• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 141
  • 116
  • 43
  • 23
  • 18
  • 14
  • 10
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • Tagged with
  • 431
  • 114
  • 108
  • 95
  • 43
  • 42
  • 41
  • 40
  • 38
  • 28
  • 23
  • 22
  • 22
  • 21
  • 21
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
141

Avaliação da infiltração apical, pós tratamento de canais radiculares, utilizando 4 diferentes técnicas combinadas de instrumentação rotatória e obturação por termoplastificação. Estudo in vitro

Cervi, Devanir de Araújo [UNESP] 28 February 2002 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2002-02-28Bitstream added on 2014-06-13T19:52:10Z : No. of bitstreams: 1 cervi_da_me_arafo.pdf: 2178427 bytes, checksum: c6ea8e8823b6b51fa82888cf17798887 (MD5) / Foram utilizados 115 dentes pré molares inferiores de humanos, que foram divididos em 5 grupos de 16 dentes cada; sendo 5 grupos com 5 dentes cada, utilizados como controle positivo e, 5 grupos de 2 dentes como controle negativo. Em todos os dentes após a abertura coronária, foi realizado o desbridamento foraminal com uma lima tipo Kerr no 15 até 1mm além do forame apical e o preparo biomecânico a 1mm aquém comprimento real do dente. Foram utilizados para a instrumentação dos canais radiculares, os sistemas de limas rotatórias de níquel titânio ProFile 0.4/.06 e Quantec, e a técnica Clássica Modificada; sendo o batente apical preparado até a lima 45 de cada técnica de instrumentação. A cada troca de lima, foi utilizado o hipoclorito de sódio à 1% como solução irrigadora. Posteriormente os dentes foram obturados pelos sistemas de guta-percha termoplastificada Thermafil, Microseal e pela técnica da Condensação Lateral Ativa; utilizando como cimento obturador; AH Plus. Após as obturações os dentes foram impermeabilizados com esmalte de unha, exceto, o 1mm ao redor do forame apical; imersos no corante de azul de metileno à 2% sob vácuo e fraturados de maneira a serem obtidas duas hemi-partes. A penetração do corante foi medida com auxílio de um perfilômetro, e os dados, após análise estatística mostraram que, o grupo de dentes instrumentados pelo sistema ProFile 0.4/.06 e obturados com o sistema Thermafil, apresentaram menor infiltração apical, quando comparado com os demais grupos. / It was evaluated 115 mandibular premolars of humans, that were divided in 5 groups of 16 teeth each; 5 groups with 5 teeth each, used as positive control and 5 groups of 2 teeth as negative control. After coronary acess, the apical patency was accomplished with a file type Kerr no 15 up to 1mm after the apical foramen and prepared to 1mm short of working length. Instrumentation wasdone, using ProFile 0,04 and 0,06 and Quantec, stotary files and the Modified Classic technique; The apical preparation used a file 45 as memory file. After each file change, sodium hypochlorite was used at 1% as irrigation solution. The teeth were filled using systems of thermoplasticized gutta-percha Thermafil, Microseal and the technique of the Active Lateral Condensation. The sealer used was the AH Plus root canal sealer. After obturation the teeth were waterproof with fingernail enamel, except, the 1mm short of the apical foramen; immerged in the coloring of methylene blue at 2% under vacuum and fractured in a way where it was obtained two hemi-parts. The penetration of the coloring was measured with aid of a Nikon Profile Projector, and the data, after statistical analysis showed that, the group of teeth under the system ProFile 0,04 and 0,06 and filled with the system Thermafil, presented lower leakage apical, when compared with other groups.
142

Avaliação da qualidade da obturação de canais radiculares e da confiabilidade do modelo de penetração de glicose /

Souza, Erick Miranda. January 2008 (has links)
Orientador: Idomeo Bonetti Filho / Banca: Márcia Carneiro Valera / Banca: Ivaldo Gomes de Moraes / Banca: Renato de Toledo Leonardo / Banca: Mário Tanomaru Filho / Resumo: Diferentes técnicas de compactação da guta-percha (GP) e cimentos oburadores podem alterar a qualidade final da obturação do canal radicular. Recentemente foi introduzido um novo modelo de análise da qualidade de obturações endodônticas baseado na mensuração da concentração da glicose que passa pela falha na obturação. Este trabalho é composto por três capítulos cujos objetivos foram: a) determinar os efeitos de variações na técnica de condensação lateral (LC) e da área do canal na qualidade da obturação; b) verificar se diferentes materiais obturadores alteram a concentração do traçador utilizado no modelo de penetração de glicose, e; c) determinar se são similares os resultados de infiltração dos mesmos espécimes avaliados pelos modelos de penetração de glicose e transporte de fluidos. No primeiro estudo sessenta caninos humanos foram instrumentados e divididos em três grupos obturados por diferentes técnicas de LC e cimento AH Plus. Uma nova técnica usando uma seqüencia de espaçadores antes da colocação de um cone acessório foi comparada com duas técnicas comumente utilizadas. As raízes obturadas foram seccionadas nos níveis 3 mm e 6 mm a partir do ápice e as secções fotografadas. Usando um software de análise de imagens, as áreas do canal e de GP em cada nível foram mensuradas e a porcentagem de área obturada por guta-percha (PGP) foi calculada. Análise múltipla de variância foi utilizada para verificar as variáveis influenciando a PGP. Teste de regressão linear foi utilizado para verificar a influência da área do canal na PGP em cada nível de secção. Em ambas as secções o canal mais largo foi 2-3 vezes maior que o menos largo. Quanto maior a área do canal, menor a PGP nos níveis 6 mm (r2=0,154, P=0,02) e 3 mm (r2=0,119, P=0,007). A PGP no nível 3 mm foi menor que a 6 mm (P=0.003). A nova técnica atingiu maior PGP que as demais em ambos os níveis (P<0.05). / Abstract: Different gutta-percha (GP) compaction techniques and root canal sealers may affect the final quality of the root canal filling. Recently, it was discussed a new method for evaluation of the quality of root fillings based on measuring the concentration of the glucose that penetrates through voids in the obturation. This work is divided in 3 chapters aiming to: a) determine the effects of different techniques and canal area on the quality of laterally compacted root fillings; b) verify whether different filling materials react with the tracer used in the glucose penetration model, and; c) determine whether leakage results of the same specimens measured by the glucose penetration and fluid transport are comparable. In the first study sixty extracted canines were instrumented to the same size and equally divided in three groups filled with laterally compacted GP cones and AH Plus sealer using different techniques. A new technique with use of a sequence of spreaders prior to the accessory cone placement was compared to two commonly used techniques. The filled roots were horizontally sectioned at 3 mm and 6 mm from the apex and micro-photographs of the cross-sections were taken. Using an image-analysis software, the canal and GP areas at each level were measured. The percentage of gutta-percha filled canal area (PGP) was calculated. A Multivariate analysis was used to account for the variables influencing the PGP. Linear regression test was used to verify the influence of canal area on PGP. At each level the largest canal was 2-3 times larger than the smallest. The larger the canal area, the lower the PGP at 6 mm level (r2= 0.154, P=0.02) and at 3 mm level (r2=0.119, P=0.007). The PGP at 3 mm was lower than at 6 mm (P=0.003). The new technique achieved higher PGP than other techniques (P=0.00002). / Doutor
143

Avaliação de solubilidade e desintegração, alteração dimensional e resistência à compressão de cimentos endodônticos /

Guinesi, Adriana Simionatto. January 2008 (has links)
Resumo: O propósito do presente estudo foi avaliar os cimentos endodônticos Acroseal, AH Plus, Epiphany e Polifil (cimento endodôntico experimental), no que se refere às propriedades de solubilidade e desintegração, alteração dimensional e resistência à compressão. Os testes seguiram a Norma ISO 6876-2, de 2001 e ISO 9917-1, de 2003. Nos testes de solubilidade e desintegração foram utilizados moldes de teflon (4mm de espessura, 12mm de diâmetro interno e 2mm de parede) preenchidos com cimentos endodônticos e contendo perfuração com fio de nylon para suspensão das amostras. Os espécimes foram levados à estufa até a presa dos materiais. Em seguida, as amostras hidratadas e desidratadas tiveram sua massa mensurada imediatamente após sua retirada da estufa, e após períodos de 24h, 48h, 72h, 7, 14, 30, 60 e 90 dias. A solubilidade dos cimentos endodônticos foi identificada pela alteração da massa de cada amostra, expressa como o percentual de massa perdida em comparação à massa inicial. A desintegração foi identificada visualmente, pela observação de resíduos nos recipientes e pela turbidez da água destilada. Nos testes de alteração dimensional e resistência à compressão foram utilizados moldes de teflon (12mm de espessura e 6mm de diâmetro). Os moldes foram preenchidos com cimentos endodônticos e levados à estufa até a tomada de presa, então foram removidos dos moldes e, para os testes de alteração dimensional, suas dimensões foram medidas, no sentido longitudinal, com paquímetro digital, imediatamente após sua retirada da estufa e após períodos de 24, 48 e 72 horas, 7, 14, 30, 60 e 90 dias de armazenamento. A alteração dimensional foi identificada como a percentagem de alteração volumétrica no final de cada período, em comparação ao período inicial. / Abstract: Considering all the steps of the endodontic therapy, their success depend on the root canals sealing when the professional uses an endodontic sealer that gathers physical, chemical and biological properties. The aim of this study was to evaluate the endodontic sealers: Acroseal, AH Plus, Epiphany and a castor-oil based experimental sealer (Polifil) concerning the properties of solubility and disintegration, dimensional change and compressive strength. All of these tests were supposed to follow the ISO Specification 6876-2, 2001 and ISO Specification 9917-1, 2003. To perform the solubility and disintegration tests teflon rings (4 mm thickness, 12 mm of internal diameter, and 2 mm height) filled with the endodôntico sealers were used, containing perforations that allow a nylon wire passing through it, in order to get the specimens raised up. They were storaged in the oven under 37º C up to the setting time. The specimens were hydrated and dehydrated to be weighted for 24h, 48h, 72h, 7, 14, 30, 60 and 90 days. The solubility of the endodontic sealers was identified as a percentage obtained through the difference between the last measure of weight and the initial one. The disintegration were visually identified by observating the residues and the water's whirlwind. Teflon moulds (12 mm thickness and 6mm diameter) were used in dimensional change and compressive strength tests. They were filled with the endodontic sealers and storaged in the oven under 37º C up to the setting time. Afterwards, the moulds were removed and then, for the dimensional change test, they were measured under the longitudinal position with digital pachymeter for 24h, 48h, 72h, 7, 14, 30, 60 and 90 days. The dimensional change was identified as a percentage of the volumetrical change gotten in each time, compared with the first specimen. / Orientador: Idomeo Bonetti Filho / Coorientador: Luís Geraldo Vaz / Banca: Yara Teresinha Corrêa Silva Souza / Banca: Roberto Miranda Esberard / Mestre
144

Sistema adesivo na obturação de canais radiculares : biocompatibilidade e infiltração coronária (reparação apical e periapical em dentes de cães) /

Lima, Regina Karla de Pontes. January 2006 (has links)
Orientador: Mario Roberto Leonardo / Banca: Lea Assed Bezerra da Silva / Banca: Antonio Carlos Bombarda / Resumo: O objetivo deste estudo foi o de avaliar, in vivo, a biocompatibilidade e a influência da infiltração, no sentido coroa/ápice, na reparação dos tecidos apicais e periapicais pós-tratamento endodôntico, utilizando dois diferentes materiais obturadores: o cimento Sealapex e um sistema resinoso de obturação de canal radicular denominado de sistema Epiphany/Resilon. Os resultados mostraram que o sistema Epiphany/Resilon apresentou resposta tecidual apical e periapical melhor que o cimento Sealapex, independente da presença ou não de restauração coronária, em todos os aspectos estudados. O sistema Epiphany/Resilon com restauração coronária apresentou melhores resultados que o mesmo sistema sem restauração coronária. O cimento Sealapex sofreu influência da infiltração coronária, apresentando, em todas as variáveis estudadas, os piores resultados, quando exposto ao meio bucal. / Abstract: The objective of this study was to evaluate, in vivo, the biocompatibility and the leakage influence, in the crown-apex direction, in the endodontic post-treatment repairing of apical and periapical tissues, using two different filling materials: Sealapex sealer and a resinous cement of root canal filling - Epiphany/Resilon. The results showed that Epiphany/Resilon system presented apical and periapical tissue response better than Sealapex independent of presence or no of the coronary restoration, in all studied aspects. Epiphany/Resilon system, with coronary restoration presented better results than of the same system without coronary restoration. Sealapex was influenced by the coronary exposition to oral environment, presenting the worst results in all studied variables. / Mestre
145

Preenchimento automático de formulários na web oculta / Automatically filling in hiddenweb forms

Kantorski, Gustavo Zanini January 2014 (has links)
Muitas informações disponíveis na Web estão armazenadas em bancos de dados on-line e são acessíveis somente após um usuário enviar uma consulta por meio de uma interface de busca. Essas informações estão localizadas em uma parte da Web conhecida como Web Oculta ou Web Profunda e, geralmente, são inacessíveis por máquinas de busca tradicionais. Uma vez que a forma de acessar os dados na Web Oculta se dá por intermédio de submissões de consultas, muitos trabalhos têm focado em como preencher automaticamente campos de formulários. Esta tese apresenta uma metodologia para o preenchimento de formulários na Web Oculta. Além disso, descreve uma categorização das técnicas de preenchimento de formulários existentes no estado da arte de coleta na Web Oculta, produzindo uma análise comparativa entre elas. A solução proposta descreve um método automático para seleção de valores para campos de formulários combinando heurísticas e técnicas de aprendizagem de máquina. Experimentos foram realizados em formulários reais da Web, de vários domínios, e os resultados indicam que a abordagem proposta apresenta desempenho comparável aos obtidos pelas técnicas do estado da arte, sendo inclusive significativamente diferente com base em avaliação estatística. / A large portion of the information on the Web is stored inside online databases. Such information is accessible only after the users submit a query through a search interface. TheWeb portion in which that information is located is called HiddenWeb or DeepWeb, and generally this part is inaccessible by traditional search engines crawlers. Since the only way to access the Hidden Web pages is through the query submissions, many works have focused on how to fill in form fields automatically, aiming at enhancing the amount of distinct information hidden behind Web forms. This thesis presents an automatic solution to value selection for fields in Web forms. The solution combines heuristics and machine learning techniques for improving the selection of values. Furthermore, this proposal also describes a categorization of form filling techniques and a comparative analysis between works in the state of the art. Experiments were conducted on real Web sites and the results indicated that our approach significantly outperforms a baseline method in terms of coverage without additional computational cost.
146

Síntese de vistas em depht-image-based rendering (DIBR) / View synthesis with depth-image-based rendering (DIBR)

Oliveira, Adriano Quilião de January 2016 (has links)
Esta dissertação investiga soluções para o problema genérico de geração de vistas sintéticas a partir de um conjunto de imagens utilizando a abordagem Depth-Image-Based Rendering. Essa abordagem utiliza um formato compacto para a representação de imagens 3D, composto basicamente por duas imagens, uma colorida para a vista de referência e outra em tons de cinza com a correspondência de disparidade para cada pixel. Soluções para esse problema beneficiam aplicações como Free Viewpoint Television. O maior desafio é o preenchimento de regiões sem informação de projeção considerando o novo ponto de vista, genericamente denominados holes, além de outros artefatos como cracks e ghosts que ocorrem por oclusões e erros no mapa de disparidade. Nesta dissertação apresentamos técnicas para remoção e tratamento de cada uma das classes de potenciais artefatos. O conjunto de métodos propostos apresenta melhores resultados quando comparado com o atual estado da arte em geração de vistas sintéticas com o modelo DIBR para o conjunto de dados Middlebury, considerando-se as métricas SSIM e PSNR. / This dissertation investigates solutions to the general problem of generating synthetic views from a set of images using the Depth-Image-Based Rendering approach. This approach uses a compact format for the 3D image representation, composed basically of two images, one color image for the reference view and other grayscale image with the disparity information available for each pixel. Solutions to this problem benefit applications such as Free Viewpoint Television. The biggest challenge is filling in regions without projection information considering the new viewpoint, usually called holes, and other artifacts such as cracks and ghosts that occur due to occlusions and errors in the disparity map. In this dissertation we present techniques for removal and treatment of each of these classes of potential artifacts. The set of proposed methods shows improved results when compared to the current state of the art generation of synthetic views using the DIBR model applied to the Middlebury dataset, considering the SSIM and PSNR metrics.
147

Bridging the Gap Between Space-Filling and Optimal Designs

January 2013 (has links)
abstract: This dissertation explores different methodologies for combining two popular design paradigms in the field of computer experiments. Space-filling designs are commonly used in order to ensure that there is good coverage of the design space, but they may not result in good properties when it comes to model fitting. Optimal designs traditionally perform very well in terms of model fitting, particularly when a polynomial is intended, but can result in problematic replication in the case of insignificant factors. By bringing these two design types together, positive properties of each can be retained while mitigating potential weaknesses. Hybrid space-filling designs, generated as Latin hypercubes augmented with I-optimal points, are compared to designs of each contributing component. A second design type called a bridge design is also evaluated, which further integrates the disparate design types. Bridge designs are the result of a Latin hypercube undergoing coordinate exchange to reach constrained D-optimality, ensuring that there is zero replication of factors in any one-dimensional projection. Lastly, bridge designs were augmented with I-optimal points with two goals in mind. Augmentation with candidate points generated assuming the same underlying analysis model serves to reduce the prediction variance without greatly compromising the space-filling property of the design, while augmentation with candidate points generated assuming a different underlying analysis model can greatly reduce the impact of model misspecification during the design phase. Each of these composite designs are compared to pure space-filling and optimal designs. They typically out-perform pure space-filling designs in terms of prediction variance and alphabetic efficiency, while maintaining comparability with pure optimal designs at small sample size. This justifies them as excellent candidates for initial experimentation. / Dissertation/Thesis / Ph.D. Industrial Engineering 2013
148

Análise de desempenho microbiológico de uma linha de processamento piloto de caldo de cana / Sugarcane juice processed in a pilot plant: the microbiological evaluation

Carine Oliveira da Silva 14 August 2015 (has links)
O presente estudo foi desenvolvido com o objetivo de avaliar o desempenho microbiológico de uma linha de processamento e envase asséptico de caldo de cana acidificado. Para este fim foram identificados pontos críticos de controle em uma planta piloto instalada no Departamento de Engenharia de Alimentos da Faculdade de Zootecnia e Engenharia de Alimentos da Universidade de São Paulo, no campus de Pirassununga/SP. Inicialmente o caldo de cana foi extraído e acidificado com ácido cítrico a um valor de pH equivalente a 4,3. A bebida acidificada foi pasteurizada a 95 °C / 30 s, resfriada a 10 °C e acondicionada assepticamente em garrafas plásticas seladas por indução. O envase do produto foi conduzido em uma cabina de fluxo de ar unidirecional ISO classe 5. As garrafas foram descontaminadas por aspersão de ácido peracético a 0,05% (v/v), por 20 s a 45 ºC. Os selos e as tampas foram esterilizados a 121 ºC / 15 min. Realizaram-se três processamentos de caldo de cana, em datas distintas, tendo sido caracterizada a matéria-prima e avaliados a qualidade microbiológica do caldo recém-extraído; a água de enxágue final da linha de processamento e envase, após a sua desinfecção com solução de ácido peracético (0,1% v/v) a 50 ºC durante 40 min; a embalagem e o produto final. Testes de escala hedônica de 7 pontos foram aplicados para avaliar a aparência, o aroma e o sabor da bebida processada. Os valores médios de pH, de acidez titulável e de sólidos solúveis determinados na matéria-prima foram equivalentes a 5,1; 0,061%(m/v) e 22,3 ºBrix, respectivamente. As médias das contagens de micro-organismos mesófilos aeróbios totais e de bolores e leveduras no caldo in natura foram equivalentes a (6,26 e 5,20) logUFC/mL, respectivamente. As médias das contagens na água de enxágue final (pasteurizada) da linha de processamento e envase foram inferiores a 1 UFC/mL. As contagens de mesófilos, de bolores e leveduras nas embalagens foram igualmente inferiores a 1 UFC/embalagem. As médias das contagens de mesófilos aeróbios e de bolores e leveduras na bebida acidificada e pasteurizada foram equivalentes a (2,63 e &lt; 1) logUFC/mL, respectivamente. As médias de notas obtidas nos testes de escala hedônica de 7 pontos variaram entre 5,8 e 6,1; demonstrando a elevada aceitação do caldo de cana acidificado. Concluiu-se que a planta de processamento avaliada mostrou-se apta ao processamento de caldo de cana acidificado, estocado sob refrigeração. / This study was carried out to evaluate the microbiological performance of a pilot plant designed for acidified sugarcane juice processing. For this purpose, critical control points in a pilot plant were identified. The juice was extracted in a stainless steel electric cylinder mill and then acidified with citric acid until attaining the pH of 4.3. Next, it was pasteurized in a plate heat exchanger at 95 ºC/30 s and then cooled to 10 ºC before being filled into a plastic bottle and induction sealed. Product\'s filling was performed in an ISO class 5 unidirectional air-flow cabin. Bottles were decontaminated by 0.05% peracetic acid (PAA) spray, at 45 ºC for 20 s. Seals and caps were sterilized at 121 ºC/15 min. Three batches of acidified sugarcane juice were carried out. The qualities of the raw material, rinse water of the processing and filling line (after sanitation with 0.1% PAA at 50 ºC for 40 min), packaging and end product, were all microbiologically evaluated. Seven-point hedonic scale tests were used to evaluate the sensory acceptance of the product. The mean values of pH, titratable acidity and soluble solids content determined in raw sugarcane juice were 5.1, 0.061%(w/w) and 22.3 ºC, respectively. The total aerobic mesophilic and the molds and yeasts mean counts in natural fresh sugarcane juice were (6.26 and 5.20) logCFU/mL, respectively. The mesophilic and the molds and yeasts mean counts taken, in both rinse water samples of the processing line and the bottles, were lower than 1 logCFU/mL. The mesophilic and the molds and yeasts mean counts in acidified and pasteurized sugarcane juice were (2.63 and lower than 1) logCFU/mL, respectively. A beverage with a high sensory acceptance with average scores ranging from 5.8 to 6.1 was achieved. The findings indicated that the procedures that were evaluated met standards for acidified sugarcane juice to be produced then stored under refrigeration.
149

Evaluation of Push-Out Bond Strengths of Three Root Canal Sealers / AvaliaÃÃo da forÃa de adesÃo de trÃs cimentos endodÃnticos pelo mÃtodo do push-out

Walter Cavalcante SÃ Neto 31 July 2012 (has links)
nÃo hà / The main aim of endodontic therapy is the cleaning and shaping of the root canal and the complete filling of the entire root canal system. Adhesion is defined as the atomic or molecular attraction between two surfaces that touch, caused by the interfacial force of attraction between the molecules or atoms of both materials. The adhesion can be chemical, mechanical or a combination of both. The perfect adhesion of the filling to the canal walls is a constant search through the improvement and introduction of new materials used in this phase of treatment, with emphasis on the sealer that promotes the union of the solid part of the filling, gutta-percha, to the walls of the root canal. This study aimed to evaluate the bond strength of three root canal sealers by the push-out test, that is quite reliable in view of the accuracy and reproducibility of results. Thirty human upper canines teeth were selected and sectioned at the cementoenamel junction to remove the crown and 2 mm from the apex. All canals were enlarged with Gates-Glidden drills #1-5 and finished the preparation with Peeso drill #6. Between every drill exchange, 1 ml of 2.5% sodium hypochlorite was used as irrigating solution. The roots were sectioned in 1 mm slices and filled according to the root canal sealer, subdividing each group according to the root third (n=25). They were then filled with the sealer as follow: Group 1, AH Plus, Group 2, MTA Fillapex and Group 3 Pulp Canal Sealer. The results showed statistically significant superiority of the AH Plus compared to the other two sealers and Pulp Canal Sealer in relation to the MTA Fillapex. Regarding the root thirds, only the Pulp Canal SealerÂs group showed statistically significant differences, with superiority of the apical third compared to cervical and middle thirds. It is concluded that AH Plus showed the best values of bond strength, regardless of the root third. / Os principais objetivos do tratamento endodÃntico sÃo a limpeza, a modelagem do canal radicular e a completa obturaÃÃo de todo o sistema de canais radiculares. Uma das propriedades exigidas do material obturador à a adesÃo, que à definida como a atraÃÃo molecular ou atÃmica entre duas superfÃcies que se tocam, causada pela forÃa de atraÃÃo interfacial existente entre as molÃculas ou Ãtomos de dois materiais. A adesÃo pode ser quÃmica, mecÃnica ou a combinaÃÃo de ambas. A perfeita adesÃo da obturaÃÃo Ãs paredes do canal à uma busca constante atravÃs do aprimoramento e lanÃamento de novos materiais utilizados nessa fase do tratamento, com Ãnfase no cimento endodÃntico, responsÃvel pela uniÃo da parte sÃlida da obturaÃÃo, a guta percha, Ãs paredes do canal radicular. Este estudo teve como objetivo avaliar a forÃa de adesÃo de trÃs cimentos endodÃnticos atravÃs do teste de push-out, que à um teste bastante confiÃvel, tendo em vista a precisÃo dos resultados e sua reprodutibilidade. Trinta caninos superiores humanos extraÃdos foram selecionados e seccionados na junÃÃo cemento-esmalte, descartando-se a coroa e removendo-se 2mm do Ãpice radicular. Em seguida, os canais radiculares foram preparados com brocas de Gates-Glidden #1 a 5 e finalizados com a broca de Peeso #6, gerando um preparo do canal radicular de forma cilÃndrica e com 1,5 mm de diÃmetro. Logo apÃs, as raÃzes foram seccionadas transversalmente em fatias de 1mm de altura, sendo logo apÃs divididas em 3 grupos de acordo com o cimento utilizado e 3 sub grupos, de acordo com o terÃo radicular (n=25). Os espÃcimes foram entÃo preenchidos com o cimento da seguinte forma: Grupo 1, cimento AH Plus, Grupo 2, cimento MTA Fillapex e Grupo 3, cimento Pulp Canal Sealer. Os resultados mostraram superioridade com diferenÃa estatisticamente significante do cimento AH Plus em relaÃÃo aos outros dois cimentos e do Pulp Canal Sealer em relaÃÃo ao MTA Fillapex. Em relaÃÃo aos terÃos radiculares, somente no grupo do Pulp Canal Sealer foram encontradas diferenÃas estatisticamente significantes, com superioridade do terÃo apical em relaÃÃo aos terÃos cervical e mÃdio. Conclui-se que o cimento AH Plus apresentou os melhores valores de forÃa de adesÃo, independente do terÃo radicular.
150

"Avaliação da vedação apical proporcionada por três materiais retroobturadores" / Evaluation of sealing ability of three root-end filling materials

Claudia Panzani 14 December 2005 (has links)
A cirurgia parendodôntica é um recurso utilizado para solucionar casos em que a terapia endodôntica não obteve sucesso, ou ainda na impossibilidade da sua realização. A escolha de um material retroobturador adequado pode contribuir positivamente para o reparo tecidual. Este estudo teve como objetivo avaliar a capacidade seladora de três materiais usados para retroobturação, em dois tempos diferentes, tendo como marcador o corante Rodamina B a 0,2%. Sessenta e seis dentes tiveram as suas coroas seccionadas, os canais preparados com limas manuais e obturados com cimento e guta-percha. Seccionaram-se dois milímetros da porção apical e cavidades retrógradas foram preparadas com pontas de ultra-som lisas; dividindo-se então, em 3 grupos experimentais que receberam os seguintes materiais: MTA Ângelus ® , Real Seal ® e um material experimental desenvolvido pelo IPEN-USP (Instituto de Pesquisas Energéticas e Nucleares da Universidade de São Paulo). Dez elementos de cada grupo foram imersos em soro fisiológico durante 72h a 37°C, antes de serem impermeabilizados e colocados no corante por 24h (grupos I A, II A e III A). Os demais permaneceram 60 dias em soro fisiológico para depois serem impermeabilizados e colocados no marcador (grupos I B, II B e III B). O controle positivo consistiu de 3 espécimes, que não tiveram as cavidades retroobturadas. Outros três espécimes serviram como controle negativo, cada um foi retroobturado com um dos materiais em estudo e foram totalmente impermeabilizados antes de serem imersos no corante. Após o tempo de imersão no corante, todos os espécimes foram lavados, e em seguida, clivados ongitudinalmente no sentido mésio-distal. As superfícies foram avaliadas em lupa estereoscópica com aumento de 20X e fotografadas. A infiltração linear foi medida com auxílio de uma lente reticulada e régua milimetrada. Os resultados foram submetidos aos testes estatísticos de Kruskal-Wallis e verificou-se que não houve diferença entre os grupos do MTA Ângelus ® e do Real Seal ® , sendo que a maior infiltração do corante ocorreu na interface dentina-material experimental, com diferença estatisticamente significante ao nível de 1% (a=0,01). Fazendo a análise estatística de Mann-Whitney entre os grupos com o mesmo material, verificou-se que o tempo de permanência em umidade até 60 dias não influenciou na vedação dos materiais retroobturadores. / Apical surgery is a resource that is used to solve cases in which endodontic therapy was either unsuccessful or could not be done. Choice of root-end filling material contributes for successful. The purpose of this study was to evaluate the sealing ability of three materials used for root-end filling, using 0.2% Rhodamine B. Sixty-six teeth had their crowns removed, and their canals were cleaned and shaped with manual files, and filled with cement and gutta-percha. Two millimeters of the apical portion were sectioned and root-end cavities were prepared in all specimens with smooth ultrasonic tips. Three groups were formed to receive the following materials: MTA Ângelus ® , Real Seal ® , and an experimental material developed by the IPEN-USP (Institute of Energetic and Nuclear Research from São Paulo University). Ten specimens from each group were immersed in a physiological saline solution for 72h at 37°C, before being waterproofed and put in the colorant for 24 h (groups I A, II A, and III A). The others remained in physiological saline solution for 60 days and were then waterproofed and put in the marker (groups I B, II B, and III B). The positive control consisted of three specimens that did not have their cavities root-end filled. Another three specimens served as a negative control, each being root-end filled with one of the materials being studied, and they were totally waterproofed before being immersed in Rhodamine B. After the time of immersion in the colorant, all of the Speci mens were washed and then cleaved longitudinally in the mesio-distal direction. The surfaces were evaluated under a stereoscopic magnifying glass at 20X magnification and photographed. The linear infiltration was measured with a micro metered lens and millimeter rule . The results were submitted to the Kruskal-Wallis statistical tests and it was noticed that there was no difference between the MTA Ângelus ® and Real Seal ® groups. The experimental material presents the most colorant microleakage, with a statistically significant difference (a=0.01). The Mann-Whitney statistical analysis performed in the groups with the same material showed that the period of time the specimen remained exposed to moisture - up to 60 days - did not impact the materials’ sealing capacity.

Page generated in 0.0947 seconds