• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Investigation and Validation of Cooling Loss Models for Axial Gas Turbines

Händestam, Jacob, Jacobson, Eric January 2017 (has links)
Detta arbete behandlar undersökningen och valideringen av kylförlustmodellen i det nyligen framtagna programmet för endimensionell turbindesign, Mean Line Tool (MLT), skapat av Siemens Industrial Turbomachinery AB (SIT). Huvudsyftet är att undersöka med vilken noggrannhet MLT kan prediktera de extra aerodynamiska förluster som uppstår vid injektion av kylluft i en turbinpassage. För att validera kylförlustmodellen i MLT, har tidigare resultat från en testrigg på KTH används, där de extra förlusterna på grund av kylinjektion har mätts för ett flertal kylpositioner på en turbinledskena. Lokala flödes- och geometriska parametrar från testriggen ansattes i MLT för att möjliggöra en korrekt jämförelse. Ytterligare validering utfördes mot en testbaserad Siemens-korrelation, som är en sammanställning av ett flertal test från olika turbinkomponenter av SIT. I denna korrelation undersöktes kylning på en ledskenas bladprofil och plattform, samt på skovelns bladprofil, där en ökning av kylmassflöde relaterades till en förändring i stegverkningsgrad. Resultaten, från jämförelsen mellan data från testriggen på KTH samt beräkningar i MLT, visade att MLT predikterar extraförlusterna på grund av kylning på bladprofilen av en ledskena med bra noggrannhet. Däremot visar jämförelsen att MLT beräknar en lägre förlust för bakkantskylning. Således har en modifierad förlustkorrelation för bakkantskylning presenterats, som ger mer överensstämmande resultat mot testriggen. Jämförelsen mellan MLT beräkningar och den testbaserade Siemens-korrelationen visar att MLT inte predikterar förändringen i stegverkningsgrad, på grund av extra kylmassflöde, med bra noggrannhet. På grund av ett flertal osäkerheter har denna jämförelse endast användas för att kvalitativt belysa brister i kylförlustmodellen av MLT. Med detta i åtanke har det fastställts att plattformskylning vid främre delen av en turbinpassage skulle kunna vara mycket överpredikterad av MLT. Den övergripande slutsatsen är att MLT predikterar förändringen i gitterverkningsgrad på grund av kylning på en ledskenas bladprofil med bra noggrannhet, förutom bakkantskylning. Ytterligare jämförelser visar att MLT inte kan prediktera förändringen i stegverkningsgrad, på grund av extra kylmassflöde, med bra noggrannhet för olika kylda komponenter från gasturbinsportfolion av SIT. Således behövs vidare validering av MLT innan programmet kan implementeras i turbindesignsystemet av SIT. / This thesis concerns the investigation and validation of the cooling loss model in newly developed one-dimensional turbine design tool, Mean Line Tool (MLT), of Siemens Industrial Turbomachinery AB (SIT). The main objective is to investigate how accurately MLT can predict the additional aerodynamic losses due to cooling ejection in a turbine blade passage. To validate the cooling loss model of MLT, existing results from an annular sector cascade rig at KTH were used, where the additional losses due to cooling ejection were presented for several cooling locations on a stator vane profile. Local flow- and geometrical parameters from the cascade rig were set in MLT to enable a fair comparison. Moreover, a Siemens test based correlation was used, which is a data collection based on tests using various cooled components of SIT. Cooling ejection on a stator vane profile, stator vane platform and rotor blade profile was investigated, where an increase in coolant mass-flow was related to a change in stage efficiency. The results, when comparing data from the KTH cascade rig against calculations of MLT, show that MLT is able to accurately predict the additional loss due to cooling ejection on a stator vane profile. However, the comparison presents that the calculated loss for trailing edge cooling by MLT is lower than the results from the cascade rig. Therefore, a modified trailing edge cooling correlation is presented, which predicts the results from the cascade rig with better accuracy. Furthermore, comparisons between MLT calculations and the Siemens correlation present that MLT cannot predict the change in stage efficiency, due to added coolant mass-flow, accurately. However, due to several uncertainties, these results are qualitatively used to understand sources of prediction error in the cooling loss model of MLT. Having this in mind, it is established that hub platform cooling at the front part of a blade passage might be greatly overpredicted by MLT. The general conclusion is that MLT predicts the change in cascade efficiency due to coolant ejection with good accuracy for a stator vane profile, except for cooling at the trailing edge. However, MLT is not able to predict the change in stage efficiency, due to added coolant mass-flow, with good accuracy for various cooled components from the SIT gas turbine product portfolio. Thus, MLT needs further validation before it can be implemented into the SIT design system.

Page generated in 0.1135 seconds