• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 613
  • 28
  • 28
  • 28
  • 27
  • 18
  • 10
  • 9
  • 8
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 636
  • 174
  • 159
  • 104
  • 66
  • 62
  • 60
  • 54
  • 54
  • 50
  • 48
  • 48
  • 44
  • 41
  • 41
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Desempenho de uma torre multiestágios para um dessalinizador controlado a energia elétrica / Multistage tower performance for a desalinator controlled by eletric energy

Araújo, Felipe Alves Albuquerque 16 February 2016 (has links)
ARAÚJO, F. A. A. Desempenho de uma torre multiestágios para um dessalinizador controlado a energia elétrica. 2016. 117 f. Dissertação (Mestrado em Engenharia Mecânica) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2016. / Submitted by Hohana Sanders (hohanasanders@hotmail.com) on 2016-06-15T12:45:41Z No. of bitstreams: 1 2016_dis_faaaraujo.pdf: 4586236 bytes, checksum: 75185da6a3b87bf8de85be3f4c88f087 (MD5) / Approved for entry into archive by Marlene Sousa (mmarlene@ufc.br) on 2016-07-11T14:18:38Z (GMT) No. of bitstreams: 1 2016_dis_faaaraujo.pdf: 4586236 bytes, checksum: 75185da6a3b87bf8de85be3f4c88f087 (MD5) / Made available in DSpace on 2016-07-11T14:18:38Z (GMT). No. of bitstreams: 1 2016_dis_faaaraujo.pdf: 4586236 bytes, checksum: 75185da6a3b87bf8de85be3f4c88f087 (MD5) Previous issue date: 2016-02-16 / Solar desalination plants are used for water treatment using solar radiation as an energy source, but its incidence varies, either in terms of time, the weather, the seasons or the presence of clouds. These factors complicate the understanding of the process variables influence and constructive geometric parameters. In this work, the experimental results, obtained by operation with a thermal desalination unit with heat recovery, are presented. The process occurs by controlled heating, by electricity flowing through a resistance present at the base of desalination tower (storage tank). In addition to the tank, the tower also comprises stages, consisting of polyurethane profiles, to prevent heat loss to the external environment, and aluminum trays in W format, through which flows the water generated by the steam condensation from the next lower stage. On the sides of each stage profiles, there are condensate collection gutters connected to hoses that lead the produced fluid to collection canisters. The production of desalinated water, with the use of a hydrophobic film on the bottom of the aluminum trays, where the condensate drains, was evaluated. Also biological, physical and chemical, chromatographic and spectrometric tests were conducted in order to verify the quality of the water produced. The best desalinator operating condition of the study, with the maximum output gain ratio (GOR) for the system of 7.92, was obtained with a potential difference of 120V, 600W power and five stages in the desalination tower. The film did not increase the water production, but it was also not observed contamination of water samples by the hydrophobic product. / Dessalinizadores solares são empregados para tratamento de água utilizando-se a radiação solar como fonte de energia, porém sua incidência varia, seja em função do horário, do clima, das estações do ano ou da presença de nuvens, o que dificulta o conhecimento da influência das variáveis de processo e dos parâmetros geométricos construtivos. Nesta dissertação, os resultados experimentais, obtidos através de operação com um dessalinizador térmico, com recuperação de calor, são apresentados. O processo ocorre por meio de aquecimento controlado, através de energia elétrica que passa por uma resistência presente na base da torre de dessalinização (tanque de armazenamento). Além do tanque, a torre também é composta por estágios, que consistem em perfis de poliuretano, para evitar a perda de calor com o meio externo, e bandejas de alumínio, em formato de W, por onde escoa a água gerada pela condensação do vapor proveniente do estágio imediatamente inferior. Nas laterais dos perfis de cada estágio, existem calhas de coleta do condensado, ligadas a mangueiras que conduzem o líquido produzido a vasilhas de coleta. Avaliou-se a produção de água dessalinizada com o uso de uma película hidrofóbica, na parte inferior das bandejas de alumínio, por onde o condensado escoa. Também foram realizados testes biológicos, físico-químicos, cromatográficos e espectrométricos, a fim de verificar a qualidade da água produzida. A melhor condição de operação do dessalinizador em estudo, com máxima Razão de Ganho de Saída (GOR) para o sistema, de 7,92, foi obtida com uma diferença de potencial de 120V, potência de 600W e cinco estágios na torre de dessalinização. A película não aumentou a produção de água, mas também não foi constatada contaminação das amostras de água pelo produto hidrofóbico.
42

Avaliação econômica dos tratores florestais Harvester e Forwarder / Economic evaluation of forest tractors Harvester and Forwarder

Silva, Remo Macieira Figueiredo 24 February 2015 (has links)
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2016-03-09T11:53:15Z No. of bitstreams: 1 texto completo.pdf: 964563 bytes, checksum: 5ce1a842437d8851e896cda321870671 (MD5) / Made available in DSpace on 2016-03-09T11:53:15Z (GMT). No. of bitstreams: 1 texto completo.pdf: 964563 bytes, checksum: 5ce1a842437d8851e896cda321870671 (MD5) Previous issue date: 2015-02-24 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Neste trabalho objetivou-se avaliar economicamente os tratores florestais harvester e forwarder nas atividades de corte e extração de eucalipto. Foram utilizadas quatorze máquinas florestais, oito harvesters da marca Komatsu, modelo PC-228 utilizados na derrubada e processamento da madeira e seis forwarders da marca Komatsu, modelo 890.3 utilizados na extração da madeira. A base de dados utilizada foi fornecida por uma empresa florestal situada no estado de Minas Gerais, contendo todas as informações necessárias para o cálculo do custo operacional das máquinas, a análise de sensibilidade, o ponto de equilíbrio, o custo anual equivalente (CAE) e a taxa interna de retorno (TIR). O custo operacional foi obtido através do somatório dos custos fixos e variáveis. Para a análise de sensibilidade foi realizada uma variação de ± 20% (10% para mais e 10% para menos) dos elementos mais representativos do custo total da máquina. O ponto de equilíbrio foi utilizado para determinar a quantidade de horas mínimas que as máquinas deveriam trabalhar para viabilizar sua compra. O CAE foi utilizado para determinar o ponto de troca do trator e a TIR foi utilizada para determinar a rentabilidade da operação. Os resultados obtidos para o custo total médio do sistema de toras curtas constituído pelo módulo de colheita harvester e do forwarder foi de US$ 255,71 h -1 e US$ 199,82 h -1 respectivamente. A redução de 10% dos custos com manutenção e reparos, mão de obra, combustível e depreciação resultou em uma economia de 9,36% do harvester e de 9,06% do forwarder. Estes elementos representaram aproximadamente 88% do custo total do harvester e 90% do custo total do forwarder. Somente para os anos de 2010 e 2011 foi encontrado o ponto de equilíbrio para os tratores florestais, sendo que para esses anos somente o harvester apresentou horas de trabalho suficiente para viabilizar a sua compra. Não foi encontrado o ponto de troca do harvester e forwarder. Para ambas as máquinas avaliadas não foi encontrada a TIR. / In this work aimed to evaluate economically the harvester and the forwarder in activities cutting and extraction of eucalyptus. Were used fourteen forest machines, eight harvesters of brand Komatsu, model PC-228 used in overthrow and processing of wood and six forwarders of brand Komatsu, 890.3 model used in the extraction of timber. The database used was provided by a forestry company located in the state of Minas Gerais, containing all the information necessary for calculating the operating cost of the machines, the sensitivity analysis, the breakeven point, the equivalent annual cost (CAE) and the rate internal of return (TIR). The operating cost was obtained by the sum of the fixed and variable costs. To analysis sensitivity held was a variation ± 20% (10% for more and 10% for less) of the most representative elements of the total cost of the machine. The breakeven point was used to determine the amount of minimum hours that the machines should work to enable your purchase. The CAE was used to determine the change point tractor and the TIR was used to determine the profitability of the operation. The results obtained for the average total cost of system of short log compound by the harvester harvesting module and the forwarder was US $ 255.71 h -1 and US $ 199.82 h -1 respectively. The reduction of 10% of the costs for maintenance and repairs, labor, fuel and depreciation resulted in a saving of 9.36% of the harvester and of 9.06% of forwarder. These elements represented approximately 88% of the total cost of the harvester and 90% of the total cost of the forwarder. Only for the years 2010 and 2011 found the balance point for forest tractors, to those years only the harvester obtained hours of work enough to enable your purchase. Not was found the exchange point of harvester and forwarder. For both assessed machines was not found TIR.
43

Caracterização de pulverizadores para aplicação de defensivos agrícolas na cultura do café / Sprayers characterization for pesticide application in the coffee culture

Paixão, Gefferson Pereira da 28 March 2016 (has links)
Submitted by Reginaldo Soares de Freitas (reginaldo.freitas@ufv.br) on 2016-09-14T12:09:07Z No. of bitstreams: 1 texto completo.pdf: 902329 bytes, checksum: 19897f436f9e8e082d93ad48b1ef80d2 (MD5) / Made available in DSpace on 2016-09-14T12:09:08Z (GMT). No. of bitstreams: 1 texto completo.pdf: 902329 bytes, checksum: 19897f436f9e8e082d93ad48b1ef80d2 (MD5) Previous issue date: 2016-03-28 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / A menor eficiência proporcionada pelos pulverizadores tradicionais utilizados nas aplicações de produtos fitossanitários em cafeicultura de montanha, caso do costal manual e motorizado ou mesmo os estacionários com lanças acopladas, tem refletido no aumento da repetibilidade das aplicações, podendo apresentar maiores riscos de intoxicação do aplicador e contaminações ambientais. Diante do exposto, novas tecnologias e/ou adaptações de técnicas de aplicação já utilizadas em outras culturas, necessitam ser estudadas a fim de proporcionar aplicações com maior eficiência, ou seja, visando a colocação correta do produto biologicamente ativo no alvo, em quantidade necessária, de forma econômica e com o mínimo de contaminação. Objetivou-se, com esse trabalho, caracterizar dois pulverizadores, um costal pneumático motorizado (Atomizador) e um estacionário com barra porta bicos vertical (“Foguetinho”), para aplicação de produtos fitossanitários em café. A caracterização do espectro de gotas produzido pelos equipamentos foi realizada com auxílio do analisador de partículas em tempo real (Spraytech, Malvern Instruments Co.), sendo adotado como parâmetros, o diâmetro da mediana volumétrica (DMV) e a porcentagem do volume pulverizado com gotas de diâmetro inferior a 100 μm (%V<100 μm). Na ocasião os equipamentos foram regulados para a produção de gotas na classe fina (DMV 100 -175 μm). Na etapa de campo, os experimentos foram conduzidos no delineamento em blocos ao acaso (DBC), em esquema de parcelas sub-subdivididas com oito repetições, sendo a parcela representada por três alturas na planta (terços superior, médio e inferior), a subparcela por dois quadrantes (frontal e lateral) e a sub-subparcela por três profundidades (externa, mediana e interna). Dentre os parâmetros avaliados na caracterização dos pulverizadores, a densidade de gotas depositadas (gotas cm-2), as porcentagens de área coberta foram mensuradas por meio da análise das etiquetas de papeis hidrossensíveis distribuídas em todos os níveis dos fatores estudados, as quais, após a pulverização com água mais corante traçador, foram retiradas, digitalizadas e analisadas pelo software “GOTAS”. Para quantificar o parâmetro deposição (μL cm-2), ou seja, a quantidade do produto retido no alvo, coletou-se três folhas em cada tratamento e após serem lavadas, determinou-se as absorbâncias das soluções por espectrofotometria de absorção molecular. Na análise da densidade de gotas (gotas cm-2), o atomizador foi eficiente, independente da parte avaliada, sendo recomendado para aplicações que demandam maior distribuição da calda, característica dos produtos com ação de contato. Já o foguetinho apresentou, nas condições avaliadas, características favoráveis para aplicações de produtos fitossanitários de ação sistêmica. Os dois equipamentos proporcionaram maiores valores de depósito e cobertura nas partes externas do quadrante frontal das plantas, e os maiores valores observados para o foguetinho, são atribuídos ao volume de calda, 540 L ha-1, em relação à 261 L ha-1 utilizados com o atomizador. / The lower efficiency provided by traditional sprayers used in pesticides applications in mountain coffee, manual and motorized knapsack or even stationary with coupled spears, has reflected in increasing of the applications, resulting in higher risks of environmental contamination and intoxication of the applicator. Therefore, new technologies and/or adaptations of application techniques used in other cultures need to be studied in order to provide applications with greater efficiency, seeking the correct placement of biologically active product at the target, in sufficient quantity, economically and with minimal contamination. This study aimed to characterize the sprayers, pneumatic knapsack (atomizer) and stationary with vertical bar ("Foguetinho"), for the pesticides application in coffee. The droplet spectrum was performed using the particle analyzer in real time (SPRAYTECH, Malvern Instruments Co.) and the measured variables were volumetric median diameter (VMD) and the percentage of the volume sprayed with drops diameter less than 100 micrometers (% V <100 μm). At the time, the sprayers were adjusted to produce fine drops (DMV 100 -175 μm). The experiment was conducted in sub-subdivided parcel being in the parcel three heights on the coffee plants (upper, middle and lower thirds), in the subparcel two quadrants (front and side) and in the sub-subparcel three depths (external, median and internal) in randomized block experimental design with eight replications for the deposition, droplet density and coverage tests. The values of droplet density (drops cm-2) and coverage (%) were measured by analyzing the water sensitive paper labels distributed at all levels of the studied factors and after spraying from water with dye tracer, they were removed, scanned and analyzed by "GOTAS" software. To quantify the deposition (μL cm-2), were collected three leaves in each treatment and after being washed, the absorbance of solutions was determined by molecular absorption spectrophotometry. In analyzing the drop density, the atomizer was efficient, independent of the evaluated part of the plant, therefore, is recommended for applications requiring a greater distribution of the liquid spray, typical contact action with products. In the evaluated conditions, the “foguetinho” was favorable to application using systemic products. Both sprayers provided higher deposit and coverage on the external depths of the front quadrant. However, the highest values observed for the foguetinho are assigned to the spray volume 540 L h-1 with respect to the 261 L ha-1 used with the atomizer.
44

Desenvolvimento de um sistema de apoio à decisão na seleção de motoniveladoras para a execução de obras de terraplenagem e de pavimentação / Development of a system for decision support in the selection of motor graders to perform earthwork and paving

Soares, Maria Edjane da Silva 12 May 2015 (has links)
SOARES, M. E. S. Desenvolvimento de um sistema de apoio à decisão na seleção de motoniveladoras para a execução de obras de terraplenagem e de pavimentação. 2015. 81 f. Dissertação (Mestrado em Engenharia de Transportes) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2015. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2015-07-16T13:10:41Z No. of bitstreams: 1 2015_dis_messoares.pdf: 3433520 bytes, checksum: c8b7f05963b73c300b7d7c1a4cd5145e (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2015-07-17T14:07:22Z (GMT) No. of bitstreams: 1 2015_dis_messoares.pdf: 3433520 bytes, checksum: c8b7f05963b73c300b7d7c1a4cd5145e (MD5) / Made available in DSpace on 2015-07-17T14:07:22Z (GMT). No. of bitstreams: 1 2015_dis_messoares.pdf: 3433520 bytes, checksum: c8b7f05963b73c300b7d7c1a4cd5145e (MD5) Previous issue date: 2015-05-12 / The demands on speed and efficiency of infrastructure design and construction has increased due to the use of software and more productive equipment, which has required better performance of equipment planners at each step. However, even considering that the costs associated with equipment are one of the items with the greatest weight in road construction, there are few computerized systems for fleet selection decision support. Fleet selection systems have been developed by researchers in Brazil and worldwide, but most of them consider only trucks and excavators/loaders or scrapers. This research aims at developing a decision support system for the selection of motor graders for construction activities involving earthmoving and paving works named SADPATROL. Initially, an analysis of the motor grader technological evolution was performed in order to evaluate the influence of the improvements on productivity gains. The equations presented in the literature were studied for productivity calculation and, after verifying the suitability of the equation, the equation was incorporated in the SADPATROL system with the necessary changes in its variables. Through the analysis of the variables in the equation, it was possible to identify how they influenced the productivity. Through this analysis, improvements were implemented. These improvements consisted of the inclusion of standard values for the system variables, allowing the achievement of more accurate results if the user has no data for productivity measured in the field. The SADPATROL system has 46 types of motor graders included in its database, from many different models and sizes and from 12 different manufacturers. The user is able to plan the fleet with its own equipment and verify if it satisfies the construction project deadline. If the deadline cannot be satisfied using the available fleet or the user has no equipment, the system performs the construction planning using all database equipment and provides the optimal solution with 46 options organized into fleets in increasing order according to the amount of equipment needed. It is also possible for the user to select the equipment using time cost information and, thus, achieve the lowest cost fleet. The significant amount of information necessary for motor graders selection and its inter-relationships and dependencies were organized in a systematic way in the SADPATROL system, reducing, the empiricism and the dependence on human expertise in selecting fleets. This research may also help in assisting in the development of technical standards and expanding the dissemination of knowledge about such equipment / A velocidade de concepção e de execução das infraestruturas tem aumentado devido à utilização de softwares e equipamentos eficientes, o que tem exigido um melhor desempenho de cada etapa. No entanto, apesar dos custos envolvidos com equipamentos serem os itens de maior peso na construção rodoviária, poucos são os sistemas existentes de apoio à decisão para a seleção das frotas. Propostas de seleção de frotas têm sido elaboradas por pesquisadores no Brasil e no mundo, porém a maioria consideram apenas caminhões e escavadeiras/carregadeiras ou scrapers. Este trabalho tem como objetivo desenvolver um sistema de apoio à decisão na seleção de motoniveladoras para a execução de obras de terraplenagem e de pavimentação, denominado SADPATROL. Inicialmente, foi feita uma análise da evolução tecnológica do equipamento motoniveladora visando verificar a influência destas melhorias sobre o aumento da produtividade. Foram analisadas as equações existentes na literatura para o cálculo de produtividade e após verificada a representatividade da equação utilizada no país esta foi escolhida para compor o SADPATROL, com as devidas alterações em suas variáveis. Através da análise de cada variável da equação foi possível identificar o quanto as mesmas influenciavam no resultado da produção desta forma, foram implementadas melhorias, como a inserção de valores padrões para as variáveis do sistema, permitindo a obtenção de resultados mais precisos, caso o usuário não possua dados medidos em campo. O SADPATROL possui cadastrado em seu banco de dados 46 tipos de motoniveladoras, dos mais variados modelos e tamanhos, de 12 fabricantes distintos. É possibilitado ao usuário calcular a frota com equipamentos próprios e verificar se esta atende ao prazo da obra. Caso o prazo não seja atendido pela frota própria ou o usuário não possua equipamentos, o sistema executa as informações da obra para todos os equipamentos do banco de dados e fornece a solução com as 46 opções organizadas em frotas, em ordem crescente de quantidade de equipamento. É possibilitado ainda selecionar os equipamentos nos quais se possui informação de custo horário, para assim obter a frota de menor custo. Toda a multiplicidade de informações necessárias à seleção de motoniveladoras, e suas inter-relações e dependências, foram organizadas de forma sistêmica no software SADPATROL, diminuindo assim o empirismo e a dependência da experiência humana na seleção de frotas. A presente pesquisa pode ainda contribuir para auxiliar a elaboração de normas técnicas e para a disseminação do conhecimento sobre o referido equipamento
45

Confiabilidade das determinações de localizadores eletrônicos foraminais : estudos ex vivo e in vivo / Reliability of electronic foramen locators determinations: an ex vivo and in vivo studies

Vasconcelos, Bruno Carvalho de January 2011 (has links)
VASCONCELOS, Bruno Carvalho de. Confiabilidade das determinações de localizadores eletrônicos foraminais : estudo ex vivo e in vivo. 2011. 75 f. Tese (Doutorado em Odontologia) - Universidade Federal do Ceará. Faculdade de Farmácia, Odontologia e Enfermagem, Fortaleza, 2011. / Submitted by denise santos (denise.santos@ufc.br) on 2011-12-19T14:00:58Z No. of bitstreams: 1 2011_tese_bcvasconcelos.pdf: 3716071 bytes, checksum: 2b0ddc172787a89bd79594b85e11f344 (MD5) / Approved for entry into archive by Eliene Nascimento(elienegvn@hotmail.com) on 2012-02-02T16:16:39Z (GMT) No. of bitstreams: 1 2011_tese_bcvasconcelos.pdf: 3716071 bytes, checksum: 2b0ddc172787a89bd79594b85e11f344 (MD5) / Made available in DSpace on 2012-02-02T16:16:39Z (GMT). No. of bitstreams: 1 2011_tese_bcvasconcelos.pdf: 3716071 bytes, checksum: 2b0ddc172787a89bd79594b85e11f344 (MD5) Previous issue date: 2011 / The electronic foramen locators (EFLs) currently available are based on different methods for determination of the distance between the apical foramen and a coronal reference, consequently presenting the real root canal length. Each of these methods aim to offer greater precision while presenting lower sensitivity to potential interferences found in the root canal system. With this in mind, the goal of this work was to evaluate the precision of some of these EFLs ex vivo and in vivo for electronic measurement of the root canal length at two different positions (0.0 mm and -1.0 mm) and under clinical conditions, respectively. In the ex vivo study, 42 mandibular bicuspids had their actual lengths compared to electronic measurements performed by the following EFLs: Root ZX, Mini Apex Locator, Propex II, iPex, and RomiApex A-15. Initial measurements were performed to positions identified by the devices as 1.0 mm short of the apical foramen (AF), and subsequent measurements were at the AF (0.0 mm). For the in vivo study, ten patients with bicuspids referred for extraction as part of their orthodontic clinical planning had electronic root length measurements using two EFLs, Propex II and Root ZX, prior to extraction. The last files used were fixated to the teeth, which were then extracted. Then, the apical 4 mm of the canals were exposed to allow assessment of the distance between the tip of the file and the AF. The percentages of precision from the ex vivo electronic measurements at 0.0 mm and -1.0 mm considering each device were: 70.6% and 47.1% (Root ZX); 61.8% and 52.9% (Mini Apex Locator); 67.6% and 38.2% (Propex II); 61.8% and 38.2% (iPex); and 73.5% and 38.2% (RomiApex A-15), respectively (±0.5 mm). Statistical differences were observed for Propex II, iPex, and RomiApex A-15 when measurements at both positions were compared (0.0 mm X -1.0 mm). No significant differences between the EFLs were observed at 0. 0 mm. However, at -1.0 mm, the precision of iPex was statistically lower compared with the other devices. Regarding the in vivo study, the AF was located in 75% (Root ZX) and 66.7% of the teeth (Propex II), under a tolerance margin of ±0.5 mm. Statistically significant differences were observed between the two EFLs. Based on the results obtained and considering the conditions of this work, it was concluded that EFLs are reliable tools for determining the real length of the canal, but are not infallible. It was also observed in the ex vivo experiments that all EFLs had decreased precision in measurements with the instruments short of the AF, with significant differences observed between Propex II, iPex, and RomiApex A-15. Moreover, it was concluded that under clinical conditions, Root ZX was more reliable than Propex II. / Os localizadores eletrônicos foraminais (LEFs) disponíveis atualmente utilizam diversos métodos de determinação eletrônica da posição foraminal, qual seja a medida entre o forame apical e uma referência incisal/oclusal, definindo consequentemente o comprimento do canal radicular. Cada um desses métodos procura oferecer maior precisão e menor sensibilidade a possíveis interferências no sistema de canais radiculares. Desta forma, procurou-se avaliar a precisão de alguns destes LEFs ex vivo e in vivo na realização de odontometrias eletrônicas em diferentes posições (0,0 mm e -1,0 mm) e em condições de uso clínico, respectivamente. No estudo ex vivo, 42 pré-molares inferiores tiveram seus comprimentos reais comparados a odontometrias eletrônicas realizadas com os LEFs Root ZX, Mini Apex Locator, Propex II, iPex e RomiApex A-15. Inicialmente, em função dos displays dos aparelhos, determinaram-se medições 1,0 mm aquém do forame apical (FA), e posteriormente as medições no FA. Para o estudo in vivo, dez pacientes que apresentavam pré-molares com indicação de exodontia como parte de seus planejamentos clínicos ortodônticos tiveram odontometrias eletrônicas realizadas com os LEFs Propex II e Root ZX previamente a exodontia. Os últimos instrumentos utilizados foram fixados aos dentes que foram então extraídos e tiveram 4,0 mm apicais de suas raízes expostos e analisados quanto à distância entre as pontas dos instrumentos e os FA. No estudo ex vivo, considerando as medições realizadas por cada um dos aparelhos a 0,0 mm e a -1,0 mm, a precisão dos LEFs foi: 70,6% e 47,1% (Root ZX), 61,8% e 52,9% (Mini Apex Locator), e 67,6% e 38,2% (Propex II), 61,8% e 38,2% (iPex), e 73,5% e 38,2% (RomiApex A-15), respectivamente (±0,5 mm). Diferenças estatísticas foram encontradas para o Propex II, iPex e RomiApex A-15, quando comparadas suas leituras nas duas posições (0,0mm X -1,0 mm). Não foram encontradas diferenças entre os LEFs a 0,0 mm, porém, a -1,0 mm o iPex foi estatisticamente inferior aos demais. Já no estudo in vivo, o FA foi localizado em 75% (Root ZX) e 66,7% (Propex II), considerando margem de ±0,5 mm, tendo sido encontrada diferença estatisticamente significante entre os LEFs. Diante do exposto, nas condições do estudo, pode-se concluir que os LEFs são ferramentas confiáveis na determinação de comprimentos reais, todavia, não são infalíveis; que em condições ex vivo, quando mantidos aquém do FA, todos os LEFs reduziram sua precisão, tendo o Propex II, iPex e RomiApex A-15 apresentado diferenças significantes; e que em condições de uso clínico, o Root ZX apresentou maior confiabilidade do que o Propex II.
46

Analise de viabilidade para o projeto de poltronas de passageiros para a aviação regional

Cybis, Walter January 1988 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina. Centro Tecnologico / Made available in DSpace on 2016-01-08T16:02:19Z (GMT). No. of bitstreams: 1 83272.pdf: 18752823 bytes, checksum: 6e80ff46edd3bc9baef581ccab061608 (MD5) Previous issue date: 1988 / Aproveitou-se uma experiência profissional na indústria de poltronas de passageiros para a aviação comercial para formar a base de uma investigação sobre a etapa de Análise de Viabilidade para o projeto de produtos. Constam deste trabalho a análise do mercado e suas necessidades, a análise das soluções técnicas dos produtos concorrentes, o estudo de uma oportunidade tecnológica e o estudo de viabilidade das soluções alternativas geradas para o projeto.
47

Otimização de periodicidade nos planos de manutenção preventiva

Corrêa, Rodrigo Fernandes January 2015 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Mecânica, Florianópolis, 2015. / Made available in DSpace on 2016-04-19T04:20:24Z (GMT). No. of bitstreams: 1 337628.pdf: 13714420 bytes, checksum: 8668532b393dce338ee270e553416576 (MD5) Previous issue date: 2015 / Várias estratégias de manutenção são empregadas nos complexos industriais, tendo, como destaque, modelos de gestão que buscam ações preventivas, como TPM (Total Productive Maintenance), RCM (Reliability Centered Maintenance), e outras preventivas baseadas na condição, no tempo, em paradas, dentre outras. Ao aprofundar este tema, tanto do ponto de vista do planejamento quanto da aplicação, percebe-se que o grande desafio para otimização do custo dessas estratégias está em  o que fazer e  quando fazer ; ou seja, qual escopo e com que periodicidade. Observa-se, no contexto industrial, que há conhecimento das equipes de manutenção em avaliar o comportamento das falhas, definir a vida útil dos principais sistemas que compõem os processos, programar todas as necessidades de reparo e controlar as paradas de um processo. Contudo, percebe-se que há limites em relação à previsão de periodicidade ótima, devido à grande complexidade de combinações possíveis de escopo e momento ideal para a parada de um processo. Esta percepção motivou o presente estudo, para o qual se traçou o objetivo de desenvolver um modelo matemático que otimizasse os custos de manutenção, por meio do estudo da vida útil dos sistemas, fundamentados pelo uso, tempo, condição e custos. A modelagem matemática utilizada foi implementada computacionalmente por meio do MATLAB®. Assim, foi possível analisar o comportamento das variáveis envolvidas na otimização da periodicidade, o custo residual por troca prematura, a periodicidade ótima, o escopo, os custos com manutenção corretiva/preventiva, o tempo de parada de processo e a identificação dos sistemas significativos para aplicação de projeto e para dimensionamento da vida útil dentro do conceito RCM. Para aplicar o modelo, foi desenvolvida uma metodologia que auxilia o usuário durante as simulações com a utilização da ferramenta computacional. A análise foi aplicada numa empresa da indústria cerâmica de grande porte, composta de mais de 43 processos com 5.000 ativos. Para as simulações foram utilizadas linhas de processo contínuo e equipamentos; contudo, a sistemática poderá ser utilizada em empresas de outros setores industriais.<br> / Abstract : Several maintenance strategies are introduced in the industrial environment and as a highlight management models that seek preventive actions such as TPM (Total Productive Maintenance), RCM (Reliability Centered Maintenance), in other preventive based on the condition, time, Turnaround, them others. Deepening this topic from the point of view of planning as the application, it is clear that the challenge to optimize the cost of these strategies is "what to do" and "when to do it", that is, what scope and which periodicity. It is observed in the industrial context, there is knowledge of the maintenance teams to evaluate the behavior of faults; in defining the useful life of the major systems that compose the processes; to schedule all repairs needs and control downtime of a process. However, we realized that there are limits on the optimal periodicity of prevision due to the great complexity of possible combinations of scope and ideal time to stop a process. This perception has motivated this study by which traced the objective of developing a mathematical model that optimizes maintenance costs through the lifetime of the study of systems, justified by used, time, condition and costs. Mathematical model was implement computationally in MATLAB®. It was possible to analyze the behavior of the variables involved in the optimization of periodicity, the residual cost for premature replacement, the optimal periodicity, scope, costs of corrective/preventive maintenance, process downtime and identification of systems that are important for project implementation and scaling of lifetime within the RCM concept. It was developed a methodology that assists the user during simulations. The analysis was applied to a large company industry, made up of more than 43 processes with 5000 assets. The lines and equipment were used for the simulations.
48

Tecnologia assistiva

Mattozo, Tiago Raijche January 2016 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Comunicação e Expressão, Programa de Pós-Graduação em Design e Expressão Gráfica, Florianópolis, 2016. / Made available in DSpace on 2016-09-20T04:51:33Z (GMT). No. of bitstreams: 1 340717.pdf: 3144287 bytes, checksum: 2abbc948b53e2b6b47122cdb7f0aa47f (MD5) Previous issue date: 2016 / Segundo dados da Organização das Nações Unidas 10% da população mundial vive com alguma deficiência. Dados do Instituto Brasileiro de Geografia e Estatística indicam que o Brasil possui mais de quarenta e cinco milhões de cidadãos com algum tipo de deficiência (23,9% da população). Ou seja, praticamente um quarto da população brasileira demanda algum recurso de Tecnologia Assistiva. Especialmente nos últimos quinze anos, o Brasil evoluiu consideravelmente na atenção e suporte às pessoas com deficiência. Contudo, apesar destes significativos avanços, o Brasil ainda está algumas décadas atrasado em relação a outros países. O objetivo desta pesquisa foi identificar os Requisitos do Produto para órteses de membros inferiores a partir das percepções dos usuários. Para tal, investigou-se as necessidades dos usuários, para que estas pudessem ser convertidas em Requisitos dos Usuários e estes em Requisitos do Produto. Através de visitas técnicas a empresas e organizações especializadas na confecção de órteses, juntamente com a aplicação de questionários aos usuários, foi realizado um levantamento que indicasse quais são os requisitos mais importantes, segundo a percepção dos usuários. O questionário aplicado foi o QUEST 2.0 (Quebec User Evaluation of Satisfaction with assistive Technology). O instrumento de coleta, avalia doze aspectos, sendo oito relativos aos recursos (1.Dimensões, 2.Peso, 3.Facilidade de ajuste, 4.Segurança, 5.Durabilidade, 6.Facilidade de uso, 7.Conforto, 8.Eficácia) e quatro relacionados aos serviços associados (9.Processo de entrega, 10. Assistência técnica, 11.Serviços profissionais e 12.Serviços de acompanhamento). Em função do objetivo principal desta pesquisa, foi depositada maior atenção aos oito primeiros aspectos. Ainda que a média final de satisfação dos usuários tenha atingido um valor mediano para avançado (3,82), as variações entre os participantes, bem como os comentários complementares registrados, expõem uma variada lista de necessidades não contempladas. Quantitativamente, os aspectos Conforto, Segurança, Peso e Durabilidade foram aqueles que propiciaram o maior volume de problemas registrados. Ainda que se tenha definido uma hierarquia para os requisitos, vale ressaltar que todos os problemas registrados são muito importantes para os usuários. Dentre os problemas registrados, vale ressaltar aqueles ligados aos relatos de quadros de dor e surgimento de escaras. Certos usuários relataram momentos em que atingiam um nível insuportável de dor, fazendo com que abandonassem o uso da órtese, temporariamente ou mesmo por longos períodos. Estes casos evidenciam o grau de importância do desenvolvimento de melhorias nas órteses para membros inferiores. Oferecendo dados e informações, este estudo sugere alguns caminhos para a ampliação da inclusão das pessoas com deficiência em nossa sociedade, de forma plena e irrestrita. A pesquisa desenvolvida e relatada neste documento pode servir de embasamento para outros estudos futuros, visto que, após a definição dos Requisitos do Produto, o desenvolvimento estratégico de produto prevê a definição das Especificações de Projeto, assim como o Projeto de Produto propriamente dito.<br> / Abstract : According to the United Nations 10% of the world's population lives with a disability. Data from the Brazilian Institute of Geography and Statistics indicate that Brazil has more than forty-five million people with a disability (23.9% of the population). That is, nearly a quarter of the population takes some Assistive Technology feature. Especially in the last fifteen years, Brazil has evolved considerably in the care and support to people with disabilities. However, despite these significant advances, Brazil is still a few decades late compared to other countries. The objective of this research was to identify the product requirements for lower limb orthoses from the perceptions of users. To this end, were investigated the needs of users, so that they could be converted to User Requirements and these in Product Requirements. Through technical visits to companies and organizations specializing in orthosis, along with questionnaires to users, a survey was conducted to indicate what are the most important requirements, as perceived by the users. The questionnaire was the QUEST 2.0 (Quebec User Evaluation of Satisfaction with assistive Technology). The instrument evaluates twelve aspects, eight related to resources (1. Dimensions, 2. Weight, 3. Adjustment facility, 4. Safety, 5. Durability, 6. Ease of use, 7. Comfort, 8. Effectiveness) and four related to associated services (9. Delivery Process, 10. Technical assistance, 11. Professional services, and 12. Monitoring services). Based on the primary objective of this research it was dedicated more attention to the first eight aspects. Although the average end user satisfaction has reached a median for advanced (3.82), the variations between participants and registered further comment, expose a varied list of needs not covered. Quantitatively aspects Comfort, Safety, Weight and Durability were those that provided the bulk of recorded problems. Even if set a hierarchy of requirements, it is noteworthy that all registered issues are very important for users. Among the reported problems, it is worth mentioning those related to reports of pain cases and appearance of bedsores. Some users have reported times when they reached an unbearable level of pain, causing them to abandon the use of bracing, temporarily or for long periods. These cases show how important the development of improvements in orthoses for lower limbs. Providing data and information, this study suggests some ways to expand the inclusion of people with disabilities in our society, in full and without restrictions. The developed and research reported in this document can serve as a basis for other future studies, since, after the definition of product requirements, product development strategy provides for the definition of project specifications, as well as the product design itself.
49

Dispositivo médico assistencial para análise de turbidez do líquido peritoneal dialisado

Ferreira, Nilson Eduardo 23 November 2017 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade Gama, Programa de Pós-Graduação em Engenharia Biomédica, 2017. / Submitted by Raquel Almeida (raquel.df13@gmail.com) on 2018-03-12T18:55:37Z No. of bitstreams: 1 2017_NilsonEduardoFerreira.pdf: 4461261 bytes, checksum: d32571f7d507ec75f4f75c659fb5af11 (MD5) / Rejected by Raquel Viana (raquelviana@bce.unb.br), reason: Bom dia, Por favor, adeque o campo Orientador. Atenciosamente on 2018-03-15T12:54:37Z (GMT) / Submitted by Raquel Almeida (raquel.df13@gmail.com) on 2018-03-15T15:57:02Z No. of bitstreams: 1 2017_NilsonEduardoFerreira.pdf: 4461261 bytes, checksum: d32571f7d507ec75f4f75c659fb5af11 (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2018-03-15T18:09:24Z (GMT) No. of bitstreams: 1 2017_NilsonEduardoFerreira.pdf: 4461261 bytes, checksum: d32571f7d507ec75f4f75c659fb5af11 (MD5) / Made available in DSpace on 2018-03-15T18:09:24Z (GMT). No. of bitstreams: 1 2017_NilsonEduardoFerreira.pdf: 4461261 bytes, checksum: d32571f7d507ec75f4f75c659fb5af11 (MD5) Previous issue date: 2018-03-15 / A diálise peritoneal é um tratamento renal substitutivo cuja principal característica é a manutenção da qualidade de vida dos pacientes. Somente no Brasil, um crescente número de doentes renais é elegível para essa terapia e o grande desafio dos profissionais de saúde é a manutenção desses pacientes o maior tempo possível no tratamento. Neste estudo, propomos um Equipamento Médico-Assistencial para auxiliar aos profissionais de saúde no controle e monitoramento de marcadores negativos, como infecções e alterações biológicas, por meio da leitura e análise da turbidez do líquido dialisado. Como processo metodológico da pesquisa, a imersão no conhecimento do perfil das pessoas portadoras de insuficiência renal, em diálise peritoneal, foi necessária principalmente na avaliação da capacidade funcional desses doentes em conviver com o problema renal e tangenciá-los com recursos e mecanismos tecnológicos. As variáveis estatísticas demonstraram que, com o passar do tempo, com as limitações próprias da idade e pela condição de saúde fragilizada, muitos pacientes carecem de um apoio mais eficiente na percepção de sinais indicativos sobre a qualidade do líquido dialisado, ou a turbidez. Inferiu-se nos testes de hipótese que não há qualquer impacto da capacidade funcional face à doença renal, mesmo em casos extremos, no uso de controle eletrônico da turbidez sendo realizada por um dispositivo com as características do proposto no estudo. Os resultados obtidos com o dispositivo, comparados com os métodos de análises padrão do líquido de infusão peritoneal, demonstraram que os valores de turbidez medidas pelo equipamento proposto permitem avaliar as condições de turbidez do líquido peritoneal dialisado com maior acurácia do que o método tradicional, por percepção meramente visual. Nas análises, por meio da observação da absorbância pela técnica da espectrofotometria por emissão de luz visível, o valor de absorbância obtido para a substância de infusão peritoneal foi em torno de 0,001; já a média obtida nas análises do líquido dialisado pós terapia foi em torno de 0,17. Esses dados evidenciam a capacidade do dispositivo desenvolvido, tanto na realização dos testes in vitro quanto nos testes in vivo, cujos valores médios ficaram em 0,010 e 0,27 respectivamente. O dispositivo eletrônico desenvolvido a partir de componentes eletrônicos de fácil aquisição, e contando com mecanismos auxiliares como software de análise, base de dados para armazenamento e consulta online pela Web, compreendem um conjunto de ferramentas capazes de promover maior segurança na avaliação da turbidez do líquido peritoneal dialisado, uma análise mais precisa em seus níveis periódicos e, principalmente, a troca de informação permanente entre paciente e profissional de saúde, minimizando a demora em tomadas de decisão em saúde face à turbidez do líquido peritoneal dialisado. / Peritoneal dialysis is a substitutive renal treatment whose main characteristic is the maintenance of patients’ quality of life. In Brazil alone, a growing number of kidney patients are eligible for this therapy and the major challenge for healthcare professionals is to maintain these patients as long as possible in treatment. In this study, we propose a Medical Assistance Kit to assist health professionals in the control and monitoring of negative markers, such as infections and biological changes, by reading and analyzing the turbidity of the dialysed liquid. As a methodological process of the research, immersion in the knowledge of the profile of people with renal impairment in peritoneal dialysis was necessary mainly in the evaluation of the functional capacity of these patients to live with the renal problem and tangentiate them with technological resources and mechanisms. Statistical variables have shown that, over time, with age limitations and poor health status, many patients lack a more efficient support in the perception of indicative signals on the quality of the dialysed liquid or turbidity. We inferred hypothesis tests that there is no impact of functional capacity against renal disease, even in extreme cases, in the use of electronic turbidity control being performed by a device with the characteristics proposed in the study. The results obtained with the device, compared with the standard methods of peritoneal infusion liquid analysis, showed that the turbidity values measured by the proposed equipment allow to evaluate the turbidity conditions of the dialyzed peritoneal fluid more accurately than the traditional method, merely visual perception. In the analyzes, by observing the absorbance by the visible light emission spectrophotometry technique, the absorbance value obtained for the peritoneal infusion substance was around 0.001; the mean value obtained in the analysis of the dialysed liquid after therapy was around 0.17. These data demonstrate the ability of the device developed in both the in vitro and in vivo tests whose mean values were 0.010 and 0.27 respectively. The electronic device developed from easy-to-acquire electronic components, and having ancillary mechanisms such as analysis software, database for online storage and consultation by Web, comprise a set of tools capable of promoting greater safety in the evaluation of the turbidity of the dialyzed peritoneal fluid, a more accurate analysis in its periodic levels and, mainly, the exchange of permanent information between patient and health professional, minimizing the delay in health decision making in the face of turbidity of the peritoneal fluid dialysed.
50

SECTEM: sistema baseado na web de especificação e comparação técnica de equipamentos médicos registrados na Agência Nacional de Vigilância Sanitária / TCSME : web based system for especification and technical comparison of medical equipment registered in the National Sanitary Vigilance Agency

Ramirez Filho, Walter Lima 04 July 2016 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade Gama, Programa de Pós-Graduação em Engenharia Biomédica, 2016. / Submitted by Fernanda Percia França (fernandafranca@bce.unb.br) on 2016-08-26T21:06:58Z No. of bitstreams: 1 2016_WalterLimaRamirezFilho.pdf: 2865892 bytes, checksum: 0104b5032eb6f6b501dabcb61af57049 (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2016-09-20T20:25:50Z (GMT) No. of bitstreams: 1 2016_WalterLimaRamirezFilho.pdf: 2865892 bytes, checksum: 0104b5032eb6f6b501dabcb61af57049 (MD5) / Made available in DSpace on 2016-09-20T20:25:50Z (GMT). No. of bitstreams: 1 2016_WalterLimaRamirezFilho.pdf: 2865892 bytes, checksum: 0104b5032eb6f6b501dabcb61af57049 (MD5) / A criação de ferramentas computacionais para aperfeiçoar o cuidado em saúde e o atendimento à racionalização, sustentabilidade dos eventos clínicos, econômicos e sociais da saúde possibilita solucionar problemas decorrentes da má especificação na aquisição de Equipamentos Médicos (EMs) no contexto da saúde pública. No presente estudo foi proposto um Sistema de Especificação e Comparação Técnica de EMs (SECTEM) que auxilie profissionais técnicos da Engenharia Clínica (EC), Engenharia Biomédica, entre outros, em atender às solicitações clínicas, por meio da especificação técnica, em relação à compra de EMs para as Unidades de Saúde. Estimam-se, também neste trabalho, aspectos ainda não abordados pela literatura, quanto ao gerenciamento de tecnologias de saúde, à medida que se discutem os impactos qualitativos da saúde, quando lançado o processo de compra de EMs. O software foi elaborado pelo padrão Modelo, Visão e Controlador (MVC), isto é, em três camadas que permite o acompanhamento e a realização de vários pequenos ajustes durante o seu incremento. Os resultados evidenciaram que em meio à preocupação com o fator “cuidado de saúde”, assim como a efetividade da atuação de EMs, após a aquisição pelo parque tecnológico, a maioria (99%) dos achados científicos ainda é incipiente na proposição de uma ferramenta capaz de auxiliar na adequada condução das comparações e especificações efetuadas na atualidade. O SECTEM proposto foi capaz de empregar o indispensável conhecimento técnico para especificar e comparar as tecnologias de forma útil e simplificada para os profissionais de saúde. ________________________________________________________________________________________________ ABSTRACT / The creation of computational tools to improve health care and service rationalization, sustainability of clinical, economic and social events in healthcare allows solving problems arising from mismanagement in purchasing Medical Equipments (MEs) in the context of public health. In this work it was proposed a Technical Comparison System of MEs (TCSME) that helps technical professionals of Clinical Engineering (CE), Biomedical Engineering, among others, to meet clinical demands, through the technical specification, in relation to the purchase of MEs for Health Units. This work also estimates aspects not yet addressed by literature on the management of Health Technologies, as it discusses the qualitative impacts of health when launched the process of buying MEs. The results shows that amid concern with the "Health Care" factor, as well as with the effectiveness of MEs operation after its acquisition, the majority (99%) of scientific researchers are still incipient in proposing a tool which is able to help in the proper conduct of the comparisons and specifications made today. The proposed TCSME was able to apply the indispensable technical knowledge to specify and compare the technology in a simplified and useful way for healthcare professionals.

Page generated in 0.0575 seconds