• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 411
  • 10
  • 6
  • 6
  • 6
  • 6
  • 5
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 431
  • 202
  • 103
  • 98
  • 90
  • 79
  • 78
  • 71
  • 66
  • 63
  • 51
  • 51
  • 48
  • 47
  • 43
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
171

Utilização de ozônio no tratamento de águas residuárias da lavagem e despolpa do café / Use of ozone in the treatment of wastewater from the washing and pulping coffee

Carvalho, Marta Cristina Silva 21 February 2011 (has links)
Made available in DSpace on 2015-03-26T13:23:47Z (GMT). No. of bitstreams: 1 texto completo.pdf: 1765516 bytes, checksum: 4fbedf3e31cfced1feb83c5be1f48ef4 (MD5) Previous issue date: 2011-02-21 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / Needing for treatment alternatives of wastewater from coffee fruits processing stimulates the study of alternative methods, in view to new techniques aimed at enabling the removal of these effluent pollutant load. One of the alternatives that need to be studied is the application of chemical treatment with ozone gas, considering the high oxidizing power of this compound. This study aimed to evaluate the effect of ozonation process on physical, chemical, and biochemical characteristics of wastewater from washing and peeling/pulping (ARC) coffee and to verify the pH influence on efficiency of wastewater ozonation in treatment. For the ozonation process, a gas-washing bottle was used with a capacity of one liter. Ozone gas was injected into the bottle through a porous plate with a flow rate of one liter/min-1. The influence of different combinations of pH (3.7, 7.0, and 10.0), ozone gas concentration (4.3, 8.6, and 12.8 mg L-1), and ozonation periods (0, 30, 60, 90, 120, 150, and 180 min.) was evaluated. Data were statistically analyzed by multiple linear regression. According to results, it was concluded that the treatment of wastewater from coffee fruits processing with ozone for analysis of Biological Oxygen Demand (BOD), Chemical Oxygen Demand (COD), phenolic compounds, and apparent color does not appear to significantly affect the initial pH of the water in reducing their values during treatment. Thus, the removal of BOD, COD, and apparent color were higher with increasing ozone concentration, as the ozonation process occurred, resulting in maximum removal efficiencies of 11.0, 12.0, and 99.0%, respectively, for the concentration of 12.8 mg L-1 during 180 min. of ozonation. With regard to phenolic compounds, an increase in the removal percentage to ozone gas concentration of 8.6 mg L-1 was observed, with subsequent decrease in removal efficiency. The highest removal percentage of phenolic compounds was 68.0%, observed after ozonation and gas concentration of 8.6 mg L-1 for 180 min. Variables for total nitrogen, total suspended solids, and turbidity showed significant difference due to interaction between initial pH of wastewater and ozonation period. Concentration reduction of total nitrogen was more pronounced in the wastewater with lower pH, resulting in removal of 58.0% after 180 min. for pH equal to 3.7. With respect to total suspended solids variables and turbidity, a greater reduction was obtained during ozonation period, as they raised the initial pH of water. With respect to the total solids variables and total volatile solids, there was significant variation only due to the ozonation period, regardless of the gas concentration and initial pH of wastewater. Based on the results, it is possible to say that the use of ozone gas to treat wastewater from the coffee fruits processing is effective when compared to commonly used treatments for this effluent type, since it needs a short treatment period for more efficient removal of phenolic compounds, nitrogen, turbidity, and color. However, as most existing treatments, the treated wastewater with ozone gas alone did not respond to release some limits established by Brazilian legislation in force and further studies are needed to increase the process efficiency. / A necessidade de encontrar alternativas para o tratamento da água residuária proveniente do processamento dos frutos do cafeeiro estimula o estudo de métodos alternativos, visando a novas técnicas que possibilitem a remoção da carga poluidora desse efluente. Uma das alternativas que necessitam ser estudadas é o tratamento químico com aplicação de gás ozônio, haja vista o alto poder oxidante desse composto. Assim, objetivouse, com este estudo, avaliar o efeito do processo de ozonização nas características físicas, químicas e bioquímicas da água residuária resultante da lavagem e descascamento/despolpa do café (ARC) e verificar a influência do pH na eficiência da ozonização da água residuária em tratamento. Para o processo de ozonização, utilizou-se um frasco lavador de gás com capacidade de 1 L. O gás ozônio foi injetado no frasco, por meio de uma placa porosa, com uma vazão de 1 L min-1. Avaliou-se a influência de diferentes combinações de pH (3,7; 7,0 e 10,0), concentração do gás ozônio ( 4,3; 8,6 e 12,8 mg L-1) e períodos de ozonização (0, 30, 60, 90, 120, 150 e 180 min). Os dados foram submetidos à análise estatística por meio de regressão linear múltipla. De acordo com os resultados obtidos, foi possível concluir que o tratamento da água residuária do processamento dos frutos do cafeeiro com ozônio para as análises de DBO, DQO, compostos fenólicos e cor aparente não mostrou influência significativa do pH inicial da água na redução de seus valores durante o tratamento. Assim, as remoções de DBO, DQO e cor aparente foram maiores com o aumento da concentração de ozônio, à medida que ocorria o processo de ozonização, obtendo-se eficiências de remoção máximas de 11,0; 12,0 e 99,0%, respectivamente, para a concentração de 12,8 mg L-1 no período de ozonização de 180 min. Com relação aos compostos fenólicos, observou-se aumento no percentual de remoção até a concentração do gás ozônio de 8,6 mg L-1, com posterior decréscimo da eficiência de remoção. O maior percentual de remoção de compostos fenólicos foi de 68,0%, observado depois de 180 min. de ozonização e concentração do gás de 8,6 mg L-1. Para as variáveis nitrogênio total, sólidos suspensos totais e turbidez, verificou-se diferença significativa em decorrência da interação entre pH inicial da água residuária e período de ozonização. A redução da concentração de nitrogênio total foi mais acentuada na água residuária com menor pH, obtendo-se remoção de 58,0% depois de 180 min. para pH igual a 3,7. Com relação às variáveis sólidos totais, suspensos e turbidez, obteve-se maior redução durante o período de ozonização, à medida que se elevou o pH inicial da água. Com relação às variáveis sólidos totais e sólidos voláteis totais, ocorreu variação significativa somente em decorrência do período de ozonização, independentemente da concentração do gás e do pH inicial da água residuária. Com base nos resultados obtidos, é possível afirmar que o uso do gás ozônio no tratamento de águas residuárias provenientes do processamento dos frutos do cafeeiro é eficiente quando comparado aos tratamentos normalmente empregados para esse tipo de efluente, já que necessita de curto período de tratamento para obter eficientes remoções de compostos fenólicos, nitrogênio, turbidez e cor. Todavia, assim como a maioria dos tratamentos existentes, esta água residuária tratada com gás ozônio, isoladamente, não atendeu a alguns limites de lançamento estabelecidos pela legislação brasileira vigente, sendo necessários estudos posteriores para aumentar a eficiência do processo.
172

Água residuária de laticínio em co-digestão com dejetos de bovinos leiteiros / Dairy residual water co-digestion with dairy cattle manure

Fernandes, Aline [UNESP] 06 July 2016 (has links)
Submitted by ALINE FERNANDES null (aline.nands@hotmail.com) on 2016-09-03T19:35:06Z No. of bitstreams: 1 DISSERTAÇÃO__repositorio.pdf: 1283943 bytes, checksum: 04c78f479f55ad56dd7a52f0a5254481 (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2016-09-05T17:02:18Z (GMT) No. of bitstreams: 1 fernandes_a_me_bot.pdf: 1283943 bytes, checksum: 04c78f479f55ad56dd7a52f0a5254481 (MD5) / Made available in DSpace on 2016-09-05T17:02:18Z (GMT). No. of bitstreams: 1 fernandes_a_me_bot.pdf: 1283943 bytes, checksum: 04c78f479f55ad56dd7a52f0a5254481 (MD5) Previous issue date: 2016-07-06 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / A pecuária leiteira bem como a industrialização do leite produzem resíduos que podem impactar o meio se lançados de forma imprópria. Sendo assim, objetivou-se avaliar o efeito da co-digestão de água residuária de laticínio com dejetos bovinos em biodigestores do tipo batelada e contínuo sobre a produção de biogás e biofertilizante. O experimento foi dividido em duas fases. A primeira fase desenvolvida com biodigestores batelada e a segunda subdividida em dois períodos com biodigestores contínuos. Avaliou-se o efeito da inclusão de água residuária de laticínio (ARL) na primeira etapa: 0% de ARL, 50% de ARL, 77,5% de ARL, 100% de ARL e tratamento ARL. Para segunda fase no primeiro período tratamento com 0% de ARL e 50% de ARL. E no segundo período com tratamentos de 0% ARL e 63,5% ARL. Para análise dos dados considerou-se um delineamento inteiramente casualizado, utilizando-se o programa SAS® com nível de significância de 5%. Para a primeira fase, observou–se que o tratamento ARL foi o que apresentou menor produção de biogás (0,00753 m3) em relação aos demais. Para os potenciais de produção o tratamento com 50% de ARL apresentou as menores médias. Nos dois períodos da segunda fase, ou seja, com biodigestores contínuos, os resultados demonstram que os tratamentos contendo água residuária foram eficientes sem diferença de produção de biogás entre os tratamentos. O aproveitamento da água residuária para compor substrato em co-digestão com dejetos bovinos leiteiros apresentou condições favoráveis de produção e qualidade de biogás e biofertilizante. / The dairy farming and industrialization of milk produce waste that may impact the environment if disposed improperly. Thus, this study aimed to evaluate the effect of co-digestion of dairy production wastewater with cattle manure in biodigesters in the batch and continuous type on the production of biogas and biofertilizers. The experiment was divided into two phases. The first phase developed with batch digesters and second divided in two periods with continuous digesters. We evaluated the effect of the inclusion of dairy wastewater (DW) in the first stage: 0% of DW, 50% of DW, 77,5% of DW, 100% of DW and DW treatment. For the second phase the first treatment period with 0% and 50% DW. And in the second period with treatments of 0% and 63.5% DW. Data analysis was considered a completely randomized design, using the SAS® program with 5% significance level. For the first phase, it was observed that the DW treatment showed the lower production of biogas (0.00753 m3) compared to the others treatments. For the production potential treatment with 50% of DW had the lowest means. In the second phase in both periods, with continuous digesters, the results show that the treatments containing wastewater were effective and there is no difference in biogas production between the treatments. The use of wastewater to form substrate co-digestion of dairy cattle manure showed favorable production conditions and quality of biogas and biofertilizers.
173

Degradação simultânea de bisfenol A e carbamazepina em efluente de estação de tratamento de esgoto por processo foto-Fenton / Simultaneous degradation of bisphenol A and carbamazepine in effluent from sewage treatment plant using photo-Fenton process

Alamino, Andreza de França [UNESP] 19 August 2016 (has links)
Submitted by Andreza de França Alamino null (andreza.alamino@hotmail.com) on 2016-09-10T18:02:45Z No. of bitstreams: 1 dissertacao_versão_final_pdf_repositório_unesp.pdf: 1884907 bytes, checksum: 6161a04cdaac1c53204da25be3831d76 (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2016-09-13T14:20:36Z (GMT) No. of bitstreams: 1 alamino_af_me_araiq.pdf: 1884907 bytes, checksum: 6161a04cdaac1c53204da25be3831d76 (MD5) / Made available in DSpace on 2016-09-13T14:20:36Z (GMT). No. of bitstreams: 1 alamino_af_me_araiq.pdf: 1884907 bytes, checksum: 6161a04cdaac1c53204da25be3831d76 (MD5) Previous issue date: 2016-08-19 / O presente trabalho aborda a degradação simultânea de dois contaminantes emergentes, o plastificante bisfenol A (BPA) e o fármaco carbamazepina (CBZ), aplicando-se processos oxidativos avançados (POA), particularmente o processo foto-Fenton. Durante os ensaios de degradação, o BPA e a CBZ foram determinados por cromatografia líquida de alta eficiência (CLAE) em uma única análise, utilizando dois detectores acoplados em série, o detector de fluorescência (FLU) para o BPA e detector de arranjo de diodos (DAD) para a CBZ. Foi necessária a otimização das condições do método cromatográfico, tais como, composição da fase móvel, 50% etanol-água, vazão, 0,500 mL min-1, comprimento de onda de excitação e emissão para o BPA, 277 e 300 nm nesta ordem, e absorção para a CBZ de 286 nm ou 211 nm. Após a construção da curva analítica foram determinados os parâmetros analíticos como: linearidade, limites de detecção e quantificação. Os ensaios de degradação foram efetuados em duas matrizes distintas, água e efluente de estação de tratamento de esgoto, coletado antes do lançamento nos rios, objetivando desenvolver um método de degradação em baixas concentrações em amostras reais. Pela complexidade da matriz foi necessário fazer o “clean up” das amostras por extração em fase sólida (EFS) nas alíquotas retiradas durante as degradações no efluente. A faixa de recuperação da EFS foi avaliada em três níveis e atingiu de 82 a 84% para o BPA e de 92 a 99% para a CBZ. A velocidade de degradação tanto de BPA como de CBZ foi influenciada pela matriz, pois foi maior em água do que no efluente. O tempo de degradação em água foi de 60 minutos e em efluente de 90 minutos. A degradação de BPA atingiu 88% em água e 77% em efluente, enquanto que de CBZ atingiu 95% em água e 61% em efluente. A remoção de carbono orgânico dissolvido (COD) nas amostras de efluente foi avaliada, porém as concentrações de Fe(III) e H2O2 utilizadas, 12,0 μmol L-1 e 300 μmol L-1 nesta ordem, não foram suficientes para degradar a matéria orgânica do efluente, mas foram suficientes para a degradação dos compostos alvos na concentração de 250 μg L-1.
174

Aplicação da água residuária tratada e de adubação com lodo de esgoto na cultura do crambe / Application of treated wastewater and fertilization with sewage sludge in crop crambe

Louzada, Isabela Seixo de Brito [UNESP] 02 September 2016 (has links)
Submitted by ISABELA SEIXO DE BRITO LOUZADA null (isabelasblouzada@hotmail.com) on 2016-10-03T20:25:25Z No. of bitstreams: 1 Dissertação - LOUZADA, I. S. B..pdf: 1671597 bytes, checksum: 1f1840203317416aa8d58af8cd8f3b90 (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-10-05T20:07:04Z (GMT) No. of bitstreams: 1 louzada_isb_me_bot.pdf: 1671597 bytes, checksum: 1f1840203317416aa8d58af8cd8f3b90 (MD5) / Made available in DSpace on 2016-10-05T20:07:04Z (GMT). No. of bitstreams: 1 louzada_isb_me_bot.pdf: 1671597 bytes, checksum: 1f1840203317416aa8d58af8cd8f3b90 (MD5) Previous issue date: 2016-09-02 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O uso de efluente de esgoto tratado e de lodo de esgoto compostado representam uma boa oportunidade para o setor agrícola de suprimento hídrico e nutricional às plantas, além da agricultura ser um destino adequado, seguro e benéfico desses resíduos quando corretamente manejados. Assim, objetivou-se com esse estudo avaliar o efeito da água residuária tratada e do lodo de esgoto compostado como substituto parcial, total e em doses superiores à adubação nitrogenada convencional, no solo e na cultura do crambe. O experimento foi conduzido em ambiente protegido em vasos de PVC com volume útil de 45,5 L, no Departamento de Solos e Recursos Ambientais, pertencente à Faculdade de Ciências Agronômicas da Universidade Estadual Paulista "Júlio de Mesquita Filho" (FCA/UNESP), Botucatu/SP, no período de julho à outubro de 2015. Foi utilizado um delineamento inteiramente casualizado em arranjo de parcelas subdivididas; nas parcelas foram empregados dois tipos de água para irrigação, água potável e efluente de esgoto tratado, e nas subparcelas sete níveis de adubação nitrogenada, totalizando quatorze tratamentos com dez repetições. Os tratamentos dentro de cada parcela são representados por: T0 – sem adubação nitrogenada; T1 – 100% de adubação nitrogenada mineral; T2 – 50% de adubação nitrogenada mineral + 50% adubação nitrogenada proveniente do lodo de esgoto compostado; e T3, T4, T5 e T6 correspondem à 100%, 150%, 200% e 250% da adubação nitrogenada proveniente do lodo de esgoto compostado, respectivamente. Os dados relativos às variáveis estudadas foram analisados estatisticamente por meio do software SISVAR e submetidos à análise de variância à 5% de probabilidade, sendo as médias comparadas pelo teste de Tukey a 5% de significância. Optou-se por refazer a análise estatística dos tratamentos que receberam somente lodo de esgoto compostado, adotando-se a análise de regressão. O uso de efluente de esgoto tratado proporcionou incremento dos componentes desenvolvimento, rendimento e teor de óleo da semente. A substituição da adubação nitrogenada convencional pela adubação via lodo de esgoto compostado elevou o rendimento de grãos-planta, com melhor rendimento proporcionado pela dose máxima de N aplicada via lodo de esgoto compostado. O aumento das doses de lodo de esgoto no solo elevou o pH, a CTC, SB, V%, os teores de matéria orgânica, P, K, Ca, S, B, Cu, Fe, Mn e Zn, e o uso de efluente de esgoto tratado os teores de Mg, S e Mn. / The usage of treated sewage effluent and composted sewage sludge represents a good opportunity for the agricultural sector of water supply and plant nutrition, besides being an adequate, safe and beneficial end for the agricultural for these residues when correctly handled. Thus, this study was aimed to evaluate the treated sewage effluent and the composted sewage sludge as a partial substitute, total and in doses superior to the conventional nitrogen fertilization, on the soil and on the crambe culture. The experiment was conducted in a protected environment of PVC vases with useful volume of 45,5L, at the Department of Soils and Environmental Resources of Agricultural Sciences Faculty, belonging to Universidade Estadual Paulista "Júlio de Mesquita Filho" (FCA/UNESP), Botucatu/SP, between July and October of 2015. The experimental design was completely randomized in a split plot arrangement; using the plots two types of irrigation water, potable water and treated sewage effluent and the subplots seven levels of nitrogen fertilization, adding up fourteen treatments with ten repetitions. The treatments within each parcel are represented by: T0 – no nitrogen fertilization; T1 – 100% mineral nitrogen fertilization; T2 – 50% mineral nitrogen fertilizer; + 50% composted sewage sludge; and T3, T4, T5, T6 corresponding to 100%, 150%, 200% and 250% of nitrogen fertilizer from the composted sewage sludge, respectively. The data concerning the variables were analyzed statistically through the SISVAR software and were submitted to a variance analysis to 5% of probability, being those averages compared using the Tukey test to 5% of significance. It was opted to redo the statistical analysis of the treatments that only had received the composted sewage sludge, adopting the regression analysis. The use of treated sewage effluent provided increment of components development and production. The conventional nitrogen fertilization substitution by the composted sewage sludge fertilizer elevated the yield of grains–plant, with a better yield provided by the maximum dose of N applied through the composted sludge. In the soil, the increasing doses of sewage sludge elevated the pH, the CTC, SB, V%, content of organic matter, P, K, Ca, S, B, Cu, Fe, Mn and Zn, and the usage of treated sewage effluent elevated the levels of Mg, S and Mn.
175

Caracterização e tratamento do efluente de lavagem em empresa de reciclagem de plásticos para fins de reuso

Rodrigues, Elisangela Garcia Santos 27 March 2013 (has links)
Made available in DSpace on 2015-05-14T12:09:15Z (GMT). No. of bitstreams: 1 ArquivoTotal.pdf: 1961421 bytes, checksum: 973f1642f643f82ef2c4091be77d57aa (MD5) Previous issue date: 2013-03-27 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / In the steps of the process of plastics recycling, the washing process produces an effluent with high organic load that requires treatment for disposal. In order to evaluating the organic load physicochemical parameters were analyzed in order to establish the best form of treatment for the effluent reuse in a plastic recycler at the washing process. Sample collection was made in the washing tank at the end of the washing process at determined cycles around 12:00h. According to the obtained results the need arises for the treatment of effluent, both to frame it in the discard parameters established by the legislation of the national council of the environment (CONAMA), and to reuse it inside the recycler. As proposal was used for washing effluent treatment the coagulation/flocculation process, where was applied three types of coagulants (ferric chloride, aluminum sulfate and polychloride aluminum) at doses ranging from 5mg.L-1 of 65mg.L-1 and the Fenton oxidative process. For the effluent under study, it was concluded that the ferric chloride has a higher efficiency in the reduction of parameters analyzed, turbidity, pH, COD, BOD, TSS and TOC in relation to sulfate aluminum e polychloride aluminum, when comparing the physical and chemical characteristics of raw and treated effluent. Through the analysis it was found that the Fenton process has an efficiency on average of 92% of turbidity and 94% of COD and 90,5% of BOD, in reaction time of 60 minutes with agitation magnetic. The treated effluent presents values compatible for reuse. / Nas etapas do processo de reciclagem, a lavagem dos plásticos produz um efluente de elevada carga orgânica que requer tratamento para o descarte. Com intuito de avaliar a carga orgânica, os parâmetros físico-químicos foram analisados possibilitando estabelecer a melhor forma de tratamento para reciclagem do efluente tratado, gerado na lavagem dos plásticos de uma recicladora para fins de reuso. A coleta foi feita no tanque de lavagem no final de cada ciclo de lavagem em torno das 12h00. A partir dos resultados obtidos surge à necessidade do tratamento do efluente, tanto para enquadrá-lo nos parâmetros de descarte estabelecidos pela legislação do Conselho Nacional do Meio Ambiente (CONAMA), quanto para reusá-lo dentro da própria recicladora. Como proposta foi utilizado para o tratamento do efluente de lavagem o processo de coagulação/ floculação, sendo aplicados três tipos de coagulantes (cloreto férrico, sulfato de alumínio e policloreto de alumínio) em dosagens na faixa de 5mg.L-1 a 65mg.L-1 e o processo oxidativo avançado Fenton. Para o efluente em estudo, concluiu-se que o cloreto férrico tem uma maior eficiência na redução dos parâmetros analisados pH, turbidez, Demanda Química de Oxigênio (DQO), Demanda Bioquímica de Oxigênio (DBO), Sólidos Suspensos Totais (SST), Carbono Orgânico Total (COT) em relação ao sulfato de alumínio e o policloreto de alumínio, quando comparados as características físico-químicas do efluente bruto. Através das análises foi possível constatar que o processo Fenton apresentou uma eficiência em média 92% de turbidez e 94% de DQO, DBO 90,5% em tempo de reação de 60 minutos com agitação em que o efluente tratado apresenta valores compatíveis para o reuso.
176

Carvão ativado produzido a partir do endocarpo de coco da baía (Coccus Nucifera) aplicado no tratamento de efluente têxtil / Activated Carbon Produced from the endocarp of Coco Baía (Coccus Nucifera) applied in the treatment of textile effluent

Costa Junior, Silvanio Soares da 28 March 2014 (has links)
Made available in DSpace on 2015-05-14T12:09:39Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 2705810 bytes, checksum: eb7528a28bf11f243846ad12d09da42b (MD5) Previous issue date: 2014-03-28 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / This study investigated the treatment of an industrial textile effluent by combined physicochemical processes, coagulation/flocculation - activated carbon. Trials in Jar-Test using the same time for mixing and sedimentation, have improved organic matter and pollutants removal efficiency from the effluent for the coagulants (Al2(SO4)3 e FeCl3) employed. The treatment characterization for optimum concentration found was measured through the determination of SST, DBO, DQO, COT, nitrate, turbidity and surfactants content. For the parameters investigated, the percent removal in accordance with the best optimization trial were 85.6%, 88.9% and 96.2% for DQO, DBO and turbidity, respectively, using the coagulant FeCl3. For the adsorptive treatment of the pre-treated textile effluent, activated carbons were produced the endocarp of coconut (Coccus Nucifera), with chemical activated using Al2(SO4)3 and physical one using water vapor (steam). The ratio of activator:precursor effect on the activation were analyzed, as well as the carbonization temperature, retention time and type of activation on the textural properties of the activated carbons produced. The activated carbons were characterized by N2 adsorption to determine: SBET, SM, VP, VM, VMS and D. The CAQ232FQ carbon showed higher microporosity and SBET (1009 m2.g-1), and it was used in adsorption experiments. The CAQ232FQ carbon was also characterized by: MEV, Boehm, FTIR, TG, DTA, pH, pHPCZ and apparent density. Adsorption experiments with CAQ232FQ carbon were made for pre-treated textile effluent and synthetic sewage. The pH was not adjusted during the adsorption and the temperature was maintained at 26 ºC. The isotherms obtained for both effluents are better adapted to Freundlich model, however, adsorption processes for the pre-treated industrial effluent follows the kinetic model of pseudo-second order, differently to the synthetic industrial effluent which follows model of pseudo-first order. As a concluding remark, adsorption tests with CAQ232FQ carbon have proved to be effective for color removal, considering that the adsorption rate of the dye was higher than 97% in both effluents and the reduction rate of the analyzed parameters was higher than 99% for the industrial textile effluent. / O trabalho investigou o tratamento de um efluente têxtil industrial por processos físico-químicos combinados, coagulação/floculação carvão ativado. Ensaios em ―jar-test‖, utilizando o mesmo tempos de mistura e sedimentação, aperfeiçoaram e verificaram a eficiência de remoção de poluentes do efluente em relação aos coagulantes (Al2(SO4)3 e FeCl3) empregados, a caracterização do tratamento para a concentração ótima encontrada foi por meio das análises de SST, DBO, DQO, COT, nitrato, surfactantes e turbidez. Para os parâmetros investigados, o percentual de remoção de acordo com o melhor ensaio de otimização foram de 85,6%, 88,9% e 96,2% para DQO, DBO e turbidez, respectivamente, utilizando o coagulante FeCl3. Para o tratamento adsortivo do efluente têxtil pré-tratado foi produzindo carvões a partir do endocarpo de coco da baia (Coccus Nucifera) ativados quimicamente com Al2(SO4)3 e fisicamente com vapor d água. Analisou-se o efeito da proporção ativante/precursor, temperatura de carbonização, tempo de retenção e tipo de ativação sobre as propriedades texturais dos carvões produzidos. Os carvões foram caracterizados por adsorção de N2 para determinar: SBET, SM, VP, VM, VMS e D. O carvão CAQ232FQ apresentou maior microporosidade e SBET (1009 m2.g-1), sendo utilizado nos experimentos de adsorção. O carvão CAQ232FQ foi caracterizado também por: MEV, Boehm, FTIR, TG, DTA, pH, pHPCZ, e dens. aparente. Ensaios de adsorção com o carvão CAQ232FQ foram feitos para o efluente têxtil pré-tratado e para o efluente sintético. O pH não foi ajustado durante a adsorção e a temperatura foi mantida em 26oC. As isotermas obtidas para ambos os efluentes se ajustam melhor ao modelo de Freundlich, no entanto o processo de adsorção para o efluente industrial pré-tratado segue o modelo cinético de pseudo-segunda ordem, diferentemente do efluente industrial sintético que segue modelo de pseudo-primeira ordem. Em suma os ensaios de adsorção com o carvão CAQ232FQ se mostraram eficientes visto que a taxa de adsorção do corante foi superior a 97% para ambos os efluentes e a taxa de amenização dos parâmetros analisados foi superior a 99% para o efluente têxtil industrial.
177

Estudo da adsorção do corante reativo blue 19 por lama vermelha ativada por tratamento químico e térmico

Souza, Kelli Cristina de [UNESP] 17 August 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:31Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-08-17Bitstream added on 2014-06-13T18:59:01Z : No. of bitstreams: 1 souza_kc_me_bauru.pdf: 1427333 bytes, checksum: d2af9018310862c2fe34e56e2d8abbd2 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A indústria têxtil é responsável pela geração de efluentes que, normalmente, apresentam um nível indesejável de coloração devido à etapa de tingimento, onde utilizam-se corantes que, quando lançados nos corpos d'água, levam à alteração de sua qualidade e ocasionam efeitos danosos ao meio ambiente e à saúde humana. Em vista disso, este trabalho teve como objetivo utilizar a lama vermelha, resíduo gerado em larga escala na produção de alumínio, como meio adsorvedor do corante Reativo Blue 19, o qual possui grande aplicação industrial e características que dificultam sua remoção em solução aquosa por meio de tratamentos convencionais. Sendo assim, optou-se por ativar a lama vermelha através de tratamento químico (água do mar, nitrato de cálcio e peróxido de hidrogênio) e térmico (400ºC e 500ºC), visando identificar a interferência desses tratamentos no aumento de sua capacidade adsortiva. Para isso, foi realizada a caracterização das amostras de lama vermelha através da determinação do pH, condutividade elétrica, ponto de carga zero (PCZ) difração de raios - x (DRX) e área superficial específica, sendo que a análise granulométrica foi realizada somente para a lama vermelha in natura. Em seguida, visando determinar a capacidade adsortiva da lama vermelha ativada, foram construídas isortermas de adsorção, linearizadas segundo os modelos de Langmuir e Freundlich. Para efeito de comparação, a mesma metodologia foi aplicada ao carvão ativado visando determinar sua capacidade em adsorver o mesmo corante. Foi realizado o estudo da cinética de reação através dos modelos pseudo-segunda ordem, onde todas as amostras obedeceram ao modelo de pseudo - segunda ordem. Os resultados mostraram-se bastante promissores, sendo que a lama vermelha ativada por nitrato de cálcio a 500ºC apresentou uma... / The textile industry is responsible for the generation of effluents usually have an undersirable level of staining due to the step of dyeing, which is used dye which, when thrown into water bodies, leading to alteration of its quality and cause harmful effects the environment and human health. As a result, this study aimed to use the red mud, waste generated on a large scale in the production of aluminum, such as through adsorption of the dye Reactive Blue 19, which has a large industrial application and characteristics that hinder its removal in solution Aqueous by conventional treatments. Therefore, we chose to activate the red mud by chemical treatment (seawater, calcium nitrate and hydrogen peroxide) and thermal (400º C and 500º C) in order to identify the influence of these treatment in increasing its adsorption capacity. For this, we performed the characterization of samples of samples of red mud by determining the pH, electrical conductivity, point of zero charge (PZC) - ray diffraction (XRD) and specific surface area, and the particle size analysis was performed only for red mud in nature. Then, to determine the adsorptive capacity of activated red mud, adsorption isotherms were constructed, according to the linearized Langmuir and Freundlich models. For comparison, the same methodology was applied to activated carbon in order to determine their ability to adsorb the same dye. Was performed to study the kinetics of reaction through the pseudo-first model and pseudo-second order where all samples followed the type of pseudo-second order. The results were very promising, with the red mud activated by calcium nitrate at 500ºC showed a maximum adsorption capacity of 476.02 mg/g at pH 4. The results for the activated carbon did not indicate affinity between the adsorbate and adsorbate material, a factor... (Complete abstract click electronic access below)
178

Avaliação da presença da antineoplásico em água residuária de um hospital oncológico e do sistema de esgotamento sanitário municipal /

Zampieri, Denise Aparecida. January 2013 (has links)
Orientador: Sérgio Vicente Serrano / Banca: Lígia Maria Kerr / Banca: Luciano de Souza Viana / Resumo: Os medicamentos antineoplásicos são uma das classes de produtos farmacêuticos com maior potencial para causar efeitos negativos no ambiente. Várias fontes contribuem para a potencial contaminação do ambiente com esses medicamentos, como emissões da indústria ou descarte direto de produtos farmacêuticos nos domicílios, mas a principal fonte de compostos citostáticos no esgoto ou no ambiente são excreções (urina e fezes) de pacientes em tratamento. Neste estudo foi analisada a presença do antineoplásico 5-fluorouracil (5-FU) e sua quantificação nos efluentes de um hospital oncológico de grande porte e na rede municipal de tratamento de esgoto. Foram analisadas 10 amostras obtidas de um ponto distinto (A), a partir dos efluentes do Hospital de Câncer de Barretos (HCB) e 5 amostras foram obtidas de dois pontos diferentes (B e C) do efluente da Estação de Tratamento de Esgoto (ETE) da cidade de Barretos (ETEB), que tem como destino final o Ribeirão Pitangueiras. Observou-se a presença do fármaco na concentração de 26,7 a 733 μg/L em todas as 10 amostras de água residuária do HCB analisadas, os resultados foram muito superiores aos encontrados em outros trabalhos semelhantes realizados em outros hospitais. Também foi realizado o cálculo das concentrações previstas do agente citostático na água residuária do HCB, utilizando-se parâmetros como o consumo de 5-FU, o consumo de água e a fração de droga excretada na forma não metabolizada. Encontrou-se uma baixa correlação entre a concentração prevista e a concentração medida analiticamente. Esse baixo índice de recuperação pode ter ocorrido decorrente da excreção do fármaco realizada fora do ambiente hospitalar, de uma possível degradação da droga decorrente da instabilidade da molécula ou a perda de uma porção da droga adsorvida na matéria em suspensão dos efluentes. O impacto do descarte de 5-FU no meio ambiente foi avaliado através ... / Abstract: Anticancer drugs represent one of the classes of pharmaceuticals with the greatest potential to cause negative effects on the environment. Contamination of the environment with these drugs may occur from several sources, such as emissions from industry or direct disposal of pharmaceuticals in households, but the main source of cytostatic compounds in the environment occur through sewage emission or excreted fluids (feces and urine) of patients receiving treatment. In this study we analyzed the presence of the antineoplastic 5-fluorouracil (5-FU) and its quantification in the effluents originated from a large oncology hospital and in the local municipal wastewater system. We analyzed 10 samples obtained from a distinct collection site (A), from the effluents of the Barretos Cancer Hospital (HCB). Also, 5 samples were obtained from two different sites (B and C) in the effluent from the Sewage Treatment Plant in Barretos (ETEB), whose final destination is the stream known as Ribeirão Pitangueiras. Presence of 5FU was observed in concentrations ranging from 26.7 to 733 μg/L in all 10 samples of the wastewater originated at the HCB collected at site A. These results were far superior to those found in similar studies performed at other hospitals. The predicted concentrations of the cytostatic agent in the wastewater from HCB was calculated using parameters such as 5-FU consumption, water consumption and the fraction of drug excreted unmetabolized. We found a low correlation between the predicted concentrations and the measured concentrations. This low recovery rate may have occurred due to probable excretion of the drug occuring outside the hospital facilities, since the majority of the patients were ambulatory. Other possibilities are drug degradation due to instability of the molecule and loss of a portion of the drug adsorbed in suspended solid matter of the effluent. The possible impact of the emission of 5-FU to the ... / Mestre
179

Tratamento de efluente de curtume por biofiltro aerado Submerso pré-tratado com microfiltro de membrana /

Bahia, Adilson Silva. January 2014 (has links)
Orientador: Tsunao Matsumoto / Banca: Liliane Lazzari Albertin / Banca: Luis Fernando Rossi Léo / Resumo: Os efluentes do processo de industrialização do couro em curtumes apresentam, além de elevadas concentrações de matéria orgânica em termos de Demanda Química de Oxigênio (DQO) e Demanda Bioquímica de Oxigênio (DBO), altas concentrações de sólidos totais, suspensos e sulfeto, o que torna o tratamento destes efluentes problemático. O objetivo do presente trabalho foi avaliar a biotratabilidade dos efluentes de curtumes por meio do tratamento por Biofiltro Aaerado Submerso (BF) após pré-tratamento por membrana de microfiltração. Os resultados mostraram que pode haver a viabilidade técnica no uso de BF para remoção de matéria orgânica e sulfeto de águas residuárias industriais de curtume, pois atingiram, respectivamente, a remoção 84% e 98 % / Abstract: The effluents from leather tanning process have in addition to high concentrations of organic matter in terms of Chemical Oxygen Demand (COD) and Biochemical Oxygen Demand (BOD), high concentrations of total solids, total suspended solids and sulfide, which makes problematic the treatment of these effluents. The objective of this study was to evaluate the biotreatability of tannery effluent by submerged aerated biofilter after microfiltration membrane pretreatment. The results showed that can be used in the technical feasibility of BF removal of organic sulphide and industrial raw tannery wastewater as it amounted, respectively, removal to 84% and 98% / Mestre
180

Variação da comunidade planctônica e fatores físico-químicos da água em dois sistemas de aquicultura /

Millan, Rodrigo Ney. January 2012 (has links)
Orientador: Lucia Helena Sipauba Tavares / Banca: Márcia Noélia Eler / Banca: Claudinei da Cruz / Banca: Antonio Fernando Monteiro Camargo / Banca: Joao Batista Kochenborger Fernandes / Resumo: O trabalho objetiva avaliar a importância da comunidade planctônica associando à qualidade da água nos principais compartimentos das pisciculturas estudadas: água de abastecimento, cultivo de organismos aquáticos e efluente. Foram realizadas coletas mensais durante um ano em dois ecossistemas aquícolas: um centro de pesquisa em aquicultura (CAUNESP) e um pesque-pague, localizados nas coordenadas geográficas 21º15'S e 48º18'O, amostrando 4 pontos em cada estabelecimento: nascente, água de abastecimento após tratamento, saída do sistema e efluente final após tratamento. Procedeu-se análise física e química da água e da comunidade planctônica em todos os pontos amostrados. Verificou-se que a água de abastecimento dos dois sistemas aquícolas é de boa qualidade para o cultivo de organismos aquáticos e que a passagem da água de nascente pelo banco de macrófitas foi benéfica para a comunidade planctônica. O estudo confirmou que o ciclo hidrológico, regime alimentar dos organismos cultivados e disposição sequencial de tanques foram variáveis promotores de mudanças na comunidade planctônica. O agrupamento funcional aplicado ao fitoplâncton e Rotifera (relação guilda) respondeu satisfatoriamente às mudanças do grau de trofia ocorridas no ambiente, podendo ser utilizados para monitoria destes ambientes. Além disso, demonstra a importância da construção de um sistema de tratamento no efluente de pisciculturas, propiciando remoção de nutrientes e alteração da constituição planctônica, visando melhoria das condições limnológicas da água de escoamento para o ambiente / Abstract: The importance of the plankton community associated to water quality in the main compartments of the fish farms such as, water supply, cultivation of aquatic organisms and effluent, is evaluated. The samplings' abiotic and biotic data were carried out monthly in two fish farms (21º15'S and 48º18'O) where four sampling points in each were evaluated, or rather, well, water supply after treatment, pre- and post-treatment wastewater. Analyses of the physical and chemical factors and of the plankton community in all the sampled points were undertaken. Results show that the water supply of the two fish farms indicated good water quality for the cultivation of aquatic organisms and that the passage of spring water through the macrophyte bank was beneficial to the plankton community. Current study confirmed that the hydrological cycle, the diet of cultured organisms and tank sequential disposal were factors that triggered changes in the plankton community. The functional group applied to phytoplankton and Rotifera (guild ratio) satisfactorily responded to changes in the environment's trophic level and may be used for the monitoring of environments. Furthermore, it demonstrated the importance of building a treatment system in fish farm effluents through the removal of nutrients and plankton, and aimed at improving the limnological conditions of runoff water into the environment / Doutor

Page generated in 0.1093 seconds