• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 127
  • Tagged with
  • 128
  • 128
  • 128
  • 38
  • 37
  • 36
  • 35
  • 26
  • 23
  • 23
  • 21
  • 20
  • 20
  • 19
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Desenvolvimento de método de determinação de cálcio, magnésio e zinco em amostras de óleo lubrificante por espectrometria de absorção atômica com chama

Zmozinski, Ariane Vanessa January 2010 (has links)
Neste trabalho foi desenvolvido um método para a determinação de Ca, Mg e Zn em óleos lubrificantes e quantificação por Espectrometria de Absorção Atômica com Chama (F AAS). As amostras foram diluídas com uma pequena quantidade de querosene de aviação (QAV), propanol e água formando uma solução de três componentes. Para a calibração, foram utilizados padrões inorgânicos aquosos. Para a avaliação da exatidão do método desenvolvido foi utilizado a norma ABNT NBR 14066, que consiste na diluição das amostras com QAV e quantificação por F AAS. Dois outros métodos para avaliar a exatidão foram empregados: digestão ácida e análise de material de referência certificado NIST (SRM 1084a). O método proposto apresentou as seguintes vantagens quando comparado com o método de referência: significativa redução do uso de QAV, maior estabilidade dos analitos no meio, utilização de padrões inorgânicos aquosos na calibração. Os valores dos limites de detecção para o Ca, Mg e Zn foram 1,3 μg g-1, 0,052 μg g-1 e 0,41 μg g-1 respectivamente. O método desenvolvido foi aplicado para amostras reais e os resultados foram concordantes com os obtidos pelos métodos de referência. / Lubricating oils are used to decrease wear and friction of movable parts. The presence of metals such as Ca, Mg and Zn show the addition of specific additives that improve the performance of these lubricants. In this work, a method for determination of Ca, Mg and Zn in lubricating oil by flame atomic absorption spectrometry (F AAS) was developed. The samples were diluted with a small quantity of aviation kerosene (AVK), n-propanol and water to form a three component solution before its introduction in the F AAS. Aqueous inorganic standards diluted in the same way have been used for calibration. To assess the accuracy of the new method, the comparison with the ABNT NBR 14066 standard method, which consist in diluting the sample with AVK and quantification by F AAS, was employed. Two other methods to evaluate the accuracy have also been used: the acid digestion method and the certified reference material NIST (SRM 1084a). The proposed method provides the following advantages when compared with the standard method: significant reduction of the use of AVK, higher stability of the analytes in the medium and application of aqueous organic standards for calibration. The limits of detection for Ca, Mg and Zn were 1.3 μg g-1, 0.052 μg g-1 and 0.41 μg g-1 respectively. The proposed method was applied to real samples and the results were consistent with those obtained by reference methods.
22

Uso de modificadores químicos permanentes na determinação de cádmio em suspensão de carvão por GF AAS convencional e de alta resolução

Bianchin, Liane January 2005 (has links)
Irídio e rutênio isoladamente e em combinação com tungstênio, termicamente depositados na plataforma de um tubo de grafite com aquecimento transversal, foram investigados quanto a sua aplicabilidade como modificadores permanentes para a determinação de cádmio em suspensões de carvão por espectrometria de absorção atômica com forno de grafite. O modificador químico de Pd-Mg adicionado em solução na forma de nitratos também foi investigado, para comparação. Este apresentou a melhor performance para solução aquosa, enquanto a mistura de W-Ir e W-Ru como modificadores permanentes apresentou o menor poder de estabilização. Todos os modificadores investigados perdem parte do seu poder de estabilização quando aplicados a suspensões de carvão. O modificador químico Pd-Mg e os modificadores permanentes Ir e Ru bem como a mistura de 300 μg de W e 200 μg de Ir estabilizam cádmio a uma temperatura de pirólise de 600 ºC, enquanto que as demais combinações investigadas permitem temperaturas de pirólise máximas entre 500 e 550 ºC. Investigações a partir da fase líquida das suspensões demonstram que existe a possibilidade de que a alta concentração de ácido empregada no preparo das suspensões e/ou compostos que são extraídos do carvão para a fase líquida podem ser responsáveis pela redução no poder de estabilização dos modificadores. A temperatura máxima de pirólise de 600 ºC não foi suficiente para reduzir a absorção de fundo provocada por concomitantes de algumas das amostras testadas, enquanto que temperaturas de pirólise mais elevadas levam à perda de analito. Para o desenvolvimento deste estudo, foram utilizados os materiais de referência BCR No 180 Gas Coal, SARM 18 Coal Witbank, SARM 19 Coal O.F.S., SARM 20 Coal Sasolburg, NIST SRM 1635, NIST SRM 1630a e SRM 1632b. Foi investigado também um carvão brasileiro da mina de Candiota no Rio Grande do Sul. Foram determinadas as figuras de mérito e os valores obtidos para o limite de detecção e a massa característica estão entre 1,0 e 1,3 ng g-1 e 1,9 e 2,2 pg, respectivamente. Estudos por espectrometria de absorção atômica de alta resolução com fonte contínua foram realizados com o intuito de elucidar as possíveis interferências provenientes de diferentes matrizes de carvão na forma de suspensão. Estes estudos revelaram que o fundo contínuo apresenta uma absorção maior do que a capacidade de correção exibida pelo corretor de deutério e que o mesmo se sobrepõe ao sinaldo analito. Valores de 1,0 pg e 0,6 ng g-1 foram obtidos respectivamente, para massa característica e limite de detecção, empregando-se irídio como modificador permanente e temperatura de pirólise de 600 ºC. Apesar de a técnica corrigir esse fundo pronunciado, parte do analito é aparentemente perdida durante a volatilização da matriz, fazendo com que o método não possa ser considerado robusto. / Iridium and ruthenium, alone and in combination with tungsten, thermally deposited on the platform of a transversely heated graphite tube, were investigated for their suitability as permanent chemical modifiers for the determination of cadmium in coal slurries by graphite furnace atomic absorption spectrometry (GF AAS). The conventional mixed palladium and magnesium nitrates (Pd-Mg) modifier, added in solution, was also investigated for comparison. The latter one showed the best performance for aqueous solutions, and the mixed W-Ir and W-Ru permanent modifiers had the lowest stabilizing power. All of the investigated modifiers lost some of their stabilizing power when coal slurries were investigated. The Pd-Mg modifier, pure Ir and Ru, and a mixture of 300 μg W + 200 μg Ir could stabilize Cd at least to a pyrolysis temperature of 600 ºC, whereas all the other combinations already failed at temperatures above 500-550 ºC. Additional investigations of the supernatant liquid of the slurries supported the assumption that the high acid concentration of the slurries and/or a concomitant leaching out of the coal might be responsible for the reduced stabilizing power of the modifiers. The maximum applicable pyrolysis temperature of 600 ºC was not sufficient to reduce the background absorption to a manageable level in the majority of the coal samples and higher pyrolysis temperatures cause loss of analyte. The following reference materials were used in this work: BCR No. 180 Gas Coal, SARM 18 Coal witbank, SARM 19 Coal O.F.S, SARM 20 Coal Sasolburg, NIST SRM 1635, NIST SRM 1630a and SRM. In addition, a coal sample from the Candiota mine in Rio Grande do Sul, Brazil, was investigated. Figures of merit were established and the values obtained for detection limit and characteristic mass were between 1.0 and 1.3 ng g-1 and 1.9 and 2.2 pg, respectively. In order to further investigate the spectral interference caused by the coal slurries, additional investigations were carried out using high resolution continuum source atomic absorption spectrometry. High-resolution continuum source ET AAS revealed that the continuous background absorption was beyond the capabilities of background correction exhibit by the deuterium background correction system, and was overlapping with the analyte signal. A characteristic mass of 1.0 pg and a detection limit of 0.6 ng g-1 could be obtained with iridium as permanent modifier and a pyrolysis temperature of 600 ºC. Although the technique could correct for thisbackground absorption, some analyte was apparently lost with the rapidly vaporizing matrix so that the method could not be considered to be rugged.
23

Uso de modificadores químicos permanentes na determinação de cádmio em suspensão de carvão por GF AAS convencional e de alta resolução

Bianchin, Liane January 2005 (has links)
Irídio e rutênio isoladamente e em combinação com tungstênio, termicamente depositados na plataforma de um tubo de grafite com aquecimento transversal, foram investigados quanto a sua aplicabilidade como modificadores permanentes para a determinação de cádmio em suspensões de carvão por espectrometria de absorção atômica com forno de grafite. O modificador químico de Pd-Mg adicionado em solução na forma de nitratos também foi investigado, para comparação. Este apresentou a melhor performance para solução aquosa, enquanto a mistura de W-Ir e W-Ru como modificadores permanentes apresentou o menor poder de estabilização. Todos os modificadores investigados perdem parte do seu poder de estabilização quando aplicados a suspensões de carvão. O modificador químico Pd-Mg e os modificadores permanentes Ir e Ru bem como a mistura de 300 μg de W e 200 μg de Ir estabilizam cádmio a uma temperatura de pirólise de 600 ºC, enquanto que as demais combinações investigadas permitem temperaturas de pirólise máximas entre 500 e 550 ºC. Investigações a partir da fase líquida das suspensões demonstram que existe a possibilidade de que a alta concentração de ácido empregada no preparo das suspensões e/ou compostos que são extraídos do carvão para a fase líquida podem ser responsáveis pela redução no poder de estabilização dos modificadores. A temperatura máxima de pirólise de 600 ºC não foi suficiente para reduzir a absorção de fundo provocada por concomitantes de algumas das amostras testadas, enquanto que temperaturas de pirólise mais elevadas levam à perda de analito. Para o desenvolvimento deste estudo, foram utilizados os materiais de referência BCR No 180 Gas Coal, SARM 18 Coal Witbank, SARM 19 Coal O.F.S., SARM 20 Coal Sasolburg, NIST SRM 1635, NIST SRM 1630a e SRM 1632b. Foi investigado também um carvão brasileiro da mina de Candiota no Rio Grande do Sul. Foram determinadas as figuras de mérito e os valores obtidos para o limite de detecção e a massa característica estão entre 1,0 e 1,3 ng g-1 e 1,9 e 2,2 pg, respectivamente. Estudos por espectrometria de absorção atômica de alta resolução com fonte contínua foram realizados com o intuito de elucidar as possíveis interferências provenientes de diferentes matrizes de carvão na forma de suspensão. Estes estudos revelaram que o fundo contínuo apresenta uma absorção maior do que a capacidade de correção exibida pelo corretor de deutério e que o mesmo se sobrepõe ao sinaldo analito. Valores de 1,0 pg e 0,6 ng g-1 foram obtidos respectivamente, para massa característica e limite de detecção, empregando-se irídio como modificador permanente e temperatura de pirólise de 600 ºC. Apesar de a técnica corrigir esse fundo pronunciado, parte do analito é aparentemente perdida durante a volatilização da matriz, fazendo com que o método não possa ser considerado robusto. / Iridium and ruthenium, alone and in combination with tungsten, thermally deposited on the platform of a transversely heated graphite tube, were investigated for their suitability as permanent chemical modifiers for the determination of cadmium in coal slurries by graphite furnace atomic absorption spectrometry (GF AAS). The conventional mixed palladium and magnesium nitrates (Pd-Mg) modifier, added in solution, was also investigated for comparison. The latter one showed the best performance for aqueous solutions, and the mixed W-Ir and W-Ru permanent modifiers had the lowest stabilizing power. All of the investigated modifiers lost some of their stabilizing power when coal slurries were investigated. The Pd-Mg modifier, pure Ir and Ru, and a mixture of 300 μg W + 200 μg Ir could stabilize Cd at least to a pyrolysis temperature of 600 ºC, whereas all the other combinations already failed at temperatures above 500-550 ºC. Additional investigations of the supernatant liquid of the slurries supported the assumption that the high acid concentration of the slurries and/or a concomitant leaching out of the coal might be responsible for the reduced stabilizing power of the modifiers. The maximum applicable pyrolysis temperature of 600 ºC was not sufficient to reduce the background absorption to a manageable level in the majority of the coal samples and higher pyrolysis temperatures cause loss of analyte. The following reference materials were used in this work: BCR No. 180 Gas Coal, SARM 18 Coal witbank, SARM 19 Coal O.F.S, SARM 20 Coal Sasolburg, NIST SRM 1635, NIST SRM 1630a and SRM. In addition, a coal sample from the Candiota mine in Rio Grande do Sul, Brazil, was investigated. Figures of merit were established and the values obtained for detection limit and characteristic mass were between 1.0 and 1.3 ng g-1 and 1.9 and 2.2 pg, respectively. In order to further investigate the spectral interference caused by the coal slurries, additional investigations were carried out using high resolution continuum source atomic absorption spectrometry. High-resolution continuum source ET AAS revealed that the continuous background absorption was beyond the capabilities of background correction exhibit by the deuterium background correction system, and was overlapping with the analyte signal. A characteristic mass of 1.0 pg and a detection limit of 0.6 ng g-1 could be obtained with iridium as permanent modifier and a pyrolysis temperature of 600 ºC. Although the technique could correct for thisbackground absorption, some analyte was apparently lost with the rapidly vaporizing matrix so that the method could not be considered to be rugged.
24

Desenvolvimento de nova metodologia para extração de cádmio (II) utilizando sistema de extração com membrana líquida renovável e detecção por espectrometria de absorção atômica em chama

Carletto, Jeferson Schneider 24 October 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências Físicas e Matemáticas, Programa de Pós-Graduação em Quimica, Florianópolis, 2009. / Made available in DSpace on 2012-10-24T14:30:32Z (GMT). No. of bitstreams: 1 275105.pdf: 1405556 bytes, checksum: dc4368431d8c2a68762e7f4f84fe400c (MD5) / A hollow fiber renewal liquid membrane (HFRLM) extraction method for determination of cadmium(II) in water samples by Flame Atomic Absorption Spectrometry (FAAS) was developed. Ammonium O,O-diethyl dithiophosphate (DDTP) was used to complex cadmium(II) in an acid pH into a neutral hydrofobic complex (ML2). A solvent extract this complex and carry it over the Poly(dimethylsiloxane) (PDMS) or polypropylene membrane to the stripping phase into the membrane, where at higher pH the complex Cd-DDTP is broken out and cadmium(II) is released into the stripping phase. EDTA was used to complex cadmium(II) helping to trap the analyte into the stripping phase. Multivariate optimization using surface response metodology was used to optimize the studied variables: sample (donor phase) pH 3.25, DDTP concentration 0.05% (m/v), stripping (aceptor phase) pH 8.75, EDTA concentration 1.5x10-2 mol L-1, extraction temperature 40°C, extraction time 40 minutes, a solvent mixture of N-Butyl Acetate and Hexane (60/40% v/v) with volume of 100 ìL and adition of ammonium sulphate to saturate the sample for PDMS membrane. For polypropylene membrane the optimized conditions were: sample (donor phase) pH 3.5, DDTP concentration 0.06% (m/v), stripping (aceptor phase) pH 9.0, EDTA concentration 6.3 x 10-3 mol L-1, extraction temperature 36°C, extraction time 36 minutes, toluene as solvent extractor with volume of 300 ìL and adition of ammonium sulphate to saturate the sample. The sample volume and stripping volume used were 20 mL and 165 ìL, respectivaly. The analyte enrichment factor was 115, limit of detection (LOD) 1.3 ìg L-1, relative standard deviation (RSD) 5.5 % and linear working range 4.5 - 30 ìg L-1 for PDMS membrane. For polypropylene membrane the analyte enrichment factor was 107, limit of detection (LOD) 1.5 ìg L-1, relative standard deviation (RSD) 4 % and linear woking range 5.1 - 30 ìg L.
25

Determinação de elementos traço em diesel e biodiesel por espectrometria de absorção atômica de alta resolução com fonte contínua e atomização eletrotérmica

Quadros, Daiane Paula Cunha de January 2011 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências Físicas e Matemáticas, Programa de Pós-Graduação em Química, Florianópolis, 2011 / Made available in DSpace on 2012-10-25T22:23:31Z (GMT). No. of bitstreams: 1 289610.pdf: 866294 bytes, checksum: 532f7e63a97238dd39c594db0bd5da30 (MD5)
26

Desenvolvimento de método analítico para determinação de metais em biodiesel e óleo vegetal por espectometria de absorção atômica com chama

Jesus, Alexandre de January 2008 (has links)
Os metais sódio, potássio, magnésio e cálcio podem danificar a estabilidade do biodiesel, pois tendem a reagir com ésteres e produzir sabão. Neste trabalho foi desenvolvido um método para a determinação desses metais em amostras de biodiesel e óleo vegetal, através da microemulsificação das amostras e determinação por espectrometria de absorção atômica com chama (F AAS). Amostras de biodiesel obtidas de diferentes fontes e de óleo vegetal foram analisadas. Foram obtidas microemulsões do tipo óleo-em-água pela mistura de biodiesel ou óleo vegetal, um surfactante, água e um co-surfactante. Na fase aquosa das microemulsões, foram adicionados HNO3 diluído e padrões inorgânicos dos metais para calibração. Vantagens em relação ao método de diluição com solvente, que é o método oficial adotado para as determinações (método de referência) foram observadas, tais como: maior estabilidade dos analitos no meio microemulsificado, possibilidade de calibração usando padrões aquosos nas microemulsões, limites de quantificação melhores e não utilização de solventes orgânicos carcinogênicos. Os resultados obtidos pelo método proposto foram concordantes com os resultados obtidos pelo método de referência, tornando assim o novo método uma eficiente alternativa para a determinação de metais em biodiesel, além de suprir as deficiências apresentadas pelo método de diluição com solvente. / The metals sodium, potassium, magnesium and calcium can damage biodiesel stability because these metals tend to react with esters and produce soap. In this work a method was developed for the determination of these metals in biodiesel and vegetable oil samples, through microemulsification of the samples and determination by flame atomic absorption spectrometry (F AAS). Biodiesel samples obtained from different sources and vegetable oil samples were analyzed. The water-in-oil microemulsion systems were obtained mixing biodiesel, a surfactant, water and a co-surfactant. Inorganic standards were added within the water portion to prepare the microemulsions used for calibration and nitric acid. The proposed method was compared with the method adopted by Brazilian’s regulations of dilution with organic solvent (reference method) for these determinations and some advantages were observed, as: higher stability of analytes in the microemulsions, feasibility of calibration using aqueous standards in the microemulsions, better limits of quantification and no use carcinogenic solvents. The results obtained by the new proposed method were a good agreement with the results obtained by the reference method. The new proposed method was an efficient alternative for the determination of metals in biodiesel, and overcome some deficiencies presented by the dilution method.
27

Espectrometria de ansorção atômica de alta resolução com fonte contínua como ferramenta analítica para o desenvolvimento de método para determinação de níquel e vanádio por espectrometria de absorção atômica em forno de grafite em amostras de óleo cru

Lepri, Fábio Grandis January 2005 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências Físicas e Matemáticas. Programa de Pós-Graduação em Química. / Made available in DSpace on 2013-07-16T02:46:04Z (GMT). No. of bitstreams: 1 242932.pdf: 655625 bytes, checksum: cb4ba88d1cd423bf1f47453296285b3d (MD5)
28

Desenvolvimento de métodos analíticos para a determinação de mercúrio e selênio utilizando técnicas de geração de vapor acopladas à espectrometria de absorção atômica com forno de grafite

Potes, Mariana da Luz January 2018 (has links)
A geração química de vapor (CVG) e a geração fotoquímica de vapor (PVG) são técnicas analíticas empregadas na conversão do analito, presente na fase condensada, em uma espécie volátil, previamente a sua introdução no sistema de detecção. Neste trabalho foram desenvolvidos procedimentos analíticos para a determinação de Hg e Se em amostras biológicas por técnicas de geração de vapor acopladas à espectrometria de absorção atômica com forno de grafite (GF AAS). A determinação exata e precisa de Hg em amostras de peixe foi possível após a solubilização em hidróxido de tetrametilamônio e adição de n-propanol, como composto orgânico de baixo peso molecular, e detecção por PVG-GF AAS. O método analítico desenvolvido com o emprego da técnica de PVG para a determinação de Se em água de coco por GF AAS resultou em limites de detecção e quantificação de 0,65 μg L-1 e 2,2 μg L-1, respectivamente, os quais foram semelhantes aos obtidos por CVG. Os métodos desenvolvidos para a determinação de Hg e Se por PVG-GF AAS em amostras biológicas são sensíveis, livres de interferência espectral, de baixo custo e representam uma alternativa viável a CVG. / Chemical vapor generation (CVG) and photochemical vapor generation (PVG) are analytical techniques used to convert the analyte into a volatile species in liquid phase, before the introduction into the detection system. In this study, analytical procedures for the determination of Hg and Se in biological samples by vapor generation techniques coupled to graphite furnace atomic absorption spectrometry (GF AAS) were developed. Accurate Hg determination in fish samples was possible after a solubilization in tetramethylammonium hydroxide and adding n-propanol, as low molecular organic compound, using PVG-GF AAS. The developed method for Se determination in coconut water with PVG-GF AAS have resulted in limits of detection and quantification of 0,65 μg L-1 and 2,2 μg L-1, respectively and that were similar with those obtained with CVG. The developed methods for Hg and Se determination in biological samples using PVG-GF AAS are sensitive, free of spectral interference, low-cost, and are a feasible alternative for CVG.
29

Estratégias analíticas para determinação sequencial de metais em vinhos por espectrometria de absorção atômica de alta resolução com fonte contínua por chama

Boschetti, Wiliam January 2012 (has links)
Neste trabalho foi desenvolvido e otimizado um método para determinação sequencial rápida por espectrometria de absorção atômica de alta resolução com fonte contínua por chama (HR-CS FS-FAAS) de metais em amostras de vinhos, produzidos em diferentes regiões do Brasil. As amostras foram obtidas de 8 regiões brasileiras diferentes: Serra Gaúcha, Vale dos Vinhedos, Pinto Bandeira, Campos de Cima da Serra, Campanha Gaúcha, Serra Catarinense, Oeste do Paraná e Vale do São Francisco. Os elementos avaliados foram: Be, Ca, Co, Cu, K, Li, Mn, Na, Rb e Sr. Estes metais têm grande importância nas propriedades organolépticas do vinho, assim como para produção de uvas de qualidade. A validação do método foi feita pelo estabelecimento de curvas de calibração, realização de ensaios de recuperação e comparação dos resultados encontrados por HR-CS FS-FAAS com aqueles obtidos por espectrometria de emissão óptica com plasma acoplado indutivamente (ICP OES). Padrões aquosos foram utilizados para a calibração e o coeficiente de correlação encontrado, para todos os analitos avaliados, foi maior que 0,9994. A partir das curvas de calibração os limites de detecção foram calculados para cada elemento: 44 μg L-1 para Cu, 5,0 μg L-1 para Li, 20 μg L-1 para Rb, 42 μg L-1 para Mn, 58 μg L-1 para Co, 15 μg L-1 para Sr, 23 μg L-1 para Be, 0,90 mg L-1 para Na, 4,4 mg L-1 para K e 0,92 mg L-1 para Ca. Ensaios de recuperação para cada analito foram realizados, encontrando recuperações entre 91 e 111%. A partir dos resultados encontrados, fazendo-se uso das técnicas de reconhecimento de padrões Análise por Componentes Principais (PCA) e Análise por Agrupamento Hierárquico (HCA) foi observada a formação de 7 grupos distintos, quando empregados os teores de K, Mn, Rb e Sr, dentre os 8 grupos (regiões do Brasil) avaliados. Com este conjunto de informações, portanto, é possível o monitoramento de fraudes e da qualidade do vinho produzido em cada região produtora. / In this work a method has been developed for the determination of metals in wine samples, produced in different regions of Brazil, using high-resolution continuum source fastsequential flame atomic absorption spectrometry (HR-CS FS-FAAS). The samples were obtained from eight different regions: Serra Gaúcha, Vale dos Vinhedos, Pinto Bandeira, Campos de Cima da Serra, Campanha Gaúcha, Serra Catarinense, Oeste do Paraná e Vale do São Francisco. The investigated elements were: Be, Ca, Co, Cu, K, Li, Mn, Na, Rb and Sr. These metals are important for the organoleptic properties of wine and for the production of grapes. The method was validated by recovery tests and comparison between the results obtained by HR-CS FS-FAAS and inductively coupled plasma optical emission spectrometry (ICP OES). Aqueous standards were used for calibration and the correlation coefficient found was higher than 0.9994 for all investigated elements. The detection limits were calculated from the calibration curves for each analyte: 44 μg L-1 for Cu, 5.0 μg L-1for Li, 20 μg L-1 for Rb, 42 μg L-1 for Mn, 58 μg L-1 for Co, 15 μg L-1 for Sr, 23 μg L-1 for Be, 0.90 mg L-1 for Na, 4.4 mg L-1 for K and 0.92 mg L-1 for Ca. The recovery tests showed results between 91 and 111%. After method validation the samples were evaluated. With the results obtained and using pattern recognition techniques Principal Component Analysis (PCA) and Hierarchical Cluster Analysis (HCA) was possible to find seven different groups, evaluating K, Mn, Rb and Sr concentration values, among the eight original groups (Brazilian regions) evaluated. Finally, using all the information obtained in this work, it’s possible to control frauds and the wine produced quality.
30

Determinação de elementos traço em carvão por espectrometria de absorção atômica de alta resolução com fonte contínua e por espectrometria de massa com plasma indutivamente acoplado e vaporização eletrotérmica

Borges, Daniel Lázaro Gallindo January 2005 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências Físicas e Matemáticas. Programa de Pós-Graduação em Química. / Made available in DSpace on 2013-07-15T23:13:45Z (GMT). No. of bitstreams: 1 228645.pdf: 621379 bytes, checksum: 233534c8262dbe43d103dbd7b1d98d58 (MD5) / Neste trabalho, o desenvolvimento de método para determinação de Cd e Pb por espectrometria de absorção atômica de alta resolução com fonte contínua com introdução direta da amostra sólida (SS-HR-CS AAS) e para determinação de As, Cd, Pb e Tl por espectrometria de massa com plasma indutivamente acoplado e vaporização eletrotérmica (ETV-ICP-MS) é demonstrado para a análise de amostras certificadas de referência de carvão. Para a amostragem direta de sólidos com análise por HR-CS AAS, as amostram foram moídas e inseridas em alíquotas de massa de 0,6 a 1 mg. Temperaturas de pirólise inferiores a 600 ºC geram fundo contínuo devido à eliminação incompleta da matriz e temperaturas elevadas de atomização propiciam o aparecimento de fundo estruturado. Após calibração contra padrões aquosos em HNO3 0,5% v/v, a determinação foi realizada com uso de Ir como modificador permanente para Cd e sem uso de modificador para Pb, resultando em boa concordância entre valores de referência e valores determinados. Para análise por ETV-ICP-MS, as suspensões (5 mg mL-1) foram preparadas em HNO3 5% v/v. Temperatura de pirólise e vaporização e a vazão dos gases interno e carreador foram otimizados. Ru foi adicionado em solução, agindo como modificador e como carreador do aerossol. Após calibração externa com padrões aquosos, bons resultados foram obtidos na análise dos materiais de referência.

Page generated in 0.1259 seconds