• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 488
  • 7
  • 6
  • 6
  • 6
  • 6
  • 4
  • 4
  • 4
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 510
  • 370
  • 362
  • 357
  • 353
  • 292
  • 287
  • 273
  • 122
  • 68
  • 58
  • 53
  • 53
  • 52
  • 45
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
271

Avaliação comparativa da radiografia panorâmica e da tomografia computadorizada de feixe cônico prévio a extração de terceiros molares inferiores / Comparative evaluation of the panoramic radiograph and cone beam computed tomography prior a lower third molars surgery

Rubens Cardozo de Castro Júnior 29 September 2016 (has links)
A cirurgia de terceiros molares inferiores, não irrompidos, é considerada por muitos uma cirurgia difícil que exige habilidade e treinamento, espera-se, que seja preferencialmente feita por um cirurgião dentista especialista em Cirurgia e Traumatologia Bucomaxilofacial. Acidentes e complicações podem ocorrer no trans e pós-operatório sendo o dano ao nervo alveolar inferior um dos acidentes que podem ser decorrentes da cirurgia de terceiros molares inferiores. O exame complementar por imagem mais prescrito, para observar estruturas anatômicas do complexo maxilomandibular é a radiografia panorâmica, porém, a tomografia computadorizada por feixe cônico pode ser considerado o exame imaginológico mais adequado para identificar mais precisamente a relação dos terceiros molares mandibulares com a anatomia local. Os objetivos deste trabalho foram avaliar planejamento cirúrgico para extração de terceiros molares inferiores entre a radiografia panorâmica e a TCFC e também avaliar e descrever os possíveis acidentes e complicações nas cirurgias para extração dos dentes não irrompidos e correlaciona-los aos achados incidentais imaginológicos. Para isso foram selecionadas 21 radiografias de pacientes da clínica de cirurgia, estomatologia e integrada da Faculdade de Odontologia de Bauru - USP que possuíam indicação de extração de terceiros molares inferiores e que preenchiam o requisito de suspeita de íntimo contato das raízes dos terceiros molares com o canal mandibular, que é uma indicação para a realização de TCFC. Foram realizados extrações de 21 terceiros molares não irrompidos. Durante e após a cirurgia, o cirurgião ficou responsável por realizar a coleta de dados referente a anatomia e possíveis acidentes e complicações decorrentes do ato operatório. Após a cirurgia de terceiros molares inferiores dois examinadores cegos, independentes da seleção das radiografias, do resultado da exodontia e da TCFC, avaliaram primeiramente as radiografias e 30 dias depois, as TCFC. A análise estatística entre os dois métodos foi realizada pelo Teste Exato de Fischer, com nível de significância de 5%. Nos quesitos investigados nesta pesquisa houve diferenças estatísticas significantes na avaliação radiográfica entre os dois radiologistas no item Estreitamento Mandibular e na avaliação tomográfica no item Dilaceração. Sendo possível concluir que ambos exames complementares apresentam imagens suficientes para planejamento de cirurgia dos dentes não irrompidos. / The third molar surgery, impacted or semi-impacted, is considered by many a difficult surgery that requires skills and training, it is expected, which is preferably to be done by a dental surgeon specialist in Oral and Maxillofacial Surgery. Accidents and complications can occur in trans and postoperative, damaging the inferior alveolar nerve one of the accidents that may result from the lower third molar surgery. The most prescribed x-ray to observe anatomical structures of maxilomandibular complex are the panoramic radiograph, however, cone beam computed tomography can be considered the most appropriate one to identify more precisely the relationship of mandibular third molars with the local anatomy. The objectives of this study were to evaluate surgical planning for extraction of third molars between panoramic radiography and CBCT and also assess and describe the possible accidents and complications in surgery for extraction of unerupted teeth and correlates them to incidental findings at imaging examination. For this purpose it was selected 21 radiographs of patients at the clinic of surgery, stomatology and integrated Bauru Dental School - USP that they had indication of lower third molars and also they met the requirements of suspected close contact of the third molar roots with the mandibular canal, which is an indication for performing CBCT. Extractions of 21 third molars unerupted were performed. During and after surgery, the surgeon was responsible for performing and gathering data regarding the anatomy and possible accidents and complications of the surgery. After the third molar surgery two blind independent examiners, without the selection of X-rays or the result of extraction and the CBCT, first evaluated the radiographs and 30 days later, the CBCT. The statistical analysis between the two methods was performed by Fisher\'s Exact Test, with 5% of significance level. The questions investigated in this study had statistically significant differences in radiographic evaluation between the two radiologists on the item Narrowing Mandibular and tomographic evaluation in Laceration item. Being possible to conclude that both additional tests have enough images for planning surgery of unerupted teeth.
272

Avaliação do comportamento de seladores endodônticos e a influência destes materiais sobre o diagnóstico de fraturas radiculares por meio de tomografia computadorizada por feixe cônico / Endodontic fillings behavior evaluation and their influence in root fracture diagnosis by means of cone beam computed tomography

Fernanda Cristina Sales Salineiro 20 April 2018 (has links)
A tomografia computadorizada por feixe cônico (TCFC) tem apresentado melhores resultados em relação a radiografia convencional no diagnóstico da região de cabeça e pescoço. Porém a presença de artefatos nas imagens tomográficas podem interferir na acurácia do diagnóstico. O presente estudo teve como objetivo avaliar a influência de diferentes tipos de preenchimentos endodônticos na formação de artefato nas imagens de TCFC e avaliar a influência destes no diagnóstico de fratura radicular. Foram utilizados 200 dentes (100 incisivos centrais superiores e 100 prémolares inferiores) subdivididos em 10 grupos diferenciando o tipo de preenchimento endodôntico. Os dentes foram escaneados utilizando um tomógrafo computadorizado por feixe cônico. Inicialmente foi realizada uma medição nas imagens tomográficas com a ferramenta de informação sobre a área (ROI) e avaliação subjetiva das imagens para realizar uma comparação entre os cimentos endodônticos. Após essa fase, 100 dentes foram fraturados para realizar a última análise que foi o diagnóstico de fratura radicular. Para análise dos dados da ferramenta ROI foram utilizados a análise de Kruskal-Wallis e o teste post hoc Dunn, para comparar os dados subjetivos foi utilizado o teste de Kruskal-Wallis e para os dados de diagnóstico de fratura radicular foi calculado a Curva de característica de operação do receptor (ROC) e o teste ANOVA e o teste post hoc Tukey para os valores de área sob a curva (ASC). Resultados: O terço médio foi a região que gerou mais variações na escala de cinza para ambos os dentes. O Pulp Canal Sealer e o Sealer 26 foram os cimentos que mais alteraram as imagens segundo a análise subjetiva. Os valores de ASC variaram de 0.530 a 0.745. Conclusão: Todos os materiais produziram artefato nas imagens por TCFC, dificultando o diagnóstico de fratura radicular. / Cone beam computed tomography (CBCT) has shown better results than conventional radiographs on head and neck diagnosis. However, the presence of artifact in the CBCT images could interfere on diagnosis accuracy. The aim of this study was to evaluate the influence of different types of endodontic fillings and analyze the influence of these materials in root fracture diagnosis. Two hundred teeth (100 superior incisors and 100 inferior premolars) were divided in 10 groups categorized by each typo of endodontic filling. All teeth were scanned by using CBCT device. Initially, a measurement was performed on CBCT images using the Region of Interest (ROI) tool and a subjective analysis of the images was carried on to compare the different endodontic fillings. After this phase, 100 teeth were fractured to perform the last analysis: root fracture diagnosis. Kruskall-Wallis analyses for ROI tool data was performed with the aid of post hoc Dunn test, Kruskal-Wallis test was selected for the subjective data assessment and receiver operating characteristic (ROC) curves were used for root fracture diagnosis analyses and the variance analysis with the post hoc Tukey test for AUC values. The middle third was the region that developed more grayscale variations for both teeth. At the subjective analysis, Pulp Canal Sealer and Sealer 26 were selected as the ones that produced more images alterations. AUC ROC values ranged from 0.530 to 0.745. Conclusion: All materials produced artifact in CBCT images, making the root fracture diagnosis more difficult.
273

Avaliação das alterações nas vias aéreas superiores através de tomografia computadorizada Cone-Beam em pacientes submetidos à cirurgia ortognática de avanço bimaxilar /  

Luis Fernando Azambuja Alcalde 30 March 2017 (has links)
Os softwares de avaliação em três dimensões revolucionaram os planejamentos da cirurgia ortognática. Com eles é possível realizar desde simulações dos movimentos cirúrgicos, até avaliação das vias aéreas superiores (VAS) em volume e área, o que não era possível nas radiografias bidimensionais. Muitos pacientes recorrem à cirurgia ortognática com finalidade de melhorar a oclusão e a estética. Dependendo da movimentação cirúrgica, o espaço aéreo pode aumentar ou diminuir. O presente trabalho tem como objetivo avaliar as alterações de área e de volume do espaço aéreo faríngeo em pacientes submetidos à cirurgia ortognática de avanço bimaxilar. Foi realizada a análise da área axial mínima e do volume aéreo superior pré-operatório (T0) e pós-operatório (T1) de 50 pacientes, sendo 17 do sexo masculino e 33 do sexo feminino, com média de idade de 36,6 (±12,1) anos. As avaliações foram feitas através de tomografia computadorizada de feixe cônico, utilizando o Programa Nemoceph 3DOS. Foi utilizado o teste ´´t`` pareado para comparar os dados pré e pós-operatórios de volume e o teste de Wilcoxon para comparar os dados pré e pós-operatório de área axial mínima. Todos os testes foram realizados com o programa Statistica, adotando um nível de significância de 5%. No estudo do erro do método, não houve erro casual nem sistemático entre a primeira e a segunda aferição das variáveis (p > 0,05 em todas as medidas). A cirurgia de avanço bimaxilar apresentou uma média de 70,46% (59,38) de aumento volumétrico e uma mediana de 61,27% de aumento na área axial mínima, onde a mesma variou de -22,50% à 659,06%. Com este trabalho, conclui-se que o avanço bimaxilar proporciona um aumento significativo de volume e área axial mínima das vias aéreas superiores, porém este ganho não é homogêneo em todos os pacientes. / Software in three dimensions has come to revolutionize the orthognathic surgery planning. With them it is possible to perform from simulations of the surgical movements, until evaluation of the upper airways in volume and area, which wasnt possible in two dimensions software. Many patients resort to orthognathic surgery in order to improve occlusion and facial profile. Depending of the surgical movements, the airway space may increase or decrease. The aim of the study is to evaluate the changes in the area and volume of the pharyngeal airway space in patients submitted to bimaxillary advancement in orthognathic surgery. It was analyzed the minimum axial area and the volume of the pharyngeal airway space preoperative (T0) and postoperative (T1) air volumes of 50 patients, which 17 were male and 33 were female, with a mean age of 36.6 (± 12.1) years. The evaluations were done using Cone-beam computed tomography in Nemoceph 3D-OS Program. It was used the paired t test to compare the pre and postoperative volume data and the Wilcoxon test to compare the pre and postoperative data of the minimal axial area. All the tests were performed with the Statistica program, adopting a level of significance of 5%. In the study of the method error, there was no casual or systematic error between the first and second measurements of the variables (p> 0.05 in all measurements). The bimaxillary advancement surgery presented a mean of 70.46% (59.38) of volumetric increase and a median increase of 61.27% in the minimum axial area, that varied from -22.50% to 659.06%. In this study, it was concluded that bimaxillary advancement provides a significant increase in volume and minimum axial area of the upper airways, but the increase it isnt homogeneous in all patients.
274

Influência Dos Materiais Endodônticos na Produção de Artefatos de Imagem em Tomografia Computadorizada de Feixe Cônico

SOUZA, Rafaella Maria Silva de 24 February 2015 (has links)
Submitted by Fabio Sobreira Campos da Costa (fabio.sobreira@ufpe.br) on 2016-06-27T12:45:42Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Dissertação - Rafaella maria Silva de Souza.pdf: 1989713 bytes, checksum: cd83e58aaa8eb66c26381019b48510e8 (MD5) / Made available in DSpace on 2016-06-27T12:45:42Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Dissertação - Rafaella maria Silva de Souza.pdf: 1989713 bytes, checksum: cd83e58aaa8eb66c26381019b48510e8 (MD5) Previous issue date: 2015-02-24 / CAPEs / Objetivo deste estudo foi verificar a influência dos materiais endodônticos, tecidos radiculares e posição dos dentes na produção de artefatos em Tomografia Computadorizada de Feixe Cônico (TCFC). Quarenta e oito pré-molares humanos inferiores foram distribuídos em dois grupos controles: dentes sem instrumentação e dentes instrumentados e quatro grupos experimentais, nos quais, após a instrumentação adicionou-se: guta-percha, guta-percha+Sealer 26, guta-percha+AH Plus e guta-percha+FillCanal. Os dentes foram montados em uma mandíbula para a exposição com o i-Cat em resoluções de 0.125 e 0.2mm de voxel. Três radiologistas avaliaram as imagens no formato pdf. A concordância para a presença e intensidade de artefatos intra e inter-avaliador variou de 0.79-0.96 e 0.54-0.95 (Kappa), respectivamente. Diferentes posições nos alvéolos não interferiram na produção de artefatos (p=1.000; teste Exato de Fisher). A maior parte das imagens foi classificada como excelente e boa (grupos controles) e boa e regular (grupos experimentais). Em todas as avaliações dos grupos experimentais foram observados artefatos. Em relação à intensidade dos artefatos, houve diferença significativa apenas no terço radicular cervical do AH Plus com resolução 0.125mm (p≤0.05; teste Exato de Fisher). Imagens com resolução de 0.2 mm, sugeriram presença de fratura no grupo Guta-percha e Guta-percha+Ah Plus. Todos os materiais de preenchimento produziram artefatos, reduzindo a qualidade da imagem para o auxílio no diagnóstico. Os tecidos radiculares e a posição do dente não interferiram na formação de artefatos. Dependendo da finalidade diagnóstica, é indicada a exposição com resolução de 0.125mm, por apresentar dose de radiação equivalente à de 0.2mm e imagens com melhor qualidade. / The aim of this study was to investigate the influence of endodontic filling materials, root tissues and position of the teeth in the production of Artifacts in Cone-Beam Computed Tomography (CBCT). Forty-eight human lower premolars were divided into two control groups (C1 teeth without instrumentation, C2 instrumented teeth) and four experimental groups, in which, after instrumentation ,gutta-percha, gutta-percha + Sealer 26, gutta-percha + AH Plus and gutta-percha + FillCanal were added. The teeth were mounted on a jaw for exposure with i-Cat in resolutions 0.125 and 0.2 mm voxel. Three radiologists evaluated the images in pdf format. The agreement for the presence and intensity of intra and inter-rater artifacts ranged from 0.79-0.96 and 0.54-0.95 (Kappa), respectively. Different positions in the alveoli did not affect the production of artifacts (p = 1.000; Fisher's exact test). The images (99%) were classified as excellent or good (control groups) and good and regular (experimental groups). Image artifacts were observed in all evaluations of the experimental groups. Regarding the intensity of the artifacts, there was a significant difference only in the cervical root third of AH Plus with Resolution 0.125mm (p≤0.05; Fisher's exact test). Images with 0.2 mm resolution, suggested fracture presence in Guta-percha group and Gutta-percha + Ah Plus. All filling materials produced artifacts, reducing image quality to aid in diagnosing. The root tissue and position of the tooth did not interfere in the formation of artifacts. Depending on the diagnostic purposes, it is indicated exposure with resolution of 0.125mm, to present radiation dose equivalent to 0.2mm and images with better quality.
275

Investigação da prevalência e morfologia do segundo conduto na raiz mésiovestibular em primeiros molares superiores por meio de tomografia computadorizada de feixe cônico de pequeno volume e alta resolução em uma população do Brasil / Investigation of prevalence and morphology of the second canal in the mesiobuccal root of maxillary first molars in cone beam computed tomography of small volume and high resolution in a population of Brazil

Cláudia Rezende Gomes Alves 05 August 2016 (has links)
Primeiros molares superiores (1oMS) podem apresentar na sua raiz mésio-vestibular um segundo conduto (MV2) que é geralmente de pequena dimensão e grande variação anatômica. Os MV2 são de difícil visualização em radiografias convencionas (bidimensionais) o que pode ser causa importante de insucessos de tratamentos endodônticos. Este problema pode ser solucionado pelo uso de um método imaginológico mais sensível como a tomografia computadorizada por feixe cônico (TCFC). Com o objetivo de determinar, pela primeira vez na literatura, a prevalência e a morfologia do conduto MV2 numa população brasileira foram avaliadas 414 TCFC, de pequeno FOV (5 ou 8) e alta resolução tomadas para fins de diagnósticos num intervalo de 2 meses. Destas foram selecionadas as TCFCs de 186 mulheres e 101 homens, com idades entre 9 e 93 anos (média de 49,43 ± 16,76), que apresentavam ao menos um 1oMS, totalizando 362 dentes. Para avaliar a reprodutibilidade na detecção do conduto MV2 nas TCFC todas as imagens foram avaliadas por três examinadores diferentes e os dados foram comparados pelo teste Kappa. Obteve-se como resultado alta reprodutibilidade interobservadores (Kappa entre 0,79 e 0,88; p<0,0001). Assim sendo, os dados obtidos de apenas 1 dos examinadores foram avaliados estatisticamente por testes ANOVA, ou Kruskal Wallis e de Correlação de Pearson (p<=0,05). O conduto MV2 foi detectado em 68,23% dos 1osMS avaliados. A raiz mésiovestibular destes dentes apresentou predominantemente o Tipo II (38,12%) da classificação de Vertucci (1984). A presença do conduto MV2 foi significativamente maior em pacientes com idades menores (média de 45.04; p<0,01) que daqueles que não apresentaram o MV2 (média de 53.46). Não houve correlação entre a presença de conduto MV2 tanto com relação ao gênero (p=0,14), nem ao lado do 1oMS (p=0.53), quanto ao tamanho do FOV (p=0.09) da TCFC. Houve correlação negativa significativa (p=0.008) entre a classificação de Vertucci do MV2 e o tamanho do FOV da TCFC, ou seja, TCFC de FOV menor (FOV 5) encontraram MV2 com tipos maiores da classificação de Vertucci. Setenta e cinco pacientes apresentavam os 2 1osMS nas TCFCs, destes 58 pacientes (77,33%) apresentaram ou presença ou ausência do conduto MV2 simultaneamente em ambos lados. As idades dos pacientes que apresentaram o conduto MV2 nos dentes de ambos os lados (44; 58,66%) foram significativamente menores que daqueles que não apresentaram o conduto MV2 em nenhum dos lados (14; 18,66%) e também em somente um dos lados (17; 22,66%) (p<0,05). Concluiu-se que há alta prevalência do conduto MV2 na população examinada que ocorrem predominantemente em indivíduos jovens. Mais ainda, a detecção do MV2 independe do tamanho do FOV, porém TCFCs de FOV menor são mais sensíveis na análise de detalhes anatômicos destes condutos. / Upper first molars (UFM) may have on their mesiobuccal root a second canal (MB2), which is usually small and with large anatomical variation. The MB2s are difficult to detect in conventional radiographs (two-dimensional) and can be a major cause of failure of endodontic treatments. This problem could be circumvented by using a more sensitive imaginologic method as cone beam computed tomography (CBCT). In order to determine for the first time in the literature the prevalence and morphology of MB2 canal in a Brazilian population 414 CBCTs of small FOV (5 or 8) and high resolution taken for diagnostic purposes in a 2-month interval were evaluated. Of these, CBCTs of 186 women and 101 men, aged 9 to 93 years old (mean age 49.43 ± 16.76) who had at least one UFM were selected, totaling 362 teeth. To assess the reproducibility of the MB2 canal detection in CBTCs three different investigators evaluated all images and the data were compared with the Kappa\'s test. A high interobserver reproducibility (Kappa between 0.79 and 0.88; p <0.0001) was observed. Then, the data obtained from only one of the examiners were analyzed by ANOVA or Kruskal Wallis and Pearson\'s correlation (p <= 0.05). The MB2 canal was detected in 68.23% of the UFM examined. The mesiobuccal root of these teeth predominantely presented the Type II (38.12%) according to Vertucci\'s classification (1984). The presence of MB2 was similar in both genders female and male (p=0,14) and significantly higher in patients with younger ages (mean 45.04 years old, P <0.01) than in those who did not present the MB2 (average 53.46 years old). There was no correlation between the presences of MB2 canal in relation to the side of the UFM (p = 0:53), as well as to the size of the FOV (p = 0:09). There was a significant negative correlation (p = 0.008) between the Vertucci\'s classification of MB2 and the size of FOV (i.e. the smaller FOV detected MB2 with higher Vertucci\'s types). Seventy-five patients had 2 UFM in the CBTCs, from these 58 patients (77.33%) showed the presence or absence or MB2 canal simultaneously on both sides. The ages of the patients with MB2 in teeth on both sides (44; 58.66%) were significantly smaller than those of patients who did not presente the MB2 on either side (14; 18.66%) or in only side (17; 22.66%) (p <0.05). It was concluded that there is high prevalence of MB2 in the examined population, which occurred predominantly in young individuals. Moreover, the detection of MB2 does not dependent on the size of FOV but CBTCs of smaller FOV are more sensitive in the analysis of anatomical details of these canals.
276

Utilização da tomografia computadorizada de feixe cônico na obtenção dos índices radiomorfométricos em mulheres na pré e pós menopausa / Use of cone beam computed tomography in obtaining radiomorphometric index in women in pre and postmenopausal

Daniela Miranda Richarte de Andrade Salgado 01 July 2016 (has links)
O rastreio de osteoporose utilizando imagens de tomografia computadorizada de feixe cônico (TCFC) é um procedimento ainda discutível. O objetivo deste estudo foi avaliar a qualidade óssea de mulheres de diversas faixas etárias (AG) através de índices de radiomorfométricos obtidos em TCFC. Setenta e cinco imagens de TCFC de mulheres (idades compreendidas entre 40 - 70 anos) foram avaliadas. Os pacientes foram agrupados de acordo com AG, em três maneiras diferentes, de acordo com a prevalência de osteoporose em mulheres brasileiras. Os índices avaliados foram: índice cortical mandibular (ICM), índice mentual (IM) e os índices de tomografia computadorizada superior e inferior (ITC). Dois examinadores calibrados avaliaram as imagens em três tempos: Abertura / reconstrução de imagens (1), repetindo este procedimento e salvando a reconstrução (2), e a avaliação das imagens reconstruídas (3). As reconstruções panorâmicas (variando as espessuras: 0,30, 10, e 20 mm) e imagens transaxiais foram avaliadas. A concordância intra e inter-examinador foram avaliadas por meio do teste Kappa e estatísticas de coeficiente de correlação intraclasse. A correlação de Pearson foi utilizada para verificar a relação entre os índices avaliados e AG. O teste de quiquadrado foi utilizado para comparar a prevalência de osteoporose de acordo com cada parâmetro e AG. Os índices avaliados não apresentaram correlação com AG. Alta concordância intra e inter-examinador foi encontrada para IM e ITC, mas não para ICM. A prevalência da osteoporose variou grandemente, de acordo com o índice avaliado e o valor de corte utilizado para definir a doença (com base na qualidade do osso). Os índices radiomorfométricos quantitativos obtidos na TCFC podem ser avaliados de uma forma reprodutível. Não houve correlação entre os índices e AG, o que sugere que as imagens de TCFC não devem ser utilizadas para o rastreio de osteoporose. / Screening for osteoporosis using cone beam CT images (CBCT) is a datable procedure. The aim of this study was to evaluate the bone quality of women from diverse age groups (AG) using CBCT-based radiomorphometric indices. Seventy-five CBCT images of women (age range 40 - 70) years were evaluated. Patients were grouped according to AG, in three diverse manners, according to prevalence of osteoporosis in Brazilian women. The mandibular cortical (MCI), mental (MI), and the superior and inferior computed tomography (CTI) indices were assessed. Two calibrated examiners assessed the images in three instances: opening/reconstructing the images (1), repeating this procedure (2), and assessing the reconstructed images once again (3). Panoramic reconstructions (0.30, 10, and 20 mm thicknesses) and cross-sectional images were assessed. Intra and inter-examiner agreement were assessed by means of Kappa and intraclass correlation coefficient statistics. Pearson correlation was used to verify the relationship between the assessed indices and AG. Chi-square statistics was used to compare the prevalence of osteoporosis according to each index and AG. Assessed indices showed no correlation with AG. High intraand inter-examiner agreement was found for MI and CTI but not to MCI. The prevalence of osteoporosis varied widely, according to the assessed index and to the cutoff used to define the disease (based on bone quality). Quantitative CBCT-based radiomorphometric indices can be assessed in a reproducible manner. No correlation between AG and the assessed indices was found, suggesting that CBCT images should not be used for the screening of osteoporosis.
277

Comparação da precisão e acurácia de medidas lineares com diferentes protocolos de tomografia computadorizada por feixe cônico / Comparison of accuracy and precision of linear measurements with different cone beam computed tomographic protocols

Jun Ho Kim 25 May 2018 (has links)
Uma das complicações mais importantes relacionadas com o tratamento de implante dentário é a peri-implantite. Devido a limitação pela sobreposição de estruturas da técnica periapical, nos casos da perda óssea peri-implantar nas faces vestibulares e linguais ou palatais necessita-se de um exame capaz de prover imagens em 3 dimensões para o correto diagnóstico, sendo as imagens de tomografia computadorizada por feixe cônico (TCFC) as mais indicadas. O objetivo deste estudo foi avaliar a acurácia, especificidade, sensibilidade, concordância inter e intraobservadores e determinar a influência dos artefatos na detecção dos defeitos ósseos peri-implantares simulados em mandíbulas humanas edêndulas secas. Foram utilizados dois aparelhos de TCFC com diferentes protocolos de aquisição: i-CAT Gendex CB-500(120kVp, 5mA) e ORTHOPANTOMOGRAPH OP300(90kVp, 6.3mA). Foram instalados 24 implantes dentários cilíndricos e executados dezesseis defeitos somente nas faces vestibulares, com os comprimentos que variaram de 0,5mm a 15mm. Somente cortes sagitais foram utilizados para avaliação qualitativa e quantitativa dos defeitos foi realizada por meio de Image J. Os resultados do teste de concordância intra e inter-observadores tanto nas avaliações qualitativas e quantitativas foram predominantemente fracos. Os valores de Área Sob a Curva (ASC) variaram de 0.51 a 0.72 no i-CAT Gendex CB-500; e no ORTHOPANTOMOGRAPH OP300 variaram de 0.54 a 0.75, demonstrando desempenho diagnóstico ligeiramente superior. Nas imagens obtidas em aparelho com 120kVp (i-CAT Gendex CB-500) foram observados maior contraste em relação ao aparelho 90kVp (ORTHOPANTOMOGRAPH® OP300); em aparelho com o menor kVp (OP300) formaram mais artefatos e estes, degradaram a qualidade das imagens e influenciaram o desempenho diagnóstico das TCFCs na detecção e nas mensurações de perda óssea peri-implantar. Os protocolos de aquisições diferentes podem influenciar no aumento ou redução da formação dos artefatos. / One of the most important complications related to dental implant treatment is periimplantitis. Due to the structures overlapping inherited to periapical technique, in cases of buccal and lingual or palatal bone loss in peri-implantitis, the 3 dimensions observation exam like cone beam computed tomography(CBCT) is most indicated. The objective of this study was to evaluate the accuracy, specificity, sensitivity, interand intra-observer agreement and to determine the influence of the artifacts in the detection of the peri-implant bone defects simulated in human dry mandibles. The two CBCT devices with different acquisition protocols were used in this study: i-CAT Gendex CB-500 (120kVp, 5mA) and ORTHOPANTOMOGRAPH OP300 (90kVp, 6.3mA). Twenty-four cylindrical dental implants were placed and 16 defects were prepared only on buccal faces, the defect lengths ranged from 0.5mm to 15mm. For qualitative and quantitative assessment, only sagittal slices were evaluated by the observers, using Image J software. The results of intra and inter-observer agreement tests in both assessments were generally poor. The AUC values ranged from 0.51 to 0.72 on the i-CAT Gendex CB-500; and in the ORTHOPANTOMOGRAPH OP300 ranged from 0.54 to 0.75, showing slightly higher diagnostic performance. Higher contrast was observed in the 120 kVp device\'s images (i-CAT Gendex CB-500) when compared with the 90 kVp device\'s image (ORTHOPANTOMOGRAPH® OP300). The low kVp device (OP300), formed more artifacts which degraded the image quality and influenced the CBCT diagnostic performance in the detection and measurement of peri-implant bone loss. Different CBCT acquisition protocols may influence increasing or reducing artefact formation.
278

Estudo da tomografia computadorizada de feixe cônico na avaliação morfológica de raízes e canais dos molares e pré molares da população brasileira / Study of cone beam computed tomography in the evaluation of roots and canals morphology of molars and premolars in the Brazilian population

Bruno Vieira Caputo 10 February 2015 (has links)
Um dos fatores que influenciam o sucesso no tratamento endodôntico é o conhecimento anatômico do sistema de canais radiculares. Devido as dificuldades apresentadas nas avaliações do número de raízes e canais por métodos radiográficos convencionais, a Tomografia Computadorizada de Feixe Cônico (TCFC) se mostra de grande importância na avaliação morfológica de canais radiculares. O presente estudo teve como objetivo avaliar a morfologia dos primeiros pré molares e molares, superiores e inferiores, através da TCFC relacionando com gênero e posição. Foram incluídos no estudo 264 imagens de TCFC de pacientes (144 mulheres e 120 homens), representando um total de 1560 dentes avaliados divididos no quatro grupos de dentes estudados. Na avaliação dos dentes 1ºMI, as mulheres apresentaram com maior frequência 2 canais na raiz distal do lado direito (p = 0,002) do que os homens. E para os dentes 1ºPMS, na raiz única, em ambos os lados, observou-se que as mulheres apresentaram mais canais (p = 0,028 e 0,001, para os lados direito e esquerdo, respectivamente). Porém neste grupo de dentes, observou-se nos homens 2,23 vezes mais chance de apresentarem mais raízes bilaterais, e 2,69 vezes mais chance quando considerar ao menos uma raiz extra. Os resultados indicam que não podemos tratar os dentes provenientes do mesmo paciente como observações independentes em estudos de avaliações de canais radiculares, devido a alta concordância entre os dentes apresentados bilateralmente pelos pacientes. E conclui-se que a população brasileira difere de outras populações em relação a diferentes morfologias de canais radiculares, sendo assim mais estudos devem ser realizados com o objetivo de auxiliar no diagnóstico e tratamento endodôntico. / One of the factors that influence success in endodontic treatment is the anatomical knowledge of the root canal system. Because the difficulties presented in the evaluations of the root canals by conventional radiographic methods, Cone Beam Computed Tomography (CBCT) shown of great importance in the morphology of root canals. This study aimed to evaluate the morphology of the first mandibular molars and premolars, and the first maxillary molars and premolars, by CBCT relating to gender and position. The study included 264 patients CBCT images (144 women and 120 men), representing a total of 1560 teeth examined divided in four groups of teeth studied. In the evaluation of first mandibular molar women have more often two channels on the distal root of the right side (p = 0.002) than males. And maxillary first premolars on single root, on both sides, it is observed that women had more root canals (p = 0.028 and 0.001 for the right and left sides, respectively). But this group of teeth, in men showed 2.23 times more chances to had bilateral extra roots, and 2.69 times more chances when considering at least one extra root. The results showed that couldn\'t treat the teeth from the same patient as independent observations in the root canal reviews studies, due to the high correlation between the teeth presented by the patients bilaterally. And it is concluded that the Brazilian population differs from other populations for different morphologies of root canals, so more studies are needed in order to aid in the diagnosis and endodontic treatment.
279

Avaliação volumétrica de defeitos ósseos em fissuras de rebordo alveolar e palato duro por meio da 3D-TC multislice e feixe cônico / Volumetric assessment of hard palate and alveolar cleft using multislice and cone beam 3DCT

Marco Antonio Portela Albuquerque 11 November 2010 (has links)
As fissuras de rebordo alveolar e palato duro estão entre as malformações mais frequentes do corpo humano, podendo causar extensas deformidades ósseas faciais, com implicações biopsíquico-sociais marcantes. A avaliação da extensão desses defeitos ósseos, através de exames por imagem, tem sido feita com o objetivo de diagnosticar e planejar a terapêutica reabilitadora dos pacientes. O presente estudo tem por objetivo desenvolver uma metodologia de pós-processamento de imagens tomográficas para avaliação volumétrica de defeitos ósseos confeccionados em palato duro e rebordo alveolar de crânios macerados, mimetizando fissuras trans-forâmens unilaterais, e verificar a aplicabilidade clínica do Tomógrafo Computadorizado espiral Multislice e do tomógrafo computadorizado por feixe cônico na análise desses defeitos. Para tanto, nove crânios provenientes da Faculdade Cathedral, da cidade de Boa Vista- RR, foram escaneados em um Tomógrafo Computadorizado Multislice pertencente ao Hospital Geral de Roraima e em um tomógrafo computadorizado por feixe cônico de uma clínica privada, na cidade de Fortaleza-CE. As imagens foram, posteriormente, encaminhadas para análise ao Laboratório em Terceira Dimensão(LAB-3D) da Faculdade de Odontologia da USP, utilizando-se uma estação de trabalho independente e aplicando-se programas específicos de computação gráfica. Todas as imagens foram analisadas por dois examinadores, individualmente e em tempos distintos, por duas vezes, com o objetivo de processarmos análises intra e interexaminadores. Para a análise da metodologia de processamento de imagens, comparamos os resultados obtidos pelo Tomógrafo multislice utilizando crânios sem cera e com cera de modelagem número 07, na região do defeito ósseo, para auxiliar no seu delineamento, durante o pós-processamento das imagens tomográficas. Foram também avaliados os resultados volumétricos obtidos nos dois tipos de tomógrafos,com o objetivo de verificar a aplicabilidade dessas tecnologias na avaliação volumétrica dos defeitos ósseos fissurais e de comparar os resultados obtidos por cada uma delas. Todos os resultados foram comparados com os valores estabelecidos pelo padrão - ouro de nossa análise, que foram obtidos através do princípio de Arquimedes de deslocamento de água dos modelos de cera que foram utilizados. Os resultados estatísticos demonstraram que a metodologia de processamento das imagens tomográficas apresentou uma eficácia bastante elevada (p=0,995), sendo considerada eficiente na avaliação volumétrica de defeitos ósseos fissurais. Com relação aos tomógrafos utilizados, observamos que tanto o multislice como o por feixe cônico também apresentaram resultados satisfatórios, apresentando grande confiabilidade para o estudo do volume dos defeitos ósseos fissurais (p=0,997 e p=0,981, respectivamente), não havendo diferença nos resultados encontrados por eles. As análises intra e interobservadores nos dois tipos de tomógrafos não demonstraram diferença estatisticamente significativa. Os resultados evidenciaram que, independente do tipo de tomógrafo utilizado e do avaliador, as medidas obtidas são estatisticamente iguais às conseguidas pelo padrão-ouro de nossa análise. A aplicabilidade clínica de nossa pesquisa demonstrou ser direta e imediata, sendo importante no processo diagnóstico/terapêutico dos pacientes portadores de fissuras de rebordo alveolar e palato duro. / Oral clefts are one of the most frequent malformations of the human body, causing extensive facial bone deformities, compromising biological, psychic and social the individuals affected. Multislice CT and CBCT have been used to assess the volume of bone defect with the goal of diagnosis and rehabilitative therapy planning of the patients. The aim of this study were to develop a methodology for post-processing of tomographic images for volumetric assessment of bone defects made in the hard palate and alveolar ridge of dry skulls, mimicking unilateral trans-foramen clefts; and to determine the clinical applicability of multislice spiral computed tomography, and cone beam computed tomography in the analysis of these defects. Nine dry skulls from the Cathedral College in Boa Vista-RR were scanned on a multislice CT scanner at the Hospital Geral de Roraima and a cone beam computed tomography in a private clinic in Fortaleza-CE. The images were sent for analysis at Three Dimensional Laboratory (LAD-3D) of the Dentistry School, São Paulo University, using an independent workstation and implementing specific computer graphics programs. All images were analyzed by two examiners at different times and twice to proceed the intra and inter-examiners analysis. For analysis the methodology of image processing, we compared the results obtained by multislice CT using skulls with and without wax model in the region of bone defect. It was also analyzed the same images in both types of CT scanners in order to determine the applicability of these radiographic techniques in assessing volume of the clefts and to compare the results. All results were compared with the gold standard of our analysis, which was obtained by Archimedes principle of water displacement of wax models. The statistical results showed that the post processing methodology of tomographic images showed a high efficiency (p = 0.995) and was considered an efficient method for volumetric assessment of fissure bone defects. It was also observed that both multislice CT and cone beam CT showed excellent results with high reliability in the study of the volume of bone defects (p = 0.997 and p = 0.981, respectively), with no difference in performance between them. Analysis of intra-and inter-observer in the two types of CT scanners showed no statistically significant difference. The results demonstrate that independent of the type of CT scanner and the appraiser, the measurements are statistically equal to the gold standard obtained by our analysis. The clinical applicability of our research has shown to be immediate and direct, and it is important for the diagnostic and therapeutic process of patients with oral cleft.
280

Análise da correlação entre índices radiomorfométricos de densidade óssea, perfil de qualidade óssea em software de implante, quociente de estabilidade e torque de inserção em implantes / Analyses of the correlation among radiomorphometric indices of bone density, bone quality profile using a software implant, stability quotient, and insertion torque implants

Rodrigo Alves Ribeiro 04 March 2016 (has links)
A qualidade óssea, bem como a estabilidade inicial dos implantes, está diretamente relacionada com o sucesso das reabilitações na implantodontia. O presente estudo teve como objetivo analisar a correlação entre índices radiomorfométricos de densidade óssea por meio de radiografias panorâmicas, perfil de qualidade óssea com o auxílio de Tomografia Computadorizada de Feixe Cônico (TCFC) com o uso do software de imagens OsiriX, Análise da Frequência de Ressonância (RFA) e Torque de Inserção do implante. Foram avaliados 160 implantes de 72 indivíduos, com média etária de 55,5 (±10,5) anos. Nas radiografias panorâmicas foram obtidos os índices IM, IPM e ICM, e nas tomografias computadorizadas de feixe cônico, os valores de pixels e a espessura da cortical da crista óssea alveolar, além da estabilidade primária por meio do torque de inserção e análise da frequência de ressonância. Os resultados foram analisados pelo coeficiente de correlação de Spearman, para p<= 0,01 foi obtido entre o torque de inserção e valores de pixels (0.330), o torque de inserção e a espessura da cortical da crista alveolar (0.339), o torque de inserção e o ISQ vestibulo-lingual (0.193), os valores de pixels e espessura da cortical da crista alveolar (0.377), as duas direções vestíbulo-lingual e mesio-distal do ISQ (0.674), o ISQ vestíbulo-lingual e a espessura da cortical da crista alveolar (0.270); os índices radiomorfométricos foram correlacionados entre eles e para p<= 0,05 foi obtido entre torque de inserção e ISQ mesio-distal (0.131), entre o ISQ vestibulo-lingual e os valores de pixels (0.156) e ISQ mesio-distal e IPMI esquerdo (0.149) e ISQ mesio-distal e IPMS esquerdo (0.145). Existe correlação entre a TCFC, o torque de inserção e a RFA na avaliação da qualidade óssea. É possível utilizar, pré-cirurgicamente, os exames de TCFC para avaliar a qualidade e quantidade óssea, tendo em vista as correlações obtidas neste estudo. / The bone quality and initial stability of implants are directly related to the success of rehabilitation in implantology. The aim of this study was to analyze the correlation between radiomorphometric indexes of bone density through panoramic radiographic images, bone quality profile using the Cone-Beam Computed Tomography (CBCT) and the OsiriX imaging software, Resonance Frequency Analysis (RFA) and insertion torque implant. One hundred and sixty implants were evaluated in 72 individuals with a mean age of 55.5 (± 10.5) years. In the panoramic radiographic images, the IM, IPM and ICM indexes were assessed. For the cone beam computed tomography, the analyses included pixel values, thickness of cortical bone crest, as well as the primary stability through the insertion torque and resonance frequency. The results were analyzed by Spearman correlation coefficient for p <= 0.01. The values between insertion torque and pixel were (0.330), the insertion torque and cortical thickness of the alveolar crest were (0.339), for torque insertion and ISQ vestibule-lingual (0.193), and for pixel values and cortical thickness of the alveolar crest (0.377). Considering both directions bucco-lingual and mesial-distal ISQ the values were (0.674), the bucco-lingual ISQ and cortical thickness of the alveolar ridge were (0.270); the radiomorphometric indexes were correlated between themselves. Values of p <= 0.05 were obtained between insertion torque and mesio-distal ISQ (0.131), as well as the ISQ vestibule-lingual and the pixel values (0.156) and also mesial-distal ISQ and left IPMI (0.149) and mesial-distal ISQ and left IPMS (0.145). There is a correlation between the CBCT, the insertion torque and RFA in the evaluation of bone quality. CBCT scans can be used prior to surgery, in order to assess bone quality and quantity, considering the correlations obtained in this study.

Page generated in 0.0511 seconds