• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • 7
  • 4
  • 3
  • 2
  • 2
  • Tagged with
  • 26
  • 7
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Energieeintrag langsamer hochgeladener Ionen in Festkörperoberflächen / Energy dissipation of highly charged ions interacting with solid surfaces

Kost, Daniel 11 October 2007 (has links) (PDF)
Motiviert durch die in der Literatur bisher unvollständige Beschreibung der Relaxation hochgeladener Ionen vor Festkörperoberflächen, besonders in Bezug auf den Eintrag potenzieller Energie in Oberflächen und der Aufstellung einer vollständigen Energiebilanz, werden in dieser Arbeit komplementäre Studien präsentiert, die sowohl die Ermittlung des Anteils der deponierten potenziellen Energie als auch die Ermittlung der emittierten potenziellen Energie ermöglichen. Zum Einen wird zur Bestimmung des eingetragenen Anteils der potenziellen Energie eine kalorimetrische Messanordnung verwendet, zum Anderen gelingt die Bestimmung der emittierten potenziellen Energie mittels doppeldifferenzieller Elektronenspektroskopie. Für vertiefende Studien werden Materialien unterschiedlicher elektronischer Strukturen (Cu, n-Si, p-Si und SiO2 ) verwendet. Im Falle der Kalorimetrie wird festgestellt, dass die eingetragene potenzielle Energie linear mit der inneren potenziellen Energie der Ionen wächst. Dabei bleibt das Verhältnis zwischen der eingetragenen potenziellen Energie und der inneren potenziellen Energie nahezu konstant bei etwa (80 ± 10) %. Der Vergleich von Cu, n-Si und p-Si zeigt im Rahmen der Messfehler keine signifikanten Unterschiede in diesem Verhältnis. Es liegen jedoch deutlich unter jenem von SiO2. Die Elektronenspektroskopie liefert ein dazu komplementäres Ergebnis. Für Cu und Si konnte ebenfalls eine lineare Abhängigkeit zwischen emittierter Energie und innerer potenzieller Energie festgestellt werden. Das Verhältnis wurde hierfür bis zum Ladungszustand bis Ar7+ zu etwa (10 ± 5) % unabhängig vom Ladungszustand bestimmt. Im Gegensatz dazu liefert SiO2 eine nahezu verschwindende Elektronenausbeute. Für Ar8+ und Ar9+ steigt die Elektronenausbeute wegen der Beiträge der LMM-Augerelektronen für alle untersuchten Materialien leicht an. Der Anteil der emittierten Energie eines Ar9+ -Ions wird für Cu und Si zu etwa 20 % und für SiO2 zu etwa 10 % angegeben. Diese Ergebnisse sind in guter Übereinstimmung mit den Kalorimetrieexperimenten und erfüllen die Energiebilanz. Zusätzlich werden die experimentellen Ergebnisse mit einer Computersimulation modelliert, welche auf dem erweiterten dynamischen klassischen Barrierenmodell basiert. Aus diesen Rechnungen kann zudem jener Anteil der deponierten potenziellen Energie erhalten werden, welcher durch Bildladungsbeschleunigung vor der Oberfläche in kinetische Energie umgewandelt wurde. / Motivated by the incomplete scientific description of the relaxation of highly charged ions in front of solid surfaces and their energy balance, this thesis describes an advanced complementary study of determining deposited fractions and re-emitted fractions of the potential energy of highly charged ions. On one side, a calorimetric measurement setup is used to determine the retained potential energy and on the other side, energy resolved electron spectroscopy is used for measuring the re-emitted energy due to secondary electron emission. In order to study the mechanism of energy retention in detail, materials with different electronic structures are investigated: Cu, n-Si, p-Si and SiO2 . In the case of calorimetry, a linear relationship between the deposited potential energy and the inner potential energy of the ions was determined. The total potential energy which stays in the solid remains almost constant at about (80 ± 10) %. Comparing the results of the Cu, n-Si and p-Si targets, no significant difference could be shown. Therefore we conclude that the difference in energy deposition between copper, n-doped Si and p-doped Si is below 10 %, which is significantly lower than using SiO2 targets. For this purpose, electron spectroscopy provides a complementary result. For Cu and Si surfaces, an almost linear increase of the re-emitted energy with increasing potential energy of the ion up to Ar7+ was also observed. The ratio of the re-emitted energy is about (10 ± 5) % of the total potential energy of the incoming ion, almost independent of the ion charge state. In contrast, an almost vanishing electron emission was observed for SiO2 and for charge states below q=7. For Ar8+ and Ar9+, the electron emission increased due to the contribution of the projectile LMM Auger electrons and the re-emitted energy amounts up to 20 % for Cu and Si and around 10 % for SiO2 .These results are in good agreement with the calorimetric values. In addition, the experimental results are compared with computer simulations based on the extended dynamical over-the-barrier model. From these calculations, the ratio of deposited potential energy that is transformed into kinetic energy before deposition due to the image charge acceleration can be maintained.
22

Energieeintrag langsamer hochgeladener Ionen in Festkörperoberflächen

Kost, Daniel 26 April 2007 (has links)
Motiviert durch die in der Literatur bisher unvollständige Beschreibung der Relaxation hochgeladener Ionen vor Festkörperoberflächen, besonders in Bezug auf den Eintrag potenzieller Energie in Oberflächen und der Aufstellung einer vollständigen Energiebilanz, werden in dieser Arbeit komplementäre Studien präsentiert, die sowohl die Ermittlung des Anteils der deponierten potenziellen Energie als auch die Ermittlung der emittierten potenziellen Energie ermöglichen. Zum Einen wird zur Bestimmung des eingetragenen Anteils der potenziellen Energie eine kalorimetrische Messanordnung verwendet, zum Anderen gelingt die Bestimmung der emittierten potenziellen Energie mittels doppeldifferenzieller Elektronenspektroskopie. Für vertiefende Studien werden Materialien unterschiedlicher elektronischer Strukturen (Cu, n-Si, p-Si und SiO2 ) verwendet. Im Falle der Kalorimetrie wird festgestellt, dass die eingetragene potenzielle Energie linear mit der inneren potenziellen Energie der Ionen wächst. Dabei bleibt das Verhältnis zwischen der eingetragenen potenziellen Energie und der inneren potenziellen Energie nahezu konstant bei etwa (80 ± 10) %. Der Vergleich von Cu, n-Si und p-Si zeigt im Rahmen der Messfehler keine signifikanten Unterschiede in diesem Verhältnis. Es liegen jedoch deutlich unter jenem von SiO2. Die Elektronenspektroskopie liefert ein dazu komplementäres Ergebnis. Für Cu und Si konnte ebenfalls eine lineare Abhängigkeit zwischen emittierter Energie und innerer potenzieller Energie festgestellt werden. Das Verhältnis wurde hierfür bis zum Ladungszustand bis Ar7+ zu etwa (10 ± 5) % unabhängig vom Ladungszustand bestimmt. Im Gegensatz dazu liefert SiO2 eine nahezu verschwindende Elektronenausbeute. Für Ar8+ und Ar9+ steigt die Elektronenausbeute wegen der Beiträge der LMM-Augerelektronen für alle untersuchten Materialien leicht an. Der Anteil der emittierten Energie eines Ar9+ -Ions wird für Cu und Si zu etwa 20 % und für SiO2 zu etwa 10 % angegeben. Diese Ergebnisse sind in guter Übereinstimmung mit den Kalorimetrieexperimenten und erfüllen die Energiebilanz. Zusätzlich werden die experimentellen Ergebnisse mit einer Computersimulation modelliert, welche auf dem erweiterten dynamischen klassischen Barrierenmodell basiert. Aus diesen Rechnungen kann zudem jener Anteil der deponierten potenziellen Energie erhalten werden, welcher durch Bildladungsbeschleunigung vor der Oberfläche in kinetische Energie umgewandelt wurde. / Motivated by the incomplete scientific description of the relaxation of highly charged ions in front of solid surfaces and their energy balance, this thesis describes an advanced complementary study of determining deposited fractions and re-emitted fractions of the potential energy of highly charged ions. On one side, a calorimetric measurement setup is used to determine the retained potential energy and on the other side, energy resolved electron spectroscopy is used for measuring the re-emitted energy due to secondary electron emission. In order to study the mechanism of energy retention in detail, materials with different electronic structures are investigated: Cu, n-Si, p-Si and SiO2 . In the case of calorimetry, a linear relationship between the deposited potential energy and the inner potential energy of the ions was determined. The total potential energy which stays in the solid remains almost constant at about (80 ± 10) %. Comparing the results of the Cu, n-Si and p-Si targets, no significant difference could be shown. Therefore we conclude that the difference in energy deposition between copper, n-doped Si and p-doped Si is below 10 %, which is significantly lower than using SiO2 targets. For this purpose, electron spectroscopy provides a complementary result. For Cu and Si surfaces, an almost linear increase of the re-emitted energy with increasing potential energy of the ion up to Ar7+ was also observed. The ratio of the re-emitted energy is about (10 ± 5) % of the total potential energy of the incoming ion, almost independent of the ion charge state. In contrast, an almost vanishing electron emission was observed for SiO2 and for charge states below q=7. For Ar8+ and Ar9+, the electron emission increased due to the contribution of the projectile LMM Auger electrons and the re-emitted energy amounts up to 20 % for Cu and Si and around 10 % for SiO2 .These results are in good agreement with the calorimetric values. In addition, the experimental results are compared with computer simulations based on the extended dynamical over-the-barrier model. From these calculations, the ratio of deposited potential energy that is transformed into kinetic energy before deposition due to the image charge acceleration can be maintained.
23

Untersuchung der Erzeugung hochgeladener Ionen in einer Raumtemperatur-Elektronenstrahl-Ionenfalle

Ullmann, Falk 31 December 2005 (has links)
Hochgeladene Ionen stellen einen extremen Zustand der Materie dar, wie sie vornehmlich in kosmischen Plasmen zu finden ist. Die labormäßige Erzeugung und (spektroskopische) Untersuchung hochgeladener Ionen liefert wichtige Daten und Erkenntnisse für die Astrophysik und Fusionsforschung. Aufgrund ihrer zum Teil exotischen Eigenschaften besitzen hochgeladene Ionen ein großes Potential für eine Vielzahl neuer Anwendungen. Die bisher weltweit einzige Elektronenstrahl-Ionenfalle, die hochgeladene Ionen bis hin zu vollständig ionisierten Ionen unter Raumtemperaturbedingungen erzeugen und bereitstellen kann, die Dresden EBIT, ist Gegenstand der vorgelegten Arbeit. Die Dresden EBIT zeichnet sich neben ihrer Kompaktheit und einer einfachen Bedienung durch ihre Langzeitstabilität aus. Sowohl über Röntgenspektren als auch über die Extraktion der Ionen aus der EBIT konnte für eine Reihe von Elementen der Nachweis der Erzeugung von vollständig ionisierten Ionen bis Z=28 erbracht werden. Für schwere Elemente können Ionenladungszustände bis hin zu neonähnlichen Ionen erzeugt werden. Entscheidenden Einfluss auf den erzielten mittleren Ladungszustand hat die Ioneneinschlusszeit. Die zeitliche Entwicklung der Ladungszustandsverteilung, wie sie im Zusammenspiel der verschiedenen atomaren Prozesse simuliert werden kann, ist sowohl an einer Reihe von röntgenspektroskopischen Messungen als auch anhand von Extraktionsspektren untersucht worden. Neben der Beladung der EBIT mit gasförmigen Elementen ist insbesondere die Beladung mit Metallen, d. h. mit einem möglichst breiten Spektrum an Elementen gefordert. Die Beladung mit leichtflüchtigen metallorganischen Verbindungen, die über das Gaseinlassventil eingebracht werden können, hat sich als erfolgreiche und preiswerte Alternative zu einer MEVVA-Quelle erwiesen. Die Beladung mit Metallionen ist am Beispiel verschiedener Untersuchungen gezeigt. Der monoenergetische Elektronenstrahl gestattet neben der Untersuchung von Anregungs- und Ionisationsprozessen insbesondere die der wichtigen Rekombinationsprozesse des Strahlenden Einfangs und der Dielektronischen Rekombination. Der Einsatz eines Kristalldiffraktionsspektrometers erlaubt trotz einer aufwendigen Kalibrierung und sehr langen Messzeiten die Auflösung einzelner Übergänge in hochgeladenen Ionen. Hauptanwendungsfeld der Dresden EBIT wird der Einsatz als Ionenquelle sein. Aus den Untersuchungen des extrahierten Gesamtionenstroms können die Bedingungen für einen möglichst großen Ionenstrom und einen optimalen Ionenstrahltransport abgeleitet werden. Eine optimale Ausnutzung der Eigenschaften hochgeladener Ionen erfordert die Separation der einzelnen Ladungszustände. Der Nachweis der sehr kleinen Ionenströme erfolgt über die kapazitive Messung in einem Faradaycup. Die Messung der Ladungszustandsverteilung in Abhängigkeit von den Parametern der EBIT gibt zusätzliche Aufschlüsse über die Eigenschaften der Ionenfalle.
24

Better Sorry Than Safe? : An evaluation of Scandinavian acquirers participating in European mergers and acquisitions between 2010-2017

Joakimson, Anton, Lyrfors, Olle January 2021 (has links)
Mergers and acquisitions (M&A) are a popular way of growing a company. This is challenged by previous research that shows that an M&A-transaction generally harms the financial key metrics of the acquiring company. The main focus of this report is to examine if there is an effect on financial ratios for Scandinavian companies partaking in an M&A as an acquirer. The effect is captured by the movements in the key metrics return on equity (ROE), return on assets (ROA), return on invested capital (ROIC), EBIT-margin. In addition, both ESG-ranking and underlying non-financial values, like if the deal was domestic or not, the age of the executives and board gender diversity, are looked at for a better understanding of what differences there are between the performance of M&As.  A database of Scandinavian companies acting within Europe was created containing the specific deal characteristics over a period of three years prior as well as three years after the deal. The statistical methods used to analyze this data were Wilcoxon signed-rank test, bivariate Pearson Correlation and Independent Samples t-test. The generated results in the aggregated dataset showed a negative performance of ROE and ROIC in the period after the deal, compared to the period prior to the deal. This result was also seen in the sub-set of foreign deals with an additional negative performance of ROA for the acquirer while the sub-set of domestic deals did not show any significant negative performance in the period after the deal. We found that it was not possible to analyze the post-period effect on ESG-ranking as the data for our included companies was too scarce. Our findings suggest, when looking at our certain key metrics, that M&A-transactions are not economically justified and that executives might be partially motivated by something other than economic performance when deciding upon an M&A. It is furthermore possible to conclude that the disclosing of ESG data has not been a priority for companies in the past and continues to be ignored by the masses which makes it difficult to progress academically in this field.
25

Návrh zlepšení finančního plánování v podniku / Improvement of financial planning in trading company

Mazanec, Michal January 2007 (has links)
The financial situation and financial economy could be controlled by a whole range of indicators in the time progress and context so that the evaluation of the situation may reflect the whole economic state of the company and enable to point out causes of the actual situation. If the company shall be economically succesful, the financial planning and analysis has to be a part of the complex of the company´s financial management, because it provides a feedback between the expected effect of managing decisions and present. This diploma work is focused on detection of weak and strong characteristics of the company. All datas used in analysis are taken from the public sources and internal company documentation. The point of my diploma thesis was to present a financial analysis containing my theoretical experience, which I gained during my study at the VUT.Brno.
26

Podnikatelský záměr / Business Plan

Sikora, Petr January 2008 (has links)
This diploma work considers financial strategy of a company on financial analysis basis. Financial analysis evaluates past, present and expected future of the financial economy of the company. On the basis of these issues solutions for an improvement of the financial situation of the company as whole are suggested as well as in specific investment project.

Page generated in 0.025 seconds