• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 164
  • 48
  • 16
  • Tagged with
  • 225
  • 225
  • 201
  • 107
  • 95
  • 60
  • 44
  • 40
  • 32
  • 31
  • 31
  • 28
  • 19
  • 18
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Détermination des propriétés viscoélastiques de films multicouches de polyélectrolytes par sonde colloïdale au microscope de force atomique

Francius, Grégory Hemmerlé, Joseph. January 2007 (has links) (PDF)
Thèse doctorat : Chimie Physique : Strasbourg 1 : 2006. / Thèse soutenue sur un ensemble de travaux. Titre provenant de l'écran-titre. Bibliogr. 24 p.
32

Etude des mécanismes de renforcement et de dégradation des céramiques biomédicales à base de zircone

Deville, Sylvain Chevalier, Jérôme. January 2005 (has links)
Thèse doctorat : Génie des Matériaux : Villeurbanne, INSA : 2004. / Titre provenant de l'écran-titre. Bibliogr. p. 203-215. Publications de l'auteur p. 217-218. Index.
33

Manipulation dans le micro/nanomonde : dispositif haptique préhensile

Nigues, Antoine 06 September 2012 (has links) (PDF)
Le rayonnement synchrotron et la microscopie à sondes locales (SPM) sont deux des techniques les plus utilisées pour étudier les propriétés physiques et chimiques de nanostructures. Le couplage de ces deux techniques est prometteur pour les nanosciences en leur ouvrant de nouveaux horizons. D'un point de vue expérimental ce couplage est un défi exaltant et a déjà prouvé ses capacités par la combinaison de la Microscopie à Force Atomique (AFM) et de la diffraction de Rayons-X pendant le projet X-tip, qui, grâce au développement d'un microcope à force atomique embarqué sur une lugne de lumière synchrotron a permis l'étude du module de Young de microplots de germanium en procédant simulatanément à son indentation et à son analyse par diffraction. Cependant, cette configuration ne permet pas de manipuler en trois dimensions (3D). Le but ultime, pour notre nano-manipulateur est de manipuler en 3D avec un contrôle permanent des nano-forces exercées sur l'objet sous un faisceau d'analyse (rayon X, LASER). Le premier chapitre s'attarde donc sur les senseurs qui devront rendre compte des interactions à l'échelle nanométrique et permettre la saisie d'un objet individuel. Après un tour d'horizon de différentes techniques de micro/nanomanipulation disponibles à ce jour (micro-préhenseurs mécaniques basés sur la technologie MEMS, pinces optiques, préhenseurs basés sur la microscopie à force atomique conventionnelle) et devant les contraintes qu'implique le couplage d'un tel système avec les expériences synchrotron, le choix des oscillateurs à quartz (Diapason et LER) en tant que senseurs est expliqué. La microscopie à force atomique en générale et le fonctionnement particulier de ces oscillateurs sont décrits. Dans le second chapitre le développement instrumental de notre station de nanomanipulation est détaillé et notamment : Comment mettre en place ce type de résonateurs et la pointe associée pour réaliser à la fois l'imagerie AFM de l'échantillon et la préhension de l'objet? Comment contrôler le positionnement grossier et fin des trois éléments d'une nanomanipulation? Enfin le système haptique ERGOS et son couplage avec notre montage est décrit. Dans le dernier chapitre, deux types d'expériences sont présentés : le premier ne fait intervenir que notre montage piloté classiquement par ordinateur et montre ses capacités à réaliser la préhension d'objets micrométriques de manière contrôlée. Le second fait intervenir le couplage entre notre montage et le système haptique pour réaliser l'exploration rapide d'un échantillon ainsi que la localisation et la reconnaissance de forme d'objet sub-micronique. Ces expériences rendent compte des capacités de ce couplage à transmettre directement à un utilisateur les interactions à l'échelle nanométrique ainsi que la possibilité par l'intermédiaire de cette interface de réaliser des tâches complexes : manipulation sur une surface, reconnaissance de forme, et suivi de contour.
34

Préparation de films minces nano-structurés à partir de poly(acrylate de tert-butyle)-bloc-poly(méthacrylate de méthyle) /

Grenon, Marie-Claire. January 2007 (has links) (PDF)
Thèse (M.Sc.)--Université Laval, 2007. / Bibliogr.: f. [85]-86. Publié aussi en version électronique dans la Collection Mémoires et thèses électroniques.
35

Pointes AFM à nanotube de carbone pour la métrologie in-line de procédés de fonctionnalisations de surface / AFM probe with Carbon Nanotube for in line metrology of surface functionalization processes

Robin, Ludovic 09 December 2016 (has links)
Actuellement, les recherches sur la fonctionnalisation des surfaces sont en pleine effervescence. Dans ce manuscrit, nous proposons une approche innovante pour mesurer l’efficacité de cette fonctionnalisation. Cette approche est basée sur l’utilisation d’un microscope à force atomique, opérant dans un mode dit de « modulation de fréquence ». Cet outil couplé aux pointes greffées d’un nanotube de carbone, que nous appellerons « sonde », permet d’obtenir des mesures qu’il serait impossible d’effectuer avec des pointes standards. En métrologie, afin d’assurer une bonne reproductibilité des mesures, nous avons besoin d’avoir des sondes ayant des caractéristiques les plus similaires possibles. Ceci a nécessité la mise en oeuvre d’une méthode pour optimiser la fabrication des sondes, ainsi qu’une définition de critères pour les classer dans différents grades de qualités. L’incertitude de répétabilité et de reproductibilité des mesures effectuées avec des sondes de grade « A » a été quantifiée. Ces mesures ont démontré que ces sondes sont compatibles en termes de robustesse et de sensibilité pour la caractérisation de surfaces fonctionnalisées, dont l’épaisseur est supérieure à la monocouche. Des mesures de cartographie effectuées sur de deux types de surfaces fonctionnalisées ont permis de dissocier la mesure de topographie de la réponse mécanique du nanotube en interaction avec la surface. / At present, the researches on the surface functionalization are in full effervescence. In this manuscript, we propose an innovative approach to measure the efficiency of this functionalization. This approach is based on the use of an atomic force microscope, operating in a mode called "frequency modulation". This tool coupled with the grafted tips with a carbon nanotube, which we will call "probe", allows to obtain measurements which would be impossible to make with standard tips. However, in metrology, in order to ensure good reproducibility of the measurements, we need to have probes with characteristics that are as similar as possible. This required the implementation of a method to optimize the manufacture of the probes, as well as a definition of criteria to classify them in different grades of qualities. The uncertainty of repeatability and reproducibility of the measures made with probes of rank "A" were quantified. These measurements have demonstrated that these probes are compatible in terms of robustness and sensitivity for the characterization of functionalized surfaces, whose thickness is superior to the monolayer. Mapping measurements carried out on two types of functionalized surfaces enable to dissociate the topography measurement from the mechanical response of the nanotube in interaction with the surface.
36

Etude de l'intéraction nanoparticules-bactéries : application à l'élaboration d'un biocapteur / Study of the interactions between nanoparticles and bacteria : application in the design of a biosensor for bacteria detection

Mathelié-Guinlet, Marion 17 October 2017 (has links)
Malgré l'enthousiasme croissant pour les nanotechnologies, les nanoparticules (NPs) peuvent interagir avec les systèmes biologiques et affecter leur comportement, et pourraient ainsi présenter un danger pour les écosystèmes et l’Homme. Il est donc essentiel de connaître leurs mécanismes d'interactions afin non seulement de prévenir leurs risques potentiels, mais également de bénéficier de leurs propriétés uniques, par exemple dans la conception des biocapteurs. Dans ce contexte, nous étudions la cytotoxicité des NPs de silice, de tailles et charges diverses, sur les propriétés des bactéries Escherichia coli et Bacillus subtilis, au moyen de la microscopie à force atomique et des tests de viabilité. Les NPs chargées négativement (NPs-) de diamètre inférieur à un diamètre critique φc, 50 - 80 nm, (i) mènent à l'isolation des bactéries E. coli, (ii) induisent une "sphérification" de la cellule initialement en bâtonnet, (iii) provoquent des lésions dans la membrane externe et une réorganisation de sa structure. Pour la bactérie B. subtilis, seule la dégradation de la structure du peptidoglycane a été observée. Cependant, pour les deux souches, une activité antibactérienne a été démontrée pour les NPs- en dessous de φc, qui peuvent conduire à la lyse cellulaire tandis que, au-dessus de φc, les NPs- n’ont aucun effet sur la population, la morphologie ou la structure bactérienne. En ce qui concerne les NPs chargées positivement, elles conduisent, quel que soit leur diamètre, à une forte agrégation des cellules, en raison des interactions électrostatiques, et tendent à favoriser la formation d'invaginations membranaires, ne menant pas nécessairement à la lyse cellulaire. Cette étude fondamentale a mené au développement d’un biocapteur électrochimique pour la détection de bactéries, application notable pour des problèmes biomédicaux, environnementaux et de défense. Les NPs, intégrées à ces outils, offrent un mode de détection rapide, très sensible et peu coûteux. Expérimentalement, une multicouche de polyélectrolytes a été utilisée pour immobiliser des NPs inoffensives (φ = 100 nm), auxquelles sont ensuite fixés des anticorps spécifiques, afin d'améliorer la détection finale de la bactérie E. coli. L’ensemble des étapes a été optimisé par le procédé du spin coating et étudié à l'aide de mesures de microbalance à quartz et de voltametrie cyclique. L’intégration de NPs au biocapteur a permis une détection linéaire et non saturée des bactéries E. coli dans une large gamme de concentration (jusqu’à 10^9 CFU/mL) pour une limite de détection de 10^6 CFU/mL. / Despite the growing enthusiasm for nanotechnologies, nanoparticles (NPs) might put environmental safety and human health at risk, as they can interact with biological systems and affect their behavior. It is therefore essential to know their mechanisms of interactions in order not only to prevent their potential risks but also to benefit from their unique properties, such as in biosensors design. In this context, we study the cytotoxicity of silica NPs, with diverse sizes and charges, on the properties of Escherichia coli and Bacillus subtilis bacteria, by means of atomic force microscopy and viability tests. Negatively charged NPs (NPs-) with a diameter φ lower than a critical diameter φc, 50 - 80 nm, (i) lead to the isolation of E. coli bacteria, (ii) induce a "spherification" of the cell initially rod shaped, and (iii) cause the formation of pore-like lesions in the outer membrane and a reorganization of its structure. For B. subtilis bacteria, only the degradation of the peptidoglycane’s structure was observed. Though, for both strains, an antibacterial activity was shown for NPs- below φc, which potentially lead to the cell lysis whereas, above φc, NPs- have no effect on population, morphology or bacterial structure. As positively charged NPs are concerned, whatever their diameter, they lead to a strong aggregation of the cells, due to electrostatic interactions, and tend to favor the formation of membrane invaginations, not necessarily involving cell lysis. This fundamental study has been used to develop an electrochemical biosensor for bacteria, which are of great importance for biomedical, environmental and defense issues. NPs involved in such tools offer a fast, high-sensitive and low-cost way of detection. A polyelectrolyte multilayer was used to immobilize harmless NPs (φ = 100 nm), which are, then, functionalized with specific antibodies, in order to enhance the final detection of E. coli bacteria. All steps were optimized by a spin coating process and studied through quartz microbalance and cyclic voltametry measurements. Integrating NPs in this biosensor resulted in a linear and unsaturated detection of E. coli bacteria in a wide range of concentration (until 10^9 CFU/mL) and a limit of detection of 10^6 CFU/mL.
37

Modélisation multidimensionnelle des interactions électrostatiques pointe/diélectrique en microscopie à champ proche / Multidimensional modeling of electrostatic interactions between the tip and dialectric in near field microscopy

Boularas, Abderrahmane 13 May 2015 (has links)
Les techniques de microscopie en champ proche se sont fortement diversifiées au cours des dernières années et ne sont plus désormais cantonnées aux seuls laboratoires experts dans le domaine mais sont exploitées plus largement par les spécialistes des matériaux et des 'micro-' ou 'nano-'objets. Pour ce qui concerne les matériaux diélectriques, des techniques dérivées de la microscopie à force atomique -AFM-, telles que la microscopie à force électrostatique -EFM, ou à force de Kelvin -KFM, permettent d'obtenir de nouvelles informations, à l'échelle nanométrique, sur l'état de charge des isolants et sur leur capacité à stocker/dissiper les charges. Cependant, ces techniques ne permettent pas de connaître précisément la répartition spatiale de la charge en latéral et en profondeur dans les matériaux isolants, données indispensables pour une meilleure compréhension des phénomènes de transport et de piégeage de charges. C'est pourquoi, nous nous sommes intéressés aux courbes de forces électrostatiques comme nouvel outil susceptible de permettre la localisation de la charge. L'objectif de la thèse est donc de comprendre le lien entre l'allure de la courbe de force et le positionnement spatial de la charge dans le matériau. Pour ce faire, deux études sont menées en parallèle : une étude expérimentale et une étude par modélisation numérique. Les travaux de recherche sont focalisés principalement sur la partie simulation de la sonde AFM par une modélisation électrostatique des phénomènes physiques en jeu. Un des verrous à lever dans ces travaux est la disparité d'échelle des objets modélisés et le caractère tridimensionnel du système. Dans cet objectif, un modèle mathématique pour l'étude des interactions électrostatiques entre une pointe AFM et la surface d'un matériau diélectrique a été développé en 2D. La discrétisation des équations décrivant le système est basé sur un nouveau schéma numérique du type volumes finis d'ordre élevé obtenu par le principe de la reconstruction polynômiale. Ce premier modèle a permis de comprendre l'influence de la géométrie de la pointe, notamment le rayon de courbure de l'apex et l'angle de demi-ouverture, sur l'aspect qualitatif et quantitatif des courbes de force. Les résultats montrent, par exemple, que plus le rayon de courbure de la pointe est faible plus la courbure de la courbe de force est prononcée. Ces résultats sont conformes à l'expérience. Pour parfaire notre étude sur la géométrie de la pointe, un premier modèle en 3D a été développé à l'aide du logiciel commercial Comsol Multiphysics(r). Plusieurs formes de pointe ont été testées : conique, tétraèdre et pyramidale. Les courbes de forces obtenues par simulation ont été comparées aux données expérimentales permettant ainsi de trouver une forme optimale représentative de la pointe réelle. Un deuxième modèle en 3D basé sur les équations électromécaniques a été développé pour prendre en compte l'effet du bras de levier sur les courbes de force. Les résultats obtenus montrent que le bras de levier ne modifie pas la forme de la courbe de force obtenue par la pointe seule mais rajoute simplement une composante continue sur celle-ci. / The Scanning Probe Microscopy techniques (SPM) are highly diversified and no longer confined to expert laboratories, being widely used by material scientists for "micro" or "nano" applications. The use of Atomic Force Microscopy (AFM), and techniques derived from it, such as Electrostatic Force Microscopy (EFM) or Kelvin Force Microscopy (KFM), provides a considerable advantage allowing the acquisition of new information down to nanoscale, such as the charge state of dielectric materials and their ability to store and dissipate charges. However, these techniques do not allow to precisely know the spatial distribution of the lateral and deep distribution of the space charge in the insulating materials, required for a better understanding of the phenomena of transportation and charge trapping data. For this purpose, we are interested in the electrostatic force distance curve -EFDC- as a new tool to allow the location of the space charge. The aim of the thesis is to understand the relationship between the shape of the force curve and the spatial positioning of the space charge in the material. To do this, two studies were conducted in parallel: an experimental study and a study by numerical modeling. The research work here is focused mainly on the simulation of the AFM probe by electrostatic modeling of physical phenomena. One of the difficult obstacles to do in this work is the taken in account disparity of scale objects modeled and the three-dimensionality of the system. For this purpose, a mathematical model for the study of electrostatic interactions between an AFM tip and the surface of a dielectric material has been developed in 2D. The discretization of equations describing the system is based on a new numerical scheme of high order finite volume method obtained by the principle of polynomial reconstruction operator. This first model was used to understand the influence of the geometry of the tip, including the radius of curvature of the apex and the half-opening angle on the qualitative and quantitative aspects of the force curves. The results show, for example, more than the radius of curvature of the tip is smaller the curvature of the force curve is pronounced.
38

Optimisation de la mesure de travail de sortie par microscopie à sonde locale sous vide : application aux dispositifs avancés / Optimization of the work function measurement by local probe microscopy under vacuum : application to advanced devices

You, Lin 01 June 2012 (has links)
La compréhension des propriétés électriques de nano-objets est essentielle pour le développement s des nanotechnologies. La microscopie à force Kelvin (KFM) est une des techniques les plus utiles pour cartographier simultanément la topographie et la différence de potentiel de contact (CPD) à l'échelle nanométrique. Après 20 ans de développement, la KFM est principalement utilisé dans des conditions normales de pression et de température, permettant d'effectuer, de manière simple, de multiples analyses comparatives. Toutefois, sous ultra-vide (UHV), comme la surface est contrôlée et que la sensibilité est meilleure, des mesures plus précises et plus fiables sont réalisables. Dans la première partie, la mesure KFM sous atmosphère ambiante est améliorée en développant la technique simple-passage à la fois en modulation de fréquence (FM) et en modulation d'amplitude (AM). Une électronique externe Nanonis a été adaptée sur les AFMs commerciaux (Dimension 3100 et MultiMode, Bruker). Une étude comparative avec le mode Lift a été réalisée sur des couches de graphène épitaxié sur échantillon de SiC. L'effet de la distance pointe-échantillon sur le contraste et la résolution est décrit ainsi que l'influence des paramètres expérimentaux. Une amélioration significative du contraste et de la résolution est clairement observée sur les résultats obtenus par la technique simple passage en modulation de fréquence, indépendamment de la distance pointe-échantillon. Dans une deuxième partie, la technique KFM est développée sous vide secondaire. Le travail instrumental est réalisé sur un AFM EnviroScope de chez Bruker, qui a été équipé d'une électronique externe Nanonis, permettant de mesurer simultanément la topographie en mode non-contact et la CPD en modulation d'amplitude ou de fréquence. Les résultats montrent que la CPD mesurée est comparable à celle obtenue avec une mesure sous ultravide. Enfin, après avoir posé les bases à la fois expérimentale et théorique de la KFM, cette technique est utilisée pour caractériser les hétérostructures CdTe/CdS en films minces utilisés pour les applications de cellules solaires. Un protocole de préparation d'échantillon sur la tranche a été spécialement développé. L'hétérojonction CdTe/CdS est étudiée sous polarisation à la fois dans l'obscurité et sous éclairement. L'influence de l'épaisseur de la couche de CdS est également étudiée pour comprendre son effet dramatique sur le rendement des cellules solaires. / The development of nanoscience makes the understanding of the electrical properties of nano-objects essential. The Kelvin Force Microscopy (KFM) is one of the most useful techniques to map at the nanoscale and simultaneously both the topography and contact potential difference (CPD). After 20 years of development, KFM is mainly operated under air at normal pressure, allowing to perform, in an easy way, multiple comparative analyses. However, under UHV, as the surface is controlled and the sensitivity improved, more accurate and reliable measurements can be achieved. In the first part, KFM under ambient atmosphere is improved by developing the single-scan method using either a frequency modulation (FM) or an amplitude modulation (AM) mode. An external Nanonis electronic has been implemented on commercial AFMs (Dimension 3100 and MultiMode, Bruker). A comparative study with the common Lift-mode is done by imaging epitaxial graphene layers on SiC sample. The tip-sample separation effect on the CPD contrast and resolution is described as well as experimental settings. It is shown that higher contrasts are obtained using single-scan frequency modulation KFM regardless the tip-sample operating distance. In a second part, the KFM technique under secondary vacuum is developed. The instrumental work is carried out with an EnviroScope AFM from Bruker. We outfitted our Veeco's AFMs with an external Nanonis electronic to perform simultaneously the acquisition of topography and CPD using either the amplitude or the frequency modulation mode. The upgrade of the electronic has raised compatibility issues. Our results show that the comparable results are obtained with KFM under UHV. Finally, having laid down both the experimental and theoretical groundwork of the KFM, this technique is used to characterize CdTe/CdS heterostructures used in thin films solar cell application. A protocol for the cross section sample preparation has been specifically developed. The CdTe/CdS heterojunction is studied under polarization both in dark and under illumination. The influence of the CdS layer thickness is also studied to understand its dramatic effect on the solar cell efficiency.
39

Manipulation dans le micro/nanomonde : dispositif haptique préhensile / Micro/nanomanipulation : Micro/nanomanipulation : Haptic device

Nigues, Antoine 06 September 2012 (has links)
Le rayonnement synchrotron et la microscopie à sondes locales (SPM) sont deux des techniques les plus utilisées pour étudier les propriétés physiques et chimiques de nanostructures. Le couplage de ces deux techniques est prometteur pour les nanosciences en leur ouvrant de nouveaux horizons. D'un point de vue expérimental ce couplage est un défi exaltant et a déjà prouvé ses capacités par la combinaison de la Microscopie à Force Atomique (AFM) et de la diffraction de Rayons-X pendant le projet X-tip, qui, grâce au développement d'un microcope à force atomique embarqué sur une lugne de lumière synchrotron a permis l'étude du module de Young de microplots de germanium en procédant simulatanément à son indentation et à son analyse par diffraction. Cependant, cette configuration ne permet pas de manipuler en trois dimensions (3D). Le but ultime, pour notre nano-manipulateur est de manipuler en 3D avec un contrôle permanent des nano-forces exercées sur l'objet sous un faisceau d'analyse (rayon X, LASER). Le premier chapitre s'attarde donc sur les senseurs qui devront rendre compte des interactions à l'échelle nanométrique et permettre la saisie d'un objet individuel. Après un tour d'horizon de différentes techniques de micro/nanomanipulation disponibles à ce jour (micro-préhenseurs mécaniques basés sur la technologie MEMS, pinces optiques, préhenseurs basés sur la microscopie à force atomique conventionnelle) et devant les contraintes qu'implique le couplage d'un tel système avec les expériences synchrotron, le choix des oscillateurs à quartz (Diapason et LER) en tant que senseurs est expliqué. La microscopie à force atomique en générale et le fonctionnement particulier de ces oscillateurs sont décrits. Dans le second chapitre le développement instrumental de notre station de nanomanipulation est détaillé et notamment : Comment mettre en place ce type de résonateurs et la pointe associée pour réaliser à la fois l'imagerie AFM de l'échantillon et la préhension de l'objet? Comment contrôler le positionnement grossier et fin des trois éléments d'une nanomanipulation? Enfin le système haptique ERGOS et son couplage avec notre montage est décrit. Dans le dernier chapitre, deux types d'expériences sont présentés : le premier ne fait intervenir que notre montage piloté classiquement par ordinateur et montre ses capacités à réaliser la préhension d'objets micrométriques de manière contrôlée. Le second fait intervenir le couplage entre notre montage et le système haptique pour réaliser l'exploration rapide d'un échantillon ainsi que la localisation et la reconnaissance de forme d'objet sub-micronique. Ces expériences rendent compte des capacités de ce couplage à transmettre directement à un utilisateur les interactions à l'échelle nanométrique ainsi que la possibilité par l'intermédiaire de cette interface de réaliser des tâches complexes : manipulation sur une surface, reconnaissance de forme, et suivi de contour. / The synchrotron radiation and scanning probe microscopy (SPM) are the (two) most used techniques to study the physical and chimical properties of nanostructures. Coupling these two techniques is promising for the nanosciences by opening news horizons. From an experimental point of view, this coupling is an exciting challenge and has already proven its skills with the combination of Atomic Force Microscopy (AFM) and X-Ray diffraction during the X-tip project, which, thanks to the development of an atomic force microscope embended on a synchrotron beamline, has permitted to study Young's modulus of germanium microplots proceeding simultaneously with its indentation and its diffraction analysis. However, this configuration doesn't permit a three dimension (3D) manipulation. The ultimate goal, for our nano-manipulator, is to manipulate in 3D with a permanent control of nano-forces exerted on the object undcer a scanning beam (X-Ray, laser). The first chapter therefore focuses on the sensors which measure the interactions at a nanometer scale and permit the seizure of an individual object. After an overview of the differents techniques of micro/nano-manipulation available today ( mechanical micro-grippers based on MEMS technology, optic tweezers, grippers based on conventionnal atomic force microscopy), and in front of the constraints implied by the coupling of this kind of system with the synchrotron experiments, the choice of quartz oscillators (Tunning fork and LER) as sensors is explained. The atomic force microscopy in general and the particular behavior of these oscillators is described. In the second chapter, the instrumental development of our nano-manipulation station is detailed and especially : How to implement this type of resonators and the associated tip to achieve both AFM imaging of the sample and gripping of the object ? How to control the coarse and fine positionning of the three elements of a nano-manipulation ? Finally, the haptic system ERGOS et its coupling with our assembly is describe. In the last chapter, two types of experiments are presented : the first involves only our assembly piloted classically with a computer and show its skills in the achievement of gripping of micrometric objects in a controled way. The second involves the coupling between our assembly and the haptic system to achieve the fast exploration of a sample and also the location and shape recognition of sub-micronic objects. These experiments reflect the capacities of this coupling to directly transmit to an user the interactions at a nanometer scale and also the possibility using this interface to achieve complex tasks : manipulation on a surface, shape recognition and contour tracking.
40

Contribution à la mise en place d’un microscope à force Atomique métrologique (mAFM) : Conception d’une tête AFM métrologique et caractérisation métrologique de l’instrument. / Contribution to the development of metrological atomic force microscope (mAFM) : design of a metrological AFM head and metrological caracterization of the instrument

Boukellal, Younes 02 April 2015 (has links)
Les microscopes en champ proche sont très largement utilisés pour caractériser des propriétés physiques à l’échelle du nanomètre. Afin d’assurer la cohérence et l’exactitude des mesures dimensionnelles qu’ils retournent, ces microscopes ont besoin d’être étalonnés périodiquement. Le raccordement à la définition du mètre SI est assuré par le biais d’étalons de transfert dont les caractéristiques dimensionnelles sont étalonnées à l’aide d’un Microscope à Force Atomique métrologique (mAFM).Les travaux de thèse portent sur la contribution à la mise en place du Microscope à Force Atomique métrologique du LNE dans le but de caractériser et réduire l’incertitude de mesure. Une tête AFM passive thermiquement et spécifiquement conçue pour des applications de nanométrologie dimensionnelle a été développée et intégrée au mAFM. Elle comporte un système original pour mesurer les déflexions du levier nécessaire à la détection des forces s’exerçant à l’extrémité de la pointe. Il utilise une évolution de la méthode du levier optique qui permet de déporter les sources de chaleurs à l’extérieur de l’instrument. Pour cela, un nouveau capteur a été développé. Il est basé sur l’utilisation d’un bundle composé de 40 000 microfibres optiques structurées en quatre quadrants. Il remplace avantageusement une photodiode quatre quadrants et permet de transporter le signal lumineux jusqu’à des photodiodes placées à l’extérieur de l’instrument. Ce système a été modélisé, caractérisé et validé expérimentalement. La tête AFM ainsi développée est passive thermiquement. Sa conception repose sur la dissociation complète de la chaine métrologique, constituée en Zerodur, afin de lui conférer une excellente stabilité thermique et mécanique. Pour les mêmes raisons, le châssis de la tête qui supporte l’ensemble des composants et notamment le système de mesure des déflexions du levier est entièrement conçu en Invar. Cette tête repose sur une structure motorisée constituée de trois moteurs à reptation permettant l’approche de pointe mais également le réglage des interféromètres. Après intégration de la tête dans le mAFM, l’ensemble de l’instrument a été caractérisé afin d’établir son bilan d’incertitude. Plusieurs composantes ont ainsi été évaluées expérimentalement comme la non-linéarité et la stabilité de la mesure de position par interférométrie, les rotations parasites du scanner, les erreurs d’Abbe, les défauts de rugosité et de planéité des miroirs ainsi que les erreurs de bras mort. L’impact de chaque composante a été quantifié et listé dans le bilan d’incertitude. Ces travaux ont permis d’avoir une première estimation de l’incertitude de mesure du mAFM. / Scanning probe microscopes are very well used for characterization at the manometer scale. To ensure the measurement coherency and the accuracy of the results, those microscopes need to be periodically calibrated. It’s done thanks to reference standards whose dimensional characteristics are measured by a metrological atomic force microscope (mAFM) for example.The aim of this thesis work is the improvement of the metrological AFM of the LNE in order to reduce the measurement uncertainty. To reach this goal, a thermally passive AFM head has been developed and integrated on the instrument. It contains an original system to measure the cantilever deflexion and thus detect the force acting between the sample and the tip. This system is based on the optical beam deflection method but allow deporting the heat sources outside the instrument. To reach this goal, a new specific sensor has been developed. It is based on a four quadrant optic fibre bundle that contains 40 000 micro-fibre and which is ideal to replace the existing four quadrant photodiode and its conditioning electronic circuit with the bundle and its conditioning electronic circuit placed outside the instrument. This sensor has been modelled, and experimentally validated.The Developed AFM head which integrates the deflection measurement system is then thermally passive. Its design is based on the complete dissociation of the metrological loop and the structural loop. The metrological loop is made of Zerodur® in other to acquire an excellent mechanical and thermal stability and thus reduce the thermal dilatation. For the same reason, the AFM head support frame is fully made of Invar. The AFM head is placed on a motorized frame based on three piezo-leg motors (tripod) to make the tip/sample approach but also to set the interferometer signal quality. The interferometer signal is improved by combining the linear displacements of the three motors to generate small rotations. This allows setting the parallelism of the mirrors linked to the head with those linked to the translation stage.Once the AFM head integrated on the instrument, the assembly is characterized in order to establish the uncertainty budget. Different uncertainty components have been experimentally evaluated as for example: the interferometer non linearity, the drift of the XYZ position, the parasitic rotations of the translation stage, the Abbe error, the roughness and the flatness of the mirrors and the dead path errors. The impact of the each component has been quantified and listed in the uncertainty budget. This allowed getting a first estimation of the combined uncertainty of the instrument.

Page generated in 0.1433 seconds