• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 46
  • 2
  • 1
  • Tagged with
  • 50
  • 50
  • 30
  • 29
  • 26
  • 20
  • 17
  • 15
  • 14
  • 13
  • 10
  • 10
  • 10
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Aplicação do modelo QTAIM/CCFDF para o estudo de estruturas eletrônicas dos clorofluorometanos / Application of the QTAIM/CCFDF model for the study of electronic structures for chlorofluoromethanes

Silva Filho, Arnaldo Fernandes da, 1987- 18 August 2018 (has links)
Orientador: Roy Edward Bruns / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Química / Made available in DSpace on 2018-08-18T09:29:34Z (GMT). No. of bitstreams: 1 SilvaFilho_ArnaldoFernandesda_M.pdf: 1712165 bytes, checksum: ba65ba1932c8a6baa99b265fd3d6770d (MD5) Previous issue date: 2011 / Resumo: Foram calculadas as intensidades fundamentais vibracionais no infravermelho e as contribuições QTAIM/CCFDF do tensor polar atômico, nos níveis MP2/6-311++G(3d,3p) e QCISD/cc-pVTZ, para os clorofluorometanos. Um erro rms de 21,2 km/mol foi encontrado entre as intensidades experimentais e as obtidas no nível MP2/6-311++G(3d,3p), e 20,0 km/mol, entre as intensidades experimentais e as obtidas no nível QCISD/cc-pVTZ. O erro rms encontrado entre as intensidades obtidas das funções de onda e as calculadas através dos parâmetros QTAIM/CCFDF foi de 0,016 km/mol para o nível MP2/6-311++G(3d,3p), e 0,018 km/mol para o nível QCISD/cc-pVTZ. O erro para os elementos do tensor polar atômico e derivada média do momento dipolar entre os níveis QCISD/cc-pVTZ, MP2/6-311++G(3d,3p) e os valores experimentais foi da ordem de 0,06 u.a. Apesar do bom resultado para a derivada média do momento dipolar, as contribuições CCFDF não foram calculadas com a mesma exatidão. Apenas os fluorometanos parecem ter estruturas eletrônicas que se ajustam ao modelo simples de eletronegatividade. o átomo de flúor não tem sua capacidade de atrair os elétrons do átomo central saturada, enquanto a carga efetiva do cloro parece depender da quantidade e identidade dos demais átomos substituintes. Esse efeito de saturação separa as moléculas estudadas em três grupos: fluorometanos, clorometanos e clorofluorometanos. As derivadas médias do momento dipolar seguem melhor o modelo de Siegbahn do que cargas de fluxo zero, apesar contribuições dinâmicas que não se anulam completamente. A regra da soma para as derivadas médias do momento dipolar se mostrou eficiente para o átomo de carbono. Os átomos terminais não tiveram a mesma precisão para a regra da soma. A anisotropia calculada no nível QCISD/cc-pVTZ, teve um concordância superior com os valores experimentais, quando comparada com valores do nível MP2/6-311++G(3d,3p) / Abstract: The infrared fundamental intensities and QTAIM/CCFDF contributions to the atomic polar tensor were calculated at MP2/6-311++G(3d, 3p) and QCISD/cc-pVTZ levels, for the chlorofluoromethanes. A rms error of 21.2 km/mol was obtained between experimental and MP2/6-311++G(3d, 3p) intensities. The rms error between experimental and QCISD/cc-pVTZ intensities was 20.0 km/mol. The rms error found between intensities obtained directly from the wave functions and calculated through QTAIM/CCFDF parameters was 0.016 km/mol for the MP2/6-311++G(3d, 3p) level, and 0.018 km/mol for the QCISD/cc-pVTZ level. The error between the theoretical atomic polar tensor elements and mean dipole moment derivatives compared to experimental values is about 0.06 a.u. Despite good results for the mean dipole moment derivatives, the CCFDF contributions have not been calculated with the same accuracy. The fluoromethanes seem to be the only group whose electronic structures fit the simple electronegativity model. The fluorine atom does not has its ability to drain charge from the central atom altered, while the chlorine effective charge seems to depend on the number and identity of other terminal atoms. This saturating effect separates the studied molecules in three groups: fluoromethanes, chloromethane and chlorofluoromethanes. Mean dipole moment derivatives have a better fit to Siegbahn¿s model than zero-flux charges, beside to their dynamic contributions. The sum rule for mean dipole moment derivatives was efficient for the carbon atom. Terminal atoms did not have the same accuracy for the sum rule. QCISD/cc-pVTZ anisotropy values were closer to experimental values, when compared to the MP2/6-311++G(3d, 3p) level / Mestrado / Físico-Química / Mestre em Química
32

Aplicação do modelo carga-fluxo de dipolo para calcular e interpretar as intensidades no espectro infravermelho dos fluoroclorometanos / Application of the charge-charge flux-dipole model to calculate and interpret the infrared intensities of the fluorochlorolethanes

Silva Junior, João Viçozo 07 December 2006 (has links)
Orientador: Roy Edward Bruns / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-09T10:57:29Z (GMT). No. of bitstreams: 1 SilvaJunior_JoaoVicozo_M.pdf: 455136 bytes, checksum: d8cb42bcd5d75c3d6dd417771ba11425 (MD5) Previous issue date: 2007 / Resumo: O momento dipolar molecular, suas derivadas e as intensidades fundamentais no espectro infravermelho dos fluoroclorometanos são determinados a partir de cargas e dipolos atômicos QTAIM, e de seus fluxos no nível MP2/6-311++G(3d,3p). A comparação dos momentos dipolares e das intensidades fundamentais no infravermelho calculados usando parâmetros QTAIM com aqueles obtidos diretamente a partir de cálculos MP2/6-311++G(3d,3p) mostra erros rms (root mean square) de 0,01 D e 5,6 km mol, e erros de 0,04 D e 23,1 km mol quando comparados com valores experimentais. As contribuições de carga, fluxo de carga e fluxo de dipolo são calculadas para todos os modos normais de vibração destas moléculas. Uma correlação negativa significativa (-0,92) é observada entre as contribuições de fluxo de carga e de fluxo de dipolo e indica que a transferência de carga de um lado para outro da molécula durante as vibrações é acompanhada por uma relaxação da densidade eletrônica que se polariza na direção oposta. Os modos normais de estiramento CF, CCl e CH destas moléculas mostram ter conjuntos de valores característicos de contribuições de carga, fluxo de carga e fluxo de dipolo. Embora as deformações FCF e ClCCl também possam ser diferenciadas umas das outras a partir dos tamanhos e sinais destas contribuições, algumas deformações HCH têm contribuições que são parecidas com aquelas das deformações ClCCl / Abstract: The molecular dipole moments, their derivatives and the fundamental infrared intensities of the fluorochloromethanes are determined from QTAIM atomic charges and dipoles and their fluxes at the MP2/6- 311++G(3d,3p) level. Root-mean-square (rms) errors of 0.01 D and 5.6 km mol are found for the dipole moments and fundamental infrared intensities calculated using QTAIM parameters when compared with those obtained directly from the MP2/6-311++(3d,3p) calculations and 0.04 D and 23.1 km mol when compared to the experimental values. Charge, charge flux and dipole flux contributions are calculated for all the normal vibrations of these molecules. A large negative correlation coefficient of -0.92 is calculated between the charge flux and dipole flux contributions and indicates that charge transfer from one side of the molecule to the other during vibrations is accompanied by relaxation with electron density polarization in the opposite direction. The CF, CCl and CH stretching normal modes of these molecules are shown to have characteristic sets of charge, charge flux and dipole flux contributions. Although the FCF and ClCCl deformation normal modes can also be discriminated from one another based on their sizes and signs of these contributions some HCH deformations have contributions that are similar to those for some of the ClCCl deformations / Mestrado / Físico-Química / Mestre em Química
33

Utilização do modelo CCFDF na interpretação das intensidades fundamentais das moleculas 'X IND. 2 CY' e sua aplicação na regra da soma / Use of the CCFDF model in the interpretation of the fundamental intensities of the 'X IND. 2 CY' molecules and its application in characteristic substituent shift model

Faria, Sergio Henrique Dias Marques 14 April 2008 (has links)
Orientador: Roy Edward Bruns / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-11T06:56:00Z (GMT). No. of bitstreams: 1 Faria_SergioHenriqueDiasMarques_M.pdf: 997317 bytes, checksum: c659ee21fc8d6bfbdf14b0418bd6b99b (MD5) Previous issue date: 2008 / Resumo: Foram determinadas as cargas e dipolos atômicos QTAIM, a partir das geometrias otimizadas das moléculas X2CY (X = H, F, Cl; Y = O, S). Com esses dados, foram calculados os momentos de dipolo molecular dessas moléculas, que apresentaram uma boa concordância com os valores experimentais disponíveis na literatura e com os calculados diretamente pela função de onda MP2/6-311++G (3d, 3p). Também foram calculadas as intensidades fundamentais do infravermelho das moléculas X2CY que tiveram boa concordância com as intensidades fundamentais experimentais já publicadas, além daquelas obtidas com a função de onda MP2. Com as derivadas médias do momento dipolar das moléculas X2CY decompostas em contribuições de carga ¿ fluxo de carga ¿ fluxo de dipolo foi verificada a validade da regra da soma (CSSM - Characteristic Substituent-Shift Model) para essas três contribuições. Os resultados indicaram boa concordância da regra da soma em relação aos resultados obtidos pelo modelo CCFDF/QTAIM para todas as contribuições. A regra da soma para as contribuições CCFDF das derivadas médias do momento dipolar das moléculas CnHm, CHnXm (X= F, Cl), CFnClm, CX2 (X = S, O) e CX4 (X = F, Cl) também foi testada. Observouse que as contribuições de carga tiveram uma melhor concordância com as do modelo CCFDF/QTAIM do que as dos fluxos para o átomo de carbono. Já, para os átomos terminais dessas moléculas, a regra da soma mostrou-se inválida para o cálculo das derivadas médias do momento dipolar. Finalmente, a comparação entre os programas Gaussian 98 com o Morphy mostrou que ambos os programas são igualmente eficientes / Abstract: The QTAIM atomic charges and dipoles of X2CY (X = H, F, Cl; Y = O, S) molecules were determined from their optimized geometries. With these data the molecular dipole moments were calculated, showing good agreement with the experimental values in the literature and with the calculated values from the MP2/6-311++G (3d, 3p) wavefunction. The infrared fundamental intensities of the X2CY molecules were calculated and presented good agreement with experimental results already published and also with those obtained with the MP2 wavefunction. With the mean dipole moment derivatives of X2CY molecules decomposed into charge ¿ charge flux ¿ dipole flux contributions, the validity of the Characteristic Substituent Shift Model (CSSM) was verified for these three contributions. The results indicated good agreement of the CSSM in relation to the results obtained from the CCFDF/QTAIM model for all contributions. The CSSM for CCFDF contributions of the mean dipole moment derivatives of the CnHm, CHnXm (X= F, Cl), CFnClm, CX2 (X = S, O) e CX4 (X = F, Cl) molecules was also tested. The charge contributions showed better agreement with the ones of the CCFDF/QTAIM model than did the flux contributions for the carbon atom. For terminal atoms of theses molecules, the CSSM was not valid for the calculation of the mean dipole moment derivatives. Finally, comparison between results of the Gaussian 98 and Morphy programs showed that both are equally efficient for these X2CY molecules / Mestrado / Físico-Química / Mestre em Química
34

Cálculo das soluções de baixa tensão das equações de fluxo de carga através de sistemas dinâmicos auxiliares e função energia estendida com modelo ZIP para análise de colapso de tensão / not available

Renato Braga de Lima Guedes 27 May 2004 (has links)
Este trabalho está dividido em duas partes distintas que constituem contribuições inéditas ao estudo da estabilidade em sistemas elétricos de potência. A primeira parte do trabalho é a mais importante e trata do problema da identificação das soluções de baixa tensão críticas do fluxo de carga. Esta parte do trabalho se presta a análise de estabilidade de tensão a pequenas perturbações. Os últimos capítulos deste trabalho apresentam também uma proposta de função energia estendida que modela as cargas dependentes da tensão segundo o modelo ZIP de carga, considerando a estrutura da rede preservada. Assim, a função energia proposta pode ser utilizada para analisar tanto a estabilidade de tensão como a estabilidade de ângulo em sistemas de potência. Esta proposta também é inédita na literatura. Embora a função energia proposta tenha sido aplicada apenas a sistemas de dimensão reduzidas, os resultados apresentados neste trabalho nos levam a acreditar que essa mesma função energia pode ser utilizada na análise de estabilidade de sistemas de potência de grandes dimensões. Já o método proposto para identificação das soluções de baixa tensão das equações de fluxo de carga se utiliza de um sistema dinâmico auxiliar das equações de fluxo de carga. O sistema dinâmico auxiliar utilizado não tem significado físico, mas pode ser escolhido de tal forma que a solução usual das equações de fluxo de carga seja um ponto de equilíbrio estável do sistema dinâmico auxiliar, eque as soluções de baixa tensão do fluxo de carga sejam pontos de equilíbrio instáveis do sistema dinâmico auxiliar. Dessa forma, é possível calcular as soluções de baixa tensão do fluxo de carga, calculando-se os pontos de equilíbrio instáveis do sistema dinâmico auxiliar. Assim, é possível utilizar partes da teoria de sistemas dinâmicos para estudar as soluções das equações de fluxo de carga. Baseado nestes princípios, foi desenvolvido um programa para calcular trajetórias do sistema dinâmico auxiliar, que se iniciam e se mantêm nas vizinhanças da fronteira da área de atração do ponto de equilíbrio estável do SEP. Dessa forma é possível afirmar que a trajetória calculada tende a convergir para a solução crítica das equações de fluxo de carga. O programa foi inicialmente concebido para calcular as soluções de baixa tensão de sistemas elétricos sem perdas. Em seguida o programa desenvolvido foi adaptado para calcular as soluções de baixa tensão de sistemas de potência completos, incluindo também as resistências das linhas de transmissão. Esta última versão do programa foi testada para os sistemas IEEE 39 e IEEE 118 barras, e os resultados obtidos se mostraram bastante satisfatórios. Assim, o método proposto é uma ferramenta original e eficaz para a solução do problema de calcular a solução crítica das equações de fluxo de carga de sistemas elétricos de potência. / This work may be divided into two distinct parts. Both of them are new contributions to stability analysis of power systems. In the first part it is proposed a new method to calculate the critical load flow low voltage solutions, and it is the main part of this work. Meanwhile, the last two chapters of this work presents a proposed extended energy function that consider the common load ZIP models. It allows the analysis of angle and voltage stability for power systems subjected to large disturbances. This work proposes a method to calculate the low voltage solutions (LVS) of the load flow equations of an electrical power system. The proposed method identifies the LVS involved in the saddle-node bifurcation leading the power system to a voltage collapse. This solution is known as the critical low voltage solution. In order to perform the proposed calculation, an auxiliary dynamical gradient system is used. It is shown that the equilibrium points of that associated auxiliary dynamical gradient system are the solutions of the load flow equations. In such manner, the paper proposes identifying the critical LVS calculating the equilibrium points of an auxiliary dynamical gradient system. The proposed method was tested on the Stagg 5-bus, on the IEEE 39-bus and on IEEE 118-bus test systems, and the results are presented at the end of the text.
35

Aprimoramento do modelo QTAIM/CCFDF : como descrever a vibração de moléculas / Improving the QTAIM/CCFDF : describing molecular vibrations

Silva Filho, Arnaldo Fernandes da, 1987- 25 February 2015 (has links)
Orientador: Roy Edward Bruns / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Química / Made available in DSpace on 2018-08-27T17:55:48Z (GMT). No. of bitstreams: 1 SilvaFilho_ArnaldoFernandesda_D.pdf: 3082631 bytes, checksum: e9ba02a9f689d66f518049735ac3117b (MD5) Previous issue date: 2015 / Resumo: No que diz respeito aos clorofluorometanos, os estiramentos e deformações C-F têm cargas atômicas que fornecem as contribuições dominantes para as intensidades totais, ainda que as suas interações com os fluxos de carga e de dipolo sejam importantes. A soma das contribuições de carga com estas interações permite estimativas muito precisas para as intensidades dos estiramentos C-F. Para os estiramentos e deformações C-H e C-Cl as contribuições de carga não são dominantes. Para os estiramentos e deformações C-H as contribuições de carga são diminuídas pelas contribuições fluxo de carga e fluxo de dipolo, bem como por suas interações. Isto é também o caso para o acetileno, que possui um dos hidrogênios mais ácidos entre todos os hidrocarbonetos. O fenômeno de transferência de carga - contrapolarização foi utilizado para determinar com precisão a intensidade de 30 vibrações (estiramentos e deformações C-H) para átomos de carbono hibridizados sp3 e sp2. A carga de equilíbrio deve ser levada em consideração para descrever intensidades envolvendo hidrogênios ligados aos carbonos hibridizados sp, ainda que efeitos de transferência de carga ¿ contrapolarização ainda sejam importantes. Para os complexos de ligação de hidrogênio, a diminuição do fluxo de carga causa um aumento na intensidade de absorção devido às interações entre termos cruzados. Para os estiramentos simétrico e antissimétrico para a água o fluxo de dipolo é determinante para o aumento de intensidade, porque os termos de carga e fluxo de carga se cancelam quase inteiramente com sua interação. Os estudos QTAIM sugerem que para as intensidades dos trímeros, dímeros e monômeros de água e HF existem funções muito complexas de parâmetros eletrônicos, mas que essas funções podem ser representadas de maneira simplificada por contribuições CCFDF do hidrogênio "ponte", responsável por maior parte das flutuações eletrônicas / Abstract: Atomic charges are dominant to the C-F stretches and bendings to total intensity, even though the interactions with charge fluxes and dipole fluxes are also important. The sum of the charge contributions with these interactions enable a very precise estimate to the intensities . For C-H and C-Cl stretches and bending charge contributions are not dominant. For the C-H stretches and bendings charge contributions are reduced by the charge flux and dipole flux interactions. This is also the case for acetylene, which has one of the most acidic hydrogens among all hydrocarbons. The charge transfer ¿ counter polarization model was used to accurately determine the intensity of 30 C-H vibrations for both sp3 and sp2 carbon atoms. The the charge contributions must be taken into account to describe intensities involving hydrogens attached to sp hybridized carbons, even though charge transfer ¿ counter polarization effects are still important. For hydrogen bonding complexes, the decrease in charge flux causes an increase in absorption intensity due to the cross interactions terms. For the symmetric and antisymmetric stretches of the water dimer the dipole flux is crucial to the intensity increase, since the terms of charge and charge flux cancel each other almost entirely .The infrared intensities for complexes can be represented in a simplified manner by the CCFDF contributions of the "bridge" hydrogen , responsible for most electronic fluctuations. / Doutorado / Físico-Química / Doutor em Ciências
36

Análise de fluxo de carga eletrônica em modos vibracionais / Analysis of electronic charge flux in vibrational modes

Teodoro, Tiago Quevedo 19 February 2013 (has links)
Diversas metodologias foram desenvolvidas nas últimas décadas para cálculo de propriedades que representassem quantitativamente a distribuição de carga eletrônica de forma mais simplista. A mais básica destas propriedades é chamada de carga atômica. Contudo, não havendo unanimidade quanto à utilização de um formalismo de cálculo de carga para situações abrangentes de estudo, há a necessidade de trabalhos voltados para uma análise comparativa entre as respostas destes formalismos em termos de carga atômica e parâmetros derivados. Assim, fez-se nesta dissertação uma investigação sobre valores de carga atômica e propriedades dinâmicas relacionadas, com importância em estudos sobre movimentos vibracionais em moléculas, como fluxo de carga e fluxo de dipolo, obtidos com os formalismos de cálculo de carga de Mulliken, NPA, CHELPG e QTAIM. Neste trabalho também se avaliou o efeito da escolha do método de cálculo, como Hartree-Fock e métodos que incluem correlação eletrônica (MP2, MP4(SDQ) e CCSD), e do conjunto de funções de base, através de funções como cc-pVDZ, cc-pVTZ e cc-pVQZ, sobre estas propriedades dinâmicas. Os sistemas analisados incluíram moléculas diatômicas e triatômicas lineares (HF, HCl, LiH, NaH, NaCl, LiF, NaF, LiCl, BF, AlF, BeO, MgO, CO, ClF, CO2, CS2, OCS, HCN e HNC) formadas por ligações de caráter variado, desde altamente iônicas até covalentes e incluindo ligações múltiplas. Também foram estudadas moléculas de clorofluorometanos (CH4, CH3Cl, CH3F, CH2Cl2, CH2F2, CH2ClF, CHCl3, CHF3, CHCl2F, CHClF2, CCl2F2, CClF3, CFCl3, CCl4, e CF4) para observação do efeito da troca de substituintes nas propriedades citadas. Pelos resultados obtidos, pode-se afirmar que apenas os formalismos NPA e QTAIM apresentam bom comportamento quanto à convergência em relação ao método de cálculo e/ou tamanho do conjunto de funções de base utilizados no estudo do fluxo de carga. Entretanto, apenas os valores QTAIM são consistentes com certas considerações químicas fundamentais, como fluxos de carga tendendo a zero durante o estiramento de ligações de predominante caráter iônico, em moléculas com estruturas próximas à geometria de equilíbrio. As cargas e seus fluxos obtidos com Mulliken apresentaram alta dependência e problemas de convergência com a escolha da função de base, além de valores incoerentes em alguns sistemas. Por sua vez, CHELPG não se mostrou adequado à aplicação da aproximação finita de dois pontos na obtenção dos valores numéricos de fluxos de carga. A análise da resposta destas propriedades à troca de substituintes em moléculas de clorofluorometanos seguiu destacando positivamente QTAIM em relação aos outros formalismos. Enquanto CHELPG demonstrou oscilações inconsistentes em gráficos destes valores em função do número de átomos de cloro e/ou flúor, NPA e Mulliken se mostraram sensíveis à troca de substituintes, entretanto, os valores de fluxo de carga observados em alguns casos estão em desacordo com a tendência esperada na troca de átomos de hidrogênio por átomos de cloro ou flúor. / Several methodologies were developed in the last few decades in order to obtain a property which could represent quantitatively electronic charge distributions in a simple way. The fundamental quantity in this treatment is called atomic charge. However, as long as there is not an agreement about the most indicated method to determine atomic charges for general systems or responses under study, it is necessary to analyze, comparatively, how these methods behave in given situations and how the values derived from them respond in each case. Hence, an investigation including charges and related quantities as charge flux and atomic dipole flux, which are of interest to vibrational analysis, was done by means of values resulting from four formalisms, that are, Mulliken, NPA, CHELPG and QTAIM. In this study were also evaluated the changes in such dynamic properties when the calculations are done by means of different methods, as Hartree-Fock and methods that include electron correlation (MP2, MP4(SDQ) and CCSD) and, with different basis sets as cc-pVDZ, cc-pVTZ and cc-pVQZ. The systems analyzed were diatomic and linear triatomic molecules (HF, HCl, LiH, NaH, NaCl, LiF, NaF, LiCl, BF, AlF, BeO, MgO, CO, FCl, CO2, CS2, OCS, HCN and HNC) including diverse bonding character, such as highly ionic or covalent bonds along with multiple bonds. Also, charge and charge flux parameters in chlorofluoromethane molecules (CH4, CH3Cl, CH3F, CH2Cl2, CH2F2, CH2ClF, CHCl3, CHF3, CHCl2F, CHClF2, CCl2F2, CClF3, CFCl3, CCl4 and CF4) were studied to analyze the effects in these properties during the exchange of substituent atoms. Considering the data obtained, one can infer that only NPA and QTAIM formalisms result in satisfactory convergence patterns with chosen methods and/or basis set sizes during the determination of charge and charge flux values. However, only QTAIM charge fluxes seem to follow certain chemical considerations, as low values for charge flux in a bond enlargement in systems with a predominant ionic character close to their equilibrium geometry. The Mulliken formalism shows high dependence and convergence issues in basis set size increments, as well as some inconsistent values. On other hand, CHELPG formalism is not suited to the finite approach for numerical derivatives in its two-point version. The study of substituent effects in chlorofluoromethanes reinforces the performance of QTAIM when compared to other formalisms. While CHELPG returned inconsistent oscillations in plots against the number of chlorine/fluorine atoms, NPA and Mulliken exhibited some sensibility with the change of substituent, though the flux values observed in a few cases are in disagreement with the tendencies expected when the hydrogen atoms are switched by chlorine or fluorine atoms.
37

T?cnicas de simplifica??o de redes e otimiza??o multiobjetivo para an?lise de varia??es de tens?o em regime permanente provocadas por parques e?licos integrados ao sistema el?trico

Oiveira, Clovis Bosco Mendon?a 12 March 2010 (has links)
Made available in DSpace on 2014-12-17T14:54:54Z (GMT). No. of bitstreams: 1 ClovisBMO_TESE_1_a_75.pdf: 2549651 bytes, checksum: d03d835bba88763c08a8cb99eac15cd8 (MD5) Previous issue date: 2010-03-12 / Universidade Federal do Rio Grande do Norte / This study presents a description of the development model of a representation of simplified grid applied in hybrid load flow for calculation of the voltage variations in a steady-state caused by the wind farm on power system. Also, it proposes an optimal load-flow able to control power factor on connection bar and to minimize the loss. The analysis process on system, led by the wind producer, it has as base given technician supplied by the grid. So, the propose model to the simplification of the grid that allows the necessity of some knowledge only about the data referring the internal network, that is, the part of the network that interests in the analysis. In this way, it is intended to supply forms for the auxiliary in the systematization of the relations between the sector agents. The model for simplified network proposed identifies the internal network, external network and the buses of boulders from a study of vulnerability of the network, attributing them floating liquid powers attributing slack models. It was opted to apply the presented model in Newton-Raphson and a hybrid load flow, composed by The Gauss-Seidel method Zbarra and Summation Power. Finally, presents the results obtained to a developed computational environment of SCILAB and FORTRAN, with their respective analysis and conclusion, comparing them with the ANAREDE / Este trabalho apresenta uma descri??o do desenvolvimento de modelo para representa??o de rede simplificada aplicado em fluxo de carga h?brido para c?lculo das varia??es de tens?o em regime permanente provocadas pela conex?o de aerogeradores na rede el?trica. Al?m disso, se apresenta um fluxo de carga ?timo capaz de controlar remotamente o fator de pot?ncia na barra de conex?o e minimizar perdas. O princ?pio do processo de an?lise do sistema, conduzido pelo acessante, tem como base dados t?cnicos fornecidos pela rede acessada. Assim, se prop?e um modelo para simplifica??o de redes que permita a necessidade do conhecimento apenas dos dados referente a rede interna, ou seja, a parcela da rede de interesse para an?lise. Dessa forma, pretende-se fornecer meios para auxiliar na sistematiza??o das rela??es entre concession?ria e acessante. O modelo para simplifica??o de rede proposto identifica a rede interna, rede externa e as barras de fronteira a partir de dados provenientes de um estudo de vulnerabilidade da rede, atribuindo-as pot?ncias l?quidas flutuantes, ou seja, modelando-as como barras slack. Aplica-se o referido modelo no fluxo de carga Newton-Raphson e em um fluxo de carga h?brido, composto pelos m?todos de Gauss Seidel Zbarra e Soma de Pot?ncias. Ao final, apresentam-se os resultados obtidos por um ambiente computacional desenvolvido do SCILAB e FORTRAN, com suas respectivas an?lises e conclus?es, comparando-os com o ANAREDE
38

Uma nova abordagem para resolução de problemas de fluxo de carga com variáveis discretas / A new approach for solving load flow problems with discrete variables

Scheila Valechenski Biehl 07 May 2012 (has links)
Este trabalho apresenta uma nova abordagem para a modelagem e resolução de problemas de fluxo de carga em sistemas elétricos de potência. O modelo proposto é formado simultaneamente pelo conjunto de equações não lineares que representam as restrições de carga do problema e por restrições de complementaridade associadas com as restrições de operação da rede, as quais propiciam o controle implícito das tensões nas barras com controle de geração. Também é proposta uma técnica para a obtenção dos valores discretos dos taps de tranformadores, de maneira que o ajuste dessas variáveis possa ser realizado em passos discretos. A metodologia desenvolvida consiste em tratar o sistema misto de equações e inequações não lineares como um problema de factibilidade não linear e transformá-lo em um problema de mínimos quadrados não lineares, o qual é resolvido por uma sequência de subproblemas linearizados dentro de uma região de confiança. Para a obtenção de soluções aproximadas desse subproblema foi adotado o método do gradiente conjugado de Steihaug, combinando estratégias de região de confiança e filtros multidimensionais para analisar a qualidade das soluções fornecidas. Foram realizados testes numéricos com os sistemas de 14, 30, 57, 118 e 300 barras do IEEE, e com um sistema brasileiro equivalente CESP 53 barras, os quais indicaram boa flexibilidade e robustez do método proposto. / This work presents a new approach to the load flow problem in electrical power systems and develops a methodology for its resolution. The proposed model is simultaneously composed by nonlinear equations and inequations which represent the load and operational restrictions of the system, where a set of complementarity constraints model the relationship between voltage and reactive power generation in controled buses. It is also proposed a new technique to obtaining a discrete solution for the transformer taps, allowing their discrete adjustment. The method developed treats the mixed system of equations and inequations of the load flow problem as a nonlinear feasibility problem and converts it in a nonlinear least squares problem, which is solved by minimizing a sequence of linearized subproblems, whitin a trust region. To obtain approximate solutions at every iteration, we use the Steihaug conjugate gradient method, combining trust region and multidimensional filters techniques to analyse the quality of the provided solution. Numerical results using 14, 30, 57, 118 and 300-bus IEEE power systems, and a real brazilian equivalent system CESP 53-bus, indicate the flexibility and robustness of the proposed method.
39

Estratégias de paralelismo com GPGPU para otimização do processamento do cálculo do fluxo de carga em sistemas elétricos de potência

ARAÚJO, Igor Meireles de 23 March 2017 (has links)
Submitted by Hellen Luz (hellencrisluz@gmail.com) on 2017-07-04T18:45:28Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_EstrategiasParalelismoGpgpu.pdf: 1964519 bytes, checksum: 90e88c79511a80729d175e52be5bc30b (MD5) / Approved for entry into archive by Irvana Coutinho (irvana@ufpa.br) on 2017-08-18T13:25:09Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_EstrategiasParalelismoGpgpu.pdf: 1964519 bytes, checksum: 90e88c79511a80729d175e52be5bc30b (MD5) / Made available in DSpace on 2017-08-18T13:25:09Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_EstrategiasParalelismoGpgpu.pdf: 1964519 bytes, checksum: 90e88c79511a80729d175e52be5bc30b (MD5) Previous issue date: 2017-03-23 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O cálculo do fluxo de carga provê informações fundamentais em um sistema elétrico de potência, informações necessárias para que sejam realizados estudos nos sistemas. No entanto, o fluxo de carga só pode ser realizado em estado de regime permanente. Caso o sistema sofra alguma alteração, seja por variação nas cargas ou modificações dos equipamentos de controle, este cálculo é necessário ser refeito. Por essa necessidade, de constantemente ter que realizar o controle no fluxo de carga, começou-se uma busca por otimizar o tempo necessário desta tarefa. Uma das soluções abordadas para isso foi a utilização de computação paralela, a qual começou a ser utilizada a General Purpose Graphics Processing Unit (GPGPU) como uma alternativa de melhor custo benefício para execuções em arquiteturas paralelas, que consiste na utilização de Graphic Processing Units (GPU) não somente para processamento gráfico, mas também para propósitos gerais. Diversos trabalhos têm tirado proveito da utilização de GPGPU nos cálculos do fluxo de carga, contudo, não há um consenso sobre qual estratégia utilizar para paralelizar neste tipo de hardware, ficando a cargo de cada autor o trabalho de desenvolver seu próprio método, dificultando a utilização da arquitetura para a implementação desses cálculos, tanto para fins acadêmicos, quanto para o mercado. Pela falta de um consenso e palas divergências encontradas nos trabalhos, esta dissertação visa analisar as etapas do fluxo de carga, identificando quais estão mais aptas a paralelização em GPGPU com o intuito de realizar múltiplos cálculos do fluxo de carga simultâneos e reduzir o tempo necessário para o processamento, difundindo uma estratégia eficiente para sistemas de larga escala no mercado e no meio acadêmico, facilitando a replicação para trabalhos futuros com utilização de metaheurísticas para otimização de sistemas elétricos de potência. / The load flow calculation provides fundamental information for an electric power system. However, the load flow can only be carried out in the steady state, in the event of a system suffering any change, by variation in the loads or modifications of the control equipment, this calculation is necessary to be redone. Because of this need, frequently have to perform the load flow, a research has begun to optimize the time needed for this task. A General-Purpose Graphic Processing Unit (GPGPU) as a cost-effective alternative to parallel architecture runs, which has a GPU not only for graphics purposes but also for general purposes. Several works were taken for the use of GPGPU in load flow calculations, there is no consensus on the content of the material, being in charge of each one of the work of its own method, making it difficult to use the architecture for an implementation of calculations, both for academic purposes and for the market. Due to the lack of consensus and differences found in the work, this dissertation aims to analyze the steps of the load flow, identifying which is more suitable to parallelize in GPGPU in order to perform simultaneous load flow calculations and reduces the time required for the processing, an efficient strategy for large scale systems in the market and not academic environment, facilitate the replication for future works using metaheuristics for optimization of power electrical systems.
40

Uma nova abordagem para resolução de problemas de fluxo de carga com variáveis discretas / A new approach for solving load flow problems with discrete variables

Biehl, Scheila Valechenski 07 May 2012 (has links)
Este trabalho apresenta uma nova abordagem para a modelagem e resolução de problemas de fluxo de carga em sistemas elétricos de potência. O modelo proposto é formado simultaneamente pelo conjunto de equações não lineares que representam as restrições de carga do problema e por restrições de complementaridade associadas com as restrições de operação da rede, as quais propiciam o controle implícito das tensões nas barras com controle de geração. Também é proposta uma técnica para a obtenção dos valores discretos dos taps de tranformadores, de maneira que o ajuste dessas variáveis possa ser realizado em passos discretos. A metodologia desenvolvida consiste em tratar o sistema misto de equações e inequações não lineares como um problema de factibilidade não linear e transformá-lo em um problema de mínimos quadrados não lineares, o qual é resolvido por uma sequência de subproblemas linearizados dentro de uma região de confiança. Para a obtenção de soluções aproximadas desse subproblema foi adotado o método do gradiente conjugado de Steihaug, combinando estratégias de região de confiança e filtros multidimensionais para analisar a qualidade das soluções fornecidas. Foram realizados testes numéricos com os sistemas de 14, 30, 57, 118 e 300 barras do IEEE, e com um sistema brasileiro equivalente CESP 53 barras, os quais indicaram boa flexibilidade e robustez do método proposto. / This work presents a new approach to the load flow problem in electrical power systems and develops a methodology for its resolution. The proposed model is simultaneously composed by nonlinear equations and inequations which represent the load and operational restrictions of the system, where a set of complementarity constraints model the relationship between voltage and reactive power generation in controled buses. It is also proposed a new technique to obtaining a discrete solution for the transformer taps, allowing their discrete adjustment. The method developed treats the mixed system of equations and inequations of the load flow problem as a nonlinear feasibility problem and converts it in a nonlinear least squares problem, which is solved by minimizing a sequence of linearized subproblems, whitin a trust region. To obtain approximate solutions at every iteration, we use the Steihaug conjugate gradient method, combining trust region and multidimensional filters techniques to analyse the quality of the provided solution. Numerical results using 14, 30, 57, 118 and 300-bus IEEE power systems, and a real brazilian equivalent system CESP 53-bus, indicate the flexibility and robustness of the proposed method.

Page generated in 0.0637 seconds