• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 11
  • Tagged with
  • 11
  • 11
  • 10
  • 9
  • 9
  • 9
  • 9
  • 9
  • 9
  • 9
  • 9
  • 8
  • 7
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Comparação de métodos de imagem do disco óptico e da camada de fibras nervosas da retina para o diagnóstico do glaucoma / Comparison of optic disc and retinal nerve fiber layer imaging methods for glaucoma diagnosis

Medeiros, Felipe de Araujo Andrade 02 June 2005 (has links)
Alterações no aspecto do disco óptico e da camada de fibras nervosas da retina (CFN) freqüentemente precedem o aparecimento de defeitos de campo visual no glaucoma, o que faz com que a avaliação destas estruturas seja essencial para o diagnóstico precoce e prevenção da perda visual nesta doença. A polarimetria de varredura a laser (GDx VCC), a oftalmoscopia confocal de varredura a laser (HRT II [Heidelberg Retina Tomograph]) e a tomografia de coerência óptica (Stratus OCT) são tecnologias que permitem a avaliação objetiva e quantitativa do disco óptico e da CFN. No presente estudo, estas tecnologias foram comparadas em sua habilidade para diferenciar pacientes glaucomatosos de indivíduos normais. Pacientes com glaucoma foram selecionados com base na presença de defeitos reprodutíveis de campo visual na perimetria acromática automatizada (glaucoma perimétrico), ou com base na evidência documentada de progressão do dano glaucomatoso ao disco óptico, sem presença de defeitos de campo visual (glaucoma pré-perimétrico). Indivíduos normais apresentaram campos visuais e exame clínico dentro da normalidade. Todos os indivíduos foram submetidos a exames com o GDx VCC, HRT II, Stratus OCT e campo visual dentro de um período de três meses. Diversas medidas foram utilizadas para avaliação da acurácia diagnóstica, incluindo áreas sob as curvas receiver operating characteristic (AROC), sensibilidades para especificidades fixas, e razões de probabilidade. Modelos estatísticos foram utilizados para avaliação da influência da severidade do glaucoma e tamanho do disco óptico na performance diagnóstica dos diferentes instrumentos. Um olho de cada indivíduo foi utilizado para análise. Dos 258 sujeitos inicialmente avaliados, 33 (13%) foram posteriormente excluídos por apresentarem imagens de baixa qualidade em pelo menos um dos aparelhos, restando 225 indivíduos (133 glaucomatosos e 92 normais) para análise. Na comparação entre os parâmetros de cada instrumento com maiores valores de AROC, o parâmetro do GDx VCC, Nerve Fiber Indicator (NFI; AROC = 0,91), e o parâmetro do Stratus OCT, Espessura Média (AROC = 0,90), apresentaram áreas sob as curvas ROC significativamente superiores à do parâmetro do HRT II, função discriminante de Bathija (AROC = 0,84). A severidade do defeito de campo visual exerceu influência significativa sob a acurácia diagnóstica dos três instrumentos, com melhora no poder diagnóstico em casos mais avançados da doença. Para o GDx VCC e Stratus OCT, o aumento no tamanho do disco óptico foi associado à diminuição na sensibilidade para detecção do glaucoma; enquanto que, para o HRT II, diminuição no tamanho do disco óptico foi associada à diminuição na sensibilidade. Razões de probabilidade para resultados anormais nas xxv classificações finais de cada instrumento foram associadas a grandes efeitos de mudança na probabilidade pós-teste em relação à probabilidade préteste, sugerindo que o encontro de um resultado anormal em qualquer um destes testes, durante a avaliação de um paciente com suspeita de glaucoma, tem impacto significativo em aumentar a probabilidade de que a doença esteja presente. Além disso, os resultados obtidos na avaliação de pacientes com glaucoma pré-perimétrico sugerem que todos os três instrumentos sejam capazes de detectar alterações estruturais precoces no glaucoma, antes do aparecimento de defeitos de campo visual na perimetria acromática / Changes in the structural appearance of the optic nerve head (ONH) and retinal nerve fiber layer (RNFL) have been reported to precede the development of visual field loss in glaucoma. Detection of ONH and RNFL damage is therefore crucial for early diagnosis of glaucoma and prevention of functional loss from the disease. Scanning laser polarimetry (GDx VCC), confocal scanning laser ophthalmoscopy (HRT II [Heidelberg Retina Tomograph]) and optical coherence tomography (Stratus OCT) are different technologies capable of providing objective and quantitative information related to these structures. The purpose of the present study was to compare, in a single population, the diagnostic abilities of these technologies in the discrimination of glaucomatous patients from healthy subjects. Glaucoma patients were selected based on the presence of repeatable visual field defects, as identified by standard automated perimetry (perimetric glaucoma), or documented evidence of progressive damage to the optic disc, in the absence of detectable visual field loss (preperimetric glaucoma). Normal subjects had normal visual fields and normal clinical examination. All subjects underwent imaging with the GDx VCC, HRT II and Stratus OCT within a 3-month period. Several measures were used for evaluation of diagnostic accuracy, including the area under the receiver operating characteristic curve (AROC), sensitivities at fixed specifities, and likelihood ratios. Statistical models were used to evaluate the influence of glaucoma severity and optic disc size on the diagnostic performance of the different instruments. One eye of each individual was randomly selected for statistical analysis. From an initial group of 258 eligible subjects, 33 (13%) had images of unacceptable quality, leaving 133 glaucoma patients and 92 healthy subjects for further analysis. In the comparison of the parameters with highest values of AROC from each instrument, the GDx VCC Nerve Fiber Indicator (AROC = 0.91) and the Stratus OCT Average Thickness (AROC = 0.90) perfomed significanlty better than the HRT II Bathija discriminant function (AROC = 0.84). For all instruments, the diagnostic accuracy increased with increasing severity of visual field defects. For the GDx VCC and Stratus OCT parameters, an increase in the size of the optic disc was related to a decrease in the sensitivity for glaucoma detection. An opposite effect was observed with the HRT II: a decrease in the size of the optic disc was related to a decrease in the sensitivity for glaucoma diagnosis. Abnormal results for each of the instruments were associated with strong positive likelihood ratios, indicating a large change from prestest to posttest probability of glaucoma. These results suggest that the finding of an abnormal result in any of these tests, when assessing a patient suspect of having glaucoma, would substantially raise the probability of disease. Results of the evaluation of patients with preperimetric glaucoma also suggest that all three instruments are able to detect early glaucomatous structural damage in the absence of visual field loss
2

Valor preditivo da topografia de disco óptico para o desenvolvimento de glaucoma / Predictive value of optic disc topography for the development of glaucoma

Alencar, Luciana Pereira Malta de 18 July 2011 (has links)
Objetivos: Analisar o potencial da oftalmoscopia confocal de varredura a laser, através do Heidelberg Retina Tomograph (HRT), para predizer o risco de progressão em pacientes com suspeita de glaucoma. Comparar os resultados obtidos com o índice de probabilidade de glaucoma (GPS) do HRT aos resultados da análise de regressão de Moorfields (ARM), dos parâmetros morfométricos e da avaliação das fotografias estereoscópicas. Métodos: Uma coorte foi selecionada com 223 pacientes com suspeita de glaucoma, que foram seguidos por um período médio de 64,9 ± 37,3 meses. A suspeita de glaucoma baseou-se na aparência do disco óptico e/ou na pressão intraocular elevada (> 21 mmHg). Todos os participantes apresentavam dois exames de campo visual normais ao entrar no estudo. Conceituou-se progressão como o desenvolvimento de um defeito confirmado de campo visual ou deterioração do disco óptico na avaliação seriada das estereofotografias. A associação entre os resultados do HRT na época do início do acompanhamento e a progressão para glaucoma foi investigada através de modelos de regressão do tipo Cox. Usou-se o C-index para a comparação entre os modelos com os diversos parâmetros do HRT, isolados ou ajustados para os outros já conhecidos fatores de risco para progressão (idade, espessura corneana, pressão intraocular e pattern standard deviation PSD). Resultados: No período do estudo, 46 pacientes (21%) apresentaram progressão. Na análise multivariada, o GPS, a ARM e diversos parâmetros morfométricos foram preditivos para progressão, assim como a avaliação subjetiva das estereofotografias. Cada GPS 0,1 maior foi associado com um aumento de 23% no risco de progressão (C-index de 0,69). Os resultados anormais nas classificações finais do GPS e da ARM foram associados a aumentos de 3 e 2 vezes no risco de progressão, respectivamente (C-indexes de 0,70 e 0,68, respectivamente). O parâmetro com o melhor C-index foi a área seccional tranversa da camada de fibras nervosas (0,72). Uma área 0,3 mm2 menor foi associada a um risco 62% maior de progressão. A comparação do valor preditivo entre os modelos com o GPS e com a avaliação subjetiva das estereofotografias foi similar (C-indexes de 0,69 e 0,68, respectivamente). Conclusão: Nesse estudo observamos que as análises objetivas do disco óptico e da região peripapilar obtidas com o HRT contribuíram na avaliação do risco de progressão em pacientes com suspeita de glaucoma. O GPS mostrou-se tão eficaz quanto os parâmetros morfométricos e a análise de regressão de Moorfields, e a comparação do desempenho dos modelos contendo a avaliação subjetiva das estereofotografias e aqueles contendo a avaliação objetiva pelo GPS não mostrou diferenças significativas / Purpose: To evaluate the ability of baseline confocal scanning laser ophthalmoscopy, using the Heidelberg Retina Tomograph (HRT), in predicting the development of progression in patients suspected of having glaucoma. In addition, the study also aimed to compare the predictive abilities of the glaucoma probability score (GPS) with those of the Moorfields regression analysis (MRA) and stereometric parameters, and to compare the performance of the HRT with that of subjective evaluation of optic disc stereophotographs. Methods: This longitudinal study included a cohort of 223 eyes suspected of having glaucoma, which were followed for an average of 64.9 ± 37.3 months. Included suspects had a suspicious appearance of the optic disc and/or elevated intraocular pressure, but normal visual fields. Progression was defined as the development of either repeatable abnormal visual fields or glaucomatous structural deterioration in the appearance of the optic disc during the study period. The association between baseline HRT parameters and progression was investigated by Cox regression models. The comparison between models with HRT parameters, individually or combined with other known risk factors (age, central corneal thickness, pattern standard deviation and intraocular pressure), performed by comparing their C-indexes. Results: Forty-six (21%) eyes converted during the study period. In multivariable models, the GPS, the MRA, and the stereometric parameters were all predictive of progression. A GPS 0.1 larger was associated with an increase of 23% in the risk of progression (C-index of 0.69). Abnormal final classifications for the GPS or the MRA were associated with a three-fold and two-fold increase in the risk of progression, respectively (with C-indexes of 0.70 and 0.68, respectively). The parameter with the best C-index was the nerve fiber layer cross-sectional area (0.72). An area 0.3 mm2 smaller was associated with a 62% higher risk of an individual progress. The comparison between models with the HRT parameters and those with the subjective stereophotograph evaluation had similar results (C-indexes of 0.69 and 0.68, respectively). Conclusion: In this study, we were able to show that the objective structural assessment of the optic disc and peripapillary area obtained with the HRT was significantly predictive for progression in suspected individuals. The GPS was as predictive as the other HRT parameters, and no significant differences were observed between models with the GPS and those with the subjective assessment of the stereophotographs.
3

Avaliação dos aspectos morfológicos dos olhos normais e dos olhos com fechamento angular primário antes e após a realização da iridotomia: comparação através da gonioscopia, biometria e biomicroscopia ultra-sônica / Ultrasonographic biomicroscopy, conventional ultrasonography, and gonioscopy exams in normal and primary angle closure eyes before and after laser iridotomy

Sakata, Lisandro Massanori 28 October 2005 (has links)
INTRODUÇÃO: O glaucoma de ângulo fechado é reconhecido como uma das principais causas de cegueira mundial. A iridotomia representa o tratamento de eleição nos casos com fechamento angular primário, entretanto, este procedimento pode não ser suficiente para proporcionar abertura do ângulo irido-corneano, controle da pressão intra-ocular (PIO) e estabilização do processo da lesão glaucomatosa. O presente estudo tem como objetivo avaliar a morfologia do segmento anterior do olho em uma amostra de pacientes brasileiros, e realizar uma comparação entre olhos normais (sem sinais de fechamento angular prévio) e olhos com ângulos oclusíveis, antes e após a realização da iridotomia. MÉTODOS: Realizou-se um estudo prospectivo observacional tipo caso-controle em pacientes da Clínica Oftalmológica do HC - FMUSP, onde 40 olhos com ângulos oclusíveis (grupo caso) e 27 olhos normais (grupo controle) foram examinados durante o período de agosto de 2003 a dezembro de 2004. Os pacientes do grupo controle foram pareados por idade, sexo e raça. Os exames de gonioscopia e biometria ultra-sônica foram utilizados para comparar os 27 olhos normais com os 40 olhos com ângulos oclusíveis, antes e após a realização da iridotomia. A biometria ultra-sônica mediu o comprimento axial do olho (CAX), a profundidade da câmara anterior (PCA) e o diâmetro ântero-posterior do cristalino (DAPC). Os 27 olhos do grupo controle foram comparados, através da biomicroscopia ultra-sônica, antes e após a iridotomia com os 31 olhos do grupo caso, que não apresentavam goniosinéquias no quadrante inferior. As imagens da UBM foram obtidas em cortes radiais sobre típicos processos ciliares, no claro e no escuro. A distância da abertura angular a 500?m do esporão escleral (DAA500), profundidade da câmara anterior (PCA-UBM), distância do trabeculado aos processos ciliares (DTPC), espessura da íris a 500?m do esporão escleral (EI500) e distância do esporão escleral à inserção da íris (linha X) foram medidas nas imagens da UBM obtidas às 6 horas. As freqüências de processos ciliares longos sem sulco ciliar e fechamento angular aposicional no escuro também foram determinadas nessas imagens. RESULTADOS: Os parâmetros morfológicos dos 27 olhos do grupo controle apresentaram diferenças significativas quando comparados com os 40 olhos do grupo caso. Os olhos normais apresentaram ângulo irido-corneano mais aberto, menor DAPC e maiores CAX e PCA. Nas imagens da UBM os 27 olhos normais apresentaram maior DAA500, PCA-UBM, linha X, e também, maior DTPC que os 31 olhos com ângulos oclusíveis (651 ± 119 ?m e 508 ± 116 ?m; p < 0.001); porém, a EI500 não apresentou diferença significativa entre os dois grupos. Após a realização da iridotomia foi observado uma abertura significativa do seio camerular, e uma diminuição da freqüência de fechamento angular aposicional nas imagens da UBM obtidas no escuro (28/31 para 16/31). Processos ciliares longos sem sulco ciliar foram observados em 61% (19/31) dos olhos do grupo caso após a iridotomia e em 33% (9/27) dos olhos do grupo controle. CONCLUSÃO: A presença de processos ciliares longos sem sulco ciliar foi um achado comum não somente nos olhos com ângulos oclusíveis como também nos olhos normais. No entanto, nos olhos do grupo caso, os processos ciliares estavam localizados, em média, numa posição mais anterior. Após a iridotomia, mais da metade dos olhos com ângulos oclusíveis continuaram apresentando fechamento angular aposicional na UBM. Os valores preditivos da presença de fechamento angular aposicional (associada ou não a processos ciliares longos sem sulco ciliar) na detecção de pacientes sob risco de apresentarem episódios de fechamento angular precisam ser avaliados em estudos futuros / Introduction: Angle closure glaucoma is emerging as one of the leading cause of worldwide blindness. Laser iridotomy (LI) has been proposed as first line therapy for patients with angle closure, however this procedure may not be effective opening the irido-corneal angle, controlling intra-ocular pressure (IOP) and halting glaucoma progression in all cases. Our study aimed to evaluate anterior segment morphology on a cohort of Brazilian patients comparing normal eyes (no signs of angle closure) to angle closure eyes before and after LI. Methods: In this prospective observational case control study, performed from August of 2003 to December of 2004, we evaluated 40 angle closure eyes and 27 normal control eyes with no signs of angle closure at clinical exam, paired by age, race and gender. We used gonioscopy and A-scan biometry to compare anterior segment morphology of 27 normal control eyes to 40 angle closure eyes of patients from our service, before and after LI. We also used ultrasound biomicroscopy (UBM) exam, to compare 27 normal control eyes to 31 of 40 angle closure eyes with no goniosynachiae at the inferior quadrant evaluated by gonioscopy, before and after LI. Immersion 50-MHz high-frequency ultrasound transducer was used to obtain UBM images in radial scans through a typical ciliary process, in both standard light and dark conditions. A-scan biometry measured axial length (AXL), anterior chamber depth (ACD) and lens thickness (LENS). The angle opening distance at 500?m from the scleral spur (AOD500), trabecular ciliary process distance (TCPD), iris thickness at 500?m and the distance from scleral spur to iris insertion (line X) were measured at UBM images obtained at the inferior quadrant. The frequency of appositional angle closure and the presence of long ciliary process with no ciliary sulcus were also evaluated at UBM images. Results: At gonioscopy and A-scan biometry exam, 27 normal eyes had a significant wider iridocorneal angle opening, a thinner LENS and a greater AXL, ACD than angle closure eyes. At UBM exam, 27 normal control eyes had an significant wider AOD500, line X and also, a longer TCPD than angle closure eyes (651 ± 119 ?m vs. 508 ± 116 ?m; p < 0.001); however no differences were observed in iris thickness between the two groups. After LI, we observed a significant irido-corneal angle opening and the number of angle closure eyes with UBM appositional angle closure in dark condition decreased from 28/31 to 16/31. A long ciliary processes with no ciliary sulcus were observed in 61% (19/31) of angle closure eyes after LI, and also in 33% (9/27) of normal control eyes. Conclusion: A long ciliary processes and absence of ciliary sulcus were a quite common finding not only in angle closure eyes, but also in normal control eyes. However, ciliary processes were located more anteriorly in angle closure eyes. On this cohort of Brazilian patients, more than half of studied eyes submitted to LI maintained UBM appositional angle closure. Whether this apposition with or without long ciliary process and absence of ciliary sulcus detected at UBM images after LI is associated to further goniosynachiae formation and/or loss of IOP control remains to be evaluated
4

Comparação entre diversas técnicas de imagem para diagnóstico do glaucoma / Comparison of different imaging techniques to diagnose glaucoma

Vessani, Roberto Murad 20 March 2008 (has links)
O objetivo desse estudo foi comparar a habilidade da avaliação subjetiva do disco óptico e da camada de fibras nervosas (CFN) por oftalmologistas generalistas e por um glaucomatólogo com medidas objetivas pela tomografia de coerência óptica (Stratus OCT), oftalmoscopia confocal de varredura a laser (HRTIII), e a polarimetria de varredura a laser (GDxECC) para discriminar olhos glaucomatosos de olhos normais. 61 olhos glaucomatosos e 57 olhos normais de 118 indivíduos foram incluídos nesse estudo. Três oftalmologistas generalistas independentes e um glaucomatólogo avaliaram fotografias estereoscópicas do disco óptico. Curvas ROC (Receiver Operator Characteristic) foram construídas para cada técnica de imagem e a sensibilidade a uma especificidade fixa foi determinada. Comparações das áreas sob essas curvas (AROC) e a concordância (k) foram determinadas entre a graduação das fotografias estereoscópicas e o melhor parâmetro de cada exame de imagem computadorizado. O melhor parâmetro de cada técnica de imagem computadorizada (CFN temporal inferior do Stratus OCT = 0,92; área integrada vertical da topografia do disco óptico pelo Stratus OCT = 0,86; espessura macular do setor inferior externo fornecido pelo Stratus OCT = 0,82; NFI do GDxECC = 0,91; razão área E/D do HRT3 = 0,83) mostrou AROC maior do que a graduação das fotografias estereoscópicas por oftalmologistas generalistas (0,80) para separar olhos glaucomatosos de olhos normais. A graduação por glaucomatólogo forneceu AROC igual ou maior (0,92) do que o melhor parâmetro de exame computadorizado de imagem. A avaliação das fotografias estereoscópicas por glaucomatólogo mostrou melhor concordância com o melhor parâmetro de cada técnica de imagem quantitativa na classificação de olhos como glaucomatosos ou normais comparadas à avaliação de fotografias estereoscópicas por oftalmologistas generalistas. A combinação da avaliação subjetiva do disco óptico por oftalmologistas generalistas com parâmetros objetivos da CFN melhorou a identificação de olhos com glaucoma em uma proporção maior do que a combinação desses parâmetros objetivos com a avaliação do disco óptico por um glaucomatólogo (29,5% versus 19,7%, respectivamente). Os resultados sugerem que a habilidade diagnóstica de todos os exames de imagem computadorizados estudados mostrou melhor desempenho que a avaliação subjetiva do disco óptico por oftalmologistas generalistas, mas não por um glaucomatólogo. Medidas objetivas da CFN podem permitir um aperfeiçoamento na detecção de glaucoma quando combinados com a avaliação subjetiva do disco óptico por oftalmologistas generalistas ou por um glaucomatólogo. / The purpose of this study was to compare the ability of subjective assessment of optic nerve head and retinal nerve fiber layer by general ophthalmologists and by a glaucoma expert with objective measurements by optical coherence tomography (Stratus OCT, Carl Zeiss Meditec, Inc.), confocal scanning laser ophthalmoscope (HRT III; Heidelberg Engineering, Heidelberg, Germany), and scanning laser polarimetry (GDx ECC; Carl Zeiss Meditec, Inc., Dublin, CA) in discriminating glaucomatous and normal eyes. 61 glaucomatous and 57 normal eyes of 118 subjects were included in the study. Three independent general ophthalmologists and one glaucoma expert evaluated ONH stereophotographs. Receiver operating characteristic curves were constructed for each imaging technique and sensitivity at fixed specificity was estimated. Comparisons of areas under these curves (aROC) and agreement (k) were determined between stereophoto grading and best parameter from each technique. Best parameter from each technique showed larger aROC (StratusOCT RNFL = 0.92; StratusOCT ONH vertical integrated area = 0.86; StratusOCT macular thickness = 0.82; GDxECC = 0.91; HRT3 global cup-to-disc area ratio = 0.83) compared to stereophotograph grading by general ophthalmologists (0.80) in separating glaucomatous and normal eyes. Glaucoma expert stereophoto grading provided equal or larger aROC (0.92) than best parameter of each computerized imaging device. Stereophoto evaluated by a glaucoma expert showed better agreement with best parameter of each quantitative imaging technique in classifying eyes either as glaucomatous or normal compared to stereophoto grading by general ophthalmologists. The combination of subjective assessment of the optic disc by general ophthalmologists with RNFL objective parameters improved identification of glaucoma patients in a larger proportion than the combination of these objective parameters with subjective assessment of the optic disc by a glaucoma expert (29.5% versus 19.7%, respectively). The results suggests that the diagnostic ability of all imaging techniques showed better performance than subjective assessment of the ONH by general ophthalmologists, but not by a glaucoma expert. Objective RNFL measurements may provide improvement in glaucoma detection when combined with subjective assessment of the optic disc by general ophthalmologists or by a glaucoma expert.
5

Avaliação dos aspectos morfológicos dos olhos normais e dos olhos com fechamento angular primário antes e após a realização da iridotomia: comparação através da gonioscopia, biometria e biomicroscopia ultra-sônica / Ultrasonographic biomicroscopy, conventional ultrasonography, and gonioscopy exams in normal and primary angle closure eyes before and after laser iridotomy

Lisandro Massanori Sakata 28 October 2005 (has links)
INTRODUÇÃO: O glaucoma de ângulo fechado é reconhecido como uma das principais causas de cegueira mundial. A iridotomia representa o tratamento de eleição nos casos com fechamento angular primário, entretanto, este procedimento pode não ser suficiente para proporcionar abertura do ângulo irido-corneano, controle da pressão intra-ocular (PIO) e estabilização do processo da lesão glaucomatosa. O presente estudo tem como objetivo avaliar a morfologia do segmento anterior do olho em uma amostra de pacientes brasileiros, e realizar uma comparação entre olhos normais (sem sinais de fechamento angular prévio) e olhos com ângulos oclusíveis, antes e após a realização da iridotomia. MÉTODOS: Realizou-se um estudo prospectivo observacional tipo caso-controle em pacientes da Clínica Oftalmológica do HC - FMUSP, onde 40 olhos com ângulos oclusíveis (grupo caso) e 27 olhos normais (grupo controle) foram examinados durante o período de agosto de 2003 a dezembro de 2004. Os pacientes do grupo controle foram pareados por idade, sexo e raça. Os exames de gonioscopia e biometria ultra-sônica foram utilizados para comparar os 27 olhos normais com os 40 olhos com ângulos oclusíveis, antes e após a realização da iridotomia. A biometria ultra-sônica mediu o comprimento axial do olho (CAX), a profundidade da câmara anterior (PCA) e o diâmetro ântero-posterior do cristalino (DAPC). Os 27 olhos do grupo controle foram comparados, através da biomicroscopia ultra-sônica, antes e após a iridotomia com os 31 olhos do grupo caso, que não apresentavam goniosinéquias no quadrante inferior. As imagens da UBM foram obtidas em cortes radiais sobre típicos processos ciliares, no claro e no escuro. A distância da abertura angular a 500?m do esporão escleral (DAA500), profundidade da câmara anterior (PCA-UBM), distância do trabeculado aos processos ciliares (DTPC), espessura da íris a 500?m do esporão escleral (EI500) e distância do esporão escleral à inserção da íris (linha X) foram medidas nas imagens da UBM obtidas às 6 horas. As freqüências de processos ciliares longos sem sulco ciliar e fechamento angular aposicional no escuro também foram determinadas nessas imagens. RESULTADOS: Os parâmetros morfológicos dos 27 olhos do grupo controle apresentaram diferenças significativas quando comparados com os 40 olhos do grupo caso. Os olhos normais apresentaram ângulo irido-corneano mais aberto, menor DAPC e maiores CAX e PCA. Nas imagens da UBM os 27 olhos normais apresentaram maior DAA500, PCA-UBM, linha X, e também, maior DTPC que os 31 olhos com ângulos oclusíveis (651 ± 119 ?m e 508 ± 116 ?m; p < 0.001); porém, a EI500 não apresentou diferença significativa entre os dois grupos. Após a realização da iridotomia foi observado uma abertura significativa do seio camerular, e uma diminuição da freqüência de fechamento angular aposicional nas imagens da UBM obtidas no escuro (28/31 para 16/31). Processos ciliares longos sem sulco ciliar foram observados em 61% (19/31) dos olhos do grupo caso após a iridotomia e em 33% (9/27) dos olhos do grupo controle. CONCLUSÃO: A presença de processos ciliares longos sem sulco ciliar foi um achado comum não somente nos olhos com ângulos oclusíveis como também nos olhos normais. No entanto, nos olhos do grupo caso, os processos ciliares estavam localizados, em média, numa posição mais anterior. Após a iridotomia, mais da metade dos olhos com ângulos oclusíveis continuaram apresentando fechamento angular aposicional na UBM. Os valores preditivos da presença de fechamento angular aposicional (associada ou não a processos ciliares longos sem sulco ciliar) na detecção de pacientes sob risco de apresentarem episódios de fechamento angular precisam ser avaliados em estudos futuros / Introduction: Angle closure glaucoma is emerging as one of the leading cause of worldwide blindness. Laser iridotomy (LI) has been proposed as first line therapy for patients with angle closure, however this procedure may not be effective opening the irido-corneal angle, controlling intra-ocular pressure (IOP) and halting glaucoma progression in all cases. Our study aimed to evaluate anterior segment morphology on a cohort of Brazilian patients comparing normal eyes (no signs of angle closure) to angle closure eyes before and after LI. Methods: In this prospective observational case control study, performed from August of 2003 to December of 2004, we evaluated 40 angle closure eyes and 27 normal control eyes with no signs of angle closure at clinical exam, paired by age, race and gender. We used gonioscopy and A-scan biometry to compare anterior segment morphology of 27 normal control eyes to 40 angle closure eyes of patients from our service, before and after LI. We also used ultrasound biomicroscopy (UBM) exam, to compare 27 normal control eyes to 31 of 40 angle closure eyes with no goniosynachiae at the inferior quadrant evaluated by gonioscopy, before and after LI. Immersion 50-MHz high-frequency ultrasound transducer was used to obtain UBM images in radial scans through a typical ciliary process, in both standard light and dark conditions. A-scan biometry measured axial length (AXL), anterior chamber depth (ACD) and lens thickness (LENS). The angle opening distance at 500?m from the scleral spur (AOD500), trabecular ciliary process distance (TCPD), iris thickness at 500?m and the distance from scleral spur to iris insertion (line X) were measured at UBM images obtained at the inferior quadrant. The frequency of appositional angle closure and the presence of long ciliary process with no ciliary sulcus were also evaluated at UBM images. Results: At gonioscopy and A-scan biometry exam, 27 normal eyes had a significant wider iridocorneal angle opening, a thinner LENS and a greater AXL, ACD than angle closure eyes. At UBM exam, 27 normal control eyes had an significant wider AOD500, line X and also, a longer TCPD than angle closure eyes (651 ± 119 ?m vs. 508 ± 116 ?m; p < 0.001); however no differences were observed in iris thickness between the two groups. After LI, we observed a significant irido-corneal angle opening and the number of angle closure eyes with UBM appositional angle closure in dark condition decreased from 28/31 to 16/31. A long ciliary processes with no ciliary sulcus were observed in 61% (19/31) of angle closure eyes after LI, and also in 33% (9/27) of normal control eyes. Conclusion: A long ciliary processes and absence of ciliary sulcus were a quite common finding not only in angle closure eyes, but also in normal control eyes. However, ciliary processes were located more anteriorly in angle closure eyes. On this cohort of Brazilian patients, more than half of studied eyes submitted to LI maintained UBM appositional angle closure. Whether this apposition with or without long ciliary process and absence of ciliary sulcus detected at UBM images after LI is associated to further goniosynachiae formation and/or loss of IOP control remains to be evaluated
6

Comparação de métodos de imagem do disco óptico e da camada de fibras nervosas da retina para o diagnóstico do glaucoma / Comparison of optic disc and retinal nerve fiber layer imaging methods for glaucoma diagnosis

Felipe de Araujo Andrade Medeiros 02 June 2005 (has links)
Alterações no aspecto do disco óptico e da camada de fibras nervosas da retina (CFN) freqüentemente precedem o aparecimento de defeitos de campo visual no glaucoma, o que faz com que a avaliação destas estruturas seja essencial para o diagnóstico precoce e prevenção da perda visual nesta doença. A polarimetria de varredura a laser (GDx VCC), a oftalmoscopia confocal de varredura a laser (HRT II [Heidelberg Retina Tomograph]) e a tomografia de coerência óptica (Stratus OCT) são tecnologias que permitem a avaliação objetiva e quantitativa do disco óptico e da CFN. No presente estudo, estas tecnologias foram comparadas em sua habilidade para diferenciar pacientes glaucomatosos de indivíduos normais. Pacientes com glaucoma foram selecionados com base na presença de defeitos reprodutíveis de campo visual na perimetria acromática automatizada (glaucoma perimétrico), ou com base na evidência documentada de progressão do dano glaucomatoso ao disco óptico, sem presença de defeitos de campo visual (glaucoma pré-perimétrico). Indivíduos normais apresentaram campos visuais e exame clínico dentro da normalidade. Todos os indivíduos foram submetidos a exames com o GDx VCC, HRT II, Stratus OCT e campo visual dentro de um período de três meses. Diversas medidas foram utilizadas para avaliação da acurácia diagnóstica, incluindo áreas sob as curvas receiver operating characteristic (AROC), sensibilidades para especificidades fixas, e razões de probabilidade. Modelos estatísticos foram utilizados para avaliação da influência da severidade do glaucoma e tamanho do disco óptico na performance diagnóstica dos diferentes instrumentos. Um olho de cada indivíduo foi utilizado para análise. Dos 258 sujeitos inicialmente avaliados, 33 (13%) foram posteriormente excluídos por apresentarem imagens de baixa qualidade em pelo menos um dos aparelhos, restando 225 indivíduos (133 glaucomatosos e 92 normais) para análise. Na comparação entre os parâmetros de cada instrumento com maiores valores de AROC, o parâmetro do GDx VCC, Nerve Fiber Indicator (NFI; AROC = 0,91), e o parâmetro do Stratus OCT, Espessura Média (AROC = 0,90), apresentaram áreas sob as curvas ROC significativamente superiores à do parâmetro do HRT II, função discriminante de Bathija (AROC = 0,84). A severidade do defeito de campo visual exerceu influência significativa sob a acurácia diagnóstica dos três instrumentos, com melhora no poder diagnóstico em casos mais avançados da doença. Para o GDx VCC e Stratus OCT, o aumento no tamanho do disco óptico foi associado à diminuição na sensibilidade para detecção do glaucoma; enquanto que, para o HRT II, diminuição no tamanho do disco óptico foi associada à diminuição na sensibilidade. Razões de probabilidade para resultados anormais nas xxv classificações finais de cada instrumento foram associadas a grandes efeitos de mudança na probabilidade pós-teste em relação à probabilidade préteste, sugerindo que o encontro de um resultado anormal em qualquer um destes testes, durante a avaliação de um paciente com suspeita de glaucoma, tem impacto significativo em aumentar a probabilidade de que a doença esteja presente. Além disso, os resultados obtidos na avaliação de pacientes com glaucoma pré-perimétrico sugerem que todos os três instrumentos sejam capazes de detectar alterações estruturais precoces no glaucoma, antes do aparecimento de defeitos de campo visual na perimetria acromática / Changes in the structural appearance of the optic nerve head (ONH) and retinal nerve fiber layer (RNFL) have been reported to precede the development of visual field loss in glaucoma. Detection of ONH and RNFL damage is therefore crucial for early diagnosis of glaucoma and prevention of functional loss from the disease. Scanning laser polarimetry (GDx VCC), confocal scanning laser ophthalmoscopy (HRT II [Heidelberg Retina Tomograph]) and optical coherence tomography (Stratus OCT) are different technologies capable of providing objective and quantitative information related to these structures. The purpose of the present study was to compare, in a single population, the diagnostic abilities of these technologies in the discrimination of glaucomatous patients from healthy subjects. Glaucoma patients were selected based on the presence of repeatable visual field defects, as identified by standard automated perimetry (perimetric glaucoma), or documented evidence of progressive damage to the optic disc, in the absence of detectable visual field loss (preperimetric glaucoma). Normal subjects had normal visual fields and normal clinical examination. All subjects underwent imaging with the GDx VCC, HRT II and Stratus OCT within a 3-month period. Several measures were used for evaluation of diagnostic accuracy, including the area under the receiver operating characteristic curve (AROC), sensitivities at fixed specifities, and likelihood ratios. Statistical models were used to evaluate the influence of glaucoma severity and optic disc size on the diagnostic performance of the different instruments. One eye of each individual was randomly selected for statistical analysis. From an initial group of 258 eligible subjects, 33 (13%) had images of unacceptable quality, leaving 133 glaucoma patients and 92 healthy subjects for further analysis. In the comparison of the parameters with highest values of AROC from each instrument, the GDx VCC Nerve Fiber Indicator (AROC = 0.91) and the Stratus OCT Average Thickness (AROC = 0.90) perfomed significanlty better than the HRT II Bathija discriminant function (AROC = 0.84). For all instruments, the diagnostic accuracy increased with increasing severity of visual field defects. For the GDx VCC and Stratus OCT parameters, an increase in the size of the optic disc was related to a decrease in the sensitivity for glaucoma detection. An opposite effect was observed with the HRT II: a decrease in the size of the optic disc was related to a decrease in the sensitivity for glaucoma diagnosis. Abnormal results for each of the instruments were associated with strong positive likelihood ratios, indicating a large change from prestest to posttest probability of glaucoma. These results suggest that the finding of an abnormal result in any of these tests, when assessing a patient suspect of having glaucoma, would substantially raise the probability of disease. Results of the evaluation of patients with preperimetric glaucoma also suggest that all three instruments are able to detect early glaucomatous structural damage in the absence of visual field loss
7

Valor preditivo da topografia de disco óptico para o desenvolvimento de glaucoma / Predictive value of optic disc topography for the development of glaucoma

Luciana Pereira Malta de Alencar 18 July 2011 (has links)
Objetivos: Analisar o potencial da oftalmoscopia confocal de varredura a laser, através do Heidelberg Retina Tomograph (HRT), para predizer o risco de progressão em pacientes com suspeita de glaucoma. Comparar os resultados obtidos com o índice de probabilidade de glaucoma (GPS) do HRT aos resultados da análise de regressão de Moorfields (ARM), dos parâmetros morfométricos e da avaliação das fotografias estereoscópicas. Métodos: Uma coorte foi selecionada com 223 pacientes com suspeita de glaucoma, que foram seguidos por um período médio de 64,9 ± 37,3 meses. A suspeita de glaucoma baseou-se na aparência do disco óptico e/ou na pressão intraocular elevada (> 21 mmHg). Todos os participantes apresentavam dois exames de campo visual normais ao entrar no estudo. Conceituou-se progressão como o desenvolvimento de um defeito confirmado de campo visual ou deterioração do disco óptico na avaliação seriada das estereofotografias. A associação entre os resultados do HRT na época do início do acompanhamento e a progressão para glaucoma foi investigada através de modelos de regressão do tipo Cox. Usou-se o C-index para a comparação entre os modelos com os diversos parâmetros do HRT, isolados ou ajustados para os outros já conhecidos fatores de risco para progressão (idade, espessura corneana, pressão intraocular e pattern standard deviation PSD). Resultados: No período do estudo, 46 pacientes (21%) apresentaram progressão. Na análise multivariada, o GPS, a ARM e diversos parâmetros morfométricos foram preditivos para progressão, assim como a avaliação subjetiva das estereofotografias. Cada GPS 0,1 maior foi associado com um aumento de 23% no risco de progressão (C-index de 0,69). Os resultados anormais nas classificações finais do GPS e da ARM foram associados a aumentos de 3 e 2 vezes no risco de progressão, respectivamente (C-indexes de 0,70 e 0,68, respectivamente). O parâmetro com o melhor C-index foi a área seccional tranversa da camada de fibras nervosas (0,72). Uma área 0,3 mm2 menor foi associada a um risco 62% maior de progressão. A comparação do valor preditivo entre os modelos com o GPS e com a avaliação subjetiva das estereofotografias foi similar (C-indexes de 0,69 e 0,68, respectivamente). Conclusão: Nesse estudo observamos que as análises objetivas do disco óptico e da região peripapilar obtidas com o HRT contribuíram na avaliação do risco de progressão em pacientes com suspeita de glaucoma. O GPS mostrou-se tão eficaz quanto os parâmetros morfométricos e a análise de regressão de Moorfields, e a comparação do desempenho dos modelos contendo a avaliação subjetiva das estereofotografias e aqueles contendo a avaliação objetiva pelo GPS não mostrou diferenças significativas / Purpose: To evaluate the ability of baseline confocal scanning laser ophthalmoscopy, using the Heidelberg Retina Tomograph (HRT), in predicting the development of progression in patients suspected of having glaucoma. In addition, the study also aimed to compare the predictive abilities of the glaucoma probability score (GPS) with those of the Moorfields regression analysis (MRA) and stereometric parameters, and to compare the performance of the HRT with that of subjective evaluation of optic disc stereophotographs. Methods: This longitudinal study included a cohort of 223 eyes suspected of having glaucoma, which were followed for an average of 64.9 ± 37.3 months. Included suspects had a suspicious appearance of the optic disc and/or elevated intraocular pressure, but normal visual fields. Progression was defined as the development of either repeatable abnormal visual fields or glaucomatous structural deterioration in the appearance of the optic disc during the study period. The association between baseline HRT parameters and progression was investigated by Cox regression models. The comparison between models with HRT parameters, individually or combined with other known risk factors (age, central corneal thickness, pattern standard deviation and intraocular pressure), performed by comparing their C-indexes. Results: Forty-six (21%) eyes converted during the study period. In multivariable models, the GPS, the MRA, and the stereometric parameters were all predictive of progression. A GPS 0.1 larger was associated with an increase of 23% in the risk of progression (C-index of 0.69). Abnormal final classifications for the GPS or the MRA were associated with a three-fold and two-fold increase in the risk of progression, respectively (with C-indexes of 0.70 and 0.68, respectively). The parameter with the best C-index was the nerve fiber layer cross-sectional area (0.72). An area 0.3 mm2 smaller was associated with a 62% higher risk of an individual progress. The comparison between models with the HRT parameters and those with the subjective stereophotograph evaluation had similar results (C-indexes of 0.69 and 0.68, respectively). Conclusion: In this study, we were able to show that the objective structural assessment of the optic disc and peripapillary area obtained with the HRT was significantly predictive for progression in suspected individuals. The GPS was as predictive as the other HRT parameters, and no significant differences were observed between models with the GPS and those with the subjective assessment of the stereophotographs.
8

Comparação entre diversas técnicas de imagem para diagnóstico do glaucoma / Comparison of different imaging techniques to diagnose glaucoma

Roberto Murad Vessani 20 March 2008 (has links)
O objetivo desse estudo foi comparar a habilidade da avaliação subjetiva do disco óptico e da camada de fibras nervosas (CFN) por oftalmologistas generalistas e por um glaucomatólogo com medidas objetivas pela tomografia de coerência óptica (Stratus OCT), oftalmoscopia confocal de varredura a laser (HRTIII), e a polarimetria de varredura a laser (GDxECC) para discriminar olhos glaucomatosos de olhos normais. 61 olhos glaucomatosos e 57 olhos normais de 118 indivíduos foram incluídos nesse estudo. Três oftalmologistas generalistas independentes e um glaucomatólogo avaliaram fotografias estereoscópicas do disco óptico. Curvas ROC (Receiver Operator Characteristic) foram construídas para cada técnica de imagem e a sensibilidade a uma especificidade fixa foi determinada. Comparações das áreas sob essas curvas (AROC) e a concordância (k) foram determinadas entre a graduação das fotografias estereoscópicas e o melhor parâmetro de cada exame de imagem computadorizado. O melhor parâmetro de cada técnica de imagem computadorizada (CFN temporal inferior do Stratus OCT = 0,92; área integrada vertical da topografia do disco óptico pelo Stratus OCT = 0,86; espessura macular do setor inferior externo fornecido pelo Stratus OCT = 0,82; NFI do GDxECC = 0,91; razão área E/D do HRT3 = 0,83) mostrou AROC maior do que a graduação das fotografias estereoscópicas por oftalmologistas generalistas (0,80) para separar olhos glaucomatosos de olhos normais. A graduação por glaucomatólogo forneceu AROC igual ou maior (0,92) do que o melhor parâmetro de exame computadorizado de imagem. A avaliação das fotografias estereoscópicas por glaucomatólogo mostrou melhor concordância com o melhor parâmetro de cada técnica de imagem quantitativa na classificação de olhos como glaucomatosos ou normais comparadas à avaliação de fotografias estereoscópicas por oftalmologistas generalistas. A combinação da avaliação subjetiva do disco óptico por oftalmologistas generalistas com parâmetros objetivos da CFN melhorou a identificação de olhos com glaucoma em uma proporção maior do que a combinação desses parâmetros objetivos com a avaliação do disco óptico por um glaucomatólogo (29,5% versus 19,7%, respectivamente). Os resultados sugerem que a habilidade diagnóstica de todos os exames de imagem computadorizados estudados mostrou melhor desempenho que a avaliação subjetiva do disco óptico por oftalmologistas generalistas, mas não por um glaucomatólogo. Medidas objetivas da CFN podem permitir um aperfeiçoamento na detecção de glaucoma quando combinados com a avaliação subjetiva do disco óptico por oftalmologistas generalistas ou por um glaucomatólogo. / The purpose of this study was to compare the ability of subjective assessment of optic nerve head and retinal nerve fiber layer by general ophthalmologists and by a glaucoma expert with objective measurements by optical coherence tomography (Stratus OCT, Carl Zeiss Meditec, Inc.), confocal scanning laser ophthalmoscope (HRT III; Heidelberg Engineering, Heidelberg, Germany), and scanning laser polarimetry (GDx ECC; Carl Zeiss Meditec, Inc., Dublin, CA) in discriminating glaucomatous and normal eyes. 61 glaucomatous and 57 normal eyes of 118 subjects were included in the study. Three independent general ophthalmologists and one glaucoma expert evaluated ONH stereophotographs. Receiver operating characteristic curves were constructed for each imaging technique and sensitivity at fixed specificity was estimated. Comparisons of areas under these curves (aROC) and agreement (k) were determined between stereophoto grading and best parameter from each technique. Best parameter from each technique showed larger aROC (StratusOCT RNFL = 0.92; StratusOCT ONH vertical integrated area = 0.86; StratusOCT macular thickness = 0.82; GDxECC = 0.91; HRT3 global cup-to-disc area ratio = 0.83) compared to stereophotograph grading by general ophthalmologists (0.80) in separating glaucomatous and normal eyes. Glaucoma expert stereophoto grading provided equal or larger aROC (0.92) than best parameter of each computerized imaging device. Stereophoto evaluated by a glaucoma expert showed better agreement with best parameter of each quantitative imaging technique in classifying eyes either as glaucomatous or normal compared to stereophoto grading by general ophthalmologists. The combination of subjective assessment of the optic disc by general ophthalmologists with RNFL objective parameters improved identification of glaucoma patients in a larger proportion than the combination of these objective parameters with subjective assessment of the optic disc by a glaucoma expert (29.5% versus 19.7%, respectively). The results suggests that the diagnostic ability of all imaging techniques showed better performance than subjective assessment of the ONH by general ophthalmologists, but not by a glaucoma expert. Objective RNFL measurements may provide improvement in glaucoma detection when combined with subjective assessment of the optic disc by general ophthalmologists or by a glaucoma expert.
9

Tomografia de coerência óptica em olhos glaucomatosos com defeito assimétrico de hemicampo visual / Optical coherence tomography in glaucomatous eyes with assymetrical hemifield loss

Reis, Alexandre Soares Castro 08 November 2013 (has links)
Objetivo: Estudar as medidas de espessura da camada de fibras nervosas da retina(CFNR) peripapilar obtidas com as tomografias de coerência óptia (oCT) time domain (TD) e spectral domain (SD) em pacientes com perda assimétrica glaucomatosa de hemicampo visual, compará-las entre si e com aquelas de controles normais. Métodos: Trinta e seis pacientes com glaucoma primário de ângulo aberto e perda de campo visual em um hemicampo (afetado) e ausência de perda no hemicampo oposto (não afetado), e 36 controles pareados por idade tiveram o olho de estudo examinado com Stratus-OCT (Carl Zeiss Meditec Inc., Dublin, Califoprnia, USA) e o 3DOCT-1000 (Topcdon, Tokyo, Japan). As medidas de espessura da CFNR peripapilar e a classificação normativa fornecida pelos aparelhos foram registrados para análise. A média aritmética dos valores do mapa total deviation em cada hemicampo (mean deviation do hemicampo) foi calculada para cada indivíduo. \"Ìndices de assimetria\" para o campo visual e para a CFNR foram calculados como a razão entre o mean deviation dos hemicampos afetado e não-afetado, e como razão entre a espessura da CFNR das hemirretinas afetada e não-afetada, respectivamente. As variáveis contínuas foram comparadas usando os testes de Mann-Whitney, Kruskal-Wallis ou Wilcoxon, quando apropriados. As variáveis categóricas foram comparadas usando o teste qui-quadrado de Pearson. O coeficiente de correlação de Spearman foi usado para testar as correlações entre as medidas de espessura da CFNR fornecidas pelos OCTs. A presença de afinamento da CFNR foi estabelecida com base nos dados normativos fornecidos pelos softwares dos OCTs. As espessuras de CFNR fora do intervalo de previsão de 95% para a mesma faixa etária foram consideradas anormais. Resultados: As medidas de CFNR corespondentes a hemicampos não-afetados [média (DP) 87,0 (17,1) um e 84,3 (20,2) um, para TD e SD-OCT, respectivamente] foram menores do que as dos controles [média (DP) 119,0 (122,2)um e 117,0 (17,7) um, para TD e SD-OCT, respectivamente, P < 0,001, para ambos]. O banco de dados normativo classificou como alterado 42% e 67% das hemirretinas correspondentes a hemicampos não-acometidos com TD e SD-OCT, respectivamente (P = 0,01). As medidas da CFNR foram consistentemente mais espessas com TD comparadas com SD-OCT. Os índices de assimetria da CFNR em pacientes com glaucoma foram semelhantes entre TD [média (DP) 0,76 (0,17)] e SD-OCT [média (DP) 0,79 (0,12), P = 0,89] e significantemente maiores do que o índice de assimetria do campo visual [média (DP) 0,36 (0,20), P < 0,001]. Conclusões: Os hemicampos normais de pacientes com glaucoma apresentaram CFNR mais fina do que de olhos saudáveis. As medidas da CFNR foram mais espessas com TD do que com SD-OCT, o qual por sua vez detectou anormalidades na espessura da CFNR mais frequentemente do que o TD-OCT / Objective: To study the peripapillary retinal nerve fiber layer (RNFL) thickness measurements obtained with time domain (TD) and spectral domain (SD) optical coherence tomography (OCT) in glaucomatous patients with asymmetric visual hemifield loss, to compare themselves and with those obtained from normal controls. Methods : Thirty -six patients with primary open-angle glaucoma with visual primary open-angle glaucoma with visual field loss in one hemifield (affected ) and absence of loss in other (non-affected), and 36 age-matched healthy controls had the eye study imaged with Stratus-OCT (Carl Zeiss Meditec Inc., Dublin, Califoprnia, USA) and 3D OCT-1000 (Topcon , Tokyo, Japan). Peripapillary RNFL thickness measurements and normative classification were recorded for analysis. Total deviation values were averaged for each hemifield (hemifield mean deviation) for ecch subject. Visual field and RNFL \"asymmetry indexes\" were calculated as the ratio between the mean deviation of affected versus non-affected hemifields and RNFL thickness between as affected versus non-affected hemiretinas, respectively. Continuous variables were compared using the Mann-Whitney, Kruskal-Wallis or Wilcoxon tests, when appropriate. Categorical variables were compared using the Pearson\'s chi-square test. The Spearman\'s rank correlation coefficient was used to test correlations between RNFL thickness measurements provided by both OCTs . The presence of RNFL thinning was establised based on normative data provided by the OCT\'s software. The RNFL thicknesses outside the prediction interval of 95% for the same age group were considered abnormal. Results: The RNFL measurements in non-affected hemifields [mean (SD 87.0 (17.1) e 84.3(20.2) um, for TD and SD-OCT, respectively] were thinner than those of normal controls [mean (SD) 119.0 (12.2) um and 117.0 (17.7) um, for TD and SD-OCT, respectively, P < 0.001 for both ] . The OCT normative database classified 42 % and 67% of hemiretinas corresponding to non-affected hemifields as abnormal in TD and SD-OCT, respectively (P =0.01). The RNFL measurements were consistently thicker with TD compared with SD -OCT. The RNFL thickness asymetry index in patients with glaucoma was similar with TD [ mean (SD) 0.76 ( 0.17 ) ] and SD-OCT [ mean (SD)0.79(0.12), P = 0,89] and significantly greater than the visual field asymmetry index [ mean (SD ) 0.36 (0.20 ), P < 0.001]. Conclusions: Normal hemifields of glaucoma patients had thinner RNFL measurements than healthy eyes, as measured by TD and SD-OCT. The RNFL measurements were thicker with TD than SD-OCT, SD-OCT detected abnormal RNFL more often than TD-OCT
10

Avaliação estrutural do disco óptico e da camada de fibras nervosas retinianas peripapilares em pacientes com retinopatia diabética submetidos a panfotocoagulação retiniana / Structural evaluation of the optic disc and peripapillary retinal nerve fiber layer in patients with diabetic retinopathy submitted to panretinal photocoagulation

Azevedo, Breno Marques da Silva 04 April 2019 (has links)
Objetivos: Determinar o efeito da panfotocoagulação retiniana (PFC) nos parâmetros topográficos do disco óptico e na camada de fibras nervosas da retina (CFNR) peripapilar em pacientes com retinopatia diabética proliferativa (RDP). Métodos: Este é um estudo observacional prospectivo, de centro único. Trinta e oito olhos de 26 pacientes diabéticos foram submetidos a PFC para retinopatia diabética proliferativa. As estereofotografias (EFs) e os parâmetros do disco óptico foram avaliados usando o retinógrafo Visucam da Zeiss e a Tomografia de varredura a laser (TVL), respectivamente. A espessura da CFNR peripapilar foi medida por tomografia de coerência óptica (OCT) e polarimetria de varredura a laser (PVL). Todas as medições foram realizadas no início e 12 meses após a conclusão da PFC. Resultados: Trinta e oito olhos de 26 pacientes (15 mulheres) com média de idade de 53,7 anos (faixa etária de 26 a 74 anos) foram recrutados. Nenhuma diferença significativa foi encontrada entre a média horizontal e vertical para relação escavação/disco óptico (E/D) determinadas pelas EFs antes e após o tratamento com PFC (P = 0,461 e 0,839, respectivamente). Os valores globais dos parâmetros do disco óptico analisados com a TVL não mostraram nenhuma mudança significativa entre o baseline e 12 meses após o tratamento (área do disco, área da escavação, área da rima, volume da escavação, volume da rima, relação área da escavação/área do disco, relação linear do tamanho da escavação/disco, profundidade média da escavação, profundidade máxima da escavação, medida do formato da escavação, variação na altura do contorno, espessura média da CFNR e área transversal da CFNR). O OCT e o PVL não encontraram diferença significativa entre a CFNR peripapilar antes e após a PFC (P = 0,114 e P = 0,813, respectivamente). Conclusões: Nossos resultados sugerem que a PFC nos padrões realizados no presente estudo não causa significantes alterações morfológicas no disco óptico em pacientes diabéticos com RDP após um ano de acompanhamento / Purpose: To determine the effect of panretinal photocoagulation (PRP) on optic disc topographic parameters and peripapillary retinal nerve fiber layer (RNFL) in nonglaucomatous patients with proliferative diabetic retinopathy (PDR). Methods: This is a prospective, single center, observational study. Thirty-eight eyes of 26 diabetic patients underwent PRP for proliferative diabetic retinopathy. Stereoscopic disc photographs and optic nerve head (ONH) parameters were evaluated using the Zeiss fundus camera and the confocal scanning laser ophthalmoscopy (CSLO), respectively. The peripapillary RNFL thickness was measured by optical coherence tomography (OCT) and scanning laser polarimetry (SLP). All measurements were performed at baseline and 12 months after completion of PRP. Results: Thirty-eight eyes of 26 patients (15 female) with a mean age of 53.7 years (range 26 to 74 years) were recruited. No significant difference was found between mean horizontal and vertical cup to disc (C/D) ratio determined by stereoscopic disc photographs before and after PRP treatment (P=0.461 and 0.839, respectively). The global values of ONH parameters analyzed with the CSLO showed no significant change from baseline to 12 months (disc area, cup area, rim area, cup volume, rim volume, C/D area ratio, linear C/D ratio, mean cup depth, maximum cup depth, cup shape measure, height variation contour, mean retinal nerve fiber layer thickness and cross-sectional area). The OCT and SLP did not find significant difference between peripapillary RNFL before and after PRP (P=0.114 and P=0.813, respectively). Conclusion: Our results suggest that PRP as performed in this study does not cause significant morphological optic disk changes in diabetic PDR patients after one year of follow-up

Page generated in 0.0807 seconds