• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5783
  • 109
  • 97
  • 84
  • 84
  • 83
  • 55
  • 37
  • 29
  • 21
  • 21
  • 18
  • 3
  • 3
  • 1
  • Tagged with
  • 6029
  • 3373
  • 2538
  • 1559
  • 1414
  • 1184
  • 959
  • 777
  • 749
  • 729
  • 672
  • 662
  • 615
  • 611
  • 525
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1401

Estudo da distribuição de temperaturas em ambientes condicionados por evaporador hi wall /

Ribeiro, Caio Augusto Garcia. January 2018 (has links)
Orientador: Vicente Luiz Scalon / Banca: Antonio Luiz Pacifico / Banca: Alcides Padilha / Resumo: O ar-condicionado tem-se tornado um dos grandes responsáveis pelo aumento da demanda de energia elétrica no Brasil e no mundo, pois com o desenvolvimento econômico combinado a redução de preço dos equipamentos de ar-condicionados, mais residências e comércios os utilizam em busca de conforto térmico. Mas o uso pode acarretar em um aumento considerável na conta de energia, já que o ar-condicionado é o aparelho doméstico com alto consumo de energia. A solução imediata apontada por Sivak (2009) e Shan et al. (2013) para que o crescimento do uso de arcondicionado não provoque uma crise energética no mundo seria desenvolver aparelhos com a mesma qualidade de refrigeração dos atuais, mas que consumiriam bem menos energia. O aparelho mais utilizado em residências, pequenos comércios e escritórios, é o split system, com o evaporador do tipo Hi-wall, equipamento que tem algumas limitações em relação a sua distribuição de ar, que provoca bolsões de ar quente e frio no mesmo ambiente, além de provocar desconfortos localizados. O controle desse evaporador é baseado na temperatura de retorno, ou seja, se a temperatura no retorno não atingir a temperatura estabelecida o mesmo opera em sua potência máxima por um tempo maior que o necessário, desperdiçando assim energia elétrica, ou a temperatura pode ser alcançada antes no retorno do que no ambiente, provocando assim desconforto térmico por mais tempo. Assim, será proposta neste trabalho uma solução numérica, utilizando um código CFD, a par... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Air conditioning has become one of the main factors responsible for the increase in the electric demand in Brazil and in the world, since with economic development combined with the price reduction of air conditioning equipment, more residences and businesses use them to reach thermal comfort. But the use can lead to a considerable increase in the energy bill, since air conditioning is the household appliance with a high energy consumption. The immediate solution pointed out by Sivak (2009) and Shah et al. (2013), so that the growth of the use of air conditioning does not cause an energy crisis in the world, would be to develop devices with the same quality of refrigeration of the present, but that would consume much less energy. The most commonly devices used in residence, small shops and offices, are Split System, whit a high wall as internal unit, this evaporator has some limitations in the air distribution, which causes hot and cold zones in the same environment, as well as causing localized discomfort. The evaporator control is based on the return temperature, so if the return temperature does not reach the set temperature, the Air Conditioner will operate at its maximum power for a time longer than necessary, thus wasting electrical energy or the set temperature can be reached before in the evaporator than in the environment, thus causing thermal discomfort for longer. Thus, a numerical solution, using a CFD code, will be proposed using the energy-difference equations c... (Complete abstract click electronic access below) / Mestre
1402

Proposta de conservação de energia elétrica aplicada ao campus de São Carlos - USP / not available

Pereira, Alexandre Cristiano 22 April 1998 (has links)
Atualmente, diante dos possíveis riscos de falta no fornecimento de energia elétrica no Brasil, surge a necessidade de se educar os consumidores a utilizar corretamente a energia elétrica, pois é mais barato conservar energia do que produzi-Ia. Na busca de solucionar a má utilização da energia elétrica em um campus universitário, levantam-se as características da instalação existente por meio de um equipamento registrador/medidor de grandezas elétricas. De posse destes dados, descrevem-se os problemas de consumo e de dimensionamento dos equipamentos encontrados nas instalações internas, a fim de se apontarem soluções técnicas viáveis para que se possa ter o uso racional de energia elétrica, as quais também poderão ser utilizadas em quaisquer outros centros consumidores. Além disto, abordam-se aspectos relativos ao gerenciamento das instalações existentes, visando-se o correto uso da energia elétrica, independentemente das condições em que se encontram as instalações. E dentro do possível, analisam-se as medidas sugeridas, o que demonstra a viabilidade das mudanças, frente à manutenção dos gastos existentes. / Due to the current possible risks to electric energy supply in Brazil, there is the need of making the consumers aware of how to use electric energy correctly, because it is cheaper to conserve energy than to produce it. Seeking to correct the use of electric energy in a university campus, characteristics of the existent installation were researched by means of recording/measuring equipment of electric variables. With this data provided is described the problems of consumption and use of the equipment found in the intemal facilities, with the purpose of aiming at viable technical solutions as to the rational use of electric energy, not only locally but in any other consumer centers. Furthermore, some aspects related to the management of the existent facilities were approached with a view to using electric energy correctly, independently of the conditions which of facilities are met. Suggested measures are analyzed for the sake of evaluating the viability the proposed changes, with regard to the maintenance of the existent expenses.
1403

Revisão tarifária e diferenças regionais: Um estudo de concessões de distribuição de energia elétrica no Brasil / TARIFF REVIEW AND REGIONAL DIFFERENCES: A Study of concessions for the distribution of electric energy in Brazil

Brito, Erico Henrique Garcia de 29 January 2010 (has links)
A partir de estudo do histórico da indústria de energia elétrica no Brasil, de revisão de conceitos de Direito Administrativo, teoria geral de concessões de serviços públicos e política de preço aplicada a monopólios naturais, o trabalho apresenta o estudo de caso de duas empresas de fornecimento de energia elétrica privatizadas a partir da regulamentação do art. 175 dispositivos da Constituição Federal de 1988, através da publicação da Lei nº 8.985/1995, conhecida como Lei de Concessões. A Lei em referência possibilitou que serviços de utilidade pública cuja atividade era altamente controlada pelo governo, a exemplo do fornecimento de energia, telecomunicações, entre outros, tivessem sua prestação delegada à iniciativa privada, passando o Estado a exercer apenas as tarefas de fiscalizador e regulador dos serviços, na figura de autarquias de regime especial: as agências reguladoras. As condições da prestação dos serviços públicos, como a forma de reajuste e revisão das tarifas, foram estabelecidas em contratos de concessão assinados entre a União e os novos concessionários. No segmento de distribuição de energia elétrica, entretanto, as condições contratualmente pactuadas para preservação das tarifas não têm sido devidamente observadas, provocando distorções nos mercados das concessionárias, conseqüentemente sobre os seus respectivos consumidores. / ABSTRACT Beginning from the study of the history of Brazils electric energy industry, the review of Administrative rights and obligations concepts, general theory of public utility concessions, to the price policy applied to Natural Monopolies, this Dissertation presents the case study of two electric energy distribution companies, which were privatized by means of Law nº 8.987/1995, know as Law of Concessions, that guides Article nº 175 of the Federal Constitution of 1988. The Law made it possible for public utilities whose activities were highly regulated by the Government, such as the distribution of electric energy, telecommunications, among others, to be granted to the entrepreneurial initiative, where the State would only act as a regulating and inspecting agent, through regulatory agencies. The terms of rendering the service of public utilities, such as tariff policies, were established in concession contracts signed between the Union and the new concessionaires. In the electric energy distribution sector, however, these contractual conditions to establish and preserve tariffs have not been dully observed, causing distortions in the markets served by the concessionaires and consequently on their respective consumers.
1404

Uma contribuição para o cálculo simplificado de perdas técnicas regulatórias em redes otimizadas de distribuição de energia elétrica. / A contribution to the simplified calculation of regulatory technical losses in optimized networks of the electrical distribution system.

Antonelli, Denis 06 December 2013 (has links)
A dissertação aborda atributos das redes de média e baixa tensão que estão sujeitos a incerteza em sua determinação e são requeridos pelo modelo simplificado de cálculo das perdas técnicas, aqui denominado como MSCPRO, e que foi utilizado pela ANEEL ao longo do 2º ciclo de revisão tarifária para cálculo das perdas técnicas regulatórias das distribuidoras de energia. Para as redes de média tensão, devem ser determinados atributos de suas redes como, por exemplo, ângulo de ação e área de atuação, que possuem subjetividade em sua determinação. Já para a baixa tensão, deve ser realizada a classificação de cada rede em uma das cinco tipologias otimizadas utilizadas pelo modelo MSCPRO no cálculo das perdas técnicas deste segmento. Diante disto, é proposta nesta dissertação, para o segmento de redes de média tensão, uma metodologia para determinação de atributos sujeitos à incerteza que melhor descrevem as redes reais a partir da análise da distribuição das cargas. Ademais, é proposta uma formulação genérica para alimentadores cujo tronco é composto por mais de um tipo de cabo. Já para as redes de baixa tensão, são propostas quatro diferentes técnicas que se apoiam basicamente em modelo heurístico, classificadores hierárquicos e modelos estatísticos de agrupamento aglomerativo para classificação destas redes em uma das cinco tipologias otimizadas. / The dissertation discusses about descriptors attributes of medium and low voltage networks which are subject to uncertainty in their determination and are required the calculation of technical losses by the simplified model, here so-called as MSCPRO, and was used by ANEEL during the 2º tariff cycle review for calculation of regulatory technical losses of power distributors. For medium voltage networks, it must be determined some network attributes, such as, action angle and area which do not have specific methodology for its determination. As for the low voltage networks, the classification should be performed for each one of the five optimized network types used by the model MSCPRO in the calculation of technical losses in this segment. Given this, it is proposed in this dissertation, for the segment of medium voltage networks, a methodology for determining descriptors attributes subject to uncertainty that best describe real networks from the analysis of the loads distribution. Furthermore, it is proposed a generic formulation for feeders whose trunk is composed of more than one type of cable. For low voltage networks, it is proposed four different techniques that are mainly based on heuristic model, hierarchical classifiers and statistical models for agglomerative clustering classification of these networks into one of five types optimized.
1405

Eficácia da utilização simultânea de aparelhos de estimulação elétrica nervosa transcutânea (TENS) em pacientes portadores de Fibromialgia / Efficacy of the use of two simultaneously TENS devices for Fibromyalgia pain

Chubaci, Eliana Fazuoli 06 September 2012 (has links)
INTRODUÇÂO: Fibromialgia é caracterizada como síndrome, a qual inclui dor muscular, fadiga e distúrbio do sono. Ansiedade e depressão estão freqüentemente associados, porém a causa é desconhecida. A intensidade da dor piora ao se deitar, durante a noite e no despertar. Normalmente a dor se difunde na região lombar e cervical. A TENS é um método não medicamentoso, estabelecido para controle da dor, o qual minimiza o consumo de analgésicos. OBJETIVOS: Este estudo visou avaliar a utilização de dispositivos de TENS simultâneos em pacientes portadores de Fibromialgia. MÉTODOS: Após aprovação do Comitê de Ètica em Pesquisa e consentimento, 39 pacientes portadores de Fibromialgia foram avaliados de forma prospectiva, aleatória e duplamente-encoberta. Avaliou-se a utilidade clínica de um novo, muito pequeno e leve dispositivo de a TENS (TANYX). Dois dispositivos de TENS, foram aplicados de forma simultânea em cada paciente: 1) na região lombar (perpendicular à coluna sobre L5), e 2) na região cervical (perpendicular à coluna, entre C7 e T1), durante 20-min, a cada 12 horas, durante 7 dias consecutivos (antes de se deitar, à noite, e antes de se levantar, pela manhã). Os pacientes foram divididos em 3 grupos (n=13). O grupo placebo (GP) utilizou adesivos que não transmitiam estímulo elétrico, semelhantes aos originais. O grupo de únicoTENS (TENS-1) (n=13), utilizou um adesivo de TENS ativo na área mais dolorida (cervical ou lombar) e placebo na área menos doloroa. O terceiro grupo (TENS-2) utilizou dois adesivos ativos de TENS nas áreas cervical e lombar, simultaneamente. Para controlar a dor, diclofenaco (50mg) foi utilizado como analgésico de resgate, até três vezes ao dia. Foram avaliados a intensidade da dor através da escala numérica visual (ENV 0-10 cm), consumo de analgésicos de resgate, qualidade do sono e fadiga. RESULTADOS: Os pacientes foram demograficamente semelhantes. 36 pacientes completaram o estudo. Três pacientes do grupo placebo desistiram no 4o dia de ausência de alívio da dor. A avaliação entre cada grupo antes e após o tratamento revelou que pacientes do grupo placebo não apresentaram alívio da dor (ENV 8 cm, p>0,05), da fatiga, ou melhora do padrão de sono, enquanto o grupo TENS-1 apresentou diminuição de 2,5 cm na ENV para dor (ENV anterior 8,5 cm e após 6 cm) (p<0,05). Finalmente, o grupo TENS-2 referiu redução de 4 cm na intensidade da dor (ENV anterior ao tratamento 8,5 cm e 4,3 cm após tratamento) (p<0,02). O consumo de analgésicos diários foi menor para TENS-1 (p<0,05) e TENS-2 (p<0,02). A comparação entre os 3 grupos revelou que a analgesia, qualidade de sono e melhora da fadiga foi: grupo TENS-2 > TENS-1 > GP (p<0,05). Os participantes consideraram os aparelhos ativos úteis. Não foram observados efeitos adversos. CONCLUSÕES: enquanto a aplicação de um dispositivo de TENS na área dolorida, lombar ou cervical, amenizou a dor em pacientes portadores de fibromialgia, a fadiga e a qualidade do sono foram minimizadas apenas quando dois dispositivos foram utilizados, demonstrando que este novo dispositivo pode ser adjuvante para dor da fibromialgia. / BACKGROUND: Fibromyalgia is characterized by a range of symptoms that include muscle pain, fatigue and sleep disorders. Anxiety and depression are often also present, and the cause is unknown. Worst pain is normally felt during bedtime, at night and before waking up in the morning, and pain is normally widespread at the low back and cervical area. Transcutaneous electrical nerve stimulation (TENS) is an established method for pain relief, which does not involve the use of medication and can be advantageous, as adjuvant, for pain control. OBJECTIVES: The purpose of the study was to evaluate the effectiveness and safety of the use of two simultaneously new TENS devices for Fibromyalgia pain. METHODS: The local Ethics Committee approved the study, and informed consent was obtained. This prospective, double-blind randomized study evaluated the clinical utility of a new, very small and light, high frequency TENS device (TANYX) in 39 patients suffering from Fibromyalgia. Two TENS device were applied simultaneously in each patient: 1) at the lower back (perpendicular to the vertebrae canal, at the level of the 5th lumbar vertebrae), and 2) centrally above and below the space between the C7 and T1 spinous processes, perpendicular to the spine. The two devices were applied during 20-min at 12-hour interval during 7 consecutive days (Before bed-time and just after waking up in the morning). Patients were randomly divided into three groups (n=13): For the placebo group (PG), the two devices did not transmitted electrical stimulus, although they were externally similar to the active ones. The single-TENS group (STG) had applied one active TENS device at the worst area of pain (low back or cervical), and the placebo device at the less painful area. The third group double-TENS group (DTG) applied both active TENS devices at the low back and cervical areas. Diclofenac (50 mg) up to three times daily was used as rescue analgesic if necessary for pain control. The efficacy measures were pain relief evaluated on a visual analogue scale (VAS 0-10 cm),, reduction in use of daily analgesic tablets, quality of sleep, and fatigue. MAIN RESULTS: Patients were demographically similar. 36 patients completed the study. Three patients from the PG give up the study on the fourth day for absence of any pain relief. The evaluation within groups revealed that patients from DPG refereed no pain relief when compared to their previous VAS pain score (8-cm, p>0.05), while patients from the STG refereed improvement of 2.5 cm in the pain VAS (previous 8.5 cm compared to 6-cm after treatment) (p<0.05); and the DPG refereed daily maintained reduction of 4 cm in the VAS-pain (previous 8.5-cm to 4.3-cm) (p<0.02). Concurrent daily consumption of analgesic tablets was reduced in both STG (p<0.05) and DTG (p<0.02). Comparison among groups revealed that analgesia, as well as quality of sleep and disposition was: DTG > STG > PG (p<0.05). Participants subjectively found the active device useful. No adverse effects were observed. CONCLUSIONS: while the application of one active TENS device at either the lower back or cervical area improved pain relief in patients suffering from Fibromyalgia pain, the pain and fatigue were further improved when two actives devices were simultaneously applied, reflecting this new device an useful adjuvant for Fibromyalgia pain.
1406

Análise da matriz de geração de energia elétrica no Brasil: uma aplicação da teoria de portfólios. / Assessment of the brazilian electric energy generation matrix: a portfolio theory application.

Oliveira, Lucas Lyrio de 09 February 2017 (has links)
Este trabalho aplica a teoria moderna de portfólios para a definição da participação de cada fonte de geração de energia elétrica, em cada região brasileira, para que a demanda por eletricidade do país prevista pela Empresa de Pesquisa Energética para o ano de 2024 seja atendida. As composições das fontes foram analisadas sob a perspectiva dos custos envolvidos no processo de geração, transmissão e distribuição de energia elétrica, levando em consideração restrições operacionais como potencial de geração das fontes, limites de intercâmbio entre regiões e limites mínimo e máximo de geração de cada fonte em cada região. O risco em relação ao custo foi avaliado sob a ótica do desvio padrão e do conditional value at risk, e as diferenças entre essas duas medidas de risco, quando aplicadas para definição de matrizes energéticas, foram estudadas. Os modelos desenvolvidos foram aplicados sob dois cenários diferentes, sendo um considerando condições normais para a quantidade de oferta de energia, e outro considerando um cenário de stress na oferta de energia da região sudeste/centro-oeste, deste modo a influência das restrições de transmissão na composição da matriz pôde ser avaliada. As soluções obtidas no modelo sob condições normais de oferta foram comparadas com a matriz projetada para o Brasil no Plano Decenal de Expansão de Energia 2024. / This work applies modern portfolio theory for defining the participation of each electricity generation source, in each Brazilian region, in order to meet the electricity demand in the country for the year 2024, according to the Energy Research Company forecasting. The compositions of the sources were assessed under the perspective of the incurred costs during the processes of electricity energy generation, transmission and distribution. The risk associated to the costs were assessed under the light of the standard deviation and the conditional value at risk, and it was studied the differences between these two risk measures when they are applied for energy matrixes definition. The developed models were applied for two different scenarios, the first one considering normal conditions for the amount of electricity offer, and the second considering generation shortfall in the regions Southeast and Midwest, then the effect of transmission constraints was analyzed. The obtained solutions for the normal offer conditions were compared to the Brazilian energy mix projected by the Energy Research Company in the Energy Expansion Planning for 2024.
1407

Um modelo para gerenciamento de riscos em instituições não financeiras: aplicação ao setor de distribuição de energia elétrica no Brasil. / A model for managing risks in non-financial institutions: applicability to brazilian distributors of electricity.

Perobelli, Fernanda Finotti Cordeiro 18 June 2004 (has links)
O gerenciamento de riscos é um assunto que assume, crise após crise, papel relevante no ambiente das instituições não-financeiras. A despeito, entretanto, da importância crescente do assunto, discussões acerca da implementação de um modelo capaz de avaliar os riscos aos quais as empresas estão expostas ainda são incipientes. Considerando a existência desta lacuna e a importância do tema para as empresas, este estudo propõe a construção de um modelo teórico para mensuração do fluxo de caixa em risco e o aplica a empresas pertencentes ao setor de distribuição de energia elétrica no Brasil. Tal modelo deve ser capaz de informar a probabilidade de uma empresa não dispor de recursos para honrar seus compromissos em determinada data de pagamento futura, ou vértices do fluxo. / Risk management becomes, crisis after crisis, a widely discussed topic in the non-financial institutions environment. Besides its importance to those institutions, discussions on models capable of evaluating risks faced by companies are still premature. Considering this lack and the theme’s importance to non-financial institutions, this work proposes a theoretical model, which aims to measure firms´ cash flow-at-risk. Afterwards, the proposed model is applied and tested in Brazilian Electric Sector companies. Such a model may be able to return the probability that a company faces a financial distress, for not being able to make due payments in the set dates.
1408

A corrente de fuga como parâmetro indicativo do estado de degradação de materiais poliméricos de rede compacta de média tensão, instalados em ambientes agressivos. / The leakage current as a parameter to indicate the degradation of polymeric material of distribution line spacer, located in agressive environment.

Pinheiro, Walter 14 April 2008 (has links)
Este trabalho apresenta os resultados obtidos em uma pesquisa, visando utilizar a corrente de fuga como parâmetro indicativo do estado de degradação de materiais poliméricos de rede compacta de média tensão, instalados em ambientes agressivos. Testes foram realizados em laboratório de modo a investigar o comportamento da corrente de fuga com o estado de degradação do material polimérico. Os resultados mostram que a corrente de fuga pode fornecer informações valiosas sobre a degradação. Uma análise minuciosa das características da corrente de fuga mostrou que a freqüência de ocorrência da razão terceira harmônica sobre a componente fundamental é a que melhor caracteriza o fenômeno da degradação. Novos testes foram realizados de forma a definir valores de referência para sua utilização como controle de campo para subsidiar a manutenção preventiva. Para o estado de atenção, foi estabelecida freqüência de ocorrência de 50 para a relação entre 0,35 e 0,40 para um período de 24 horas. Para o estado de alerta, foi estabelecida a freqüência de ocorrência de 80, para um período de 24 horas. Um equipamento foi construído e instalado para indicação no caso de ocorrência de trilhamento elétrico e erosão de materiais poliméricos de uma rede compacta instalada na orla marítima. / This paper presents results obtained after research, aiming at the utilisation of the leakage current to indicate the degradation of polymeric material of distribution line spacer and covered cables located in agressive enviroment. Tests were performed at the laboratory in order to investigate the behavior of the leakage current as function of the stage of degradation of polymeric material. The results showed that the leakage current can provide valuable information about the degradation. A closer analysis of the leakage current caracteristics revealed that the frequency of occurrence of the ratio of third harmonic to fundamental component is the the one that best characterize the degradation phenomenon. New analysis were carried out in order to define reference values to be used in the field, obtaining frequencie of occurrence of 50 and 80, for a ratio between 0,35 and 0,40, in a period of 24 hours, for the warning state and the preventive maintenance alert, respectively. A device was built and installed to indicate tracking and erosion of polymeric material in distribution lines located near the coast.
1409

Análise de funções de um conversor de protocolos de comunicação para automação elétrica, baseado na utilização da linguagem de modelagem unificada. / Protocol functions analise for electric automation using unified modeling language.

Bertazini, Enzo 05 May 2006 (has links)
A evolução das técnicas de desenvolvimento de sistemas de software tem trazido melhorias na qualidade dos projetos desenvolvidos e na redução do tempo para seu desenvolvimento. Os conversores de protocolos sempre foram desenvolvidos através de técnicas análise, projeto e programação estruturada. Este trabalho tem por objetivo estudar as características da análise, projeto e programação orientados a objetos e sua aplicabilidade ao desenvolvimento de um conversor de protocolos de comunicação para a área de automação elétrica. Serão objetos deste estudo dois protocolos de comunicação com diferentes características de implementação sendo estes o protocolo IEC 60870-5-101 e o protocolo Modbus. O desenvolvimento obedece à sintaxe e semântica dos diagramas da UML (Unified Modeling Language), utilizando a ferramenta Rational Rose. / The evolution of the development software techniques has brought improvements in the quality of the developed projects and in the reduction of the time for its development. The converters of protocols had been always developed through techniques analysis, project and structuralized programming. This work has for objective to study the characteristics of the object-oriented analysis, project and programming and its applicability to the development of a converter of protocols of communication for the area of electric automation. Two protocols of communication with different characteristics of implementation will be objects of this study being the protocol IEC the 60870-5-101 and Modbus protocol. The development obeys the syntax and semantics of the diagrams of UML (Unified Modeling Language), using the Rational Rose tool.
1410

Determinação do coeficiente piroelétrico de polímeros utilizando a técnica de temperatura oscilante no tempo / Pyroelectric coefficient determination of polymers using sinusoidal temperature variation technique

Miranda Filho, Manoel Gregorio de 12 November 1999 (has links)
O objetivo deste trabalho foi implementar um sistema para a determinação do coeficiente piroelétrico em materiais poliméricos. O método consiste em variar a temperatura da amostra de forma senoidal e medir a corrente em função do tempo. Através do sinal da corrente elétrica e da sua diferença de fase com a temperatura, separa-se a corrente elétrica de origem piroelétrica, a partir da qual se determina o coeficiente piroelétrico. Apresenta-se a caracterização do sistema abrangendo aspectos como o intervalo de temperatura das medidas e amplitude e freqüência da oscilação da temperatura. O método foi empregado para realizar medidas exploratórias com o polímero ferroelétrico poli(fluoreto de vinilideno), PVDF, polarizado pela aplicação de uma rampa de tensão, e com o polímero poli(metacrilato de metila), PMMA, com corante polar, polarizado com o triodo de corona. Nas medidas foram variados os parâmetros do processo de polarização elétrica tais como o campo elétrico máximo e a temperatura / An experimental setup to measure the pyroelectric coefficient of polymers was implemented. The method is based on the measurement of the electric current generated by the sample when its temperature was set to oscillate sinusoidally. Using the measured current and its phase difference related with the temperature thepyroelectric current was obtained, from that the pyroelectric coefficient was determined. It is shown the characterization of the experimental system such as the temperature amplitude and frequency interval of operation. The method was applied in exploratory measurements employing the ferroelectric polymer poly(vynilidene fIuoride), PVDF, poled by a ramp voltage, and the poly(methyl metacrylate), PMMA, having a polar dye, poled with the carona triode. Measurements were performed far different poling conditions such as the maximum applied field and temperature

Page generated in 0.0383 seconds