• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 334
  • 16
  • 9
  • 9
  • 9
  • 9
  • 6
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 359
  • 248
  • 94
  • 80
  • 69
  • 56
  • 54
  • 54
  • 51
  • 51
  • 50
  • 44
  • 43
  • 40
  • 38
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Influência da refrigeração na dureza de resinas compostas híbrida e microparticulada / Fernando Henrique Ruppel Osternack ; orientadora, Janaína Bertoncelo de Almeida

Osternack, Fernando Henrique Ruppel January 2006 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2006 / Inclui bibliografia / O objetivo do presente estudo in vitro, foi de avaliar a dureza Knoop das resinas compostas Charisma (C) e Durafill VS (D) quando polimerizadas: na temperatura do ambiente (A) (23+-1ºC); refrigerada (4+-1ºC), com tempo de espera de 15 minutos após a remoç
42

Avaliação in situ da influência da utilização de diferentes sistemas adesivos no desenvolvimento da cárie secundária em esmalte / In situ evaluation of secondary caries inhibition promoted by self-etch adhesive systems containing antibacterial agents

Vasconcelos, Suyane Maria Luna Cruz de January 2008 (has links)
VASCONCELOS, Suyane Maria Luna Cruz de. Avaliação in situ da influência da utilização de diferentes sistemas adesivos no desenvolvimento da cárie secundária em esmalte. 2008. 53 f. Dissertação (Mestrado em Odontologia) - Universidade Federal do Ceará. Faculdade de Farmácia, Odontologia e Enfermagem, Fortaleza, 2008. / Submitted by denise santos (denise.santos@ufc.br) on 2011-12-19T12:32:21Z No. of bitstreams: 1 2008_dis_smlcvasconcelos.pdf: 1627430 bytes, checksum: dc91483ce3821b1b638f3d470fcb3d52 (MD5) / Approved for entry into archive by Eliene Nascimento(elienegvn@hotmail.com) on 2012-02-02T16:12:23Z (GMT) No. of bitstreams: 1 2008_dis_smlcvasconcelos.pdf: 1627430 bytes, checksum: dc91483ce3821b1b638f3d470fcb3d52 (MD5) / Made available in DSpace on 2012-02-02T16:12:23Z (GMT). No. of bitstreams: 1 2008_dis_smlcvasconcelos.pdf: 1627430 bytes, checksum: dc91483ce3821b1b638f3d470fcb3d52 (MD5) Previous issue date: 2008 / Contemporary adhesives systems present satisfactory bonding to enamel and dentin. However, replacement of the restorations due to secondary caries formation is still a major problem and of great concern in Dentistry. Thus, this study assessed in situ the effects of adhesive systems containing or not fluoride and/or the antibacterial monomer 12-methacryloyloxydodecylpyridinium bromide (MDPB) on the microbiological composition of dental biofilm and on enamel demineralization. During two phases of 14 days each, ten volunteers wore palatal appliances containing four human enamel slabs, which were extra-orally restored using a resin composite (Z250 3M-ESPE) and one of the following adhesive systems: Adper™ Single Bond 2 (total etch, G1); All-Bond SE™ (self-etch, G2); One-Up Bond F Plus (self-etch containing fluoride G3) and Clearfil Protect Bond (self-etch containing fluoride and MDPB, G4). The volunteers were randomly allocated to treatments, and those who received G1 and G2 in the first phase received G3 and G4 in the second one, and vice versa. The volunteers were asked to drop a 20% sucrose solution onto the slabs eight times per day and to use fluoridated dentifrice 3 times per day. The biofilm formed on the slabs was analyzed with regard to total and mutans streptococci as well as lactobacilli counts. Demineralization was determined on enamel around the restorations by cross-sectional microhardness. The data were analyzed by analysis of variance, ANOVA. No differences were found for microbiological composition or enamel demineralization among the studied adhesive systems. It can be concluded that that fluoride or MDPB addition to adhesives systems presented no effect in controlling caries around resin restorations in this in situ model. / Os sistemas adesivos atuais apresentam resultados satisfatórios no que concerne à adesão ao esmalte e à dentina, entretanto, a maior causa de falhas em restaurações estéticas ainda é a ocorrência de recidiva de cárie ao longo de suas margens. Desta forma, este estudo avaliou a ação de sistemas adesivos com flúor e/ou com um novo monômero, brometo de metacriloiloxidodecilpiridinio (MDPB) na composição microbiológica do biofilme dental e no processo de desmineralização do esmalte adjacente à restauração de resina composta, mediante um delineamento in situ, cruzado e duplo-cego. Durante duas fases de 14 dias, dez voluntários utilizaram dispositivos palatinos, contendo, cada um, quatro blocos de esmalte dental humano, restaurados extra-oralmente com resina composta Z250 e um dos seguintes sistemas adesivos: Adper™ Single Bond 2 (condicionamento total, G1), All-Bond SE™ (autocondicionante, G2), One-Up Bond F Plus (autocondicionante com flúor, G3) e Clearfil Protect Bond (autocondicionante com flúor e MDPB, G4). Os voluntários foram aleatoriamente divididos entre os grupos, sendo que os que receberam os sistemas adesivos referentes aos grupos G1 e G2, na 1ª fase, receberam os tratamentos referentes aos grupos G3 e G4 na 2ª fase e vice-versa. Todos os voluntários foram instruídos a gotejar sobre os blocos, oito vezes por dia, uma solução de sacarose a 20%, simulando um desafio cariogênico, e a utilizar um dentifrício fluoretado padronizado três vezes por dia na higienização dentária. Após o término de cada fase o biofilme formado sobre cada bloco foi coletado e utilizado para a contagem de estreptococos totais, estreptococos mutans e lactobacilos. A perda de mineral foi analisada por meio do teste de microdureza em corte longitudinal do esmalte adjacente à restauração. Aplicou-se a análise de variância, ANOVA, não sendo observada diferença estatisticamente significante para a composição microbiológica ou desmineralização do esmalte entre os adesivos estudados. Concluiu-se que a incorporação de MDPB e/ou flúor nos sistemas adesivos autocondicionantes não foi capaz, nas condições deste estudo, de prevenir a ocorrência da cárie secundária.
43

Avaliação das propriedades mecânicas do aço DIN 27MnCrB5 para o processo de estampagem a quente

Bueno, Juliano de Sousa January 2017 (has links)
Este trabalho avalia as propriedades mecânicas, microestrutura resultante e força de estampagem da liga DIN 27MnCrB5 para o processo de estampagem a quente nas temperaturas de aquecimento de 750°C, 850°C e 950°C. Para isso foram realizados ensaios nas três temperaturas e medidos os valores da força necessária para a estampagem da chapa, que foi aplicada em uma área de 30mm x 1,50mm. A partir da peça estampada foram realizadas análises metalográficas da microestrutura resultante e medições de dureza para a correlação com as propriedades mecânicas. Para as temperaturas de aquecimento de 750°C e 850°C não foi verificada microestrutura martensítica nas peças estampadas. Para o ensaio realizado com uma temperatura de aquecimento de 950°C ocorreu transformação martensítica na peça na região que esteve em contato com o prensa chapa e a matriz. Esta transformação metalúrgica resultou em valores de dureza de 715±17HV0,2 em comparação com a condição inicial da chapa, cuja dureza era de 187±5HV0,2. As medições de força de estampagem para as três temperaturas de ensaio indicam uma redução da força com o aumento da temperatura de aquecimento da chapa. Para a temperatura de aquecimento da chapa de 750°C o valor médio da força de estampagem foi de 14kN, para a temperatura de 850°C o valor médio da força de estampagem foi de 9kN, enquanto para a temperatura de 950°C foi encontrado o valor médio de 5kN. / This work evaluates the mechanical properties, resulting microstructure and stamping force of the DIN 27MnCrB5 alloy for the hot stamping process at the heating temperatures of 750°C, 850°C and 950°C. For this, tests were carried out at the three temperatures and the values of the force required for the stamping of the sheet were measured, which was applied in an area of 30mm x 1,50mm. From the stamped part metallographic analyzes of the resulting microstructure and hardness measurements were performed for the correlation with the mechanical properties. For the heating temperatures of 750°C and 850°C, no martensitic microstructure was observed in the stamped parts. For the test performed with a heating temperature of 950°C martensitic transformation occurred in the part in the region that was in contact with the blank holder and the die. This metallurgical transformation resulted in hardness values of 715±17HV0,2 compared to the initial condition of the sheet, whose hardness was 187±5HV0,2. Stamping force measurements for the three test temperatures indicate a reduction in force with the increase of the sheet heating temperature. For the sheet heating temperature of 750°C the average value of the stamping force was 14kN, at the temperature of 850°C the average value of the stamping force was 9kN, while at the temperature of 950°C it was found The average value of 5kN.
44

Desenvolvimento de compósitos cerâmicos laminares à base de alumina e zircônia

Camerini, Rafael Vieira January 2013 (has links)
Neste trabalho foram estudadas estruturas cerâmicas laminares formadas por lamelas de alumina de alta pureza e lamelas do compósito alumina/zircônia parcialmente estabilizada. Estas estruturas foram conformadas por colagem de barbotina sequencial. Nas lamelas constituídas pelo compósito alumina/zircônia foi investigado o efeito do teor de zircônia parcialmente estabilizada nas propriedades do compósito laminar. Depois de dominada a técnica de produção dos compósitos, as propriedades mecânicas destas cerâmicas foram caracterizadas e otimizadas. Foi verificada a influência da espessura relativa entre as camadas no campo de tensões residuais formado. Um estudo sistemático foi desenvolvido para relacionar as propriedades mecânicas dos compósitos laminares com mecanismos microscópicos existentes neste tipo de cerâmicas. Neste estudo foram realizados testes instrumentados de dureza, ensaios de flexão, medidas de fluorescência de rubi para avaliação do nível de tensionamento interno, ensaios de dureza, análises por microscopia eletrônica de varredura e microscopia óptica, e simulações computacionais por elementos finitos. Os resultados mostraram que, além da influência da espessura relativa entre as lâminas, há uma forte influência da razão de aspecto (RA=L/d, onde L é a largura da lâmina e d seu comprimento). / In this study, laminar ceramic structures formed by layers of high purity alumina and alumina/partially stabilized zirconia composite layers were investigated. These structures were formed by sequential slip casting. In the alumina/zirconia layers it was investigated the effect of partially stabilized zirconia content on the composite properties. After mastering the experimental technique to produce the laminar ceramic composites, their mechanical properties were characterized and optimized. The influence of the thickness of adjacent layers on the residual stress fields formed was investigated. A systematic study was settled to correlate the mechanical properties of laminar composites with microscopic mechanisms peculiar of this type of ceramics. The samples were characterized by hardness instrumented tests (HIT), bending tests, fluorescence measurements, hardness tests, scanning electron microscopy and optical microscopy, and computational simulations using finite elements. The results showed that, besides the influence of the relative thickness between the layers there was a strong influence of the aspect ratio (AR = W / d, where W is the width of the layer and d its length).
45

Caracterização do aço inoxidável ASTM A743 CA6NM e do seu revestimento de WC-10Co-4Cr aspergido termicamente por HVOF / Microstructural caracterization of the ASTM A743 CA6NM stainless steel and of its WC-10Co-4Cr coating termal sprayed by HVOF

Martins, André Fernandes [UNESP] 24 July 2015 (has links) (PDF)
Made available in DSpace on 2015-09-17T15:26:52Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-07-24. Added 1 bitstream(s) on 2015-09-17T15:45:05Z : No. of bitstreams: 1 000848150.pdf: 3354725 bytes, checksum: 371283898c5fbe9d517f74b0b02f5980 (MD5) / A tecnologia de aplicação de revestimento por aspersão térmica de chama oxicombustível de alta velocidade, mais conhecida pelo seu termo em inglês HVOF (high velocity oxigen fuel), apresenta o melhor custo benefício entre as técnicas de aspersão térmica, além de permitir uma ampla gama de revestimentos possíveis de serem aspergidos. Por essas razões, esse é o processo mais utilizado no recobrimento de pás de turbinas fabricadas para usinas hidrelétricas, como é o caso das do projeto Santo Antônio localizado no Rio Madeira em Rondônia/Brasil. Este trabalho buscou caracterizar o aço inoxidável martensítico ASTM A743 CA6NM, assim como o revestimento de WC-10Co-4Cr durante as etapas do processo de aspersão térmica por HVOF. Foram feitas medidas de rugosidade, coeficiente de atrito, dureza, molhabilidade, porosidade e espessura de camada do revestimento, além da analise da microestrutura do aço inoxidável. Estas caracterizações foram feitas sobre o substrato usinado, jateado e sobre os revestimentos aspergidos, com espessura de 0,1 e 0,2 mm. Os resultados obtidos apresentam alteração significativa de dureza, com o valor médio elevando de 318 HV, no aço inox, para 1100 HV no revestimento. O coeficiente de atrito inicial foi de 0,2, passando para 0,4 em menos de 500 voltas no aço e 0,8 no revestimento. O caráter hidrofílico foi mantido na superfície do aço e no revestimento. O revestimento apresentou porosidade abaixo de 2% e a rugosidade Ra, em torno, de 4,6 Qm / The high velocity oxygen fuel (HVOF) coating technology, have shown the best results comparing with the related cost and it is able to be spray several coating composition. Due to all these reasons, this is the most used coating process on hydro power plants blades, as it is the case of Santo Antonio project settled in the Madeira river, Rondônia/Brazil. In This research was carried out the martensitic stainless steel characterization ASTM A743 CA6NM, as well as the characterization of the WC-10Co-4Cr coating during the HVOF process. Measurements of roughness, coefficient of friction, hardness, wettability, porosity, coating thickness and microstructure of base metal and coating, by optical microscope, were carried out. These analysis was done on machined stainless steel surface, on blasted surface and on 0,1 and 0,2 mm coating surfaces. The results demonstrate an increase in hardness from 318HV in the stainless steel to 1100HV in the coating. The initial coefficient of friction was 0,2 and raised up to 0,4 after 500 laps on the stainless steel and 0,8 on the coating. The hydrophilic behavior was kept on stainless steel and coating. The coating porosity was below 2% and the Ra roughness around 4,6 Qm
46

Desenvolvimento de um durômetro portátil para madeiras com o uso de transdutor de deslocamento / Development of a portable hardness tester for wood using displacement transducer

Assis, Albert Augusto de [UNESP] 25 June 2015 (has links) (PDF)
Made available in DSpace on 2015-12-10T14:22:44Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-06-25. Added 1 bitstream(s) on 2015-12-10T14:28:56Z : No. of bitstreams: 1 000851979.pdf: 2424291 bytes, checksum: 14042b0cfb79b396eacc0a592e69fb49 (MD5) / dureza é considerada um importante indicador de qualidade da madeira, pois, além de ser um teste de fácil aplicação, também apresenta boa correlação com outras propriedades importantes do material, como a densidade, compressão paralela e normal às fibras. O ensaio de dureza Janka tem sido amplamente utilizado na América do Sul e do Norte, enquanto que o ensaio de dureza Brinell tem tido predominância na Europa. Mais recentemente, estudos internacionais têm relatado a utilização da dureza dinâmica para a madeira, apresentando como principal vantagem a viabilização de ensaios em condições de campo. Este trabalho apresenta os resultados do desenvolvimento da terceira geração de um durômetro portátil para madeiras, que utiliza transdutor de deslocamento e processador eletrônico embarcado a fim de automatizar as medições de dureza dinâmica. Os ensaios funcionais do equipamento, realizados em oito espécies de eucalipto, revelaram forte correlação com a dureza Janka a possibilidade de sua estimativa por meio da dureza dinâmica. Além disso, os problemas clássicos de recuperação da área endentada e sinkingin foram contornados, pois o equipamento mediu a profundidade de endentação sob carga. Adicionalmente este trabalho propõe uma nova metodologia para cálculo da dureza dinâmica baseada na razão entre a força média resultante do impulso e a profundidade da endentação. / Hardness is considered a meaningful quality indicator for wood and correlates well with other mechanical properties of the material, like compressive strengths normal and perpendicular to the grain. Besides its good correlation to those mechanical properties, the hardness test is easier to perform than any other strength test. In Europe the most widely used method for determining wood hardness is the Brinell test, whereas in the Americas the Janka test is predominant. More recently, international studies have reported the use of dynamic hardness for wood, claiming as main advantage the feasibility of tests under field conditions. This paper presents results obtained in the development of the third generation of a portable hardness tester for wood, which uses displacement transducer and embedded electronic processor in order to automate the dynamic hardness measurement. Functional tests of the equipment carried out using eight species of Eucalyptus, revealed strong correlation to Janka hardness and the possibility of its prediction by dynamic hardness. Beyond that, the classical problems of sinking-in and recovery of the indented area where solved by the equipment using under-load measurements of indentation's depth. Furthermore, this paper introduces a new methodology for dynamic hardness calculation, which is based on the ratio between the average impulse force promoted by the indentation and its depth.
47

Microdureza superficial do cimento resinoso de ativado por duas diferentes fontes de luz com interposição de cerômero e porcelana

Alencar Júnior, Emmanuel Arraes de [UNESP] January 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2005Bitstream added on 2014-06-13T18:42:03Z : No. of bitstreams: 1 alencarjunior_ea_dr_arafo.pdf: 544864 bytes, checksum: 9e132bf130badf4c90a40a1d5fbc0aee (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Nessa pesquisa utilizou-se de três unidades fotoativardoras na polimerização de uma marca comercial de cimento resinoso de dupla ativação, com a interposição de uma lâmina de cerômero e de porcelana, para avaliar a microdureza superficial do cimento resinoso, considerando sua superfície do topo e da base Os corpos-de-prova foram confeccionados utilizando-se matrizes metálicas com 2mm de espessura e 16mm de diâmetro, com o orifício central medindo 8mm de diâmetro (figura 4), coincidindo com o diâmetro da ponta dos aparelhos de luz. Como espaçadores foram utilizados anéis metálicos com 2mm e 4mm de altura confeccionados de cerâmica e cerômero, na tentativa de se reproduzir as espessuras médias das restaurações indiretas realizadas clinicamente. Foram realizados quatro corpos-de-prova para cada grupo, com os três aparelhos fotoativadores e para cada grupo do material intermediário. A inserção da resina no orifício central da matriz foi realizada em uma única porção, utilizando-se de uma seringa Centrix. Após a inserção do cimento, obteve-se um pequeno excesso do material. Sobre o cimento a foi colocada uma tira de poliéster e posicionado peso de um quilo para a homogeneização e planificação da superfície. Após a remoção do peso, foi executada a ativação do cimento resinoso com a ponta dos aparelhos de luz utilizados no experimento, posicionado diretamente sobre as pastilhas de cerâmica e cerômero. Os corpos-de-prova foram removidos da matriz metálica, acondicionados em recipientes à prova de luz e mantidos a temperatura de 37o C durante 24 horas. As superfícies do topo e da base do corpo-de-prova foram polidas com lixas d'água em graus descendentes (800, 320 e 600 norton) de abrasividade e submetidas ao teste de microdureza. Para a determinação da microdureza, foi utilizado o aparelho Microdurômetro Digital MHT-110 MICROHARDNESS TESTER, Anton... . / The aim of this study was to evaluated the efficiency of three different units of light curing in activating a commercial trend of resin cement. The body-of-test had been confectioned using first metallic with 2mm of thickness and 16mm of diameter, with the central orifice measuring 8mm of diameter (figure 4), coinciding with the diameter of the tip of the light devices. As spacers metallic rings with 2mm and 4mm of height confectioned of ceramics had been used and cerômero, in the attempt of if clinically reproducing the average thicknesses of the carried through indirect restorations. They had been carried through four body-of-test for each group, with the three devices photo curing and for each group of the intermediate material. The insertion of the resin in the central orifice of the matrix was carried through in an only portion, using itself of a Centrix syringe. After the insertion of the cement, got a small excess of the material. On the cement a polyester strap was placed it and located weight of one kilo for the homogenization and planning of the surface. After the removal of the weight, was executed the activation of the resin cement with the tip of the devices of light used in the experiment, located directly on the tablets of ceramics and ceromer. The test bodies had been gotten thus the body-of-test had been removed of the metallic matrix, conditioned in containers to the test of light and kept the temperature of 37o C during 24 hours. The surfaces of the top and the base of the body-of-test had been polishing with sandpapers in degrees descending (800, 320 and 600 norton) of abrasiveness and submitted to the micro hardness test. For the determination of the micro hardness, the device Digital Micro hardness tester MHT-110 MICROHARDNESS TESTER, Anton Paar-Paar Physica, Graz was used, Austria, of the Institute of Chemistry of Araraquara (UNESP) with load of 50N during 30 seconds... (Complete abstract, click electronic address below)
48

Avaliação de um aparelho de luz halógena e um dispositivo Leds na técnica de fotoativação trans-dental: estudo da profundidade de polimerização pelos testes de dureza e espectroscopia de fluorescência

Rastelli, Alessandra Nara de Souza [UNESP] 09 November 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-11-09Bitstream added on 2014-06-13T19:20:25Z : No. of bitstreams: 1 rastelli_ans_dr_arafo.pdf: 1588793 bytes, checksum: f1face4ce729ada146c1f40f26e0748f (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo desse trabalho foi avaliar a capacidade de polimerização de uma fonte de luz halógena e um dispositivo LEDs utilizados na técnica de fotoativação trans-dental. Para isto, foram confeccionadas amostras em uma matriz metálica circular contendo um orifício central com 4 mm de diâmetro e 2 mm de profundidade (ISO 4049) utilizando-se a resina composta microhíbrida Filtek Z-250 (3M/ESPE), na cor A2. Cinco amostras foram confeccionadas para cada situação diferente, distribuídas em grupos da seguinte maneira: GRUPO I - aparelho Curing Light e dispositivo LEDs utilizados pelos tempos de exposição de 40 e 60 segundos, para as espessuras de 0 (grupo controle); 1,0 mm; 2,0 mm e 3,0 mm de faceta de estrutura dental, nas mesmas condições de operação armazenados em meio seco por 24 horas, avaliados pelo teste de dureza Vickers (VHN); GRUPO II - aparelho Curing Light e dispositivo LEDs utilizados pelos tempos de exposição de 40 e 60 segundos, para as espessuras de 0 (grupo controle); 1,0 mm; 2,0 mm e 3,0 mm de faceta de estrutura dental nas condições originais de operação armazenados em meio seco por 24 horas e 30 dias, água destilada, saliva artificial e ácido acético a 10% por 30 dias, avaliados pelo teste de dureza Vickers (VHN) e GRUPO III - aparelho Curing Light e dispositivo LEDs utilizados pelos tempos de exposição de 40 e 60 segundos, para as espessuras de 0 (grupo controle); 1,0 mm; 2,0 mm e 3,0 mm de faceta de estrutura dental armazenados em rodamina 6G durante 24 horas sendo avaliados pelo teste de espectroscopia de fluorescência. Os dados foram submetidos à Análise Estatística de Variância (p<0,05) e complementadas por comparações múltiplas pelo teste de Newman-Keuls ao nível de 5% de significância. Baseados nos resultados encontrados, pudemos concluir que: 1) a fonte de luz halógena testada proporcionou... . / The objective of this study was evaluate the light-curing capacity, throught dental structure, of two differents light-curing device (Halogen and LEDs), by hardness and fluorescent spectroscopic testings. The samples were made in a circular metallic mold with a orifice in the central portion measuring 4 mm in diameter and 2 mm in thickness (ISO 4049). The composite resin was used the Filtek Z-250 (3M/ESPE) at collor A2. Five samples were made by situation analyzed: GROUP I - halogen and LEDs light-curing devices by exposure times of 40 and 60 seconds for the thickness 0 (control group); 1,0 mm; 2,0 mm and 3,0 mm of the structure dental facet, at the same operation parameters stored in dry mean for 24 hours; GROUP II - halogen and LEDs light-curing devices by exposure times of 40 and 60 seconds for the thickness 0 (control group); 1,0 mm; 2,0 mm and 3,0 mm of the structure dental facet, at the original operation parameters stored in dry mean for 24 hours and thirty days, distilled water, artificial saliva and acetic acid at 10% for thirty days and GROUP III - halogen and LEDs light-curing devices by exposure times of 40 and 60 seconds for the thickness 0 (control group); 1,0 mm; 2,0 mm and 3,0 mm of the structure dental facet stored in 6G rodhamine evaluated for fluorescent spectroscopic testing. The data were submitted to the Statistical Analysis of Variance (p <0,05) and complemented by multiple comparisons by the test of Newman-Keuls at the level 5% of significance. Based on the found results, we could end that: 1) the device of tested halogen light provided larger curing of depth for the trans-dental technique; 2) the device LEDs promoted larger curing of depth for the trans-dental technique, when the source of halogen light was used in the same operation parameters; 3) in the technique trans-dental, independent of the source of used... (Complete abstract, click electronic address below).
49

O uso da termociclagem na avaliação da absorção, solubilidade, dureza e alteração de cor de reembasadores resilientes

Mancuso, Daniela Nardi [UNESP] 19 December 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-12-19Bitstream added on 2014-06-13T20:25:52Z : No. of bitstreams: 1 mancuso_dn_dr_araca.pdf: 1122957 bytes, checksum: f6980a1d234a3c5f607d0c22249241c6 (MD5) / Este estudo teve como objetivo avaliar a absorção, solubilidade, dureza e alteração de cor de reembasadores resilientes após termociclagem. Foram utilizados 4 materiais reembasadores resilientes, sendo 1 à base de resina (Trusoft) e 3 à base de silicone (Dentusil, Ufi Gel P e Ufi Gel SC). Foram confeccionadas 80 amostras no total, sendo que metade delas foi submetida ao teste de absorção e solubilidade e a outra metade, aos testes de dureza Shore A e alteração de cor. Todas as amostras foram submetidas à 2000 ciclos de termociclagem. O Dentusil apresentou os seguintes valores: Shore A (40,50); ΔE (0,83); absorção (0,30); solubilidade (0,01). Já o Trusoft apresentou os seguintes valores: Shore A (18,50); ΔE (3,92); absorção (1,48); solubilidade (1,26). O UfiGel P e SC apresentaram resultados semelhantes e intermediarios para os 3 testes. Portanto conclui-se que todas as propriedades estão intimamente relacionadas e que quanto maior for a dureza inicial do material, menor será a absorção e solubilidade e consequentemente menor será a alteração de cor. / The purpose of this study was to investigate absorption, solubility, hardness and colour change of 4 soft liners after thermocycling. A resin base (Trusoft) and three silicone base (Dentusil, Ufi Gel P e Ufi Gel SC) were used on this research. A total of eighty samples were manufactured: forty for absorption and solubility test and forty for both hardness and colour change tests. All samples were subjected to 2000 hours of thermocycling. Dentusil showed the following values: Shore A hardness (40.50), colour change (ΔE=0.83), absorption (0.30) and solubility (0.01). Trusoft, on the other hand, showed the following values: Shore A hardness (18.50), colour change (ΔE=3.92), absorption (1.48) and solubility (1.26). Both UfiGel P and SC showed similar results for all three tests. All properties are linked and as big is the initial hardness, small will be both absorption and solubility and consequently small will be the colour change.
50

Caracterização microestrutural e mecânica de trilhos ferroviários soldados de topo por caldeamento

Briguente, Claudemir Aparecido [UNESP] 15 June 2013 (has links) (PDF)
Made available in DSpace on 2014-12-02T11:16:53Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-06-15Bitstream added on 2014-12-02T11:21:14Z : No. of bitstreams: 1 000795872.pdf: 2547513 bytes, checksum: fff32045103b6f32d6a6e4db5e46f8b8 (MD5) / É sabido que o processo de soldagem devido ao aporte de calor interfere na estrutura e comportamento mecânico do material, fator que deve ser estudado para melhor compreender as características mecânicas e microestruturais dessas juntas soldadas e comparar essas mudanças com o metal base para melhor compreender os resultados. O estudo deste trabalho foi pesquisar e discutir os resultados das mudanças microestruturais e mecânicas ocorridas nos trilhos soldados por caldeamento (HF-ERW, High Frequency Electric Resistance Welding). O processo de soldagem por caldeamento, apesar de sua facilidade de execução exige um rígido controle dos parâmetros envolvidos, entre eles, preparação e alinhamento das peças, preaquecimento, controle na aplicação da corrente elétrica para monitoramento da temperatura o controle de resfriamento pós-solda. Qualquer desvio nestas variáveis pode acarretar defeitos, tais como: crescimento de grão, dureza excessiva na região soldada, vazios, entre outros que, aliados às condições severas de carregamento impostos ao trilho, devido à passagem dos trens, ocasionam a nucleação e surgimento de pequenas trincas comprometendo estruturalmente o trilho. Para comprovação dos estudos da caracterização microestrutural e mecânica dos trilhos soldados por HF-ERW foram realizados os ensaios de análise dos componentes químicos do material, de ultrassom, de flexão em três pontos, de micro e macrodureza, de metalografia, de tração, e de impacto. Os ensaios realizados nos fornecem dados suficientes para determinação do comportamento do material, onde os estudos foram concentrados na região da junta soldada focando os componentes do trilho (Boleto, Alma e Patim), e nesses componentes as regiões classificadas como Metal Base (MB), Zona Afetada Termicamente (ZAT) e Linha de Caldeamento (LC). Com os resultados obtidos foi possível concluir que a junta soldada sofreu mudanças tanto microestrutural, como no ... / It is known that the process of welding heat input due to interfere with the structure and mechanical behavior of the material factor that should be studied to better understand the mechanical and microstructural characteristics of these soldered joints and to compare these with the base metal changes to better understand the results. The study of this work was to investigate and discuss the results of microstructural and mechanical changes occurring in the cladding rails welded (ERW-HF, High Frequency Electric Resistance Welding). The welding process, despite its ease of implementation requires strict control of the parameters involved, including, preparation and alignment of parts, preheat control the application of electrical current for monitoring temperature control cooling after solder. Any deviation in these variables can cause defects such as grain growth, excessive hardness in the welded region, voids, among others, coupled with the severe conditions of loading imposed on the rail, to the passage of trains, cause the nucleation and the appearance of small compromising structurally broken rail. To prove the studies of microstructural characterization and mechanical rails welded ERW-HF assays were performed to analyze the chemical components of the material, ultrasound, three-point bending, micro and macro-hardness, metallography, tensile, and impact. The tests provide us with sufficient data to determine the behavior of the material, where the studies were concentrated in the region of the weld components focusing rail (head, web and foot), and these components regions classified as Base Metal (BM) Thermally Affected Zone (HAZ) and Line of Fusing (LF). With these results we conclude that the welded joint has suffered both micro structural changes, such as the mechanical behavior of the material in relation to the base metal, with cementite precipitated at grain boundaries in the LC, the less elastic deformation in the HAZ, and ...

Page generated in 0.0417 seconds