• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 488
  • 7
  • 6
  • 6
  • 6
  • 6
  • 4
  • 4
  • 4
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 510
  • 370
  • 362
  • 357
  • 353
  • 292
  • 287
  • 273
  • 122
  • 68
  • 58
  • 53
  • 53
  • 52
  • 45
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Aplicação do modo de nanolitografia de um microscópio de força atômica para a estruturação de superfícies

Carreira, Willian Hasenkamp January 2007 (has links)
Neste trabalho, estudamos o processo de nanoestruturação de superfícies por microscopia de força atômica. O processo de indução mecânica de deformações foi abordado sob o enfoque de duas técnicas: a aragem dinâmica e a aragem estática. Essas técnicas foram aplicadas para nanoestruturar diferentes materiais (polímeros e metais). Investigamos a influência dos parâmetros de controle (pausa e setpoint) na criação dos padrões. A influência de fatores como o formato e desgaste da sonda, a reprodutibilidade do processo e outros efeitos instrumentais foram concomitantemente analisados. Verificamos que o processo de aragem dinâmica tem um melhor desempenho durante processos de SPL, pois os parâmetros de controle podem ser modificados de maneira simplificada. Além disso, o emprego deste método evita problemas de torção da haste que produzem irregularidades nos padrões. Outro fator verificado foi que o diâmetro das bordas pode ser diminuído com a utilização de filmes mais finos (menores que 10nm). A aplicação dos padrões formados em processos de nanolitografia, como a transferência de padrões para outros substratos foi demonstrada por deposição física de vapor e ataques químicos. / In this work we study the process of surfaces patterning based on an atomic force microscope. The mechanical indentation process was performed using two techniques: dynamic plowing and static plowing. These techniques have been applied to induce deformation in different materials (polymers and metals). We also proceed with the study of the controlling parameters (pause and setpoint) in the creation of the patterns. The influence of factors such as tip effects, tip degradation and structures replication had also been analyzed and the scanner effect verified. The Dynamic Plowing achieved best results against the static plowing because the controlling parameters can be easily controlled. The using of Dynamic Plowing avoids bending of the cantilever which may lead to pattern irregularities. Another study verified that thin films with width below 10nm are better suitable for SPL application, since the borders can be minimized. The application of these techniques in nanolithography processes such as pattern transfer was executed by physical vapor deposition and wet-chemical etching.
122

Estabilidade de nanopartículas em sílica : efeitos térmicos e de irradiação com elétrons e íons energéticos

Luce, Flavia Piegas January 2012 (has links)
Por apresentarem uma alta razão de área de interface por volume, sistemas de nanopartículas são termodinamicamente instáveis e podem perder suas vantagens funcionais em função de modificações estruturais induzidas por variações de parâmetros intensivos do ambiente de aplicação. O presente trabalho trata do estudo da estabilidade estrutural de sistemas densos de nanopartículas de Pb embebidos em substratos de sílica frente às variações de temperatura e a exposição à irradiação com elétrons e íons energéticos. Substratos de SiO2/Si foram implantados com íons de Pb e submetidos à diferentes condições de tratamento térmico e irradiações com elétrons e íons pesados. Evoluções microestruturais foram acompanhadas através de medidas de espectrometria de retroespalhamento Rutherford e por análises de microscopia eletrônica de transmissão em modo convencional e in-situ, acompanhando em tempo real as mudanças introduzidas pelo aquecimento e bombardeamentos iônico e eletrônico. A síntese das amostras segue uma rota alternativa, desenvolvida no próprio grupo de pesquisa, que resulta na formação de aglomerados atômicos com diâmetros de 1 nm ou inferiores, os quais são altamente estáveis e só se dissociam em temperaturas de ≈ 600 °C acima da temperatura de fusão do Pb massivo. Em contraste com a literatura, apresenta-se um modelo que explica a alta estabilidade térmica desses aglomerados como consequência da formação de interfaces com menor energia livre, e não somente em função do tipo de arranjo estrutural ou do fortalecimento das ligações químicas entre os átomos do aglomerado. Além disso, os resultados mostram que o sistema de aglomerados evolui de maneira peculiar quando submetido simultaneamente a recozimentos e a irradiações em alta temperatura. Em particular, demonstra-se que a irradiação com elétrons do próprio feixe do microscópio, que ocorre durante observações com recozimento in-situ, afeta tanto os processos de difusão atômica como os de nucleação e crescimento de nanopartículas. Os experimentos in-situ possibilitam observar o comportamento de partículas individuais com tamanhos da ordem de 3 a 15 nm de diâmetro a temperaturas entre 30 e 1100 °C. As medidas registradas em vídeo mostram que, para temperaturas acima de 400 °C, partículas com diâmetro maior que 3 nm estão na fase líquida e migram pela matriz sólida apresentando um movimento do tipo Browniano. Estes resultados são discutidos considerando que a migração das partículas é causada por interações inelásticas, onde os elétrons do feixe do microscópio rompem as ligações atômicas e diminuem a barreira de energia de migração dos átomos da matriz localizados na interface com a partícula. Nos experimentos envolvendo irradiação com íons pesados em amostras contendo partículas de Pb relativamente grandes (diâmetros de ≈ 15 nm), demonstra-se que os efeitos da irradiação são: alongar as partículas na direção do feixe de íons e promover sua decomposição parcial formando partículas "satélites". Estes fenômenos são discutidos em termos de modelos da literatura. Entretanto, o resultado mais surpreendente é o de que as partículas satélites são muito estáveis, não se decompondo mesmo após recozimentos a 1100 °C. Este fenômeno é discutido utilizando-se os mesmos argumentos do modelo que explica a estabilidade dos aglomerados. Em termos gerais, esta tese apresenta e discute novos fenômenos relacionados com a estabilidade de sistemas de nanopartículas frente a tratamentos térmicos e à irradiação por elétrons e íons. Considerando o sistema de partículas de Pb em substrato de sílica como um caso modelo, os presentes resultados introduzem novos conceitos sobre o comportamento individual e coletivo de partículas, questionando suas potenciais aplicações em ambientes agressivos frente a irradiações com elétrons e íons pesados, tipicamente encontrados no espaço próximo da órbita da Terra bem como em reatores nucleares. / Because of their high interface area to volume ratio, nanoparticle systems are intrinsically in a non-thermodynamic-equilibrium state and when submitted to harsh environments these nanomectric structures may loose their functional advantages. In this work we investigate the microstructural changes of Pb nanoparticles embedded in silica films. The modifications were induced by different conditions of thermal annealing and irradiations with electrons and heavy ions. Nanoparticles were formed via Ion Beam Synthesis, combining Pb ion implantation and different steps of thermal annealing and irradiations. Microstructural evolutions were characterized by Rutherford backscattering spectrometry and transmission electron microscopy in conventional mode as well as in-situ, monitoring in real time the changes caused by thermal annealing and irradiation experiments performed inside the microscope. Thermally stable nanoparticles were obtained through an original experimental route develop by our research group. It consists of a long time low temperature annealing which results in the formation of small structures with ≈ 1 nm in diameter that dissociate at temperatures ≈ 600 °C higher than the melting temperature of the metallic bulk Pb. In contrast to what is presented in the literature, our results are discussed considering that the thermal stability of the nanoparticles is due to the formation of Pb clusters with low interface free energy with the SiO2 matrix. Moreover, it was also demonstrated that the thermally stable nanoparticle system evolves in a peculiar way when submitted simultaneously to high temperature annealing and electron irradiations. In particular, the high temperature thermal treatment performed inside the microscope during the observations affects atomic diffusion and also nanoparticle nucleation and growth processes. In-situ experiments allow a clear observation and analysis of the behavior of individual nanoparticles ranging from 3 to 15 nm in diameter when submitted to annealings between 30 °C and 1100 °C. Videos recorded during the in-situ thermal treatment reveal that nanoparticles larger than 3 nm in diameter migrate trough the silica film, presenting Brownian-like motion. The results are discussed considering that migration is caused by inelastic interaction, where the electrons from the microscope break atomic bonds reducing the migration energy barrier of the matrix atoms located at the particle surface. Concerning heavy ion irradiation of large Pb particles (≈ 15 nm in diameter), the main results demonstrate that the bombardment introduce a shape change in these particles, elongating them in the direction parallel to the ion beam incidence. In addition, the irradiation promotes the partial dissolution of the nanoparticles and the formation of nanomectric structures surrounding the central particle. These nanoparticles, named satellites, are thermally stable, maintaining its microstructural characteristics even when annealed at temperatures as high as 1100 °C. To sum up, this thesis presents and discusses new phenomena related to thermal stability of nanoparticles under high temperature and irradiation with electrons and heavy ions. The system formed by Pb nanoparticles embedded in sil ica film can be considered as a model case for the study of the individual and collective particle behavior submitted to harsh environments, similar to those presented in the space and in nuclear reactors.
123

Avaliação tomográfica da cobertura óssea em diferentes tipos de padrão esquelético e inclinação dos incisivos

Lessa, Anne Maria Guimarães January 2016 (has links)
Submitted by Hiolanda Rêgo (hiolandarego@gmail.com) on 2016-09-08T13:09:54Z No. of bitstreams: 1 Dissertação_ODONTO_ Anne Maria Guimarães Glessa.pdf: 2049486 bytes, checksum: 3cfa2e4b181a698e0a21b95a118212db (MD5) / Approved for entry into archive by Uillis de Assis Santos (uillis.assis@ufba.br) on 2016-10-05T11:36:01Z (GMT) No. of bitstreams: 1 Dissertação_ODONTO_ Anne Maria Guimarães Glessa.pdf: 2049486 bytes, checksum: 3cfa2e4b181a698e0a21b95a118212db (MD5) / Made available in DSpace on 2016-10-05T11:36:01Z (GMT). No. of bitstreams: 1 Dissertação_ODONTO_ Anne Maria Guimarães Glessa.pdf: 2049486 bytes, checksum: 3cfa2e4b181a698e0a21b95a118212db (MD5) / CAPES / O estudo da estrutura de suporte dentário apresenta importante papel no planejamento odontológico dos indivíduos, com destaque para a cobertura óssea (CO). É possível que o padrão esquelético e a inclinação dos incisivos estejam relacionados com esta CO e tem sido demonstrado que a avaliação desta pela Tomografia Computadorizada de Feixe Cônico (TCFC) representa uma ferramenta auxiliar no diagnóstico. O objetivo desse trabalho foi correlacionar o diagnóstico de CO com o padrão esquelético e a inclinação dos incisivos. Para tanto, foi utilizada uma amostra de conveniência com exames tomográficos selecionados de indivíduos a ser submetidos a tratamento ortodôntico, e foram aplicados os critérios de exclusão para obtenção da amostra final. O padrão esquelético foi determinado através do ângulo ANB e pela análise de Wits, e a inclinação dos incisivos, através das medidas 1.NA, 1-NA, 1.NB, 1-NB e ângulo interincisal (1:1). Dois avaliadores treinados analisaram e classificaram a CO em 15 indivíduos de cada um dos três padrões esqueléticos, em cada terço dos dentes anteriores, como crítica, delgada, regular ou espessa. Houve concordância entre a condição dos indivíduos classificados pelo ANB e Wits, visto que ambos apresentam melhor condição de CO no padrão esquelético de classe II e menor CO nas classes I e III, com condição menos grave na classe I avaliada pelo Wits. No universo desta amostra percebeu-se maior proporção de defeitos ósseos nos terços médios, equivalendo a 411 (76%) terços médios concordantes entre os avaliadores do total de 540 avaliados, embora não estatisticamente significante (p<0,05), pela distribuição uniforme. O terço apical apresentou melhores condições e a maior representatividade de CO regular e espessa. A CO crítica foi mais observada no terço cervical dos incisivos centrais inferiores (ICI) e incisivos laterais inferiores (ILI); no médio do canino superior (CS) e ILI; e no apical em ICI e canino inferior (CI). Os incisivos centrais superiores (ICS) e incisivos laterais superiores (ILS) apresentaram menor CO quando estavam mais verticalizados, repetindo-se principalmente nos terços médios e apicais com a maior retrusão dos ICS. A maior vestibularização dos incisivos superiores estava associada à menor CO nos terços cervicais dos ICI e ILI. No ICI, observou-se menor CO no cervical quando os incisivos inferiores estavam mais verticalizados e retraídos. Sendo assim, maior cuidado deve ser dado na avaliação dos incisivos inferiores, uma vez que estes apresentaram a pior condição de CO e essa situação é ainda mais agravada em dentes mais verticalizados, tendo o padrão esquelético de classe III a maior proporção de CO crítica dentre as demais.
124

Efeito da expansão rápida da maxila sobre o osso alveolar vestibular: estudo por TCFC

Barbosa, Marcelo de Castelucci e January 2016 (has links)
Submitted by Programa de Pós-Graduação em Odontologia Saúde (mestrodo@ufba.br) on 2016-11-23T13:37:35Z No. of bitstreams: 1 TESE DOUTORADO MARCELO DE CASTELLUCCI.pdf: 7136766 bytes, checksum: ab6440db29f5aab10942601aa6ca4e09 (MD5) / Approved for entry into archive by Uillis de Assis Santos (uillis.assis@ufba.br) on 2016-11-23T13:43:59Z (GMT) No. of bitstreams: 1 TESE DOUTORADO MARCELO DE CASTELLUCCI.pdf: 7136766 bytes, checksum: ab6440db29f5aab10942601aa6ca4e09 (MD5) / Made available in DSpace on 2016-11-23T13:44:00Z (GMT). No. of bitstreams: 1 TESE DOUTORADO MARCELO DE CASTELLUCCI.pdf: 7136766 bytes, checksum: ab6440db29f5aab10942601aa6ca4e09 (MD5) / Este estudo experimental tem o objetivo de avaliar, através de tomografia computadorizada de feixe cônico, alterações no osso alveolar vestibular e na inclinação dos primeiros molares superiores permanentes, após expansão rápida da maxila. Foram utilizadas 40 imagens, de 20 pacientes, com idades variando de 10 a 14 anos, sendo 15 do gênero masculino e 5 do feminino, realizadas antes e após a expansão rápida da maxila, feita com o aparelho disjuntor tipo Haas. Utilizando o programa Dolphin Imaging versão 11.0 Premium e a partir da reconstrução multiplanar, foi medida a espessura do osso vestibular às raízes dos primeiros molares, nos terços apical, médio e cervical, além da distância entre a junção amelocementária e a crista óssea alveolar. Foram medidos, também, os ângulos formados entre o longo eixo dos primeiros molares superiores e o palato. Para a análise das diferenças entre as medidas dos dois tempos, utilizou-se o teste t de Student. Para testar a associação entre as variáveis, utilizou-se a análise de correlação de Pearson, todos com nível de significância de 95%. Observou-se um aumento significativo no ângulo formado entre os primeiros molares superiores e o palato duro, assim como nas medidas de largura do palato. Não houve alterações significativas de espessura óssea vestibular aos primeiros molares, nas porções apical e média das raízes. No entanto, houve uma diminuição dessa espessura na porção cervical das raízes desses dentes. Não foram encontradas alterações na distância entre a junção amelocementária e a crista alveolar. Não houve relação das alterações na espessura da cortical óssea alveolar vestibular com a mudança de inclinação vestibulolingual desses dentes, nem com a quantidade de expansão realizada. Contudo, foi encontrada uma correlação positiva entre a diminuição de espessura da cortical óssea vestibular, na porção cervical, e a espessura inicial dessa medida. Dentre os parâmetros avaliados, a única variável que apresentou diminuição foi a espessura óssea vestibular às raízes dos primeiros molares, na porção cervical. / This longitudinal clinical study used cone beam computed tomography to evaluate changes in alveolar bone and inclination of maxillary first molars after rapid maxillary expansion. Cone beam computed tomography images of 20 patients (15 male and 5 female), aged from 10 to 14 years old, were used, captured before and after expansion with Haas type appliance. In multiplanar reconstructions made with Dolphin Imaging 11.0 Premium software, vestibular bone thickness was measured at apical, middle and cervical thirds of these roots, in addition to distance between the amelocemental junction and alveolar bone crest. Palatal width and the angles formed between the long axis of the maxillary first molars and palate were also measured. There were significant increase in the angle formed between the long axis of the maxillary first molars and palate and also in palatal width. There were no significant changes in vestibular bone thickness in the apical and middle portions of the roots. However, there was decrease in this thickness in the cervical portion. No changes were found in the distance between the amelocemental junction and alveolar crest. There was no relation between the changes in thickness of the vestibular alveolar bone and change in inclination of these teeth, or quantity of expansion performed. However, positive correlation was found between the reduction in vestibular cortical bone thickness in the cervical portion and the initial thickness of this measurement. Among the periodontal parameters evaluated, the only variable that presented any reduction was the vestibular bone thickness in the cervical portion of the first molar roots.
125

Acurácia de medidas cefalométricas em diferentes exames de imagem

Barreto, Mônica Sena January 2016 (has links)
Submitted by Programa de Pós-Graduação em Odontologia Saúde (mestrodo@ufba.br) on 2016-11-29T14:22:11Z No. of bitstreams: 1 Acurácia de medidas cefalométricas em diferentes exames de imagem - Dissertação - Mônica Sena Barreto.pdf: 2231259 bytes, checksum: f97506ccbf756863f6dbcae01ec4d853 (MD5) / Approved for entry into archive by Delba Rosa (delba@ufba.br) on 2016-12-19T15:11:11Z (GMT) No. of bitstreams: 1 Acurácia de medidas cefalométricas em diferentes exames de imagem - Dissertação - Mônica Sena Barreto.pdf: 2231259 bytes, checksum: f97506ccbf756863f6dbcae01ec4d853 (MD5) / Made available in DSpace on 2016-12-19T15:11:11Z (GMT). No. of bitstreams: 1 Acurácia de medidas cefalométricas em diferentes exames de imagem - Dissertação - Mônica Sena Barreto.pdf: 2231259 bytes, checksum: f97506ccbf756863f6dbcae01ec4d853 (MD5) / CAPES / O exame de tomografia computadorizada (TC) trouxe para a cefalometria novos recursos, inclusive a possibilidade de avaliação tridimensional. Dentre os equipamentos de TC, destaca-se o sistema de aquisição de imagem denominado de TC de feixe cônico (TCFC) ou cone beam, especialmente dedicado ao estudo tomográfico da face. Diante da sua crescente utilização em Ortodontia, o objetivo deste estudo foi avaliar a acurácia de medidas lineares realizadas em reconstruções multiplanares (RMP) e reconstruções sagitais (RS) da hemi-face esquerda obtidas a partir de TCFC pelo software Dolphin Imaging 3D®, comparando-as com as mesmas medidas realizadas em radiografias cefalométricas de perfil. Para isto, dez crânios secos foram submetidos a telerradiografias em norma lateral e a TCFC (com voxels de 0,25 mm, 0,3 mm e 0,4 mm). As radiografias e os dados da TCFC foram importados para um software, no qual essas últimas foram processadas, seguindo os parâmetros default do programa, para obtenção de RMP e RS da hemi-face esquerda. Em cada imagem foram aferidas distâncias lineares, utilizando-se as réguas eletrônicas do programa. Medidas realizadas nos crânios secos com auxílio de um paquímetro digital foram consideradas o padrão-ouro. As medidas foram realizadas por dois avaliadores, duas vezes, e os dados foram comparados e submetidos à análise estatística. Os resultados mostraram não haver diferenças significativas nas medidas realizadas nas diferentes modalidades de imagem e nos crânios secos. Em relação aos erros absoluto e relativo, observou-se que houve diferença significante entre as medidas realizadas na telerradiografias em norma lateral e aquelas das RS, nos três tamanhos de voxel. A maior média de erro foi observada na telerradiografia em normal lateral, seguida da RMP e da RS. Do exposto pode-se concluir que as medidas cefalométricas nas imagens derivadas da reconstrução da TCFC, independentemente do tamanho do voxel, são reproduzíveis e válidas, se comparadas com as medidas obtidas na telerradiografia em norma lateral. / Computed tomography (CT) brought to cephalometrics new features, including the possibility of three-dimensional evaluation. Among the CT equipment, there is the image acquisition system called cone beam CT (CBCT), especially dedicated to the CT scan of the face. The aim of this study was to evaluate the accuracy of linear measurements performed in multiplanar reconstructions (RMP) and sagittal reconstructions (RS) from the left hemi-face obtained from the CBCT software Dolphin Imaging 3D®, comparing with the same measurements in cephalometric radiographs. For this, ten dry skulls underwent lateral cephalometric radiographs and CBCT (with voxels of 0.25 mm, 0.3 mm and 0.4 mm). Radiographs and data from CBCT were imported into software, in which these latter were processed following the default parameters, to obtain RMP and RS of the hemi-face left. In each image were measured linear distances, using the electronic program rules. Measurements in dry skulls with the aid of a digital caliper were considered the gold standard. Two observers, performed the measurements twice, and the data were compared and analyzed statistically. The results showed no significant differences in measurements performed in different imaging modalities and dry skulls. Regarding the absolute and relative errors, we observed a significant difference between the measurements in lateral cephalometric radiographs and those of the RS, at the three-voxel sizes. The highest average error was observed in the lateral radiograph at normal, then the RMP and the RS. From the above, it can conclude that the cephalometric measurements on the images derived from the CBCT reconstruction, regardless of the voxel size, are reproducible and valid, when compared with the measurements obtained in radiography in lateral view.
126

Acurácia de medidas cefalométricas em diferentes exames de imagem

Barreto, Mônica Sena January 2016 (has links)
Submitted by Hiolanda Rêgo (hiolandarego@gmail.com) on 2017-02-14T12:35:56Z No. of bitstreams: 1 Dissertação_ODONTO_ Mônica Sena Barreto.pdf: 2231259 bytes, checksum: f97506ccbf756863f6dbcae01ec4d853 (MD5) / Approved for entry into archive by Delba Rosa (delba@ufba.br) on 2017-06-29T12:30:06Z (GMT) No. of bitstreams: 1 Dissertação_ODONTO_ Mônica Sena Barreto.pdf: 2231259 bytes, checksum: f97506ccbf756863f6dbcae01ec4d853 (MD5) / Made available in DSpace on 2017-06-29T12:30:06Z (GMT). No. of bitstreams: 1 Dissertação_ODONTO_ Mônica Sena Barreto.pdf: 2231259 bytes, checksum: f97506ccbf756863f6dbcae01ec4d853 (MD5) / CAPES / O exame de tomografia computadorizada (TC) trouxe para a cefalometria novos recursos, inclusive a possibilidade de avaliação tridimensional. Dentre os equipamentos de TC, destaca-se o sistema de aquisição de imagem denominado de TC de feixe cônico (TCFC) ou cone beam, especialmente dedicado ao estudo tomográfico da face. Diante da sua crescente utilização em Ortodontia, o objetivo deste estudo foi avaliar a acurácia de medidas lineares realizadas em reconstruções multiplanares (RMP) e reconstruções sagitais (RS) da hemi-face esquerda obtidas a partir de TCFC pelo software Dolphin Imaging 3D®, comparando-as com as mesmas medidas realizadas em radiografias cefalométricas de perfil. Para isto, dez crânios secos foram submetidos a telerradiografias em norma lateral e a TCFC (com voxels de 0,25 mm, 0,3 mm e 0,4 mm). As radiografias e os dados da TCFC foram importados para um software, no qual essas últimas foram processadas, seguindo os parâmetros default do programa, para obtenção de RMP e RS da hemi-face esquerda. Em cada imagem foram aferidas distâncias lineares, utilizando-se as réguas eletrônicas do programa. Medidas realizadas nos crânios secos com auxílio de um paquímetro digital foram consideradas o padrão-ouro. As medidas foram realizadas por dois avaliadores, duas vezes, e os dados foram comparados e submetidos à análise estatística. Os resultados mostraram não haver diferenças significativas nas medidas realizadas nas diferentes modalidades de imagem e nos crânios secos. Em relação aos erros absoluto e relativo, observou-se que houve diferença significante entre as medidas realizadas na telerradiografias em norma lateral e aquelas das RS, nos três tamanhos de voxel. A maior média de erro foi observada na telerradiografia em normal lateral, seguida da RMP e da RS. Do exposto pode-se concluir que as medidas cefalométricas nas imagens derivadas da reconstrução da TCFC, independentemente do tamanho do voxel, são reproduzíveis e válidas, se comparadas com as medidas obtidas na telerradiografia em norma lateral.
127

Efeito da expansão rápida da maxila sobre o osso alveolar vestibular: Estudo por TCFC

Barbosa, Marcelo de Castellucci e January 2016 (has links)
Submitted by Hiolanda Rêgo (hiolandarego@gmail.com) on 2017-03-14T13:03:54Z No. of bitstreams: 1 Tese_ODONTO_Marcelo de Castellucci e Barbosa.pdf: 7136766 bytes, checksum: ab6440db29f5aab10942601aa6ca4e09 (MD5) / Approved for entry into archive by Delba Rosa (delba@ufba.br) on 2017-03-23T13:45:37Z (GMT) No. of bitstreams: 1 Tese_ODONTO_Marcelo de Castellucci e Barbosa.pdf: 7136766 bytes, checksum: ab6440db29f5aab10942601aa6ca4e09 (MD5) / Made available in DSpace on 2017-03-23T13:45:37Z (GMT). No. of bitstreams: 1 Tese_ODONTO_Marcelo de Castellucci e Barbosa.pdf: 7136766 bytes, checksum: ab6440db29f5aab10942601aa6ca4e09 (MD5) / Este estudo experimental tem o objetivo de avaliar, através de tomografia computadorizada de feixe cônico, alterações no osso alveolar vestibular e na inclinação dos primeiros molares superiores permanentes, após expansão rápida da maxila. Foram utilizadas 40 imagens, de 20 pacientes, com idades variando de 10 a 14 anos, sendo 15 do gênero masculino e 5 do feminino, realizadas antes e após a expansão rápida da maxila, feita com o aparelho disjuntor tipo Haas. Utilizando o programa Dolphin Imaging versão 11.0 Premium e a partir da reconstrução multiplanar, foi medida a espessura do osso vestibular às raízes dos primeiros molares, nos terços apical, médio e cervical, além da distância entre a junção amelocementária e a crista óssea alveolar. Foram medidos, também, os ângulos formados entre o longo eixo dos primeiros molares superiores e o palato. Para a análise das diferenças entre as medidas dos dois tempos, utilizou-se o teste t de Student. Para testar a associação entre as variáveis, utilizou-se a análise de correlação de Pearson, todos com nível de significância de 95%. Observou-se um aumento significativo no ângulo formado entre os primeiros molares superiores e o palato duro, assim como nas medidas de largura do palato. Não houve alterações significativas de espessura óssea vestibular aos primeiros molares, nas porções apical e média das raízes. No entanto, houve uma diminuição dessa espessura na porção cervical das raízes desses dentes. Não foram encontradas alterações na distância entre a junção amelocementária e a crista alveolar. Não houve relação das alterações na espessura da cortical óssea alveolar vestibular com a mudança de inclinação vestibulolingual desses dentes, nem com a quantidade de expansão realizada. Contudo, foi encontrada uma correlação positiva entre a diminuição de espessura da cortical óssea vestibular, na porção cervical, e a espessura inicial dessa medida. Dentre os parâmetros avaliados, a única variável que apresentou diminuição foi a espessura óssea vestibular às raízes dos primeiros molares, na porção cervical.
128

Avaliação das dimensões da orofaringe de indivíduos portadores de fissuras labiopalatinas por meio de tomografia computadorizada de feixe cônico

Barbosa, Inêssa da Silva January 2014 (has links)
Submitted by Hiolanda Rêgo (hiolandarego@gmail.com) on 2017-04-04T13:43:27Z No. of bitstreams: 1 Dissertação_ODONTO_Inêssa da Silva Barbosa.pdf: 15513737 bytes, checksum: 307c3b4ad0d58b0e4c14a6bea612683c (MD5) / Approved for entry into archive by Delba Rosa (delba@ufba.br) on 2017-07-03T15:44:56Z (GMT) No. of bitstreams: 1 Dissertação_ODONTO_Inêssa da Silva Barbosa.pdf: 15513737 bytes, checksum: 307c3b4ad0d58b0e4c14a6bea612683c (MD5) / Made available in DSpace on 2017-07-03T15:44:56Z (GMT). No. of bitstreams: 1 Dissertação_ODONTO_Inêssa da Silva Barbosa.pdf: 15513737 bytes, checksum: 307c3b4ad0d58b0e4c14a6bea612683c (MD5) / FAPESB / A compreensão das características morfológicas do espaço aéreo faríngeo de indivíduos portadores de fissuras labiopalatais (FLPs) é de grande importância, uma vez que procedimentos cirúrgicos adotados para a sua correção, especialmente a palatoplastia, tem como potencial complicação manifestações agudas da síndrome da apneia e hipopneia obstrutiva do sono. Assim, o objetivo desse estudo foi realizar uma avaliação tridimensional da orofaringe de pacientes fissurados cirurgicamente tratados, por meio de tomografia computadorizada de feixe cônico (TCFC), procurando investigar uma possível relação entre a presença de fissuras, o padrão esquelético e as dimensões da orofaringe. Para isso, foram selecionados exames por TCFC de 23 pacientes portadores de FLPs e de 48 pacientes não portadores de qualquer malformação facial, todos já tendo ultrapassado o surto de crescimento puberal. As imagens tomográficas foram analisadas utilizando o programa Dolphin Imaging® versão 11.5 Premium (Dolphin Imaging & Management Solutions, Chatsworth, California, EUA), tendo sido mensurados o volume total da orofaringe, a área sagital, a mínima secção transversal e as menores distâncias ântero-posterior (AP) e transversa (TR) dos portadores e não portadores de FLPs. Adicionalmente, essas medidas foram comparadas em relação ao padrão esquelético, independente da presença da fissura, de acordo com o valor do ângulo ANB. Os resultados mostraram não haver diferenças estatisticamente significativas em quaisquer das medidas avaliadas (p = 0,961; p = 0,114; p = 0,672; p = 0,363; p = 0,288) quando comparados fissurados e não fissurados, porém apresentaram uma diferença estatisticamente significativa quando comparados os três padrões esqueléticos (p = 0,000; p = 0,001; p = 0,000; p = 0,006; p = 0,004), tendo o padrão esquelético de classe II apresentado medidas menores que as classes I e III. Conclusão: as dimensões da orofaringe de pacientes com o crescimento completo não são alteradas pela FLP cirurgicamente tratada; o padrão esquelético de classe II tem uma relação direta com a redução das dimensões orofaringe, independente da presença da FLP; as dimensões da orofaringe não diferem significativamente entre pacientes classes I e III.
129

Acurácia da imagem de diferentes tomógrafos de feixe cônico na avaliação da cobertura óssea em dentes anteriores

Dantas, Luciana Loyola January 2016 (has links)
Submitted by Hiolanda Rêgo (hiolandarego@gmail.com) on 2017-04-11T13:23:53Z No. of bitstreams: 1 Dissertação_ODONTO_Luciana Loyola Dantas.pdf: 1433157 bytes, checksum: f209b858f15d60f72bfd4d118d2aa377 (MD5) / Approved for entry into archive by Delba Rosa (delba@ufba.br) on 2017-07-03T15:35:27Z (GMT) No. of bitstreams: 1 Dissertação_ODONTO_Luciana Loyola Dantas.pdf: 1433157 bytes, checksum: f209b858f15d60f72bfd4d118d2aa377 (MD5) / Made available in DSpace on 2017-07-03T15:35:28Z (GMT). No. of bitstreams: 1 Dissertação_ODONTO_Luciana Loyola Dantas.pdf: 1433157 bytes, checksum: f209b858f15d60f72bfd4d118d2aa377 (MD5) / CNPq / O presente estudo teve como objetivo determinar a acurácia diagnóstica da imagem obtida a partir de diferentes tomógrafos de feixe cônico na avaliação da presença ou ausência de cobertura óssea em dentes anteriores. Foram adquiridas imagens de TCFC da região de maxila e mandíbula de um crânio seco em seis diferentes tomógrafos: Accuitomo (J. Morita, Kyoto, Japão); CS 9000 3D (Carestream Dental, Trophy, Marne La Vallée, França); CS 9300 (Carestream Dental, Trophy, Marne La Vallée, França); Eagle 3D (Dabi Atlante, Oklahoma, EUA); i-CAT Classic (Imaging Sciences International, Hatfield, Pensilvânia, EUA) e Orthophos XG 3D (Sirona Dental System, Charlote, EUA). Dois radiologistas avaliaram as imagens e um ortodontista avaliou o crânio seco. Os resultados demonstraram alta acurácia diagnóstica na avaliação da cobertura óssea nos tomógrafos estudados, com uma superioridade do CS 9300, que além de alta acurácia, apresentou alta sensibilidade e especificidade com um menor tempo de escaneamento e menor exposição do paciente à radiação ionizante.
130

Acurácia da imagem tomográfica de feixe cônico na avaliação da ausência de cobertura óssea em dentes anteriores

Ferreira, Paula Paes January 2014 (has links)
Submitted by Hiolanda Rêgo (hiolandarego@gmail.com) on 2017-07-27T14:40:16Z No. of bitstreams: 1 Dissertação_ODONTO_Paula Paes Ferreira.pdf: 3790512 bytes, checksum: 9e36ae4b4df28d2680d296d98fff6de4 (MD5) / Approved for entry into archive by Delba Rosa (delba@ufba.br) on 2017-07-27T14:51:24Z (GMT) No. of bitstreams: 1 Dissertação_ODONTO_Paula Paes Ferreira.pdf: 3790512 bytes, checksum: 9e36ae4b4df28d2680d296d98fff6de4 (MD5) / Made available in DSpace on 2017-07-27T14:51:24Z (GMT). No. of bitstreams: 1 Dissertação_ODONTO_Paula Paes Ferreira.pdf: 3790512 bytes, checksum: 9e36ae4b4df28d2680d296d98fff6de4 (MD5) / FAPESB / O diagnóstico da ausência de cobertura óssea (CO) na região vestibular dos dentes anteriores é fundamental para o planejamento e tratamento em diversas áreas da Odontologia. Porém, a avaliação de diminutos defeitos ósseos representa um desafio à ciência, que através de inúmeros exames por imagem busca à acurada avaliação frente a estas situações. Com o advento e consolidação da Tomografia Computadorizada de Feixe Cônico (TCFC) como excelente método para quantificar osso com a possibilidade de doses de radiação reduzidas, este trabalho tem como objetivo avaliar o diagnóstico da ausência de CO, em dentes anteriores, através de imagens por TCFC. Para tanto, cinco crânios secos foram selecionados e os defeitos ósseos identificados através da análise visual direta dos dentes anteriores. TCFC parciais da maxila e da mandíbula de cada crânio foram realizadas e as imagens analisadas por dois examinadores, que identificaram a presença ou não de cobertura óssea em cada região. Nas reconstruções axiais, 93,65% das ausências de cobertura óssea foram diagnosticadas pelo avaliador A e 92,06% pelo avaliador B, já nas imagens sagitais, 65,01% desses defeitos foram visualizados pelo avaliador A e 82,54% pelo avaliador B, sendo que ao juntar o diagnóstico das duas reconstruções, 95,24% de todos os defeitos ósseos presentes nos crânios foram diagnosticados corretamente por ambos avaliadores. Sendo assim, a TCFC apresentou uma acurácia de 98,33% e 88,33%, uma sensibilidade de 100% e 95,65% e uma especificidade de 97,3% e 83,78% para os avaliadores A e B respectivamente, demonstrando ser um exame excelente e, portanto, válido para o diagnóstico da ausência de CO na cortical vestibular dos dentes anteriores.

Page generated in 0.068 seconds