• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 11
  • 9
  • 1
  • Tagged with
  • 22
  • 8
  • 7
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Recherche de gaz/mélange gazeux sans hexafluorure de soufre pour des applications haute tension

Nechmi, Houssem Eddine 12 December 2016 (has links)
Dans l’état actuel des techniques utilisées pour l’isolation gazeuse des systèmes d’énergie électrique à haute tension, l’hexafluorure de soufre (SF6) tient une place prépondérante en raison de ses performances diélectriques et chimiques (bonne tenue diélectrique, point d'ébullition bas, stabilité chimique, non toxicité, etc.) ; il est l’un des meilleurs isolants gazeux connus à ce jour. Il est principalement utilisé dans les appareils de coupure pour l’extinction de l’arc électrique, les lignes de transmission à isolation gazeuse et autres équipements de puissance. Cependant, de par sa taille excessive, sa durée de vie trop importante et son grand effet radiatif, la molécule de SF6 constitue un agent aggravant de l’effet de serre avec un potentiel de réchauffement global (PRG ou GWP en anglais) très élevé (23900 fois supérieur à celui du CO2). Ainsi, les recommandations internationales (COP3) et européennes (règlement (UE) n°517/2014) tendent à restreindre très fortement, voire interdire son utilisation pour préserver l’environnement. Depuis, une tâche importante a été engagée par les industriels pour trouver d’autres gaz ou mélanges de substitution avec moins d’impact sur l’environnement et des exigences diélectriques comparables ou supérieures à celles du SF6. Les candidats les plus prometteurs appartiennent tous au groupe des molécules poly-fluorées (CF3I, Perfluorinated Ketones, Octafluorotetra-hydrofuran, Hydrofluoroolefin (HFOs) ou heptafluoro-iso-butyronitrile(Fluoronitriles)), Ils offrent tous une tenue diélectrique entre 1.2 et 2.71 par rapport au SF6. Ces molécules candidates ouvrent des perspectives intéressantes pour la substitution de SF6 dans l’appareillage sous enveloppe métallique destiné pour le réseau T&D haute tension. Leur principal inconvénient réside dans leur masse moléculaire élevée, ce qui implique une température de fonctionnement plus élevée par rapport au SF6. Ce travail porte sur l’étude expérimentale des performances diélectriques des mélanges de Fluoronitriles-CO2. Les paramètres intrinsèques de l’avalanche électronique sont identifiés à partir des courants de la décharge stationnaire de Townsend. L’évaluation de ces courants a permis d’extraire le coefficient d’ionisation effectif pour différents mélanges de Fluoronitriles. Une comparaison du potentiel d’isolation de ces mélanges avec celui du SF6 pur, dans différentes géométries électrodes (sphère-plan, pointe-plan, sphère-sphère, système avec le profil de Bruce), sur une large gamme de pression et pour toutes les formes d'ondes de tension normalisées pour d'isolation est présentée. Les résultats de mesures de tensions de claquage de ces mélanges et du CO2 pur, pour comparaison, dans un système coaxial cylindrique de taille réelle, similaire à celui utilisé dans les postes à enveloppe métallique (GIS - Gas Insulated Switchgear), sont également présentés ; une étude de l’influence de la surface et de l’état de surface des électrodes sur la tenue diélectrique en fonction de différents paramètres (pression, rugosité, surface effective, forme de tension et polarité, température de gaz …) est faite. / SULPHUR hexafluoride, SF6, is the most common compressed gas used in high voltage power equipment since the 1950s and in HV transmissions and substations applications (GIS, GCB, GIL …), SF6 holds a prominent place because of its dielectric and chemical performance (high dielectric strength, non-toxicity, low condensation temperature, thermal stability, non-flammability, chemical inactivity with the other constituent materials of the apparatus, availability and moderate cost). It is one of the best insulators gas known today. Despite its excellent properties in both electrical insulation and current interruption performance, the excessive size, the radiative effect and atmospheric lifetime of SF6 molecule makes this gas an aggravating agent for the greenhouse gas effect, with a very high global warming potential (GWP) (23900 times higher than CO2). Thus, the international and European recommendations (COP 3) and (Regulation (EU) No 517/2014) respectively tend to strongly restrict or prohibit its use to preserve the environment. Since then, an important task was undertaken by manufacturers to find other gases or mixtures of substitution with less impact on the environment and dielectric performances comparable or superior to those of SF6. Naturally, the investigations were oriented towards halogenated products that have reduced GWP such as CF3I, Perfluorinated Ketones, Octafluorotetra-hydrofuran, Hydrofluoroolefin (HFOs) or heptafluoro-iso-butyronitrile (Fluoronitriles)), all offer a dielectric strength between 1.2 and 2.71 relative to SF6. These candidates open interesting perspectives for the substitution of SF6 in the GIS applications designed for high voltage T & D network. Their main disadvantage is their high molecular weight, which implies a higher operating temperature compared to SF6. This work deals with the experimental study of dielectric performance of Fluoronitriles CO2 mixtures. Intrinsic parameters of the measured steady state Townsend swarm currents are identified. The evaluation of the currents produce the effective ionization rate constant in different Fluoronitriles-CO2 mixtures. In addition, this work provides a conventional assessing of insulating performance with typical breakdown experiments, conducted for different field configurations over a wide pressure range and for all standard voltage waveforms. The experiments are conducted with different electrodes geometries namely plane-to-plane (Bruce profile), sphere-to-sphere, sphere-to-plane and rod-to-plane. AC and LI breakdown characteristics of CO2 and different Fluoronitriles /CO2 mixtures gas were experimentally analyzed in a real scale GIS coaxial test system. The main investigated parameters are the effect of roughness and effective surface area HV inner conductor on insulation performance, depending on various parameters (pressure, form and voltage polarity, gas temperature…).
22

Adaptation de maillage anisotrope par prescription de champ de métriques appliquée aux simulations instationnaires en géométrie mobile

Olivier, Géraldine 22 April 2011 (has links) (PDF)
Cette thèse s'intéresse aux simulations dépendantes du temps impliquant des géometries fixes ou mobiles. Ce type de simulations est l'objet d'attentes grandissantes de la part des industriels, qui souhaiteraient voir réaliser ce type de calculs de façon systématique au sein de leurs centres de recherche, ce qui n'est clairement pas le cas à l'heure actuelle. Ce travail tente de satisfaire en partie cette demande et vise notamment à améliorer la précision ainsi que l'efficacité en termes de temps de calcul des algorithmes actuellement utilisés dans ce contexte. Les méthodes d'adaptation de maillage anisotrope par prescription d'un champ de métriques, qui ont aujourd'hui atteint une certaine maturité, notamment dans leur application aux simulations stationnaires, constituent une piste très prometteuse pour l'amélioration des calculs évoluant en temps, mais leur extension dans ce contexte est loin d'être triviale. Quant à leur utilisation sur les simulations en géométries mobiles, seules quelques tentatives peuvent être répertoriées, et très peu portent sur des problèmes réalistes en trois dimensions. Cette étude présente plusieurs nouveautés sur ces questions, notamment l'extension de l'adaptation de maillage multi-échelles par champ de métriques aux problèmes instationnaires en géométries fixes et mobiles. Par ailleurs, essentiellement dans une optique de réduction des temps de calculs, une stratégie originale à été adoptée pour réaliser des calculs impliquant des maillages mobiles. Notamment, il est démontré par la pratique dans cette thèse qu'il possible de déplacer des objets en trois dimensions sur de grandes distances en maintenant le nombre de sommets du maillage constant, c'est-à-dire en limitant les types d'opérations de modification de maillage autorisés. Il en résulte un gain conséquent en terme de temps de calcul aussi bien au niveau du déplacement de maillage qu'au niveau de la résolution numérique. Par ailleurs, un nouveau schéma est proposé qui permet de gérer les changements de connectivité du maillage de manière cohérente avec la description Arbitrary-Lagrangian-Eulerian des équations physiques. La plupart de ces nouvelles méthodes ont été appliquées à la simulation d'écoulements fluides compressibles autour de géometries complexes en deux et trois dimensions d'espace.

Page generated in 0.0287 seconds