• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 15
  • Tagged with
  • 15
  • 15
  • 15
  • 13
  • 11
  • 11
  • 11
  • 11
  • 8
  • 8
  • 6
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação da potencialidade de eletrodos compósitos à base de grafite/poliuretana modificados com hexacianoferratos de Cu(II), Co(II) e Fe(III) para fins analíticos / Evaluation of the analytical potentialities fo composites electrodes based on graphite/polyurethane modified with hexacyanoferrates of Cu(II), Co(II) and Fe(III)

Vicentini, Fernando Campanhã 09 April 2009 (has links)
Eletrodos compósitos à base de grafite/poliuretana foram preparados contendo diferentes quantidades de hexacianoferratos de cobre(II), cobalto(II) e ferro(III). Os complexos foram preparados de acordo como procedimentos descritos na literatura e caracterizados por análise elementar, análise térmica e espectrometria na região do infra-vermelho. A análise térmica mostrou que há 10 moléculas de água de hidratação no hexacianoferrato de cobre(II), 11 no hexacianoferrato de cobalto(II) e 16 no hexacianoferrato de ferro(III). Após desidratação ocorre decomposição exotérmica violenta dos complexos. No caso do cobre a decomposição se dá com formação de CuO seguida da degradação do Fe(CN)3 com formação de Fe2O3. Para o hexacianoferrato de cobalto(II) e o hexacianoferrato de ferro(III) a mistura de Co3O4/Fe2O3 e o Fe2O3, respectivamente, se formaram após uma única etapa de decomposição. Apenas os eletrodos preparados com os complexos de cobalto e cobre apresentaram sinais voltamétricos, enquanto que o complexo de ferro não respondeu, provavelmente devido à sua baixa solubilidade em água. As condições de preparação dos eletrodos, tais como composição, ordem de adição de reagentes, pH, eletrólito suporte e intervalo de potenciais foram otimizadas. Um mecanismo para explicar a não estabilização do sinal voltamétrico, mesmo após ciclagem de potencial foi proposto com base na baixa solubilidade dos sais em água e a sua imobilização no eletrodo sólido a qual dificulta a formação do filme de hexacianoferrato na superfície. Finalmente um método analítico para a determinação de piridoxina, usando o eletrodo de grafite/poliuretana modificado com hexacianoferrato de cobre(II) foi proposto, com base na redução de sinal do complexo, na presença do analito. Neste caso foi observada uma resposta linear entre 1,08 x 10-6 a 1,07 x 10-5 mol L-1, com limite de detecção de 8,78 x 10-7 mol L-1 (3 x S/N) e o método foi aplicado na determinação de piridoxina em duas formulações comerciais. Coeficientes de recuperação entre 98-120% foram observados sem interferência dos componentes das formulações e sem necessidade de renovação da superfície do eletrodo. / Graphite-poliurethane solid composite electrodes were prepared containing different amounts of copper(II), cobalt(II) and iron(III) hexacianoferrates. The complexes were synthesized according to procedures previously described and characterized using elemental analysis, infrared spectrometry and the thermal analytical techniques: thermogravimetry/derivative thermogravimetry and differential thermal analysis. The thermal analysis revealed that there are 10 hydration water molecules in the copper(II) hexacianoferrate, 11 in the cobalt(II) and 16 in the iron(III) complexes. After dehydration, a strong exothermal degradation occurred in all cases. The copper complex decomposed in two steps with generation of CuO, followed by degradation of the Fe(CN)3 and formation of Fe2O3. The cobalt(II) and iron(III) hexacianoferrates decomposed in a single step with generation of Co3O4/Fe2O3 mixture and Fe2O3 as residues respectively. Only the electrodes prepared with copper and cobalt complexes presented voltammetric signals, while the iron complexes did not responded, probably due to its very low solubility in water. The conditions for the electrode preparation such as composition, order of addition of the components supporting electrolyte, pH and useful potential window were optimized. A mechanism to explain the non-stabilization of the voltammetric signal even after 200 cycles has been proposed on the basis of the complexes solubility in water as well as the immobilization of the complex in the solid electrode that turns difficult the formation of the hexacianoferrate film on the electrode surface. Finally, a graphite polyurethane electrode modified with the Cu(II) hexacianoferrate has been used in the voltammetric determination of pyridoxine, based on the diminution of the voltammetric signal of the modifier in the presence of the analyte. In this case a linear dynamic range of 1.08 x 10-6 to 1.07 x 10-5 mol L-1, with a detection limit of 8.78 x 10-7 mol L-1 (3 x S/N). The proposed electrode was used in the determination of pyridoxine in two solid pharmaceutical formulations with recoveries of 98 - 120% without interference of the other substances present in the formulation and no adsorption on the electrode surface.
2

Avaliação da potencialidade de eletrodos compósitos à base de grafite/poliuretana modificados com hexacianoferratos de Cu(II), Co(II) e Fe(III) para fins analíticos / Evaluation of the analytical potentialities fo composites electrodes based on graphite/polyurethane modified with hexacyanoferrates of Cu(II), Co(II) and Fe(III)

Fernando Campanhã Vicentini 09 April 2009 (has links)
Eletrodos compósitos à base de grafite/poliuretana foram preparados contendo diferentes quantidades de hexacianoferratos de cobre(II), cobalto(II) e ferro(III). Os complexos foram preparados de acordo como procedimentos descritos na literatura e caracterizados por análise elementar, análise térmica e espectrometria na região do infra-vermelho. A análise térmica mostrou que há 10 moléculas de água de hidratação no hexacianoferrato de cobre(II), 11 no hexacianoferrato de cobalto(II) e 16 no hexacianoferrato de ferro(III). Após desidratação ocorre decomposição exotérmica violenta dos complexos. No caso do cobre a decomposição se dá com formação de CuO seguida da degradação do Fe(CN)3 com formação de Fe2O3. Para o hexacianoferrato de cobalto(II) e o hexacianoferrato de ferro(III) a mistura de Co3O4/Fe2O3 e o Fe2O3, respectivamente, se formaram após uma única etapa de decomposição. Apenas os eletrodos preparados com os complexos de cobalto e cobre apresentaram sinais voltamétricos, enquanto que o complexo de ferro não respondeu, provavelmente devido à sua baixa solubilidade em água. As condições de preparação dos eletrodos, tais como composição, ordem de adição de reagentes, pH, eletrólito suporte e intervalo de potenciais foram otimizadas. Um mecanismo para explicar a não estabilização do sinal voltamétrico, mesmo após ciclagem de potencial foi proposto com base na baixa solubilidade dos sais em água e a sua imobilização no eletrodo sólido a qual dificulta a formação do filme de hexacianoferrato na superfície. Finalmente um método analítico para a determinação de piridoxina, usando o eletrodo de grafite/poliuretana modificado com hexacianoferrato de cobre(II) foi proposto, com base na redução de sinal do complexo, na presença do analito. Neste caso foi observada uma resposta linear entre 1,08 x 10-6 a 1,07 x 10-5 mol L-1, com limite de detecção de 8,78 x 10-7 mol L-1 (3 x S/N) e o método foi aplicado na determinação de piridoxina em duas formulações comerciais. Coeficientes de recuperação entre 98-120% foram observados sem interferência dos componentes das formulações e sem necessidade de renovação da superfície do eletrodo. / Graphite-poliurethane solid composite electrodes were prepared containing different amounts of copper(II), cobalt(II) and iron(III) hexacianoferrates. The complexes were synthesized according to procedures previously described and characterized using elemental analysis, infrared spectrometry and the thermal analytical techniques: thermogravimetry/derivative thermogravimetry and differential thermal analysis. The thermal analysis revealed that there are 10 hydration water molecules in the copper(II) hexacianoferrate, 11 in the cobalt(II) and 16 in the iron(III) complexes. After dehydration, a strong exothermal degradation occurred in all cases. The copper complex decomposed in two steps with generation of CuO, followed by degradation of the Fe(CN)3 and formation of Fe2O3. The cobalt(II) and iron(III) hexacianoferrates decomposed in a single step with generation of Co3O4/Fe2O3 mixture and Fe2O3 as residues respectively. Only the electrodes prepared with copper and cobalt complexes presented voltammetric signals, while the iron complexes did not responded, probably due to its very low solubility in water. The conditions for the electrode preparation such as composition, order of addition of the components supporting electrolyte, pH and useful potential window were optimized. A mechanism to explain the non-stabilization of the voltammetric signal even after 200 cycles has been proposed on the basis of the complexes solubility in water as well as the immobilization of the complex in the solid electrode that turns difficult the formation of the hexacianoferrate film on the electrode surface. Finally, a graphite polyurethane electrode modified with the Cu(II) hexacianoferrate has been used in the voltammetric determination of pyridoxine, based on the diminution of the voltammetric signal of the modifier in the presence of the analyte. In this case a linear dynamic range of 1.08 x 10-6 to 1.07 x 10-5 mol L-1, with a detection limit of 8.78 x 10-7 mol L-1 (3 x S/N). The proposed electrode was used in the determination of pyridoxine in two solid pharmaceutical formulations with recoveries of 98 - 120% without interference of the other substances present in the formulation and no adsorption on the electrode surface.
3

Estudo voltamétrico e desenvolvimento de metodologia eletroanalítica para determinação do inseticida fipronil utilizando o eletrodo compósito de grafite-poliuretana / Voltammetric investigation and development of electroanalytical procedure for the determination of fipronil using the graphite-polyurethane composite electrode

Okumura, Fabiano 18 September 2009 (has links)
O comportamento eletroquímico do inseticida fipronil, 5-amino-[(2,6-dicloro)-4-trifluormetil-fenil]-4-trifluormetil-sulfinil-1H pirazol-3-carbonitrila, foi investigado pelas técnicas de voltametria cíclica, voltametria de onda quadrada, eletrólise a potencial controlado e voltametria de redissolução de onda quadrada utilizando o eletrodo compósito de grafite-poliuretana. O fipronil apresentou um comportamento de um sistema irreversível com potencial de pico de 0,95 V. O processo de transferência de carga apresentou um controle misto de difusão e adsorção de espécies na superfície do eletrodo. O pH 8,0 foi escolhido para o desenvolvimento de uma metodologia eletroanalítica para determinação do composto. Os estudos por eletrólise a potencial controlado mostraram que a oxidação do inseticida envolve a participação de um elétron. Na voltametria de onda quadrada, o melhor sinal de corrente foi obtido com os valores de freqüência de 100 s-1, amplitude de 50 mV e incremento de varredura de 2 mV. Os limites de detecção e de quantificação foram calculados pelo método da IUPAC e pelo método de extrapolação da curva analítica. A metodologia desenvolvida foi comparada com o método oficial de análise, a cromatografia líquida de alta eficiência com detecção de ultravioleta por meio do método de curvas de calibração por meio de adição externa de padrão e foi observada concordância entre os dois métodos no intervalo de concentração estudado. Nos estudos de pré-concentração, as melhores condições encontradas foram um potencial de acumulação de 0,5 V e tempo de acumulação de 120 s. Amostras de águas naturais, formulação veterinária e leite foram analisadas pelos procedimentos propostos. / The electrochemical behavior of the insecticide fipronil, 5-amine-[(2,6-dichloro)-4-trifluoromethyl-phenyl]-4-trifluoromethyl-sulfynil-1H pyrazole-3-carbonitrile, was investigated by cyclic voltammetry, square wave voltammetry, controlled potential electrolysis and square wave stripping voltammetry using the graphite-polyurethane composite electrode. The electrochemical behavior of fipronil is a typical irreversible system and a peak potential at 0.95 V was observed. The charge transference process is controlled by diffusion and adsorption of species at electrode surface. The pH value 8.0 was chosen in order to develop an electroanalytical methodology for the determination the compound. Controlled potential electrolysis studies showed that the fipronil oxidation involves the participation of one electron. Square wave voltammetry investigations showed that the best current intensity was obtained using the values of a frequency of 100 s-1, pulse amplitude of 50 mV and scan increment of 2 mV. The limits of detection and quantification were calculated the IUPAC equations and statistics equations. The developed methodology was compared to the official analysis method, high performance liquid chromatography with ultraviolet detection, using the calibration curves method. Both procedures are in agreement with the concentration-studied range. Stripping analysis studies were done in order to determine fipronil traces in natural water. The best conditions found were the accumulation potential of 0.5 V and accumulation time of 120 s. The electroanalytical methodology, based on the square wave voltammetry, was applied for the analysis of natural water samples, a commercial veterinary formulation and milk samples.
4

Estudo voltamétrico e desenvolvimento de metodologia eletroanalítica para determinação do inseticida fipronil utilizando o eletrodo compósito de grafite-poliuretana / Voltammetric investigation and development of electroanalytical procedure for the determination of fipronil using the graphite-polyurethane composite electrode

Fabiano Okumura 18 September 2009 (has links)
O comportamento eletroquímico do inseticida fipronil, 5-amino-[(2,6-dicloro)-4-trifluormetil-fenil]-4-trifluormetil-sulfinil-1H pirazol-3-carbonitrila, foi investigado pelas técnicas de voltametria cíclica, voltametria de onda quadrada, eletrólise a potencial controlado e voltametria de redissolução de onda quadrada utilizando o eletrodo compósito de grafite-poliuretana. O fipronil apresentou um comportamento de um sistema irreversível com potencial de pico de 0,95 V. O processo de transferência de carga apresentou um controle misto de difusão e adsorção de espécies na superfície do eletrodo. O pH 8,0 foi escolhido para o desenvolvimento de uma metodologia eletroanalítica para determinação do composto. Os estudos por eletrólise a potencial controlado mostraram que a oxidação do inseticida envolve a participação de um elétron. Na voltametria de onda quadrada, o melhor sinal de corrente foi obtido com os valores de freqüência de 100 s-1, amplitude de 50 mV e incremento de varredura de 2 mV. Os limites de detecção e de quantificação foram calculados pelo método da IUPAC e pelo método de extrapolação da curva analítica. A metodologia desenvolvida foi comparada com o método oficial de análise, a cromatografia líquida de alta eficiência com detecção de ultravioleta por meio do método de curvas de calibração por meio de adição externa de padrão e foi observada concordância entre os dois métodos no intervalo de concentração estudado. Nos estudos de pré-concentração, as melhores condições encontradas foram um potencial de acumulação de 0,5 V e tempo de acumulação de 120 s. Amostras de águas naturais, formulação veterinária e leite foram analisadas pelos procedimentos propostos. / The electrochemical behavior of the insecticide fipronil, 5-amine-[(2,6-dichloro)-4-trifluoromethyl-phenyl]-4-trifluoromethyl-sulfynil-1H pyrazole-3-carbonitrile, was investigated by cyclic voltammetry, square wave voltammetry, controlled potential electrolysis and square wave stripping voltammetry using the graphite-polyurethane composite electrode. The electrochemical behavior of fipronil is a typical irreversible system and a peak potential at 0.95 V was observed. The charge transference process is controlled by diffusion and adsorption of species at electrode surface. The pH value 8.0 was chosen in order to develop an electroanalytical methodology for the determination the compound. Controlled potential electrolysis studies showed that the fipronil oxidation involves the participation of one electron. Square wave voltammetry investigations showed that the best current intensity was obtained using the values of a frequency of 100 s-1, pulse amplitude of 50 mV and scan increment of 2 mV. The limits of detection and quantification were calculated the IUPAC equations and statistics equations. The developed methodology was compared to the official analysis method, high performance liquid chromatography with ultraviolet detection, using the calibration curves method. Both procedures are in agreement with the concentration-studied range. Stripping analysis studies were done in order to determine fipronil traces in natural water. The best conditions found were the accumulation potential of 0.5 V and accumulation time of 120 s. The electroanalytical methodology, based on the square wave voltammetry, was applied for the analysis of natural water samples, a commercial veterinary formulation and milk samples.
5

Estudos sobre o comportamento eletroquímico da N-nitrosodifenilamina e sua determinação em amostras de urina sintética / Studies about the electrochemical behavior of N-Nitrosodiphenylamine and its determination in synthetic urine samples

Martoni, Lucas Vinicius Leite 17 May 2019 (has links)
Na presente dissertação, o comportamento eletroquímico da nitrosamina aromática N-Nitrosodifenilamina (NDPhA) foi caracterizado em eletrodo de carbono vítreo (GCE) em meio aquoso através de técnicas eletroanalíticas e espectroscópicas. Para tal, propôs-se um mecanismo de oxidação em quatro etapas envolvendo quatro elétrons e quatro prótons, assim como de redução em três ou quatro etapas, dependendo do pH do meio, também envolvendo quatro elétrons e quatro prótons no total. Diferentes eletrodos de carbono (GCE e GPUE) foram comparados e caracterizados eletroquimicamente através de técnicas cronocoulométricas e voltamétricas, e microscopia de imagem (Microscopia Eletrônica de Varredura e Microscopia de Força Atômica) com objetivo de aplicá-los na quantificação de NDPhA em amostras de urina. Após otimização das condições experimentais, o GPUE demonstrou-se ser mais sensível que o GCE apresentando uma faixa linear de 2,5 a 17,5 &mu;mol L-1, com sensibilidade igual a 5,50 &mu;A L &mu;mol-1 cm-2, coeficiente de correlação igual a 0,9998 e limite de detecção igual a 0,27 /&mu;mol L-1, apresentando sensibilidade cinco vezes maior e limite de detecção calculado cerca de 20 vezes menor. O preparo do eletrodo e a resposta do mesmo se mostraram reprodutível ao longo do tempo. Ademais, o método desenvolvido foi aplicado em uma amostra de urina sintética, utilizando o método de adição e recuperação, e foi possível concluir que esse processo pode ser aplicado a essa amostra com 95% de confiança. / In the present dissertation, the electrochemical behaviour of the aromatic nitrosamine N-Nitrosodiphenylamine (NDPhA) on the Glassy Carbon Electrode (GCE) in aqueous medium was characterized through electroanalytical and spectroscopic techniques. A four-step oxidation mechanism was proposed involving four electrons and four protons, as well as a reduction in three or four steps, depending on the pH of the medium, also involving four electrons and four protons in total. Different carbon electrodes (GCE and GPUE) were compared and characterized electrochemically by chronocoulometry and voltammetric techniques, and image microscopy (Scanning Electron Microscopy and Atomic Force Microscopy) with the objective of applying them to the quantification of NDPhA in urine samples. After optimization of the experimental conditions, the GPUE presented to be more sensitive than the CGE with a linear range of 2.5 to 17.5 &mu;mol L-1, with sensitivity equal to <br /> 5.50 &mu;A L &mu;mol-1 cm-2, correlation coefficient equal to 0.9998 and detection limit equal to 0.27 / &mu;mol L-1, with sensitivity five times higher and detection limit calculated about 20 times lower. The preparation of the electrode and its response proved to be reproducible over time. In addition, the developed method was applied in a synthetic urine sample, using the addition and recovery method, and it was possible to conclude that this process can be applied to this sample with 95% confidence.
6

Determinação eletroanalítica dos herbicidas 2,4-D e metribuzin em amostras de solo utilizando um eletrodo compósito de grafite-poliuretana / Electroanalytical determination of the herbicides 2,4-D and metribuzin in soil samples using graphite-polyurethane composite electrode.

Andrade, Fernanda Ramos de 18 July 2008 (has links)
O presente trabalho apresenta um estudo eletroquímico da redução dos herbicidas 2,4-D e metribuzin bem como o desenvolvimento de metodologias analíticas para determinação destes compostos em amostras naturais. Os experimentos foram realizados sobre eletrodo compósito de grafite-poliuretana (GPU) utilizando a técnica de voltametria de onda quadrada (SWV). A técnica de Voltametria Cíclica (VC) foi utilizada para diagnosticar o grau de reversibilidade da reação de redução dos herbicidas assim como a natureza do transporte da material eletroativo para a superfície do eletrodo de GPU. Os eletrólitos suportes utilizados nos experimentos foram: tampão Britton-Robinson (BR) para o 2,4-D e água acidificada com H2SO4 0,1 mol L-1 para o metribuzin, ambos em pH 2. Os resultados indicaram que tanto o 2,4-D quanto para o metribuzin, apresentam um único pico de redução com características de processo irreversível controlado pela adsorção de reagente na superfície do eletrodo. Os parâmetros da técnica de SWV (freqüência, amplitude e incremento de varredura), bem como o tempo e potencial de acumulação foram otimizados para obtenção de maior sensibilidade analítica. Curvas analíticas dos dois herbicidas foram obtidas no intervalo de 1,5 a 12 &micro;mol L-1 para os dois herbicidas. Os limites de detecção (LD) e de quantificação (LQ) obtidos para o 2,4-D, foram de 17,6 &micro;g L-1 e 58,6 &micro;g L-1, respectivamente. Para o metribuzin, o LD foi de 1,67 &micro;g L-1 e o LQ 5,56 &micro;g L-1. A precisão das metodologias desenvolvidas foi avaliada por meio da repetibilidade e a reprodutibilidade e a exatidão determinada pelo erro relativo. Os testes de recuperação realizados pelo método de adição de padrão forneceram valores de 104 % para o 2,4-D e 102 % para o metribuzin. As metodologias eletroanalíticas desenvolvidas para determinação do 2,4-D e do metribuzin, foram aplicadas em um estudo para avaliação do tempo de percolação dos mesmos em dois solos com características distintas. Os resultados indicaram que os dois herbicidas apresentam alta mobilidade nos solos estudados, pois 24 horas após a aplicação já foi possível detectar a presença dos mesmos na solução do solo extraída. Para o 2,4-D, 7 dias após o início do experimento, foram encontrados apenas resíduos de herbicida, enquanto que para o metribuzin obteve-se concentrações próximas a 1 mg L-1, mesmo depois de 14 dias. Após 100 dias do início do experimento observou-se um maior acúmulo de 2,4-D no solo arenoso, que pode ter ocorrido devido ao teor mais elevado de MO do solo argiloso, que proporciona uma quantidade maior de microorganismos no solo e que podem degradar o 2,4-D. Já para o metribuzin pode-se observar que este fica adsorvido nas primeiras profundidades do solo argiloso, possivelmente pelas maiores quantidades de MO e CTC. O eletrodo de GPU com a técnica de SWV apresentou bons resultados no que diz respeito à sensibilidade e ao tempo de análise, sendo uma excelente alternativa ao eletrodo de mercúrio, usualmente utilizado em medidas eletroanalíticas do 2,4-D e metribuzin. Os resultados obtidos com amostras de solo e formulação comercial dos herbicidas são bastante coerentes, considerando a dinâmica da dissipação espacial e temporal dos herbicidas no perfil do solo. / This research presents an electrochemical study of the herbicides 2,4-D and metribuzin reductions and the development of analytical methodologies for the determination of such substances in natural samples. The experiments were done with a graphite-polyurethane composite electrode (GPU) using the square wave voltammetry (SWV). The cyclic voltammetry (CV) was used to evaluate the reversibility degree of the herbicides reductions and thus the transport nature of the electroactive material to the surface of the GPU electrode. The supporting electrolytes used in the experiments were Britton-Robinson (BR) buffer for the 2,4-D and acidified water with H2SO4 0,1 mol L-1 for the metribuzin, both at pH 2. Results indicated that the 2,4-D and metribuzin show one reduction peak reduction with irreversible process characteristics, which are controlled by the adsorption of the reagent in the electrode surface. The SWV technique parameters (frequency, amplitude and scanning increment) and the time and potential of accumulation were optimized in order to obtain the highest analytic sensibility. Analytical curves were obtained from 0,33 mg L-1 to 2,62 mg L-1 for 2,4-D and 0,32 mg L-1 to 4,72 mg L-1 for metribuzin. The detection (LD) and quantification limits (LQ) obtained for 2,4-D were 17,6 &micro;g L-1 and 58,6 &micro;g L-1, respectively. For metribuzin, the LD was 1,67 &micro;g L-1 and the LQ was 5,56 &micro;g L-1. The precision of the developed methodologies was evaluated though its repeatability and reproductibility, besides the accuracy were determined by the relative error. Recovery experiments done by the standard addition method, provided values of 104 % for the 2,4-D and 102 % for the metribuzin. The electroanalytical methodologies developed for the determination of these herbicides were applied in two different soils with distinct characteristics, one sandy and other clayed soil. Results indicate that the herbicides present high mobility in the studied soils and 24 hours after its application it was possible to detect the presence of the herbicides in the soil solution extract. For the 2,4- D, seven days after the beginning of the experiment it was measured only residues, but for the metribuzin it is possible to measure concentrations around 1 mg L-1, even after fourteen days. After 100 days it was observed the highest accumulation of the 2,4-D in the sandy soil, that can be explained by the highest content of OM in the clay soil, which provides a higher content of 2,4-D degrading microorganisms. The herbicide metribuzin was adsorbed in the first layers of the clay soil, possibly due to the higher CTC and OM amounts in the soil profile. The GPU electrode with the SWV technique presented very good results when considered the sensibility and time analyses, being an excellent alternative for the mercury electrode usually used in the electroanalytical measurements of the 2,4-D and metribuzin. The obtained results with soil samples and commercial formulation of the herbicides are very consistent, considering the spatial and temporal dissipation dynamics of the herbicides in the soil.
7

Determinação de tetraciclina utilizando eletrodos compósitos grafite-poliuretana modificados com polímeros metacrilatos com impressão molecular / Determination of tetracycline using graphite-polyuretane composites electrodes modified with methacrylate molecularly imprinted polymers

José Eduardo dos Santos Clarindo 27 September 2017 (has links)
Neste trabalho propôs-se desenvolver eletrodos compósitos à base de grafite-poliuretana modificados com polímeros metacrilatos com impressão molecular (MIP-TC), visando a determinação do antibiótico tetraciclina em formulações farmacêuticas e urina sintética. O trabalho também visou contribuir no desenvolvimento de um sensor com melhor desempenho no que diz respeito à sensibilidade e seletividade do eletrodo compósito modificado, na quantificação do analito/molécula molde em matrizes complexas. Técnicas eletroanalíticas, tais como voltametria cíclica (CV) e voltametria de pulso diferencial (DPV) foram utilizadas para avaliar a resposta em termos de sensibilidade e seletividade do eletrodo compósito na detecção da tetraciclina (TC), proposto neste trabalho. A otimização dos parâmetros, tais como composição do MIP (5,0 %, m/m), amplitude de pulso (50 mV), velocidade de varredura (10 mV s-1), tempo (300 s) e potencial de acumulação [(+ 0,7 V (vs. SCE)] e faixa granulométrica do MIP (150 a 250 &mu;m), usando voltametria de redissolução anódica por pulso diferencial foi realizada para maximizar a determinação da tetraciclina em tampão fosfato 0,10 mol L -1 (pH 2,5), permitindo obter limites de detecção de 0,555 &mu;mol L-1, 2,70 &mu;mol L-1 e 4,71 &mu;mol L-1, respectivamente, para o EGPU-MIP-TC, EGPU e EGPU-NIP, sem necessidade de renovação da superfície do eletrodo entre as sucessivas medidas. Regiões lineares entre 4,0 e 60,0 &mu;mol L-1, 8,0 e 60,0 &mu;mol L-1 e 20,0 e 100,0 &mu;mol L-1/sup> foram observadas, respectivamente, para o EGPU-MIP-TC, EGPU e EGPU-NIP, para o pico anódico em + 0,9 V (vs. SCE). Os EGPU também foram testados quanto à seletividade frente à possíveis interferentes, sendo utilizados clortetraciclina (CTC) e oxitetraciclina (OTC) para os testes de interferência. Em todos os casos, a interferência do EGPU-MIP-TC foi menor do que a obtida com o EGPU-NIP, confirmando que o EGPU-MIP-TC foi mais efetivo na capacidade de reconhecer seletivamente o analito na presença dos interferentes CTC e OTC. Após as etapas de síntese dos MIP/NIP e confecção dos eletrodos, otimização dos parâmetros, avaliações e testes de sensibilidade e seletividade dos EGPU, os eletrodos foram submetidos à aplicação em duas amostras de medicamentos comerciais, TetraMed&reg; 500 mg e genérico de cloridrato de tetraciclina 500 mg e uma amostra sintética de urina. Os resultados foram comparados ao método oficial por HPLC, apresentando 95 % de confiança, de acordo com o teste t-Student. / In this work, graphite-polyurethane composites electrodes were modified with methacrylate molecularly imprinted polymers (MIP-TC) in order to evaluate the electrodes in the determination of tetracycline (TC) antibiotic in pharmaceutical formulations as well as in biological fluid. The work aimed to contribute in development of a sensor with better performance about the sensitivity and selectivity of the composites electrodes modified in quantification of this analyte. Electroanalytical techniques such as cyclic voltammetry (CV) and differential pulse voltammetry (DPV) were used to evaluate the selectivity and sensitivity of the composite electrodes in the detection of tetracycline. The parameters optimization, such as MIP composition (5.0 %, m/m), pulse amplitude (50 mV), scan rate (10 mV s-1), accumulation time (300 s), accumulation potential [+ 0.7 V (vs. SCE)], and MIP granulometry (150 to 250 &mu;m), using differential pulse anodic stripping voltammetry was done to maximize the determination of tetracycline in phosphate buffer 0.1 mol·L-1 pH 2.5 resulting in LOD of 0.555 &mu;mol L-1, 2.70 &mu;mol L-1 and 4.71 &mu;mol L-1, respectively for the EGPU-MIP-TC, EGPU and EGPU-NIP, without the need for surface renovation between the measures. A linear dynamic range from 4.0 to 60.0 &mu;mol L-1, 8.0 to 60.0 &mu;mol L-1 and 20.0 to 100.0 &mu;mol L-1, respectively for the EGPU-MIP-TC, EGPU and EGPU-NIP was observed for the anodic peak at + 0.9 V (vs. SCE). The EGPU were also tested regarding the selectivity compared to possible interferents, such as chlortetracycline (CTC) and oxytetracycline (OTC) for the interference study. In all cases, the interference of EGPU-MIP-TC was lower than the one that was got with EGPU-NIP, confirming that the EGPU-MIP-TC was more selective than the non-imprinted polymer in the capacity of recognizing, selectively, the analyte in presence of CTC and OTC interferents. After the steps of synthesis of MIP/NIP and electrodes confection, parameters optimization, evaluation and EGPU sensitivity and selectivity studies, the electrodes were submitted to the application in two commercial drugs containing 500 mg of tetracycline cloridrate, TetraMed&reg; and generic; and a synthetic urine sample. The results were compared to the official method by HPLC, presenting 95 % confidence according to the t-Student test.
8

Estudo eletroquímico e desenvolvimento de novas metodologias eletroanalíticas para a determinação de antidepressivos tricíclicos e neurotransmissores / Electrochemical study and development of new electroanalytical methodologies for the determination of tricyclic antidepressants and neurotransmiters

Toledo, Renata Alves de 17 February 2006 (has links)
Neste trabalho, são abordados os estudos eletroquímicos e químico-quânticos, bem como o desenvolvimento de metodologias analíticas para o antidepressivo tricíclico imipramina e para o neurotransmissor dopamina. Os experimentos foram realizados em solução tampão Britton Robinson (BR) 0,10 mol L-1 no pH de melhor resposta analítica para os referidos compostos. Com base nos parâmetros eletroquímicos extraídos das técnicas de voltametria cíclica e de onda quadrada, utilizando-se um eletrodo de grafite-poliuretana (GPU), foi possível diagnosticar o grau de reversibilidade das reações, a presença ou não de processos de adsorção e também o número de prótons e elétrons envolvidos nas reações eletroquímicas. Quanto aos cálculos químico-quânticos, a representação gráfica do HOMO (orbital molecular de mais alta energia ocupado) e os cálculos das cargas atômicas derivadas do potencial eletrostático forneceram uma estimativa do provável sítio de oxidação dos compostos. Os resultados indicaram que a reação de oxidação da imipramina é irreversível e dependente da adsorção do reagente na superfície do eletrodo, ocorrendo a formação subseqüente de um dímero em uma etapa química posterior à transferência de dois elétrons e um próton. O provável sítio de oxidação da molécula abrange a região do átomo de nitrogênio do anel, salientando que após a transferência de dois elétrons há uma deslocalização de cargas pelo anel aromático, fato este que sugere a formação do dímero na posição 2. Paralelamente, experimentos de eletrólise a potencial controlado foram realizados com o objetivo de gerar produtos de reação para serem analisados pela técnica de espectroscopia de massa com ionização por electrospray (ESI-MS). Tomando-se por base os resultados obtidos pelas técnicas voltamétricas, pelos cálculos químico-quânticos e pelos espectros de massa, foi sugerido o provável mecanismo de oxidação da imipramina nas condições estudadas. A metodologia analítica desenvolvida para a imipramina é rápida, sensível e exata para a análise de rotina em comprimidos de Tofranil®. A sensibilidade alcançada pela metodologia permitiu ainda a análise direta de concentrações plasmáticas terapêuticas do antidepressivo e de seu metabólito (desipramina) em amostra de soro humano sintético. No entanto, a seletividade da metodologia ficou comprometida pela proximidade dos potenciais de pico dos dímeros formados após a oxidação da imipramina (-41 mV) e da desipramina (23 mV). A aplicação de um método matemático de deconvolução (Origin 6.0) tornou possível a determinação simultânea da imipramina e da desipramina. A dopamina, por sua vez, é oxidada a dopamina orto quinona em um processo reversível com a adsorção de reagente e produto na superfície do eletrodo. O processo envolve a participação de dois elétrons e dois prótons. A metodologia analítica desenvolvida para a dopamina foi aplicada na análise de rotina em ampolas de Revivan® com boa exatidão e precisão. Além disso, a sensibilidade e a seletividade alcançada pela metodologia resultou na determinação de dopamina em fluído cerebrospinal sintético. A separação dos picos de oxidação da dopamina (Ep = 200 mV) e do ácido ascórbico (Ep = 40 mV) deve-se, provavelmente, às interações eletrostáticas favoráveis entre a superfície do eletrodo de GPU e o ânion ascorbato. De maneira geral, os resultados obtidos foram bastante satisfatórios para as determinações pretendidas, concluindo que o eletrodo de GPU é um material promissor para a análise de moléculas de interesse biológico. / In this work, the electrochemical and quantum-chemical studies are discussed, as well as the development of analytical methodologies for the imipramine tricyclic antidepressant and for the dopamine neurotransmitter. Experiments were performed in 0.10 mol L-1 Britton Robinson (BR) buffer solution at the best analytical response pH for the mentioned compounds. From the electrochemical parameters extracted of cyclic and square wave voltammetric techniques, using a graphite-polyurethane electrode (GPU), it was possible to diagnose the reactions reversible degree, the presence or not of adsorptions processes and also the number of protons and electrons involved in the electrochemical reactions. Concerning to the quantum-chemical calculations, the graphic representation of HOMO (Highest Occupied Molecular Orbital) and the calculation of the atomic charge derived from electrostatic potential provided an estimation of the probable oxidation sites of the compounds. The results indicated that the oxidation reaction of imipramine is reversible and dependent of the reagent adsorption at the electrode surface, occuring the formation of a dimer in a chemical step after the transference of two electrons and one proton. The probable oxidation site of the molecule includes the nitrogen atom region of the ring, emphasizing that after the transference of the two electrons there is a deslocalization of the charges though the aromatic ring, suggesting the formation of the dimeric specie at postion 2. At the same time, experiments of controlled potential electrolysis were carried out in order to generate reaction products to be analysed by electrospray ionization mass espectrosmmetry (ESI-MS). From the results obtained by voltammetric techniques, by quantum-chemical calculations and by mass spectroscopy, it was suggested a probable mechanism for the imipramine oxidation in the studied conditions. The analytical methodology developed for imipramine is fast, sensible and accurate for routine analysis in Tofranil® tablets. The reached sensibility also allowed the direct analysis of therapeutical plasmatic concentrations of the antidepressant and its methabolic (desipramine) in synthetic human serum sample. However, the selectivity of the methodology was compromised by the peak potentials proximity of the dimers formed after the oxidation of imipramine (-41 mV) and of desipramine (23 mV). The application of a deconvolution mathematical xviii method (Origin 6.0) permitted the simultaneous analysis of imipramine and desipramine. On the other hand, dopamine is oxidized to dopamine ortho-quinone in a reversible process with the adsorption of reagent and product at the electrode surface. The process involves the participation of two electrons and two protons. The analytical methodology developed for dopamine was applied in the routine analysis in Revivan® injections with good accuracy and precision. Besides that, the sensitivity and the selectivity reached by the methodology resulted in the determination of dopamine in synthetic cerebrospinal fluid. The separation of the oxidation peaks of dopamine (Ep = 200 mV) and of ascorbic acid (Ep = 40 mV) is probably due to the favorable electrostatic interactions between the GPU electrode surface and the ascorbate anion. In general way, the obtained results were very satisfatory for the desirable determinations, concluding that the GPU electrode is a promissing material for the analysis of biological interest molecules.
9

Determinação de tetraciclina utilizando eletrodos compósitos grafite-poliuretana modificados com polímeros metacrilatos com impressão molecular / Determination of tetracycline using graphite-polyuretane composites electrodes modified with methacrylate molecularly imprinted polymers

Clarindo, José Eduardo dos Santos 27 September 2017 (has links)
Neste trabalho propôs-se desenvolver eletrodos compósitos à base de grafite-poliuretana modificados com polímeros metacrilatos com impressão molecular (MIP-TC), visando a determinação do antibiótico tetraciclina em formulações farmacêuticas e urina sintética. O trabalho também visou contribuir no desenvolvimento de um sensor com melhor desempenho no que diz respeito à sensibilidade e seletividade do eletrodo compósito modificado, na quantificação do analito/molécula molde em matrizes complexas. Técnicas eletroanalíticas, tais como voltametria cíclica (CV) e voltametria de pulso diferencial (DPV) foram utilizadas para avaliar a resposta em termos de sensibilidade e seletividade do eletrodo compósito na detecção da tetraciclina (TC), proposto neste trabalho. A otimização dos parâmetros, tais como composição do MIP (5,0 %, m/m), amplitude de pulso (50 mV), velocidade de varredura (10 mV s-1), tempo (300 s) e potencial de acumulação [(+ 0,7 V (vs. SCE)] e faixa granulométrica do MIP (150 a 250 &mu;m), usando voltametria de redissolução anódica por pulso diferencial foi realizada para maximizar a determinação da tetraciclina em tampão fosfato 0,10 mol L -1 (pH 2,5), permitindo obter limites de detecção de 0,555 &mu;mol L-1, 2,70 &mu;mol L-1 e 4,71 &mu;mol L-1, respectivamente, para o EGPU-MIP-TC, EGPU e EGPU-NIP, sem necessidade de renovação da superfície do eletrodo entre as sucessivas medidas. Regiões lineares entre 4,0 e 60,0 &mu;mol L-1, 8,0 e 60,0 &mu;mol L-1 e 20,0 e 100,0 &mu;mol L-1/sup> foram observadas, respectivamente, para o EGPU-MIP-TC, EGPU e EGPU-NIP, para o pico anódico em + 0,9 V (vs. SCE). Os EGPU também foram testados quanto à seletividade frente à possíveis interferentes, sendo utilizados clortetraciclina (CTC) e oxitetraciclina (OTC) para os testes de interferência. Em todos os casos, a interferência do EGPU-MIP-TC foi menor do que a obtida com o EGPU-NIP, confirmando que o EGPU-MIP-TC foi mais efetivo na capacidade de reconhecer seletivamente o analito na presença dos interferentes CTC e OTC. Após as etapas de síntese dos MIP/NIP e confecção dos eletrodos, otimização dos parâmetros, avaliações e testes de sensibilidade e seletividade dos EGPU, os eletrodos foram submetidos à aplicação em duas amostras de medicamentos comerciais, TetraMed&reg; 500 mg e genérico de cloridrato de tetraciclina 500 mg e uma amostra sintética de urina. Os resultados foram comparados ao método oficial por HPLC, apresentando 95 % de confiança, de acordo com o teste t-Student. / In this work, graphite-polyurethane composites electrodes were modified with methacrylate molecularly imprinted polymers (MIP-TC) in order to evaluate the electrodes in the determination of tetracycline (TC) antibiotic in pharmaceutical formulations as well as in biological fluid. The work aimed to contribute in development of a sensor with better performance about the sensitivity and selectivity of the composites electrodes modified in quantification of this analyte. Electroanalytical techniques such as cyclic voltammetry (CV) and differential pulse voltammetry (DPV) were used to evaluate the selectivity and sensitivity of the composite electrodes in the detection of tetracycline. The parameters optimization, such as MIP composition (5.0 %, m/m), pulse amplitude (50 mV), scan rate (10 mV s-1), accumulation time (300 s), accumulation potential [+ 0.7 V (vs. SCE)], and MIP granulometry (150 to 250 &mu;m), using differential pulse anodic stripping voltammetry was done to maximize the determination of tetracycline in phosphate buffer 0.1 mol·L-1 pH 2.5 resulting in LOD of 0.555 &mu;mol L-1, 2.70 &mu;mol L-1 and 4.71 &mu;mol L-1, respectively for the EGPU-MIP-TC, EGPU and EGPU-NIP, without the need for surface renovation between the measures. A linear dynamic range from 4.0 to 60.0 &mu;mol L-1, 8.0 to 60.0 &mu;mol L-1 and 20.0 to 100.0 &mu;mol L-1, respectively for the EGPU-MIP-TC, EGPU and EGPU-NIP was observed for the anodic peak at + 0.9 V (vs. SCE). The EGPU were also tested regarding the selectivity compared to possible interferents, such as chlortetracycline (CTC) and oxytetracycline (OTC) for the interference study. In all cases, the interference of EGPU-MIP-TC was lower than the one that was got with EGPU-NIP, confirming that the EGPU-MIP-TC was more selective than the non-imprinted polymer in the capacity of recognizing, selectively, the analyte in presence of CTC and OTC interferents. After the steps of synthesis of MIP/NIP and electrodes confection, parameters optimization, evaluation and EGPU sensitivity and selectivity studies, the electrodes were submitted to the application in two commercial drugs containing 500 mg of tetracycline cloridrate, TetraMed&reg; and generic; and a synthetic urine sample. The results were compared to the official method by HPLC, presenting 95 % confidence according to the t-Student test.
10

Estudo eletroquímico e desenvolvimento de novas metodologias eletroanalíticas para a determinação de antidepressivos tricíclicos e neurotransmissores / Electrochemical study and development of new electroanalytical methodologies for the determination of tricyclic antidepressants and neurotransmiters

Renata Alves de Toledo 17 February 2006 (has links)
Neste trabalho, são abordados os estudos eletroquímicos e químico-quânticos, bem como o desenvolvimento de metodologias analíticas para o antidepressivo tricíclico imipramina e para o neurotransmissor dopamina. Os experimentos foram realizados em solução tampão Britton Robinson (BR) 0,10 mol L-1 no pH de melhor resposta analítica para os referidos compostos. Com base nos parâmetros eletroquímicos extraídos das técnicas de voltametria cíclica e de onda quadrada, utilizando-se um eletrodo de grafite-poliuretana (GPU), foi possível diagnosticar o grau de reversibilidade das reações, a presença ou não de processos de adsorção e também o número de prótons e elétrons envolvidos nas reações eletroquímicas. Quanto aos cálculos químico-quânticos, a representação gráfica do HOMO (orbital molecular de mais alta energia ocupado) e os cálculos das cargas atômicas derivadas do potencial eletrostático forneceram uma estimativa do provável sítio de oxidação dos compostos. Os resultados indicaram que a reação de oxidação da imipramina é irreversível e dependente da adsorção do reagente na superfície do eletrodo, ocorrendo a formação subseqüente de um dímero em uma etapa química posterior à transferência de dois elétrons e um próton. O provável sítio de oxidação da molécula abrange a região do átomo de nitrogênio do anel, salientando que após a transferência de dois elétrons há uma deslocalização de cargas pelo anel aromático, fato este que sugere a formação do dímero na posição 2. Paralelamente, experimentos de eletrólise a potencial controlado foram realizados com o objetivo de gerar produtos de reação para serem analisados pela técnica de espectroscopia de massa com ionização por electrospray (ESI-MS). Tomando-se por base os resultados obtidos pelas técnicas voltamétricas, pelos cálculos químico-quânticos e pelos espectros de massa, foi sugerido o provável mecanismo de oxidação da imipramina nas condições estudadas. A metodologia analítica desenvolvida para a imipramina é rápida, sensível e exata para a análise de rotina em comprimidos de Tofranil®. A sensibilidade alcançada pela metodologia permitiu ainda a análise direta de concentrações plasmáticas terapêuticas do antidepressivo e de seu metabólito (desipramina) em amostra de soro humano sintético. No entanto, a seletividade da metodologia ficou comprometida pela proximidade dos potenciais de pico dos dímeros formados após a oxidação da imipramina (-41 mV) e da desipramina (23 mV). A aplicação de um método matemático de deconvolução (Origin 6.0) tornou possível a determinação simultânea da imipramina e da desipramina. A dopamina, por sua vez, é oxidada a dopamina orto quinona em um processo reversível com a adsorção de reagente e produto na superfície do eletrodo. O processo envolve a participação de dois elétrons e dois prótons. A metodologia analítica desenvolvida para a dopamina foi aplicada na análise de rotina em ampolas de Revivan® com boa exatidão e precisão. Além disso, a sensibilidade e a seletividade alcançada pela metodologia resultou na determinação de dopamina em fluído cerebrospinal sintético. A separação dos picos de oxidação da dopamina (Ep = 200 mV) e do ácido ascórbico (Ep = 40 mV) deve-se, provavelmente, às interações eletrostáticas favoráveis entre a superfície do eletrodo de GPU e o ânion ascorbato. De maneira geral, os resultados obtidos foram bastante satisfatórios para as determinações pretendidas, concluindo que o eletrodo de GPU é um material promissor para a análise de moléculas de interesse biológico. / In this work, the electrochemical and quantum-chemical studies are discussed, as well as the development of analytical methodologies for the imipramine tricyclic antidepressant and for the dopamine neurotransmitter. Experiments were performed in 0.10 mol L-1 Britton Robinson (BR) buffer solution at the best analytical response pH for the mentioned compounds. From the electrochemical parameters extracted of cyclic and square wave voltammetric techniques, using a graphite-polyurethane electrode (GPU), it was possible to diagnose the reactions reversible degree, the presence or not of adsorptions processes and also the number of protons and electrons involved in the electrochemical reactions. Concerning to the quantum-chemical calculations, the graphic representation of HOMO (Highest Occupied Molecular Orbital) and the calculation of the atomic charge derived from electrostatic potential provided an estimation of the probable oxidation sites of the compounds. The results indicated that the oxidation reaction of imipramine is reversible and dependent of the reagent adsorption at the electrode surface, occuring the formation of a dimer in a chemical step after the transference of two electrons and one proton. The probable oxidation site of the molecule includes the nitrogen atom region of the ring, emphasizing that after the transference of the two electrons there is a deslocalization of the charges though the aromatic ring, suggesting the formation of the dimeric specie at postion 2. At the same time, experiments of controlled potential electrolysis were carried out in order to generate reaction products to be analysed by electrospray ionization mass espectrosmmetry (ESI-MS). From the results obtained by voltammetric techniques, by quantum-chemical calculations and by mass spectroscopy, it was suggested a probable mechanism for the imipramine oxidation in the studied conditions. The analytical methodology developed for imipramine is fast, sensible and accurate for routine analysis in Tofranil® tablets. The reached sensibility also allowed the direct analysis of therapeutical plasmatic concentrations of the antidepressant and its methabolic (desipramine) in synthetic human serum sample. However, the selectivity of the methodology was compromised by the peak potentials proximity of the dimers formed after the oxidation of imipramine (-41 mV) and of desipramine (23 mV). The application of a deconvolution mathematical xviii method (Origin 6.0) permitted the simultaneous analysis of imipramine and desipramine. On the other hand, dopamine is oxidized to dopamine ortho-quinone in a reversible process with the adsorption of reagent and product at the electrode surface. The process involves the participation of two electrons and two protons. The analytical methodology developed for dopamine was applied in the routine analysis in Revivan® injections with good accuracy and precision. Besides that, the sensitivity and the selectivity reached by the methodology resulted in the determination of dopamine in synthetic cerebrospinal fluid. The separation of the oxidation peaks of dopamine (Ep = 200 mV) and of ascorbic acid (Ep = 40 mV) is probably due to the favorable electrostatic interactions between the GPU electrode surface and the ascorbate anion. In general way, the obtained results were very satisfatory for the desirable determinations, concluding that the GPU electrode is a promissing material for the analysis of biological interest molecules.

Page generated in 0.128 seconds