• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • 3
  • Tagged with
  • 8
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Analys av vävnadsprover med endimensionell elektrofores

Larsson, Frida January 2007 (has links)
<p>The following project has been made in collaboration with, Denator AB, a biotechnology enterprise. One-dimensional electrophoreses have been used to analyze protein contents of tissue samples. Tissue samples have been either treated according to the company´s newly developed tissue treatment technique or not treated at all and comparisons between these samples have been made. In order to see differences in protein patterns between samples more clearly, a conversion method has been developed where electrophoresis gel visual patterns are used to produce curves, similar to densitometer curves.</p><p>Denator AB would like to know if the proteins in their treated samples will change visibly over 48 h when incubated at room temperature. This has been investigated using the above mentioned method. A comparison has also been made using untreated samples incubated in the same way.</p><p>The analyses have been made at two gel densities, 10% and 12%. The series of samples consisted of both treated and untreated samples. Incubations were made for different time intervals in room temperature, up to 48 h. Gels were scanned and the files were used for producing curves where the colour intensity along a track was used for ordinate and the protein travel distance was used for abscissa.</p><p>Using this method, no change in patterns of Denator treated samples could be seen, strongly indicating efficient conservation of the samples. The untreated samples, however, show visible changes with time, indicating that the sample proteins were</p><p>partly decomposed into smaller fragments with time. A striking result of the analyses is a clearly visible difference in the original patterns of untreated and treated samples before incubation. This indicate that non treated samples undergo a very quick process of decay.</p>
2

Analys av vävnadsprover med endimensionell elektrofores

Larsson, Frida January 2007 (has links)
The following project has been made in collaboration with, Denator AB, a biotechnology enterprise. One-dimensional electrophoreses have been used to analyze protein contents of tissue samples. Tissue samples have been either treated according to the company´s newly developed tissue treatment technique or not treated at all and comparisons between these samples have been made. In order to see differences in protein patterns between samples more clearly, a conversion method has been developed where electrophoresis gel visual patterns are used to produce curves, similar to densitometer curves. Denator AB would like to know if the proteins in their treated samples will change visibly over 48 h when incubated at room temperature. This has been investigated using the above mentioned method. A comparison has also been made using untreated samples incubated in the same way. The analyses have been made at two gel densities, 10% and 12%. The series of samples consisted of both treated and untreated samples. Incubations were made for different time intervals in room temperature, up to 48 h. Gels were scanned and the files were used for producing curves where the colour intensity along a track was used for ordinate and the protein travel distance was used for abscissa. Using this method, no change in patterns of Denator treated samples could be seen, strongly indicating efficient conservation of the samples. The untreated samples, however, show visible changes with time, indicating that the sample proteins were partly decomposed into smaller fragments with time. A striking result of the analyses is a clearly visible difference in the original patterns of untreated and treated samples before incubation. This indicate that non treated samples undergo a very quick process of decay.
3

Den nya rationella skolan : - En teoriprövande studie av den nya läroplanen utifrån Habermas rationalitetsbegrepp

Fält, Rolf January 2012 (has links)
Denna studie behandlar den nya läroplanen för grundskolan utifrån samhällskritisk teori. Marcuse och Habermas verk bidrar med det grundläggande teoretiska perspektivet för studien med tesen att det sker en omfattande likriktning i samhället där allt fler värden kan omvärderas och rationaliseras utifrån ett ekonomiskt perspektiv, det vill säga en marknadens logik blir allt oftare det enda rådande sättet att beskåda verkligheten från. För att beskriva denna logiks hegemoni över samhället använder Habermas termen ”den endimensionella rationaliteten”. Studien ställer frågorna huruvida förändringarna av grundskolans läroplan kan sammankopplas till en endimensionell rationalitet och om det går att urskilja idéerna bakom några av de etablerade organisationsteorierna, som grovt talat utgör en rationell handlingsmall. Analysen av läroplanerna kan avslöja flera tydliga kopplingar till olika organisationsteorier och en klar tendens mot likriktning går att urskilja i den nya läroplanen i förhållande till den gamla. Strävansmål och individuell utveckling har ersatts med detaljstyrt centralt innehåll och kunskapskrav. Bland annat återfinns en utökad standardisering, centralisering och kontroll över skolan som är förenlig med traditionella organisationsteorier. Studien vill varna för att konsekvenserna av ett instrumentellt förhållande till kunskap i skolan mycket väl kan bli dramatiska då det hämmar kreativitet och lust för lärandet. Faktorer som istället bör vara i centrum för att driva Sverige som kunskapssamhälle framåt genom den globala konkurrensen.
4

Den nya rationella skolan : En teoriprövande studie av den nya läroplanen utifrån Habermas rationalitetsbegrepp

Fält, Rolf January 2012 (has links)
Denna studie behandlar den nya läroplanen för grundskolan utifrån samhällskritisk teori. Marcuse och Habermas verk bidrar med det grundläggande teoretiska perspektivet för studien med tesen att det sker en omfattande likriktning i samhället där allt fler värden kan omvärderas och rationaliseras utifrån ett ekonomiskt perspektiv, det vill säga en marknadens logik blir allt oftare det enda rådande sättet att beskåda verkligheten från. För att beskriva denna logiks hegemoni över samhället använder Habermas termen ”den endimensionella rationaliteten”. Studien ställer frågorna huruvida förändringarna av grundskolans läroplan kan sammankopplas till en endimensionell rationalitet och om det går att urskilja idéerna bakom några av de etablerade organisationsteorierna, som grovt talat utgör en rationell handlingsmall. Analysen av läroplanerna kan avslöja flera tydliga kopplingar till olika organisationsteorier och en klar tendens mot likriktning går att urskilja i den nya läroplanen i förhållande till den gamla. Strävansmål och individuell utveckling har ersatts med detaljstyrt centralt innehåll och kunskapskrav. Bland annat återfinns en utökad standardisering, centralisering och kontroll över skolan som är förenlig med traditionella organisationsteorier. Studien vill varna för att konsekvenserna av ett instrumentellt förhållande till kunskap i skolan mycket väl kan bli dramatiska då det hämmar kreativitet och lust för lärandet. Faktorer som istället bör vara i centrum för att driva Sverige som kunskapssamhälle framåt genom den globala konkurrensen.
5

Analys hur de svenska politikprogrammen förändrats över tid : Ett långsiktigt perspektiv / An analysis about how the political programs have changed over time : A long-term perspective

Pantzar, Emma January 2018 (has links)
Syftet med studien är att analysera förändringen i de svenska partiernas politiska program genom att tillämpa Public Choice skolans modeller. Med hjälp av medianväljarteoremet och Hotellingmodellen analyseras om modellerna är tillräckligt beskrivande för Sveriges partiförflyttningar. Vidare beräknas Herfindahl-Hirschman index för graden av maktkoncentration på den politiska ”marknaden”. Herfindahl-Hirschman indexet visar att koncentrationen på den politiska marknad blivit lägre över tid, viket indikerar på att konkurrensen mellan partierna blivit allt högre under perioden 1973-2014. För att analysera om det går att förklara förändringar i partiernas politik under perioden 1973-2014 tillämpas medianväljarteoremet. En diskussion kring testning av modellen görs samt en illustration hur medianväljarteoremet skulle kunna se ut för Sveriges partier. För att analysera om en endimensionell skala är beskrivande för de svenska partiernas förflyttningar har Hotellingmodellen tillämpats. Genom att illustrera dessa två modeller på Sveriges partier undersöks om modellerna ger en tillfredställande beskrivningar av förändringen i de svenska partiernas politiska program. Analysen ger vid handen att att Medianväljarmodellen inte förklarar förändringarna i partiernas politik på ett tillräckligt utförligt sätt. Hotellingmodellen kan bättre förklar både de svenska partiernas förflyttningar på vänster-högerskalan samt förändringar i partiernas politik. Utöver de nämnda modellerna konstateras att den enskilda faktor som är mest betydelsefull för hur partierna ändrat sina politiska program är partiernas beroende av väljarnas åsikter. / The aim of the study is to analyze changes in the Swedish political parties programs by applying the Public Choice approach. With help from the median voter theorem and the Harold Hotelling model, the paper analyzes if these models are sufficiently descriptive of Swedens political parties movements. A Herfindahl-Hirschman index is constructed which shows changes in concentration of political power over time. The Herfindahl-Hirschman index shows that the degree of concentration in the Swedish political “market” has become lower over time, which indicates that the party competition has increased during the period 1973-2014. In order to analyze whether it is possible to explain changes in the parties’ policies during the period 1973-2014 the median voter theorem is applied. A discussion about how this model can be tested is done as well as an illustration of how the median voter theorem could look like for the parties in Sweden. To analyze whether a one-dimensional scale is descriptive of the movements of the Swedish parties, the Harold Hotelling model is also applied. By illustrating these two models on Swedens parties, the paper investigates whether these models provide a satisfactory descriptions of the change in the Swedish parties political programs. The analysis concludes that the median voter theorem does not explain the changes in the parties politics in a sufficiently detailed manner. It is revealed that the Harold Hotelling model provides a better description for both the Swedish parties movements at the left-right scale and for the changes in the parties politics. In addition to the models mentioned the factor that that is most important for how the parties changed their political programs is the parties’ dependence of the voters opinions.
6

Evaluation of Shunt Distance in Resistance Spot Welding

Fredriksson, Daniel, Carlfors Göransson, Milou January 2020 (has links)
The purpose of this study was to generate a greater understanding of how the shunt distance affects the shunting phenomena which occurs when working with resistance spot welding (RSW). Shunting affects the quality of the weld and the goal of the study was to create guidelines for RSW to minimize its impact on the weld quality. In order to minimize waste from production and to reduce the welding time there is need for understanding of what the shunt effect depends on. To evaluate what impact the shunt distance will have on the weld, two different experiments were performed. In the first experiment, a one-dimensional welding lobe was manufactured for various materials and the current range was compared over three different shunt distances. The second experiment consisted of welding with a constant current on different shunt distances to investigate how this would impact the second weld performed in the welding sequence. A range of different steel grades and sheet thicknesses was used in the experiments to further explore what impact different material properties will have on the shunt effect. The result showed that the shunt distance has little impact on the acceptable weld-current range, with minor deviations. However, the shunt distance will affect the size of the shunted weld, which decreases as the shunt distance is reduced. Overall, the data collected in this study is not expansive enough to make guidelines that could be implemented in today´s industry. The phenomena of shunting require more data to fully be understood. / Syftet med denna studie var att skapa en större förståelse för hur shuntavståndet påverkar det shunt-fenomen som uppstår när man arbetar med punktsvetsning (RSW). Shuntning påverkar svetsens kvalitet och målet var att skapa riktlinjer för arbete med RSW för att minimera shunt-effektens påverkan på svetsen. I syfte att kunna minimera spill i produktionen samt att minska svetstiden krävs det förståelse av vad shunt effekten beror på. För att utvärdera vilken påverkan shuntavståndet kommer att ha på svetsen utfördes två olika experiment. I det första experimentet skapades en endimensionell svetslob för varje material och det genererade strömintervallet jämfördes över tre olika shuntavstånd. Det andra experimentet bestod av svetsning med en lika stor ström vid olika shuntavstånd för att undersöka hur detta skulle påverka den andra svetsen. En rad olika stålsorter och plåttjocklekar användes för att ytterligare se vilken påverkan dessa faktorer kom att ha på shunteffekten. Resultatet visade att shuntavståndet hade liten inverkan på det acceptabla svetsströmintervallet, med mindre avvikelser. Emellertid påverkar shuntavståndet storleken på den shuntade svetsen genom att storleken minskar när shuntavståndet minskas. Sammantaget räcker inte de uppgifter som samlats in i denna studie för att skapa riktlinjer som skulle kunna implementeras i dagens industri, utan det krävs mer data för att fullständigt kartlägga shunteffekten.
7

Investigation and Validation of Cooling Loss Models for Axial Gas Turbines

Händestam, Jacob, Jacobson, Eric January 2017 (has links)
Detta arbete behandlar undersökningen och valideringen av kylförlustmodellen i det nyligen framtagna programmet för endimensionell turbindesign, Mean Line Tool (MLT), skapat av Siemens Industrial Turbomachinery AB (SIT). Huvudsyftet är att undersöka med vilken noggrannhet MLT kan prediktera de extra aerodynamiska förluster som uppstår vid injektion av kylluft i en turbinpassage. För att validera kylförlustmodellen i MLT, har tidigare resultat från en testrigg på KTH används, där de extra förlusterna på grund av kylinjektion har mätts för ett flertal kylpositioner på en turbinledskena. Lokala flödes- och geometriska parametrar från testriggen ansattes i MLT för att möjliggöra en korrekt jämförelse. Ytterligare validering utfördes mot en testbaserad Siemens-korrelation, som är en sammanställning av ett flertal test från olika turbinkomponenter av SIT. I denna korrelation undersöktes kylning på en ledskenas bladprofil och plattform, samt på skovelns bladprofil, där en ökning av kylmassflöde relaterades till en förändring i stegverkningsgrad. Resultaten, från jämförelsen mellan data från testriggen på KTH samt beräkningar i MLT, visade att MLT predikterar extraförlusterna på grund av kylning på bladprofilen av en ledskena med bra noggrannhet. Däremot visar jämförelsen att MLT beräknar en lägre förlust för bakkantskylning. Således har en modifierad förlustkorrelation för bakkantskylning presenterats, som ger mer överensstämmande resultat mot testriggen. Jämförelsen mellan MLT beräkningar och den testbaserade Siemens-korrelationen visar att MLT inte predikterar förändringen i stegverkningsgrad, på grund av extra kylmassflöde, med bra noggrannhet. På grund av ett flertal osäkerheter har denna jämförelse endast användas för att kvalitativt belysa brister i kylförlustmodellen av MLT. Med detta i åtanke har det fastställts att plattformskylning vid främre delen av en turbinpassage skulle kunna vara mycket överpredikterad av MLT. Den övergripande slutsatsen är att MLT predikterar förändringen i gitterverkningsgrad på grund av kylning på en ledskenas bladprofil med bra noggrannhet, förutom bakkantskylning. Ytterligare jämförelser visar att MLT inte kan prediktera förändringen i stegverkningsgrad, på grund av extra kylmassflöde, med bra noggrannhet för olika kylda komponenter från gasturbinsportfolion av SIT. Således behövs vidare validering av MLT innan programmet kan implementeras i turbindesignsystemet av SIT. / This thesis concerns the investigation and validation of the cooling loss model in newly developed one-dimensional turbine design tool, Mean Line Tool (MLT), of Siemens Industrial Turbomachinery AB (SIT). The main objective is to investigate how accurately MLT can predict the additional aerodynamic losses due to cooling ejection in a turbine blade passage. To validate the cooling loss model of MLT, existing results from an annular sector cascade rig at KTH were used, where the additional losses due to cooling ejection were presented for several cooling locations on a stator vane profile. Local flow- and geometrical parameters from the cascade rig were set in MLT to enable a fair comparison. Moreover, a Siemens test based correlation was used, which is a data collection based on tests using various cooled components of SIT. Cooling ejection on a stator vane profile, stator vane platform and rotor blade profile was investigated, where an increase in coolant mass-flow was related to a change in stage efficiency. The results, when comparing data from the KTH cascade rig against calculations of MLT, show that MLT is able to accurately predict the additional loss due to cooling ejection on a stator vane profile. However, the comparison presents that the calculated loss for trailing edge cooling by MLT is lower than the results from the cascade rig. Therefore, a modified trailing edge cooling correlation is presented, which predicts the results from the cascade rig with better accuracy. Furthermore, comparisons between MLT calculations and the Siemens correlation present that MLT cannot predict the change in stage efficiency, due to added coolant mass-flow, accurately. However, due to several uncertainties, these results are qualitatively used to understand sources of prediction error in the cooling loss model of MLT. Having this in mind, it is established that hub platform cooling at the front part of a blade passage might be greatly overpredicted by MLT. The general conclusion is that MLT predicts the change in cascade efficiency due to coolant ejection with good accuracy for a stator vane profile, except for cooling at the trailing edge. However, MLT is not able to predict the change in stage efficiency, due to added coolant mass-flow, with good accuracy for various cooled components from the SIT gas turbine product portfolio. Thus, MLT needs further validation before it can be implemented into the SIT design system.
8

Aerothermal and Kinetic Modelling of a Gas Turbine Dry Low Emission Combustion System / Aerotermisk och kinetisk modellering av en gasturbins "dry low emission" - förbränningssystem

Håkansson, David January 2021 (has links)
Growing environmental concerns are causing a large transformation within the energy industry. Within the gas turbine industry, there is a large drive to develop improved modern dry-low emission combustion systems. The aim is to enable gas turbines to run on green fuels like hydrogen, while still keeping emission as NOx down. To design these systems, a thorough understanding of the aerothermal and kinetic processes within the combustion system of a gas turbine is essential. The goal of the thesis was to develop a one-dimensional general network model of the combustion system of Siemens Energy SGT-700, which accurately could predict pressure losses, mass flows, key temperatures, and emissions. Three models were evaluated and a code that emulated some aspects of the control system was developed. The models and the code were evaluated and compared to each other and to test data from earlier test campaigns performed on SGT-700 and SGT-600. Simulations were also carried out with hydrogen as the fuel.  In the end, a model of the SGT-700 combustion chamber was developed and delivered to Siemens Energy. The model had been verified against test data and predictions made by other Siemens Energy thermodynamic calculation software, for a range of load conditions. The preforms of the model, when hydrogen was introduced into the fuel mixture, were also tested and compared to test data / En växande medvetenhet kring klimatfrågan, har medfört stora förändringar i energibranschen. I och med detta behöver även gasturbinindustrin förbättra de nuvarande dry-low emissions systemen och göra det möjligt för gasturbiner att förbränna gröna bränslen som väte. Samtidigt måste också utsläppen av NOx hållas nere. För att kunna utforma dessa system behövs en fullständig förståelse för de aerotermiska och kinetiska processerna i en gasturbins förbränningskammare. Målet med detta examensarbete var att utveckla en endimensionell generell nätverksmodell för förbränningssystemet i Siemens Energys SGT-700. Modellen skulle noggrant kunna förutsäga tryckförluster, massflöden, viktiga temperaturer samt utsläpp. Tre modeller utvärderades och en kod som emulerade vissa aspekter av styrsystemet utvecklades också. Modellerna och koden utvärderades och jämfördes mot varandra och även mot testdata från tidigare testserier som utfördes på SGT-700 och SGT-600. Simuleringar utfördes också med väte som bränsle. Slutligen levererades en modell av SGT-700 förbränningskammaren till Siemens Energy. Modellen har verifierats för en rad olika lastfall, mot testdata och data som genererats av andra termodynamisk beräkningsprogram som utvecklats av Siemens Energy. Hur modellen uppförde sig när väte var introducerat in i olika lastfall jämfördes också mot testdata

Page generated in 0.1107 seconds