91 |
Multi-item Inventory-routing Problem For An Fmcg CompanyZerman, Erel 01 October 2007 (has links) (PDF)
In this study, inventory&ndash / routing system of a company operating in Fast Moving Consumer Goods (FMCG) industry is analyzed. The company has decided to redesign distribution system by locating regional warehouses between production plants and customers. The warehouses in the system are all allowed to hold stock without any capacity restriction. The customers are replenished by the warehouse to which they have been assigned. Customer stocks are continuously monitored by the warehouse and deliveries are to be scheduled. In this multi&ndash / item, two-echelon inventory&ndash / distribution system, main problem is synchronizing inventory and distribution decisions. An integrated Mixed Integer Programming optimization model for inventory and distribution planning is proposed with the aim of optimally coordinating inventory management and vehicle routing. The model determines the replenishment periods of items and amount of delivery to each customer / and constructs the delivery routes with the objective of cost minimization. The integrated model is coded in GAMS and solved by CPLEX. The integrated inventory-routing model is simulated with retrospective data of the company. Computational results on test problems are provided to show the effectiveness of the model developed in terms of the performance measures defined. Moreover, the feasible solution obtained for a period is compared to the realized inventory levels and distribution schedules. Computational results seem to indicate a substantial advantage of the integrated inventory-routing system over the existing distribution system.
|
92 |
Development of a Simulation Module for the Reliability Computer Program RADPOWSetréus, Johan January 2006 (has links)
<p>Detta examensarbete beskriver hur en Monte Carlo simulering (MCS) kan användas för tillförlitlighetsanalys av ett eldistributionssystem. Metoden har implementerats i verktyget RADPOW som nu kan utföra både analytiska och numeriska beräkningar. Angreppssättet för att utveckla denna MCS metod i RADPOW innefattade följande aktiviteter:</p><p>• Vidareutvecklade av RADPOW med införandet av ett grafiskt användargränssnitt för Windows.</p><p>• Utveckling och implementering av en iterativ analytisk metod för känslighetsanalys av eldistributionssystem i RADPOW.</p><p>• Utveckling och implementering av MCS metoden i RADPOW, vilken placerades i en fristående modul kallad Sim.</p><p>Den implementerade MCS metoden har validerats i en jämförande studie innefattande två testsystem med datorprogrammet NEPLAN. Resultat från denna studie visar att MCS metoden ger samma resultat som den analytiska metoden i RADPOW och det kommersiella verktyget NEPLAN.</p> / <p>This master thesis describes an implementation of a Monte Carlo Simulation (MCS) method for reliability assessment of electrical distribution systems. The method has been implemented in the reliability assessment tool RADPOW which now is able to perform both analytical and simulation evaluations. The main contributions within this thesis includes the following activities;</p><p>• Further development of RADPOW by the introducing of a graphical user interface for Windows.</p><p>• Development and implementation of an analytical sensitivity analysis routine for RADPOW.</p><p>• Development and implementation of a sequential MCS method in RADPOW in a stand alone module referred to as Sim.</p><p>The implemented MCS method has been validated in a comparable study for two case systems by a commercial software NEPLAN. Results shows that the implemented MCS method provides the same results as the analytical method in RADPOW and the NEPLAN software.</p>
|
93 |
Myopic Allocation in Two-level Distribution Systems with Continuous Review and Time Based DispatchingHoward, Christian January 2007 (has links)
<p>This thesis studies the allocation of stock in a two-level inventory system with stochastic demand. The system consists of one central warehouse which supplies N non-identical retailers with one single product. Customer demand occurs solely at the retailers and follows independent Poisson processes. The purpose is to investigate the value of using a more advanced allocation policy than First Come-First Serve at the central warehouse. The focus is on evaluating how well the simple First Come-First Serve assumption works in a system where the warehouse has access to real-time point-of-sale data, and where shipments are time based and consolidated for all retailers. The considered allocation policy is a myopic policy where the solution to a minimization problem, formulated as a constrained newsvendor problem, determines how the warehouse allocates its stock to the retailers. The minimization problem is solved using (a heuristic method based on) Lagrangian relaxation, and simulation is used to evaluate the average inventory holding costs and backorder costs per time unit when using the considered policy. The simulation study shows that cost savings around 1-4 percent can be expected for most system configurations. However, there were cases where savings were as high as 5 percent, as well as cases where the policy performed worse than First Come-First Serve. The study also shows that the highest cost savings are found in systems with relatively low demand, few retailers, short transportation times and a short time interval between shipments.</p>
|
94 |
The effect of distribution systems on household drinking water quality in Addis Ababa, Ethiopia, and Christchurch, New ZealandMekonnen, Dawit Kidane January 2015 (has links)
Access to clean and safe drinking water is a fundamental human requirement. However, in many areas of the world natural water sources have been impacted by a variety of biological and chemical contaminants. The ingestion of these contaminants may cause acute or chronic health problems. To prevent such illnesses, many technologies have been developed to treat, disinfect and supply safe drinking water quality. However, despite these advancements, water supply distribution systems can adversely affect the drinking water quality before it is delivered to consumers. The primary aim of this research was to investigate the effect that water distribution systems may have on household drinking water quality in Christchurch, New Zealand and Addis Ababa, Ethiopia. Water samples were collected from the source water and household taps in both cities. The samples were then tested for various physical, chemical and biological water quality parameters. The data collected was also used to determine if water samples complied with national drinking water quality standards in both countries. Independent samples t-test statistical analyses were also performed to determine if water quality measured in the samples collected from the source and household taps was significantly different.
Water quality did not vary considerably between the source and tap water samples collected in Christchurch City. No bacteria were detected in any sample. However, the pH and total iron concentrations measured in source and tap water samples were found to be significantly different. The lower pH values measured in tap water samples suggests that corrosion may be taking place in the distribution system. No water samples transgressed the Drinking Water Standards for New Zealand (DWSNZ) MAVs. Monitoring data collected by the Christchurch City Council (CCC) was also used for comparison. A number of pH, turbidity and total iron concentration measurements collected by the CCC in 2011 were found to exceed the guideline values. This is likely due to structural damage to the source wells and pump-stations that occurred during the 2011 earthquake events. Overall, it was concluded that the distribution system does not adversely affect the quality of Christchurch City’s household drinking water.
The water quality measured in samples collected from the source (LTP) and household taps in Addis Ababa was found to vary considerably. The water collected from the source complied with the Ethiopian (WHO) drinking water quality standards. However, tap water samples were often found to have degraded water quality for the physical and chemical parameters tested.
This was especially the case after supply interruption and reinstatement events. Bacteria were also often detected in household tap water samples. The results from this study indicate that water supply disruptions may result in degraded water quality. This may be due to a drop in pipeline pressure and the intrusion of contaminants through the leaky and cross-connected pipes in the distribution network. This adversely affects the drinking water quality in Addis Ababa.
|
95 |
Modeling and simulation of distribution system components in anticipation of a smarter electric power gridToliyat, Amir 11 July 2011 (has links)
Successful development of the electric power grid of the future, hereinafter referred to as a smart grid, implicitly demands the capability to model the behavior, performance, and cost of distribution-level smart grid components. The modeling and simulation of such individual components, together with their overall interaction, will provide a foundation for the design and configuration of a smart grid.
It is the primary intent of this thesis, to provide a basic insight into the energy transfer of various distribution-level components by modeling and simulating their dynamic behavior. The principal operations of a smart grid must be considered, including variable renewable generation, energy storage, power electronic interfaces, variable load, and plug-in electric vehicles. The methodology involves deriving the mathematical equations of components, and, using the MATLAB/Simulink environment, creating modules for each component. Ultimately, these individual modules may be connected together via a voltage interface to perform various analyses, such as the treatment of harmonics, or to acquire an understanding of design parameters such as capacity, runtime, and optimal asset utilization. / text
|
96 |
New Analysis and Operational Control Algorithms for Islanded Microgrid SystemsAbdelaziz, Morad Mohamed Abdelmageed January 2014 (has links)
Driven by technical, economic and environmental benefits for different stakeholders in the power industry, the electric distribution system is currently undergoing a major paradigm shift towards having an increasing portion of its growing demand supplied via distributed generation (DG) units. As the number of DG units increase; microgrids can be defined within the electric distribution system as electric regions with enough generation to meet all or most of its local demand. A microgrid should be able to operate in two modes, grid-connected or islanded. The IEEE standard 1547.4 enumerates a list of potential benefits for the islanded microgrid operation. Such benefits include: 1) improving customers’ reliability, 2) relieving electric power system overload problems, 3) resolving power quality issues, and 4) allowing for maintenance of the different power system components without interrupting customers. These benefits motivate the operation of microgrid systems in the islanded mode. However the microgrid isolation from the main grid creates special technical challenges that have to be comprehensively investigated in order to facilitate a successful implementation of the islanded microgrid concept.
Motivated by these facts, the target of this thesis is to introduce new analysis and operational control algorithms to tackle some of the challenges associated with the practical implementation of the islanded microgrid concept. In order to accomplish this target, this study is divided into four perspectives: 1) developing an accurate steady-state analysis algorithm for islanded microgrid systems, 2) maximizing the possible utilization of islanded microgrid limited generation resources, 3) allowing for the decentralized operation of islanded microgrid systems and 4) enabling the islanded microgrid operation in distribution systems with high penetration of plug-in electric vehicles (PEVs).
First for the steady-state analysis of islanded microgrid systems, a novel and generalized algorithm is proposed to provide accurate power flow analysis of islanded microgrid systems. Conventional power flow tools found in the literature are generally not suitable for the islanded microgrid operating mode. The reason is that none of these tools reflect the islanded microgrid special philosophy of operation in the absence of the utility bus. The proposed algorithm adopts the real characteristics of the islanded microgrid operation; i.e., 1) Some of the DG units are controlled using droop control methods and their generated active and reactive power are dependent on the power flow variables and cannot be pre-specified; 2) The steady-state system frequency is not constant and is considered as one of the power flow variables. The proposed algorithm is generic, where the features of distribution systems i.e. three-phase feeder models, unbalanced loads and load models have been taken in consideration. The effectiveness of the proposed algorithm, in providing accurate steady-state analysis of islanded microgrid systems, is demonstrated through several case studies.
Secondly, this thesis proposes the consideration of a system maximum loadability criterion in the optimal power flow (OPF) problem of islanded microgrid systems. Such consideration allows for an increased utilization of the islanded microgrid limited generation resources when in isolation from the utility grid. Three OPF problem formulations for islanded microgrids are proposed; 1) The OPF problem for maximum loadability assessment, 2) The OPF for maximizing the system loadability, and 3) The bi-objective OPF problem for loadability maximization and generation cost minimization. An algorithm to achieve a best compromise solution between system maximum loadability and minimum generation costs is also proposed. A detailed islanded microgrid model is adopted to reflect the islanded microgrid special features and real operational characteristics in the proposed OPF problem formulations. The importance and consequences of considering the system maximum loadability in the operational planning of islanded microgrid systems are demonstrated through comparative numerical studies.
Next, a new probabilistic algorithm for enabling the decentralized operation of islanded microgrids, including renewable resources, in the absence of a microgrid central controller (MGCC) is proposed. The proposed algorithm adopts a constraint hierarchy approach to enhance the operation of islanded microgrids by satisfying the system’s operational constraints and expanding its loading margin. The new algorithm takes into consideration the variety of possible islanded microgrid configurations that can be initiated in a distribution network (multi-microgrids), the uncertainty and variability associated with the output power of renewable DG units as well as the variability of the load, and the special operational philosophy associated with islanded microgrid systems. Simulation studies show that the proposed algorithm can facilitate the successful implementation of the islanded microgrid concept by reducing customer interruptions and enhancing the islanded microgrid loadability margins.
Finally, this research proposes a new multi-stage control scheme to enable the islanded microgrid operation in the presence of high PEVs penetration. The proposed control scheme optimally coordinates the DG units operation, the shedding of islanded microgrid power demand (during inadequate generation periods) and the PEVs charging/discharging decisions. To this end, a three-stage control scheme is formulated in order to: 1) minimize the load shedding, 2) satisfy the PEVs customers’ requirements and 3) minimize the microgrid cost of operation. The proposed control scheme takes into consideration; the variability associated with the output power of renewable DG units, the random behaviour of PEV charging and the special features of islanded microgrid systems. The simulation studies show that the proposed control scheme can enhance the operation of islanded microgrid systems in the presence of high PEVs penetration and facilitate a successful implementation of the islanded microgrid concept, under the smart grid paradigm.
|
97 |
Adapting to the Changes Enforced by EU’s Network Codes for Electricity : The Consequences for an Electricity Company from a Distribution System Operator’s PerspectiveFalk, Karolina, Forsberg, Joel January 2014 (has links)
To reach EU’s climate and energy target an integrated electricity market is considered to be required (Klessmann, et al., 2011; Boie, et al., 2014; Becker, et al., 2013). As a result the European Commission decided to form a set of rules, named the Network Codes, to create a single European market (ENTSO-E, 2013b). The Network Codes will affect Distribution- and Transmission System Operators, grid users and production units as well as all the other actors on the electricity market (Eurelectric, n.d.a). Concerns regarding what the Network Codes’ actual consequences are have been expressed within the line of business (Swedish Energy, 2013a). Therefore the purpose of this master’s thesis was to determine and furthermore illustrate the consequences the Network Codes will have, in current version, for a Swedish non-transmission system connected electricity company and determine what actions need to be taken. The purpose has been addressed by conducting interviews, document studies and by utilizing a change management model, the Intervention Strategy Model, introduced by Paton & McCalman (2000). The structured approach that is the nature of the model was used when determining the consequences the Network Codes enforce and what actions a non-transmission system connected electricity company has to take to cope with them. To further facilitate the determination of these actions this study was conducted on a non-transmission system connected electricity company, in this thesis named Electricity Company A. The investigation of the concerns expressed within the line of business illustrated that the concerns were diverse but a majority of them might be incorporated into either of the following groups, simulation models, demand side aggregator and information handling. Out of these groups information handling was by far the area of greatest concern with issues primarily connected to the Distribution System Operator. Consequently this thesis focused on the Distribution System Operator’s perspective. The analysis of the area of greatest concern, presented in two flow charts, clearly showed the increased amount of communication enforced by the Network Codes. This increased information handling results in numerous possible organisational consequences for the Distribution System Operator, for example might new systems be required and some existing systems be used with or without adaption. Furthermore, the extra workload could possibly be handled by the existing personnel, in some cases after complementary education, but it might also require new personnel. Finally the Network Codes open up for the possibility for the Distribution System Operator to define certain details which may be conducted individually or in cooperation with other Distribution System Operators. Which of these possible consequences that will affect a specific company is, however, dependent on its preconditions. The study on Electricity Company A reveals that the numerous actions required to handle the new communication were not as significant as the line of business might have feared. For Electricity Company A, primarily a new system is needed to handle the real-time values and some of the existing systems need to be updated. Additionally the combined extra work load might require extra personnel for Electricity Company A even though the individual work assignments are fairly small. The actions required should be fairly similar for companies of approximately equal size but might be more extensive for smaller non-transmission system connected electricity companies. All companies need, however, to conduct an individual analysis to determine which specific actions are required for them. The conclusions of this thesis aspired, and partly succeeded, to be generalizable on a European level. One example of this is the usage of the Intervention Strategy Model which proved applicable for determining which specific actions are required for all European electricity companies. Furthermore the concerns presented and the possible consequences of the increased information handling found, are generalizable but not complete for all European electricity companies. This thesis focused on one part of the complex Network Codes’ consequences and consequently further research is needed to fully understand the consequences for the electricity business in total.
|
98 |
Presence of potentially pathogenic heterotrophic plate count (HPC) bacteria occurring in a drinking water distribution system in the North-West Province, South Africa / by Leandra VenterVenter, Leandra January 2010 (has links)
There is currently growing concern about the presence of heterotrophic plate count (HPC)
bacteria in drinking water. These HPC may have potential pathogenic features, enabling
them to cause disease. It is especially alarming amongst individuals with a weakened
immune system. South Africa, the country with the highest incidents of HIV positive
individuals in the world, mainly uses these counts to assess the quality of drinking water in
terms of the number of micro-organisms present in the water. These micro-organisms may
be present in the bulk water or as biofilms adhered to the surfaces of a drinking water
distribution system. The current study investigated the pathogenic potential of HPC bacteria
occurring as biofilms within a drinking water distribution system and determined the
possible presence of these micro-organims within the bulk water. Biofilm samples were
taken from five sites within a drinking water distribution system. Fifty six bacterial colonies
were selected based on morphotypes and isolated for the screening of potential pathogenic
features. Haemolysin production was tested for using sheep-blood agar plates. Of the 56,
31 isolates were ?-haemolytic. Among the 31 ?-haemolytic positive isolates 87.1% were
positive for lecithinase, 41.9% for proteinase, 19.4% for chondroitinase, 9.7% for DNase
and 6.5% for hyaluronidase. All of the ?-haemolytic isolates were resistant to
oxytetracycline 30 ?g, trimethoprim 2.5 ?g and penicillin G10 units, 96.8% were resistant to
vancomycin 30 ?g and ampicillin 10 ?g, 93.5% to kanamycin 30 ?g, 74.2% to
chloramphenicol 30 ?g, 54.8% to ciprofloxacin 5 ?g, 22.6% to streptomycin 300 ?g and
16.1% to erythromycin 15 ?g. Nineteen isolates producing two or more enzymes were
subjected to Gram staining. The nineteen isolates were all Gram-positive. These isolates
were then identified using the BD BBL CRYSTALTM Gram-positive (GP) identification (ID)
system. Isolates were identified as Bacillus cereus, Bacillus licheniformis, Bacillus subtilis,
Bacillus megaterium, Bacillus pumilus and Kocuria rosea. 16S rRNA gene sequencing was
performed to confirm these results and to obtain identifications for the bacteria not identified
with the BD BBL CRYSTALTM GP ID system. Additionally identified bacteria included
Bacillus thuringiensis, Arthrobacter oxydans and Exiguobacterium acetylicum.
Morphological properties of the different species were studied with transmission electron
microscopy (TEM) to confirm sequencing results. All the isolates displayed rod shaped cells
with the exception of Arthrobacter oxydans being spherical in the stationary phase of their life cycle. Bulk water samples were taken at two sites in close proximity with the biofilm
sampling sites. The DNA was extracted directly from the water samples and the 16S rRNA
gene region was amplified. Denaturing gradient gel electrophoresis (DGGE) was performed
to confirm the presence of the isolates from the biofilm samples in the bulk water samples.
The presence of Bacillus pumilus and Arthrobacter oxydans could be confirmed with
DGGE. This study demonstrated the presence of potentially pathogenic HPC bacteria within
biofilms in a drinking water distribution system. It also confirmed the probable presence of
two of these biofilm based bacteria in the bulk water. / Thesis (M.Sc. (Microbiology))--North-West University, Potchefstroom Campus, 2010.
|
99 |
Presence of potentially pathogenic heterotrophic plate count (HPC) bacteria occurring in a drinking water distribution system in the North-West Province, South Africa / by Leandra VenterVenter, Leandra January 2010 (has links)
There is currently growing concern about the presence of heterotrophic plate count (HPC)
bacteria in drinking water. These HPC may have potential pathogenic features, enabling
them to cause disease. It is especially alarming amongst individuals with a weakened
immune system. South Africa, the country with the highest incidents of HIV positive
individuals in the world, mainly uses these counts to assess the quality of drinking water in
terms of the number of micro-organisms present in the water. These micro-organisms may
be present in the bulk water or as biofilms adhered to the surfaces of a drinking water
distribution system. The current study investigated the pathogenic potential of HPC bacteria
occurring as biofilms within a drinking water distribution system and determined the
possible presence of these micro-organims within the bulk water. Biofilm samples were
taken from five sites within a drinking water distribution system. Fifty six bacterial colonies
were selected based on morphotypes and isolated for the screening of potential pathogenic
features. Haemolysin production was tested for using sheep-blood agar plates. Of the 56,
31 isolates were ?-haemolytic. Among the 31 ?-haemolytic positive isolates 87.1% were
positive for lecithinase, 41.9% for proteinase, 19.4% for chondroitinase, 9.7% for DNase
and 6.5% for hyaluronidase. All of the ?-haemolytic isolates were resistant to
oxytetracycline 30 ?g, trimethoprim 2.5 ?g and penicillin G10 units, 96.8% were resistant to
vancomycin 30 ?g and ampicillin 10 ?g, 93.5% to kanamycin 30 ?g, 74.2% to
chloramphenicol 30 ?g, 54.8% to ciprofloxacin 5 ?g, 22.6% to streptomycin 300 ?g and
16.1% to erythromycin 15 ?g. Nineteen isolates producing two or more enzymes were
subjected to Gram staining. The nineteen isolates were all Gram-positive. These isolates
were then identified using the BD BBL CRYSTALTM Gram-positive (GP) identification (ID)
system. Isolates were identified as Bacillus cereus, Bacillus licheniformis, Bacillus subtilis,
Bacillus megaterium, Bacillus pumilus and Kocuria rosea. 16S rRNA gene sequencing was
performed to confirm these results and to obtain identifications for the bacteria not identified
with the BD BBL CRYSTALTM GP ID system. Additionally identified bacteria included
Bacillus thuringiensis, Arthrobacter oxydans and Exiguobacterium acetylicum.
Morphological properties of the different species were studied with transmission electron
microscopy (TEM) to confirm sequencing results. All the isolates displayed rod shaped cells
with the exception of Arthrobacter oxydans being spherical in the stationary phase of their life cycle. Bulk water samples were taken at two sites in close proximity with the biofilm
sampling sites. The DNA was extracted directly from the water samples and the 16S rRNA
gene region was amplified. Denaturing gradient gel electrophoresis (DGGE) was performed
to confirm the presence of the isolates from the biofilm samples in the bulk water samples.
The presence of Bacillus pumilus and Arthrobacter oxydans could be confirmed with
DGGE. This study demonstrated the presence of potentially pathogenic HPC bacteria within
biofilms in a drinking water distribution system. It also confirmed the probable presence of
two of these biofilm based bacteria in the bulk water. / Thesis (M.Sc. (Microbiology))--North-West University, Potchefstroom Campus, 2010.
|
100 |
A genetic algorithm for power distribution system planningRivas-Davalos, Francisco January 2004 (has links)
The planning of distribution systems consists in determining the optimum site and size of new substations and feeders in order to satisfy the future power demand with minimum investment and operational costs and an acceptable level of reliability. This problem is a combinatorial, non-linear and constrained optimization problem. Several solution methods based on genetic algorithms have been reported in the literature; however, some of these methods have been reported with applications to small systems while others have long solution time. In addition, the vast majority of the developed methods handle planning problems simplifying them as single-objective problems but, there are some planning aspects that can not be combined into a single scalar objective; therefore, they require to be treated separately. The cause of these shortcomings is the poor representation of the potential solutions and their genetic operators This thesis presents the design of a genetic algorithm using a direct representation technique and specialized genetic operators for power distribution system expansion planning problems. These operators effectively preserve and exploit critical configurations that contribute to the optimization of the objective function. The constraints of the problems are efficiently handle with new strategies. The genetic algorithm was tested on several theoretical and real large-scale power distribution systems. Problems of network reconfiguration for loss reduction were also included in order to show the potential of the algorithm to resolve operational problems. Both single-objective and multi-objective formulations were considered in the tests. The results were compared with results from other heuristic methods such as ant colony system algorithms, evolutionary programming, differential evolution and other genetic algorithms reported in the literature. From these comparisons it was concluded that the proposed genetic algorithm is suitable to resolve problems of largescale power distribution system planning. Moreover, the algorithm proved to be effective, efficient and robust with better performance than other previous methods.
|
Page generated in 0.1024 seconds