• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • Tagged with
  • 6
  • 5
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Bactérias que degradam Monofluoroacetato de Sódio. / Bacteria Degrading Sodium Monofluoroacetate.

CAMBOIM, Expedito Kennedy Alves. 04 September 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-09-04T23:14:49Z No. of bitstreams: 1 EXPEDITO KENNEDY ALVES CAMBOIM - TESE PPGMV 2012..pdf: 1710872 bytes, checksum: c527311a481ea2baaf5080340bd08c0c (MD5) / Made available in DSpace on 2018-09-04T23:14:49Z (GMT). No. of bitstreams: 1 EXPEDITO KENNEDY ALVES CAMBOIM - TESE PPGMV 2012..pdf: 1710872 bytes, checksum: c527311a481ea2baaf5080340bd08c0c (MD5) Previous issue date: 2012-11-09 / O objetivo deste trabalho foi isolar e identificar bactérias capazes de degradar fluoroacetato de sódio (FS) em amostras de solo e plantas, coletadas em áreas onde são encontradas plantas que contêm fluoroacetato tais como Mascagnia rigida e Palicourea aenofusca. As amostras foram cultivadas em meio mineral acrescido de 20 mmol L−1 de fluoroacetato de sódio. Através do sequenciamento do gene 16S rRNA os sete isolados foram identificados como Paenibacillus sp. (ECPB01), Burkholderia sp. (ECPB02), Cupriavidus sp. (ECPB03), Staphylococcus sp. (ECPB04), Ancylobacter sp. (ECPB05), Ralstonia sp. (ECPB06), e Stenotrophomonas sp. (ECPB07). Todos os sete isolados degradaram o FS contido no meio, alcançando uma taxa de degradação de 20 mmol L−1 de íon flúor. Dos isolados, seis são descritos pela primeira vez como capazes de degradar FS. No futuro, alguns destes microorganismos podem ser utilizados para estabelecer no rúmen uma população bacteriana capaz de degradar o fluoroacetato de sódio e proteger ruminantes de intoxicações por este composto.
2

Avaliação dos efeitos tóxicos da Mascagnia rigida em ratos. Estudo anatomopatológico. Comparação entre metodologias cromatográficas para detecção do fluoroacetato de sódio / Evaluation of Mascagnia rigida toxics effects, in rats. Pathological study. Comparison of chromatographics methods for sodium fluoracetate detection

Cunha, Luciana Castro da 24 March 2008 (has links)
O fluoroacetato de sódio (FAS), também conhecido como \"composto 1080\", foi um raticida amplamente utilizado no combate de roedores a partir da década de 40, mas que teve seu uso proibido em diversos países, incluindo o Brasil, devido a sua alta toxicidade e ausência de tratamento efetivo nas intoxicações. A despeito deste fato, diversos casos de intoxicação ainda são registrados em seres humanos e animais, em virtude de seu uso ilícito como raticida doméstico ou adição em iscas nas intoxicações criminosas. O FAS, na natureza, pode ser encontrado, também, em algumas plantas tóxicas de grande importância no Brasil, como a Palicourea marcgravii, e possivelmente seja o princípio ativo tóxico de outras plantas de relevância, como a Mascagnia rigida. Neste sentido, este trabalho objetivou o estudo dos aspectos clínicos e anatomopatológicos encontrados nas intoxicações provocadas pelo FAS, em ratos, comparando estes com os encontrados nas intoxicações por extrato aquoso da M. rígida. Também foram comparadas metodologias analíticas para identificação deste agente tóxico utilizando cromatografia em camada delgada (CCD) e cromatografia de alta eficiência (CLAE) com dois tipos de detectores o de UV e o de Condutividade Iônica. Para tanto, quatro grupos contendo seis ratos Wistar, machos, receberam em dose única por via oral 7,0 mg/kg de FAS ou água destilada ou ainda 1,6 ou 3,2 g/kg de extrato aquoso de M. rígida, sendo avaliados os sinais clínicos apresentados por estes animais. Após eutanásia foram coletados fragmentos de cérebro, coração, fígado, rins, pulmão, intestino e baço para exame histopatológico. Tanto os animais que receberam FAS como os que receberam extrato aquoso de M. rígida apresentaram sintomatologia similar com presença de prostração, desconforto respiratório, tremores, pêlos arrepiados, cromodacriorreia, convulsão tônica e tônico-clônica. Na necropsia destes animais não foram observadas alterações macroscópicas, contudo alterações histopatológicas significativas foram encontradas no cérebro, miocárdio, fígado e rins. Os estudos das análise toxicológicas utilizando as três técnicas cromatográficas mostraram que os resultados obtidos na CCD foram adequados para detecção de FAS nas concentrações acima de 1,0 μg do padrão puro e as análises das duas plantas estudadas apresentaram resultados positivos para FAS. As técnicas utilizando CLAE, com dois diferentes detectores, mostraram que quando se utiliza detector de UV o limite de detecção é de 3,75 μg injetado ou de 75 μg/mL e foi possível, também, detectar a presença de FAS nas duas plantas estudadas, porém a técnica não se apresentou adequada para a detecção de intoxicação em tecido animal. O detector de condutividade iônica mostrou limite de detecção de 0,30 μg/mL, isto é, o mais sensível entre os três métodos estudados, e portanto o mais adequado para diagnóstico de intoxicação em tecido animal; no entanto, para identificação do FAS na M. rigida este método não se mostrou adequado devido a interferentes no extrato aquoso e no soro de animais intoxicados. / Sodium fluoroacetate (SFA), also known as \"compound 1080,\" was a rodenticide widely used in the 1940s, but its use was banned in several countries, including Brazil, for its high toxicity and lack of an effective treatment in poisoning. Despite this fact, several cases of poisoning are still registered in humans and animals, because of their misuse as baits, in addition to criminal poisoning. SFA, in the form of natural molecules, can be found in some toxic plants of great importance in Brazil, such as Palicourea marcgravii, and possibly is the active principle of other plants of relevance, such as Mascagnia rigid. Therefore, this study aimed to evaluate the clinical and pathological findings in poisoning caused by the SFA in rats, and compare them with those found in poisoning by the aqueous extract of M. rigid. Moreover, we compared analytical methods for identifying this toxic agent using thin layer chromatography (TLC) and high performance liquid chromatography (HPLC) employing two types of detectors: ultraviolet (UV) and ionic conductivity. Therefore, four groups containing six male Wistar rats each, received a single oral dose of 7.0 mg / kg of SFA, an equal volume of distilled water, or 1.6 or 3.2 g / kg of an aqueous extract of M. rigid, and the clinical signs displayed by these animals were evaluated. After euthanasia fragments of brain, heart, liver, kidney, lung, intestine and spleen were collected for histological examination. Both the animals that received SFA and those who received the aqueous extract of M. rigid showed similar symptoms, including prostration, respiratory distress, tremors, shivering, and tonic or tonic-clonic seizures. At necropsy, these animals did not display macroscopic changes. Nevertheless, significant histopathological changes were found in the brain, heart, liver and kidneys. Toxicological analysis using the three chromatographic techniques described above showed that the results obtained in the TLC were suitable for detection of SFA at concentrations above 1.0 μg of pure standard, and analysis of the two plants mentioned showed positive results for SFA. The techniques using HPLC with two different detectors showed that when using the UV detector, the detection limit is of 3.75 μg (injected) or 75 μg / mL, and SFA could also be detected by these methods in the two plants studied, but the technique does not seem suitable for the detection of intoxication in animal tissue samples. The ionic conductivity detector showed a detection limit of 0.30 μg/ mL, therefore the most sensitive of the three methods studied, and hence is the most appropriate for diagnosis of poisoning in animal tissue; however, for the identification of SFA in the M. rigid, this method was not appropriate due to a putative interference in the aqueous extract.
3

Avaliação dos efeitos tóxicos da Mascagnia rigida em ratos. Estudo anatomopatológico. Comparação entre metodologias cromatográficas para detecção do fluoroacetato de sódio / Evaluation of Mascagnia rigida toxics effects, in rats. Pathological study. Comparison of chromatographics methods for sodium fluoracetate detection

Luciana Castro da Cunha 24 March 2008 (has links)
O fluoroacetato de sódio (FAS), também conhecido como \"composto 1080\", foi um raticida amplamente utilizado no combate de roedores a partir da década de 40, mas que teve seu uso proibido em diversos países, incluindo o Brasil, devido a sua alta toxicidade e ausência de tratamento efetivo nas intoxicações. A despeito deste fato, diversos casos de intoxicação ainda são registrados em seres humanos e animais, em virtude de seu uso ilícito como raticida doméstico ou adição em iscas nas intoxicações criminosas. O FAS, na natureza, pode ser encontrado, também, em algumas plantas tóxicas de grande importância no Brasil, como a Palicourea marcgravii, e possivelmente seja o princípio ativo tóxico de outras plantas de relevância, como a Mascagnia rigida. Neste sentido, este trabalho objetivou o estudo dos aspectos clínicos e anatomopatológicos encontrados nas intoxicações provocadas pelo FAS, em ratos, comparando estes com os encontrados nas intoxicações por extrato aquoso da M. rígida. Também foram comparadas metodologias analíticas para identificação deste agente tóxico utilizando cromatografia em camada delgada (CCD) e cromatografia de alta eficiência (CLAE) com dois tipos de detectores o de UV e o de Condutividade Iônica. Para tanto, quatro grupos contendo seis ratos Wistar, machos, receberam em dose única por via oral 7,0 mg/kg de FAS ou água destilada ou ainda 1,6 ou 3,2 g/kg de extrato aquoso de M. rígida, sendo avaliados os sinais clínicos apresentados por estes animais. Após eutanásia foram coletados fragmentos de cérebro, coração, fígado, rins, pulmão, intestino e baço para exame histopatológico. Tanto os animais que receberam FAS como os que receberam extrato aquoso de M. rígida apresentaram sintomatologia similar com presença de prostração, desconforto respiratório, tremores, pêlos arrepiados, cromodacriorreia, convulsão tônica e tônico-clônica. Na necropsia destes animais não foram observadas alterações macroscópicas, contudo alterações histopatológicas significativas foram encontradas no cérebro, miocárdio, fígado e rins. Os estudos das análise toxicológicas utilizando as três técnicas cromatográficas mostraram que os resultados obtidos na CCD foram adequados para detecção de FAS nas concentrações acima de 1,0 μg do padrão puro e as análises das duas plantas estudadas apresentaram resultados positivos para FAS. As técnicas utilizando CLAE, com dois diferentes detectores, mostraram que quando se utiliza detector de UV o limite de detecção é de 3,75 μg injetado ou de 75 μg/mL e foi possível, também, detectar a presença de FAS nas duas plantas estudadas, porém a técnica não se apresentou adequada para a detecção de intoxicação em tecido animal. O detector de condutividade iônica mostrou limite de detecção de 0,30 μg/mL, isto é, o mais sensível entre os três métodos estudados, e portanto o mais adequado para diagnóstico de intoxicação em tecido animal; no entanto, para identificação do FAS na M. rigida este método não se mostrou adequado devido a interferentes no extrato aquoso e no soro de animais intoxicados. / Sodium fluoroacetate (SFA), also known as \"compound 1080,\" was a rodenticide widely used in the 1940s, but its use was banned in several countries, including Brazil, for its high toxicity and lack of an effective treatment in poisoning. Despite this fact, several cases of poisoning are still registered in humans and animals, because of their misuse as baits, in addition to criminal poisoning. SFA, in the form of natural molecules, can be found in some toxic plants of great importance in Brazil, such as Palicourea marcgravii, and possibly is the active principle of other plants of relevance, such as Mascagnia rigid. Therefore, this study aimed to evaluate the clinical and pathological findings in poisoning caused by the SFA in rats, and compare them with those found in poisoning by the aqueous extract of M. rigid. Moreover, we compared analytical methods for identifying this toxic agent using thin layer chromatography (TLC) and high performance liquid chromatography (HPLC) employing two types of detectors: ultraviolet (UV) and ionic conductivity. Therefore, four groups containing six male Wistar rats each, received a single oral dose of 7.0 mg / kg of SFA, an equal volume of distilled water, or 1.6 or 3.2 g / kg of an aqueous extract of M. rigid, and the clinical signs displayed by these animals were evaluated. After euthanasia fragments of brain, heart, liver, kidney, lung, intestine and spleen were collected for histological examination. Both the animals that received SFA and those who received the aqueous extract of M. rigid showed similar symptoms, including prostration, respiratory distress, tremors, shivering, and tonic or tonic-clonic seizures. At necropsy, these animals did not display macroscopic changes. Nevertheless, significant histopathological changes were found in the brain, heart, liver and kidneys. Toxicological analysis using the three chromatographic techniques described above showed that the results obtained in the TLC were suitable for detection of SFA at concentrations above 1.0 μg of pure standard, and analysis of the two plants mentioned showed positive results for SFA. The techniques using HPLC with two different detectors showed that when using the UV detector, the detection limit is of 3.75 μg (injected) or 75 μg / mL, and SFA could also be detected by these methods in the two plants studied, but the technique does not seem suitable for the detection of intoxication in animal tissue samples. The ionic conductivity detector showed a detection limit of 0.30 μg/ mL, therefore the most sensitive of the three methods studied, and hence is the most appropriate for diagnosis of poisoning in animal tissue; however, for the identification of SFA in the M. rigid, this method was not appropriate due to a putative interference in the aqueous extract.
4

Desenvolvimento do radiofármaco 18F-acetato para a detecção de tumores primários através do PET/CT / Development of the radiopharmaceutical 18F-acetate for detection of primary tumours through PET/CT

Larissa Gomes de Carvalho 27 September 2012 (has links)
A tomografia por emissão de pósitrons associada à tomografia computadorizada (PET/CT) é um dispositivo que combina as características de medicina nuclear (PET) e de radiologia (CT) obtendo imagens metabólicas (PET) e anatômicas sobrepostas (CT). Combinando as duas tecnologias de exames, o exame PET / CT permite aos médicos diagnosticar com maior precisão e identificar o câncer, doenças cardíacas e distúrbios cerebrais. O radiofármaco 18FFAc (fluoroacetato) é promissor para a detecção de tumores primários de próstata e de mama, utilizando a técnica de PET/CT. Estudos recentes mostram a eficácia do 18F-FAc na detecção de tumores que têm baixa captação de 18F-FDG (fluordesoxiglicose). O fluoroacetato é um substrato para a acetil-CoA sintase, enzima que metaboliza ácido fluorocitrato que não é mais metabolizado, levando à inibição da aconitase e do ácido tricarboxílico. O objetivo deste trabalho foi desenvolver um radiofármaco emissor de pósitron, 18F-FAc no IPEN-CNEN/SP em um acordo com o Hospital AC-Camargo / São Paulo. O íon fluoreto (18F-) foi produzido, usando os cíclotrons Cyclone 30 e 18 da IBA localizados no IPEN-CNEN/SP, através da irradiação de água enriquecida em 18O com prótons e dose integrada de 30μAh. A marcação do 18F-FAc foi realizada em um módulo de síntese TRACERlab MXFDG (GE), utilizando kits adquiridos da ABX. O controle de qualidade radioquímico de 18F-FAc foi realizado por cromatografia em camada fina TLC-SG 25 folhas de alumínio em tiras (1,5 x 12 cm ) usando como solvente clorofórmio:metanol (1:1). Para o controle de qualidade radionuclídico, amostras de 18F-FAc e 18F-Fluoreto foram analisadas por espectroscopia de raios-gama. A avaliação dos solventes residuais foi realizada por cromatografia em fase gasosa e a análise de kryptofix foi realizada por TLC utilizando tiras de TLC-SG, metanol:clorofórmio (9:1) como solvente e padrões de kryptofix 2.2.2. Os estudos de biodistribuição foram realizados com 18FFAc injetado em camundongos swiss sadios. Um procedimento reprodutível foi desenvolvido para o preparo do 18F-FAc com um rendimento de marcação de 37% (não corrigido) e 52% (corrigido para o decaimento) e estabilidade de 19 horas. A análise de controle de qualidade mostrou que o produto tinha as exigências adequadas para utilização, com pureza radioquímica superior a 99,9%. Os estudos de biodistribuição em animais sadios mostraram a esperada captação em todos os órgãos medidos com eliminação renal e intestinal. / PET / CT (positron emission tomography / computed tomography) is a device that combines the features of diagnostic nuclear medicine (PET) and Radiology (CT) superimposing metabolic (PET) and anatomical (CT) images. By combining the two technologies examinations, the PET/CT scan allows physicians to diagnose more accurately and identify cancer, heart disease and brain disorders. The radiopharmaceutical 18F-FAc (fluoroacetate) is promising for application in detection of primary tumors of prostate and breast, using PET-CT techniques. Recent studies are showing the efficacy of the 18F-FAc in the detection of tumors that have low uptake of 18F-FDG (fluorodeoxyglucose). The fluoroacetate is a substrate for the enzyme acetyl-CoA synthase that metabolizes acid fluorcitric that, not being metabolized, causes inhibition of aconitase and inhibition of tricarboxylic acid. The aim of this work was to develop a positron emitting radiopharmaceutical, 18F-FAc at IPEN-CNEN/SP in agreement with Hospital AC-Camargo/ São Paulo. The 18F-fluoride ion was produced using the Cyclone 30 and 18 cyclotrons from IBA located at IPEN-CNEN/SP, by irradiating enriched 18O water with protons with integrated dose 30μAh. The labelling of 18F-FAc was performed in a synthesis module TRACERlab MXFDG (GE), using kits purchased from ABX. The radiochemical quality control of 18F-FAc was performed by Thin Layer Chromatography using TLC-SG 25 aluminium sheets strips (1.5 x 12 cm) and chloroform:methanol (1:1) as the solvent. For the radionuclidic quality control, samples of 18F-FAc and 18F-Fluoride were analysed by gama-ray spectroscopy. The evaluation of the residual solvents was performed by gas chromatography and the analysis of kryptofix was performed by TLC using TLC-SG strips, methanol:chloroform (9:1) as solvent and kryptofix 2.2.2 standards. Biodistribution studies were performed with 18F-FAc injected into healthy Swiss mice. A reliable procedure was developed for preparation of 18F-FAc with a labelling yield of 37% (uncorrected) and 52% (corrected for decay) and stability of 19 hours. The quality control analysis showed that the product had the proper requirements for use, with radiochemical purity exceeding 99.9%. The biodistribution studies in healthy animals showed the expected uptake results in all the measured organs with intestinal and renal elimination.
5

Desenvolvimento do radiofármaco 18F-acetato para a detecção de tumores primários através do PET/CT / Development of the radiopharmaceutical 18F-acetate for detection of primary tumours through PET/CT

Carvalho, Larissa Gomes de 27 September 2012 (has links)
A tomografia por emissão de pósitrons associada à tomografia computadorizada (PET/CT) é um dispositivo que combina as características de medicina nuclear (PET) e de radiologia (CT) obtendo imagens metabólicas (PET) e anatômicas sobrepostas (CT). Combinando as duas tecnologias de exames, o exame PET / CT permite aos médicos diagnosticar com maior precisão e identificar o câncer, doenças cardíacas e distúrbios cerebrais. O radiofármaco 18FFAc (fluoroacetato) é promissor para a detecção de tumores primários de próstata e de mama, utilizando a técnica de PET/CT. Estudos recentes mostram a eficácia do 18F-FAc na detecção de tumores que têm baixa captação de 18F-FDG (fluordesoxiglicose). O fluoroacetato é um substrato para a acetil-CoA sintase, enzima que metaboliza ácido fluorocitrato que não é mais metabolizado, levando à inibição da aconitase e do ácido tricarboxílico. O objetivo deste trabalho foi desenvolver um radiofármaco emissor de pósitron, 18F-FAc no IPEN-CNEN/SP em um acordo com o Hospital AC-Camargo / São Paulo. O íon fluoreto (18F-) foi produzido, usando os cíclotrons Cyclone 30 e 18 da IBA localizados no IPEN-CNEN/SP, através da irradiação de água enriquecida em 18O com prótons e dose integrada de 30μAh. A marcação do 18F-FAc foi realizada em um módulo de síntese TRACERlab MXFDG (GE), utilizando kits adquiridos da ABX. O controle de qualidade radioquímico de 18F-FAc foi realizado por cromatografia em camada fina TLC-SG 25 folhas de alumínio em tiras (1,5 x 12 cm ) usando como solvente clorofórmio:metanol (1:1). Para o controle de qualidade radionuclídico, amostras de 18F-FAc e 18F-Fluoreto foram analisadas por espectroscopia de raios-gama. A avaliação dos solventes residuais foi realizada por cromatografia em fase gasosa e a análise de kryptofix foi realizada por TLC utilizando tiras de TLC-SG, metanol:clorofórmio (9:1) como solvente e padrões de kryptofix 2.2.2. Os estudos de biodistribuição foram realizados com 18FFAc injetado em camundongos swiss sadios. Um procedimento reprodutível foi desenvolvido para o preparo do 18F-FAc com um rendimento de marcação de 37% (não corrigido) e 52% (corrigido para o decaimento) e estabilidade de 19 horas. A análise de controle de qualidade mostrou que o produto tinha as exigências adequadas para utilização, com pureza radioquímica superior a 99,9%. Os estudos de biodistribuição em animais sadios mostraram a esperada captação em todos os órgãos medidos com eliminação renal e intestinal. / PET / CT (positron emission tomography / computed tomography) is a device that combines the features of diagnostic nuclear medicine (PET) and Radiology (CT) superimposing metabolic (PET) and anatomical (CT) images. By combining the two technologies examinations, the PET/CT scan allows physicians to diagnose more accurately and identify cancer, heart disease and brain disorders. The radiopharmaceutical 18F-FAc (fluoroacetate) is promising for application in detection of primary tumors of prostate and breast, using PET-CT techniques. Recent studies are showing the efficacy of the 18F-FAc in the detection of tumors that have low uptake of 18F-FDG (fluorodeoxyglucose). The fluoroacetate is a substrate for the enzyme acetyl-CoA synthase that metabolizes acid fluorcitric that, not being metabolized, causes inhibition of aconitase and inhibition of tricarboxylic acid. The aim of this work was to develop a positron emitting radiopharmaceutical, 18F-FAc at IPEN-CNEN/SP in agreement with Hospital AC-Camargo/ São Paulo. The 18F-fluoride ion was produced using the Cyclone 30 and 18 cyclotrons from IBA located at IPEN-CNEN/SP, by irradiating enriched 18O water with protons with integrated dose 30μAh. The labelling of 18F-FAc was performed in a synthesis module TRACERlab MXFDG (GE), using kits purchased from ABX. The radiochemical quality control of 18F-FAc was performed by Thin Layer Chromatography using TLC-SG 25 aluminium sheets strips (1.5 x 12 cm) and chloroform:methanol (1:1) as the solvent. For the radionuclidic quality control, samples of 18F-FAc and 18F-Fluoride were analysed by gama-ray spectroscopy. The evaluation of the residual solvents was performed by gas chromatography and the analysis of kryptofix was performed by TLC using TLC-SG strips, methanol:chloroform (9:1) as solvent and kryptofix 2.2.2 standards. Biodistribution studies were performed with 18F-FAc injected into healthy Swiss mice. A reliable procedure was developed for preparation of 18F-FAc with a labelling yield of 37% (uncorrected) and 52% (corrected for decay) and stability of 19 hours. The quality control analysis showed that the product had the proper requirements for use, with radiochemical purity exceeding 99.9%. The biodistribution studies in healthy animals showed the expected uptake results in all the measured organs with intestinal and renal elimination.
6

A inoculação ruminal de Enterococcus faecalis é eficiente no controle da intoxicação por monofluoroacetato de sódio em ovinos?

Dias, Geovanny Bruno Gonçalves 03 March 2015 (has links)
Submitted by Jordan (jordanbiblio@gmail.com) on 2017-10-04T14:12:15Z No. of bitstreams: 1 DISS_2015_Geovanny Bruno Gonçalves Dias.pdf: 1405701 bytes, checksum: 24fbe33b137779f7f8668a0dfcb69dd5 (MD5) / Approved for entry into archive by Jordan (jordanbiblio@gmail.com) on 2017-10-04T14:12:38Z (GMT) No. of bitstreams: 1 DISS_2015_Geovanny Bruno Gonçalves Dias.pdf: 1405701 bytes, checksum: 24fbe33b137779f7f8668a0dfcb69dd5 (MD5) / Made available in DSpace on 2017-10-04T14:12:38Z (GMT). No. of bitstreams: 1 DISS_2015_Geovanny Bruno Gonçalves Dias.pdf: 1405701 bytes, checksum: 24fbe33b137779f7f8668a0dfcb69dd5 (MD5) Previous issue date: 2015-03-03 / CAPES / CNPq / Do grupo das plantas que causa morte súbita em animais de interesse pecuário no Brasil, sete delas contém monofluoroacetato de sódio (MFA) como princípio tóxico. MFA causa bloqueio do ciclo de Krebs e consequente acúmulo de citrato nos tecidos. A movimentação dos animais intoxicados desencadeia os sinais clínicos e a morte com evolução superaguda. Uma das alternativas preconizadas para prevenção da intoxicação é a ingestão de doses não tóxicas de plantas que contém MFA. Sugere-se que a resistência ocorra devido à multiplicação de microrganismos que expressam o gene fluoroacetato dehalogenase e degradam o MFA no rúmen. Este estudo teve por objetivo verificar se E. faecalis EF09, JQ661270.1 e E. faecalis EF08, JQ661271.1, isoladas do rúmen de bovinos, degradam MFA in vivo e podem ser usadas para detoxificação de plantas que contém MFA. Para a realização deste experimento, seis ovinos com idade média de dois anos, fêmeas, entre 35-40 kg, de raça Santa Inês, foram divididos em dois grupos com três animais cada. O Grupo Inoculação recebeu durante três dias seguidos o inóculo de E. faecalis de 30 ml dividido em três doses de 10 ml. O Grupo Controle recebeu água destilada durante o mesmo período. Os animais de ambos os grupos foram mantidos em descanso por 48 horas e após esse período, o MFA foi fornecido em uma dose de 1,5 mg/Kg/PV por via oral para todos os ovinos. Os sinais clínicos, frequência cardíaca e respiratória foram obtidos em repouso a cada uma hora, e após 10 minutos de movimentação decorridas seis horas da intoxicação. Todos os animais de ambos os grupos morreram entre três e oito horas após o fornecimento de MFA. Os resultados indicam que os animais não desenvolveram resistência ao MFA após a inoculação com E. faecalis. / From the group of plants that cause sudden death in livestock in Brazil, seven of which contains sodium fluoroacetate (MFA) as toxic principle. MFA cause blockage of the Krebs cycle and subsequent accumulation of citrate in the tissues. The movement of animals that are intoxicated triggers the clinical signs and cause the death with acute evolution. One envisaged alternative to preventing poisoning is the ingestion of nontoxic doses of plants containing the MFA. It is suggested that the resistance occurs due to proliferation of microorganisms that express the MFA degrading gene fluoroacetate dehalogenase and that the MFA is degrade in the rumen. This study aimed to determine whether E. faecalis FY09, JQ661270.1 and FY08, JQ661271.1, isolated from bovine rumen, degrade MFA in vivo and can be used for detoxification of plants containing MFA. To carry out this experiment, six sheep with an average age of two years old, female, between 35-40 kg, Santa Ines, were divided into two groups of three animals each. The inoculation Group received for three consecutive days, E. faecalis - 30 ml inoculum divided into three doses of 10 ml. The control group received distilled water for the same period. The animals of both groups were kept at rest for 48 hours and after this period, the MFA is provided in a dose of 1.5 mg / kg / Live Weight orally to all sheep. Clinical signs, heart and respiratory rate were obtained at rest every hour, and after 10 minutes of elapsed drive six hours of poisoning. All animals in both groups died between three and eight hours after delivery of MFA. The results indicate that the animals have not developed resistance to MFA after inoculation with E. faecalis.

Page generated in 0.0626 seconds