• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 11
  • Tagged with
  • 12
  • 12
  • 11
  • 11
  • 10
  • 9
  • 9
  • 9
  • 9
  • 9
  • 8
  • 7
  • 7
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Identificação automática do disco óptico em imagens coloridas da retina

Guerra, Raquel Alexandra Afonso January 2008 (has links)
Tese de mestrado. Engenharia Biomédica. Faculdade de Engenharia. Universidade do Porto. 2008
2

Comparação entre as medidas lineares da relação escavação/disco óptico obtidas com o OCT RTVue e a retinografia digital

Ribeiro Junior, Valdenir 19 November 2014 (has links)
Submitted by Erika Demachki (erikademachki@gmail.com) on 2015-05-11T20:23:53Z No. of bitstreams: 3 Dissertação - Valdenir Ribeiro Júnior - 2014.pdf: 1448512 bytes, checksum: 318b3171b4b9dbe4d3d79bea1af6ca77 (MD5) PARECER CONSUBSTANCIADO.pdf: 29881 bytes, checksum: a11bf6a7fd5e3fd476da07a1a90abf93 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Erika Demachki (erikademachki@gmail.com) on 2015-05-11T20:32:27Z (GMT) No. of bitstreams: 3 Dissertação - Valdenir Ribeiro Júnior - 2014.pdf: 1448512 bytes, checksum: 318b3171b4b9dbe4d3d79bea1af6ca77 (MD5) PARECER CONSUBSTANCIADO.pdf: 29881 bytes, checksum: a11bf6a7fd5e3fd476da07a1a90abf93 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2015-05-11T20:32:27Z (GMT). No. of bitstreams: 3 Dissertação - Valdenir Ribeiro Júnior - 2014.pdf: 1448512 bytes, checksum: 318b3171b4b9dbe4d3d79bea1af6ca77 (MD5) PARECER CONSUBSTANCIADO.pdf: 29881 bytes, checksum: a11bf6a7fd5e3fd476da07a1a90abf93 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2014-11-19 / The purpose of this study was to compare the linear measurements of the optic disc cup, obtained by RTVue OCT with those obtained by Digital Retinography. It is a cross-sectional retrospective study, conducted at VER Hospital - Excellence in Ophthalmology. Was used images from digital retinography and OCT scans obtained by an RTVue device. In the color retinography, the greatest horizontal and vertical diameters of the optic disc from the inner edge of the Elschnig ring were obtained by a pachymeter with 0.01 mm. In OCT, the delineation of optic nerve was obtained automatically and from the results the horizontal and vertical diameters of the excavation were recorded. One hundred eyes of 100 subjects were included, with a mean age of 60.1 ± 15.7 years. Of these, 79 were of the right eye and 21 the left eye, 61 men and 39 women. It was found that the mean of the horizontal excavation obtained by the OCT was 0.91 ± 0.10, while that obtained by angiography was 0.79 ± 0.11 (p <0.01). It was concluded that there was no agreement between the evaluated methods to quantify the measurements of optic disc cup excavations. Measures obtained automatically by OCT RTVue of the OD were higher, but significantly correlated with measurements obtained manually by Digital Retinography. Poor agreement of the optic disc parameters between the two imaging devices was noted. / O objetivo deste estudo foi comparar as medidas lineares da escavação do disco óptico, obtidas com o OCT RTVue com as obtidas pela Retinografia Digital. Trata-se de um estudo transversal e retrospectivo, conduzido no Hospital VER - Excelência em Oftalmologia. Utilizou-se imagens de retinografia digital e exames de OCT obtidos pelo aparelho RTVue. Na retinografia colorida, foram obtidos os maiores diâmetros horizontal e vertical do disco óptico, a partir da borda interna do Anel de Elschnig através de paquímetro com graduação de 0,01 mm. No OCT, a delineação do nervo óptico foi obtida automaticamente e a partir dos resultados foi registrado o diâmetro horizontal e vertical da escavação. Foram incluídos 100 olhos de 100 indivíduos, com idade média de 60,1 ± 15,7 anos. Desses, 79 foram do olho direito e 21 do olho esquerdo, sendo 61 homens e 39 mulheres. Verificou-se que as médias das escavações horizontais obtidas com o OCT foram de 0,91 ± 0,10, enquanto que as obtidas pela retinografia foram 0,79 ± 0,11 (p < 0,01). Conclui-se que não houve concordância entre os métodos avaliados para quantificar as medidas das escavações do DO. As medidas obtidas automaticamente pelo OCT RTVue do DO foram maiores, porém correlacionadas com as medidas obtidas manualmente pela Retinografia Digital. Além disso, notou-se fraca concordância nos parâmetros do disco óptico entre os dois dispositivos de imagens.
3

Avaliação de polimorfismos nos genes IL1A, IL1B e TNFA em pacientes com glaucoma primário de ângulo aberto / Association of IL1A, IL1B and TNFA gene polymorphisms in primary open angle glaucoma patients

Oliveira, Mariana Borges, 1978- 25 August 2018 (has links)
Orientadores: Mônica Barbosa de Melo, José Paulo Cabral de Vasconcellos / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-25T15:53:03Z (GMT). No. of bitstreams: 1 Oliveira_MarianaBorges_M.pdf: 6901699 bytes, checksum: b84b4ac92949fdb082625b01ad6c66a1 (MD5) Previous issue date: 2014 / Resumo: O glaucoma engloba um grupo de doenças que têm como característica comum a atrofia progressiva do disco óptico com alteração correspondente de campo visual, decorrente da perda de células ganglionares da retina. O aumento da pressão intraocular (PIO) é o principal fator de risco para o desenvolvimento do glaucoma, mas tem sido sugerida a existência de outros aspectos relevantes, tais como alterações no metabolismo do óxido nítrico, na regulação do fluxo vascular, sinais de estresse oxidativo e alterações no sistema imunológico. O glaucoma primário de ângulo aberto (GPAA), a forma mais prevalente entre os glaucomas, está associado a uma série de fatores de risco para sua instalação e desenvolvimento, além da PIO. Os demais fatores de risco são: idade (relação direta), raça (mais frequente e grave em indivíduos da raça negra), miopia e história familiar de glaucoma. A maioria dos casos de GPAA apresenta um padrão complexo de hereditariedade, em que variantes de suscetibilidade contribuem para a gravidade da doença. O objetivo deste estudo do tipo caso-controle foi avaliar o papel de polimorfismos nos genes da interleucina alfa (IL1A), interleucina beta (IL1B) e fator de necrose tumoral alfa (TNFA) em relação à suscetibilidade ao GPAA. Após avaliação oftalmológica, foram recrutados 214 indivíduos não relacionados portadores de GPAA. A análise molecular foi realizada por meio de técnicas de PCR e sequenciamento direto. Neste estudo observou-se que o alelo C do polimorfismo -31 C/T, presente na região promotora do gene IL1B, confere risco para o glaucoma (p=0,002). Este alelo está contido em um "TATA" box, influenciando na transcrição deste gene. Existe um desequilíbrio de ligação entre os SNPs -31 C/T e -511 T/C do gene IL1B e este último também está associado a um risco aumentado para o glaucoma (p=0,006). Com relação aos demais SNPs estudados (+3954 C/T do gene IL1B, -889 C/T e +4845 G/T do gene IL1A e -238 G/A e -308 G/A do gene TNFA), não houve associação com o glaucoma. Este estudo sugere que há relação das variantes "C" do SNP -31 C/T e "T" do SNP -511 T/C do gene IL1B com a etiologia do GPAA em uma amostra da população brasileira / Abstract: Glaucoma comprises a group of diseases characterized by progressive atrophy of the optic disc and corresponding visual field loss, as consequence of retinal ganglion cells death. Augmented intraocular pressure (IOP) is the main risk factor for glaucoma development, but it has been suggested that there are other relevant aspects that may lead to neuronal and trabecular meshwork (TM) damage and contribute to the development of glaucoma, including alterations in nitric oxide metabolism, oxidative stress and vascular and immune system dysregulations. Primary open angle glaucoma (POAG), the most prevalent form of glaucoma, is associated with several risk factors to its initiation and progression besides IOP. The additional risk factors are: age (direct correlation), race (more frequent in black subjects), myopia and family history of glaucoma. The majority of POAG cases presents a complex pattern of heritability, in which susceptibility variants contribute to disease severity. The aim of this case-control study was to evaluate the role of single nucleotide polymorphisms (SNPs) in the interleukin alpha (IL1A), interleukin beta (IL1B) and tumor necrosis factor alpha (TNFA) genes in relation to POAG susceptibility. After ophthalmologic evaluation, 214 unrelated subjects with POAG were recruited. The molecular analysis was performed by PCR and direct sequencing techniques. In this study it was observed that the C allele of the -31 C/T promoter polymorphism of the IL1B gene confers risk for glaucoma (p=0.002). This allele disrupts a "TATA" box, influencing the transcription of the IL1B gene. There is linkage disequilibrium between the -31 C/T e -511 T/C SNPs, and the latter is also associated with an increased risk for glaucoma (p=0.006). Regarding the others studied SNPs (+3954 C/T of the IL1B gene, -889 C/T and +4845 G/T of the IL1A gene and -238 G/A and -308 G/A of the TNFA gene), there is no association with glaucoma. This study suggests the relationship of the "C" variant of -31C/T and "T" variant of -511T/C of IL1B gene with POAG etiology in a sample of the Brazilian population / Mestrado / Oftalmologia / Mestra em Ciências Médicas
4

Comparação de métodos de imagem do disco óptico e da camada de fibras nervosas da retina para o diagnóstico do glaucoma / Comparison of optic disc and retinal nerve fiber layer imaging methods for glaucoma diagnosis

Medeiros, Felipe de Araujo Andrade 02 June 2005 (has links)
Alterações no aspecto do disco óptico e da camada de fibras nervosas da retina (CFN) freqüentemente precedem o aparecimento de defeitos de campo visual no glaucoma, o que faz com que a avaliação destas estruturas seja essencial para o diagnóstico precoce e prevenção da perda visual nesta doença. A polarimetria de varredura a laser (GDx VCC), a oftalmoscopia confocal de varredura a laser (HRT II [Heidelberg Retina Tomograph]) e a tomografia de coerência óptica (Stratus OCT) são tecnologias que permitem a avaliação objetiva e quantitativa do disco óptico e da CFN. No presente estudo, estas tecnologias foram comparadas em sua habilidade para diferenciar pacientes glaucomatosos de indivíduos normais. Pacientes com glaucoma foram selecionados com base na presença de defeitos reprodutíveis de campo visual na perimetria acromática automatizada (glaucoma perimétrico), ou com base na evidência documentada de progressão do dano glaucomatoso ao disco óptico, sem presença de defeitos de campo visual (glaucoma pré-perimétrico). Indivíduos normais apresentaram campos visuais e exame clínico dentro da normalidade. Todos os indivíduos foram submetidos a exames com o GDx VCC, HRT II, Stratus OCT e campo visual dentro de um período de três meses. Diversas medidas foram utilizadas para avaliação da acurácia diagnóstica, incluindo áreas sob as curvas receiver operating characteristic (AROC), sensibilidades para especificidades fixas, e razões de probabilidade. Modelos estatísticos foram utilizados para avaliação da influência da severidade do glaucoma e tamanho do disco óptico na performance diagnóstica dos diferentes instrumentos. Um olho de cada indivíduo foi utilizado para análise. Dos 258 sujeitos inicialmente avaliados, 33 (13%) foram posteriormente excluídos por apresentarem imagens de baixa qualidade em pelo menos um dos aparelhos, restando 225 indivíduos (133 glaucomatosos e 92 normais) para análise. Na comparação entre os parâmetros de cada instrumento com maiores valores de AROC, o parâmetro do GDx VCC, Nerve Fiber Indicator (NFI; AROC = 0,91), e o parâmetro do Stratus OCT, Espessura Média (AROC = 0,90), apresentaram áreas sob as curvas ROC significativamente superiores à do parâmetro do HRT II, função discriminante de Bathija (AROC = 0,84). A severidade do defeito de campo visual exerceu influência significativa sob a acurácia diagnóstica dos três instrumentos, com melhora no poder diagnóstico em casos mais avançados da doença. Para o GDx VCC e Stratus OCT, o aumento no tamanho do disco óptico foi associado à diminuição na sensibilidade para detecção do glaucoma; enquanto que, para o HRT II, diminuição no tamanho do disco óptico foi associada à diminuição na sensibilidade. Razões de probabilidade para resultados anormais nas xxv classificações finais de cada instrumento foram associadas a grandes efeitos de mudança na probabilidade pós-teste em relação à probabilidade préteste, sugerindo que o encontro de um resultado anormal em qualquer um destes testes, durante a avaliação de um paciente com suspeita de glaucoma, tem impacto significativo em aumentar a probabilidade de que a doença esteja presente. Além disso, os resultados obtidos na avaliação de pacientes com glaucoma pré-perimétrico sugerem que todos os três instrumentos sejam capazes de detectar alterações estruturais precoces no glaucoma, antes do aparecimento de defeitos de campo visual na perimetria acromática / Changes in the structural appearance of the optic nerve head (ONH) and retinal nerve fiber layer (RNFL) have been reported to precede the development of visual field loss in glaucoma. Detection of ONH and RNFL damage is therefore crucial for early diagnosis of glaucoma and prevention of functional loss from the disease. Scanning laser polarimetry (GDx VCC), confocal scanning laser ophthalmoscopy (HRT II [Heidelberg Retina Tomograph]) and optical coherence tomography (Stratus OCT) are different technologies capable of providing objective and quantitative information related to these structures. The purpose of the present study was to compare, in a single population, the diagnostic abilities of these technologies in the discrimination of glaucomatous patients from healthy subjects. Glaucoma patients were selected based on the presence of repeatable visual field defects, as identified by standard automated perimetry (perimetric glaucoma), or documented evidence of progressive damage to the optic disc, in the absence of detectable visual field loss (preperimetric glaucoma). Normal subjects had normal visual fields and normal clinical examination. All subjects underwent imaging with the GDx VCC, HRT II and Stratus OCT within a 3-month period. Several measures were used for evaluation of diagnostic accuracy, including the area under the receiver operating characteristic curve (AROC), sensitivities at fixed specifities, and likelihood ratios. Statistical models were used to evaluate the influence of glaucoma severity and optic disc size on the diagnostic performance of the different instruments. One eye of each individual was randomly selected for statistical analysis. From an initial group of 258 eligible subjects, 33 (13%) had images of unacceptable quality, leaving 133 glaucoma patients and 92 healthy subjects for further analysis. In the comparison of the parameters with highest values of AROC from each instrument, the GDx VCC Nerve Fiber Indicator (AROC = 0.91) and the Stratus OCT Average Thickness (AROC = 0.90) perfomed significanlty better than the HRT II Bathija discriminant function (AROC = 0.84). For all instruments, the diagnostic accuracy increased with increasing severity of visual field defects. For the GDx VCC and Stratus OCT parameters, an increase in the size of the optic disc was related to a decrease in the sensitivity for glaucoma detection. An opposite effect was observed with the HRT II: a decrease in the size of the optic disc was related to a decrease in the sensitivity for glaucoma diagnosis. Abnormal results for each of the instruments were associated with strong positive likelihood ratios, indicating a large change from prestest to posttest probability of glaucoma. These results suggest that the finding of an abnormal result in any of these tests, when assessing a patient suspect of having glaucoma, would substantially raise the probability of disease. Results of the evaluation of patients with preperimetric glaucoma also suggest that all three instruments are able to detect early glaucomatous structural damage in the absence of visual field loss
5

Valor preditivo da topografia de disco óptico para o desenvolvimento de glaucoma / Predictive value of optic disc topography for the development of glaucoma

Alencar, Luciana Pereira Malta de 18 July 2011 (has links)
Objetivos: Analisar o potencial da oftalmoscopia confocal de varredura a laser, através do Heidelberg Retina Tomograph (HRT), para predizer o risco de progressão em pacientes com suspeita de glaucoma. Comparar os resultados obtidos com o índice de probabilidade de glaucoma (GPS) do HRT aos resultados da análise de regressão de Moorfields (ARM), dos parâmetros morfométricos e da avaliação das fotografias estereoscópicas. Métodos: Uma coorte foi selecionada com 223 pacientes com suspeita de glaucoma, que foram seguidos por um período médio de 64,9 ± 37,3 meses. A suspeita de glaucoma baseou-se na aparência do disco óptico e/ou na pressão intraocular elevada (> 21 mmHg). Todos os participantes apresentavam dois exames de campo visual normais ao entrar no estudo. Conceituou-se progressão como o desenvolvimento de um defeito confirmado de campo visual ou deterioração do disco óptico na avaliação seriada das estereofotografias. A associação entre os resultados do HRT na época do início do acompanhamento e a progressão para glaucoma foi investigada através de modelos de regressão do tipo Cox. Usou-se o C-index para a comparação entre os modelos com os diversos parâmetros do HRT, isolados ou ajustados para os outros já conhecidos fatores de risco para progressão (idade, espessura corneana, pressão intraocular e pattern standard deviation PSD). Resultados: No período do estudo, 46 pacientes (21%) apresentaram progressão. Na análise multivariada, o GPS, a ARM e diversos parâmetros morfométricos foram preditivos para progressão, assim como a avaliação subjetiva das estereofotografias. Cada GPS 0,1 maior foi associado com um aumento de 23% no risco de progressão (C-index de 0,69). Os resultados anormais nas classificações finais do GPS e da ARM foram associados a aumentos de 3 e 2 vezes no risco de progressão, respectivamente (C-indexes de 0,70 e 0,68, respectivamente). O parâmetro com o melhor C-index foi a área seccional tranversa da camada de fibras nervosas (0,72). Uma área 0,3 mm2 menor foi associada a um risco 62% maior de progressão. A comparação do valor preditivo entre os modelos com o GPS e com a avaliação subjetiva das estereofotografias foi similar (C-indexes de 0,69 e 0,68, respectivamente). Conclusão: Nesse estudo observamos que as análises objetivas do disco óptico e da região peripapilar obtidas com o HRT contribuíram na avaliação do risco de progressão em pacientes com suspeita de glaucoma. O GPS mostrou-se tão eficaz quanto os parâmetros morfométricos e a análise de regressão de Moorfields, e a comparação do desempenho dos modelos contendo a avaliação subjetiva das estereofotografias e aqueles contendo a avaliação objetiva pelo GPS não mostrou diferenças significativas / Purpose: To evaluate the ability of baseline confocal scanning laser ophthalmoscopy, using the Heidelberg Retina Tomograph (HRT), in predicting the development of progression in patients suspected of having glaucoma. In addition, the study also aimed to compare the predictive abilities of the glaucoma probability score (GPS) with those of the Moorfields regression analysis (MRA) and stereometric parameters, and to compare the performance of the HRT with that of subjective evaluation of optic disc stereophotographs. Methods: This longitudinal study included a cohort of 223 eyes suspected of having glaucoma, which were followed for an average of 64.9 ± 37.3 months. Included suspects had a suspicious appearance of the optic disc and/or elevated intraocular pressure, but normal visual fields. Progression was defined as the development of either repeatable abnormal visual fields or glaucomatous structural deterioration in the appearance of the optic disc during the study period. The association between baseline HRT parameters and progression was investigated by Cox regression models. The comparison between models with HRT parameters, individually or combined with other known risk factors (age, central corneal thickness, pattern standard deviation and intraocular pressure), performed by comparing their C-indexes. Results: Forty-six (21%) eyes converted during the study period. In multivariable models, the GPS, the MRA, and the stereometric parameters were all predictive of progression. A GPS 0.1 larger was associated with an increase of 23% in the risk of progression (C-index of 0.69). Abnormal final classifications for the GPS or the MRA were associated with a three-fold and two-fold increase in the risk of progression, respectively (with C-indexes of 0.70 and 0.68, respectively). The parameter with the best C-index was the nerve fiber layer cross-sectional area (0.72). An area 0.3 mm2 smaller was associated with a 62% higher risk of an individual progress. The comparison between models with the HRT parameters and those with the subjective stereophotograph evaluation had similar results (C-indexes of 0.69 and 0.68, respectively). Conclusion: In this study, we were able to show that the objective structural assessment of the optic disc and peripapillary area obtained with the HRT was significantly predictive for progression in suspected individuals. The GPS was as predictive as the other HRT parameters, and no significant differences were observed between models with the GPS and those with the subjective assessment of the stereophotographs.
6

Comparação entre diversas técnicas de imagem para diagnóstico do glaucoma / Comparison of different imaging techniques to diagnose glaucoma

Vessani, Roberto Murad 20 March 2008 (has links)
O objetivo desse estudo foi comparar a habilidade da avaliação subjetiva do disco óptico e da camada de fibras nervosas (CFN) por oftalmologistas generalistas e por um glaucomatólogo com medidas objetivas pela tomografia de coerência óptica (Stratus OCT), oftalmoscopia confocal de varredura a laser (HRTIII), e a polarimetria de varredura a laser (GDxECC) para discriminar olhos glaucomatosos de olhos normais. 61 olhos glaucomatosos e 57 olhos normais de 118 indivíduos foram incluídos nesse estudo. Três oftalmologistas generalistas independentes e um glaucomatólogo avaliaram fotografias estereoscópicas do disco óptico. Curvas ROC (Receiver Operator Characteristic) foram construídas para cada técnica de imagem e a sensibilidade a uma especificidade fixa foi determinada. Comparações das áreas sob essas curvas (AROC) e a concordância (k) foram determinadas entre a graduação das fotografias estereoscópicas e o melhor parâmetro de cada exame de imagem computadorizado. O melhor parâmetro de cada técnica de imagem computadorizada (CFN temporal inferior do Stratus OCT = 0,92; área integrada vertical da topografia do disco óptico pelo Stratus OCT = 0,86; espessura macular do setor inferior externo fornecido pelo Stratus OCT = 0,82; NFI do GDxECC = 0,91; razão área E/D do HRT3 = 0,83) mostrou AROC maior do que a graduação das fotografias estereoscópicas por oftalmologistas generalistas (0,80) para separar olhos glaucomatosos de olhos normais. A graduação por glaucomatólogo forneceu AROC igual ou maior (0,92) do que o melhor parâmetro de exame computadorizado de imagem. A avaliação das fotografias estereoscópicas por glaucomatólogo mostrou melhor concordância com o melhor parâmetro de cada técnica de imagem quantitativa na classificação de olhos como glaucomatosos ou normais comparadas à avaliação de fotografias estereoscópicas por oftalmologistas generalistas. A combinação da avaliação subjetiva do disco óptico por oftalmologistas generalistas com parâmetros objetivos da CFN melhorou a identificação de olhos com glaucoma em uma proporção maior do que a combinação desses parâmetros objetivos com a avaliação do disco óptico por um glaucomatólogo (29,5% versus 19,7%, respectivamente). Os resultados sugerem que a habilidade diagnóstica de todos os exames de imagem computadorizados estudados mostrou melhor desempenho que a avaliação subjetiva do disco óptico por oftalmologistas generalistas, mas não por um glaucomatólogo. Medidas objetivas da CFN podem permitir um aperfeiçoamento na detecção de glaucoma quando combinados com a avaliação subjetiva do disco óptico por oftalmologistas generalistas ou por um glaucomatólogo. / The purpose of this study was to compare the ability of subjective assessment of optic nerve head and retinal nerve fiber layer by general ophthalmologists and by a glaucoma expert with objective measurements by optical coherence tomography (Stratus OCT, Carl Zeiss Meditec, Inc.), confocal scanning laser ophthalmoscope (HRT III; Heidelberg Engineering, Heidelberg, Germany), and scanning laser polarimetry (GDx ECC; Carl Zeiss Meditec, Inc., Dublin, CA) in discriminating glaucomatous and normal eyes. 61 glaucomatous and 57 normal eyes of 118 subjects were included in the study. Three independent general ophthalmologists and one glaucoma expert evaluated ONH stereophotographs. Receiver operating characteristic curves were constructed for each imaging technique and sensitivity at fixed specificity was estimated. Comparisons of areas under these curves (aROC) and agreement (k) were determined between stereophoto grading and best parameter from each technique. Best parameter from each technique showed larger aROC (StratusOCT RNFL = 0.92; StratusOCT ONH vertical integrated area = 0.86; StratusOCT macular thickness = 0.82; GDxECC = 0.91; HRT3 global cup-to-disc area ratio = 0.83) compared to stereophotograph grading by general ophthalmologists (0.80) in separating glaucomatous and normal eyes. Glaucoma expert stereophoto grading provided equal or larger aROC (0.92) than best parameter of each computerized imaging device. Stereophoto evaluated by a glaucoma expert showed better agreement with best parameter of each quantitative imaging technique in classifying eyes either as glaucomatous or normal compared to stereophoto grading by general ophthalmologists. The combination of subjective assessment of the optic disc by general ophthalmologists with RNFL objective parameters improved identification of glaucoma patients in a larger proportion than the combination of these objective parameters with subjective assessment of the optic disc by a glaucoma expert (29.5% versus 19.7%, respectively). The results suggests that the diagnostic ability of all imaging techniques showed better performance than subjective assessment of the ONH by general ophthalmologists, but not by a glaucoma expert. Objective RNFL measurements may provide improvement in glaucoma detection when combined with subjective assessment of the optic disc by general ophthalmologists or by a glaucoma expert.
7

Comparação de métodos de imagem do disco óptico e da camada de fibras nervosas da retina para o diagnóstico do glaucoma / Comparison of optic disc and retinal nerve fiber layer imaging methods for glaucoma diagnosis

Felipe de Araujo Andrade Medeiros 02 June 2005 (has links)
Alterações no aspecto do disco óptico e da camada de fibras nervosas da retina (CFN) freqüentemente precedem o aparecimento de defeitos de campo visual no glaucoma, o que faz com que a avaliação destas estruturas seja essencial para o diagnóstico precoce e prevenção da perda visual nesta doença. A polarimetria de varredura a laser (GDx VCC), a oftalmoscopia confocal de varredura a laser (HRT II [Heidelberg Retina Tomograph]) e a tomografia de coerência óptica (Stratus OCT) são tecnologias que permitem a avaliação objetiva e quantitativa do disco óptico e da CFN. No presente estudo, estas tecnologias foram comparadas em sua habilidade para diferenciar pacientes glaucomatosos de indivíduos normais. Pacientes com glaucoma foram selecionados com base na presença de defeitos reprodutíveis de campo visual na perimetria acromática automatizada (glaucoma perimétrico), ou com base na evidência documentada de progressão do dano glaucomatoso ao disco óptico, sem presença de defeitos de campo visual (glaucoma pré-perimétrico). Indivíduos normais apresentaram campos visuais e exame clínico dentro da normalidade. Todos os indivíduos foram submetidos a exames com o GDx VCC, HRT II, Stratus OCT e campo visual dentro de um período de três meses. Diversas medidas foram utilizadas para avaliação da acurácia diagnóstica, incluindo áreas sob as curvas receiver operating characteristic (AROC), sensibilidades para especificidades fixas, e razões de probabilidade. Modelos estatísticos foram utilizados para avaliação da influência da severidade do glaucoma e tamanho do disco óptico na performance diagnóstica dos diferentes instrumentos. Um olho de cada indivíduo foi utilizado para análise. Dos 258 sujeitos inicialmente avaliados, 33 (13%) foram posteriormente excluídos por apresentarem imagens de baixa qualidade em pelo menos um dos aparelhos, restando 225 indivíduos (133 glaucomatosos e 92 normais) para análise. Na comparação entre os parâmetros de cada instrumento com maiores valores de AROC, o parâmetro do GDx VCC, Nerve Fiber Indicator (NFI; AROC = 0,91), e o parâmetro do Stratus OCT, Espessura Média (AROC = 0,90), apresentaram áreas sob as curvas ROC significativamente superiores à do parâmetro do HRT II, função discriminante de Bathija (AROC = 0,84). A severidade do defeito de campo visual exerceu influência significativa sob a acurácia diagnóstica dos três instrumentos, com melhora no poder diagnóstico em casos mais avançados da doença. Para o GDx VCC e Stratus OCT, o aumento no tamanho do disco óptico foi associado à diminuição na sensibilidade para detecção do glaucoma; enquanto que, para o HRT II, diminuição no tamanho do disco óptico foi associada à diminuição na sensibilidade. Razões de probabilidade para resultados anormais nas xxv classificações finais de cada instrumento foram associadas a grandes efeitos de mudança na probabilidade pós-teste em relação à probabilidade préteste, sugerindo que o encontro de um resultado anormal em qualquer um destes testes, durante a avaliação de um paciente com suspeita de glaucoma, tem impacto significativo em aumentar a probabilidade de que a doença esteja presente. Além disso, os resultados obtidos na avaliação de pacientes com glaucoma pré-perimétrico sugerem que todos os três instrumentos sejam capazes de detectar alterações estruturais precoces no glaucoma, antes do aparecimento de defeitos de campo visual na perimetria acromática / Changes in the structural appearance of the optic nerve head (ONH) and retinal nerve fiber layer (RNFL) have been reported to precede the development of visual field loss in glaucoma. Detection of ONH and RNFL damage is therefore crucial for early diagnosis of glaucoma and prevention of functional loss from the disease. Scanning laser polarimetry (GDx VCC), confocal scanning laser ophthalmoscopy (HRT II [Heidelberg Retina Tomograph]) and optical coherence tomography (Stratus OCT) are different technologies capable of providing objective and quantitative information related to these structures. The purpose of the present study was to compare, in a single population, the diagnostic abilities of these technologies in the discrimination of glaucomatous patients from healthy subjects. Glaucoma patients were selected based on the presence of repeatable visual field defects, as identified by standard automated perimetry (perimetric glaucoma), or documented evidence of progressive damage to the optic disc, in the absence of detectable visual field loss (preperimetric glaucoma). Normal subjects had normal visual fields and normal clinical examination. All subjects underwent imaging with the GDx VCC, HRT II and Stratus OCT within a 3-month period. Several measures were used for evaluation of diagnostic accuracy, including the area under the receiver operating characteristic curve (AROC), sensitivities at fixed specifities, and likelihood ratios. Statistical models were used to evaluate the influence of glaucoma severity and optic disc size on the diagnostic performance of the different instruments. One eye of each individual was randomly selected for statistical analysis. From an initial group of 258 eligible subjects, 33 (13%) had images of unacceptable quality, leaving 133 glaucoma patients and 92 healthy subjects for further analysis. In the comparison of the parameters with highest values of AROC from each instrument, the GDx VCC Nerve Fiber Indicator (AROC = 0.91) and the Stratus OCT Average Thickness (AROC = 0.90) perfomed significanlty better than the HRT II Bathija discriminant function (AROC = 0.84). For all instruments, the diagnostic accuracy increased with increasing severity of visual field defects. For the GDx VCC and Stratus OCT parameters, an increase in the size of the optic disc was related to a decrease in the sensitivity for glaucoma detection. An opposite effect was observed with the HRT II: a decrease in the size of the optic disc was related to a decrease in the sensitivity for glaucoma diagnosis. Abnormal results for each of the instruments were associated with strong positive likelihood ratios, indicating a large change from prestest to posttest probability of glaucoma. These results suggest that the finding of an abnormal result in any of these tests, when assessing a patient suspect of having glaucoma, would substantially raise the probability of disease. Results of the evaluation of patients with preperimetric glaucoma also suggest that all three instruments are able to detect early glaucomatous structural damage in the absence of visual field loss
8

Valor preditivo da topografia de disco óptico para o desenvolvimento de glaucoma / Predictive value of optic disc topography for the development of glaucoma

Luciana Pereira Malta de Alencar 18 July 2011 (has links)
Objetivos: Analisar o potencial da oftalmoscopia confocal de varredura a laser, através do Heidelberg Retina Tomograph (HRT), para predizer o risco de progressão em pacientes com suspeita de glaucoma. Comparar os resultados obtidos com o índice de probabilidade de glaucoma (GPS) do HRT aos resultados da análise de regressão de Moorfields (ARM), dos parâmetros morfométricos e da avaliação das fotografias estereoscópicas. Métodos: Uma coorte foi selecionada com 223 pacientes com suspeita de glaucoma, que foram seguidos por um período médio de 64,9 ± 37,3 meses. A suspeita de glaucoma baseou-se na aparência do disco óptico e/ou na pressão intraocular elevada (> 21 mmHg). Todos os participantes apresentavam dois exames de campo visual normais ao entrar no estudo. Conceituou-se progressão como o desenvolvimento de um defeito confirmado de campo visual ou deterioração do disco óptico na avaliação seriada das estereofotografias. A associação entre os resultados do HRT na época do início do acompanhamento e a progressão para glaucoma foi investigada através de modelos de regressão do tipo Cox. Usou-se o C-index para a comparação entre os modelos com os diversos parâmetros do HRT, isolados ou ajustados para os outros já conhecidos fatores de risco para progressão (idade, espessura corneana, pressão intraocular e pattern standard deviation PSD). Resultados: No período do estudo, 46 pacientes (21%) apresentaram progressão. Na análise multivariada, o GPS, a ARM e diversos parâmetros morfométricos foram preditivos para progressão, assim como a avaliação subjetiva das estereofotografias. Cada GPS 0,1 maior foi associado com um aumento de 23% no risco de progressão (C-index de 0,69). Os resultados anormais nas classificações finais do GPS e da ARM foram associados a aumentos de 3 e 2 vezes no risco de progressão, respectivamente (C-indexes de 0,70 e 0,68, respectivamente). O parâmetro com o melhor C-index foi a área seccional tranversa da camada de fibras nervosas (0,72). Uma área 0,3 mm2 menor foi associada a um risco 62% maior de progressão. A comparação do valor preditivo entre os modelos com o GPS e com a avaliação subjetiva das estereofotografias foi similar (C-indexes de 0,69 e 0,68, respectivamente). Conclusão: Nesse estudo observamos que as análises objetivas do disco óptico e da região peripapilar obtidas com o HRT contribuíram na avaliação do risco de progressão em pacientes com suspeita de glaucoma. O GPS mostrou-se tão eficaz quanto os parâmetros morfométricos e a análise de regressão de Moorfields, e a comparação do desempenho dos modelos contendo a avaliação subjetiva das estereofotografias e aqueles contendo a avaliação objetiva pelo GPS não mostrou diferenças significativas / Purpose: To evaluate the ability of baseline confocal scanning laser ophthalmoscopy, using the Heidelberg Retina Tomograph (HRT), in predicting the development of progression in patients suspected of having glaucoma. In addition, the study also aimed to compare the predictive abilities of the glaucoma probability score (GPS) with those of the Moorfields regression analysis (MRA) and stereometric parameters, and to compare the performance of the HRT with that of subjective evaluation of optic disc stereophotographs. Methods: This longitudinal study included a cohort of 223 eyes suspected of having glaucoma, which were followed for an average of 64.9 ± 37.3 months. Included suspects had a suspicious appearance of the optic disc and/or elevated intraocular pressure, but normal visual fields. Progression was defined as the development of either repeatable abnormal visual fields or glaucomatous structural deterioration in the appearance of the optic disc during the study period. The association between baseline HRT parameters and progression was investigated by Cox regression models. The comparison between models with HRT parameters, individually or combined with other known risk factors (age, central corneal thickness, pattern standard deviation and intraocular pressure), performed by comparing their C-indexes. Results: Forty-six (21%) eyes converted during the study period. In multivariable models, the GPS, the MRA, and the stereometric parameters were all predictive of progression. A GPS 0.1 larger was associated with an increase of 23% in the risk of progression (C-index of 0.69). Abnormal final classifications for the GPS or the MRA were associated with a three-fold and two-fold increase in the risk of progression, respectively (with C-indexes of 0.70 and 0.68, respectively). The parameter with the best C-index was the nerve fiber layer cross-sectional area (0.72). An area 0.3 mm2 smaller was associated with a 62% higher risk of an individual progress. The comparison between models with the HRT parameters and those with the subjective stereophotograph evaluation had similar results (C-indexes of 0.69 and 0.68, respectively). Conclusion: In this study, we were able to show that the objective structural assessment of the optic disc and peripapillary area obtained with the HRT was significantly predictive for progression in suspected individuals. The GPS was as predictive as the other HRT parameters, and no significant differences were observed between models with the GPS and those with the subjective assessment of the stereophotographs.
9

Comparação entre diversas técnicas de imagem para diagnóstico do glaucoma / Comparison of different imaging techniques to diagnose glaucoma

Roberto Murad Vessani 20 March 2008 (has links)
O objetivo desse estudo foi comparar a habilidade da avaliação subjetiva do disco óptico e da camada de fibras nervosas (CFN) por oftalmologistas generalistas e por um glaucomatólogo com medidas objetivas pela tomografia de coerência óptica (Stratus OCT), oftalmoscopia confocal de varredura a laser (HRTIII), e a polarimetria de varredura a laser (GDxECC) para discriminar olhos glaucomatosos de olhos normais. 61 olhos glaucomatosos e 57 olhos normais de 118 indivíduos foram incluídos nesse estudo. Três oftalmologistas generalistas independentes e um glaucomatólogo avaliaram fotografias estereoscópicas do disco óptico. Curvas ROC (Receiver Operator Characteristic) foram construídas para cada técnica de imagem e a sensibilidade a uma especificidade fixa foi determinada. Comparações das áreas sob essas curvas (AROC) e a concordância (k) foram determinadas entre a graduação das fotografias estereoscópicas e o melhor parâmetro de cada exame de imagem computadorizado. O melhor parâmetro de cada técnica de imagem computadorizada (CFN temporal inferior do Stratus OCT = 0,92; área integrada vertical da topografia do disco óptico pelo Stratus OCT = 0,86; espessura macular do setor inferior externo fornecido pelo Stratus OCT = 0,82; NFI do GDxECC = 0,91; razão área E/D do HRT3 = 0,83) mostrou AROC maior do que a graduação das fotografias estereoscópicas por oftalmologistas generalistas (0,80) para separar olhos glaucomatosos de olhos normais. A graduação por glaucomatólogo forneceu AROC igual ou maior (0,92) do que o melhor parâmetro de exame computadorizado de imagem. A avaliação das fotografias estereoscópicas por glaucomatólogo mostrou melhor concordância com o melhor parâmetro de cada técnica de imagem quantitativa na classificação de olhos como glaucomatosos ou normais comparadas à avaliação de fotografias estereoscópicas por oftalmologistas generalistas. A combinação da avaliação subjetiva do disco óptico por oftalmologistas generalistas com parâmetros objetivos da CFN melhorou a identificação de olhos com glaucoma em uma proporção maior do que a combinação desses parâmetros objetivos com a avaliação do disco óptico por um glaucomatólogo (29,5% versus 19,7%, respectivamente). Os resultados sugerem que a habilidade diagnóstica de todos os exames de imagem computadorizados estudados mostrou melhor desempenho que a avaliação subjetiva do disco óptico por oftalmologistas generalistas, mas não por um glaucomatólogo. Medidas objetivas da CFN podem permitir um aperfeiçoamento na detecção de glaucoma quando combinados com a avaliação subjetiva do disco óptico por oftalmologistas generalistas ou por um glaucomatólogo. / The purpose of this study was to compare the ability of subjective assessment of optic nerve head and retinal nerve fiber layer by general ophthalmologists and by a glaucoma expert with objective measurements by optical coherence tomography (Stratus OCT, Carl Zeiss Meditec, Inc.), confocal scanning laser ophthalmoscope (HRT III; Heidelberg Engineering, Heidelberg, Germany), and scanning laser polarimetry (GDx ECC; Carl Zeiss Meditec, Inc., Dublin, CA) in discriminating glaucomatous and normal eyes. 61 glaucomatous and 57 normal eyes of 118 subjects were included in the study. Three independent general ophthalmologists and one glaucoma expert evaluated ONH stereophotographs. Receiver operating characteristic curves were constructed for each imaging technique and sensitivity at fixed specificity was estimated. Comparisons of areas under these curves (aROC) and agreement (k) were determined between stereophoto grading and best parameter from each technique. Best parameter from each technique showed larger aROC (StratusOCT RNFL = 0.92; StratusOCT ONH vertical integrated area = 0.86; StratusOCT macular thickness = 0.82; GDxECC = 0.91; HRT3 global cup-to-disc area ratio = 0.83) compared to stereophotograph grading by general ophthalmologists (0.80) in separating glaucomatous and normal eyes. Glaucoma expert stereophoto grading provided equal or larger aROC (0.92) than best parameter of each computerized imaging device. Stereophoto evaluated by a glaucoma expert showed better agreement with best parameter of each quantitative imaging technique in classifying eyes either as glaucomatous or normal compared to stereophoto grading by general ophthalmologists. The combination of subjective assessment of the optic disc by general ophthalmologists with RNFL objective parameters improved identification of glaucoma patients in a larger proportion than the combination of these objective parameters with subjective assessment of the optic disc by a glaucoma expert (29.5% versus 19.7%, respectively). The results suggests that the diagnostic ability of all imaging techniques showed better performance than subjective assessment of the ONH by general ophthalmologists, but not by a glaucoma expert. Objective RNFL measurements may provide improvement in glaucoma detection when combined with subjective assessment of the optic disc by general ophthalmologists or by a glaucoma expert.
10

Tomografia de coerência óptica em olhos glaucomatosos com defeito assimétrico de hemicampo visual / Optical coherence tomography in glaucomatous eyes with assymetrical hemifield loss

Reis, Alexandre Soares Castro 08 November 2013 (has links)
Objetivo: Estudar as medidas de espessura da camada de fibras nervosas da retina(CFNR) peripapilar obtidas com as tomografias de coerência óptia (oCT) time domain (TD) e spectral domain (SD) em pacientes com perda assimétrica glaucomatosa de hemicampo visual, compará-las entre si e com aquelas de controles normais. Métodos: Trinta e seis pacientes com glaucoma primário de ângulo aberto e perda de campo visual em um hemicampo (afetado) e ausência de perda no hemicampo oposto (não afetado), e 36 controles pareados por idade tiveram o olho de estudo examinado com Stratus-OCT (Carl Zeiss Meditec Inc., Dublin, Califoprnia, USA) e o 3DOCT-1000 (Topcdon, Tokyo, Japan). As medidas de espessura da CFNR peripapilar e a classificação normativa fornecida pelos aparelhos foram registrados para análise. A média aritmética dos valores do mapa total deviation em cada hemicampo (mean deviation do hemicampo) foi calculada para cada indivíduo. \"Ìndices de assimetria\" para o campo visual e para a CFNR foram calculados como a razão entre o mean deviation dos hemicampos afetado e não-afetado, e como razão entre a espessura da CFNR das hemirretinas afetada e não-afetada, respectivamente. As variáveis contínuas foram comparadas usando os testes de Mann-Whitney, Kruskal-Wallis ou Wilcoxon, quando apropriados. As variáveis categóricas foram comparadas usando o teste qui-quadrado de Pearson. O coeficiente de correlação de Spearman foi usado para testar as correlações entre as medidas de espessura da CFNR fornecidas pelos OCTs. A presença de afinamento da CFNR foi estabelecida com base nos dados normativos fornecidos pelos softwares dos OCTs. As espessuras de CFNR fora do intervalo de previsão de 95% para a mesma faixa etária foram consideradas anormais. Resultados: As medidas de CFNR corespondentes a hemicampos não-afetados [média (DP) 87,0 (17,1) um e 84,3 (20,2) um, para TD e SD-OCT, respectivamente] foram menores do que as dos controles [média (DP) 119,0 (122,2)um e 117,0 (17,7) um, para TD e SD-OCT, respectivamente, P < 0,001, para ambos]. O banco de dados normativo classificou como alterado 42% e 67% das hemirretinas correspondentes a hemicampos não-acometidos com TD e SD-OCT, respectivamente (P = 0,01). As medidas da CFNR foram consistentemente mais espessas com TD comparadas com SD-OCT. Os índices de assimetria da CFNR em pacientes com glaucoma foram semelhantes entre TD [média (DP) 0,76 (0,17)] e SD-OCT [média (DP) 0,79 (0,12), P = 0,89] e significantemente maiores do que o índice de assimetria do campo visual [média (DP) 0,36 (0,20), P < 0,001]. Conclusões: Os hemicampos normais de pacientes com glaucoma apresentaram CFNR mais fina do que de olhos saudáveis. As medidas da CFNR foram mais espessas com TD do que com SD-OCT, o qual por sua vez detectou anormalidades na espessura da CFNR mais frequentemente do que o TD-OCT / Objective: To study the peripapillary retinal nerve fiber layer (RNFL) thickness measurements obtained with time domain (TD) and spectral domain (SD) optical coherence tomography (OCT) in glaucomatous patients with asymmetric visual hemifield loss, to compare themselves and with those obtained from normal controls. Methods : Thirty -six patients with primary open-angle glaucoma with visual primary open-angle glaucoma with visual field loss in one hemifield (affected ) and absence of loss in other (non-affected), and 36 age-matched healthy controls had the eye study imaged with Stratus-OCT (Carl Zeiss Meditec Inc., Dublin, Califoprnia, USA) and 3D OCT-1000 (Topcon , Tokyo, Japan). Peripapillary RNFL thickness measurements and normative classification were recorded for analysis. Total deviation values were averaged for each hemifield (hemifield mean deviation) for ecch subject. Visual field and RNFL \"asymmetry indexes\" were calculated as the ratio between the mean deviation of affected versus non-affected hemifields and RNFL thickness between as affected versus non-affected hemiretinas, respectively. Continuous variables were compared using the Mann-Whitney, Kruskal-Wallis or Wilcoxon tests, when appropriate. Categorical variables were compared using the Pearson\'s chi-square test. The Spearman\'s rank correlation coefficient was used to test correlations between RNFL thickness measurements provided by both OCTs . The presence of RNFL thinning was establised based on normative data provided by the OCT\'s software. The RNFL thicknesses outside the prediction interval of 95% for the same age group were considered abnormal. Results: The RNFL measurements in non-affected hemifields [mean (SD 87.0 (17.1) e 84.3(20.2) um, for TD and SD-OCT, respectively] were thinner than those of normal controls [mean (SD) 119.0 (12.2) um and 117.0 (17.7) um, for TD and SD-OCT, respectively, P < 0.001 for both ] . The OCT normative database classified 42 % and 67% of hemiretinas corresponding to non-affected hemifields as abnormal in TD and SD-OCT, respectively (P =0.01). The RNFL measurements were consistently thicker with TD compared with SD -OCT. The RNFL thickness asymetry index in patients with glaucoma was similar with TD [ mean (SD) 0.76 ( 0.17 ) ] and SD-OCT [ mean (SD)0.79(0.12), P = 0,89] and significantly greater than the visual field asymmetry index [ mean (SD ) 0.36 (0.20 ), P < 0.001]. Conclusions: Normal hemifields of glaucoma patients had thinner RNFL measurements than healthy eyes, as measured by TD and SD-OCT. The RNFL measurements were thicker with TD than SD-OCT, SD-OCT detected abnormal RNFL more often than TD-OCT

Page generated in 0.435 seconds