• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 340
  • 39
  • 21
  • 14
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 420
  • 274
  • 90
  • 80
  • 75
  • 68
  • 59
  • 53
  • 49
  • 47
  • 46
  • 46
  • 45
  • 44
  • 41
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
191

Análise de estabilidade de mancais de deslizamento

Janaina Tomazoni Santos 21 August 2009 (has links)
Este trabalho objetiva prover subsídios para análise de estabilidade de sistemas eixo-mancal de deslizamento carregados dinamicamente, sob lubrificação hidrodinâmica por filme fluido. A equação da pressão na qual se baseia todo o desenvolvimento apresentado neste trabalho foi concebida por Sommerfeld. Sendo esta fundamentada na teoria de mancais infinitamente longos, assume-se que o mancal de deslizamento considerado insere-se neste contexto. As expressões para as componentes de força radial e tangencial do sistema eixo-mancal em questão podem ser obtidas para as conhecidas soluções de Half Sommerfeld e Full Sommerfeld, integrando a equação da pressão de Sommerfeld. A resolução dessa integração foi obtida através da utilização de fórmulas recursivas tabeladas por Booker, para integrais que apresentam uma mesma forma característica, denominadas Integrais de Booker, e nas quais resulta o desmembramento da integral principal. Linearizando as forças por expansão de Taylor de primeira ordem, geram-se os coeficientes das matrizes características do sistema. A implementação numérica foi feita sobre as forças e matrizes obtidas para Half Sommerfeld utilizando o Método de Newmark, e abrangendo dois casos, ordem zero e primeira ordem. Ambos são analisados e confrontados no que concerne os resultados de convergência e divergência numéricas, e efeito half-speed whirl. Conclusões e considerações finais são tecidas com respeito às características, vantagens e desvantagens, e relevância para aplicação prática. Sobre estes propósitos, observa-se que a formulação em primeira ordem mostra-se mais vantajosa por permitir utilização de intervalos de tempo maiores para descrever a trajetória assumida pelo centro do eixo. Outra contribuição deste trabalho, e não menos importante, é a obtenção de uma formulação geral para as expressões das componentes de força, bem como das matrizes de rigidez e amortecimento. Além de se poder obter as mesmas expressões resultado geradas pelas soluções de Half e Full Sommerfeld, os limites de integração são livres para assumir quaisquer valores de posicionamento angular, e não restringem o intervalo de integração a ? ou a 2?.
192

Análise do movimento de eixo sustentados por mancais do tipo squeeze film.

Hudson Alberto Bode 00 December 2002 (has links)
O objetivo principal desta proposta é a de analisar o uso do squeeze-films como um apoio flexível de um sistema eixo-mancal, com um enfoque computacional. As forças produzidas pela pressão dinâmica do lubrificante são obtidas pela solução da equação de Reynolds para o filme de fluido. Para tratar das equações que governam o movimento dos eixos rotores apoiados por squeeze-films, o método de Newmark foi empregado. Parâmetros associados à massa e velocidade do eixo e às características físicas e geométricas do mancal, tal como a viscosidade do fluido, a folga radial, comprimento e diâmetro do mancal, foram variados para permitir avaliações do comportamento orbital do eixo. Determinados grupos de parâmetros foram selecionados e, foi estudada a influência da força que produz o desequilíbrio do eixo. Resultados revelaram uma sensibilidade na estabilidade de movimento e o tamanho orbital para todos os parâmetros.
193

Desenvolvimento da modelagem de turbulência e interação fluido-estrutura para as vibrações induzidas por vórtices de cilindro rígido. / Improvements in the numerical modeling of turbulence and fluid-structure interaction for the vortex-induced vibrations of a rigid cylinder.

Rosetti, Guilherme Feitosa 18 June 2015 (has links)
Esta tese apresenta o desenvolvimento e aplicação de modelos de turbulência, transição laminar-turbulenta e de interações fluido-estrutura ao escoamento externo em cilindro rígido estacionário e em vibrações induzidas por vórtices. Tais desenvolvimentos foram realizados no código ReFRESCO, baseado em técnicas de dinâmica de fluidos computacional (CFD). Realizou-se um estudo quanto ao desempenho do modelo k- SST em extensa faixa de números de Reynolds, segundo o qual se identificaram as deficiências de modelagem para este escoamento. A modelagem adaptativa das escalas (SAS) e o modelo de transição por correlações locais (LCTM), ambos combinados ao SST, melhoraram a aderência aos resultados experimentais para este escoamento, em uma contribuição original deste trabalho. A aplicação de técnicas de verificação e validação possibilitou a estimação de incertezas e erros para os modelos e números de Reynolds e também de identificada como outra contribuição deste trabalho. A combinação da modelagem em SST, SAS e LCTM com movimentos impostos de realizada para números de Reynolds moderados, diferentes frequências e amplitudes de vibração, algo que poucas publicações abordam em detalhes. Com relação aos movimentos livres, este trabalho traz contribuições com a aplicação dos modelos SST e SAS ao estudo de vibrações induzidas por vórtices em dois graus de liberdade, baixa razão de massa e números de Reynolds moderados, mais altos do que normalmente observados na literatura. Por fim, a investigação da importância relativa de efeitos da turbulência aos casos de movimentos livres e impostos, com relação ao caso de cilindro estacionário, comprovou a conjetura formulada na parte inicial deste trabalho, no que tange à escolha do modelo de turbulência em determinadas aplicações. Tal escolha mostrou-se menos decisiva no caso do cilindro em movimento imposto e ainda menos nos movimentos livres, em comparação ao caso estacionário, uma vez que a resposta em movimentos do corpo filtra grande parte dos efeitos turbulentos de ordem superior. Esta observação mostra-se relevante, uma vez que pode permitir simplificações na modelagem e aplicação de ferramentas de CFD em uma classe importante de projetos de engenharia. / This thesis presents the development, implementation and application of turbulence and laminar-turbulent transition models and fuid-structure capabilities to address the vortexshedding and vortex-induced vibrations of a rigid cylinder. These numerical developments have been carried out in the computational fuid dynamics (CFD) code ReFRESCO. In the current work, an investigation of the performance of the turbulence modeling with k- SST in a broad range of Reynolds numbers is carried out identifying its modeling deficiencies for this fow. The implementation and systematic application of the scale adaptive simulations (SAS) and the local correlation transition model (LCTM), both combined with the SST, have improved the agreement with experimental results for the cylinder ow, in a novel contribution of this work. The application of verification and validation technique has allowed the estimation of numerical errors and uncertainties for the diferent models. That is also identified as a contribution of this thesis. The combination of SST modeling with imposed motions is carried out as well as with the SAS and LCTM for moderate Reynolds numbers, diferent vibration frequencies and amplitudes, which is considered novel, as few publications address this issue in extent. Regarding the free-moving cylinder capabilities, the present work brings contributions with the application of SST and SASSST with free-moving cylinder for the study of VIV of two degrees of-freedom, low mass ratio and moderate Reynolds numbers, higher than commonly seen in the literature. Finally, the investigation of the relative importance of turbulence effects on the freemoving cylinder and the imposed-motions case, with respect to the fixed case is carried out. A natural conjecture that has been raised early on this work and proved correct is that, for engineering applications, the choice of turbulence modeling strategy is less decisive when the cylinder is moving with prescribed motion and even less stringent, for free motions as the body response filters most of the higher order turbulence effects. That is a relevant observation as it might allow modeling simplifications and the application of CFD tools to a range of engineering problems.
194

Efeito do tratamento periodontal não cirúrgico na atividade da peroxidase na saliva da glândula parótida e no fluído gengival / Effect of non Surgical Periodontal Therapy on Peroxidase Activity in Parotid Saliva and Gingival Crevicular Fluid

Rogéria Pereira Gonçalves 10 September 2012 (has links)
Dois importantes fatores inter-relacionados estão envolvidos na patogênese da doença periodontal: ativação do sistema imune e produção de peroxidases. Os objetivos deste estudo foram comparar os níveis da atividade do sistema peroxidase presentes no fluido gengival (MPO/FG) e saliva da parótida (POS) em pacientes portadores de periodontite crônica em relação a pacientes periodontalmente saudáveis e avaliar o efeito do tratamento periodontal não cirúrgico nestes indivíduos nestes parâmetros enzimáticos. MATERIAL E MÉTODO: Foram coletados dados dos parâmetros clínicos periodontais e amostras de FG e saliva da glândula parótida de 17 pacientes clinicamente saudáveis (GC) e de 17 pacientes portadores de periodontite crônica generalizada (GP) antes e depois do tratamento periodontal pareados em idade e sexo. As atividades de MPO/FG e POS Parótida foram avaliadas por espectofotometria. RESULTADOS: O GP apresentou valores maiores nos parâmetros clínicos periodontais em relação ao GC, sendo que os mesmos foram reduzidos após tratamento periodontal. Além disso, o GP apresentou valores mais elevados de atividade de MPO no FG (p=0,04) do que o GC. Após tratamento periodontal os níveis de MPO/FG (p<0,001) e POS parótida (p=0,013) foram reduzidos significativamente. No GP houve correlação negativa e significativa entre POS da parótida e MPO no FG (r=-0,59, p=0,02). CONCLUSÕES: Na doença periodontal, as atividades de MPO no FG são maiores quando comparados ao grupo controle, e tanto de MPO/FG e POS parótida são reduzidas após tratamento periodontal. / Two important and interrelated factors are involved in the pathophysiology of periodontal diseases: the activation of immune system and the production of peroxidases. The objectives of this study were to examine the peroxidase activities present in Gingival Crevicular Fluid (MPO/GCF) and in Parotid Saliva (POS) in patients with generalized chronic periodontitis with healthy controls and to compare the effects of periodontal therapy on enzyme activities. MATERIAL AND METHOD: Periodontal clinical measurements, parotid saliva and GCF samples were obtained of 17 age-matched healthy controls (PC) and 17 patients with chronic periodontal disease (PD) before treatment and after periodontal treatment. The MPO/GCF and POS parotid activities were determined spectrophotometrically. RESULTS: In PD group, clinical parameters, MPO/GCF (p=0,04) activities presented higher values than controls. After periodontal treatment levels of MPO/GCF (p<0.001) and POS parotid (p=0,013) were significantly reduced. In PD there was significant negative correlation between POS and MPO in the parotid FG (r =-0,59, p=0,02). CONCLUSIONS: In periodontal disease MPO/GCF presented higher levels than controls and MPO/GCF and POS parotid are reduced after treatment.
195

Otimização de estruturas com fluido contido sujeita a múltiplos carregamentos. / Optimization of contained fluid structures subjected to multiple load cases.

Miracca, Fábio Brescia 26 March 2007 (has links)
Muitas vezes encontram-se na Engenharia, estruturas que contenham fluido em seu interior, (estruturas com fluido contido). Uma vez que para determinados casos de carregamento, como por exemplo, carregamento hidrostático, o fluido colabora com a rigidez, pode ser conveniente para o engenheiro considerar a presença deste fluido com o objetivo de se obter uma estrutura mais leve, principalmente nos casos onde a presença do fluido é obrigatória à operação da estrutura. Nesta dissertação, uma metodologia para otimização de estruturas com fluido contido é apresentada. Tal metodologia engloba a otimização de uma estrutura real, utilizando otimização paramétrica (OP) e topológica (OT). A rotina de OT implementada permite projetar estruturas compostas de aço e fluido contido (FC), e considera múltiplos casos de carregamento, peso próprio e a possibilidade de escolha de regiões a serem otimizadas ou não. Para validação da rotina de OT, exemplos clássicos da literatura considerando a presença de um ou dois materiais são apresentados. Para implementar o algoritmo para resolução da OT utiliza-se um programa comercial para a análise de elementos finitos, complementado com uma rotina externa elaborada em linguagem do próprio programa. Isto possibilita agregar a vantagem da utilização de um programa comercial, multidisciplinar, e com um grande número de elementos finitos implementados, com a versatilidade de uma linguagem de programação, permitindo implementar uma solução específica para o problema estudado. Como exemplo, apresenta-se um estudo de caso real, voltado a estruturas navais, apresentando, além da análise da estrutura inicial estudada, uma otimização paramétrica, e uma otimização topológica tridimensional da estrutura. Os resultados alcançados, mostram-se satisfatórios, uma vez que a estrutura obtida no estudo de caso específico apresenta uma redução significativa em seu peso atendendo aos requisitos de projeto. / Several times, it is found in Engineering, structures with fluid inside (contained fluid structures). Since for some load cases, for instance, hydrostatic load, the fluid collaborates with stiffness, it may be convenient for the engineer to take into account this fluid to make the structure lighter, mainly if the presence of fluid is mandatory for operation. In this work, a methodology for contained fluid structures optimization is presented. This methodology includes parametric and topology optimizations of a real structure. Topology optimization routine implemented allows us to design structures made by steel and contained fluid, and includes several load cases, self-weight, and the possibility of choosing areas to optimize or not. To validate the topology optimization routine, classical examples with one or two material are showed. To perform topology optimization procedure, Finite Element Analysis commercial software is applied together with an external routine implemented using the software programming language, this allows us to take advantage of a multidisciplinary commercial software, which has a large number of finite elements implemented, and the versatility of a customized program for the studied problem. As an example, it is showed a real case, within naval structures describing the initial structure analysis and its parametric optimization, and a tridimensional topology optimization. The results obtained are satisfactory, since the final structure obtained has a significant reduction in its weight.
196

Extração de compostos fenólicos de Butia capitata utilizando dióxido de carbono supercrítico

Toss, Daniel January 2010 (has links)
O presente trabalho investiga a aplicação do processo de extração com fluido supercrítico (EFS) para a obtenção de compostos fenólicos a partir de Butia capitata, coletado na Região Sul do Brasil. A planta, chamada popularmente de butiá, é uma espécie nativa da Argentina, Uruguai, Paraguai e Brasil. Os frutos do butiá são comestíveis e bastante apreciados pelas populações locais, que os consomem ao natural ou na forma de licores, geléias ou doces. Estudos recentes revelam que compostos fenólicos estão presentes nos frutos do butiá. Estes compostos merecem atenção por apresentarem atividade antioxidante, por prevenirem doenças cardiovasculares e reduzirem o risco de câncer. Atualmente existem diferentes formas para a obtenção de compostos fenólicos presentes em matrizes vegetais, porém muitas delas utilizam solventes orgânicos a altas temperaturas, o que deprecia o valor comercial dos extratos. Neste estudo, é utilizada uma tecnologia limpa, que tem como solvente o dióxido de carbono (CO2) em condições supercríticas. O CO2 é não-tóxico e não-inflamável, o que faz dele uma opção mais segura, quando comparado a outros solventes. Além disso, no estado supercrítico, o CO2 apresenta condições bastante favoráveis para a extração, como altas difusividades e massas específicas elevadas. Uma característica que deve ser ressaltada é a possibilidade de utilizar baixas temperaturas na extração, comparativamente aos processos que utilizam solventes líquidos, uma vez que os compostos fenólicos são termolábeis. Nos experimentos, foi utilizada apenas a polpa desidratada. O planejamento experimental foi elaborado avaliando a influência de três variáveis de processo em três níveis: pressão (150, 200 e 250 bar), temperatura (40, 50 e 60°C) e teor de cossolvente (1, 3 e 5% de etanol). Os extratos obtidos foram analisados em cromatografia líquida de alta eficiência (CLAE), sendo os rendimentos expressos em mg do composto identificado por CLAE /100g de polpa de butiá desidratada (PBD), e pelo método Folin-Ciocalteau com os rendimentos em compostos fenólicos totais (CFT) expressos em mg de rutina equivalente (RE)/100g PBD. Foram identificados cinco compostos majoritários nos extratos nas análises em CLAE. As maiores concentrações foram encontradas nas condições de 250 bar, 60°C e 5% de etanol. Os compostos identificados foram o ácido clorogênico (0,46mg/100g PBD), o ácido ferúlico (1,45mg/100g PBD), a rutina (3,47mg/100g PBD), a quercetina (0,90mg/100g PBD) e o canferol (1,93mg/100g PBD). Em termos de CFT, a melhor condição de extração foi de 200 bar, 50°C e 5% de etanol, resultando em 23,09mg RE/100g PBD. Os extratos também foram avaliados quanto ao poder de redução do radical DPPH•, pelo método IC50. O método fornece a quantidade necessária de extrato pra varrer 50% do radical. Como esperado, o extrato obtido na corrida experimental de maior rendimento em CFT apresentou maior atividade antioxidante (17,4 mg/mL), seguido da corrida experimental de maior rendimento em compostos fenólicos isolados (56,1 mg/mL) e, com menos atividade, o extrato obtido por solvente orgânico (80,0 mg/mL). / In this work it is investigated the application of supercritical fluid extraction to obtain phenolic compounds from Butia capitata, collected in southern Brazil. This plant, known popularly as butiá, is a native species in Argentina, Uruguay, Paraguay and Brazil. The edible fruits are popular and eaten raw or as liqueurs, jellies or jams. In recent studies, it is shown that phenolic compounds are present in the fruits of butiá. These compounds deserve attention because they have antioxidant activity, preventing cardiovascular disease and reducing the risk of cancer. There are different processes to obtain phenolic compounds from plant matrices, but many of them make use of organic solvents at high temperatures, which depreciates the extract value. In this study, it is used a clean technology, with carbon dioxide (CO2) as solvent in supercritical conditions. The CO2 is nontoxic and nonflammable that makes it a safer option than other solvents. Furthermore, in supercritical conditions the CO2 has favorable conditions for extraction, as high diffusivities and densities. A feature that should be emphasized is the possibility of using low temperatures in the extract, when compared to processes using liquid solvents, since the phenolic compounds are decomposed by high temperature. In the experiments only the dried pulp was used. The experimental design was developed to assess the influence of three process variables at three levels: pressure (150, 200 e 250 bar), temperature (40, 50 e 60°C) and cosolvent content (1, 3 e 5% of ethanol). The extracts were analyzed by high performance liquid chromatography (HPLC), in which the yields were expressed in terms of mg of the identified phenolic compounds by HPLC/100g of dried pulp and by the Folin-Ciocalteau method, with yields, as total phenolic compounds, expressed in mg of rutin equivalent/100g of dried pulp. It were identified five majority phenolic compounds by HPLC. Its highest concentrations were found in the conditions of 250 bar, 60°C and 5% of cosolvent. The identified compounds were chlorogenic acid (0,46mg/100g of dried pulp), ferulic acid (1,45mg/100g of dried pulp), rutin (3,47mg/100g of dried pulp), quercetin (0,90mg/100g of dried pulp) and kaempferol (1,93mg/100g of dried pulp). In terms of total phenolic compounds, the best conditions were 200 bar, 50°C and 5% of cosolvent, which resulted in 23,09mg of rutin equivalent/100g of dried pulp. Also, the antioxidant activity of the extracts was measured by scavenging of the DPPH• radical, by the IC50 method. The method provides the necessary amount of extract to scavenging 50% of the radial. As expected, the extract obtained in experimental run with the highest yield in CFT showed a higher antioxidant activity (17.4 mg / mL), followed by the experimental run with the highest yield in phenolic compounds isolated (56.1 mg / mL), and, with less activity, the extract obtained by organic solvent (80.0 mg / mL).
197

Efeito do tratamento periodontal não cirúrgico em pacientes com periodontite crônica e agressiva: achados microbiológicos e imunológicos / Effect of non surgical periodontal treatment in chronic and aggressive subjects: microbiological and immunological findings

Wilson Rosalem Junior 29 March 2010 (has links)
O objetivo do presente estudo foi comparar a expressão de IL-1&#946;, IL-4, IL-8, interferon-&#947;, atividade de elastase e a composição do perfil microbiano subgengival antes e depois do tratamento periodontal não cirúrgico em pacientes com doença peridontal crônica generalizada (PC) e agressiva generalizada (PA). Vinte pacientes com PC e quatorze com PA foram avaliados. Dados clínicos, fluido gengival e biofilme subgengival foram analisados na visita inicial (VI) e 3 meses (3M) após o tratamento periodontal não cirúrgico. Amostras de fluido gengival (FG) foram coletadas com tiras de papel e os níveis de: IL-1&#946;, IL-4, IL-8 e INF-&#947; foram medidos, utilizando um tipo de imunoensaio multiplexado (Luminex). Atividade da elastase foi avaliada por um ensaio enzimático. Amostras de placa subgengival foram analisadas através do checkerboard DNA-DNA hybridization. Na avaliação de 3 meses após terapia periodontal foi encontrado melhora significativa para todos os parâmetros clínicos em ambos os grupos. Foram encontradas reduções significativas na atividade de elastase nos sítios rasos e profundos dos pacientes do grupo PA e nos sítios profundos do grupo PC, também foi achado um aumento significativo de INF-&#947; nos sítios rasos do grupo PA. Os dados microbiológicos, mostraram reduções significativas para os níveis dos membros do complexo vermelho (P. gingivalis, T. forsythia, T.denticola), e para as espécies E.nodatum e P.micra no grupo PC. No grupo PA, ocorreram reduções significativas no níveis de P. gingivalis, T. forsythia, Fusobacterium nucleatum ss polymorphum e Fusobacterium periodonticum. Quando as respostas clínica e imunológica 3M após terapia foram comparadas entre os grupos, apenas diferenças sutis foram observadas. Nenhuma diferença microbiológica foi encontrada entre os grupos após a terapia. Em conclusão, os achados suportam nossa hipótese de que as periodontites cronica e agressiva respondem de forma semelhante ao tratamento periodontal nao cirúrgico. / Our aim was to compare the expression of IL1&#946;, IL-4, IL-8, INF-&#947;, elastase activity and the composition of the subgingival microbiota profile before and after non-surgical periodontal treatment in patients with untreated generalized chronic (GCP) and aggressive periodontitis (GAgP). Twenty patients with GCP and 14 with GAgP were evaluated. Clinical data, GCF and plaque were analyzed at baseline and 3 months after non-surgical periodontal treatment. IL-1&#946;, IL-4, IL-8 and INF&#947; were analyzed in a luminex assay. Elastase activity was assessed by an enzymatic assay. Subgingival plaque samples were analyzed using checkerboard DNA-DNA hybridization. Three months after periodontal therapy significant improvement for all clinical parameters in both groups were found. We have found significant reductions in the elastase activity in shallow and deep sites from GAgP and in deep sites from GCP group. A significant increase in INF-&#947; in the shallow sites from GAgP group were also found. Microbiological data showed significant reductions in the levels of members of the red complex (P. gingivalis, T. forsythia, T. denticola), and for the species E.nodatum and P.micra on GCP group. In the GAgP group, there were significant reductions in levels of P. gingivalis, T. forsythia, Fusobacterium nucleatum and Fusobacterium polymorphum ss periodonticum. When the clinical and immunological responses after therapy were compared between groups, only slight differences were found. No microbiological difference was found between groups after therapy. In conclusion, the findings support our hypothesis that the chronic and aggressive periodontitis respond equally well to non-surgical periodontal treatment.
198

Impacto da terapia mecânica não cirúrgica em pacientes com periodontite crônica e agressiva generalizadas / Impact of non-surgical periodontal therapy on generalized chronic and aggressive periodontitis

Karina Schittine Bezerra Lomba 26 February 2010 (has links)
O objetivo deste estudo foi avaliar o impacto do tratamento periodontal não cirúrgico sobre a atividade de elastase e o volume de fluido gengival nos pacientes portadores de periodontite crônica e agressiva generalizadas. Foram avaliados 18 pacientes com periodontite crônica (idade média 48,6 DP 7,5 anos), e 11 com periodontite agressiva (idade média 27,9 DP 6,54 anos). Foram utilizados os parâmetros clínicos de avaliação de profundidade de bolsa à sondagem (PB) (mm), nível de inserção (NI) (mm) e sangramento à sondagem (SS). As medidas clínicas e as amostras de fluido gengival foram colhidas a partir dos cinco sítios mais profundos (P) e de cinco sítios rasos com gengivite (G) de cada paciente, antes e 90 dias após o término do tratamento. As etapas clínicas obedeceram ao seguinte cronograma: seleção e exame periodontal; coleta de fluido gengival; tratamento periodontal; reavaliação, compreendendo o exame periodontal e coleta de fluido gengival. O tratamento levou, em média, 4 sessões de 40 minutos cada por paciente, com intervalo de 1 semana entre elas. As consultas para reavaliação foram feitas 90 dias após o término do tratamento. O teste de Wilcoxon foi utilizado para comparar os dados antes e depois do tratamento e o teste não pareado de Mann-Whitney U-test foi utilizado para comparar os grupos de periodontite crônica e agressiva. A amostra analisada antes e após o tratamento não apresentou diferenças significativas entre o grupo com periodontite crônica e agressiva, que responderam de forma similar a todos os indicadores avaliados, exceto para a profundidade de bolsa à sondagem nos sítios rasos com gengivite (p = 0,039) e para o sangramento à sondagem (p = 0,021) nos sítios profundos, ambos mais reduzidos na periodontite crônica após o tratamento. A elastase apresentou, após o tratamento, redução significativa nos sítios profundos, para a periodontite crônica (p = 0,012) e agressiva (p = 0,02). Em relação ao volume de fluido gengival, houve significativa redução após o tratamento nos pacientes com periodontite crônica e agressiva, tanto nos sítios rasos (p = 0,03 e p = 0,03) como nos profundos (p &#706; 0,001 e p = 0,003), respectivamente. Concluindo, os grupos com periodontite crônica e agressiva generalizadas comportaram- se de maneira semelhante frente à terapia mecânica não cirúrgica. Ainda, a terapia periodontal mecânica não cirúrgica mostrou redução significativa do volume de fluido gengival em todos os sítios analisados, e da atividade neutrofílica, nos sítios profundos, associada a reduções significativas em todos os indicadores clínicos analisados após o tratamento. / The aim of this study was to investigate the impact of non-surgical mechanical treatment on elastase activity and gingival crevicular fluids (GCF) volume of patients with untreated generalized chronic and aggressive periodontitis. Eighteen patients with generalized chronic periodontitis (mean age 48,6 SD 7,5 years old) and eleven with generalized aggressive periodontitis (mean age 27,9 SD 6,54 years old) were evaluated. The clinical parameters adopted were pocket probing depth (PPD) (mm); attachment level (AL) (mm) and bleeding on probing (PB). Clinical measures and GCF were collected from the 5 deepest sites (P) and from 5 shallow sites with gingivitis (G) from each patient of each group, before and 90 days after non- surgical periodontal treatment. There were adopted the following clinical steps: patients selection and periodontal exam; GCFs collection; periodontal treatment; re- evaluations, comprising periodontal exams and GCFs collection. The periodontal treatment lasted about about 4 sections with 40 minutes each, 1 section per week. Re-evaluations were performed 90 days after completion of the treatment. Wilcoxons statistic test compared the data before and after treatment and Mann-Whitneys non parametric U-test was used to compared chronic and aggressive periodontitis groups. There were no significant differences for all clinical parameters analysed before and after treatment,except for pocket probing depth on shallow sites (p = 0,039) and for bleeding on probing (p = 0,021) on deep sites, both in lower levels in chronic periodontitis after treatment. The elastases activity showed, after treatment, a significant reduction on deep sites for chronic (p = 0,012) and aggressive (p = 0,02) periodontitis. In concern to GCFs volume, there was significant reduction on both chronic and aggressive periodontitis, in shallow (p = 0,03 e p = 0,03) and in deep pockets (p &#706; 0,001 e p = 0,003), respectively, after treatment. In conclusion, both groups responded simmilarly to the mechanical non- surgical treatment. Moreover, non- surgical periodontal treatment showed significant reductions on GCFs volume on all analysed sites and reduction on neutrophilics activity, on deep sites followed by the significant reduction on clinical indicators after treatment.
199

Avaliação dos níveis de metaloproteinases da matriz no fluido gengival durante a movimentação dentária ortodôntica / Evaluation of the matrix metalloproteinases levels in the gingival crevicular fluid during orthodontic tooth movement

Cristiane Canavarro Rodrigues Martins 30 March 2010 (has links)
Fundação de Amparo à Pesquisa do Estado do Rio de Janeiro / Durante o tratamento ortodôntico, a resposta inicial dos tecidos periodontais ao estímulo mecânico envolve várias alterações estruturais e bioquímicas que permitem a movimentação do dente. As metaloproteinases da matriz (MMPs) parecem desempenhar um papel importante na manutenção da integridade funcional da matriz extracelular periodontal. O objetivo do presente estudo foi avaliar, em diferentes intervalos de tempo, os níveis de metaloproteinases da matriz -1, -2, -3, -7, -8, -12 e -13 no fluido gengival (FG) de caninos superiores submetidos ao movimento de distalização e testar a hipótese de possíveis alterações nos níveis destas MMPs com o emprego de forças ortodônticas. Amostras de FG foram obtidas de dezesseis pacientes ortodônticos saudáveis (nove do sexo masculino e sete do sexo feminino, com idades entre 13 e 27 anos, média de idade 17,7 anos) que possuíam indicação de exodontias dos primeiros pré-molares superiores e tiveram os caninos distalizados como parte da terapia ortodôntica. Um dos caninos superiores foi distalizado ortodonticamente, sendo considerado dente teste. O canino contralateral não foi submetido a nenhuma força, no entanto foi incluído na aparatologia ortodôntica e utilizado como controle. A coleta de FG foi realizada nos sítios mesial (tensão) e distal (pressão) dos dentes testes e controles 7 dias antes da montagem da aparatologia ortodôntica, imediatamennte após a aplicação da força ortodôntica, e após 1 h, 24 h, e 7, 14 e 21 dias, respectivamente denominados -7d, 0h, 1h, 24h, 7d, 14d e 21d. A arcada superior de cada paciente foi dividida em um lado teste e um lado controle. Os resultados mostraram que foram encontradas diferenças significativas no volume do FG apenas nos intervalos de tempo entre -7d e 0h nos lados controle-pressão (CP), teste-tensão (TT) e teste-pressão (TP). Em TP foi observado ainda aumento do volume entre os tempos 0h e 14d. Foi possível detectar no FG as MMPs estudadas nos lados controle/teste e lados pressão/tensão, em todos os intervalos de tempo. As flutuações dos níveis das MMPs apresentaram poucas alterações significativas nos diferentes intervalos de tempo, nos lados controle/teste e lados pressão/ tensão. As diferenças intergrupos (TT, TP, CT e CP) em cada tempo não mostraram resultados significativos assim como as comparações entre os lados pressão e tensão para cada tempo individualmente. Os níveis de expressão da MMP-8 foram muito superiores aos das outras MMPs avaliadas, porém sem diferenças signficativas entre os lados teste e controle. / During orthodontic treatment, the initial response of periodontal tissues to mechanical stress involves several structural and biochemical changes that allow the tooth movement. The matrix metalloproteinases (MMPs) seem to play an important role in maintaining the functional integrity of periodontal extracellular matrix. The aim of this study was to evaluate, in different periods, the levels of matrix metalloproteinases -1, -2, -3, -7, -8, -12 and -13 in gingival crevicular fluid (GCF) of the superior caninessubmitted to distalization movement and test the hypothesis of possible changes in these MMPs levels with the use of orthodontic forces. GCF samples were obtained from sixteen healthy orthodontic patients (nine males and seven females with ages ranging between 13 and 27 years, mean age 17.7 years) who had indication of first superior bicuspids extraction with cuspids distalization as part of orthodontic treatment. One maxillary canine was subjected to a distalizing force, and considered as the test tooth. The contralateral canine, which was not subjected to any force but was included in an orthodontic appliance, was used as a control. GCF sampling was performed at both mesial (tension) and distal (pressure) sites of the controls and tests teeth 7 days before applying the orthodontic appliance, immediately before applying the orthodontic force, and after 1 h, 24 h, and 7, 14 and 21 days, respectively called -7d, 0h, 1h, 24h, 7d, 14d and 21 d. The results showed significant differences in the GCF volume only in time intervals of 0h-7d on control-pressure (CP), test-tension (TT) and test-pressure (TP) sides. In TP side was observed an increase in volume between the time 0h and 14d. It was possible to detect in GCF all MMPs studied on control/test sides and pressure/tension sides at all periods. Fluctuations in levels of MMPs showed few significant changes in different periods on the sides control/test and pressure/tension. The differences between the groups (TT, TP, CT and CP) in each time showed no significant results as well as the comparisons between pressure and tension sides for each period individually. The expression levels of MMP-8 were much higher than those of other MMPs evaluated, but with no significant differences between sides test and control.
200

Modelagem numérica do escoamento num tubo permeável aplicada ao processo de filtração tangencial / Numerical modeling of the flow in permeable tube applied to the cross-flow filtration process

Juliana Maria da Silva 14 March 2008 (has links)
Estudos aplicados ao processo de filtração tangencial têm sido o objetivo de muitos trabalhos devido a sua ampla capacidade de adequação aos mais diversos processos industriais. Os mecanismos de transferência associados a esse processo envolvem basicamente o escoamento em tubos permeáveis (ou membranas) com fenômenos de transferência de massa presentes junto à superfície. Esta tese de doutorado apresenta uma modelagem numérica capaz de representar o escoamento de fluidos newtonianos e não-newtonianos em tubos permeáveis aplicada ao processo de filtração tangencial, para os regimes de escoamento laminar e turbulento. No regime turbulento, utilizou-se o modelo de comprimento de mistura de Prandtl. O modelo numérico envolveu as equações de conservação da massa, da quantidade de movimento e das espécies químicas, acopladas a adequadas condições de fronteira. Em particular, por se tratar de um modelo numérico, analisou-se a discretização dos termos convectivos por meio da implementação de três esquemas: WACEB, CUBISTA e QUICKEST adaptativo. Os resultados produzidos pela implementação dos esquemas convectivos foram analisados por meio de comparações com resultados analíticos e experimentais da literatura, para regimes de escoamento laminar e turbulento. De acordo com as comparações realizadas, o esquema QUICKEST adaptativo apresentou melhor desempenho na modelagem desse escoamento. Diversas simulações numéricas geraram resultados, os quais foram comparados com expressões analíticas e dados experimentais da literatura e com dados produzidos pelo laboratório do Núcleo de Engenharia Térmica e Fluidos (NETeF) da USP São Carlos. Verificou-se, assim, que o modelo matemático produziu resultados compatíveis com o fenômeno estudado, tendo-se, portanto, uma ferramenta para descrição do problema convectivo mássico do escoamento em tubos permeáveis. / Studies applied to the crossflow filtration process have been the goal of several researches due to its large capacity for adaptation to the various industrial processes. The mechanism of transfer associated with this process basically involves fiows in permeable tubes (or membranes) with the phenomenon of mass transfer on the surface. This doctoral thesis presents a numerical modeling able to represent the fiow of Newtonian and non-Newtonian fiuids in permeable tubes applied to the process of crossflow filtration, in laminar and turbulent flow regimes. In the turbulent regime the Prandtl mixing length model was used. The numerical model involved the mass conservation, momentum conservation and mass transport equations coupled to the appropriate boundary conditions. In particular, as it is a numerical model, the discretization of convective terms was analyzed through the implementation of three schemes: WACEB, CUBISTA and adaptative QUICKEST. The results produced by the implementation of the convective schemes were analyzed through comparisons with experimental and analytical results from the literature, for laminar and turbulent flow regImes. According to the comparisons made, adaptative QUICKEST scheme showed the best performance in the modeling in this flow. Several numerical simulations generated results, which were compared with experimental data and analytical expressions of the literature and with data produced by the laboratory of the Center of Thermal Thermal and Fluids Engineering (NETeF) of the EESC- USP/São Cados. It was possible to verify, that the mathematical model produced results consistent with the phenomenon studied, and can be considered a tool for the description of the mass convective problem flow in permeavel tubes.

Page generated in 0.3316 seconds