• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 1
  • 1
  • 1
  • Tagged with
  • 6
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

歩行者の交差点における信号無視行動とその態度との関連について: 公的・私的自己意識も踏まえて

北折, 充隆, Kitaori, Mitsutaka 27 December 1999 (has links)
国立情報学研究所で電子化したコンテンツを使用している。
2

Microscopic Characteristics of Partially Saturated Soil and their Link to Macroscopic Responses / 不飽和土の微視的特性とそれらの巨視的応答へのリンク

Kido, Ryunosuke 25 March 2019 (has links)
京都大学 / 0048 / 新制・課程博士 / 博士(工学) / 甲第21737号 / 工博第4554号 / 新制||工||1710(附属図書館) / 京都大学大学院工学研究科社会基盤工学専攻 / (主査)教授 木村 亮, 准教授 肥後 陽介, 准教授 木元 小百合 / 学位規則第4条第1項該当 / Doctor of Philosophy (Engineering) / Kyoto University / DFAM
3

Monotonic and Fatigue Performance of RC Beams Strengthened with Externally Post-Tensioned CFRP Tendons

El Refai, Ahmed January 2007 (has links)
External post-tensioning is an attractive technique for strengthening reinforced concrete structures because of its ability to actively control stresses and deflections, speed of installation, minimum interruption for the existing structure, and ease of inspection under service conditions. However, external prestressing implies exposing the tendons to the environment outside the concrete section, which may lead to corrosion in steel tendons. Therefore, the interest in using fiber reinforced polymer (FRP) tendons, which are corrosion resistant, has increased. The present work investigated, experimentally and analytically, the flexural performance of reinforced concrete beams strengthened with externally post-tensioned Carbon FRP (CFRP) tendons, under monotonic and fatigue loadings. Initially, tensile fatigue tests were carried out on CFRP tendon-anchor assemblies to assess their response under repeated cyclic loads, before implementing them in the beam tests. New wedge-type anchors (Waterloo anchors) were used in gripping the CFRP specimens. The assemblies exhibited excellent fatigue performance with no premature failure occurring at the anchorage zone. The fatigue tests suggested a fatigue limit of a stress range of 10% of the tendon ultimate capacity (approximately 216 MPa). Monotonic and fatigue experiments on twenty-eight beams (152x254x3500 mm) were then undertaken. Test parameters included the tendon profile (straight and double draped), the initial loading condition of the beam prior to post-tensioning (in-service and overloading), the partial prestressing ratio (0.36 and 0.46), and the load ranges applied to the beam during the fatigue life (39% to 76% of the yield load). The CFRP tendons were post-tensioned at 40% of their ultimate capacity. The monotonic tests of the post-tensioned beams suggested that overloading the beam prior to post-tensioning increased the beam deflections and the strains developed in the steel reinforcing bars at any stage of loading. However, overloading had no significant effect on the yield load of the strengthened beam and the mode of failure at ultimate. It also had no discernable effect on the increase in the tendon stress at yielding. The maximum increase in the CFRP stress at yield load was approximately 20% of the initial post-tensioning stress, for the in-service and overloaded beams. A very good performance of the strengthened beams was observed under fatigue loading. The fatigue life of the beams was mainly governed by the fatigue fracture of the internal steel reinforcing bars at a flexural crack location. Fracture of the bars occurred at the root of a rib where high stress concentration was likely to occur. No evidence of wear or stress concentration were observed at the deviated points of the CFRP tendons due to fatigue. The enhancement in the fatigue life of the strengthened beams was noticeable at all load ranges applied. Post-tensioning considerably decreased the stresses in the steel reinforcing bars and, consequently, increased the fatigue life of the beams. The increase in the fatigue life was slightly affected by the loading history of the beams. At the same load range applied to the beam, increasing the amount of the steel reinforcing bars for the same post-tensioning level decreased the stress range in the bars and significantly increased the fatigue life of the strengthened beams. In the analytical study, a monotonic model that predicts the non-linear flexural response of the CFRP post-tensioned beams was developed and implemented into a computer program. The model takes into account the loading history of the strengthened beams prior to post-tensioning (in-service and overloading). Good agreement was obtained between the measured and the predicted monotonic results. A strain-life based fatigue model was proposed to predict the fatigue life of the CFRP post-tensioned beams. The model takes into consideration the stress-strain history at the stress raisers in the steel bars. It accounts for the inelastic deformation occurring at the ribs during cycling and the resulting changes in the local mean stresses induced. Good agreement between the experimental and predicted fatigue results was observed. A step-by-step fatigue design approach is proposed for the CFRP externally post-tensioned beams. General conclusions of the study and recommendations of future work are given.
4

Monotonic and Fatigue Performance of RC Beams Strengthened with Externally Post-Tensioned CFRP Tendons

El Refai, Ahmed January 2007 (has links)
External post-tensioning is an attractive technique for strengthening reinforced concrete structures because of its ability to actively control stresses and deflections, speed of installation, minimum interruption for the existing structure, and ease of inspection under service conditions. However, external prestressing implies exposing the tendons to the environment outside the concrete section, which may lead to corrosion in steel tendons. Therefore, the interest in using fiber reinforced polymer (FRP) tendons, which are corrosion resistant, has increased. The present work investigated, experimentally and analytically, the flexural performance of reinforced concrete beams strengthened with externally post-tensioned Carbon FRP (CFRP) tendons, under monotonic and fatigue loadings. Initially, tensile fatigue tests were carried out on CFRP tendon-anchor assemblies to assess their response under repeated cyclic loads, before implementing them in the beam tests. New wedge-type anchors (Waterloo anchors) were used in gripping the CFRP specimens. The assemblies exhibited excellent fatigue performance with no premature failure occurring at the anchorage zone. The fatigue tests suggested a fatigue limit of a stress range of 10% of the tendon ultimate capacity (approximately 216 MPa). Monotonic and fatigue experiments on twenty-eight beams (152x254x3500 mm) were then undertaken. Test parameters included the tendon profile (straight and double draped), the initial loading condition of the beam prior to post-tensioning (in-service and overloading), the partial prestressing ratio (0.36 and 0.46), and the load ranges applied to the beam during the fatigue life (39% to 76% of the yield load). The CFRP tendons were post-tensioned at 40% of their ultimate capacity. The monotonic tests of the post-tensioned beams suggested that overloading the beam prior to post-tensioning increased the beam deflections and the strains developed in the steel reinforcing bars at any stage of loading. However, overloading had no significant effect on the yield load of the strengthened beam and the mode of failure at ultimate. It also had no discernable effect on the increase in the tendon stress at yielding. The maximum increase in the CFRP stress at yield load was approximately 20% of the initial post-tensioning stress, for the in-service and overloaded beams. A very good performance of the strengthened beams was observed under fatigue loading. The fatigue life of the beams was mainly governed by the fatigue fracture of the internal steel reinforcing bars at a flexural crack location. Fracture of the bars occurred at the root of a rib where high stress concentration was likely to occur. No evidence of wear or stress concentration were observed at the deviated points of the CFRP tendons due to fatigue. The enhancement in the fatigue life of the strengthened beams was noticeable at all load ranges applied. Post-tensioning considerably decreased the stresses in the steel reinforcing bars and, consequently, increased the fatigue life of the beams. The increase in the fatigue life was slightly affected by the loading history of the beams. At the same load range applied to the beam, increasing the amount of the steel reinforcing bars for the same post-tensioning level decreased the stress range in the bars and significantly increased the fatigue life of the strengthened beams. In the analytical study, a monotonic model that predicts the non-linear flexural response of the CFRP post-tensioned beams was developed and implemented into a computer program. The model takes into account the loading history of the strengthened beams prior to post-tensioning (in-service and overloading). Good agreement was obtained between the measured and the predicted monotonic results. A strain-life based fatigue model was proposed to predict the fatigue life of the CFRP post-tensioned beams. The model takes into consideration the stress-strain history at the stress raisers in the steel bars. It accounts for the inelastic deformation occurring at the ribs during cycling and the resulting changes in the local mean stresses induced. Good agreement between the experimental and predicted fatigue results was observed. A step-by-step fatigue design approach is proposed for the CFRP externally post-tensioned beams. General conclusions of the study and recommendations of future work are given.
5

Spannglasträger – Glasträger mit vorgespannter Bewehrung / Spannglass Beams – Glass Beams with Post-Tensioned Reinforcement

Engelmann, Michael 17 October 2017 (has links) (PDF)
Glas und Beton sind sich in wesentlichen Materialeigenschaften ähnlich: Beide zeigen gegenüber einer hohen Druckfestigkeit eine vergleichsweise geringe Zugfestigkeit und versagen spröde. Diese Analogie führte zur Entwicklung bewehrter Glasträger, die sich durch eine aufgeklebte Stahllasche an ihrer Biegezugkante auszeichnen. Dadurch wurden die Übertragung von Zugkräften auch im Rissfall möglich, sodass ein duktiles Bauteilverhalten erreicht und der im Konstruktiven Glasbau notwendige Nachweis der Resttragfähigkeit erfüllt wird. Glasträger mit verbundlos vorgespannter Bewehrung – Spannglasträger – stellen die Fortführung dieses Analogiegedankens dar. Neben einer gezielten Steigerung der Erstrisslast, können die Träger planmäßig überhöht werden. Damit wird einer bisher üblichen Überdimensionierung mit der Anordnung nicht ausgenutzter „Opferscheiben“ entgegen gewirkt und sichere sowie materialeffiziente Konstruktionen mit maximaler Transparenz ermöglicht. Diese Konstruktionsweise wurde bislang ausschließlich für einzelne Sondierungsuntersuchungen in breiter Variantenvielfalt genutzt. Eine Systematik und einheitliche Bezeichnungsweise ist nicht vorhanden. Darüber hinaus beschränken sich verfügbare Ergebnisse auf die Beschreibung der Tragfähigkeit, ohne die Resttragfähigkeit explizit zu belegen oder die Dauerhaftigkeit nachzuweisen. Mit dieser Arbeit wurde anhand einer Analogiebetrachtung zum Eurocode 2 eine Bezeichnungsweise für bewehrte und vorgespannte Glasträger entwickelt und für vorhandene Konstruktionen erfolgreich angewendet. Darin zeigt sich, dass der Stand der Technik auf diese Weise charakterisierbar ist. Zusätzlich wird die These aufgestellt, dass sich das Tragverhalten von Spannglasträgern wie im Stahlbeton- und Spannbetonbau beschreiben und die auftretenden Spannkraftverluste analog berechnen lassen. Diese These wird mithilfe experimenteller Studien als Kern dieser Arbeit untersucht und durch eine ergänzende numerische Modellierung bestätigt. Zunächst wird das Tragverhalten im Kurzzeit-Biegeversuch an 15 Prüfkörpern unter variierten Bewehrungsgraden und Vorspannkräften untersucht. Dabei zeigen sich gesteigerte Erstrisslasten sowie ein sicheres Verhalten im Anschluss an die Belastung. Durch die Vorspannung wird das Tragverhalten gezielt beeinflusst. Zusätzlich erbringt eine zerstörungsfreie Untersuchungsreihe an 28 Prüfkörpern unter konstanter Gebrauchslast über 1000 Stunden erstmals eine Beschreibung der auftretenden Spannkraftverluste. Diese sind maßgeblich von der horizontalen Durchbiegung sowie der daraus resultierenden Belastung der Zwischenschicht im Verbund-Sicherheitsglas abhängig. Aus der Größenordnung der Verluste lässt sich schlussfolgern, dass eine Begrenzung dieses Verformungsanteils sowie eine konstruktive Entlastung der Zwischenschicht notwendig sind. Zudem wird die Änderung der Vorspannkraft unter einer Temperaturlast beschrieben. Im Ergebnis zeigt sich, dass dieser Lastfall mittels der linearen Balkentheorie beschreibbar und der damit assoziierte Spannkraftverlust berechenbar ist. Die Resttragfähigkeit von 24 Spannglasträgern wird mithilfe eines eigens entwickelten Prüfverfahrens bestätigt. Während die Bewehrung einerseits eine Überbrückung von Rissflanken ermöglicht, verursacht die Vorspannkraft andererseits im teilzerstörten Tragsystem bisweilen ein frühzeitiges Versagen. Daher wird empfohlen, die baukonstruktive Detailentwicklung zu intensivieren, um einen größeren Sicherheitsvorteil aus der Konstruktionsweise zu generieren. Die Arbeit beinhaltet erstmals eine systematische Datensammlung zum Tragverhalten von Spannglasträgern. Es zeigt sich, dass auf eine Anordnung von „Opferscheiben“ zugunsten einer steigenden Materialeffizienz nicht nur verzichtet werden kann, sondern im Sinne eines effektiven Tragverhaltens verzichtet werden muss. Mit der vorgeschlagenen Bezeichnungsweise, den abgeleiteten konstruktiven Maßnahmen sowie den gezeigten Untersuchungsmethoden besteht nunmehr die Möglichkeit, sichere und dauerhafte Spannglasträger zu entwerfen und deren Trageffizienz zu belegen. / Glass and concrete share essential material characteristics: Their compressive strength exceeds their tensile strength considerably and both of them fail in a brittle manner. This analogy led to the development of reinforced glass beams, which are improved by means of adhesively bonded steel sections in the tensile zone. This improvement allowed for a direct transfer of tensile loads in a post-breakage state and resulted in a ductile structural element, which met the special demand of structural glass for a sufficient residual loadbearing capacity. Glass beams with unbonded, post-tensioned reinforcement – Spannglass Beams – carry this analogy concept on. The members will comprise an increased initial fracture strength and may be uplifted intentionally. This development has rendered the need for over-dimensioning by removing unnecessary sacrificial layers, which will result in a material efficient structure and will maximise transparency. Solely single exploratory investigations have used this idea in a wide variety of options so far. There is neither a uniform classification nor a consistent nomenclature. Furthermore, available results are limited to the concise description of the short-term load-bearing properties without proving the residual load-bearing capacity explicitly and confirming longterm durability. This thesis describes the development and the application of a nomenclature for reinforced and pre-compressed glass beams in an analogy study according to Eurocode 2. The state of technology can be characterised in this manner. Additionally, the research describes the load-bearing behaviour as well as the calculation of the loss of pre-stress of Spannglass Beams by analogy with concrete structures. As the key section of this thesis, this statement is examined by means of comprehensive experimental studies and completed by a numerical calculation. Primarily, the load-bearing behaviour of 15 specimens in short-term bending tests and a variety of reinforcement ratios and pre-stress levels were determined. The results show an increase of initial fracture strength as well as safe behaviour after failure. The pre-stress changes the load-bearing performance significantly. Furthermore, a non-destructive study including a constant loading for 1000 h describes the loss of pre-stress in 28 specimens for the first time. The horizontal deflection and the thus resulting shear stresses of the interlayer material of a laminated glass section are the critical parameters. From the magnitude of losses it may be concluded that the deflections need to be limited and the interlayer foils need to be relieved from stress. Moreover, the structural response during a change in temperature is in good agreement with the results obtained from linear beam theory. This allows for an estimation of the associated losses. Finally, a specifically developed test approach confirms the residual load-bearing capacity of 24 specimens. The reinforcement shows the ability to bridge cracks in the glass. However, it should be noted that pre-stress occasionally causes an early failure of the partially broken Spannglass cross-section. Therefore, intensifying the development of structural details in order to generate an increased advantage concerning safety is recommended. This contribution contains a systematic acquisition of analytical, experimental and numerical data regarding the loadbearing characteristics of Spannglass Beams for the first time. The use of a sacrificial layers is not necessary. Even more, to reach the most effective load-bearing behaviour, it is necessary to abandon them completely. Implementing the developed nomenclature, realising the recommended structural provisions and using the proposed methods, it is now possible to compose safe and durable Spannglass Beams as well as prove their structural efficiency.
6

Spannglasträger – Glasträger mit vorgespannter Bewehrung

Engelmann, Michael 24 August 2017 (has links)
Glas und Beton sind sich in wesentlichen Materialeigenschaften ähnlich: Beide zeigen gegenüber einer hohen Druckfestigkeit eine vergleichsweise geringe Zugfestigkeit und versagen spröde. Diese Analogie führte zur Entwicklung bewehrter Glasträger, die sich durch eine aufgeklebte Stahllasche an ihrer Biegezugkante auszeichnen. Dadurch wurden die Übertragung von Zugkräften auch im Rissfall möglich, sodass ein duktiles Bauteilverhalten erreicht und der im Konstruktiven Glasbau notwendige Nachweis der Resttragfähigkeit erfüllt wird. Glasträger mit verbundlos vorgespannter Bewehrung – Spannglasträger – stellen die Fortführung dieses Analogiegedankens dar. Neben einer gezielten Steigerung der Erstrisslast, können die Träger planmäßig überhöht werden. Damit wird einer bisher üblichen Überdimensionierung mit der Anordnung nicht ausgenutzter „Opferscheiben“ entgegen gewirkt und sichere sowie materialeffiziente Konstruktionen mit maximaler Transparenz ermöglicht. Diese Konstruktionsweise wurde bislang ausschließlich für einzelne Sondierungsuntersuchungen in breiter Variantenvielfalt genutzt. Eine Systematik und einheitliche Bezeichnungsweise ist nicht vorhanden. Darüber hinaus beschränken sich verfügbare Ergebnisse auf die Beschreibung der Tragfähigkeit, ohne die Resttragfähigkeit explizit zu belegen oder die Dauerhaftigkeit nachzuweisen. Mit dieser Arbeit wurde anhand einer Analogiebetrachtung zum Eurocode 2 eine Bezeichnungsweise für bewehrte und vorgespannte Glasträger entwickelt und für vorhandene Konstruktionen erfolgreich angewendet. Darin zeigt sich, dass der Stand der Technik auf diese Weise charakterisierbar ist. Zusätzlich wird die These aufgestellt, dass sich das Tragverhalten von Spannglasträgern wie im Stahlbeton- und Spannbetonbau beschreiben und die auftretenden Spannkraftverluste analog berechnen lassen. Diese These wird mithilfe experimenteller Studien als Kern dieser Arbeit untersucht und durch eine ergänzende numerische Modellierung bestätigt. Zunächst wird das Tragverhalten im Kurzzeit-Biegeversuch an 15 Prüfkörpern unter variierten Bewehrungsgraden und Vorspannkräften untersucht. Dabei zeigen sich gesteigerte Erstrisslasten sowie ein sicheres Verhalten im Anschluss an die Belastung. Durch die Vorspannung wird das Tragverhalten gezielt beeinflusst. Zusätzlich erbringt eine zerstörungsfreie Untersuchungsreihe an 28 Prüfkörpern unter konstanter Gebrauchslast über 1000 Stunden erstmals eine Beschreibung der auftretenden Spannkraftverluste. Diese sind maßgeblich von der horizontalen Durchbiegung sowie der daraus resultierenden Belastung der Zwischenschicht im Verbund-Sicherheitsglas abhängig. Aus der Größenordnung der Verluste lässt sich schlussfolgern, dass eine Begrenzung dieses Verformungsanteils sowie eine konstruktive Entlastung der Zwischenschicht notwendig sind. Zudem wird die Änderung der Vorspannkraft unter einer Temperaturlast beschrieben. Im Ergebnis zeigt sich, dass dieser Lastfall mittels der linearen Balkentheorie beschreibbar und der damit assoziierte Spannkraftverlust berechenbar ist. Die Resttragfähigkeit von 24 Spannglasträgern wird mithilfe eines eigens entwickelten Prüfverfahrens bestätigt. Während die Bewehrung einerseits eine Überbrückung von Rissflanken ermöglicht, verursacht die Vorspannkraft andererseits im teilzerstörten Tragsystem bisweilen ein frühzeitiges Versagen. Daher wird empfohlen, die baukonstruktive Detailentwicklung zu intensivieren, um einen größeren Sicherheitsvorteil aus der Konstruktionsweise zu generieren. Die Arbeit beinhaltet erstmals eine systematische Datensammlung zum Tragverhalten von Spannglasträgern. Es zeigt sich, dass auf eine Anordnung von „Opferscheiben“ zugunsten einer steigenden Materialeffizienz nicht nur verzichtet werden kann, sondern im Sinne eines effektiven Tragverhaltens verzichtet werden muss. Mit der vorgeschlagenen Bezeichnungsweise, den abgeleiteten konstruktiven Maßnahmen sowie den gezeigten Untersuchungsmethoden besteht nunmehr die Möglichkeit, sichere und dauerhafte Spannglasträger zu entwerfen und deren Trageffizienz zu belegen.:1 Einleitung 1.1 Problemstellung und Motivation 1.2 Zielsetzung 1.3 Vorgehensweise 1.4 Abgrenzung 2 Analogiebetrachtung 2.1 Zielsetzung 2.2 Anwendungsbereich 2.3 Begriffe 2.3.1 Bewehrte und hybride Glastragwerke 2.3.2 Thermische und mechanische Vorspannung 2.3.3 Spanngliedkonstruktion und Spannverfahren 2.3.4 Lage und Verlauf des Spanngliedes 2.3.5 Weitere Begriffe 2.4 Grundlagen der Tragwerksplanung 2.5 Baustoffe 2.5.1 Festigkeit 2.5.2 Elastische Formänderungseigenschaften 2.5.3 Kriechen und Schwinden 2.5.4 Bewehrungsmaterial 2.5.5 Komponenten von Spannsystemen 2.5.6 Querschnittsgestaltung 2.6 Dauerhaftigkeit 2.7 Schnittgrößenermittlung 2.7.1 Allgemeines 2.7.2 Imperfektionen 2.7.3 Idealisierung 2.7.4 Lineare Berechnung 2.7.5 Nichtlineare Berechnung 2.7.6 Zeitabhängigkeit der Vorspannkraft 2.7.7 Vorspannung während der Berechnung 2.8 Grenzzustände und Nachweise 2.8.1 Grenzzustand der Tragfähigkeit 2.8.2 Grenzzustand der Gebrauchstauglichkeit 2.8.3 Nachweis der Resttragfähigkeit 2.9 Bewehrungs- und Konstruktionsregeln 2.10 Zusammenfassung 3 Experimentelle Untersuchungen 3.1 Zielsetzung 3.2 Prüfkörper – Konstruktion und Materialien 3.3 Tragverhalten unter kurzzeitiger Beanspruchung 3.3.1 Prüfkörper 3.3.2 Versuchseinrichtung 3.3.3 Untersuchungsverfahren und -bedingungen 3.3.4 Analyse- und Auswertungsverfahren 3.3.5 Ergebnisse und Ergebnisdiskussion 3.3.6 Folgerungen und Zusammenfassung 3.4 Tragverhalten unter Dauerlast 3.4.1 Prüfkörper 3.4.2 Versuchseinrichtung 3.4.3 Untersuchungsverfahren und -bedingungen 3.4.4 Analyse- und Auswertungsverfahren 3.4.5 Ergebnisse und Ergebnisdiskussion 3.4.6 Folgerungen und Zusammenfassung 3.5 Resttragfähigkeit 3.5.1 Prüfkörper 3.5.2 Versuchseinrichtung 3.5.3 Untersuchungsverfahren und -bedingungen 3.5.4 Analyse- und Auswertungsverfahren 3.5.5 Ergebnisse und Ergebnisdiskussion 3.5.6 Folgerungen und Zusammenfassung 3.6 Tragverhalten unter Temperaturbelastung 3.6.1 Prüfkörper 3.6.2 Versuchseinrichtung 3.6.3 Untersuchungsverfahren und -bedingungen 3.6.4 Analyse- und Auswertungsverfahren 3.6.5 Ergebnisse und Ergebnisdiskussion 3.6.6 Folgerungen und Zusammenfassung 3.7 Zusammenfassung 4 Numerische Untersuchungen 4.1 Zielsetzung 4.2 Modellbeschreibung 4.2.1 Systembeschreibung 4.2.2 Einwirkungen 4.2.3 Berechnung 4.3 Ergebnisse und Ergebnisdiskussion 4.3.1 Vergleich mit dem analytischen Modell 4.3.2 Modellierung der Umlenkung 4.3.3 Einfluss der Zwischenschicht 4.3.4 Auswahl eines Imperfektionswertes 4.3.5 Seilkraftverlust im Dauerversuch 4.4 Zusammenfassung 5 Diskussion 5.1 Zielsetzung 5.2 Tragverhalten unter kurzzeitiger Beanspruchung 5.2.1 Tragverhalten unter Vorspannbelastung 5.2.2 Trag- und Bruchverhalten unter Biegebelastung 5.2.3 Rissverhalten unter Biegebelastung 5.2.4 Spannungszuwachs in der Bewehrung 5.3 Tragverhalten unter Dauerbelastung 5.4 Resttragfähigkeit 5.5 Zusammenfassung 6 Konstruktive Empfehlungen 6.1 Zielsetzung 6.2 Teilprojekte 6.2.1 Forschungsprojekt „Glasträger mit Bewehrung“ 6.2.2 Spannglasbrücke – glasstec 2014 6.2.3 Fußgängerbrücke in Nara (Japan) 2015 6.3 Verankerungen 6.3.1 Tragfähigkeit der Verankerung 6.3.2 Seilkrafteinleitung 6.3.3 Toleranzausgleich 6.3.4 Neigungsausgleich 6.4 Vorspannverfahren 6.5 Umlenkpunkte 6.5.1 Geklotzte Umlenkpunkte 6.5.2 Geklebte Umlenkpunkte 6.6 Montage 6.7 Weiterführende Konstruktionen 6.7.1 Spannglasträger mit nachträglichem Verbund 6.7.2 Segmentbauweise 6.8 Zusammenfassung 7 Zusammenfassung und Ausblick 7.1 Zusammenfassung 7.2 Ausblick 8 Literatur 8.1 Fachbücher und Fachaufsätze 8.2 Normen und Richtlinien Bezeichnungen Abbildungsverzeichnis und -nachweis Tabellenverzeichnis A Analytische Schnittgrößenberechnung B Kurzzeit-Biegeversuche C Dauerversuche 1000 h D Versuche zur Resttragfähigkeit E Biegeversuche unter Temperaturlast F SOFiSTiK Quelltext / Glass and concrete share essential material characteristics: Their compressive strength exceeds their tensile strength considerably and both of them fail in a brittle manner. This analogy led to the development of reinforced glass beams, which are improved by means of adhesively bonded steel sections in the tensile zone. This improvement allowed for a direct transfer of tensile loads in a post-breakage state and resulted in a ductile structural element, which met the special demand of structural glass for a sufficient residual loadbearing capacity. Glass beams with unbonded, post-tensioned reinforcement – Spannglass Beams – carry this analogy concept on. The members will comprise an increased initial fracture strength and may be uplifted intentionally. This development has rendered the need for over-dimensioning by removing unnecessary sacrificial layers, which will result in a material efficient structure and will maximise transparency. Solely single exploratory investigations have used this idea in a wide variety of options so far. There is neither a uniform classification nor a consistent nomenclature. Furthermore, available results are limited to the concise description of the short-term load-bearing properties without proving the residual load-bearing capacity explicitly and confirming longterm durability. This thesis describes the development and the application of a nomenclature for reinforced and pre-compressed glass beams in an analogy study according to Eurocode 2. The state of technology can be characterised in this manner. Additionally, the research describes the load-bearing behaviour as well as the calculation of the loss of pre-stress of Spannglass Beams by analogy with concrete structures. As the key section of this thesis, this statement is examined by means of comprehensive experimental studies and completed by a numerical calculation. Primarily, the load-bearing behaviour of 15 specimens in short-term bending tests and a variety of reinforcement ratios and pre-stress levels were determined. The results show an increase of initial fracture strength as well as safe behaviour after failure. The pre-stress changes the load-bearing performance significantly. Furthermore, a non-destructive study including a constant loading for 1000 h describes the loss of pre-stress in 28 specimens for the first time. The horizontal deflection and the thus resulting shear stresses of the interlayer material of a laminated glass section are the critical parameters. From the magnitude of losses it may be concluded that the deflections need to be limited and the interlayer foils need to be relieved from stress. Moreover, the structural response during a change in temperature is in good agreement with the results obtained from linear beam theory. This allows for an estimation of the associated losses. Finally, a specifically developed test approach confirms the residual load-bearing capacity of 24 specimens. The reinforcement shows the ability to bridge cracks in the glass. However, it should be noted that pre-stress occasionally causes an early failure of the partially broken Spannglass cross-section. Therefore, intensifying the development of structural details in order to generate an increased advantage concerning safety is recommended. This contribution contains a systematic acquisition of analytical, experimental and numerical data regarding the loadbearing characteristics of Spannglass Beams for the first time. The use of a sacrificial layers is not necessary. Even more, to reach the most effective load-bearing behaviour, it is necessary to abandon them completely. Implementing the developed nomenclature, realising the recommended structural provisions and using the proposed methods, it is now possible to compose safe and durable Spannglass Beams as well as prove their structural efficiency.:1 Einleitung 1.1 Problemstellung und Motivation 1.2 Zielsetzung 1.3 Vorgehensweise 1.4 Abgrenzung 2 Analogiebetrachtung 2.1 Zielsetzung 2.2 Anwendungsbereich 2.3 Begriffe 2.3.1 Bewehrte und hybride Glastragwerke 2.3.2 Thermische und mechanische Vorspannung 2.3.3 Spanngliedkonstruktion und Spannverfahren 2.3.4 Lage und Verlauf des Spanngliedes 2.3.5 Weitere Begriffe 2.4 Grundlagen der Tragwerksplanung 2.5 Baustoffe 2.5.1 Festigkeit 2.5.2 Elastische Formänderungseigenschaften 2.5.3 Kriechen und Schwinden 2.5.4 Bewehrungsmaterial 2.5.5 Komponenten von Spannsystemen 2.5.6 Querschnittsgestaltung 2.6 Dauerhaftigkeit 2.7 Schnittgrößenermittlung 2.7.1 Allgemeines 2.7.2 Imperfektionen 2.7.3 Idealisierung 2.7.4 Lineare Berechnung 2.7.5 Nichtlineare Berechnung 2.7.6 Zeitabhängigkeit der Vorspannkraft 2.7.7 Vorspannung während der Berechnung 2.8 Grenzzustände und Nachweise 2.8.1 Grenzzustand der Tragfähigkeit 2.8.2 Grenzzustand der Gebrauchstauglichkeit 2.8.3 Nachweis der Resttragfähigkeit 2.9 Bewehrungs- und Konstruktionsregeln 2.10 Zusammenfassung 3 Experimentelle Untersuchungen 3.1 Zielsetzung 3.2 Prüfkörper – Konstruktion und Materialien 3.3 Tragverhalten unter kurzzeitiger Beanspruchung 3.3.1 Prüfkörper 3.3.2 Versuchseinrichtung 3.3.3 Untersuchungsverfahren und -bedingungen 3.3.4 Analyse- und Auswertungsverfahren 3.3.5 Ergebnisse und Ergebnisdiskussion 3.3.6 Folgerungen und Zusammenfassung 3.4 Tragverhalten unter Dauerlast 3.4.1 Prüfkörper 3.4.2 Versuchseinrichtung 3.4.3 Untersuchungsverfahren und -bedingungen 3.4.4 Analyse- und Auswertungsverfahren 3.4.5 Ergebnisse und Ergebnisdiskussion 3.4.6 Folgerungen und Zusammenfassung 3.5 Resttragfähigkeit 3.5.1 Prüfkörper 3.5.2 Versuchseinrichtung 3.5.3 Untersuchungsverfahren und -bedingungen 3.5.4 Analyse- und Auswertungsverfahren 3.5.5 Ergebnisse und Ergebnisdiskussion 3.5.6 Folgerungen und Zusammenfassung 3.6 Tragverhalten unter Temperaturbelastung 3.6.1 Prüfkörper 3.6.2 Versuchseinrichtung 3.6.3 Untersuchungsverfahren und -bedingungen 3.6.4 Analyse- und Auswertungsverfahren 3.6.5 Ergebnisse und Ergebnisdiskussion 3.6.6 Folgerungen und Zusammenfassung 3.7 Zusammenfassung 4 Numerische Untersuchungen 4.1 Zielsetzung 4.2 Modellbeschreibung 4.2.1 Systembeschreibung 4.2.2 Einwirkungen 4.2.3 Berechnung 4.3 Ergebnisse und Ergebnisdiskussion 4.3.1 Vergleich mit dem analytischen Modell 4.3.2 Modellierung der Umlenkung 4.3.3 Einfluss der Zwischenschicht 4.3.4 Auswahl eines Imperfektionswertes 4.3.5 Seilkraftverlust im Dauerversuch 4.4 Zusammenfassung 5 Diskussion 5.1 Zielsetzung 5.2 Tragverhalten unter kurzzeitiger Beanspruchung 5.2.1 Tragverhalten unter Vorspannbelastung 5.2.2 Trag- und Bruchverhalten unter Biegebelastung 5.2.3 Rissverhalten unter Biegebelastung 5.2.4 Spannungszuwachs in der Bewehrung 5.3 Tragverhalten unter Dauerbelastung 5.4 Resttragfähigkeit 5.5 Zusammenfassung 6 Konstruktive Empfehlungen 6.1 Zielsetzung 6.2 Teilprojekte 6.2.1 Forschungsprojekt „Glasträger mit Bewehrung“ 6.2.2 Spannglasbrücke – glasstec 2014 6.2.3 Fußgängerbrücke in Nara (Japan) 2015 6.3 Verankerungen 6.3.1 Tragfähigkeit der Verankerung 6.3.2 Seilkrafteinleitung 6.3.3 Toleranzausgleich 6.3.4 Neigungsausgleich 6.4 Vorspannverfahren 6.5 Umlenkpunkte 6.5.1 Geklotzte Umlenkpunkte 6.5.2 Geklebte Umlenkpunkte 6.6 Montage 6.7 Weiterführende Konstruktionen 6.7.1 Spannglasträger mit nachträglichem Verbund 6.7.2 Segmentbauweise 6.8 Zusammenfassung 7 Zusammenfassung und Ausblick 7.1 Zusammenfassung 7.2 Ausblick 8 Literatur 8.1 Fachbücher und Fachaufsätze 8.2 Normen und Richtlinien Bezeichnungen Abbildungsverzeichnis und -nachweis Tabellenverzeichnis A Analytische Schnittgrößenberechnung B Kurzzeit-Biegeversuche C Dauerversuche 1000 h D Versuche zur Resttragfähigkeit E Biegeversuche unter Temperaturlast F SOFiSTiK Quelltext

Page generated in 0.3434 seconds