• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 34
  • 7
  • 1
  • 1
  • Tagged with
  • 57
  • 27
  • 17
  • 13
  • 12
  • 11
  • 10
  • 9
  • 9
  • 9
  • 9
  • 9
  • 8
  • 8
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Desenvolvimento e caracterização de dispositivo eletroquímico baseado em nanopartículas de cobre suportadas sobre grafeno para para detecção do herbicida glifosato

Setznagl, Sarah January 2018 (has links)
Orientador: Ivana Cesarino / Resumo: O glifosato é o agrotóxico mais usado no mundo e atualmente é detectado em amostras por métodos cromatográficos. A fim de contribuir com as limitações desta técnica, este trabalho apresenta uma nova alternativa para a análise deste pesticida através de uma técnica eletroanalítica. Trata-se de uma molécula não eletroativa e que, portanto, não é detectada voltametricamente com sua estrutura básica, seja na forma molecular ou iônica. No entanto, é possível detectá-la de forma indireta devido à sua propriedade de formar complexos com íons cúpricos. Um sensor foi desenvolvido para a detecção de glifosato, usando a técnica de voltametria de pulso diferencial (DPV) e um eletrodo de carbono vítreo (GC) modificado com um compósito de óxido de grafeno reduzido (rGO) e nanopartículas de cobre (CuNPs), sintetizado por método químico. O comportamento eletroquímico dos eletrodos GC/rGO-CuNPs foi caracterizado por voltametria cíclica (CV) em solução tampão fosfato (PBS) pH 7,4no intervalo de -0,3 a +0,2 V vs. Ag/AgCl/KCl (3,0 mol L-1), com velocidade de varredura de 50mV s-1. Foram observados processos de oxidação em 30 mV e redução em -180 mV, que comprovam que rGO foi modificado com as CuNPs.Por DPV, a diminuição na corrente de pico anódica do cobre em presença de glifosato, atribuída formação do complexo Cu(II)-glifosato, foi usada para quantificar o analito em amostras. Assim, o eletrodo desenvolvido foi avaliado e otimizado na detecção glifosato por DPV, e os melhores resultados obtido... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Glyphosate is the most widely used pesticide in the world and is currently detected in samples by chromatographic methods. In order to contribute to the limitations of this technique, this work presents a new alternative for the analysis of this pesticide through an electroanalytical technique. It is a non-electroactive molecule and therefore is not detected voltammetrically with its basic structure, either in molecular or ionic form. However, it is possible to detect it indirectly because of its property of forming complexes with cupric ions. A sensor was developed for the detection of glyphosate using the differential pulse voltammetry (DPV) technique and a modified graphene oxide (GC) electrode with reduced graphene oxide (rGO) and copper nanoparticles (CuNPs), synthesized by chemical method. The electrochemical behavior of the GC / rGO-CuNPs electrodes was characterized by cyclic voltammetry (CV) in phosphate buffered saline (PBS) pH 7.4 in the range of -0.3 to +0.2 V vs. Ag / AgCl / KCl (3.0 mol L-1), with a scanning speed of 50mV s-1. Oxidation processes were observed at 30 mV and reduction at -180 mV, which proved that rGO was modified with CuNPs. By DPV, the decrease in the anodic peak current of copper in the presence of glyphosate, attributed the formation of Cu (II) -glyphosate, was used to quantify the analyte in samples. Thus, the electrode developed was evaluated and optimized for glyphosate detection by DPV, and the best results were obtained in the following c... (Complete abstract click electronic access below) / Mestre
22

Desenvolvimento de método de determinação de glicerol livre em biodiesel utilizando a técnica de varredura sucessiva de potencial

Lourenço, Leandro Maranghetti [UNESP] 15 July 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:06Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-07-15Bitstream added on 2014-06-13T19:05:17Z : No. of bitstreams: 1 lourenco_lm_dr_araiq.pdf: 1689549 bytes, checksum: 7855920479cda20853107254ee14614c (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / constituído por uma mistura de ésteres metílicos e/ou etílicos de ácidos graxos. É comumente obtido por meio da reação de transesterificação de triacilgliceróis, produzindo como subproduto o glicerol, considerado seu principal contaminante. A presença deste contaminante no biodiesel traz diversos inconvenientes que podem ocasionar baixo desempenho nos atuais motores e deterioração nos tanques de combustível. A determinação da qualidade do biodiesel é, portanto, de grande importância para aceitação e comercialização do biodiesel e de suas misturas com o diesel. Desta forma, o presente trabalho descreve o desenvolvimento de um método eletroanalítico rápido, sensível, barato e capaz de quantificar o glicerol livre em amostras de biodiesel tipo B100. Parâmetros como acidez, velocidade de varredura e número de ciclos sucessivos voltamétricos foram otimizados, possibilitando grande precisão e estabilidade ao método eletroanalítico desenvolvido. Um rápido método de extração foi desenvolvido, onde uma massa de 2 a 4 g de biodiesel (com precisão de 0,1 mg) é pesada em tubos de ensaio com posterior adição de 6 mL de água, seguida de etapas de agitação, separação de fase aquosa, purificação em cartuchos do tipo C18 e rotoevaporação. As condições eletroanalíticas empregadas foram: concentração analítica de ácido perclórico de 100 mmol L-1, velocidade de varredura de 100 mV s-1 e realização de 20 ciclos sucessivos voltamétricos entre os potenciais de -140 e 1300 mV versus Ag/AgCl(sat). O método eletroanalítico desenvolvido mostra-se promissor, com um limite de detecção estimado de 2,3 mg L-1 (2,5 × 10-2 mmol L-1) para o glicerol. Foi obtida uma excelente linearidade entre 15 e 150 mg L-1 (0,16 e 1,6 mmol L-1) em meio aquoso, que corresponde a uma faixa de trabalho de 56 a 560 mg kg-1 (glicerol:biodiesel) quando uma massa de 2 g de biodiesel... / Biodiesel is a renewable, biodegradable alternative to diesel consisting of a mixture of methyl and/or ethyl esters of fatty acids. It is usually produced from the transesterification reaction of triacylglycerols, and a by-product of this reaction is glycerol, the main contaminant of biodiesel. The presence of glycerol in biodiesel is inconvenient for a number of reasons: it may be responsible for the low performance of engines and deterioration of fuel tanks. Therefore, biodiesel quality control is of utmost importance for the commercialization of this fuel and its mixtures with diesel. In this sense, the present work describes the design of a fast, sensitive, inexpensive electroanalytical method for determination of free glycerol in biodiesel samples of the B100 type. Parameters such as acidity, scan rate, and number of successive voltammetric cycles were optimized, conferring large precision and stability to the designed electroanalytical method. A fast extraction method was also developed, in which 2 to 4 g of biodiesel (with a precision of 0.1 mg) is weighed in test tubes, with further addition of 6 mL of water, followed by stirring steps, aqueous phase separation, purification in cartridges of the C18 type, and rotaevaporation. The eletroanalytical conditions employed in the analysis were: perchloric acid analytical concentration of 100 mmol L-1, scan rate equal to 100 mV s-1, and the performance of 20 successive voltammetric cycles between -140 and 1300 mV versus Ag/AgCl(sat). The designed eletroanalytical method proved to be a promising analytical tool, with an estimated detection limit of 2.3 mg L-1 (2.5 × 10-2 mmol L-1) for glycerol. An excellent linearity was obtained between 15 and 150 mg L-1 (0.16 and 1.6 mmol L-1) in aqueous medium, which corresponds to a work range from 56 to 560 mg kg-1 (glycerol:biodiesel) when a mass of biodiesel of 2 g is employed in the extraction... (Complete abstract click electronic access below)
23

Eletrodos modificados por óxido de tungstênio: Métodos de preparação e aplicações analíticas / Modified Electrodes with Tungsten Oxide: Preparation Methods and Analytic Applications

José Roberto Caetano da Rocha 23 January 2006 (has links)
Neste trabalho são apresentados resultados da eletrodeposição de MoOx e de WOx em eletrodos de carbono vítreo e em eletrodos de ouro. A estabilidade de filmes de WOx foi investigada em diferentes valores de pH utilizando voltametria cíclica e microbalança eletroquímica de cristal de quartzo e observou-se que estes filmes são estáveis em soluções com valores de pH inferiores a 3. O processo eletrocatalítico envolvendo a redução de IO3- em superfícies recobertas com WOx foi comparado com aquele observado em eletrodo modificado com MoOx, observando-se as vantagens deste processo em superfícies modificadas com WOx. Discutiram-se ainda os resultados obtidos do processo da oxidação de óxido nítrico na superfície eletródica polida e modificada com WOx. Também são apresentados resultados de estudos comparativos sobre a redução do IO3-, BrO3- e ClO3- na superfície modificada, concluindo-se que no caso do IO3- obtêm-se maiores valores de corrente devido à maior polarizabilidade do átomo de iodo em relação aos outros dois halogênios. Estudos envolvendo a permeabilidade de íons IO3- e Fe(CN)63- em filmes de WOx foram realizados por voltametria com eletrodos rotativos percebendo-se que filmes mais espessos apresentam pouca permeabilidade. Eletrodos recobertos por filmes de WOx foram utilizados como sensores amperométricos para iodato. Para tanto, desenvolveu-se método em fluxo para IO3- em uma faixa de concentração de 5 a 5000 mmol/L, com limite de detecção estimado em 210 nmol/L. A repetibilidade do método para 41 injeções de solução 80 mmol/L de IO3- foi de 98,3 %. Também foram realizados ensaios para determinar o analito em amostras de sal de cozinha e os dados obtidos foram concordantes com os resultados oriundos do uso de método oficial. / Thin films of non-stoichiometric tungsten oxides have been deposited onto glassy carbon surfaces by electrodeposition from acidic W (VI) solutions. At these modified surfaces, rotating disc electrode voltammetric experiments indicated that iodate is electrocatalytically reduced in a mass-transport controlled process. The influence of the film thickness on the response to iodate was investigated and the results suggested a reaction occurring at the film/solution interface. The modified electrode was employed successfully as an amperometric sensor for iodate in a flow injection apparatus. The linear response of the developed method is extended from a 5 mmol L-1 to 5 mmol L-1 iodate with a limit of detection (signal-to-noise = 3) of 210 nmol L-1. The repeatability of the method for 41 injections of an 80 mmol L-1 iodate solution was 98,3 % and the throughput was determined as 123 injections h-1. Interference from other oxidant anions such as nitrate and nitrite was not noticeable, whereas bromate and chlorate interfere at slight levels. The method was used in the determination of the iodate content in commercial salt samples.
24

Correlating Redox-Labeled Nucleic Acid Structure with Electrochemical Signaling

Sykes, Kiana January 2021 (has links)
No description available.
25

Desenvolvimento de sensores e de métodos analíticos para determinação de compostos de interesse farmacêutico / Development of sensors and analytical methods for determination of compounds of pharmaceutical relevance

Silva, Iranaldo Santos da 11 October 2013 (has links)
A crescente demanda por produtos farmacêuticos tem como consequência a necessidade de elaboração de novos procedimentos analíticos que, via de regra, apresentem características como: elevada frequência analítica, simplicidade, ausência de substâncias altamente tóxicas, e com baixo custo para o controle de qualidade dos fármacos lançados no mercado. Neste trabalho descreve-se o desenvolvimento de procedimentos para determinação de N-acetilcisteína (NAC), nimesulida (NMS), trimetoprima (TMP) e sulfametoxazol (SMX) em formulações farmacêuticas usando técnicas eletroanalíticas e métodos de separação. Na determinação da NAC foi usado um eletrodo de grafite pirolítico modificado com ftalocianina de cobalto (CoPc) em 0,1 mol L-1 de NaOH. Este sensor mostrou intensa catálise para NAC produzindo um aumento na corrente anódica de cerca de 700 vezes quando comparado com o eletrodo limpo. Um procedimento em FIA foi proposto usando este sensor, e a curva analítica foi linear no intervalo 5,0 × 10-5 a 1,0 × 10-3 mol L-1, com coeficiente de correlação maior que 0,999. O DPR de 1,1% (n = 13) foi obtido para uma solução contendo 5,0 × 10-4 mol L-1 de NAC. Além disso o método apresentou LD e LQ de 9,0 ×10-7 mol L-1 e 3,0 × 10-6 mol L-1, respectivamente. A determinação eletroanalítica de NMS foi conduzida em solução de 1,0 mol L-1 de NaOH usando eletrodo de carbono vítreo, meio em que não ocorre envenenamento da superfície do eletrodo. Desse modo, um método eletroanalítico usando voltametria de onda quadrada foi elaborado para análise de NMS. Nas condições ótimas de análise o método apresentou uma faixa linear no intervalo de 4,3 × 10-5 a 4,2 × 10-4 mol L-1, com limite de detecção de 3,2 × 10-6 mol L-1. A precisão do método foi avaliada em um mesmo dia de análise por sucessivas medidas voltamétricas (n = 10) em solução de hidróxido de sódio 1,0 mol L-1 contendo 1,0 × 10-4 mol L-1 de NMS, sem a necessidade de renovação da superfície do eletrodo. Os resultados para esta série de medidas foram avaliados e o DPR calculado foi somente 1,2%, indicando que nessas condições o eletrodo apresentou uma resposta estável além de não sofrer qualquer efeito de envenenamento. Para a determinação simultânea de TMP e SMX foi desenvolvido um método analítico empregando eletroforese capilar com detecção condutométrica sem contato (C4D). Usando uma solução 10 mmol L-1 lítio-fosfato (pH 7,1 ) como tampão de corrida, a faixa linear de trabalho obtida para ambos os analitos foi de 12,5 a 200 × 10-6 mol L-1 com R > 0,999. Nas condições de análise foram obtidos LDs de 1,1 × 10-6 mol L-1 para a TMP, e 3,3 × 10-6 mol L-1 para o SMX com um tempo total de análise de 2,6 minutos. / The growing demand for pharmaceutical products has created need for developing new analytical procedures that, as a rule, exhibit characteristics like, high sampling rate, simplicity, absence of highly toxic substances, and low cost for quality control of drugs launched in market. In this work, electroanalytical and capillary electrophoresis methods for determination of N-acetylcysteine (NAC), nimesulide (NMS), trimethoprim (TMP) and sulfamethoxazole (SMX) in pharmaceutical formulations were proposed. For NAC determinations a pyrolytic graphite electrode modified with CoPc in 0.1 mol L-1 NaOH was used. This new sensor showed to be catalytic for this compound producing an anodic current increase of 700 times when compared with bare electrode. A FIA procedure was proposed using this new sensor, and the method showed a linear response in a range of 5.0 × 10-5 to 1.0 × 10-3 mol L-1 with correlation coefficient better than 0.999. RSD of 1.1% (n = 13) was obtained for a solution containing 5.0 × 10-4 mol L-1 NAC. Furthermore the method presented DL and QL of 9.0 × 10-7 mol L-1 and 3.0 × 10-6 mol L-1, respectively. NMS electroanalytical determination was conducted in a 1.0 mol L-1 NaOH solution using a glassy carbon electrode. In strongly alkaline medium it was verified that NMS does not produce poisoning of the electrode surface. Thus an electroanalytical method using square wave voltammetry was proposed for analysis of NMS. In the optimal analysis conditions proposed method showed a linear response in a range of 4.3 × 10-5 to 4.2 × 10-4 mol L-1, with detection limit of 3.2 × 10-6 mol L-1. Accuracy of the method was evaluated on the same day by successive voltammetric measurements (n = 10) in a 1.0 mol L-1 sodium hydroxide solution containing 1.0 × 10-4 mol L-1 of NMS without the needing to renew electrode surface. Results for this series of measures were calculated and standard deviation was of only 1.2%, suggesting that in these conditions the electrode showed a stable response in addition to suffer no poisoning effects. For simultaneous determination of TMP and SMX an analytical method using capillary electrophoresis with contactless conductivity detection (C4D) was developed. Using a 10 mmol L-1 lithium-phosphate (pH 7.1) solution as running buffer, a linear response range for both analytes was obtained ranging through 12.5 to 200 × 10-6 mol L-1 with R> 0.999. Under these analysis conditions, DL of 1.1 × 10-6 mol L-1 for TMP, and 3.3 × 10-6 mol L-1 for SMX were obtained, with a total analysis time of only 2.6 minutes.
26

Desenvolvimento de carbonos mesoporosos ordenados para aplicação em sensores eletroquímicos / Development of ordered mesoporous carbon for electrochemical sensors application

Maluta, Jaqueline Ruiz 11 August 2017 (has links)
O desenvolvimento de novos materiais para a aplicação em eletroanalítica, uma atividade extremamente atraente, visa produzir compostos com condutividade elétrica alta, estabilidade mecânica e química e grandes áreas superficiais. Assim, nesta tese foram desenvolvidos Carbonos Mesoporosos Ordenados, um tipo de material carbônico recentemente explorado para diversas aplicações devido às suas propriedades específicas e facilmente manipuláveis. A produção inicia-se com a síntese da sílica mesoporosa utilizada como template, seguida pela impregnação por molhamento incipiente utilizando moléculas que são concomitantemente, fontes de carbono e de um heteroátomo (S, N ou O). Após a polimerização e carbonização em atmosfera não-oxidante, removeu-se o template de sílica, obtendo-se um material altamente organizado de estrutura mesoporosa, caracterizado pelas análises de BET, MET e DRX em ângulos baixos. Os materiais sintetizados apresentaram área superficial grande e acessível, indicadas pelas as análises de BET, o que ofereceu uma alta eficiência de pré-concentração de analitos. A fim de garantir um carbono com características grafíticas e boa condutividade, partiu-se de fontes carbônicas aromáticas e utilizou-se o óxido de ferro como catalisador da polimerização. Com isso, obteve-se materiais com carácter grafítico, mostrado pelas análises de DRX e Raman, com excelentes propriedades elétricas e transferência eletrônica mais rápida, mostrado pelas análises eletroquímicas (VC e EIE) garantindo um material com excelente atividade eletrocatalítica. Os três diferentes tipos de dopagem geraram três materiais distintos, que diferem não apenas na composição química, mas também nas propriedades físicas, elétricas e em sua resposta eletroanalítica. Os materiais sintetizados foram aplicados na detecção do cloranfenicol, um antibiótico com propriedades antibacterianas e farmacocinéticas excelentes, porém proibido em produtos destinados ao consumo humano. A metodologia desenvolvida apresentou boa sensibilidade e limites de detecção e quantificação, além da capacidade de analisar diretamente leite em pó, sem a necessidade de etapas trabalhosas de preparo de amostra. / The development of new materials for electroanalitycal application aims to produce materials with high electric conductivity, mechanical and chemical stability, and high surface areas. So, in this thesis, it was developed Ordered Mesoporous Carbon, a carbonic material recently explored in several applications due its specific plasticity properties. The production starts with the mesoporous silica synthesis. It is used as template, followed by the incipient wetness impregnation using molecules that are both a carbon source and heteroatom precursor (S, N or O). After the polymerization and the non-oxidant atmosphere carbonization, the template was removed, what yielded a highy ordered mesoporous structure, demonstrated by BET, TEM and low-angle XRD analysis. The synthetized materials showed high and accessible surface area, demonstrated by BET, which allowed high pre-concentration efficiency with a fast diffusion process. In order to get a graphitic carbon with good conductivity, it was used aromatic carbon precursors and iron as polymerization catalyst. Consequently, a material with graphitic character was getting, as we can see at XRD and Raman, with excellent electric properties and faster electronic transference, showed by electrochemical analysis (CV and EIS), leading to a material with excellent electrocatalytic activity. The three different doping types leading to three distinct materials, which differ not only at chemical composition, but also at physical, electrics and electroanalytical properties. The materials was applied at chloramphenicol detection, an antibiotic with excellent antibacterial and pharmacokinetics properties. However, it is forbidden in edible products. The developed methodology has good sensibility, and limits of detection and quantification. In addition, was possible to analyze powder milk directly, without any other timing consuming procedure of sample preparing.
27

Investigação do comportamento eletroquímico do inseticida fipronil e desenvolvimento de metodologia eletroanalítica / Investigation of the electrochemical behavior of the insecticide fipronil and development of electroanalytical methodology

Amaral, Raquel Bonatto do 25 May 2012 (has links)
Essa tese de doutorado apresenta o estudo eletroquímico da oxidação do inseticida fipronil bem como o desenvolvimento de metodologias analíticas para a determinação deste composto em amostras de águas naturais. Os experimentos foram realizados sobre os eletrodos de compósito grafite-poliuretana (GPU) e carbono vítreo modificado com nanotubos de carbono de paredes múltiplas (GC-MWCNTs) utilizando a Voltametria de Onda Quadrada (SWV). A Voltametria Cíclica (CV) foi utilizada para diagnosticar o grau de reversibilidade da reação de oxidação do inseticida assim como a natureza do transporte do material eletroativo para a superfície dos eletrodos. Os resultados dos estudos da oxidação eletroquímica do fipronil utilizando o eletrodo de GPU mostraram que a oxidação do fipronil apresenta um em 0,70 V (vs. EAg/AgCl) e ocorre de forma totalmente irreversível e controlada por adsorção das espécies na superfície do eletrodo. Foram obtidas curvas analíticas para o fipronil no intervalo de 2,0 a 14,0 x 10-5 mol L-1, resultando um limite de detecção (LD) de 139 µg L-1 e Limite de Quantificação (LQ) de 480 µg L-1. Para a oxidação do fipronil no eletrodo GC-MWCNTs os resultados mostraram que a oxidação do fipronil apresenta apenas um pico em 0,50 V (vs. EAg/AgCl) e ocorre de forma totalmente irreversível e controlado por difusão a adsorção das espécies na superfície do eletrodo. Os LD e LQ obtidos foram de 26 µg L-1 e 147 µg L-1, respectivamente. O estudo por eletrólise a potencial controlado revelou que a oxidação do inseticida fipronil envolve a participação de um elétron. A metodologia desenvolvida para ambos os eletrodos foi aplicada em amostras de águas naturais, testes de recuperação foram realizados mostrando eficiência de recuperação 96,0% para o eletrodo de GPU e de 94,6% para o eletrodo de GC-MWCNTs. / In this thesis a study of the electrochemical oxidation of the insecticide fipronil and the development of analytical methodologies for the determination of this compound in natural water samples is presented. The experiments were performed at graphite-polyurethane composite electrodes (GPU) and a glassy carbon electrode modified with multi-walled carbon nanotubes (MWCNTs-GC). The electrodes were caracterized using square wave voltammetry (SWV). Cyclic voltammetry (CV) was used to diagnose the degree of reversibility of the oxidation reaction of the insecticide as well as the nature of the transport of the electroactive material to the surface of the electrodes. The electrochemical oxidation of fipronil studies using the GPU electrode showed that fipronil oxidation presents a peak at 0.70 V (vs. EAg/AgCl) which is totally irreversible and controlled by adsorption of species on the electrode surface. Analytical curves were obtained for fipronil in the range 2.0 to 14 x 10-5 mol L-1, with a detection limit (LD) of 139 µg L-1 and a quantification limit (LQ) of 480 µg L-1. For the oxidation of fipronil in the GC-MWCNTs electrode the results showed that fipronil oxidation presents a peak at 0.50 V (vs. EAg/AgCl) which is totally irreversible and diffusion controlled the adsorption of species on the electrode surface. The LD and LQ were obtained 26 µg L-1 and 147 µg L-1, respectively. The study by controlled potential electrolysis showed that oxidation of the insecticide fipronil involves the participation of one electron. The methodology developed for both electrodes was applied to natural water samples, recovery tests were performed showing recovery efficiency of 96.0% for the GPU electrode and 94.6% for MWCNTs-GC electrode.
28

Desenvolvimento de sensores e de métodos analíticos para determinação de compostos de interesse farmacêutico / Development of sensors and analytical methods for determination of compounds of pharmaceutical relevance

Iranaldo Santos da Silva 11 October 2013 (has links)
A crescente demanda por produtos farmacêuticos tem como consequência a necessidade de elaboração de novos procedimentos analíticos que, via de regra, apresentem características como: elevada frequência analítica, simplicidade, ausência de substâncias altamente tóxicas, e com baixo custo para o controle de qualidade dos fármacos lançados no mercado. Neste trabalho descreve-se o desenvolvimento de procedimentos para determinação de N-acetilcisteína (NAC), nimesulida (NMS), trimetoprima (TMP) e sulfametoxazol (SMX) em formulações farmacêuticas usando técnicas eletroanalíticas e métodos de separação. Na determinação da NAC foi usado um eletrodo de grafite pirolítico modificado com ftalocianina de cobalto (CoPc) em 0,1 mol L-1 de NaOH. Este sensor mostrou intensa catálise para NAC produzindo um aumento na corrente anódica de cerca de 700 vezes quando comparado com o eletrodo limpo. Um procedimento em FIA foi proposto usando este sensor, e a curva analítica foi linear no intervalo 5,0 × 10-5 a 1,0 × 10-3 mol L-1, com coeficiente de correlação maior que 0,999. O DPR de 1,1% (n = 13) foi obtido para uma solução contendo 5,0 × 10-4 mol L-1 de NAC. Além disso o método apresentou LD e LQ de 9,0 ×10-7 mol L-1 e 3,0 × 10-6 mol L-1, respectivamente. A determinação eletroanalítica de NMS foi conduzida em solução de 1,0 mol L-1 de NaOH usando eletrodo de carbono vítreo, meio em que não ocorre envenenamento da superfície do eletrodo. Desse modo, um método eletroanalítico usando voltametria de onda quadrada foi elaborado para análise de NMS. Nas condições ótimas de análise o método apresentou uma faixa linear no intervalo de 4,3 × 10-5 a 4,2 × 10-4 mol L-1, com limite de detecção de 3,2 × 10-6 mol L-1. A precisão do método foi avaliada em um mesmo dia de análise por sucessivas medidas voltamétricas (n = 10) em solução de hidróxido de sódio 1,0 mol L-1 contendo 1,0 × 10-4 mol L-1 de NMS, sem a necessidade de renovação da superfície do eletrodo. Os resultados para esta série de medidas foram avaliados e o DPR calculado foi somente 1,2%, indicando que nessas condições o eletrodo apresentou uma resposta estável além de não sofrer qualquer efeito de envenenamento. Para a determinação simultânea de TMP e SMX foi desenvolvido um método analítico empregando eletroforese capilar com detecção condutométrica sem contato (C4D). Usando uma solução 10 mmol L-1 lítio-fosfato (pH 7,1 ) como tampão de corrida, a faixa linear de trabalho obtida para ambos os analitos foi de 12,5 a 200 × 10-6 mol L-1 com R > 0,999. Nas condições de análise foram obtidos LDs de 1,1 × 10-6 mol L-1 para a TMP, e 3,3 × 10-6 mol L-1 para o SMX com um tempo total de análise de 2,6 minutos. / The growing demand for pharmaceutical products has created need for developing new analytical procedures that, as a rule, exhibit characteristics like, high sampling rate, simplicity, absence of highly toxic substances, and low cost for quality control of drugs launched in market. In this work, electroanalytical and capillary electrophoresis methods for determination of N-acetylcysteine (NAC), nimesulide (NMS), trimethoprim (TMP) and sulfamethoxazole (SMX) in pharmaceutical formulations were proposed. For NAC determinations a pyrolytic graphite electrode modified with CoPc in 0.1 mol L-1 NaOH was used. This new sensor showed to be catalytic for this compound producing an anodic current increase of 700 times when compared with bare electrode. A FIA procedure was proposed using this new sensor, and the method showed a linear response in a range of 5.0 × 10-5 to 1.0 × 10-3 mol L-1 with correlation coefficient better than 0.999. RSD of 1.1% (n = 13) was obtained for a solution containing 5.0 × 10-4 mol L-1 NAC. Furthermore the method presented DL and QL of 9.0 × 10-7 mol L-1 and 3.0 × 10-6 mol L-1, respectively. NMS electroanalytical determination was conducted in a 1.0 mol L-1 NaOH solution using a glassy carbon electrode. In strongly alkaline medium it was verified that NMS does not produce poisoning of the electrode surface. Thus an electroanalytical method using square wave voltammetry was proposed for analysis of NMS. In the optimal analysis conditions proposed method showed a linear response in a range of 4.3 × 10-5 to 4.2 × 10-4 mol L-1, with detection limit of 3.2 × 10-6 mol L-1. Accuracy of the method was evaluated on the same day by successive voltammetric measurements (n = 10) in a 1.0 mol L-1 sodium hydroxide solution containing 1.0 × 10-4 mol L-1 of NMS without the needing to renew electrode surface. Results for this series of measures were calculated and standard deviation was of only 1.2%, suggesting that in these conditions the electrode showed a stable response in addition to suffer no poisoning effects. For simultaneous determination of TMP and SMX an analytical method using capillary electrophoresis with contactless conductivity detection (C4D) was developed. Using a 10 mmol L-1 lithium-phosphate (pH 7.1) solution as running buffer, a linear response range for both analytes was obtained ranging through 12.5 to 200 × 10-6 mol L-1 with R> 0.999. Under these analysis conditions, DL of 1.1 × 10-6 mol L-1 for TMP, and 3.3 × 10-6 mol L-1 for SMX were obtained, with a total analysis time of only 2.6 minutes.
29

Desenvolvimento de carbonos mesoporosos ordenados para aplicação em sensores eletroquímicos / Development of ordered mesoporous carbon for electrochemical sensors application

Jaqueline Ruiz Maluta 11 August 2017 (has links)
O desenvolvimento de novos materiais para a aplicação em eletroanalítica, uma atividade extremamente atraente, visa produzir compostos com condutividade elétrica alta, estabilidade mecânica e química e grandes áreas superficiais. Assim, nesta tese foram desenvolvidos Carbonos Mesoporosos Ordenados, um tipo de material carbônico recentemente explorado para diversas aplicações devido às suas propriedades específicas e facilmente manipuláveis. A produção inicia-se com a síntese da sílica mesoporosa utilizada como template, seguida pela impregnação por molhamento incipiente utilizando moléculas que são concomitantemente, fontes de carbono e de um heteroátomo (S, N ou O). Após a polimerização e carbonização em atmosfera não-oxidante, removeu-se o template de sílica, obtendo-se um material altamente organizado de estrutura mesoporosa, caracterizado pelas análises de BET, MET e DRX em ângulos baixos. Os materiais sintetizados apresentaram área superficial grande e acessível, indicadas pelas as análises de BET, o que ofereceu uma alta eficiência de pré-concentração de analitos. A fim de garantir um carbono com características grafíticas e boa condutividade, partiu-se de fontes carbônicas aromáticas e utilizou-se o óxido de ferro como catalisador da polimerização. Com isso, obteve-se materiais com carácter grafítico, mostrado pelas análises de DRX e Raman, com excelentes propriedades elétricas e transferência eletrônica mais rápida, mostrado pelas análises eletroquímicas (VC e EIE) garantindo um material com excelente atividade eletrocatalítica. Os três diferentes tipos de dopagem geraram três materiais distintos, que diferem não apenas na composição química, mas também nas propriedades físicas, elétricas e em sua resposta eletroanalítica. Os materiais sintetizados foram aplicados na detecção do cloranfenicol, um antibiótico com propriedades antibacterianas e farmacocinéticas excelentes, porém proibido em produtos destinados ao consumo humano. A metodologia desenvolvida apresentou boa sensibilidade e limites de detecção e quantificação, além da capacidade de analisar diretamente leite em pó, sem a necessidade de etapas trabalhosas de preparo de amostra. / The development of new materials for electroanalitycal application aims to produce materials with high electric conductivity, mechanical and chemical stability, and high surface areas. So, in this thesis, it was developed Ordered Mesoporous Carbon, a carbonic material recently explored in several applications due its specific plasticity properties. The production starts with the mesoporous silica synthesis. It is used as template, followed by the incipient wetness impregnation using molecules that are both a carbon source and heteroatom precursor (S, N or O). After the polymerization and the non-oxidant atmosphere carbonization, the template was removed, what yielded a highy ordered mesoporous structure, demonstrated by BET, TEM and low-angle XRD analysis. The synthetized materials showed high and accessible surface area, demonstrated by BET, which allowed high pre-concentration efficiency with a fast diffusion process. In order to get a graphitic carbon with good conductivity, it was used aromatic carbon precursors and iron as polymerization catalyst. Consequently, a material with graphitic character was getting, as we can see at XRD and Raman, with excellent electric properties and faster electronic transference, showed by electrochemical analysis (CV and EIS), leading to a material with excellent electrocatalytic activity. The three different doping types leading to three distinct materials, which differ not only at chemical composition, but also at physical, electrics and electroanalytical properties. The materials was applied at chloramphenicol detection, an antibiotic with excellent antibacterial and pharmacokinetics properties. However, it is forbidden in edible products. The developed methodology has good sensibility, and limits of detection and quantification. In addition, was possible to analyze powder milk directly, without any other timing consuming procedure of sample preparing.
30

Investigação do comportamento eletroquímico do inseticida fipronil e desenvolvimento de metodologia eletroanalítica / Investigation of the electrochemical behavior of the insecticide fipronil and development of electroanalytical methodology

Raquel Bonatto do Amaral 25 May 2012 (has links)
Essa tese de doutorado apresenta o estudo eletroquímico da oxidação do inseticida fipronil bem como o desenvolvimento de metodologias analíticas para a determinação deste composto em amostras de águas naturais. Os experimentos foram realizados sobre os eletrodos de compósito grafite-poliuretana (GPU) e carbono vítreo modificado com nanotubos de carbono de paredes múltiplas (GC-MWCNTs) utilizando a Voltametria de Onda Quadrada (SWV). A Voltametria Cíclica (CV) foi utilizada para diagnosticar o grau de reversibilidade da reação de oxidação do inseticida assim como a natureza do transporte do material eletroativo para a superfície dos eletrodos. Os resultados dos estudos da oxidação eletroquímica do fipronil utilizando o eletrodo de GPU mostraram que a oxidação do fipronil apresenta um em 0,70 V (vs. EAg/AgCl) e ocorre de forma totalmente irreversível e controlada por adsorção das espécies na superfície do eletrodo. Foram obtidas curvas analíticas para o fipronil no intervalo de 2,0 a 14,0 x 10-5 mol L-1, resultando um limite de detecção (LD) de 139 µg L-1 e Limite de Quantificação (LQ) de 480 µg L-1. Para a oxidação do fipronil no eletrodo GC-MWCNTs os resultados mostraram que a oxidação do fipronil apresenta apenas um pico em 0,50 V (vs. EAg/AgCl) e ocorre de forma totalmente irreversível e controlado por difusão a adsorção das espécies na superfície do eletrodo. Os LD e LQ obtidos foram de 26 µg L-1 e 147 µg L-1, respectivamente. O estudo por eletrólise a potencial controlado revelou que a oxidação do inseticida fipronil envolve a participação de um elétron. A metodologia desenvolvida para ambos os eletrodos foi aplicada em amostras de águas naturais, testes de recuperação foram realizados mostrando eficiência de recuperação 96,0% para o eletrodo de GPU e de 94,6% para o eletrodo de GC-MWCNTs. / In this thesis a study of the electrochemical oxidation of the insecticide fipronil and the development of analytical methodologies for the determination of this compound in natural water samples is presented. The experiments were performed at graphite-polyurethane composite electrodes (GPU) and a glassy carbon electrode modified with multi-walled carbon nanotubes (MWCNTs-GC). The electrodes were caracterized using square wave voltammetry (SWV). Cyclic voltammetry (CV) was used to diagnose the degree of reversibility of the oxidation reaction of the insecticide as well as the nature of the transport of the electroactive material to the surface of the electrodes. The electrochemical oxidation of fipronil studies using the GPU electrode showed that fipronil oxidation presents a peak at 0.70 V (vs. EAg/AgCl) which is totally irreversible and controlled by adsorption of species on the electrode surface. Analytical curves were obtained for fipronil in the range 2.0 to 14 x 10-5 mol L-1, with a detection limit (LD) of 139 µg L-1 and a quantification limit (LQ) of 480 µg L-1. For the oxidation of fipronil in the GC-MWCNTs electrode the results showed that fipronil oxidation presents a peak at 0.50 V (vs. EAg/AgCl) which is totally irreversible and diffusion controlled the adsorption of species on the electrode surface. The LD and LQ were obtained 26 µg L-1 and 147 µg L-1, respectively. The study by controlled potential electrolysis showed that oxidation of the insecticide fipronil involves the participation of one electron. The methodology developed for both electrodes was applied to natural water samples, recovery tests were performed showing recovery efficiency of 96.0% for the GPU electrode and 94.6% for MWCNTs-GC electrode.

Page generated in 0.4707 seconds