. Da amostra de 367 próteses, 52% foram feitas para mulheres, e 33% para homens; não se notou diferenças estatisticamente significantes entre a quantidade de modelos nos arcos maxilares e mandibulares; segundo a classificação de Kennedy, a Classe I foi a mais freqüente principalmente para os arcos inferiores e, para os arcos superiores, a Classe III; o conector mais utilizado para o arco inferior foi a barra lingual e para o arco superior o tipo em forma de ferradura; com relação aos dentes remanescentes a média de dentes retidos para os arcos inferiores foi de 7,72 dentes, e para os arcos superiores foi de 7,54 dentes; a grande maioria de prótese confeccionada foi a de armação de cobalto-cromo, com grampo circuferencial, ou a barra; as próteses terapêuticas apresentaram uma porcentagem de 5,45% do total. / The aim of this work was to analyze the removable denture production in three dental laboratories, city of São Paulo, regarding to the population profile submitted to this treatment. The production was daily registered, through pattern photographs, during one month of work in each laboratory. Questionnaires were sent in order to obtain a complementation in technical and material information used by the responsible technicians. From the 367 dentures of the sample, 52 % were obtained from women and 33% from men; it was not observed significant statistical differences between the quantity of maxillary and mandibular models; according to Kennedy classification, the Class I was most frequent in inferior dental arches while the Class III was most frequent in superior dental arches; the most used connector was the lingual bar in inferior dental arches and the horseshoe type in superior dental arches; regarding the teeth remaining the mean values were 7.72 teeth for inferior dental arches and 7.54 for superior dental arches; the great majority of prosthesis was confectioned in chrome-cobalt with circumferential arm clasp or bar clasp; the therapeutic prosthesis presented a percentage of 5.45% from the total.

Page generated in 0.0689 seconds