11

Avaliação radiográfica, histomorfométrica e de função de vôo após fixação de osteotomias distais de úmero em pombas (Columba livia), com modelo inédito de fixador externo articulado. Estudo comparativo de fixador transarticular dinâmico e estático / Radiographic histomorphometric and of flight function evaluations after distal humeral osteotomies in pigeons (Columba livia), with inedit articulated external fixator. Comparative study of dynamic and static transarticular fixators

Vanessa Couto de Magalhães Ferraz 26 September 2008 (has links)
O tratamento de fraturas umerais distais em aves impõe grande dificuldade, devido a córtices muito finas dos ossos A artrodese com fixador externo da articulação úmero-rádio-ulnar é inviável para aves que se pretende reintroduzir ao meio ambiente. Doze animais foram divididos em dois grupos: cirurgias bilaterais com anquilose de uma asa (asa estática) e manutenção da articulação da outra (asa dinâmica) (grupo 1), e cirurgia unilateral, com manutenção da função da articulação (asa dinâmica), sendo a outra controle (asa intacta) (grupo 2). Foram feitas avaliações clínicas, radiológicas, morfológicas do osso, histomorfométricas (de ambos os grupos) e de capacidade de vôo (grupo 2). A 6 semanas, todos os animais apresentavam fraturas consolidadas, com excessão de dois animais do grupo 1, que somente apresentaram consolidação das asas dinâmicas às 9 semanas e das estáticas às 12 semanas. Todos os animais do grupo 2 apresentaram capacidade de vôo adequada, antes de 13 semanas após a cirurgia. No grupo 1 o úmero da asa dinâmica representava 99,1% do comprimento do da asa estática, e no grupo 2, estes eram 99,5% em relação à asa intacta. A amplitude da asa, no grupo 2, demonstrou que a relação da asa dinâmica/intacta foi de 93%, e no grupo 1 a relação asa dinâmica/estática foi de 105%. O volume do osso intacto foi de aproximadamente 29% da área estudada, enquanto o da asa estática foi de 19% e das asas dinâmicas, de 22%. Houve diferença entre o número de osteoblástos das asas intactas e dinâmicas, porém não houve diferença entre as asas estáticas e intactas e entre as dinâmicas e as estáticas, e também não houve diferença do número de osteoclástos entre nenhum tipo de asa. A razão da superfície óssea pelo volume ósseo indica a quantidade de áreas de reabsorção. Não houve diferença entre as asas estática e dinâmica, porém houve diferença entre estas e os controles. O método proposto de técnica para fixação de fraturas umerais distais, sem a anquilose da articulação úmero-rádio-ulnar, demonstrou ser efetivo em manter o comprimento ósseo, a amplitude da asa e assim, garantindo a capacidade de vôo das aves tratadas, além de demonstrar ser equivalente histológicamente à técnica tradicional e mais estável de anquilose da articulação, para este tipo de fratura, e até mesmo, no período estudado, ser equivalente ao osso são, sendo um método adequado para a reparação de fraturas distais de úmero em aves quando se pretende a reabilitação destes animais. / The treatment of humeral distal fractures in birds is very difficult, because these bones are very brittle. Ankylosis of the humeral-radio-ulnar joint with an external fixator is unviable for birds intended for re-habilitation and reintroduction. Twelve animals were used and they were divided in two groups: bilateral surgeries, with ankylosis of one wing (static wing) and maintenance of the joint function of the other wing (dynamic wing) (group 1), and unilateral surgery, with maintenance of the joint function of the wing (dynamic wing), and the other was used as control group (intact wing) (group 2). Clinical, radiographic, morphologic and histomorphometric evaluations of the wings and bones (of both groups) and of evaluations of flight capacity (in group 2) were made. At 6 weeks, all animals had healed fractures, except two animals in group 1, that only presented consolidation of the dynamic wing at 9 weeks and the static wings at 12 weeks. All animals in group 2 were capable of flying before 13 weeks after surgery. In group 1, the humerus of the dynamic wing was 99.1% the length of that of the static wing, and in group 2, these were 99.5% compared to the intact wing. Wing amplitude, in group 2, showed a dynamic/ intact ratio of 93%, and in group 1 the dynamic/ static wing ratio was 105%. The volume of the intact bone was approximately 29% of the studied area, while in the static wing it was of 19% and in the dynamic wing, 22%. There was a difference in the number of osteoblasts of the intact and dynamic wings, but there was no difference between static and intact, and between dynamic and static wings, and also, there was no difference in the numbers of osteoclasts between any wings. The bone surface/ volume ratio indicates the amount of resorption areas. There was no significant difference between static and dynamic wings, but there was a difference between static and intact wings. The proposed method of distal humeral fracture fixation technique, without ankylosis of the humerus-radius-ulna joint, demonstrated being effective in keeping bone length, wing amplitude e therefore, guaranteeing flight capacity of the birds treated, as well as being histologically equivalent to the tradicional, more stable, joint ankylosis technique, for thise kind of fracture, and even, for the studied period, being equivalent to healthy bone, being an adequate method for fracture repair for this kind of fracture in birds, when one intends rehabilitation of these animals.
12

Modificações do fixador externo para osteossíntese Umeral em pombos domésticos (Columba livia) / Two types of external fixators to correct humeral Fracture in domestic pigeons (Columba livia)

Dalmolin, Fabíola 06 February 2006 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim of this study was to evaluate two types of external fixators induced to correct humeral fracture in eighteen domestic pigeons. The reduction of an diaphyseal humeral fracture was made with an intramedulary pin associated to another perpendicular one inserted into the distal segment (Group A - GA); in the other group (Group B - GB), an additional pin was used in the proximal fragment. All the pigeons were evaluated clinically and radiographically up to 60 days post surgery, except four of each group which were submitted to euthanasia at 15, 22 29 and 36 days for the macro and microscope exams. The flight test was successful in all pigeons. The bone calus was radiografically visible only in the GA; the mean time and the standard deviation for flight was 32,25 ± 6,5 days for the GA and 39,8 ± 3,83 for the GB. The mean time and standard deviation for fracture healing was 36 ± 0 days in the GA and 34 ± 3,4 in the GB. The anatomy pathological studies revealed that the bone consolidation process in the GB ocurred earlier than in the GA. The two types of external fixator evaluated were efficient to stabilized the fracture site allowing complete consolidation and return to function. The use of the external fixator with two perpendicular pins provide more stability at the fracture site although it s necessary more time for the surgery. / Este trabalho objetivou avaliar dois tipos de modificações no fixador externo para correção de fratura umeral em 18 pombos domésticos. Após realização de fratura umeral diafisária reduziu-se essa com um pino intramedular associado a outro perpendicular inserido no segmento distal (Grupo A - GA); no Grupo B (GB) utilizou-se um pino adicional no fragmento proximal. Todas as aves foram avaliadas clinica e radiograficamente até 60 dias de pós-operatório, exceto quatro de cada grupo que, respectivamente, aos 15, 22, 29 e 36 dias foram submetidas à eutanásia para exame macro e microscópico. Quanto ao vôo, todos os animais avaliados obtiveram êxito, sendo o tempo médio e o desvio padrão de 32,25 ± 6,5 dias no GA e de 39,8 ± 3,83 dias no GB. Observou-se presença de calo ósseo ao exame radiográfico somente nos animais do GA. O tempo médio e o desvio padrão para o tempo de consolidação da fratura foi de 36 ± 0 dias no GA e 34 ± 3,4 dias no GB. Os estudos anátomopatológicos revelaram que o processo de consolidação óssea no GB ocorreu mais precocemente que no GA nas etapas analisadas. Conclui-se que os dois fixadores são eficazes para o tratamento de fraturas diafisárias de úmero em pombos domésticos, sendo que o fixador com dois pinos perpendiculares promove maior estabilização do sítio da fratura embora necessite de tempo cirúrgico superior para sua confecção.
13

Influência da estimulação ultra-sônica de baixa intensidade no reparo de osteotomias de tíbias com fixação flexível / The influence of low-intensity ultrasound on the tibia osteomy healing of rabbits, with flexible fixation

Jorge, Fernando Augusto Jeronymo 17 September 2004 (has links)
O ultra-som de baixa intensidade tem demonstrado ser um recurso acelerador do processo de consolidação óssea em fraturas. Este estudo experimental investigou a influência da estimulação ultra-sônica de baixa intensidade no processo de reparo ósseo em fraturas de tíbias tratadas por meio de fixação flexível. O estudo foi desenvolvido no laboratório de Bioengenharia da FMRP da Universidade de São Paulo Campus de Ribeirão Preto, utilizando 20 coelhos machos adolescentes da raça Nova Zelândia, que foram submetidos a uma osteotomia no terço médio da tíbia e tratados com fixador externo unilateral. Após o procedimento cirúrgico os animais foram divididos em três grupos: controle com n = 7 (membro contralateral, não fixado), grupo controle lesão com n = 7 (fixados e mantidos em gaiolas) e grupo ultra-som com n = 7, que recebeu estimulação com equipamento de ultra-som de baixa intensidade (30mW/'CM POT.2') e ciclo de trabalho de 1/5. No final de 20 dias de tratamento suas tíbias foram retiradas e submetidas a ensaio mecânico de torção. Na avaliação das propriedades mecânicas torque máximo e rigidez, não foi observada diferença significativa (p '< OU =' 0,05) entre os grupos estimulados e controle lesão. Estes resultados sugerem que a estimulação ultra-sônica de baixa intensidade aplicada ao reparo de fraturas na presença de fixação flexível não influencia a velocidade e o padrão de consolidação da fratura / The low-intensity ultrasound has demonstrated to be an accelerator device on the process of recovering of bone fractures. This experimental study investigated the influence of the low-intensity ultrasound stimulation on the process of bone repairing of fractures of tibia treated with flexible fixator. The study was developed at the FMRP Bioengineering laboratory, of the University of Sao Paulo, campus of Ribeirao Preto, using 20 teenager male rabbits from the New Zealand breed which were subjected to an osteomy in the median third of the tibia and treated with an unilateral external fixator. After the surgical procedure the animals were divided into three groups: control with n = 7 (paw contralateral, not fixed), group control injury with n = 7 (fixed and kept in cages) and group ultrasound with n = 7, that received stimulation with low-intensity ultrasound equipment (30mW/'CM POT.2') and duty cycle 1/5. At the end of 20 days of treatment, their tibia were removed and subjected to a mechanical twist test. At the evaluation of the mechanical properties: maximum torque and hardness, it was not observed significant differences (p '< OU =' 0,05) among the stimulated groups and the control injury. These outcomes suggest that the low-intensity ultrasound applied for fractures healing in the presence of flexible fixation does not have influence on the velocity nor the standard of the fracture recovering
14

Avalia??o das propriedades mec?nicas de diferentes modelos de fixadores esquel?ticos externos tipo Ib de baixo custo. / Evaluation of mechanical properties of different models of low cost external skeletal fixators type Ib.

Brito, Vin?cius Villas B?as de 29 August 2008 (has links)
Made available in DSpace on 2016-04-28T20:18:30Z (GMT). No. of bitstreams: 1 2008 - Vinicius Villas Boas de Brito.pdf: 2268646 bytes, checksum: e949027c863bdba33b474d06d53aaebc (MD5) Previous issue date: 2008-08-29 / Six different frames of low cost external skeletal fixators used in veterinary orthopedics were submitted to mechanical evaluation of the axial compression. The apparatuses were separated in two different models, one with wooden connection bars (Pinnus ellioti) and another with PMMA (polymethylmethacrylate) connection bars. Tubes of polyvynil chloride (PVC) were used to simulate the bone model. Each model were respresented by frames elaborated in typo Ib configuration, with eight insertion pins (four per fragment/ two per connection bar in each fragment), 12 insertion pins (six per fragment/ three per connections in each fragment) and 16 insertion pins (eight per fragment/ four per connection bar in each fragment). We have employed a universal essay machine, model 4204, Instron, at a two cm/min speed to submit the models to axial compression force tests and thus calculate their stiffness, safety load and yield point. Within the results, stiffness increase with a higher number of insertion pins; significant difference between the two models of connection bars is not detected. Otherwise the strength necessary to promote a one milimeter displacement at the fracture gap (safety load) is higher at the wooden connection bars apparatuses; this value also increases if the number of fixation pins is elevated, except if we compare frames with 12 insertion pins (six per fragment/ three per connections in each fragment) and 16 insertion pins (eight per fragment/ four per connection bar in each fragment). The strength necessary to promote a permanent deformation at the apparatuses (yield point) do not show significant statistic difference. / Foram submetidos ? avalia??o mec?nica de compress?o axial seis diferentes conforma??es de fixadores esquel?ticos externos de baixo custo para aplica??o em ortopedia veterin?ria. Os aparelhos se diferenciavam em dois modelos, um com barras de conex?o de madeira (Pinnus ellioti) e outro com barras de conex?o de resina acr?lica autopolimeriz?vel. Foram utilizados tubos de policloreto de vinila (PVC) para simular os fragmentos ?sseos. Cada modelo possu?a aparelhos montados na configura??o tipo Ib, com oito pinos de inser??o (quatro por fragmento/ dois por barra de conex?o em cada fragmento), 12 pinos de inser??o (seis por fragmento/ tr?s por barra estabilizadora em cada fragmento) e 16 pinos de inser??o (oito por fragmento/ quatro por barra de conex?o em cada fragmento). Os corpos de prova foram submetidos ? for?a de compress?o axial pela m?quina de ensaio universal, modelo 4204, Instron, a velocidade de dois cm/min. Sendo mensurados a rigidez, carga m?xima de seguran?a e o ponto de escoamento. De acordo com os resultados, a rigidez aumenta de forma diretamente proporcional ao incremento no n?mero de pinos de inser??o; n?o ? observada diferen?a significativa entre os dois tipos de barras de conex?o. Por?m o valor de for?a necess?ria para causar um deslocamento de um mil?metro no foco de fratura (carga m?xima de seguran?a) ? mais elevado nos aparelhos com barras de conex?o de madeira; esse valor aumenta tamb?m com o incremento do n?mero de pinos de inser??o, excetuando-se quando se compara aparelhos com 12 pinos de inser??o (seis por fragmento/ tr?s por barra estabilizadora em cada fragmento) e 16 pinos de inser??o (oito por fragmento/ quatro por barra de conex?o em cada fragmento). J? os valores da for?a necess?ria para causar uma deforma??o permanente nos aparelhos (ponto de escoamento) n?o apresentaram diferen?a estatisticamente significativa.
15

Compara??o da Avalia??o Mec?nica de Compress?o Axial em Seis Modelos de Fixadores Esquel?ticos Externos Confeccionados com Barras Estabilizadoras de polimetacrilato de metila ou de Madeira e Parafusos de A?o Inoxid?vel 304. / Comparison of the Mechanical Evaluation of Axial Compression in Six Models of External Skeleton Fixators Manufactured with Stabilized Bars of Methyl Methacrylate or of Wood and Stainless Steel Screws 304.

Rocha, Carlos Ot?vio Jord?o Moreira da 29 August 2008 (has links)
Made available in DSpace on 2016-04-28T20:18:31Z (GMT). No. of bitstreams: 1 2008 - Carlos Otavio Jordao Moreira da Rocha.pdf: 1867760 bytes, checksum: 3392639adc640e871d82c97af23d8da8 (MD5) Previous issue date: 2008-08-29 / With the objective of testing the resistance and the biomechanical behavior of external fixators of low cost used in veterinary medicine, were created 6 prototypes la type manufactured from alternative materials, using as orthopedic implants, stainless steel screws 304 porous, and as stabilized bar the methacrylate resin or wood poles (Pinnus ellioti). The models of the fixators tested differ because they have 2, 3 or 4 implants per fractured segment. With the purpose of doing biomechanical evaluations that are closer to the real clinical situation, were selected 2 tubes of polyvinylchloride, commercially known as PVC, with 10 cm length, internal diameter of 1,27 cm and external diameter of 1,95, far 5 cm from each other, representing, this way, the bone bands and the focus of an unstable fracture. This kind of tube is like a long bone because it has an internal space that represents the medullar area and external walls that represent the two osseous cortical. To each external fixator model, were created 5 prototypes, which were submitted to mechanic tests to evaluate the axial compression strength. The device to evaluate the prototypes was the Instron model 4204, with a charge cell of 5 KN (Kilogram-Newton) and the speed of the axial compression was 2 cm/minute, according the rules ASTM D695-92. The values of rigidity, drainage point and maximum security charge were calculated, according to the methodology used by Willer et al., (1991) and by Falc?o (2004). The mechanical evaluation was done in the Instituto de Macromol?culas Elo?sa Mano in the Universidade Federal do Rio de Janeiro. We concluded that the models with the stabilized bar made of resin required a larger load than the models made of wood to suffer a plastic deformation. The model with 3 screws per segment of PVC tube and a resin stabilized bar showed to tolerate a higher weight than the others, before showing a plastic deformation, this way it s indicated to dogs that weight up to 26,5Kg with fractures in the thoracic limbs and for dogs that weight up to 44Kg that have fractures in the pelvic limbs. / Com objetivo de testar a resist?ncia e o comportamento biomec?nico de fixadores externos de baixo custo utilizados em medicina veterin?ria, foram criados 6 modelos de prot?tipos do tipo Ia confeccionados a partir de materiais alternativos, utilizando-se como implantes ortop?dicos parafusos de a?o inoxid?vel 304 porosos e totalmente rosqueados, e como barra estabilizadora a resina de metacrilato ou hastes de madeira (Pinnus ellioti). Os modelos dos fixadores testados ainda se diferenciam por apresentarem 2, 3 ou 4 implantes por segmento fraturado. Com a finalidade de realizar avalia??es biomec?nicas o mais pr?ximo poss?vel da situa??o cl?nica, optou-se pela escolha de 2 tubos de policloreto de vinila, comercialmente conhecido como PVC, apresentando 10 cm de comprimento, 1,27 cm de di?metro interno e 1,95 cm de di?metro externo, afastados 5 cm entre si, representando assim os fragmentos ?sseos e o foco de uma fratura inst?vel. Este tipo de tubo se assemelha a um osso longo por apresentar um espa?o interno que representa a ?rea medular enquanto que as paredes externas representam as duas corticais ?sseas. Para cada modelo de fixador externo foram criados 5 prot?tipos, submetidos a testes mec?nicos para avalia??o da for?a de compress?o axial. O aparelho para avalia??o dos prot?tipos foi o Instron modelo 4204, com c?lula de carga de 5 KN (Quilograma-Newton) e a velocidade da compress?o axial foi de 2 cm/minuto, seguindo as normas ASTM D695-91. Calculamos as cargas de rigidez, ponto de escoamento e carga de seguran?a m?xima. A avalia??o mec?nica foi realizada no Instituto de Macromol?culas Elo?sa Mano na Universidade Federal do Rio de Janeiro. Conclu?mos que os modelos com barra estabilizadora em resina necessitou de uma carga maior do que os modelos de madeira para sofrer deforma??o pl?stica. O modelo com 3 parafusos por segmento de tubo de PVC e barra estabilizadora de resina mostrou suportar maior peso que os demais, antes de apresentar uma deforma??o pl?stica, sendo indicado para c?es com peso corporal de at? 26,5 Kg portadores de fraturas nos membros tor?cicos e para c?es com peso de at? 44 Kg que apresentem fraturas nos membros p?lvicos.
16

Influência da estimulação ultra-sônica de baixa intensidade no reparo de osteotomias de tíbias com fixação flexível / The influence of low-intensity ultrasound on the tibia osteomy healing of rabbits, with flexible fixation

Fernando Augusto Jeronymo Jorge 17 September 2004 (has links)
O ultra-som de baixa intensidade tem demonstrado ser um recurso acelerador do processo de consolidação óssea em fraturas. Este estudo experimental investigou a influência da estimulação ultra-sônica de baixa intensidade no processo de reparo ósseo em fraturas de tíbias tratadas por meio de fixação flexível. O estudo foi desenvolvido no laboratório de Bioengenharia da FMRP da Universidade de São Paulo Campus de Ribeirão Preto, utilizando 20 coelhos machos adolescentes da raça Nova Zelândia, que foram submetidos a uma osteotomia no terço médio da tíbia e tratados com fixador externo unilateral. Após o procedimento cirúrgico os animais foram divididos em três grupos: controle com n = 7 (membro contralateral, não fixado), grupo controle lesão com n = 7 (fixados e mantidos em gaiolas) e grupo ultra-som com n = 7, que recebeu estimulação com equipamento de ultra-som de baixa intensidade (30mW/'CM POT.2') e ciclo de trabalho de 1/5. No final de 20 dias de tratamento suas tíbias foram retiradas e submetidas a ensaio mecânico de torção. Na avaliação das propriedades mecânicas torque máximo e rigidez, não foi observada diferença significativa (p '< OU =' 0,05) entre os grupos estimulados e controle lesão. Estes resultados sugerem que a estimulação ultra-sônica de baixa intensidade aplicada ao reparo de fraturas na presença de fixação flexível não influencia a velocidade e o padrão de consolidação da fratura / The low-intensity ultrasound has demonstrated to be an accelerator device on the process of recovering of bone fractures. This experimental study investigated the influence of the low-intensity ultrasound stimulation on the process of bone repairing of fractures of tibia treated with flexible fixator. The study was developed at the FMRP Bioengineering laboratory, of the University of Sao Paulo, campus of Ribeirao Preto, using 20 teenager male rabbits from the New Zealand breed which were subjected to an osteomy in the median third of the tibia and treated with an unilateral external fixator. After the surgical procedure the animals were divided into three groups: control with n = 7 (paw contralateral, not fixed), group control injury with n = 7 (fixed and kept in cages) and group ultrasound with n = 7, that received stimulation with low-intensity ultrasound equipment (30mW/'CM POT.2') and duty cycle 1/5. At the end of 20 days of treatment, their tibia were removed and subjected to a mechanical twist test. At the evaluation of the mechanical properties: maximum torque and hardness, it was not observed significant differences (p '< OU =' 0,05) among the stimulated groups and the control injury. These outcomes suggest that the low-intensity ultrasound applied for fractures healing in the presence of flexible fixation does not have influence on the velocity nor the standard of the fracture recovering