• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Environmental Performance of the Försäkringskassan IT Infrastructure : A Green-IT case study for the Swedish Social Insurance Agency

Honée, Caspar January 2013 (has links)
This Green IT case study commissioned by Försäkringskassan (FK), the Swedish National Social Insurance Agency, quantifies the environmental performance of the IT infrastructure (IT-IS) in use during 2010 in a lifecycle perspective. Adopting a system view in Green IT analysis can mitigate risks of problem shifts. IT-IS concerns the equipment that enables office automation and external web application services. The size of the FK IT-IS is in the order of 300 branch offices with 14000 pc’s, 2100 printers and a 1 MW data centre hosting 1200 servers, 5 Petabyte of central data storage and serving about 80 key business applications. The carbon footprint of the FK IT-IS in 2010 accounts to 6.5 kiloton CO2-equivalents. The total environmental impact is calculated across 18 themes and expressed as a single indicator eco score amounting to 822.000 ReCiPe points. The contribution of capital goods is large with 44% of the carbon footprint and 47% of the eco score linked to emissions embedded in material equipment. The environmental effects from distributed IT deployed at local office sites, dominate at two thirds of the total FK IT-IS impacts. Important drivers in the local office sites category are the relatively short economic life span of pc equipment and the significant volume of paper consumed in printing activities. Within the data centre category, operational processes dominate the environmental impacts and are linked to intensive power use. In comparison to industry benchmark scores, the data centre infrastructure energy efficiency (DCiE) is relatively low at 57%, or 59% when credited for waste heat utilisation. Airflow containment measures in computer rooms are identified for efficiency improvement. Enhanced airflow controls also act as a prerequisite to better leverage opportunities for free cooling present at the location in northern Europe.  With regards to the data centre hosted IT, environmental impacts linked to storage services dominate and remarkably exceed those of servers. / Denna fallstudie inom Grön IT på uppdrag av Försäkringskassan (FK) kvantifierar IT-infrastrukturens (IT-IS) miljöprestanda i ett livscykelperspektiv under 2010. Att införa ett systemperspektiv inom Grön IT analys kan lindra riskerna av problemväxling. IT-IS avser utrustning som möjliggör kontorsautomatisering och externa webbapplikationer. FK IT-IS omfattar 300 kontor med 14,000 datorer, 2,100 skrivare och ett 1 MW datacenter med 1,200 servrar, 5 Petabyte central datalagring och 80 huvudsakliga applikationer. Koldioxidavtrycket av det totala FK IT-IS utgör 6,5 kiloton CO2-ekvivalenter för 2010 . Den totala miljöpåverkan är beräknad över 18 miljöteman och anger som en enda indikator ekobetyget på 822,000 ReCiPe poäng . Kapitalvaror bidrar stort, med hela 44% av koldioxidutsläppen och 47% av ekobetyget kan härledas till inbäddade utsläpp i material utrustning. Miljöeffekterna av de lokala kontorens IT dominerar med två tredjedelar av den totala FK IT-IS miljöpåverkan. Viktiga faktorer i kategorin lokala kontor är kapitalvarornas relativt korta ekonomiska livslängd samt de betydande volymer av skrivarpapper som används.   Inom datacenterkategorin domineras miljöpåverkan av de operativa processerna som är kopplade till intensiv el förbrukning. I jämförelse med branschstandarden är energieffektiviteten av datacentrets infrastruktur (DCiE) relativt låg, med 57%, alternativt 59% när användandet av spillvärme inräknas. Luftflöde inneslutningsåtgärder i datorsalar identifieras för effektivisering. Förbättrad luftflödesinneslutning i datahallarna är identifierad som en energieffektivisering. Den förbättrade luftflödeskontrollen är också ett krav för att bättre kunna utnyttja möjligheterna för fri kyla som finns i Norra Europa.  Med avseende på datacentrets IT, domineras miljökonsekvenserna kopplade till lagringstjänster och överstiger anmärkningsvärt effekterna från servrarna. / Miljöutredning Grön IT på Försäkringskassan - examensarbeten

Page generated in 0.0204 seconds