Spelling suggestions: "subject:"escáner"" "subject:"escândalo""
1 |
Monitoramento e avaliação de processos erosivos marginais em reservatórios de usinas hidrelétricas por meio de varredura a laser / Monitoring and evaluation of riverbank erosion process in hidroeltric reservoir using laser scanningMoraes, Marcus Vinícius Antunes de [UNESP] 26 February 2016 (has links)
Submitted by Marcus Vinícius Antunes de Moraes null (antunesdemoraes@gmail.com) on 2016-04-08T12:40:38Z
No. of bitstreams: 1
MORAES_DISSERTACAO_FINAL.pdf: 6679623 bytes, checksum: 6da0abfa09050896a1e94b6554806d56 (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-04-08T17:32:33Z (GMT) No. of bitstreams: 1
moraes_mva_me_prud.pdf: 6679623 bytes, checksum: 6da0abfa09050896a1e94b6554806d56 (MD5) / Made available in DSpace on 2016-04-08T17:32:33Z (GMT). No. of bitstreams: 1
moraes_mva_me_prud.pdf: 6679623 bytes, checksum: 6da0abfa09050896a1e94b6554806d56 (MD5)
Previous issue date: 2016-02-26 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / As erosões marginais são causadas por uma série de fatores que impactam ou atenuam o processo, tais como o tipo de erosão, a constituição do solo, ventos, regime hidrológico, presença e tipo de vegetação, entre outros. Os processos de erosão marginal ocorrem às margens de corpos d’água e demandam estudos específicos para seu entendimento e possível mitigação. Os escâneres LASER (Light Amplification by Stimulated Emission of Radiation) móveis são indicados para o levantamento de dados para séries temporais, principalmente em áreas com alterações pequenas ao longo do tempo, em virtude de sua elevada resolução espacial e acurácia. Sistemas de escaneamento LASER dotados de posicionamento GNSS/RTK (Global Navigation Satellite System/Real Time Kinematic) têm a vantagem de demandar menos etapas de pós-processamento, uma vez que os resultados imediatos do levantamento são as nuvens de pontos prontas para edição, e com precisão compatível à do RTK. Neste trabalho apresenta-se uma proposta metodológica para a execução dos levantamentos com uso de sistema LASER móvel embarcado, pós-processamento dos dados, geração de produtos e análise dos resultados para fins de monitoramento de processos de erosão marginal. Experimentos para caracterização da acurácia dos levantamentos realizados com uso do escâner móvel MDL Dynascan M150 mostraram que a acurácia média dos levantamentos varia de 5 a 15 cm, conforme a distância da base RTK à área de levantamento. Ainda são apresentados resultados obtidos em um estudo de caso, que demonstram a eficiência da metodologia proposta. / River bank erosions are caused by a set of factors that affect or attenuate the process, such as type of erosion, constitution of the soil, and environmental factors such as wind, water regime, presence and type of vegetation, among others. Bank erosion processes occur on the banks of water bodies and require specific studies for their understanding and possible mitigation. Mobile LASER (Light Amplification by Stimulated Emission of Radiation) scanner systems are suitable to survey data to compose temporal series, mainly in areas with small changes over time, due to their high spatial resolution and accuracy. Laser scanning systems equipped with GNSS/RTK (Global Navigation Satellite System/Real Time Kinematic) positioning have advantage because demand less post-processing steps, since the immediate results of survey are point clouds ready for editing, and their accuracy is compatible with RTK accuracy. This work presents a methodology carrying out Mobile LASER surveys, post-processing data, product generation and analysis of results for monitoring purposes of river bank erosion processes. Experiments to characterize the accuracy of surveys conducted with the use of mobile laser scanner MDL DynaScan M150, show that mean accuracy of surveys vary from 5 to 15 cm according to the distance of RTK basis to survey area. Besides, are presented results of a case study that demonstrate the efficiency of the proposed methodology.
|
2 |
Microtomografia com Raio X e processamento de imagem na obtenção da porosidade do concreto / X Ray microtomography and image processing to obtain the concrete porosityJosé Renato de Castro Pessôa 23 February 2011 (has links)
Fundação de Amparo à Pesquisa do Estado do Rio de Janeiro / O objetivo principal desse trabalho foi utilizar métodos não destrutivos (END),
como a microtomografia com Raio X e técnicas de obtenção e processamento de
imagens, para obtenção da porosidade do concreto. Foram utilizados dois métodos.
Em um método as imagens foram obtidas por meio de microtomografia por Raio X e
no outro foi utilizado um escâner comercial para obtenção das imagens. Essas
imagens foram processadas por meio de técnicas de processamento de pixel e
morfologia matemática. Os resultados obtidos para a porosidade foram comparados
com resultado obtido por meio do método proposto pela NBR 9778 (2005)
(Absorção de água, índice de vazios e massa específica em argamassa e concreto
endurecido). As imagens microtomográficas das amostras de concreto foram obtidas
num sistema Skyscan 1172 com 256 tons de cinza, ajustadas em contraste,
binarizadas e filtradas. No outro método foi utilizado um Escâner Comercial com
resolução de 2400 dpi para adquirir as imagens, sendo também utilizadas técnicas
de processamento de pixel e morfologia matemática para processá-las. Os
resultados dos valores da porosidade mostraram compatibilidade entre os dois
métodos apresentados e o método proposto pela NBR 9778 (2005). Observou-se
que os resultados obtidos por microtomografia foram mais confiáveis, mas o método
utilizando o escâner comercial se apresentou como um método aceitável por seus
resultados e principalmente por seu baixo custo e facilidade de operação. / The main goal of this research was to use non-destructive methods (ND), like
the X Ray microtomography and techniques to acquire and process images, to
obtain the concrete porosity. There were presented two methods. In one of the
methods the images were acquired through X Ray microtomography and in the other
method there were used the commercial scanner to acquire the images. Those
images were processed using techniques of pixel processing and mathematical
morphology. The results to the porosity were compared with the result obtained
through the method proposed by NBR 9778 (2005) (Absorção de água, índice de
vazios e massa específica em argamassa e concreto endurecido). The
microtomographed images of the concrete samples were obtained using a Skyskan
1172 system with 256 gray levels, adjusted in contrast, binarized and filtered. In the
other method there were used a commercial scanner with 2400 dpi of resolution to
acquire the images, being also used techniques of pixel processing and
mathematical morphology to process them. The results have shown compatibility
between the two presented methods and the method presented by NBR 9778
(2005). It was observed that the results obtained by microtomography were more
reliable, but the method using the scanner is presented as an acceptable method for
their results and especially for its low cost and ease of operation.
|
3 |
Microtomografia com Raio X e processamento de imagem na obtenção da porosidade do concreto / X Ray microtomography and image processing to obtain the concrete porosityJosé Renato de Castro Pessôa 23 February 2011 (has links)
Fundação de Amparo à Pesquisa do Estado do Rio de Janeiro / O objetivo principal desse trabalho foi utilizar métodos não destrutivos (END),
como a microtomografia com Raio X e técnicas de obtenção e processamento de
imagens, para obtenção da porosidade do concreto. Foram utilizados dois métodos.
Em um método as imagens foram obtidas por meio de microtomografia por Raio X e
no outro foi utilizado um escâner comercial para obtenção das imagens. Essas
imagens foram processadas por meio de técnicas de processamento de pixel e
morfologia matemática. Os resultados obtidos para a porosidade foram comparados
com resultado obtido por meio do método proposto pela NBR 9778 (2005)
(Absorção de água, índice de vazios e massa específica em argamassa e concreto
endurecido). As imagens microtomográficas das amostras de concreto foram obtidas
num sistema Skyscan 1172 com 256 tons de cinza, ajustadas em contraste,
binarizadas e filtradas. No outro método foi utilizado um Escâner Comercial com
resolução de 2400 dpi para adquirir as imagens, sendo também utilizadas técnicas
de processamento de pixel e morfologia matemática para processá-las. Os
resultados dos valores da porosidade mostraram compatibilidade entre os dois
métodos apresentados e o método proposto pela NBR 9778 (2005). Observou-se
que os resultados obtidos por microtomografia foram mais confiáveis, mas o método
utilizando o escâner comercial se apresentou como um método aceitável por seus
resultados e principalmente por seu baixo custo e facilidade de operação. / The main goal of this research was to use non-destructive methods (ND), like
the X Ray microtomography and techniques to acquire and process images, to
obtain the concrete porosity. There were presented two methods. In one of the
methods the images were acquired through X Ray microtomography and in the other
method there were used the commercial scanner to acquire the images. Those
images were processed using techniques of pixel processing and mathematical
morphology. The results to the porosity were compared with the result obtained
through the method proposed by NBR 9778 (2005) (Absorção de água, índice de
vazios e massa específica em argamassa e concreto endurecido). The
microtomographed images of the concrete samples were obtained using a Skyskan
1172 system with 256 gray levels, adjusted in contrast, binarized and filtered. In the
other method there were used a commercial scanner with 2400 dpi of resolution to
acquire the images, being also used techniques of pixel processing and
mathematical morphology to process them. The results have shown compatibility
between the two presented methods and the method presented by NBR 9778
(2005). It was observed that the results obtained by microtomography were more
reliable, but the method using the scanner is presented as an acceptable method for
their results and especially for its low cost and ease of operation.
|
4 |
Influência de escâneres CAD/CAM na adaptação marginal de infraestruturas em zircônia implanto-suportadasResende, Caio César Dias 15 February 2017 (has links)
CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / FAPEMIG - Fundação de Amparo a Pesquisa do Estado de Minas Gerais / 0 objetivo desse estudo foi comparar a adaptação marginal de infraestruturas em zircônia confeccionadas pelo sistema CAD/CAM, utilizando dois escâneres e uma única fresadora, por meio do microscópio eletrônico de varredura (MEV). Materiais e métodos: Dez infraestruturas aparafusadas, implanto-suportadas, de três elementos foram divididas em dois grupos para avaliara adaptação marginal no modelo boca. Dez infraestruturas em zircônia foram fabricadas por uma única fresadora, cinco foram obtidas por meio do escaneamento com o escâner 7series Dental Wings e cinco com o escâner Ceramill map 400. A desadaptação vertical e horizontal da interface protética (mesial e distai de todos os implantes) foram analisadas e mensuradas pelo MEV, resultando em trinta medidas por grupo (n=30). As medidas foram obtidas em duas situações, a primeira quando um parafuso central está posicionado e a segunda com todos os parafusos apertados. A análise estatística foi realizada utilizando o teste estatístico U Mann-Whitney (a=.05) para desadaptações verticais. Os valores de desadaptações horizontais foram divididos em três situações: sobre extensão, zero e sub extensão.
Resultados: Diferença estatística significante foi encontrada entre os valores de desadaptação marginal quando todos os parafusos estavam apertados, porém todos esses valores estão abaixo de 16 pm. Cinco e Dezoito valores de desadaptação horizontal foram encontrados nos escâneres 7series Dental Wings e Ceramil map 400, respectivamente.
Conclusão: O uso de diferentes escâneres apresenta influencia na adaptação final de infraestruturas. / The purpose of this study was to compare the fit accuracy of CAD/CAM- fabricated zirconia frameworks using two different scanners and the same milling unit by scanning electron microscopy (SEM).
Material and methods. Ten 3-unit implant-supported, screw-retained frameworks were fabricated to fit a mastermodel. The same manufacturing milling unit fabricated all the frameworks using two scanners, five frameworks for each group: 7series Dental Wings and Ceramill map 400. The vertical and horizontal misfit at the implant-framework interface (mesial and distal of all implants) were measured by SEM resulting in 30 measurements per group (n=30) when only 1 screw was tightened and after all screws were tightened. The statistical analysis was performed using Mann-Whitney test (a=.05) by vertical misfit. Horizontal misfit values were separated in three situations: underextension, zero and overextension.
Results: Significant difference was found between the fit accuracy of the two groups when all screws were tightened, however all values is below 16 pm. Five and eighteen horizontal misfit were found in Dental Wings and Ceramill map 400, respectively.
Conclusions: The use of different scanners have influence on fit accuracy of zirconia frameworks. / Dissertação (Mestrado)
|
5 |
Estudo de porosidade por processamento de imagens aplicada a patologias do concreto / Computer vision system for identification of alkali aggregate in concrete imageRodrigo Erthal Wilson 11 August 2015 (has links)
A reação álcali-agregado - RAA é uma patologia de ação lenta que tem sido observada
em construções de concreto capaz de comprometer suas estruturas. Sabe-se que a reação
álcali-agregado é um fenômeno bastante complexo em virtude da grande variedade de rochas
na natureza que são empregadas como agregados no preparo do concreto, podendo cada
mineral utilizado afetar de forma distinta a reação ocorrida. Em função dos tipos de estrutura,
das suas condições de exposição e dos materiais empregados, a RAA não se comporta sempre
da mesma forma, em virtude disto a pesquisa constante neste tema é necessária para o meio
técnico e a sociedade. Pesquisas laboratoriais, empíricas e experimentais tem sido rotina em
muitos dos estudos da RAA dada ainda à carência de certas definições mais precisas a
respeito dos métodos de ensaio, mas também em função da necessidade do melhor
conhecimento dos materiais de uso em concretos como os agregados, cimentos, adições,
aditivos entre outros e do comportamento da estrutura. Embora técnicas de prevenção possam
reduzir significativamente a incidência da RAA, muitas estruturas foram construídas antes
que tais medidas fossem conhecidas, havendo no Brasil vários casos de estruturas afetadas,
sendo custosos os reparos dessas estruturas. Em estudos recentes sobre o tamanho das
partículas de álcali-agregado e sua distribuição foi concluído que o tamanho do agregado está
relacionado com o potencial danoso da RAA. Existem ainda indícios de que o tamanho e a
distribuição dos poros do concreto também sejam capazes de influenciar o potencial reativo
do concreto. Neste trabalho desenvolvemos um Sistema de Visão Artificial (SVA) que, com o
uso de técnicas de Processamento de Imagens, é capaz de identificar em imagens de concreto,
agregado e poros que atendam em sua forma, às especificações do usuário, possibilitando o
cálculo da porosidade e produzindo imagens segmentadas à partir das quais será possível
extrair dados relativos à geometria desses elementos. Serão feitas duas abordagens para a
obtenção das imagens, uma por Escâner Comercial, que possui vantagens relacionadas à
facilidade de aquisição do equipamento, e outra por micro tomógrafo. Uma vez obtidas
informações sobre as amostras de concreto, estas podem ser utilizadas para pesquisar a RAA,
comparar estruturas de risco com estruturas antigas de forma a melhorar a previsão de risco de
ocorrência, bem como serem aplicadas a outras no estudo de outras patologias do concreto
menos comuns no nosso país, como o efeito gelo/degelo. / The alkali-aggregate reaction - RAA is a condition of slow action that has been
observed in concrete constructions that could affect their structures. It is known that the
alkali-aggregate reaction is a very complex phenomenon because of the great variety of rocks
in nature that are used as aggregates for concrete, and each mineral used differently affects the
reaction occurred. Depending on the type of structure, its exposure conditions and the
materials used, this phenomenon does not always behaves the same way, because of this,
constant research in this area is needed for the technical means and the society. Laboratory,
empirical and experimental research has been routine in many of the RAA studies still given
the lack of certain more precise definitions concerning the testing methods, but also because
of the need for better understanding of the use of materials in concrete as aggregate, cement,
additions, additives etc. and structure behavior. Prevention techniques could significantly
reduce the incidence of RAA. Still, many structures were built before such measures were
known, several cases of affected structures were discovered in Brazil, all with large spending
on repairs of the affected structures. In recent studies on the particle size of the alkaliaggregate
and its distribution was concluded that the aggregate size is related to the damaging
potential of the RAA. There are also indications that the size and distribution of concrete
pores are also capable of influencing the reactive potential of the concrete. In the present work
we developed an Artificial Vision System ( VAS ) that uses image processing techniques to
identify aggregate and pores in hardened concrete images, enabling the calculation of porosity
and producing segmented images that can be used to investigate data about the geometry of
these elements. Were made two approaches for obtaining the images, one by Scanner
Commercial, which has related advantages will ease the acquisition of equipment, and other
micro CT scanner. Once obtained information on the concrete samples, these can be used to
search the AAR compared risk structures with old structures so as to enhance the occurrence
of risk prediction, as well as be applied to other concrete in the study of other pathologies less
common in our country, as ice effect / thaw.
|
6 |
Estudo de porosidade por processamento de imagens aplicada a patologias do concreto / Computer vision system for identification of alkali aggregate in concrete imageRodrigo Erthal Wilson 11 August 2015 (has links)
A reação álcali-agregado - RAA é uma patologia de ação lenta que tem sido observada
em construções de concreto capaz de comprometer suas estruturas. Sabe-se que a reação
álcali-agregado é um fenômeno bastante complexo em virtude da grande variedade de rochas
na natureza que são empregadas como agregados no preparo do concreto, podendo cada
mineral utilizado afetar de forma distinta a reação ocorrida. Em função dos tipos de estrutura,
das suas condições de exposição e dos materiais empregados, a RAA não se comporta sempre
da mesma forma, em virtude disto a pesquisa constante neste tema é necessária para o meio
técnico e a sociedade. Pesquisas laboratoriais, empíricas e experimentais tem sido rotina em
muitos dos estudos da RAA dada ainda à carência de certas definições mais precisas a
respeito dos métodos de ensaio, mas também em função da necessidade do melhor
conhecimento dos materiais de uso em concretos como os agregados, cimentos, adições,
aditivos entre outros e do comportamento da estrutura. Embora técnicas de prevenção possam
reduzir significativamente a incidência da RAA, muitas estruturas foram construídas antes
que tais medidas fossem conhecidas, havendo no Brasil vários casos de estruturas afetadas,
sendo custosos os reparos dessas estruturas. Em estudos recentes sobre o tamanho das
partículas de álcali-agregado e sua distribuição foi concluído que o tamanho do agregado está
relacionado com o potencial danoso da RAA. Existem ainda indícios de que o tamanho e a
distribuição dos poros do concreto também sejam capazes de influenciar o potencial reativo
do concreto. Neste trabalho desenvolvemos um Sistema de Visão Artificial (SVA) que, com o
uso de técnicas de Processamento de Imagens, é capaz de identificar em imagens de concreto,
agregado e poros que atendam em sua forma, às especificações do usuário, possibilitando o
cálculo da porosidade e produzindo imagens segmentadas à partir das quais será possível
extrair dados relativos à geometria desses elementos. Serão feitas duas abordagens para a
obtenção das imagens, uma por Escâner Comercial, que possui vantagens relacionadas à
facilidade de aquisição do equipamento, e outra por micro tomógrafo. Uma vez obtidas
informações sobre as amostras de concreto, estas podem ser utilizadas para pesquisar a RAA,
comparar estruturas de risco com estruturas antigas de forma a melhorar a previsão de risco de
ocorrência, bem como serem aplicadas a outras no estudo de outras patologias do concreto
menos comuns no nosso país, como o efeito gelo/degelo. / The alkali-aggregate reaction - RAA is a condition of slow action that has been
observed in concrete constructions that could affect their structures. It is known that the
alkali-aggregate reaction is a very complex phenomenon because of the great variety of rocks
in nature that are used as aggregates for concrete, and each mineral used differently affects the
reaction occurred. Depending on the type of structure, its exposure conditions and the
materials used, this phenomenon does not always behaves the same way, because of this,
constant research in this area is needed for the technical means and the society. Laboratory,
empirical and experimental research has been routine in many of the RAA studies still given
the lack of certain more precise definitions concerning the testing methods, but also because
of the need for better understanding of the use of materials in concrete as aggregate, cement,
additions, additives etc. and structure behavior. Prevention techniques could significantly
reduce the incidence of RAA. Still, many structures were built before such measures were
known, several cases of affected structures were discovered in Brazil, all with large spending
on repairs of the affected structures. In recent studies on the particle size of the alkaliaggregate
and its distribution was concluded that the aggregate size is related to the damaging
potential of the RAA. There are also indications that the size and distribution of concrete
pores are also capable of influencing the reactive potential of the concrete. In the present work
we developed an Artificial Vision System ( VAS ) that uses image processing techniques to
identify aggregate and pores in hardened concrete images, enabling the calculation of porosity
and producing segmented images that can be used to investigate data about the geometry of
these elements. Were made two approaches for obtaining the images, one by Scanner
Commercial, which has related advantages will ease the acquisition of equipment, and other
micro CT scanner. Once obtained information on the concrete samples, these can be used to
search the AAR compared risk structures with old structures so as to enhance the occurrence
of risk prediction, as well as be applied to other concrete in the study of other pathologies less
common in our country, as ice effect / thaw.
|
Page generated in 0.0425 seconds