• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 488
  • 7
  • 6
  • 6
  • 6
  • 6
  • 4
  • 4
  • 4
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 510
  • 370
  • 362
  • 357
  • 353
  • 292
  • 287
  • 273
  • 122
  • 68
  • 58
  • 53
  • 53
  • 52
  • 45
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
161

Estudo de calcificações em tecidos moles em exames de tomografia computadorizada de feixe cônico utilizando diferentes softwares

Bruna Stuchi Centurion Pagin 22 June 2015 (has links)
O uso crescente da Tomografia Computadorizada de Feixe Cônico (TCFC) na área odontológica tem permitido o aumento dos achados incidentais em exames que são realizados por outros fins. Dentre essas uma, das mais comuns e com impacto na vida dos pacientes é o ateroma calcificado das artérias carótidas (ACAC), e no seu diagnóstico diferencial existem as ossificações das cartilagens da laringe. Para correta identificação dessas calcificações são necessários conhecimentos acerca da localização anatômica, distribuição e sua morfologia, sendo que a TCFC fornece uma localização tridimensional (3D) acurada. Entretanto existem diferentes softwares de pós-processamento de imagens disponíveis no mercado, e não há na literatura estudos sobre a capacidade desses softwares para a visualização dessas estruturas. Esse estudo tem o objetivo de identificar essas calcificações supracitadas, nos softwares de visualização de TCFC, i-Cat Vision® e Invivo5®, nas reconstruções multiplanares e 3D em dois grupos diferentes, sendo um grupo de exames de indivíduos com fissuras labiopalatinas (HRAC) (50 exames de TCFC) e outro sem fissuras labiopalatinas (FOB) (100 exames de TCFC). Foram avaliados 150 exames (112 do gênero feminino e 38 do gênero masculino) de TCFC por dois observadores devidamente treinados e calibrados. Para o grupo sem fissuras labiopalatinas foi encontrada diferença estatística significante entre a idade e a quantidade de calcificações encontradas. Considerando todas as calcificações, foram encontrados 104 indivíduos com alguma calcificação, representando 69,33% da amostra, sendo que o grupo HRAC apresentou 88% e o grupo FOB 59%. Foi possível demonstrar diferença estatística significante ao se comparar a quantidade de calcificações entre os grupos avaliados. Foi assumido nesse trabalho que as reconstruções separadamente do programa Invivo5® seria a padrão- ouro, nesse momento o programa i-Cat Vision® foi considerado mais específico do que sensível. Foram identificados muito falsos positivos no programa i-Cat Vision® e menores resultados para falso-negativos. Esse trabalho não tem o propósito de identificar os ACAC nos exames de TCFC, mas incentivar e demonstrar que é possível visualizar tais calcificações e diferenciá-las umas das outra, lembrando-se da responsabilidade do dentista em prevenir um problema futuro ao paciente que pode levar a quadros de morbidade e mortalidade. / The widespread use of CBCT in Dentistry leads to an increasing of incidental findings regarding exams for different purposes. The most common incidental finding that impacts the patients quality of life is the carotid artery calcifications as well as the ossification of laryngeal cartilage which is the most common differential diagnosis for aterosclerosis. To identify this calcifications/ossification correctly it is necessary to know about its anatomic localization, distribution and morphology once that CBCT images may evidence an accurate 3D location. Therefore many different manipulations imaging software for CBCT technology is available and there is no research in the literature about the capacity of this software to visualize these calcification/ossification structures. This study aimed to identify these calcifications/ossification, in two different visualization softwares: i-Cat Vision® and Invivo5®, both in Multiplanar Reconstruction (MPR) and 3D reconstruction, in two different groups, where one was constituted of cleft lip and palate (50 CBCT exams) patients and the other by patients without cleft lip and palate (100 CBCT exams). Two calibrated and trained observers evaluated 150 CBCT exams (112 were female and 38 male). There was significantly statistical difference when comparing age and calcifications quantity for no cleft lip and palate group. When considering all calcifications in both groups, 104 patients in 150 (total number) showed some calcification/ossification, representing 69,33%. The percentage of calcification/ossification in the cleft lip and palate group were 88% whereas the other one evidenced 59%. And due to this difference, there was significantly statistical difference between these groups. Besides, the Invivo5® software was considered the gold-standard (multiplanar reconstruction and 3D reconstruction) to identify the structures previously mentioned; then i-Cat Vision® software showed more specificity than sensitivity comparing the results with the Invivo5®. Many false positives were identified in i-Cat Vision® and only some false negatives, showing again the characteristics of these softwares. This work was not intended to identify carotid artery calcifications in CBCT exams, but in fact the real purpose was to demonstrate that it is possible to identify calcifications/ossifications and differentiate one of another. It is always important to remember about the dentistry knowledge and responsibility to prevent patient coming disease that may lead to morbidity and mortality situations.
162

Estudo de calcificações em tecidos moles em exames de tomografia computadorizada de feixe cônico e radiografia panorâmica digital / Differentiating soft tissue calcifications in CBCT and panoramic images

Bruna Stuchi Centurion 29 April 2011 (has links)
A maioria das calcificações em tecidos moles na região de cabeça e pescoço são achados radiográficos incidentais. Com o crescente uso da Tomografia Computadorizada de Feixe Cônico na Odontologia (TCFC) há um aumento do número desses achados, visto que o exame permite a visualização das estruturas em três dimensões. Esse estudo estabeleceu uma metodologia para identificar algumas dessas calcificações. Um observador calibrado analisou 100 exames de TCFC e as respectivas panorâmicas, quanto à presença de Ossificação do Complexo Estilo-Hióideo (OCEH), tonsilólitos e ateromas. Adicionalmente os processos estilóides foram mensurados. As correlações para as radiografias panorâmicas foram estatisticamente significante entre idade e comprimento do processo estilóide. As correlações para os exames de TCFC foram estatisticamente significantes entre idade e tonsilólitos, idade e o comprimento do processo estilóide e idade e ateromas. Houve diferença estatística significante (Wilcoxon p<0,05) entre os exames de TCFC e panorâmicas quanto à presença de tonsilólitos, presença de OCEH e para as mensurações dos processos estilóides. Foi detectada maior quantidade de calcificações em tecidos moles nos exames de TCFC. A identificação das calcificações em tecidos moles é importante no diagnóstico diferencial de muitas patologias incluindo os flebólitos. Portanto o profissional deve ficar atento a correta interpretação dessas estruturas, buscando evitar erros e omissões, para que possa oferecer ao paciente opção correta de tratamento se for necessário. / The most common soft tissue calcifications in head and neck region are incidental findings in radiographic images. The use of Cone Beam Computed Tomography in Dentistry, has increased these incidental findings mainly, because CBCT allows a third dimension view. The goal of this study was to differentiate the styloid chain ossification (SHCO), tonsilloliths and calcified atheromas. Based on a specific methodology, one calibrated observer analysed 100 panoramic and CBCT exams from the same patients regarding these alterations. Afterwards, the styloid process was measured at the same exams. The correlations tests for the panoramic exams were statistically significant between age and styloid process length. The correlations tests for CBCT exams were statistically significant between age and tonsilloliths, age and styloid process length and age and calcified atheromas. There was a difference statistically significant (Wilcoxon p<0.05) between CBCT and panoramic exams regarding: presence of tonsillolith, presence of SHCO and styloid process length. It was detected more quantity of soft tissues calcifications in CBCT exams. The identification of soft tissues calcifications is important for the differential diagnoses of many pathologies including phlebolits. Therefore the professional should be able to do a correct image interpretation in some cases in order to avoid mistakes and offer the patient a treatment if is necessary.
163

Aplicação do modo de nanolitografia de um microscópio de força atômica para a estruturação de superfícies

Carreira, Willian Hasenkamp January 2007 (has links)
Neste trabalho, estudamos o processo de nanoestruturação de superfícies por microscopia de força atômica. O processo de indução mecânica de deformações foi abordado sob o enfoque de duas técnicas: a aragem dinâmica e a aragem estática. Essas técnicas foram aplicadas para nanoestruturar diferentes materiais (polímeros e metais). Investigamos a influência dos parâmetros de controle (pausa e setpoint) na criação dos padrões. A influência de fatores como o formato e desgaste da sonda, a reprodutibilidade do processo e outros efeitos instrumentais foram concomitantemente analisados. Verificamos que o processo de aragem dinâmica tem um melhor desempenho durante processos de SPL, pois os parâmetros de controle podem ser modificados de maneira simplificada. Além disso, o emprego deste método evita problemas de torção da haste que produzem irregularidades nos padrões. Outro fator verificado foi que o diâmetro das bordas pode ser diminuído com a utilização de filmes mais finos (menores que 10nm). A aplicação dos padrões formados em processos de nanolitografia, como a transferência de padrões para outros substratos foi demonstrada por deposição física de vapor e ataques químicos. / In this work we study the process of surfaces patterning based on an atomic force microscope. The mechanical indentation process was performed using two techniques: dynamic plowing and static plowing. These techniques have been applied to induce deformation in different materials (polymers and metals). We also proceed with the study of the controlling parameters (pause and setpoint) in the creation of the patterns. The influence of factors such as tip effects, tip degradation and structures replication had also been analyzed and the scanner effect verified. The Dynamic Plowing achieved best results against the static plowing because the controlling parameters can be easily controlled. The using of Dynamic Plowing avoids bending of the cantilever which may lead to pattern irregularities. Another study verified that thin films with width below 10nm are better suitable for SPL application, since the borders can be minimized. The application of these techniques in nanolithography processes such as pattern transfer was executed by physical vapor deposition and wet-chemical etching.
164

Estabilidade de nanopartículas em sílica : efeitos térmicos e de irradiação com elétrons e íons energéticos

Luce, Flavia Piegas January 2012 (has links)
Por apresentarem uma alta razão de área de interface por volume, sistemas de nanopartículas são termodinamicamente instáveis e podem perder suas vantagens funcionais em função de modificações estruturais induzidas por variações de parâmetros intensivos do ambiente de aplicação. O presente trabalho trata do estudo da estabilidade estrutural de sistemas densos de nanopartículas de Pb embebidos em substratos de sílica frente às variações de temperatura e a exposição à irradiação com elétrons e íons energéticos. Substratos de SiO2/Si foram implantados com íons de Pb e submetidos à diferentes condições de tratamento térmico e irradiações com elétrons e íons pesados. Evoluções microestruturais foram acompanhadas através de medidas de espectrometria de retroespalhamento Rutherford e por análises de microscopia eletrônica de transmissão em modo convencional e in-situ, acompanhando em tempo real as mudanças introduzidas pelo aquecimento e bombardeamentos iônico e eletrônico. A síntese das amostras segue uma rota alternativa, desenvolvida no próprio grupo de pesquisa, que resulta na formação de aglomerados atômicos com diâmetros de 1 nm ou inferiores, os quais são altamente estáveis e só se dissociam em temperaturas de ≈ 600 °C acima da temperatura de fusão do Pb massivo. Em contraste com a literatura, apresenta-se um modelo que explica a alta estabilidade térmica desses aglomerados como consequência da formação de interfaces com menor energia livre, e não somente em função do tipo de arranjo estrutural ou do fortalecimento das ligações químicas entre os átomos do aglomerado. Além disso, os resultados mostram que o sistema de aglomerados evolui de maneira peculiar quando submetido simultaneamente a recozimentos e a irradiações em alta temperatura. Em particular, demonstra-se que a irradiação com elétrons do próprio feixe do microscópio, que ocorre durante observações com recozimento in-situ, afeta tanto os processos de difusão atômica como os de nucleação e crescimento de nanopartículas. Os experimentos in-situ possibilitam observar o comportamento de partículas individuais com tamanhos da ordem de 3 a 15 nm de diâmetro a temperaturas entre 30 e 1100 °C. As medidas registradas em vídeo mostram que, para temperaturas acima de 400 °C, partículas com diâmetro maior que 3 nm estão na fase líquida e migram pela matriz sólida apresentando um movimento do tipo Browniano. Estes resultados são discutidos considerando que a migração das partículas é causada por interações inelásticas, onde os elétrons do feixe do microscópio rompem as ligações atômicas e diminuem a barreira de energia de migração dos átomos da matriz localizados na interface com a partícula. Nos experimentos envolvendo irradiação com íons pesados em amostras contendo partículas de Pb relativamente grandes (diâmetros de ≈ 15 nm), demonstra-se que os efeitos da irradiação são: alongar as partículas na direção do feixe de íons e promover sua decomposição parcial formando partículas "satélites". Estes fenômenos são discutidos em termos de modelos da literatura. Entretanto, o resultado mais surpreendente é o de que as partículas satélites são muito estáveis, não se decompondo mesmo após recozimentos a 1100 °C. Este fenômeno é discutido utilizando-se os mesmos argumentos do modelo que explica a estabilidade dos aglomerados. Em termos gerais, esta tese apresenta e discute novos fenômenos relacionados com a estabilidade de sistemas de nanopartículas frente a tratamentos térmicos e à irradiação por elétrons e íons. Considerando o sistema de partículas de Pb em substrato de sílica como um caso modelo, os presentes resultados introduzem novos conceitos sobre o comportamento individual e coletivo de partículas, questionando suas potenciais aplicações em ambientes agressivos frente a irradiações com elétrons e íons pesados, tipicamente encontrados no espaço próximo da órbita da Terra bem como em reatores nucleares. / Because of their high interface area to volume ratio, nanoparticle systems are intrinsically in a non-thermodynamic-equilibrium state and when submitted to harsh environments these nanomectric structures may loose their functional advantages. In this work we investigate the microstructural changes of Pb nanoparticles embedded in silica films. The modifications were induced by different conditions of thermal annealing and irradiations with electrons and heavy ions. Nanoparticles were formed via Ion Beam Synthesis, combining Pb ion implantation and different steps of thermal annealing and irradiations. Microstructural evolutions were characterized by Rutherford backscattering spectrometry and transmission electron microscopy in conventional mode as well as in-situ, monitoring in real time the changes caused by thermal annealing and irradiation experiments performed inside the microscope. Thermally stable nanoparticles were obtained through an original experimental route develop by our research group. It consists of a long time low temperature annealing which results in the formation of small structures with ≈ 1 nm in diameter that dissociate at temperatures ≈ 600 °C higher than the melting temperature of the metallic bulk Pb. In contrast to what is presented in the literature, our results are discussed considering that the thermal stability of the nanoparticles is due to the formation of Pb clusters with low interface free energy with the SiO2 matrix. Moreover, it was also demonstrated that the thermally stable nanoparticle system evolves in a peculiar way when submitted simultaneously to high temperature annealing and electron irradiations. In particular, the high temperature thermal treatment performed inside the microscope during the observations affects atomic diffusion and also nanoparticle nucleation and growth processes. In-situ experiments allow a clear observation and analysis of the behavior of individual nanoparticles ranging from 3 to 15 nm in diameter when submitted to annealings between 30 °C and 1100 °C. Videos recorded during the in-situ thermal treatment reveal that nanoparticles larger than 3 nm in diameter migrate trough the silica film, presenting Brownian-like motion. The results are discussed considering that migration is caused by inelastic interaction, where the electrons from the microscope break atomic bonds reducing the migration energy barrier of the matrix atoms located at the particle surface. Concerning heavy ion irradiation of large Pb particles (≈ 15 nm in diameter), the main results demonstrate that the bombardment introduce a shape change in these particles, elongating them in the direction parallel to the ion beam incidence. In addition, the irradiation promotes the partial dissolution of the nanoparticles and the formation of nanomectric structures surrounding the central particle. These nanoparticles, named satellites, are thermally stable, maintaining its microstructural characteristics even when annealed at temperatures as high as 1100 °C. To sum up, this thesis presents and discusses new phenomena related to thermal stability of nanoparticles under high temperature and irradiation with electrons and heavy ions. The system formed by Pb nanoparticles embedded in sil ica film can be considered as a model case for the study of the individual and collective particle behavior submitted to harsh environments, similar to those presented in the space and in nuclear reactors.
165

Fabricação de dispositivos com contato túnel para spintrônica em grafeno

Canto, B. January 2014 (has links)
Neste trabalho é apresentado em detalhe a fabricação de dispositivos com contato túnel em grafeno, com foco nas caracterizações físico-químicas de barreiras túnel de Al2O3, crescidas sobre grafeno. Uma investigação detalhada das interfaces Co/Al2O3/grafeno é apresentada. Técnicas de caracterização tais como Raman, AFM, HRTEM, STEM, EDX, EELS são utilizadas, assim como processos de nanofabricação de dispositivos via litografia por feixe de elétrons. Os resultados mostram o crescimento de barreira via nucleação de clusters tipo Volmer-Weber e a existência de contatos Co/grafeno via pinholes através da barreira. A fabricação de barreiras finas com espessura nominal de 1 nm resulta no recobrimento parcial do grafeno por camadas com espessura atingindo cerca de 4 nm. A espessura mínima de barreira para a cobertura total da superfície do grafeno é alcançada através da deposição nominal de uma camada de Al2O3 de 3 nm. A caracterização elétrica dos contatos apresenta um caráter assimétrico, semelhante a um diodo túnel, sendo resultante de componentes de contato túnel, associadas a possível formação de cargas e, também, condução via pinholes, assim como efeitos da geometria dos contatos. / In this work, we report the devices constructions and a detailed investigation of the structural and chemical characteristics of thin evaporated Al2O3 tunnel barriers of variable thickness grown onto single-layer graphene sheets. Advanced electron microscopy (HRTEM, STEM) and spectrum-imaging techniques were used to investigate the Co/Al2O3/graphene/SiO2 interfaces. Direct observation of pinhole contacts was achieved using FIB cross-sectional lamellas. Spatially resolved EDX spectrum profiles confirmed the presence of direct point contacts between the Co layer and the graphene. The chemical nature of the Al2O3 barriers was also analyzed using electron energy loss spectroscopy (EELS). On the whole, the high surface diffusion properties of graphene led to Volmer-Weber-like Al2O3 film growth, limiting the minimal possible thickness for complete barrier coverage onto graphene surfaces using standard Al evaporation methods. The results indicate a minimum thickness of nominally 3 nm Al2O3, resulting in a 0.6 nm rms rough film with a maximum thickness reaching 5 nm. The electrical characterization of the device contacts seems to be a resultant of tunneling contact behavior associated to charge trapping,pinhole contacts and geometry of the contacts.
166

Avaliação das Características Radiográficas de Lesões Intra-ósseas em Maxilares, Através do Estudo de Imagens de Tomografia Computadorizada de Feixe Cônico

SILVA, Amitis Vieira Costa e 28 August 2012 (has links)
Submitted by Lucelia Lucena (lucelia.lucena@ufpe.br) on 2015-03-11T19:43:14Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Dissertação de Mestrado Amitis com Ficha Catalográfica e Folha de apresentação.pdf: 966027 bytes, checksum: b5dc52c94feccb8aaadbe12599bff31a (MD5) / Made available in DSpace on 2015-03-11T19:43:15Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Dissertação de Mestrado Amitis com Ficha Catalográfica e Folha de apresentação.pdf: 966027 bytes, checksum: b5dc52c94feccb8aaadbe12599bff31a (MD5) Previous issue date: 2012-08-28 / Objetivo: o objetivo deste estudo foi avaliar a prevalência das lesões intraósseas e suas características radiográficas associadas. Metodologia: Foi realizado um estudo quantitativo analítico de base de dados, através do estudo de imagens de 623 tomografias computadorizadas de feixe cônico adquiridas por tomógrafo I-CAT New Generation, arquivadas em um banco de dados de uma clínica radiológica. Resultados: O gênero feminino foi o mais prevalente com 66,1%, a média de idade foi de 47,85 anos e a região anatômica posterior da mandíbula foi a mais acometida. As lesões intraósseas que eram associadas aos dentes responderam por 94,7% do total. Quanto às características radiográficas, demonstrou-se que lesões hipodensas com 89,5% dos casos e os aspectos relacionados à baixa agressividade foram as mais prevalentes. Conclusão: O perfil epidemiológico das lesões ósseas nos maxilares nesta população sugeriu significativa relação entre sua presença com processos inflamatórios oriundos de traumas e injúrias ao órgão dental e ao aumento da idade.
167

Análise subjetiva da qualidade da imagem tomográfica de estruturas anatômicas mandibulares de acordo com o tamanho do voxel / Subjective analysis of tomographic image quality of mandibular anatomic structures according to voxel size

Klamt, Carla Beatriz 18 August 2018 (has links)
Orientador: Gláucia Maria Bovi Ambrosano / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-18T00:52:00Z (GMT). No. of bitstreams: 1 Klamt_CarlaBeatriz_M.pdf: 5286411 bytes, checksum: 65fb2bb35f7e7fda1f9ef8b70021bc3d (MD5) Previous issue date: 2011 / Resumo: O objetivo neste trabalho foi comparar de maneira subjetiva a qualidade da imagem tomográfica em exames obtidos e reconstruídos com diferentes tamanhos de voxel. Foram realizadas imagens de 10 mandíbulas humanas maceradas por meio do aparelho de tomografia computadorizada de feixe cônico i-CAT®, utilizando FOV de 6 cm e os seguintes tamanhos de voxel e tempo para cada aquisição: 0,4 mm em 10 segundos; 0,4 mm em 20 segundos; 0,3 mm em 20 segundos; 0,25 mm em 40 segundos e 0,2 mm em 40 segundos. Posteriormente, utilizando-se o software XoranCAT®, foram realizadas as reconstruções multiplanares, sendo os valores de voxels iguais, menores e maiores que os de aquisição, originando 17 grupos. A partir da observação de 10 estruturas anatômicas, cinco examinadores independentes avaliaram a qualidade de imagem em cortes parassagitais por meio de um sistema de escores. As análises de reprodutibilidade inter e intra-examinador foram realizadas pelo coeficiente de correlação intra-classe e a seguir foi calculada a mediana dos escores de qualidade dos cinco avaliadores e os grupos foram comparados pelo teste de Friedman e teste não paramétrico de comparações múltiplas (nível de significância de 5%). Os resultados mostraram que as estruturas anatômicas mais bem observadas nas imagens por TCFC avaliadas nesta pesquisa foram a foramina lingual, o forame mentual e o osso cortical. Já as estruturas de pior observação foram o espaço periodontal e a cortical alveolar. Para todas as estruturas avaliadas, não houve diferença estatística (p>0,05) entre as reconstruções de um mesmo protocolo de aquisição. A aquisição e reconstrução com voxel de 0,2 mm em 40 segundos foi a que apresentou melhor qualidade de imagem para todas as estruturas anatômicas, exceto para a cortical alveolar, na qual não houve diferença entre as aquisições e reconstruções (p>0,05), enquanto as aquisições com voxel de 0,4 mm em 10 segundos, independente do protocolo de reconstrução, apresentaram-se com valores significativamente inferiores (p ? 0,05) ao protocolo de aquisição e reconstrução com voxel de 0,2 mm em 40 segundos / Abstract: The aim of this study was to compare subjectively the tomographic image quality in examinations obtained and reconstructed in different voxel sizes. The images were performed in 10 dry human mandibles using the cone beam computerized tomography scanner i-CAT®, using FOV of 6 cm and the following voxel sizes and acquisition time: 0.4 mm in 10 seconds, 0.4 mm in 20 seconds, 0.3 mm in 20 seconds, 0.25 mm in 40 seconds and 0 2 mm in 40 seconds. Using the program XoranCAT®, multiplanar reconstructions were performed and the voxel values were equal, smaller and larger than those of acquisition, resulting in17 groups. The image quality of 10 anatomical structures was evaluated by five independent observers in parasagittal slices on a score system scale. Inter- and intra-observers agreements were quantified by Intraclass correlation coefficient and after that the median quality scores for the five evaluators was calculated and the groups were compared by the Friedman test and nonparametric multiple comparisons (significance level of 5%). The results showed that the better observed anatomical structures in this study were the lingual foramina, mental foramen and the cortical bone. The less visible structures were the periodontal space and the cortical alveolar. For all the evaluated structures, there was no statistical difference (p> 0.05) among the reconstructions of the same acquisition protocol. The acquisition and reconstruction with a voxel of 0.2 mm in 40 seconds, showed the best image quality for all anatomical structures except the cortical alveolar, in which there was no difference between acquisitions and reconstructions (p> 0.05), while acquisitions with voxel of 0.4 mm in 10 seconds, regardless the reconstruction protocol, presented significantly lower values (p ? 0.05) than the acquisition protocol and reconstruction with a voxel of 0.2 mm in 40 seconds / Mestrado / Radiologia Odontologica / Mestre em Radiologia Odontológica
168

Intensidade de pixel e sua correlação com o índice de qualidade óssea de mandíbulas atróficas / Pixel intensity and its correlation with bone quality index of atrophic mandibles

Jessica Rabelo Mina Zambrana 20 May 2016 (has links)
O sucesso do tratamento de implantes dentários depende da quantidade e qualidade óssea da área de interesse e o uso da Tomografia Computadorizada por Feixe Cônico (TCFC) pode ser correlacionado para a sua estimativa. O objetivo deste estudo foi avaliar e comparar os níveis de escala de cinza dos voxels de imagens obtidas por TCFC de mandíbulas atróficas com o auxílio de programa para diagnóstico e planejamento de implantes e correlacionar a Intensidade Pixel (IP) com a classificação subjetiva do Índice de Qualidade Óssea (IQO). Foram avaliadas imagens tomográficas de 10 mandíbulas atróficas obtidas do banco de dados do LAPI-FOUSP (Laboratório para Análise e Processamento de Imagens) que receberam 8 marcações em regiões normalmente utilizadas para colocação de implantes (4 em região anterior e 4 em região posterior), sobre estas foram posicionados fios ortodônticos para padronização dos cortes tomográficos e simular posições ideais de implantes. Cortes transaxiais das áreas demarcadas foram obtidas para visualização e análise de 4 regiões corticais e 3 regiões trabeculares do tecido ósseo de cada corte, para a seleção de área foi utilizada a ferramenta Região de Interesse (ROI) de cada programa. As imagens foram analisadas por 3 programas de planejamento Romexis (Planmeca,Finlandia), XoranCAT® (Xoran Technologies, EUA) e OsiriX® (Free Software Foundation, 32 bits, EUA). Os dados foram submetidos a análise estatística de Correlação de Spearman em um nível de significância de 5% (p<0,05), análise de correlação intraclasse intra-observador e inter-observador pelo teste Kappa ponderado e o teste qui-quadrado. Os resultados apresentaram que os programas Romexis e OsiriX apresentaram melhor acuidade para a avaliação subjetiva de qualidade óssea, em contrapartida o programa Xoran apresentou inconsistência de dados. Concluiu-se que há correlação entre Intensidade de Pixel e Qualidade óssea de acordo com os resultados encontrados para os programas OsiriX e Romexis / The success of dental implants treatment depends on the bone quantity and quality of the area of interest and the use of Cone Beam Computed Tomography (CBCT) can be correlated to an estimative. The aim of this study was to evaluate and compare the grey scale levels of voxels obtained by CBCT of atrophic mandibles with the aid of software for diagnosis and planning implants and correlates the Pixel Intensity (PI) with the subjective classification of Bone Quality Index (BQI). Tomographic images of 10 atrofic mandibles obtained from the data base of LAPI-FOUSP (Laboratory of analysis and imaging processing) were evaluated, received 8 marks in areas normally used for implant placement (4 in anterior and 4 in posterior region) on these orthodontic wires were positioned for standardization of tomographic images and simulate optimal implant positions. Transaxial slices of the demarcated areas were made for visualization and analysis of four regions of interest for cancellous bone and three regions of interest for cortical bone and for selection of each area a tool called Region of Interest (ROI) was used by each software. The images were analised by three diferent planning software, Romexis (Planmeca, Finland), XoranCAT® (Xoran Technologies, EUA) e OsiriX® (Free Software Foundation, 32 bits, EUA). Data were subjected to statistical analysis of Spearman correlation, intraclass intra-observer and inter-observer analysis correlation and weighted Kappa concordance coefficient with 5% significance level and chi-squared test; The results presented that Romexis and OsiriX software showed better accuracy for subjective assessment of bone quality, on the other hand Xoran software showed data inconsistency. This study concluded that a correlation was found between Pixel Intensity (PI) and Bone Quality (BQ) due to the results of OsiriX and Romexis software.
169

Ultrassom de alta frequência para avaliação da tábua óssea vestibular de implantes dentais / High frequency ultrasound for evaluation of buccal bone surrounding dental implants

Lauren Oliveira Lima Bohner 25 July 2017 (has links)
Objetivo: Avaliar a exatidão do ultrassom de alta frequência na mensuração das dimensões lineares tanto da tábua óssea vestibular como de defeitos periimplantares circundando implantes dentais. Materiais e Métodos: Em uma primeira etapa, implantes dentais (n=10) foram instalados na maxila de 3 crânios secos e escaneados com ultrassom de alta frequência (UAF) e tomografia computadorizada de feixe cônico (TCFC). As seguintes medidas lineares foram determinadas para avaliação: A) espessura óssea; B) nível ósseo. As medições foram comparadas com valores de referência determinados pela microscopia óptica. A segunda etapa do experimento envolveu amostras de osso porcino contendo defeitos ósseos ao redor dos implantes dentais (n=10), as quais foram escaneadas com ultrassom de alta frequência e tomografia computadorizada de feixe cônico. As seguintes medidas foram realizadas nos defeitos periimplantares: A) componente supra-alveolar, B) componente intra-ósseo e C) espessura do defeito. Os valores de referência foram determinado pela microtomografia computadorizada e o erro de medição (diferença entre grupo teste e controle) foi determinado. Os dados foram analisados estatisticamente considerando um nível de significância de p<=0.05. Resultados: Não houve diferença estatisticamente significante entre os grupos para as medições da espessura óssea e nível ósseo (p>0.05). Em relação à espessura óssea, a discrepância foi de 0.17mm para o UAF e 0.02mm para a TCFC. Para o nível ósseo, a discrepância foi de 0.55mm para o UAF e 0.12mm para a TCFC. Ao considerar o erro de medição dos equipamentos na mensuração de defeitos periimplantares, não houve diferença estatisticamente significante entre o UAF e TCFC (UAF= 0.54±0.69mm; TCFC= 0.62±0.55mm). Conclusão: O ultrassom de alta frequência apresentou exatidão para a mensuração das dimensões lineares da tábua óssea vestibular e de defeitos periimplantares circundando implantes dentais. / Purpose: To evaluate the accuracy of a high frequency ultrasound scanner (HFU) to the measurement of buccal bone and periimplant defects surrounding dental implants. Materials and Methods: The first phase of this study comprised the installation of dental implants (n=10) in the maxillary of 3 dry skulls. The dental implants were scanned with a high frequency ultrasound scanner and a cone-beam computed tomography (CBCT). The following measurements were determined for evaluation: A) bone thickness, and B) bone level. The measurements were compared with reference values determined by an optical microscopy. The second phase comprised the installation of dental implants (n=10) in porcine bone samples containing bone defects surrounding dental implants. The bone samples were scanned with a high frequency ultrasound and cone-beam computed tomography and the following measurements were performed: A) supra-alveolar component, B) intra-bony component and C) thickness. The reference values were determined by a micro-computed tomography and the measurement error (difference between experimental and control group) was determined for each group. All measurements were statistically analyzed with a significance level of p<=0.05. Results: There was no statistically significant difference between ultrasound and cone-beam computed tomography for the measurement of buccal bone (p>0.05). With regard to the bone thickness, the discrepancy to the reference values was 0.17mm for HFU and 0.02mm for CBCT. For bone level, the discrepancy was 0.55mm for HFU and 0.12mm for CBCT. The measurement error from both the devices not differed statistically (HFU= 0.54±0.69mm; CBCT= 0.62±0.55mm). Conclusion: The high frequency ultrasound presented accuracy for the measurement of buccal bone and periimplant defects surrounding dental implants.
170

Avaliação da precisão da tomografia computadorizada por feixe cônico (cone beam) como método de medição do volume ósseo vestibular em implantes dentários / Evaluation of the accuracy of computed tomography cone-beam (cone beam) as a method of measuring buccal bone volume in dental implants

Lucy Naomi Shiratori 07 December 2009 (has links)
A monitoração radiográfica das mudanças no nível ósseo fornece sinais valiosos para assegurarmos a longevidade e estética dos implantes. As radiografias periapicais e panorâmicas são importantes instrumentos que permitem esta avaliação, mas tem limitações, pois fornecem imagem bidimensional. As imagens tomográficas fornecem detalhes para estimar dimensões verticais e horizontais, possibilitam a melhor visualização de defeitos ósseos e estruturas anatômicas para o planejamento cirúrgico, além de permitir a monitoração radiográfica pós-cirúrgica ao redor dos implantes. O propósito deste trabalho foi avaliar a precisão da tomografia computadorizada por feixe cônico (TCCB) na medição do volume ósseo vestibular ao redor de implantes. Foram utilizados 8 crânios secos que receberam de 3 a 6 implantes na região da maxila anterior dependendo da disponibilidade óssea, em seguida foi realizada uma TCCB. Por meio dos cortes das imagens, as medições da parede óssea em 3 pontos do implante foram obtidas, analisadas e comparadas às realizadas no modelo do crânio em gesso, que continha implantes da mesma altura e diâmetro, nos mesmos pontos determinados, ou seja, no ápice do implante (A), a 5 mm do ápice (B) e do primeiro contato osso/implante até a plataforma do implante (C). O resultado do estudo mostrou que para os 3 pontos (A, B, C) não houve diferença estatisticamente significante das medidas realizadas no modelo real com a tomografia, ou seja, a TCCB pode ser um instrumento útil para se avaliar longitudinalmente o volume ósseo vestibular, porém, mais estudos clínicos se fazem necessários para ser utilizado na clínica diária. / Monitoring radiographic changes in bone level provides valuable signals to insure the longevity and aesthetics of implants. The panoramic and intra-oral radiographs are important devices for this assessment, but have limitations, they provide twodimensional images. The computed tomographics images provide details to estimate vertical and horizontal dimensions, allow for better visualization of bone defects and anatomical structures important in surgical planning, avoiding anatomical regions that could result in surgical injuries, and allows radiographic monitoring after surgery around implants , a factor of great importance for aesthetics and longevity of implants. The purpose of this study was to evaluate the accuracy of cone beam computed tomography (TCCB) in measuring the buccal bone volume around these implants. 8 skulls were used to install 3 to 6 implants in the anterior maxilla (canine to canine) depending on the availability of bone. These implants were installed in the skull, and then held a TCCB. Through the courts of the images, measurements of the bone wall at 3 points of the implant were obtained, analyzed and compared to those obtained in the model of the skull in plaster. Implants with the same height and diameter were used in the model and the same points determined, ie, the apex of the implant (A), 5 mm from the apex (B) and the first contact implant-bone to the plataform of the implant, were measured. (C).The results showed that for the 3 points (A, B, C) of the implants, no statistically significant difference in measurements obtained from the plaster model and computed tomographics images. Considering the results, TCCB can be a useful tool for assessing buccal bone volume along the implant, however, further studies are needed to be used in clinical practice.

Page generated in 0.0315 seconds