• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 336
  • 117
  • 103
  • 2
  • Tagged with
  • 565
  • 276
  • 253
  • 197
  • 158
  • 149
  • 117
  • 107
  • 72
  • 72
  • 53
  • 50
  • 45
  • 42
  • 42
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
391

Design and optimization of high speed flash analog-to-digital converters in SiGe BiCMOS technologies / Conception et Optimisation de convertisseurs AD à haute vitesse

Ritter, Philipp 10 July 2013 (has links)
Le Convertisseur Analogique Numérique (CAN) est une brique essentielle de la ré- ception et du traitement des données à très haut débit. L’architecture de type "flash" effectue la quantification en comparant simultanément le signal analogique d’entrée à l’ensemble des références du codeur, ce qui en fait, par construction, l’architecture la plus rapide de CAN. Par le passé, cette architecture a démontré des capacités de codage supérieures à 20GS/s dans les conditions de Nyquist. Cependant, cette capac- ité à travailler à très haute vitesse a donné le jour à des réalisations très consommantes (plusieurs Watts) donc peu efficaces énergétiquement. Cette thèse explore différentes approches d’optimisation de l’efficacité énergétique des CAN "flash". Afin de min- imiser la consommation du CAN, il n’y a pas d’Echantillonneur-Bloqueur (EB) en tête du circuit. Les étages d’entrée du codeur sont ainsi exposés à la pleine bande passante du signal, à savoir DC-10GHz. Ceci impose des contraintes très strictes sur la précision temporelle de la détection et de la quantification du signal. L’essentiel de cette thèse est donc concentré sur l’analyse des effets hautes frèquences impactant la conception des éléments frontaux du CAN. La validité et l’efficacité des méthodes présentées sont démontrées par des mesures autour d’un CAN 6 bit 20 GS/s. En em- pruntant les techniques de conception des circuits ultra-rapides et en exploitant le po- tentiel haute-fréquence de la technologie à l’état de l’art SiGe BiCMOS, un circuit complètement analogique a ainsi pu être réalisé. Ce CAN est mono-voie et n’a besoin d’aucune calibration ou correction, ni d’assistance digitale. Avec à peine 1W, ce cir- cuit atteint un record d’efficacité énergétique dans l’état de l’art des CAN rapides non entrelacés. / High speed Analog-to-Digital Converters (ADC) are essential building blocks for the reception and processing in high data rate reception circuits. The flash ADC archi- tecture performs the digitization by comparing the analog input signal to all refer- ence levels of the quantization range simultaneously and is thus the fastest architecture available. In the past the flash architecture has been employed successfully to digitize signals at Nyquist rates beyond 20 GS/s. However the inherent high speed operation has led to power consumptions of several watts and hence to poor energy efficien- cies. This thesis explores approaches to optimize the energy efficiency of flash ADCs. In particular, no dedicated track-and-hold stage is used at the high speed data input. This imposes very stringent requirements on the timing accuracy and level accuracy in the high speed signal distribution to the comparators. The comparators need to ex- hibit a very high speed capability to correctly perform the quantization of the signal against the reference levels. The main focus of this thesis is hence the investigation of design relevant high frequency effects in the analog ADC frontend, such as the bandwidth requirement of overdriven comparators, the data signal distribution over a passive transmission line tree and the dynamic linearity of emitter followers. The correctness and efficacy of the presented methods is demonstrated by measurement results of a 6 bit 20 GS/s Nyquist rate flash ADC fabricated within the context of this work. The demonstrator ADC operates without time interleaving, no calibration or correction whatsoever is needed. By employing design techniques borrowed from high speed analog circuits engineering and by exhausting the high speed potential of a state-of-the-art SiGe BiCMOS production technology, a flash ADC with a record energy efficiency could be realized.
392

Manipulation de molécules organiques sur couches ultra-minces semi-isolantes et plots métalliques pour la fabrication de circuits moléculaires / Manipulation of organic molecules on ultrathin insulating layers and metallic pads for for the fabrication of molecular circuits

Yengui, Mayssa 29 October 2014 (has links)
L’objectif globale de cette thèse est l’étude de la croissance de plots de siliciure de cobalt (CoSi2) individuels combinés à une surface semi-isolante de silicium hydrogénée (Si(100):H) afin de créer un environnement propice à l’interconnexion de molécules fonctionnalisées, prémisse des circuits moléculaires. Cette étude, liée au contexte de l’électronique moléculaire ascendante, est réalisée à l’aide d’un microscope à effet tunnel (STM) à basse température (9 K) sous ultra-vide. Ce travail de thèse débute par l’étude de l’adsorption d’atomes de Co, à basse température (12 K) sur la surface de Si(100)-2x1. Nos investigations nous ont permis d’observer, pour la première fois, des sites d’adsorption à la surface et des sites interstitiels métastables en surface et subsurface. Grâce aux excitations électroniques induites par les électrons tunnels, certains sites d’adsorption ont pu être manipulés sur la surface de Si(100). Cette étude préliminaire est suivie par la croissance de plots de siliciure de cobalt individuels sur le Si(100) dont les propriétés électroniques ont été étudiées à basse température (9 K). Ceci nous a permis d’identifier deux géométries de plot de CoSi2 de tailles nanométriques dont le caractère métallique est démontré et ayant de faibles barrières de Schottky à l’interface métal/semi-conducteur. Dans un second temps, nous avons examiné les propriétés de molécules de Co-TPP individuelles et de leurs interactions avec les surfaces de Si(100) et de Si(100) hydrogénées. Les topographies STM révèlent différentes conformations d’adsorption ayant des propriétés physico-chimiques particulières telles qu’une fonction bistable intramoléculaire, ainsi que des propriétés électroniques surprenantes permettant de sonder la physisorption totale ou partielle de l’adsorbat. Un troisième volet de cette thèse adresse la possibilité d’exploiter les propriétés intrinsèques de la surface de Si(100):H afin de créer des ponts moléculaires grâce au couplage successif de liaisons pendantes créées sur la surface du Si(100):H. Les mesures de spectroscopie tunnel effectuées sur ces structures exhibent des états inoccupés caractéristiques du couplage orbitalaire entre les liaisons pendantes dont l’énergie est fonction de l’orientation de la ligne déshydrogénée sur la surface. Finalement, après avoir vérifié que le processus d’hydrogénation ne perturbe pas le caractère métallique des plots de CoSi2, nous avons pu exploiter nos connaissances acquises lors des chapitres précédents. Ceci nous a permis d’étudier, pour la première fois, le contact entre molécules de Co-TPP et plots métalliques. Grâce aux techniques de manipulation latérale, les molécules de Co-TPP ont pu être déplacées et contactées aux plots métalliques. La spectroscopie tunnel effectuée sur différentes molécules montre, d’une part, qu’en fonction de leur orientation par rapport à l’îlot de CoSi2, la structure électronique de chaque molécule est modifiée de manière spécifique. D’autre part, nous avons observé que la position de la mesure des spectres tunnels influe sur le gap de la molécule associé, révélant probablement une signature du transport électronique entre la molécule et le plot métallique. L’ensemble de ces résultats ouvre de nouvelles perspectives extrêmement riches et prometteuses pour la réalisation de circuits moléculaires planaires comme prototype d’études fondamentales. / For the fabrication of molecular circuitsThe overall objective of this thesis is to study the growth of individual cobalt silicide (CoSi2) dots combined with a semi-insulating hydrogenated silicon surface (Si(100):H) to create a controlled and suitable environment for the interconnection of functionalized molecules, the premises to molecular circuits. This study, related to the context of the bottom-up molecular electronics, is performed using a scanning tunneling microscope (STM) at low temperature (9 K) under ultrahigh vacuum. This thesis begins with the study of the adsorption of Co atoms on the surface of Si (100)-2x1 kept at low temperature (12 K). Our investigations have led us to observe, for the first time, adsorption sites that are either stable or metastable interstitial sites on the surface and/or subsurface. With electronically induced excitations, some of the Co adsorption sites have been modified or manipulated on the Si(100) surface. This preliminary study is followed by the growth of individual cobalt silicide dots on the Si(100) while their properties are investigated at low temperature (9 K). This allowed us to identify two different types of silicide dots of nanometric sizes whose metallic character is demonstrated while low Schottky barriers at the metal/semiconductor interface are identified. In a second step, we examined the properties of individual Co-TPP molecules and their interactions with the Si(100) and hydrogenated Si(100) surfaces. The STM topographies reveal various conformations with specific properties such as an intra-molecular bistable function, as well as surprising electronic properties that allow probing the physisorbed parts of the adsorbate. A third part of this thesis addresses the possibility of exploiting the intrinsic properties of the Si(100):H surface to create molecular bridges through successive coupling of dangling bonds created at the surface of Si(100):H. Tunnel spectroscopy measurements carried out on these structures exhibit unoccupied states orbitals, signature of the coupling between dangling bonds, whose energy depends on the orientation of the dangling bond lines across the hydrogenated surface. Finally, after checking that the hydrogenation process of the Si(100) surface does not disturb the metallic character of the CoSi2 dots, we used our knowledge gained in previous chapters. This allowed us to study, for the first time, the contact between molecules of Co-TPP and metal dots. With lateral manipulation techniques, the Co-TPP molecules have been displaced and contacted to metallic pads. The tunneling spectroscopy performed on different molecules shows, firstly, that depending on their orientation relative to the CoSi2 dot, the electronic structure of each molecule is modified in a specific manner. On the other hand, we observed that the conductance spectrum influences the gap of the associated molecule, indicating a signature of electron transport between the molecule and the metal pad. Taken together, these results open new extremely rich and promising perspectives for the realization of planar molecular circuit as a prototype for fundamental studies.
393

Imagerie, manipulation et contact électronique atome par atome sur la surface Si(100) : H avec le microscope à effet tunnel basse température à 4 pointes / Imaging, manipulation and electronic contact atome per atome on the Si (100) : H surface with the low-temperature 4 probes scanning tunneling microscope

Sordes, Delphine 03 May 2017 (has links)
La construction de circuits électroniques de section atomique est l'un des grands défis de la nanoélectronique ultime. Pour construire un circuit électronique atomique, il faut d'abord mettre au point l'instrument de construction puis choisir la surface-support stabilisant ce circuit. Sur la surface d'Au(111) préparée en ultra vide, nous avons mis en œuvre et stabilisé le tout premier LT-UHV-4 STM. Ce microscope à 4 pointes STM balayant en même temps et indépendamment une même surface a été construit pour le CEMES par la société ScientaOmicron. Sur l'Au(111), nous avons reproduit tous les résultats expérimentaux obtenus sur les meilleurs LT-UHV-STM à une pointe comme la précision en rugosité de 2 pm, les caractéristiques I-V sans moyenne sur un seul atome pendant plusieurs dizaines de minutes et la manipulation atomique suivant les modes de tiré, glissé et poussé d'un seul atome d'or sur la surface. Une fois cette optimisation réalisée, nous avons appliqué notre LT-UHV-4 STM à la surface de Si(100):H, support probable des futurs circuits atomiques électroniques. Le choix de ce support est discuté en détail avant l'enregistrement et l'analyse des images STM. Les échantillons utilisés proviennent, soit du procédé semi-industriel pleine-plaque de silicium mis au point au CEA-LETI, soit de leur préparation in situ se déroulant directement dans la chambre de préparation du LT-UHV-4 STM. Nous avons pris soin de bien interpréter les images STM de la surface Si(100):H afin par exemple de déterminer la position de chaque atome d'hydrogène. La lithographie atomique par STM a été exploitée, par pointe, sur le LT-UHV-4 STM, en mode manipulation verticale atome-par-atome et mode balayage plus rapide mais rendant l'écriture atomique moins précise. Nous avons construit nos propres fils atomiques puis des plots de contact atomiques, petits carrés de Si(100)H dépassivés de quelques nm de côté. Les courants de fuite à 2 pointes et à l'échelle atomique ont ainsi pu être mesurés sur la surface de Si(100):H entre deux de ces plots. Pour préparer les contacts atomiques à au moins 2 pointes sur un fil atomique ou sur des plots de contact nanométrique, nous avons étudié en détail les différents types de contact pointe STM-liaison pendante unique montrant la difficulté d'atteindre un quantum de conductance au contact, de par un effet de courbure de bandes. Il est donc difficile sans une mesure de force complémentaire de déterminer en partant du contact tunnel les différentes étapes du contact mécanique, électronique au contact chimique. Nos résultats ouvrent la voie à la caractérisation des circuits électroniques construits atome par atome et à l'échelle atomique à la surface d'un semi-conducteur. / The construction of electronic circuits of atomic section is one of the great challenges of the ultimate nanoelectronics. To build an atomic electronic circuit, it is necessary first to develop the dedicated instrument to build up and then to choose the support surface stabilizing this circuit. On the Au(111) surface prepared in ultra-vacuum, we implemented and stabilized the very first LT-UHV-4 STM. This STM 4-probes microscopes scanning at the same time and independently the same surface was built for the CEMES by the ScientaOmicron company. On Au(111), we reproduced all the experimental results obtained on the best LT-UHV-STM with one probe such as the precision in roughness of 2 pm, the IV characteristics recording without any average on a single atom for several tens of minutes and the atomic manipulation following the pulling, sliding and pushing modes of a single gold atom on the surface. Once this optimization was carried out, we applied our LT-UHV-4 STM to the surface of Si(100):H, probable support of the future electronic atomic circuits. The choice of this medium is discussed in detail before recording and analysis of the STM images. The samples used come either from the semi-industrial full-wafer silicon process developed at CEA-LETI or from their in-situ preparation, which takes place directly in the preparation chamber of the LT-UHV-4 STM. We have taken care to interpret the STM images of the surface Si(100):H in order to locate the position of each hydrogen atom. The atomic lithography by STM has been exploited, by using one tip from our LT-UHV-4 STM, by atom-per-atom vertical mode and faster scanning mode. The last makes atomic writing less accurate. We have constructed our own atomic wires and then atomic contact pads, small squares of Si(100)H defeated by a few nm sides. The leakage currents with 2 probes at the atomic scale have thus been able to be measured on the surface of Si(100):H between two of these pads. To prepare the atomic contacts at least 2 probes on an atomic wire or on nanometric contact pads, we studied in detail the different types of contact points STM-single dangling bond showing the difficulty of reaching a quantum of conductance at contact, due to a possible bands bending. It is therefore difficult without a complementary force measurement to determine, starting from the tunnel contact, the different steps of the mechanical, electronic contact at the chemical contact. Our results open the way to the characterization of electronic circuits constructed atom-by-atom and at atomic scale on the surface of a semiconductor.
394

Jonctions tunnel magnétiques à anisotropie perpendiculaire et écriture assistée thermiquement / Magnetic tunnel junctions with out-of-plane anisotropy and thermally assisted writing

Bandiera, Sébastien 21 October 2011 (has links)
Dans le cadre de l'augmentation de la densité de stockage des mémoires magnétorésistives à accès direct (MRAM), les matériaux à anisotropie magnétique perpendiculaire sont particulièrement intéressants car ils possèdent une très forte anisotropie. Cependant, cette augmentation d'anisotropie induit également un accroissement de la consommation d'écriture. Un nouveau concept d'écriture assistée thermiquement a été proposé par le laboratoire SPINTEC. Le principe est de concevoir une structure très stable à température ambiante, mais qui perd son anisotropie lorsqu'elle est chauffée, facilitant ainsi l'écriture. Le but de cette thèse est de valider expérimentalement ce concept. Les premiers chapitres sont consacrés à l'optimisation des matériaux à anisotropie perpendiculaire que sont les multicouches (Co/Pt), (Co/Pd) et (Co/Tb). Leur intégration dans une jonction tunnel magnétique est ensuite présentée. L'évolution de l'anisotropie en température, paramètre crucial au bon fonctionnement de l'assistance thermique, a également été étudiée. Enfin, il est démontré que l'écriture thermiquement assistée est particulièrement efficace : les structures développées présentent une consommation d'écriture réduite par rapport aux structures classiques et une forte stabilité à température ambiante. / In order to increase the storage density of magnetoresistive random access memories (MRAM), magnetic materials with perpendicular anisotropy are very appealing thanks to high anisotropy. However, the enhancement of anisotropy induces an increase of writing consumption as well. A new thermally assisted switching concept has been proposed by SPINTEC laboratory. The principle is to design a highly stable structure at stand-by temperature which loses its anisotropy when heated, making thus the switching easier. The aim of this thesis is to validate experimentally this concept. The first chapters describe the optimisation of out-of-plane magnetic materials such as (Co/Pt), (Co/Pd) and (Co/Tb) multilayers. Their integration in magnetic tunnel junctions is then presented. The evolution of anisotropy with temperature is a critical parameter for thermally assisted writing and has been therefore studied. Finally, the efficiency of this thermally assisted writing is demonstrated: the developed structures present a reduced consumption compared to standard structures and high stability at room temperature.
395

Etude des réponses temporelle et spectrale de l'instrument ECLAIRs pour la mission SVOM / Studies of temporal and spectral responses of the eclairs instrument for the mission svom

Bajat, Armelle 09 October 2018 (has links)
La mission Franco-chinoise SVOM (Space based multi-band Variable astronomical Object Monitor), est dédiée à l'étude des sursauts ƴ, intenses et brèves bouffées de photons en X et ƴ, associées à la formation catastrophique de trous noirs. SVOM embarquera en 2021 quatre instruments observant du visible jusqu'aux rayonnements ƴ. ECLAIRs, télescope principal, est une caméra à masque codé capable de détecter et localiser, environ 200 sursauts pendant les trois années de vie de la mission. Son plan de détection compte 6400 détecteurs CdTe à contact Schottky, qui sont regroupés en matrice de 32 formant un module. Le plan est divisé en huit secteurs électroniquement indépendants, composés chacun de 25 modules. Chaque électronique est dédiée à la lecture et au codage du temps, de la position, de la multiplicité et des énergies des événements détectés sur un secteur. La validation des fonctionnalités de l'électronique de lecture a permis de s'assurer du bon codage des événements, d'estimer les limites de l'électronique et de construire un modèle analytique de correction efficace des événements perdus. Une application à une courbe de lumière d'un sursaut brillant a permis de valider théoriquement ce modèle et des mesures réalisées sur le prototype ont permis de le valider expérimentalement. D'autre part, un modèle complet de la réponse spectrale a été construit afin de caractériser chaque détecteur pavant le secteur du prototype et d'estimer la réponse du plan de détection des photons mono-énergétiques. Les processus physiques des interactions rayonnement-matière ont été simulés ainsi qu'un modèle de perte de charges puis une convolution gaussienne permet de considérer le bruit électronique. Ce modèle, comptant six paramètres libres, est ajusté à des spectres réalisés sur le prototype. L'étude des paramètres extraits caractérise les performances de chaque détecteur dans toutes les configurations de tension et de t peaking et permet d'optimiser les performances de l'instrument. / The french-chinese mission SVOM (Space-based multi-band variable Astronomical Object Monitor), is dedicated to the study of ƴ-rays bursts, brief and intense X and ƴ photons flashes, associated with the catastrophic formation of black holes. SVOM will embark in 2021 four instruments observing from the visible to ƴ rays. ECLAIRs, the main telescope, is a coded mask camera able to detect and locate, about 200 bursts during the three years nominal life time of SVOM. Its detection plan counts 6400 Schottky CdTe detectors, grouped into a matrix of 32 pixels forming a module. The plan is divided into eight electronically independent sectors, each consisting of 25 modules. Each electronic is dedicated to read and encode, the time, the position, the multiplicity and the energies of the detected events on a sector. The validation of each functionality of the readout electronics allows to ensure the correct encoding of the events, to estimate the limits of the electronics and to build an analytical model of lost events efficient correction. An application to a lightcurve of a bright GRB permits to validate theoretically this model and measurements carried out on the prototype validates it experimentally. On the other hand, a complete model of the spectral response has been established to characterize each detector on the sector of the prototype and to estimate the response of the plan of detection of the mono-energetic photons. The physical processes of the radiation-matter interactions are simulated as well as a model of lost charges then a Gaussian convolution takes into account the electronic noise. This model, counting six free parameters, is fitted to spectra measured on the prototype. The study of the extracted parameters characterizes the performance of each detector in every voltage and t peaking configurations optimizing the performance of the instrument.
396

Antennes et dispositifs hyperfréquences millimétriques ultrasouples reconfigurables à base de Microsystèmes Magnéto-Electro-Mécaniques (MMEMS) : conception, réalisation, mesures / Ultrasoft reconfigurable millimeter-wave antennas and devices based on Magneto-Electro-Mechanical Microsystems (MMEMS) : design, fabrication, measurements

Hage-Ali, Sami 30 September 2011 (has links)
Il y a à l'heure actuelle un grand besoin d'antennes reconfigurables dans la bande des 60 GHz pour des applications de télédétection et de télécommunications sans fil très hauts débits. Les solutions traditionnelles de reconfiguration sont basées sur des semiconducteurs ou des composants RF-MEMS, qui connaissent un coût, une complexité et des pertes croissantes en bande millimétrique. Dans cette thèse, une approche originale a été développée : elle est basée sur la reconfiguration mécanique d'antennes et dispositifs millimétriques microrubans sur substrat élastomère ultrasouple PDMS grâce à des actionneurs MEMS grands déplacements. Premièrement, les choix de conception, la technique de simulation éléments finis (HFSS), et surtout la microfabrication d'antennes sur membrane PDMS ainsi que les techniques de mesure en impédance et rayonnement sont abordés.Deux axes ont ensuite été étudiés : les antennes accordables en fréquence, et les antennes et composants pour le balayage angulaire (déphaseurs et antennes à balayage mécanique de type scanner). Des procédés technologiques innovants ont été développés (reports de métallisations épaisses biocompatibles et d'aimants permanents en couches minces sur membrane PDMS) et différentes techniques d'actionnement (pneumatique, magnétique, par électromouillage) ont été mises en œuvre. Les performances en terme d'accord en fréquence (8,2 %) et de balayage angulaire (-90/+100°) dépassent l'état de l'art des antennes du même type en bande millimétrique, et ceci en utilisant une technologie peu complexe, ultra bas-coût et prometteuse pour la montée en fréquence. / There is currently an increasing need for reconfigurable antennas in the 60 GHz band for remote sensing applications and wireless communications. Traditional reconfiguration solutions are based on semiconductors or RF-MEMS but these components face cost, complexity and losses issues at millimeter-waves.In this thesis, an original approach was developed: it is based on the mechanical reconfiguration of millimeter-wave microstrip antennas and devices printed on ultrasoft PDMS substrates, thank to large displacements MEMS actuators. First, the design choices, the finite element simulation technique (HFSS), and the microfabrication of antennas supported by PDMS membranes as well as the impedance and radiation measurements techniques have been discussed. Two axis have then been studied: frequency-tunable antennas, and beam-steering components (phase shifters and "scanner" type antennas). Innovative technological processes were developed (transfer of biocompatible metal patterns and permanent magnet thin films on PDMS membranes) and several actuation techniques (pneumatic, magnetic, electrowetting) were implemented. Performances in terms of frequency tuning (8.2%) and scan angles (-90 / 100 °) are beyond the state of the art for similar antennas in the millimeter-wave band, and are achieved by using a very simple, ultra low-cost technique that is expected to be effective at even higher frequencies.
397

Réalisation de nouvelles structures de cellules solaires photovoltaïques à partir de couches minces de silicium cristallin sur substrat de silicium préparé par frittage de poudres / Realisation of new solar cell structures prepared from crystalline silicon thin films on silicon substrates made by powder sintering

Grau, Maïlys 04 May 2012 (has links)
Les cellules photovoltaïques en couches minces de silicium cristallin sont des candidates prometteuses pour réduire le prix du watt-crête de l'énergie photovoltaïque, grâce à une très faible utilisation de silicium de haute pureté. Dans notre cas, les couches actives de silicium sont supportées par des substrats, de bas coût et compatibles avec les conditions de haute température nécessaires à une croissance cristalline rapide et de bonne qualité des couches. La société S’TILE développe ces substrats, par frittage à partir de poudres de silicium, et en recristallisant les plaquettes ainsi obtenues. Le but de cette thèse est de valoriser ce substrat pour l’industrie photovoltaïque et de démontrer qu’il est adapté à la fabrication de cellules solaires à bas coût et rendement élevé. Ces travaux utilisent le procédé d’épitaxie de silicium, qui est central pour fabriquer des cellules minces. Ils s’articulent autour de deux axes principaux. Le premier est la fabrication de cellules solaires et leur optimisation sur des substrats de référence monocristallins. Dans ce cadre, de nombreuses voies ont été explorées : l’utilisation de réflecteurs de Bragg en silicium poreux, l’optimisation du dopage de l’émetteur, la formation de gradients de dopage dans la base et l’utilisation de structures à émetteur en face arrière. Ces études ont permis d’évaluer le potentiel de ces différentes voies ; des résultats prometteurs pour l’amélioration du rendement de conversion des cellules sur couches minces ont été obtenus. Le second axe de la thèse est la fabrication de cellules sur les substrats frittés préparés par S’TILE et l’application des moyens développés dans le cadre du premier axe pour améliorer ces cellules. Les rendements encoura-geants obtenus ont ainsi démontré la faisabilité de cellules solaires sur les substrats réalisés par le procédé de frittage à bas coût développé par la société S’TILE. / Crystalline silicon thin-film solar cells are promising candidates to reduce the watt-peak prices of photovoltaic energy, thanks to a much smaller use of high purity silicon. In our case, the active layers of silicon are supported by substrates. These substrates have low production costs and are compatible with the high temperature process steps, which are necessary to a rapid and high-quality crystalline growth. The company S’TILE develops these substrates, by sintering silicon powders and recrystallizing the obtained wafers. The objective of this PhD thesis is to pinpoint the relevance of this substrate for the photovoltaics industry and demonstrate that it is adapted to the fabrication of solar cells with low cost and high efficiency. This work uses the epitaxy process, which is central to fabricate these thin-film cells. It is organized in two main axes. The first one is the fabrication of solar cells and their optimization on monocrystalline reference substrates. Several optimization pathways have been tested: the use of porous silicon Bragg reflectors, the optimization of emitter doping, the base variable doping and the use of rear emitter structures. The studies permitted to unveil the potential of each pathway; promising results were obtained for the improvement of thin-film solar cell conversion efficiency. The second axis of the thesis is the cell fabrication on the substrates prepared by S’TILE and the application of the means developed in the first axis to improve these cells. Encouraging efficiencies have demonstrated the feasibility of solar cells on the substrates made by the low-cost process developed by S’TILE.
398

Implantable microelectrode biosensors for neurochemical monitoring of brain functioning / Microcapteurs implantables pour le suivi neurochimique de fonctionnement du cerveau

Vasylieva, Natalia 11 September 2012 (has links)
Les microcapteurs implantables sont des outils de choix pour l’étude du système nerveux central. Ils permettent d’analyser en temps réel la composition du milieu interstitiel du cerveau et les variations de concentration de neurotransmetteurs et de substrats métaboliques dans l’espace extracellulaire. La procédure d’immobilisation de l’enzyme sur l’électrode est une étape cruciale déterminant les performances du biocapteur. Nous avons développé une méthode d’immobilisation simple, non-toxique et peu chère en utilisant une molécule de poly(ethyleneglycol) diglycidyl éther (PEGDE) qui répond bien aux critères des applications cliniques. La méthode a été étudiée et optimisée sur trois enzyme: la Glucose oxydase, la D-amino acide oxydase et la Glutamate oxydase. Les capteurs développés se caractérisent par une forte sensibilité et un temps de réponse suffisamment court pour la détection des événements biologiques en temps réel. Les capteurs à base de PEGDE ont démontrés une bonne stabilité dans le temps et leur capacité de suivre en temps réel la variation de concentration de glucose dans le SNC du rat suite à l’injection d’insuline ou de glucose. Nous avons également adapté les méthodes d’immobilisation d’enzyme les plus utilisées dans le domaine des neurosciences: immobilisation par réticulation dans des vapeurs de Glutaraldéhyde ou par PEGDE, piégeage dans une matrice de sol-gel ou de polypyrrole dérivé, ou immobilisation dans une matrice d’hydrogel. Nous avons comparé les biocapteurs ainsi obtenus en termes de sensibilité, de stabilité in vivo, de temps de réponse et aussi de toxicité. Cette étude comparative nous a permis de conclure que le PEGDE représente un procédé d’immobilisation optimal car il ne demande pas de synthèse organique, contrairement à l’hydrogel, il n’est pas toxique contrairement au glutaraldehyde et il assure une immobilisation covalente plus stable que le piégeage dans des sol-gel ou polypyrrole. Cette étude comparative a mis également en évidence l’effet de la procédure de fixation de l’enzyme sur la spécificité du biocapteur. Nous avons montré que l’immobilisation par glutaraldehyde provoque une importante perte de sélectivité de l’enzyme. Quant au PEGDE, son immobilisation est assez douce pour préserver la spécificité naturelle de l’enzyme. Nous avons montré que la procédure d’immobilisation a un impact important sur la quantification des molécules dans les échantillons biologiques et in vivo. La validité des mesures sur nos capteurs a été contrôlée par HPLC ou électrophorèse capillaire. Nous avons également développé des sondes multisensibles en utilisant les techniques de microfabrication sur silicium. Le dispositif comporte une aiguille de 6mm en longueur, 100µm en largeur et 50 µm en épaisseur. Elle porte trois électrodes de taille 40x200µm. Ces dispositifs, optimisés pour réduire les effets d’interférence entre les électrodes, ont été pour le suivi simultané de glucose et lactate dans le SNC de rats anesthésiés. / Identification, monitoring and quantification of biomolecules in the CNS is a field of growing interest for identifying biomarkers of neurological diseases. In this thesis, silicon needle-shaped multi-molecules sensing microprobes were developed. Our microelectrode array design comprises a needle length of 6mm with 100x50 µm2 cross-section bearing three platinum electrodes with a size of 40x200 µm and 200µm spacing between them. We have used these microprobes for simultaneous glucose and lactate monitoring, using the third electrode for control of non-specific current variations. Local microdroplet protein deposition on the electrode surface was achieved using a pneumatic picopump injection system. Enzyme immobilization on the electrode surface is a key step in microelectrode biosensor fabrication. We have developed a simple, low cost, non-toxic enzyme immobilization method employing poly(ethyleneglycol) diglycidyl ether (PEGDE). Successful biosensor fabrication was demonstrated with glucose oxidase, D-amino acid oxidase, and glutamate oxidase. We found that these biosensors exhibited high sensitivity and short response time sufficient for observing biological events in vivo on a second-by-second timescale. PEGDE-based biosensors demonstrated an excellent long-term stability and reliably monitored changes in brain glucose levels induced by sequential administration of insulin and glucose solution. We then carried out a comparative study of five enzyme immobilization procedures commonly used in Neuroscience: covalent immobilization by cross-linking using glutaraldehyde, PEGDE, or a hydrogel matrix and enzyme entrapment in a sol-gel or polypyrrole-derived matrices. Enzymatic microelectrodes prepared using these different procedures were compared in terms of sensitivity, response time, linear range, apparent Michaelis-Menten constant, stability and selectivity. We conclude that PEGDE and sol-gel techniques are potentially promising procedures for in vivo laboratory studies. The comparative study also revealed that glutaraldehyde significantly decreased enzyme selectivity while PEGDE preserved it. The effects that immobilization can have on enzyme substrate specificity, produce dramatic consequences on glutamate detection in complex biological samples and in the CNS. Our biosensor’s results were systematically controlled by HPLC or capillary electrophoresis. The highly selective PEGDE-based biosensors allowed accurate measurements glutamate concentrations in the anesthetized and awaked rats at physiological conditions and under pharmacological and electrical stimulations. The microfabricated multielectrodes based on silicon needles coupled to the simple, non-toxic and mild immobilization method based on PEGDE, open new possibilities for specific neurotransmitter detection in the central nervous system and the study of cell-cell communication in vivo.
399

Procédés laser pour la réalisation de cellules photovoltaïques en silicium à haut rendement / Laser processing for high efficiency silicon solar cells

Poulain, Gilles 25 October 2012 (has links)
L'énergie photovoltaïque est promise à une forte croissance dans les prochaines années. Propre et renouvelable, elle possède en effet de sérieux atouts pour répondre aux grands enjeux posés par le réchauffement climatique et l'appauvrissement des ressources en énergie fossile. Elle reste néanmoins une énergie chère en comparaison des autres formes de production électrique. D'importants efforts de R&D doivent être mis en œuvre pour abaisser son coût et la rendre plus compétitive. Il existe d'ores et déjà dans les laboratoires des technologies permettant d'augmenter significativement le rendement des cellules solaires en silicium (qui représentent aujourd’hui l'essentiel du marché). Mais elles font appel le plus souvent à des procédés, comme la photolithographie, qui restent chères pour l'industrie photovoltaïque. Les technologies laser sont une voie envisagée pour répondre à ce problème. Sélectifs, sans contact et autorisant de hautes cadences, les procédés laser permettent de réaliser des structures avancées de cellules à moindre coût. Il existe ainsi une forte dynamique de recherche autour de ces procédés. Les traitements laser permettent d’usiner ou de modifier la matière, de façon rapide et fiable. Il est ainsi possible d’ablater sélectivement certains matériaux, de réaliser des tranchées ou des trous, ou encore de modifier des profils de dopage. Des architectures complexes deviennent ainsi accessibles sans recourir aux couteuses technologies de la microélectronique. C'est dans ce contexte que se déroule ce travail de thèse, financé par l'ADEME et la société SEMCO Eng., et s'inscrivant également dans le projet de l'Agence National pour la Recherche PROTERRA. Deux objectifs principaux ont motivé sa mise en place : développer un savoir-faire au laboratoire INL sur les technologies laser avec l'ambition de rejoindre les instituts leaders sur ces thématiques et transférer les procédés développés à l'équipementier SEMCO Eng. pour lui donner accès à une technologie aujourd'hui inédite dans l'industrie photovoltaïque française. Ces recherches ont porté sur les cellules photovoltaïques en silicium, dites de première génération, et se sont articulées autour de trois axes principaux : la modélisation de l'interaction laser matière, l'ablation sélective de diélectriques (notamment de la couche antireflet afin de permettre de nouvelles techniques de métallisation) et la réalisation de dopages localisés. Des cellules de grandes dimensions fabriquées en collaboration avec SEMCO Eng. et tirant parti de ces procédés ont permis d’obtenir des rendements en accord avec l’état de l’art (proche de 18 %). / Silicon solar cells still require cost reduction and improved efficiency to become more competitive. New architectures can provide a significant increase in efficiency, but today most of the approaches need additional fabrication steps. In this context, laser processing offers a unique way to replace technological steps like photolithography that is not compatible with the requirements of the photovoltaic industry. This PhD thesis will present two promising laser processes for silicon solar cells: selective laser doping and selective laser ablation. Laser-assisted diffusion of dopants is a promising way to produce at low cost advanced silicon solar cells with high efficiency. Indeed, selective emitters, which rely on high dopant concentration localized under the front electrical contacts are an effective way to reduce power losses at the front surface of silicon solar cells. Several laser-based techniques are competing to optimise the emitter geometry. One of the main approaches is to take advantage of the doping glass (usually P2O5 for p-type silicon solar cells) that is formed during the standard diffusion process. Selective laser ablation is an effective way to open the antireflection layer (SiNx) in order to perform alternative front side metallization. Indeed, in the industrial production of standard silicon solar cells, the front side metallization is made by screen printing of metal paste. This process scheme is very cost efficient but it leads to serious limitations of the solar cell efficiency. Electrochemical metallization avoids these issues but requires a selective opening of SiNx, which is usually done by photolithography. Direct laser ablation allows to consider this approach at an industrial level. These processes are presented illustrated by research conducted during this PhD at INL in laser technologies for photovoltaics. An innovative and potentially self-aligned process is also discussed, where the laser is used to open locally the antireflection and passivation coating, and at the same time, achieve local phosphorus diffusion. Moreover solar cells results above 18% have been obtained thanks to a selective emitter structure achieved with selective laser doping.
400

Intégration sur silicium et caractérisation de films minces de polyuréthane nanocomposite pour le développement de micro-actionneurs MEMS électrostrictifs / Silicon integration and characterization of polyurethane nanocomposite thin films to the development of electrostrictive micro-actuators MEMS

Roussel, Michael 17 December 2012 (has links)
Ce travail de thèse s'inscrit dans le cadre général du développement de micro-actionneurs MEMS, à bas coût et de technologie simple, pour de futures applications dans le domaine de la microfluidique, notamment. La motivation de ce travail est d'évaluer la faisabilité d'un micro-actionneur électrostricitf à base de film mince polymère électroactif nanocomposite. Le polyuréthane, chargé en nanoparticules de carbone ou carbure de fer, encore peu étudié mais aux propriétés électrostrictives prometteuses, est choisi comme matériau à intégrer dans une filière MEMS silicium classique. Le premier chapitre dresse un état de l'art sur les actionneurs MEMS, présente les différentes familles de polymères électroactifs et définit ce qu'est l'électrostriction. Le second chapitre est consacré à l'intégration sur silicium de films minces de polyuréthane et au développement de différentes structures de tests. L'accent est mis sur la levée de plusieurs verrous technologiques. Le chapitre trois présente les méthodes de caractérisations mécaniques et électriques et les résultats obtenus sur films purs et nanocomposites. Le quatrième et dernier chapitre concerne la réalisation et la caractérisation de premiers démonstrateurs MEMS. Ces micro-actionneurs sont caractérisés de manière statique et dynamique. / This thesis is part of the general development of MEMS microactuators, low cost and simple technology for future applications in the domain of microfluidics. The motivation of this work is to evaluate the feasibility of an electrostrictive microactuator based on electroactive nanocomposite polymer thin films. Polyurethane, loaded with carbon or iron carbide nanoparticles is chosen to be integrated in a conventional silicon MEMS process. The first chapter provides a state of the art of MEMS actuators, presents the different families of electroactive polymers and defines what is electrostriction. The second chapter is devoted to the integration of polyurethane thin films on silicon and to the development of different mechanical and electrical test structures. The emphasis is on identifying and overcoming technological barriers. Chapter three presents the mechanical and electrical characterization methods and the obtained results for pure and nanocomposites films. The fourth and final chapter concerns the realization and the static and dynamic characterizations of first MEMS demonstrators.

Page generated in 0.0685 seconds