71

Estudo experimental de enlace analógico a fibra óptica empregando WDM e sinais de RF multi-espectral

André Paim Gonçalves 28 March 2014 (has links)
Este trabalho está organizado com o objetivo de apresentar um estudo teórico e experimental do enlace de sinais analógicos de RF por fibra óptica empregando técnica de multiplexagem por divisão de comprimento de onda (WDM) sem amplificação. Este enlace apresenta uma arquitetura utilizando moduladores eletro-ópticos do tipo Mach-Zehnder e multiplexadores/demultiplexadores do tipo Arrayed Waveguide Grating (AWG). O emprego deste enlace a fibra óptica visa à transmissão de sinais de RF às antenas remotamente localizadas em relação à estação geradora do sinal, distribuição de sinais de RF e recepção de sinais de RF de um parque de antenas distribuídas remotamente da estação de análise de sinais. Realizou-se uma análise de alguns dos parâmetros de desempenho do enlace, bem como de alguns efeitos que o afetam. Esta análise se pautou em cálculos referentes às características individuais dos diversos componentes que integram o sistema. Posteriormente, foi implementada a verificação e validação dos cálculos com base em medições feitas no Laboratório de Guerra Eletrônica do ITA. Estes cálculos se basearam em fundamentos teóricos sobre alguns fenômenos físicos presentes nos dispositivos empregados neste tipo de enlace WDM passivo. Estes fenômenos são a propagação da onda eletromagnética em meios anisotrópicos e não lineares, efeito eletro-óptico, linearidade de moduladores, multiplexagem óptica no AWG, perdas por inserção e diafonia. Foram propostas arquiteturas de enlaces passivos do tipo WDM NxN (com o demutiplexador) e do tipo WDM Nx1 (sem o demutiplexador). Respeitaram-se as características individuais dos componentes constituintes do enlace e as condições de operação do sistema, tais como a tensão de polarização, a influência da intensidade do sinal óptico na fibra óptica e a influência do meio óptico no sinal de RF modulado acoplado a fibra óptica e convertido no fotodetector. Empregaram-se os parâmetros S para análise do sistema. As formulações matemáticas para o cálculo do ganho de potência do sinal de RF no enlace foram discutidas e inter-relacionadas. Estas formulações matemáticas dão origem ao método com reduzidas quantidades de simplificações aplicando o teorema de Graf e ao método para pequenos sinais. Foram também abordados os efeitos de distorção harmônica inerentes ao processo de modulação do sinal óptico e os efeitos que a dispersão no meio de propagação óptica produzem no sinal de RF de saída do enlace, bem como os limites de potência para evitar os efeitos não lineares na fibra óptica. Verificou-se em laboratório a consistência do método de cálculo do ganho de potência de RF que emprega o teorema de Graf. Foram apresentas algumas aplicações do enlace de sinais analógico de RF a fibra óptica com o emprego de WDM, sem amplificação óptica, em geração de sinais em raias de cenários de GE simulados, em recepção remota de sinais (tanto para fins militares como civis) e em distribuição de sinais a bordo de navios.
72

A contribution to aeroelasticity using lyapunov's theory

Douglas Domingues Bueno 18 June 2014 (has links)
The main idea of this work is to apply the general theory of stability introduced by Lyapunov and to use linear matrix inequalities (LMIs) to study different issues in aeroservoelasticity. Many approaches have been developed on the control theory field involving LMIs, however, there is a limited number of works in the literature focused on aeroelasticity. That preliminary motivation allowed the development of different approaches on this topic. Three benchmark systems were used to evaluate and demonstrate these approaches. The first one is the three degree of freedom airfoil section and the second one is the AGARD 445.6 wing. The third benchmark system is the two degree of freedom pitch and plunge apparatus. The aerodynamic forces were computed using the Theodorsen';s theory and the Doublet Lattice method. Four different issues involving stability and control are discussed. The first one is the inclusion of structural uncertainties on the stability analysis. The second topic introduces the concept of continuous analysis and allows the study of stability of time-variant aeroelastic systems. The third issue comprises the design of controllers to suppress limit cycle oscillations in aeroelastic systems including discrete nonlinearities based on the Fuzzy Takagi-Sugeno modeling and, finally, the last topic proposes the use of Grammian matrices to determine the linear stability specially when a large number of cases of analysis are considered in the flight envelope. The introduced ideas are very promising for aeroservoelastic analysis using LMIs.
73

Calibração de arranjo para ensaios de detecção de fumaça em compartimentos de carga de aeronaves

Carolina Rodrigues Ramos Pinto 07 February 2013 (has links)
Na aviação existem requisitos que devem ser cumpridos para que uma aeronave esteja aeronavegável. Estes requisitos são aprimorados em função da evolução tecnológica e com a investigação de acidentes que resultam em lições aprendidas. O enfoque desta pesquisa é no requisito de segurança de cabine que aborda a detecção de fogo e fumaça dentro dos compartimentos de carga nas aeronaves. Trata-se do requisito FAR part 25, 25.858, para cujo cumprimento é necessária a instalação de detectores de fumaça nos compartimentos. Pela análise da literatura, verificou-se que existe uma grande subjetividade para a definição da fumaça ideal na realização dos ensaios de certificação das instalações do sistema de detecção de fumaça, uma vez que o critério utilizado é um vídeo disponibilizado pelo FAA (Federal Aviation Administration), porém vários fatores influenciam na escolha da fumaça ideal, como a iluminação do ambiente, ventilação, cor de fundo apresentados no vídeo. Dentro desse contexto essa pesquisa tem como objetivo principal determinar uma recomendação de calibração dos equipamentos utilizados para os ensaios de detecção de fumaça. Para atingir o objetivo principal, foram definidos objetivos específicos que incluem Definir a fumaça padrão através do Engineering judment de especialistas do ramo, propor uma instrumentação para a calibração da fumaça, caracterizar a fumaça através da instrumentação proposta. Diante desse cenário foi elaborado um procedimento experimental para avaliar diferentes fumaças, medi-las para identificar a resposta da instrumentação proposta por essa pesquisa, e conforme protocolo do procedimento, caracterizar a fumaça ideal através de dados mensuráveis de transmissibilidade. Os dados dos ensaios foram analisados com auxílio de ferramentas estatísticas. Os resultados mostraram que a instrumentação proposta é efetiva e foi determinada uma recomendação para a calibração dos equipamentos.
74

Avaliação de dispositivos médicos na percepção do usuário : um estudo de caso com pacientes de hemodiálise

Grebin, Sabrina Zanatta January 2016 (has links)
Os dispositivos médicos desempenham um papel crucial na gestão de doenças crônicas, e são utilizados por diferentes usuários, em configurações variadas de ambientes, para o tratamento de diferentes doenças com diferentes níveis de gravidade. Esta dissertação tem por objetivo contribuir na captação, mensuração e análise da percepção do usuário em relação ao uso do dispositivo médico. Como objetivos secundários, tem-se: (i) analisar na literatura abordagens e técnicas de avaliação da usabilidade de dispositivos médicos sob a perspectiva do usuário; (ii) desenvolver e ilustrar, através de um estudo de caso com pacientes de hemodiálise, uma metodologia para avaliação da usabilidade de dispositivos médicos; e (iii) apresentar um procedimento de análise para avaliar a usabilidade de dispositivos médicos na perspectiva do paciente de hemodiálise, identificando quais características do contexto de uso podem afetar esta avaliação. Para atingir os objetivos de pesquisa, a dissertação é composta por três artigos que contemplam cada um dos objetivos mencionados anteriormente. No primeiro artigo foram avaliados 42 estudos, na qual cinco abordagens foram mais comumente utilizadas: entrevista, testes de usabilidade, percurso cognitivo, observação e questionário. Para o segundo e terceiro artigos, um estudo de caso com pacientes de hemodiálise foi conduzido. Questionários estruturados foram aplicados para pacientes em ambientes reais de uso, contendo questões a cerca da percepção de uso (máquina, procedimento e ambiente). No segundo artigo uma metodologia para avaliação centrada no usuário de dispositivos médicos foi proposta. Um fluxo detalhado foi gerado, composto por três etapas: planejamento, estudo de campo e análise dos dados, desdobrados em nove subetapas. No terceiro artigo, duas técnicas estatísticas, a Análise de Variância Multivariada (MANOVA) e Análise Fatorial Exploratória (AFE), foram empregadas para investigar a existência de diferenças nos níveis de satisfação do usuário com os aspectos de uso, além da extração de um menor número de fatores para explicar a satisfação geral do usuário. / Medical devices play a crucial role in chronic disease management, and are used by different users in different environments settings for the treatment of different diseases with different levels of severity. This dissertation aims at contributing to the capture, user perception of measurement and analysis regarding the use of the medical device. As secondary objectives, we have: (i) review the literature approaches and techniques for assessing the usability of medical devices in the user's perspective; (Ii) develop and illustrate through a case study of hemodialysis patients, a methodology for evaluating the usability of medical devices; and (iii) present an analysis procedure to evaluate the usability of medical devices in the hemodialysis patient's perspective, identifying context of use characteristics may affect this assessment. To achieve the research objectives, the dissertation consists of three articles that address each of the objectives mentioned above. In the first article were evaluated 42 studies in which five approaches have been most commonly used: interview, usability testing, cognitive route, observation and questionnaire. For the second and third articles, a case study of hemodialysis patients was conducted. Structured questionnaires were administered to patients in actual use environments, with questions about the perception of use (machine, process and environment). In the second article a methodology to assess user-centric medical device has been proposed. A detailed flow was generated, consisting of three stages: planning, field of study and analysis of the data, broken down into nine sub-steps. In the third article, two technical statistics, Multivariate Analysis of Variance (MANOVA) and exploratory factor analysis (EFA) were employed to investigate the existence of differences in user satisfaction levels with aspects of use, and the extraction of a minor number of factors to explain the overall user satisfaction.
75

A tecnologia na saúde: uma análise crítica

Yomali Ospina López, Diana January 2007 (has links)
Made available in DSpace on 2014-06-12T17:41:12Z (GMT). No. of bitstreams: 2 arquivo7294_1.pdf: 1448407 bytes, checksum: b5b8fdc4efa0dee041c2ec98d640de07 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2007 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / O trabalho tem como objetivo analisar a dinâmica das implicações recíprocas entre tecnologia e saúde com ênfases no Brasil. Para tanto, procurou-se abordar a saúde no Brasil conhecendo um pouco da história do sistema de saúde do país e dos principais agentes desse sistema: os médicos, a indústria farmacêutica, a indústria de equipamentos médico-hospitalares, as empresas de seguro de saúde, o governo, os hospitais e os usuários. Posteriormente, tratou-se o tema do avanço da tecnologia, pois se observa que à medida que a tecnologia na saúde avança seus preços aumentam contrariamente ao que ocorre em outras áreas. Neste contexto é descrito, no decorrer desta dissertação, o sistema de saúde dentro das características do sistema de produção, sendo inserido dentro da programação linear e apresentando um modelo de alocação no sistema de saúde para descrever o comportamento na escolha de uma tecnologia. Neste trabalho também foi feita à montagem de uma base de dados com informações extraídas do Departamento de Informática do Sistema Único de Saúde (DATASUS) do Sistema de Cadastro Nacional de Estabelecimentos de Saúde (SCNES) dos estabelecimentos cadastrados nos estados do Ceará, Goiás, Pará, Pernambuco, Rio Grande do Sul e São Paulo, correspondentes aos meses de agosto a dezembro de 2005, e de janeiro a junho de 2006, e foram feitas algumas análises dos dados coletados
76

Gestão do risco de falha do preventor anular de BOP multiplexado submarino. / Risk management for annular preventer of multiplexed submarine bop.

Nikolas Lukin 19 May 2016 (has links)
Após o acidente de Macondo (EUA, 2010), cujo prejuízo estimado é da ordem de US$ 42 bilhões, a análise de risco do BOP (Preventor de BlowOut) ganhou grande importância nos projetos de exploração e desenvolvimento de petróleo. O presente trabalho se aprofundou na análise de risco de falha no acionamento do preventor anular de BOP (uma das funções do BOP), mapeando a sensibilidade da manutenção, redundâncias do projeto e da vida útil dos componentes no risco de falha inerente ao seu funcionamento. Este estudo seguiu os fundamentos da inspeção baseada no risco e da manutenção centrada na confiabilidade, a partir das diretrizes das normas ISO 31.000 (gestão do risco) e API 581 (inspeção baseada no risco). Um modelo de confiabilidade foi construído com base na árvore de falhas do equipamento, a qual, por sua vez, foi construída com base no diagrama hidráulico do sistema e do respectivo FMEA (Failure Mode and Effect Analysis). Neste modelo, pressupõe-se uma taxa de falhas constante dos componentes ao longo do tempo para calcular o tempo médio entre falhas do sistema. O trabalho atendeu seus objetivos ao comprovar que o modelo numérico de confiabilidade é aderente às falhas de campo e da literatura. A análise de sensibilidade do modelo por meio da simulação numérica, mostrou que o aumento da qualidade das manutenções preventiva é a melhor estratégia para reduzir o risco de falha do BOP anular. Verificou-se ainda que o aumento da vida útil de alguns componentes é tão relevante quanto o incremento de redundâncias para a confiabilidade do BOP anular. / After Macondo accident (USA, April 2010), with an estimated loss of US $ 42 billion, the failure risk analysis of the BOP (BlowOut Preventor) gained great importance in oil exploration and development projects. This work has deepened in BOP annular preventer (one of BOP functions) failure risk analysis, mapping sensitivity of maintenance of its components in the probability of equipment failure, according to the guidelines of RBI techniques (Risk Based Inspection) and RCM (Reliability Centered Maintenance). Therefore, the methodology used is proposed by API 580 (2009) and API 581 (2008) standards of risk based inspection applied on a reliability model of annular BOP. This reliability model, in turn, was based on fault tree analysis (FTA) and FMEA (Failure Mode and Effect Analysis) over the equipment hydraulic diagram. As hypothesis, it is assumed a constant failure rate of components over time, in order to calculate the mean time between failures. It was proved that reliability calculated by numerical model is coherent to field failures observations and literature data. The sensitivity analysis by numerical simulation shows that improving inspections and preventive maintenance quality in some of BOP components can markedly reduce the risk of failure of annular BOP.
77

PREVALÊNCIA E FATORES ASSOCIADOS À UTILIZAÇÃO DE EQUIPAMENTOS DE PROTEÇÃO INDIVIDUAL (EPI) ENTRE OS PROFISSIONAIS DE SAÚDE ACIDENTADOS COM MATERIAL BIOLÓGICO NO ESTADO DO MARANHÃO / PREVALENCE AND FACTORS ASSOCIATED WITH THE USE OF INDIVIDUAL PROTECTION EQUIPMENT (IPE) AMONG HEALTH PROFESSIONALS INCIDENTED WITH BIOLOGICAL MATERIAL IN THE STATE OF MARANHÃO

CORRÊA, Luciana Barroso Dias 24 January 2017 (has links)
Submitted by Daniella Santos (daniella.santos@ufma.br) on 2017-06-23T12:21:34Z No. of bitstreams: 1 Luciana Barroso.pdf: 1746841 bytes, checksum: 6cee0678ba4430d113560cba6632a608 (MD5) / Made available in DSpace on 2017-06-23T12:21:34Z (GMT). No. of bitstreams: 1 Luciana Barroso.pdf: 1746841 bytes, checksum: 6cee0678ba4430d113560cba6632a608 (MD5) Previous issue date: 2017-01-24 / Health professionals are exposed to the risk of occupational accidents due to the direct and constant manipulation of blood and body fluids of patients, sources of pathogen transmission. Personal protective equipment (PPE) acts as a barrier and promotes protection whenever there is a possibility of exposure to biological material. The objective of this study is to investigate the use of PPE among health professionals injured with biological material in the state of Maranhão. Therefore, a cross-sectional epidemiological study was carried out with all health professionals injured with biological material in the period from 2010 to 2015, based on the SINAN database, which was made available By the State Department of Health of Maranhão. The variables of the study were: age, sex, schooling, occupation, work situation, length of service, accident location, accident circumstance, accident type, organic material involved, causative agent. These variables were organized in blocks, arranged in a hierarchical structure (distal level, intermediate level and proximal level) and analyzed in the program STATA version 12.0, with the response variable being the use of individual protection equipment. They were considered to be associated with the variable response to those with p-value <0.05. At the end of the hierarchical analysis, they were associated with non-use of PPE: age from 18 to 30 years (RP = 0.96, p = 0.040), having ≤12 years of study (RP = 1.04, p = 0.043 (RP = 1.04, p = 0.011), percutaneous exposure (PR = 1.02, p = 0.010), per blood (RP = 1.01, p = 0.003) and by inappropriate discharge of sharps (RP = 1.05, p = 0.004). The proper use of personal protective equipment is still largely neglected by health professionals, requiring training and specific training on biosafety standards. / Os profissionais de saúde estão expostos ao risco de acidentes ocupacionais devido à manipulação direta e constante de sangue e fluidos corpóreos de pacientes, fontes de transmissão de patógenos. Os equipamentos de proteção individual (EPI) funcionam como barreira e promovem proteção sempre que houver possibilidade de exposição a material biológico. Tem-se, neste trabalho, como objetivo investigar a utilização de EPIs entre os profissionais de saúde acidentados com material biológico no estado do Maranhão. Para tanto, realizou-se um estudo epidemiológico, transversal, tipo analítico com todos os profissionais de saúde acidentados com material biológico no período de 2010 a 2015, a partir do banco de dados do Sistema de Informação de Agravos de Notificação (SINAN), disponibilizado pela Secretaria de Estado da Saúde do Maranhão. As variáveis do estudo foram: faixa etária, sexo, escolaridade, ocupação, situação de trabalho, tempo de serviço, localidade do acidente, circunstância do acidente, tipo de acidente, material orgânico envolvido, agente causador. Estas variáveis foram organizadas em blocos, dispostas em uma estrutura hierarquizada (nível distal, nível intermediário e nível proximal) e analisadas no programa STATA versão 12.0, tendo como variável resposta a utilização de equipamentos de proteção individual. Foram consideradas associadas à variável resposta àquelas que apresentaram p-valor <0,05. Ao final da análise hierarquizada, mantiveram-se associados a não utilização de EPI: idade de 18 a 30 anos (RP=0,96; p=0,040), ter ≤12 anos de estudo (RP=1,04; p=0,043), trabalhar na capital/região metropolitana (RP=1,04; p=0,011), exposição percutânea (RP= 1,02; p=0,010), por sangue (RP=1,01; p=0,016), por agulha (RP=1,01; p=0,003) e por descarte inadequado de perfurocortantes (RP=1,05; p=0,004). O uso adequado de equipamentos de proteção individual ainda é bastante negligenciado pelos profissionais de saúde, sendo necessários treinamentos e capacitação específica sobre normas de biossegurança.
78

Comportamento de três protetores auriculares tipo concha, em ambientes com ruídos em baixa freqüência

Nielsen, Rudolf Moth January 2001 (has links)
Esta dissertação consiste no estudo comparativo entre três tipos básicos de protetores auriculares do tipo concha (modelo simples de baixo preço e baixo NRR, modelo sofisticado, de maior custo e com NRR elevado, e modelo ativo com circuito eletrônico de cancelamento de ruído), tanto quanto ao conforto quanto às reais atenuações oferecidas pelos mesmos, num ambiente industrial com elevados níveis de ruído e de baixa freqüência (com predominância na faixa de 500 Hz). Para a análise dos protetores foram utilizadas a técnica MIRE (Miniature Microphone in Real-Ear, ou Microfone Miniatura no Ouvido Real) de avaliação do nível de atenuação, o uso de questionários de conforto, e medições de cortisol urinário, para a avaliação do estresse no trabalho. Os resultados indicaram que o protetor ativo não apresentou os resultados esperados em termos de atenuação, o que não justifica o seu elevado custo, e apresentou a pior condição de conforto entre os três tipos estudados. As medições do cortisol urinário, por sua vez, não apresentaram resultados que pudessem ser úteis na escolha do melhor modelo de protetor tipo concha.
79

Desempenho de equipamentos de drenagem urbana da cidade de Franca / Performance of urban drainage equipments the city of Franca

Alexandre Artioli de Camargo Godoi 22 June 2006 (has links)
A análise sobre o comportamento e o desempenho de elementos para drenar que compõem galerias pluviais pode contribuir para identificar informação, métodos e técnicas que orientem decisões sobre ações preventivas e corretivas para controle de processos de erosão e inundações, uma contribuição à orientação sobre diretrizes para melhoria da qualidade de vida. Esta dissertação de mestrado relata e discute resultados obtidos ao mostrar que a simulação de movimento de água em sarjetas, bocas de lobo e galerias pluviais pode contribuir para comparar as conseqüências de alteração de especificações e processos de projeto, escolha de equipamentos e controle de obras de drenagem. O conhecimento de índices de comportamento de características de fluxo de água pode contribuir para identificar conseqüências do funcionamento de equipamentos para drenar vias urbanas. O método adotado foi um processo de simulação decorrente de uma escolha de variáveis e índices de desempenho de equipamentos de drenagem, hipóteses e critérios para estimar características de movimento de água. Para estudo de caso foram usados dados obtidos na cidade de Franca, estado de São Paulo. O principal processo adotado foi o manuseio de resultados de estimativas sobre características de fluxo e vazões em obras existentes, produtos de observação sobre dados obtidos ao refazer projetos de redes de galerias pluviais em operação / The analysis on the behavior and the acting of elements to drain that composes pluvial galleries can contribute to identify information, methods and techniques that guide decisions about preventive and corrective actions for control of erosion processes and floods, a contribution to the orientation on guidelines for improvement of the life quality. This work tells and it discusses results obtained when showing that the simulation of movement of water in gutters and pluvial galleries can contribute to compare the consequences of alteration of specifications and project processes, choice of equipments and control of drainage works. The knowledge of indexes of behavior of characteristics of flow of water can contribute to identify consequences of the operation of equipments to drain urban roads. The adopted method was a simulation process due to a choice of variables and indexes of acting of drainage equipments, hypotheses and criteria to esteem characteristics of movement of water. For case study were used data obtained in the city of Franca, state of São Paulo, Brazil. The main work process was the handling of results of estimates on flow characteristics and flows of existent works, observed from new data obtained when redoing the projects of pluvial galleries in operation
80

Análise das inconformidades do Centro de Material e Esterilização com base na RDC ANVISA nº15/2012 para julgamento da gravidade validada por especialistas / Analysis of nonconformities of the Material and Sterilization Center based on DRC ANVISA nº15 / 2012 for severity-validated judgment by specialists [thesis]. São Paulo: Escola de Enfermagem, Universidade de São Paulo; 2016.

Lisbeth Lima Hansen 24 February 2017 (has links)
Introdução: A existência de uma relação importante entre o uso de produtos para a assistência à saúde e a ocorrência de infecções, torna prioritário estabelecer medidas eficazes de processamento daqueles passíveis de reuso.O Centro de Material e Esterilização (CME) tem como missão fornecer produtos para saúde (PPS) seguramente processados, ou seja, limpos, desinfetados ou esterilizados, livres de biofilmes, de endotoxinas, de proteínas priônicas e de substâncias tóxicas, e ainda funcionalmente efetivos.No Brasil, o CME tem as suas Boas Práticas regulamentadas por legislação federal da Agência Nacional de Vigilância Sanitária desde 15/03/2012 por meio da Resolução da Diretoria Colegiada (RDC) nº 15. Expirado o prazo de 24 (vinte e quatro) meses contados a partir da data de sua publicação para que os CME fizessem as adequações necessárias, pode-se inferir que muitos dos serviços de saúde e das empresas processadoras abrangidos por esta Resolução não conseguiram atender integralmente as exigências legais. Analisando a RDC ANVISA nº 15, nem todos os itens se encaixam no mesmo nível desegurança para os PPS processados,ou seja, numa situação de inspeção sanitária as inconformidades não devem ser consideradas com a mesma gravidade. Apresente análise das inconformidades do Centro de Material e Esterilização com base na RDC ANVISA nº15/2012 para julgamento da gravidade validada por especialistaspoderá subsidiaro gestor do CME na priorização de planos de ação junto à administração do Estabelecimento de Saúde para tornar o serviço conforme com a legislação vigente. Objetivo: Analisar asinconformidades apresentadas pelo CME, com base na RDC ANVISA nº15/2012 para julgamento da gravidade esubmeter a validação por especialistas. Materiais e métodos: Tratou-se deuma pesquisa metodológica, que consistiu na atribuiçãode gravidade para 132 inconformidades em relação ao não cumprimento de 89 itens da RDC ANVISA nº 15/2012. Atribuiu-se gravidadealtapara itens da lei cujo não cumprimento comprometia a segurança do processamento seguro do PPS, ou baixa para itens que permitiam um tempo maior para adequação às exigências legais, sem comprometimento do processamento seguro do PPS.Posteriormente, a atribuição da gravidade foi validada por um grupo de 14 especialistas por meio da técnica Delphi, em duas rodadas.Resultados: Das 132 inconformidades referentes ao não cumprimento dos artigos da RDC ANVISA nº15/2012, julgou-se 108 inconformidades como gravidade alta referentes à infra-estrutura, aos equipamentos, aos processos de limpeza, de inspeção, de preparo, de acondicionamento, de desinfecção, de esterilização, de monitoramento da esterilização e do transporte, que poderiam comprometer a segurança do PPS, 105 validadas pela concordância acima de 70% dos juízes especialistas. Julgou-se como gravidade baixa 24 inconformidades; destas, 13 foram validadas, com consenso de mais de 70%, que se referiram à saúde ocupacional, à climatização, à estrutura física e aos equipamentos e 11 não obtiveram a concordância no percentual necessário para validação. Estes itens não validados referiram-se à climatização, à separação de áreas limpas e sujas, à desinfecção química, à qualidade da água de enxágue de PPS, à atribuição do CPPS e ao CME classe I processando materiais complexos. Conclusão: Para as 132 inconformidades referentes ao não cumprimento de 89 artigos da RDC ANVISA nº15/2012, validou-se 118 inconformidades quanto ao grau de gravidade atribuído 105 como gravidade alta e 13 como gravidade baixa. Das inconformidades elencadas como sendo de gravidade baixa, 11 não obtiveram a concordância no percentual necessário para validação. Evidenciou-se lacunas de conhecimento científico na área de processamento de produtos para saúde, como a influência do diferencial de pressão na área de limpeza de PPS como fator de segurança para os profissionais, e o efeito do desgaste/abrasão do PPS limpo com material abrasivo na facilitação da adesão de biofilmes. / Introduction: The existence of an important relationship between the use of products for health care and the occurrence of infections makes it a priority to establish effective measures for the processing of those that can be reused. The purpose of the Material and Sterilization Center (CME) is to provide safely processed, cleaned, disinfected or sterilized health products (PPS) free from biofilms, endotoxins, prion proteins and toxic substances, and still functionally effective . In Brazil, the CME has its Good Practices regulated by federal legislation of the National Sanitary Surveillance Agency since 03/15/2012 through the Resolution of the Collegiate Board of Directors (RDC) No. 15. The term of twenty-four (24) month, counted from the date of its publication for the CME to make the necessary adjustments, it can be inferred that many of the health services and processing companies covered by this Resolution have not been able to fully meet the legal requirements. Analyzing RDC ANVISA No. 15, not all items fit the same level of safety for the processed PPS, that is, in a sanitary inspection situation, nonconformities should not be considered with the same seriousness. The present analysis of the nonconformities of the Center of Material and Sterilization based on the ANVISA RDC nº15 / 2012 for severity validated by specialists can subsidize the CME manager in the prioritization of action plans with the Administration of the Health Establishment to make the service conform With current legislation. Objective: To analyze the nonconformities presented by CME, based on ANVISA RDC nº15 / 2012, to assess severity and to submit validation by specialists. Materials and methods: This was a methodological research, which consisted in the attribution of seriousness to 132 nonconformities in relation to the non-compliance of 89 items of DRC ANVISA nº 15/2012. High severity was assigned to items of law whose non-compliance compromised the security of PPS\'s secure processing, or lowering to items that allowed longer time to conform to legal requirements without compromising PPS\'s secure processing. Subsequently, the assignment of gravity was validated by a group of 14 specialists using the Delphi technique, in two rounds. Results: Of the 132 nonconformities related to the non-compliance of the articles of DRC ANVISA nº15 / 2012, 108 non-conformities were judged as \"high severity\" regarding infrastructure, equipment, cleaning, inspection, preparation, packaging , Disinfection, sterilization, sterilization and transport monitoring, which could compromise the safety of the PPS, validated by the agreement of more than 70% of the expert judges. It was judged as \"low gravity\" 24 nonconformities; Of these, 13 were validated, with a consensus of more than 70%, referring to occupational health, air conditioning, physical structure and equipment and 11 did not obtain agreement on the percentage required for validation. These items were not validated, they referred to the air conditioning, the separation of clean and dirty areas, the chemical disinfection, the quality of the rinsing water of PPS, the assignment of CPPS and the CME class I processing complex materials. Conclusion: For the 132 nonconformities regarding non-compliance with 89 articles of the ANVISA RDC nº15 / 2012, 118 nonconformities were validated regarding the degree of severity attributed - 105 as high severity and 13 as low severity. Of the nonconformities listed as being of low severity, 11 did not obtain the agreement in the percentage necessary for validation. There was evidence of gaps in scientific knowledge in the area of health products processing, such as the influence of the pressure differential in the PPS cleaning area as a safety factor for professionals, and the wear / abrasion effect of clean PPS with abrasive material In facilitating biofilm adhesion.