• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 33
  • 3
  • Tagged with
  • 36
  • 24
  • 24
  • 14
  • 13
  • 12
  • 11
  • 10
  • 10
  • 10
  • 8
  • 8
  • 7
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Validação do instrumento de medida da resistência da musculatura espástica flexora de punho e dedos / Validation of the instrument to measure the resistance of the spastic flexor muscles of the wrist and fingers

Débora Couto de Melo Carrijo 17 January 2013 (has links)
A espasticidade é uma das alterações decorrentes do Acidente Vascular Encefálico (AVE) que causa limitação no tônus muscular podendo gerar graves comprometimentos funcionais nos membros superiores. Pela característica do tecido neurológico lesado, frequentemente ocorre a cronificação das sequelas e incapacidades e atuar na minimização desses comprometimentos é objetivo dos profissionais da saúde. No entanto, há dificuldades na escolha da intervenção, análise de sua eficácia e aprimoramento dos estudos na área da reabilitação decorrentes da limitação nas estratégias de avaliação, sendo que nessa área as escalas são utilizadas com frequência. Dessa forma, esse estudo buscou desenvolver e validar a utilização clínica de um instrumento de medida da resistência isométrica ao estiramento passivo do grupo muscular flexor do punho em adultos e idosos com espasticidade decorrente do AVE. Foi desenvolvido um instrumento portátil capaz de medir a resistência da musculatura com um torquímetro. Foram realizados testes para analisar a validade, confiabilidade, sensibilidade e praticabilidade. Os testes foram feitos com os sujeitos sentados e com o antebraço e mão fixados no aparelho em seis diferentes posições do arco do movimento do punho, sendo que a articulação permaneceu estável por 20 segundos em cada posição. Foi realizada a avaliação de 108 sujeitos. A avaliação unilateral foi realizada em 21 sujeitos sem lesão neurológica e 27 sujeitos com AVE. A avaliação bilateral por dois examinadores foi realizada em 60 sujeitos, sendo 19 sem lesão e 41 com lesão neurológica. O instrumento mostrou-se capaz de mensurar as diferenças da resistência da musculatura em cinco das seis posições sendo relevante salientar que o instrumento foi sensível para apresentar a diferença entre população normal e com lesão e posteriormente apresentando a diferença entre lado comprometido e não comprometido. Os testes inter-examinadores mostraram boa correlação, no entanto, considerou-se a distribuição da segunda avaliação mais uniforme, sugerindo que se deve padronizar o uso para que o examinador realize a sequência de avaliação do arco do movimento por, no mínimo, duas vezes. Evidenciou-se ainda que o instrumento foi sensível para graduar a intensidade da sequela utilizando-se da comparação entre o lado não comprometido e o comprometido, sempre que a sequela seja apenas do hemicorpo visto que a graduação atribuída pela Escala Modificada de Ashworth possibilitou identificar correlação com as resistências apenas na avaliação grau 3, sendo que nos demais graus, não houve evidência estatística, corroborando com os também apresentados na literatura. Sugere-se, como continuidade do estudo, correlacionar os dados obtidos da avaliação da resistência estática à dinâmica. Esse instrumento desenvolvido pode ser utilizado para avaliação dos efeitos de órteses posicionadoras de punho, contribuindo assim, para o aprimoramento das estratégias de reabilitação. / Spasticity is one of the changes resulting from stroke which causes limitation in muscle tone and may cause severe functional impairment of the upper limbs. For the feature damaged neurological tissue often occurs chronicity of disabilities and act on these commitments is minimization objective of health professionals. However, there are difficulties in the choice of intervention, analysis and improvement of its effectiveness studies in rehabilitation due to limitations in assessment strategies, and this area scales are frequently used. Thus, this study sought to develop and validate the clinical use of an instrument for measuring isometric resistance to passive stretching of the wrist flexor muscle group in adult and elderly patients with spasticity due to stroke. We developed a portable instrument capable of measuring the muscular strength of a torquemeter. Tests were conducted to examine the validity, reliability, sensitivity and practicability. Tests were performed with the subjects seated with the forearm and hand set in the apparatus in six different positions of the arc of movement of the wrist, and the joint remained stable for 20 seconds at each position. Our evaluation of 108 subjects. The evaluation was performed unilaterally in 21 subjects without neurological injury and 27 subjects with stroke. A bilateral assessment by two examiners was performed in 60 subjects, 19 with and 41 without injury neurological injury. The instrument was able to measure differences in muscle strength in five of the six positions is important to note that the instrument was sensitive to show the difference between normal population and with injury and presents the difference between the affected and non-affected. The tests showed good inter-rater correlation, however, was considered a distribution more uniform the second evaluation, suggesting that it should use to standardize the examiner performs the evaluation sequence of the arc of movement by at least twice . It is further demonstrated that the instrument was sensitive to grade the intensity of the sequel using comparing the committed and uncommitted side where the sequel of the hemisphere is only seen that the graduation given by the Modified Ashworth Scale possible to identify a correlation with resistance only in the evaluation grade 3, and in the remaining degrees, there was no statistical evidence, corroborating also presented in the literature. It is suggested, as a continuation of the study, correlate data obtained from the evaluation of the resistance to static dynamic. This tool developed can be used to assess the effects of splint of wrist, thus contributing to the improvement of rehabilitation strategies.
12

Correlação entre o sinal mecanomiográfico e a escala modificada de Ashworth durante avaliação clínica da espasticidade / Correlation between the MMG signal and the modified Ashworth scale for clinical assessment of spasticity

Santos, Elgison da Luz dos 29 February 2016 (has links)
A espasticidade é uma desordem comum em pessoas que apresentam lesão no neurônio motor superior. O acometimento pode ocorrer em diferentes níveis. A Escala Modificada de Ashworth (EMA) é o instrumento de avaliação mais utilizado para medir os níveis de acometimento, entretanto apresenta subjetividade. Já a mecanomiografia (MMG) trata-se de uma técnica objetiva, que quantifica as vibrações musculares durante os eventos de contração e alongamento e, por isso, pode dimensionar com precisão o nível de espasticidade. Diante disso, objetivou-se investigar a correlação entre os níveis de espasticidade determinados pela EMA com os sinais mecanomiográficos em músculos espásticos e não espásticos. Avaliaram-se 34 membros de 22 voluntários, de ambos os sexos, com idade média de 39,91±13,77 anos. O protocolo experimental consistiu na realização de avaliação pela EMA dos grupos musculares flexores e extensores de joelho e/ou cotovelo, onde um grupo era o agonista e o outro antagonista. Simultaneamente, captavam-se os sinais de MMG. Utilizou-se um equipamento de MMG customizado para registrar e gravar os sinais, configurados em um programa da plataforma LabView®. No programa computacional MatLab®, processaram-se os sinais da MMG no domínio temporal (mediana da energia) e espectral (mediana da frequência) dos eixos de movimento X (transversal), Y (longitudinal) e Z (perpendicular). Para delimitação da banda passante, empregou-se um filtro Butterworth de 3a ordem atuando na faixa de 5 a 50 Hz. Aplicaram-se testes estatísticos como coeficiente de correlação de Spearman, teste de Kruskall-Wallis e teste de correlação linear. Como resultados, no domínio temporal, o teste de Kruskal- Wallis mostrou diferenças na mediana da energia (MMG ME) entre cada grupo de EMA. O teste de correlação linear mostrou alta correlação entre a EMA e a MMGME, tanto no grupo muscular agonista quanto no antagonista. Assim, no domínio do tempo, a maior correlação linear ocorreu entre a EMA e a MMGME do eixo Z do grupo muscular agonista (R2 = 0,9557) e a menor correlação no eixo X, do antagonista (R 2 = 0,8862). O teste de correlação de Spearman também confirmou alta correlação em todos os eixos, nesta análise. O processamento no domínio espectral mostrou que houve aumento na mediana da frequência (MMGMF) nos maiores graus de EMA. Porém, os coeficientes de correlação linear determinados foram moderados e baixos. O maior coeficiente de correlação linear entre a EMA e a MMGMF ocorreu no eixo Z, do grupo muscular agonista (R2 = 0,4883) e o menor valor no eixo Y, do grupo antagonista (R 2 = 0,1657). No teste de Spearman, a maior correlação ocorreu entre o eixo Y do grupo agonista (0,6951; p < 0,001) e o menor valor no eixo X do grupo antagonista (0,3592; p < 0,001). Por meio dos dados obtidos, concluiu-se que entre a MMGME e a EMA houve correlação significativamente elevada em ambos os grupos musculares. Entre a MMGMF e a EMA também houve correlação significativa, porém moderada no grupo agonista, e fraca no grupo antagonista. Desta forma, dentre os descritores estudados, a MMGME mostrou ser a mais adequada para correlacionar-se com o grau de espasticidade definido pela EMA. / Spasticity is a common disorder in people who have upper motor neuron injury. The involvement may occur at different levels. The Modified Ashworth Scale (MAS) is the most used method to measure involvement levels. But it corresponds to a subjective evaluation. Mechanomyography (MMG) is an objective technique that quantifies the muscle vibration during the contraction and stretching events. So, it may assess the level of spasticity accurately. This study aimed to investigate the correlation between spasticity levels determined by MAS with MMG signal in spastic and not spastic muscles. In the experimental protocol, we evaluated 34 members of 22 volunteers, of both genders, with a mean age of 39.91 ± 13.77 years. We evaluated the levels of spasticity by MAS in flexor and extensor muscle groups of the knee and/or elbow, where one muscle group was the agonist and one antagonist. Simultaneously the assessment by the MAS, caught up the MMG signals. We used a custom MMG equipment to register and record the signals, configured in LabView platform. Using the MatLab computer program, it was processed the MMG signals in the time domain (median energy) and spectral domain (median frequency) for the three motion axes: X (transversal), Y (longitudinal) and Z (perpendicular). For bandwidth delimitation, we used a 3rd order Butterworth filter, acting in the range of 5-50 Hz. Statistical tests as Spearman's correlation coefficient, Kruskal-Wallis test and linear correlation test were applied. As results in the time domain, the Kruskal-Wallis test showed differences in median energy (MMGME) between MAS groups. The linear correlation test showed high linear correlation between MAS and MMGME for the agonist muscle as well as for the antagonist group. The largest linear correlation occurred between the MAS and MMG ME for the Z axis of the agonist muscle group (R2 = 0.9557) and the lowest correlation occurred in the X axis, for the antagonist muscle group (R2 = 0.8862). The Spearman correlation test also confirmed high correlation for all axes in the time domain analysis. In the spectral domain, the analysis showed an increase in the median frequency (MMGMF) in MAS’ greater levels. The highest correlation coefficient between MAS and MMGMF signal occurred in the Z axis for the agonist muscle group (R2 = 0.4883), and the lowest value occurred on the Y axis for the antagonist group (R2 = 0.1657). By means of the Spearman correlation test, the highest correlation occurred between the Y axis of the agonist group (0.6951; p <0.001) and the lowest value on the X axis of the antagonist group (0.3592; p <0.001). We conclude that there was a significantly high correlation between the MMGME and MAS in both muscle groups. Also between MMG and MAS occurred a significant correlation, however moderate for the agonist group, and low for the antagonist group. So, the MMGME proved to be more an appropriate descriptor to correlate with the degree of spasticity defined by the MAS.
13

Correlação entre o sinal mecanomiográfico e a escala modificada de Ashworth durante avaliação clínica da espasticidade / Correlation between the MMG signal and the modified Ashworth scale for clinical assessment of spasticity

Santos, Elgison da Luz dos 29 February 2016 (has links)
A espasticidade é uma desordem comum em pessoas que apresentam lesão no neurônio motor superior. O acometimento pode ocorrer em diferentes níveis. A Escala Modificada de Ashworth (EMA) é o instrumento de avaliação mais utilizado para medir os níveis de acometimento, entretanto apresenta subjetividade. Já a mecanomiografia (MMG) trata-se de uma técnica objetiva, que quantifica as vibrações musculares durante os eventos de contração e alongamento e, por isso, pode dimensionar com precisão o nível de espasticidade. Diante disso, objetivou-se investigar a correlação entre os níveis de espasticidade determinados pela EMA com os sinais mecanomiográficos em músculos espásticos e não espásticos. Avaliaram-se 34 membros de 22 voluntários, de ambos os sexos, com idade média de 39,91±13,77 anos. O protocolo experimental consistiu na realização de avaliação pela EMA dos grupos musculares flexores e extensores de joelho e/ou cotovelo, onde um grupo era o agonista e o outro antagonista. Simultaneamente, captavam-se os sinais de MMG. Utilizou-se um equipamento de MMG customizado para registrar e gravar os sinais, configurados em um programa da plataforma LabView®. No programa computacional MatLab®, processaram-se os sinais da MMG no domínio temporal (mediana da energia) e espectral (mediana da frequência) dos eixos de movimento X (transversal), Y (longitudinal) e Z (perpendicular). Para delimitação da banda passante, empregou-se um filtro Butterworth de 3a ordem atuando na faixa de 5 a 50 Hz. Aplicaram-se testes estatísticos como coeficiente de correlação de Spearman, teste de Kruskall-Wallis e teste de correlação linear. Como resultados, no domínio temporal, o teste de Kruskal- Wallis mostrou diferenças na mediana da energia (MMG ME) entre cada grupo de EMA. O teste de correlação linear mostrou alta correlação entre a EMA e a MMGME, tanto no grupo muscular agonista quanto no antagonista. Assim, no domínio do tempo, a maior correlação linear ocorreu entre a EMA e a MMGME do eixo Z do grupo muscular agonista (R2 = 0,9557) e a menor correlação no eixo X, do antagonista (R 2 = 0,8862). O teste de correlação de Spearman também confirmou alta correlação em todos os eixos, nesta análise. O processamento no domínio espectral mostrou que houve aumento na mediana da frequência (MMGMF) nos maiores graus de EMA. Porém, os coeficientes de correlação linear determinados foram moderados e baixos. O maior coeficiente de correlação linear entre a EMA e a MMGMF ocorreu no eixo Z, do grupo muscular agonista (R2 = 0,4883) e o menor valor no eixo Y, do grupo antagonista (R 2 = 0,1657). No teste de Spearman, a maior correlação ocorreu entre o eixo Y do grupo agonista (0,6951; p < 0,001) e o menor valor no eixo X do grupo antagonista (0,3592; p < 0,001). Por meio dos dados obtidos, concluiu-se que entre a MMGME e a EMA houve correlação significativamente elevada em ambos os grupos musculares. Entre a MMGMF e a EMA também houve correlação significativa, porém moderada no grupo agonista, e fraca no grupo antagonista. Desta forma, dentre os descritores estudados, a MMGME mostrou ser a mais adequada para correlacionar-se com o grau de espasticidade definido pela EMA. / Spasticity is a common disorder in people who have upper motor neuron injury. The involvement may occur at different levels. The Modified Ashworth Scale (MAS) is the most used method to measure involvement levels. But it corresponds to a subjective evaluation. Mechanomyography (MMG) is an objective technique that quantifies the muscle vibration during the contraction and stretching events. So, it may assess the level of spasticity accurately. This study aimed to investigate the correlation between spasticity levels determined by MAS with MMG signal in spastic and not spastic muscles. In the experimental protocol, we evaluated 34 members of 22 volunteers, of both genders, with a mean age of 39.91 ± 13.77 years. We evaluated the levels of spasticity by MAS in flexor and extensor muscle groups of the knee and/or elbow, where one muscle group was the agonist and one antagonist. Simultaneously the assessment by the MAS, caught up the MMG signals. We used a custom MMG equipment to register and record the signals, configured in LabView platform. Using the MatLab computer program, it was processed the MMG signals in the time domain (median energy) and spectral domain (median frequency) for the three motion axes: X (transversal), Y (longitudinal) and Z (perpendicular). For bandwidth delimitation, we used a 3rd order Butterworth filter, acting in the range of 5-50 Hz. Statistical tests as Spearman's correlation coefficient, Kruskal-Wallis test and linear correlation test were applied. As results in the time domain, the Kruskal-Wallis test showed differences in median energy (MMGME) between MAS groups. The linear correlation test showed high linear correlation between MAS and MMGME for the agonist muscle as well as for the antagonist group. The largest linear correlation occurred between the MAS and MMG ME for the Z axis of the agonist muscle group (R2 = 0.9557) and the lowest correlation occurred in the X axis, for the antagonist muscle group (R2 = 0.8862). The Spearman correlation test also confirmed high correlation for all axes in the time domain analysis. In the spectral domain, the analysis showed an increase in the median frequency (MMGMF) in MAS’ greater levels. The highest correlation coefficient between MAS and MMGMF signal occurred in the Z axis for the agonist muscle group (R2 = 0.4883), and the lowest value occurred on the Y axis for the antagonist group (R2 = 0.1657). By means of the Spearman correlation test, the highest correlation occurred between the Y axis of the agonist group (0.6951; p <0.001) and the lowest value on the X axis of the antagonist group (0.3592; p <0.001). We conclude that there was a significantly high correlation between the MMGME and MAS in both muscle groups. Also between MMG and MAS occurred a significant correlation, however moderate for the agonist group, and low for the antagonist group. So, the MMGME proved to be more an appropriate descriptor to correlate with the degree of spasticity defined by the MAS.
14

A EQUOTERAPIA NA REABILITAÇÃO DE CRIANÇAS PORTADORAS DE PARALISIA CEREBRAL / The hippotherapy in rehabilitation of children affected by Cerebral Paralysis

Araujo, Ana Eugenia Ribeiro de Araujo e 20 August 2007 (has links)
Made available in DSpace on 2016-08-19T18:15:55Z (GMT). No. of bitstreams: 1 ANA EUGENIA RIBEIRO DE ARAUJO E ARAUJO.pdf: 1138893 bytes, checksum: 86e944da346d6667f00a4a6ed7a7fdec (MD5) Previous issue date: 2007-08-20 / Cerebral Paralysis (CP) comprehends a series of non progressive syndromes of motor and posture disturbances, resulting from irreversible damage to the developing central nervous system. The hippotherapy is a therapeutical and educational method that uses a horse in an interdisciplinary approach attempting to enhance the posture stability in children affected by Cerebral Paralysis (CP). This work aim is to evaluate the benefits PC diagnosed children can attain after one year participation in an hippotherapy program. 27 spastic diplegia PC diagnosed children were studied (15 boys and 17 girls) ranging from 2 to 12 years of age. As to evaluate the following body parts: head and neck, shoulders and scapulae, trunk, vertebral column and pelvis, before and after hippotherapy treatment, a scale, standardized by the interdisciplinary medical team of the hippotherapy center, was used. The program was conducted once a week, in sessions of 45 minutes each. There were verified posture benefits statistically significant (p<0.05) in all body parts, especially in those presenting the worst asymmetry conditions before the treatment, such as the trunk and pelvis. One can conclude stating that the hippotherapy treatment positively influenced the posture adjustment as well as the children s static and dynamic equilibrium, thus improving their motor abilities and contributing to the walking prediction. / A Paralisia Cerebral (PC) compreende uma série de síndromes não progressivas de distúrbios motores e de postura, resultantes de um dano irreversível no sistema nervoso central em desenvolvimento. A Equoterapia é um método terapêutico e educacional que utiliza o cavalo dentro de uma abordagem interdisciplinar, visando melhorar a estabilidade postural em crianças com Paralisia Cerebral (PC). Objetivou-se avaliar os benefícios posturais em crianças com paralisia cerebral (PC) após a participação num programa de equoterapia durante um ano. Estudou-se vinte e sete crianças (quinze meninos, doze meninas) diagnosticadas com Paralisia Cerebral espástica diplegica, com idade entre 2 a 12 anos. Utilizou-se uma escala padronizada pela equipe interdisciplinar do centro de equoterapia para avaliar a postura dos seguintes segmentos corporais: cabeça e pescoço, ombros e escápula, tronco, coluna vertebral e pélvis, antes e depois da equoterapia. O programa aconteceu uma vez por semana, numa sessão de 45 minutos. Verificou-se benefícios posturais estatisticamente significantes (p<0,05) em todos os segmentos corporais, especialmente naqueles que apresentaram as piores condições de assimetria antes do tratamento, como o tronco e pélvis. Concluiu-se que a equoterapia influenciou positivamente no ajuste postural assim como no equilíbrio estático e dinâmico da criança, aprimorando desta forma, suas habilidades motoras e contribuindo para o prognóstico de marcha.
15

Ensaio clínico randomizado duplo-cego comparando duas apresentações de toxina botulínica tipo A no tratamento de espasticidade disfuncional focal

Guarany, Fábio Coelho January 2013 (has links)
Introdução: A toxina botulínica tipo A é uma das principais modalidades de tratamento para pacientes com espasticidade. Uma nova preparações de toxina botulínica sorotipo tipo A, Prosigne®, foi lançada sugerindo ter a mesma eficácia que Botox®. No entanto, não há ensaios clínicos randomizados comparando essas formulações no tratamento da espasticidade. Objetivos: O objetivo deste estudo foi comparar a eficácia ea segurança do Prosigne® com Botox® no tratamento da espasticidade. Métodos: Foi realizado um estudo duplo-cego, randomizado e cruzado com 57 pacientes com espasticidade clinicamente significativas. Os pacientes foram avaliados no início do estudo, 4 e 12 semanas após a injeção de Prosigne® ou Botox®. Resultados: Os principais resultados foram avaliados pelas mudanças na Escala de Ashworth Modificada (EAM), Medida de Independência Funcional MIF) e Pediatric Evaluation of Disability Inventory (PEDI) e os efeitos adversos relacionados ao uso da toxina botulínica. Ambas as toxinas foram significativamente eficazes em diminuir o grau de espasticidade, em adultos e crianças. Não houveram diferenças significativas entre os tratamentos Prosigne® e Botox® em relação aos escores MAS, e FIM PEDI. Da mesma forma, a incidência de efeitos adversos foi similar entre os dois grupos. Conclusão: Nossos resultados sugerem que Prosigne® e Botox® são comparáveis em relação a sua eficácia e segurança no tratamento de três meses da espasticidade. / Background: Botulinum toxin type A is one of the main treatment choices for patients with spasticity. Prosigne® a new released botulinum toxin serotype A may have the same effectiveness as Botox®. However, there are no randomized clinical trials comparing these formulations in spasticity treatment. Objective: The aim of our study was to compare the efficacy and safety of Prosigne® with Botox® in the treatment of spasticity. Methods: We performed a double-blind, randomized, crossover study consisting of 57 patients with clinically meaningful spasticity. The patients were assessed at baseline, 4 and 12 weeks after Prosigne® or Botox® administration. Results: The main outcomes were changes in the patients’ Modified Ashworth Scale (MAS), Functional Independence Measure (FIM) and Pediatric Evaluation of Disability Inventory (PEDI) scores and adverse effects related to the botulinum toxin. Both of the toxins were significantly effective in relieving the level of spasticity in adults and children. There were no significant differences found between the Prosigne® and Botox® treatments regarding their MAS, FIM and PEDI scores. Likewise, the incidence of adverse effects was similar between the two groups. Conclusion: Our results suggest that Prosigne® and Botox® are both efficient and comparable with respect to their efficacy and safety for the three month treatment of spasticity.
16

Ensaio clínico randomizado duplo-cego comparando duas apresentações de toxina botulínica tipo A no tratamento de espasticidade disfuncional focal

Guarany, Fábio Coelho January 2013 (has links)
Introdução: A toxina botulínica tipo A é uma das principais modalidades de tratamento para pacientes com espasticidade. Uma nova preparações de toxina botulínica sorotipo tipo A, Prosigne®, foi lançada sugerindo ter a mesma eficácia que Botox®. No entanto, não há ensaios clínicos randomizados comparando essas formulações no tratamento da espasticidade. Objetivos: O objetivo deste estudo foi comparar a eficácia ea segurança do Prosigne® com Botox® no tratamento da espasticidade. Métodos: Foi realizado um estudo duplo-cego, randomizado e cruzado com 57 pacientes com espasticidade clinicamente significativas. Os pacientes foram avaliados no início do estudo, 4 e 12 semanas após a injeção de Prosigne® ou Botox®. Resultados: Os principais resultados foram avaliados pelas mudanças na Escala de Ashworth Modificada (EAM), Medida de Independência Funcional MIF) e Pediatric Evaluation of Disability Inventory (PEDI) e os efeitos adversos relacionados ao uso da toxina botulínica. Ambas as toxinas foram significativamente eficazes em diminuir o grau de espasticidade, em adultos e crianças. Não houveram diferenças significativas entre os tratamentos Prosigne® e Botox® em relação aos escores MAS, e FIM PEDI. Da mesma forma, a incidência de efeitos adversos foi similar entre os dois grupos. Conclusão: Nossos resultados sugerem que Prosigne® e Botox® são comparáveis em relação a sua eficácia e segurança no tratamento de três meses da espasticidade. / Background: Botulinum toxin type A is one of the main treatment choices for patients with spasticity. Prosigne® a new released botulinum toxin serotype A may have the same effectiveness as Botox®. However, there are no randomized clinical trials comparing these formulations in spasticity treatment. Objective: The aim of our study was to compare the efficacy and safety of Prosigne® with Botox® in the treatment of spasticity. Methods: We performed a double-blind, randomized, crossover study consisting of 57 patients with clinically meaningful spasticity. The patients were assessed at baseline, 4 and 12 weeks after Prosigne® or Botox® administration. Results: The main outcomes were changes in the patients’ Modified Ashworth Scale (MAS), Functional Independence Measure (FIM) and Pediatric Evaluation of Disability Inventory (PEDI) scores and adverse effects related to the botulinum toxin. Both of the toxins were significantly effective in relieving the level of spasticity in adults and children. There were no significant differences found between the Prosigne® and Botox® treatments regarding their MAS, FIM and PEDI scores. Likewise, the incidence of adverse effects was similar between the two groups. Conclusion: Our results suggest that Prosigne® and Botox® are both efficient and comparable with respect to their efficacy and safety for the three month treatment of spasticity.
17

Efeitos do tratamento da espasticidade com toxina botulínica do tipo A na função motora grossa de lactentes com Paralisia Cerebral forma Hemiplégica

Zonta, Marise Bueno 08 February 2010 (has links)
No description available.
18

Quantidade e qualidade do uso da extremidade superior paretica apos acidente cerebrovascular / Amount and quality of use of paretic upper extremity after stroke

Paz, Leonardo Petrus da Silva 31 August 2007 (has links)
Orientador: Antonio Guilherme Borges Neto / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-10T01:01:21Z (GMT). No. of bitstreams: 1 Paz_LeonardoPetrusdaSilva_M.pdf: 2376639 bytes, checksum: aa178fd121e97b80788530508ff7141d (MD5) Previous issue date: 2007 / Resumo: OBJETIVO: Investigar as relações entre escalas direcionadas à função do membro superior, e destas com comprometimentos sensório-motores e Ipúsculo-esqueléticos após acidente vascular cerebral (A VC). METODOLOGIA: Foram estudados 34 pacientes hemiparéticos de ambos os sexos com idade de 50,54 (f:13,53) anos e diagnóstico clínico de A VC utilizando-se: a) nível de atividade pelo Inventário de Atividade Matara (MAL) e pelo teste do Nível de Atividade da Extremidade Superior (AAUT); b) nível de recuperação sensóriomotor pelos itens da Extremidade Superior da Escala de Desempenho Físico (UE-FMA); c) dor ao movimento passivo e restrição da amplitude de movimento pelos itens da UE-FMA; d) tônus pela Escala Tônus de Ashworth (AS); e) força de preensão estática pelo dinamômetro hidráulico manual; e, f) o nível funcional com o Teste da Ação da Extremidade Superior para Pesquisa (ARA ou ARAT). AAUT e MAL foram aplicadas nas condições espontânea e forçada. Os dados foram tabelados e analisados utilizando-se estatística descritiva e correlações. RESULTADOS: -Foram encontradas altas correlações entre as escalas ARA, UE-FMA, AAUT e MAL (r2:0,70, p:S0,05). A ARA se correlacionou com UE-FMA item-a-item. A força de preensão foi o único comprometimento altamente correlacionado às escalas funcionais, não havendo correlação entre a força de preensão e a hipertonia muscular de grupamentos flexores ou extensores de punho e dedos. Foram observadas diferenças significativas entre as condições espontânea e forçada. CONCLUSÃO: A força de preensão está relacionada à função da extremidade superior, mas não há hipertonia muscular. A ARA pode ser usada para avaliação dos comprometimentos motores após A VC. O modelo para estudo do desuso aprendido e as escalas ARA, AAUT e UE-FMA são instrumentos válidos para avaliação de pacientes hemiparéticos e indicam o espectro de acometimento após A VC / Abstract: Objective: To verify the relationship between different functional scales of the upper extremity and the sensorio-motor and musculoskeletal impairments after stroke. Methods: 34 hemiparetic stroke survivors with mean age of 50,54 years (±13,53) were evaluated with the tests: a) Actual Amount of Use Test (AAUT), b) Motor Log Activity (MAL), c) Arm Research Action Test (ARA), d) the Upper Extremity itens of Fugl-Meyer Assessment (UE-FMA), e) isometric grip strength with the hydraulic dynamometer, and f) Ashworth scale. The MAL and AAUT scales was evaluate in forced and spontaneous conditions. Results: High correlations between the functional scales were found, as well as the ARA and UE-FMA items (r=0,70, com p=0,05). The ARA and UE-FMA were correlated item for item. The grip strength was the impairment most directly associated with the functional scales, but not with the spasticity of flexor or extensor muscles of hand and wrist. The median of the differences between AAUT differ significantly in both conditions, as well as the MAL. Conclusion: The grip strength was not related with the spasticity and the impairment most related with the upper extremity scales. The ARA test could be used to evaluate the motor impairments after stroke. The paradigm for investigation of the learning non-use and the scales ARA, MAL, AAUT and UE-FMA are valid tools to assess the upper extremity after stroke and indicate the spectrum of impairment after stroke / Mestrado / Ciencias Biomedicas / Mestre em Ciências Médicas
19

Ensaio clínico randomizado duplo-cego comparando duas apresentações de toxina botulínica tipo A no tratamento de espasticidade disfuncional focal

Guarany, Fábio Coelho January 2013 (has links)
Introdução: A toxina botulínica tipo A é uma das principais modalidades de tratamento para pacientes com espasticidade. Uma nova preparações de toxina botulínica sorotipo tipo A, Prosigne®, foi lançada sugerindo ter a mesma eficácia que Botox®. No entanto, não há ensaios clínicos randomizados comparando essas formulações no tratamento da espasticidade. Objetivos: O objetivo deste estudo foi comparar a eficácia ea segurança do Prosigne® com Botox® no tratamento da espasticidade. Métodos: Foi realizado um estudo duplo-cego, randomizado e cruzado com 57 pacientes com espasticidade clinicamente significativas. Os pacientes foram avaliados no início do estudo, 4 e 12 semanas após a injeção de Prosigne® ou Botox®. Resultados: Os principais resultados foram avaliados pelas mudanças na Escala de Ashworth Modificada (EAM), Medida de Independência Funcional MIF) e Pediatric Evaluation of Disability Inventory (PEDI) e os efeitos adversos relacionados ao uso da toxina botulínica. Ambas as toxinas foram significativamente eficazes em diminuir o grau de espasticidade, em adultos e crianças. Não houveram diferenças significativas entre os tratamentos Prosigne® e Botox® em relação aos escores MAS, e FIM PEDI. Da mesma forma, a incidência de efeitos adversos foi similar entre os dois grupos. Conclusão: Nossos resultados sugerem que Prosigne® e Botox® são comparáveis em relação a sua eficácia e segurança no tratamento de três meses da espasticidade. / Background: Botulinum toxin type A is one of the main treatment choices for patients with spasticity. Prosigne® a new released botulinum toxin serotype A may have the same effectiveness as Botox®. However, there are no randomized clinical trials comparing these formulations in spasticity treatment. Objective: The aim of our study was to compare the efficacy and safety of Prosigne® with Botox® in the treatment of spasticity. Methods: We performed a double-blind, randomized, crossover study consisting of 57 patients with clinically meaningful spasticity. The patients were assessed at baseline, 4 and 12 weeks after Prosigne® or Botox® administration. Results: The main outcomes were changes in the patients’ Modified Ashworth Scale (MAS), Functional Independence Measure (FIM) and Pediatric Evaluation of Disability Inventory (PEDI) scores and adverse effects related to the botulinum toxin. Both of the toxins were significantly effective in relieving the level of spasticity in adults and children. There were no significant differences found between the Prosigne® and Botox® treatments regarding their MAS, FIM and PEDI scores. Likewise, the incidence of adverse effects was similar between the two groups. Conclusion: Our results suggest that Prosigne® and Botox® are both efficient and comparable with respect to their efficacy and safety for the three month treatment of spasticity.
20

Análise clínica e funcional da espasticidade antes e após a estimulação elétrica neuromuscular e marcha em esteira com EENM em lesados medulares / Clinical and functional analysis of spasticity before and after neuromuscular electrical stimulation and treadmill gait with NMES in spinal cord injury

Tancredo, Janaina Roland, 1980- 17 January 2012 (has links)
Orientador: Alberto Cliquet Junior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-19T19:00:11Z (GMT). No. of bitstreams: 1 Tancredo_JanainaRoland_M.pdf: 2653289 bytes, checksum: 0b7d643e5438e5de2faf4c696947403b (MD5) Previous issue date: 2012 / Resumo: A lesão medular tem como uma de suas conseqüências a espasticidade, que está geralmente presente em lesões acima do último nível torácico (T12) e pode ser avaliada através de indicadores quantitativos e qualitativos. Na pesquisa, foram avaliados dois grupos, o da Estimulação Elétrica Neuromuscular (EENM), com dezesseis pacientes e o grupo da Marcha em Esteira com EENM com oito pacientes; todos com diagnóstico de paraplegia e tetraplegia com algum grau de espasticidade. Foram utilizadas para esta avaliação as escalas: modificada de Ashworth, a de espasmos musculares, a subjetiva da espasticidade e o teste pendular. Para aplicação do teste pendular foi utilizado o Dispositivo de Teste Pendular (DTP) - (equipamento que foi elaborado e construído especificamente para avaliar a espasticidade, que possui um acelerômetro de transdutores de cristais de quartzo e um eletrogoniômetro de fibra óptica flexível que medem as tensões e os deslocamentos angulares, respectivamente) do Laboratório de Biomecânica e Reabilitação do Aparelho Locomotor. Os pacientes do grupo da EENM realizaram EENM nos músculos quadríceps e nervo fibular, sendo que os testes foram aplicados antes e logo após o procedimento. O mesmo foi realizado para o grupo da Marcha em Esteira com EENM. Os dados mostraram uma diminuição da espasticidade nos dois grupos, representado no grupo da EENM por variações nos parâmetros F1Ang, F1 Amp, E1 Amp, Plat Amp e ERI e no parâmetro E1 Ang no grupo da marcha. O grupo da EENM onde foi subdividido (pacientes com e sem medicação) notamos uma diferença significativa no subgrupo sem medicação na maioria dos parâmetros avaliados. Já o subgrupo com medicação apenas os parâmetros On Ang e RI foram significativos. Além disso, os dados da escala subjetiva e da escala modificada de Ashworth, após a estimulação elétrica neuromuscular também apresentaram uma redução nos valores da espasticidade, sendo que no grupo da marcha em esteira apenas a escala subjetiva foi significativa / Abstract: Spinal cord injury has as one of its consequences the spasticity, which is usually present in lesions above the last thoracic level (T12) and it can be assessed through quantitative and qualitative indicators. In the study it was evaluated two groups: Neuromuscular Electrical Stimulation (NMES) group with sixteen patients and the group of eight patients that performed treadmill gait with partial body weigth support and NMES, all of them were diagnosed with paraplegia or tetraplegia with some degree of spasticity. The following scales were used for assessment: Modified Ashworth Scale, Muscle Spasms Scale, Subjective Scale of Spasticity and the pendulum test. For application of the pendulum test it was used Pendular Test Device (PTD) was used, this equipment was designed and built specifically to evaluate spasticity, which has an accelerometer of quartz crystals transducer and a flexible fiber optic electrogoniometer to measure the acceleration and angular displacement, respectively. The patients in the NMES group performed NMES in the quadriceps muscle and fibular nerve, and the tests were applied before and after the procedure. The same was done for the treadmill gait with NMES group. The data showed a decrease in spasticity in both groups, represented in the NMES group by changes in the F1Ang, F1Amp, E1Amp, Plat Amp and ERI parameters of the PTD and the gait group also presented a change in the E1Ang. In the group NMES, which was divided (patients with and without drugs), it was noticed a significant difference in the subgroup without medication in most parameters. However, in the subgroup with medication only the OnAng and RI parameters were significant. In addition, data from the Subjective Scale of Spasticity and the Modified Ashworth Scale also showed a reduction in the values in the spasticity, and in the group of treadmill gait just a Subjective Scale of Spasticity was significant / Mestrado / Fisiopatologia Cirúrgica / Mestre em Ciências

Page generated in 0.0623 seconds