• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 68
  • Tagged with
  • 68
  • 68
  • 66
  • 64
  • 45
  • 22
  • 21
  • 21
  • 20
  • 18
  • 18
  • 16
  • 15
  • 14
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

EFEITO DE DIFERENTES PROTOCOLOS DE APLICAÇÃO DE ADESIVOS UNIVERSAIS NAS PROPRIEDADES E LONGEVIDADE DA UNIÃO À DENTINA / Effect of different universal adhesive application protocols on the properties and longevity of bond to dentin

Pérez, Miguel Angel Muñoz 07 February 2014 (has links)
Made available in DSpace on 2017-07-24T19:22:33Z (GMT). No. of bitstreams: 1 Tese Miguel Munoz Doutorado Odontologia 2014.pdf: 3888005 bytes, checksum: 9a25e76295a44d9cdb11d6afb38c9041 (MD5) Previous issue date: 2014-02-07 / Fundação Araucária de Apoio ao Desenvolvimento Científico e Tecnológico do Paraná / The aim of the present study was to make an in vitro evaluation of the properties and stability of the bond to dentin of new universal adhesive systems applied according to the etch-and-rinse (ER) and self-etching (SE) adhesive strategies. The specific objectives for each of the three studies were: To evaluate the microtensile bond strength (RU), nanoleakage (NI) and degree of conversion (DC) in the time intervals of 24 h (Experiment 1) and six months (Experiment 2) of the universal adhesive systems applied in accordance with the manufacturers’ recommendations for strategies ER and SE; and the effect of an additional hydrophobic layer (Experiment 3, in the immediate time interval) on these same properties. The occlusal surfaces of 140 third molars were flattened until dentin was obtained, and then the teeth were randomly allocated to 28 groups (n=5). In Experiments 1 and 2, 40 teeth were divided into eight groups according to the adhesive used (Peak Universal [Pk], Scotchbond Universal [Sc], Allbond Universal [Al]) and adhesive strategy (ER and SE), with the ER adhesive system Adper Single Bond 2 (SB) and self-etching Clearfil SE Bond (CSE) used as controls. For Experiment 3, 60 teeth were divided into 12 groups according to the adhesive (Sc, Al, G-Bond Plus [Gbp]), adhesive strategy (ER and SE) and with or without hydrophobic layer (Heliobond, HE). After application of the variables adhesives and restorative procedure, the teeth were stored in distilled water (37oC/24 h) and cut to obtain dentin-resin sticks (0.8 mm2 cross-section) which were submitted to the RU and NI tests in the following time intervals: immediate (Experiments 1 and 3) and six months (Experiment 2); and analysis of DC in the immediate time interval. The data of Experiment 1 were submitted to one-way analysis of variance (Adhesive Strategy) and those of Experiments 2 and 3, to twoway analysis of variance (Adhesive strategy vs. Time intervals; and Adhesive strategy vs. Hydrophobic layer) respectively. The analyses were complemented by the Tukey Test (α=0.05). The RU results obtained in Experiment 1 demonstrated that only PkEr and PkSe were similar to the respective control groups (p>0.05); that the other universal materials resulted in lower RU means than those of their controls ER and SE (p<0.05) and that AlSe presented the lowest mean RU values (p<0.05). For NI, the Groups ScEr, ScSe, AlSe, and AlEr presented low levels of NI similar to those of the control groups (p<0.05). For DC, only Group ScSe demonstrated low DC when compared with the other materials (p<0.05). According to the results of Experiment 2, the systems Pk and AlEr presented a reduction in RU (p<0.05) and only Pk underwent significant degradation (NI) after six months (p<0.05). According to Experiment 3, Al and Gbp obtained higher RU results with the ER strategy (p<0.05); the use of HE increased the RU only in strategy SE (p<0.05); a low level of NI was observed only in Groups Sc and Al with the CON+HE strategy and in Group Gbp with SE+HE; Groups Sc and Gbp presented a high DC when used with the ER strategy, which was increased with the application of HE (p<0.05). The DC if Al was similar under all the conditions. From the three experiments of which this study was composed, it could be concluded that: 1) the universal adhesives presented a 13 material-dependent behavior in both strategies (ER and SE) and were inferior, in at least one of the properties evaluated (RU, Nl or DC), when compared with the control adhesives (CSE and SB); 2) In general, after six months the adhesives SE maintained the most stable RU and NI values, which appears to be related mainly to their capacity to form a chemical bond to dental substrate; 3) The use of a hydrophobic layer in strategy SE was able to increase the RU and DC of universal adhesives and the reduction in NI was more dependent on the composition of the adhesive than on the adhesive strategy. / O objetivo do presente trabalho foi avaliar in vitro as propriedades e longevidade da união à dentina dos novos sistemas adesivos universais aplicados segundo as estratégias adesivas convencional (CON) e autocondicionante (AC). Os objetivos específicos para cada um dos três estudos foram: avaliar a resistência de união à microtração (RU), a nanoinfiltração (NI) e o grau de conversão (GC) no tempo imediato - 24 h - experimento 1) e seis meses (Experimento 2) dos sistemas adesivos universais para as estratégias CON e AC; e o efeito de uma camada hidrofóbica adicional (Experimento 3, no tempo imediato) sobre essas mesmas propriedades. Cento e quarenta terceiros molares foram planificados na face oclusal até se obter dentina e alocados aleatoriamente em 28 grupos (n=5). Nos Experimentos 1 e 2, 40 dentes foram divididos em oito grupos de acordo com o adesivo (Peak Universal [Pk], Scotchbond Universal [Sc], Allbond Universal [Al]) e estratégia adesiva (CON e AC) tendo como controle, o sistema adesivo convencional Adper Single Bond 2 (SB) e o autocondicionante Clearfil SE Bond (CSE). Para o Experimento 3, 60 dentes foram divididos em 12 grupos de acordo com o adesivo (Sc, Al, G-Bond Plus [Gbp]), estratégia adesiva (CON e AC) e com a presença ou não de camada hidrofóbica (Heliobond, HE). Após aplicação das variáveis adesivas e do procedimento restaurador, os dentes foram armazenados em água destilada (37oC/24 h) e cortados para obter palitos de dentina-resina (0,8 mm2 de secção transversal) sendo submetidos aos teste de RU e NI nos tempos imediato (Experimentos 1 e 3) e também seis meses (Experimento 2); e análise de GC no tempo imediato. Os dados do Experimento 1 foram submetidos à análise de variância de um fator (Estratégia Adesiva) e os dos Experimentos 2 e 3, à de dois fatores (Estratégia adesiva versus Tempos de análise; e Estratégia adesiva versus Camada hidrofóbica), respectivamente. As análises foram complementadas pelo teste de Tukey (α=0,05). Os resultados de RU obtidos no Experimento 1 demonstraram que apenas PkCon e PkAc foram similares aos respectivos grupos controle (p>0,05), que os outros materiais universais resultaram em médias de RU inferiores aos seus controles CON e AC (p<0,05) e que AlAc apresentou as médias mais baixas de RU (p<0,05). Para NI, ScCon, ScAc, AlAc, e AlCon apresentaram baixos níveis de NI similares aos grupos controle (p<0,05). Para GC, unicamente ScAc demostrou baixo GC, quando comparado com os outros materiais (p<0.05). Segundo os resultados do Experimento 2, os sistemas Pk e AlCon apresentaram diminuição da RU (p<0,05) e apenas Pk teve degradação significativa (NI) após seis meses (p<0,05). De acordo com o Experimento 3, Al e Gbp obtiveram maiores resultados de RU na estratégia CON (p<0,05); o uso de HE aumentou a RU unicamente na estratégia AC (p<0,05); baixa NI foi observada somente em Sc e Al na estratégia CON+HE e em Gbp em AC+HE; Sc e Gbp apresentaram alto GC quando usados em estratégia CON, que foi aumentado com a aplicação de HE (p<0,05). O GC de Al foi similar em todas as condições. A partir dos três experimentos que compõem o presente trabalho, pôdese concluir que: 1) os adesivos universais apresentaram um comportamento 11 dependente do material em ambas estratégias (CON e AC) e foram inferiores, pelo menos em uma das propriedades avaliadas (RU, Nl ou GC), quando comparados aos adesivos controle (CSE e SB); 2) Em geral, após seis meses os adesivos AC mantém mais estáveis os valores de RU e NI, o que parece estar relacionado principalmente à sua capacidade de união química ao substrato dental; 3) A utilização de uma camada hidrofóbica na estratégia AC pôde aumentar a RU e o GC de adesivos universais e a redução da NI foi mais dependente da composição do adesivo do que da estratégia adesiva.
52

EFEITO DA DENSIDADE DE ENERGIA DA LUZ NA ADESÃO ENTRE PINOS DE FIBRA E DENTINA RADICULAR / Effects of energy density of light-activation of adhesive systems on bonding fiber posts to root canals

Szesz, Anna Luiza 25 February 2014 (has links)
Made available in DSpace on 2017-07-24T19:22:35Z (GMT). No. of bitstreams: 1 ANNA LUIZA SZESZ.pdf: 3989892 bytes, checksum: 237bfbd8af89362f6139a3c445f884d8 (MD5) Previous issue date: 2014-02-25 / This study evaluated, the intensity of light transmitted through a translucent fiber post ( Whitepost DC n° 2) using an experimental system and the effect of different densities of light energy in adhesive properties: degree of conversion within the hybrid layer (DC), nanoleakage (NL) and bond strength (μTBS) of two adhesive systems to dentin (Ambar [AM] and Excite DSC [EX]). The roots of 72 human premolars were prepared endodontically and divided into groups (n=6) according to the combination of factors: adhesive system (AM and EX) and energy density (16, 48 and 288 J/cm²). After cementing fiber post the roots with fiber post were subjected to μTBS (push-out) (n = 7) in a universal testing machine (0.5 mm/min). DC analysis (%) in situ (n = 2) was made by micro -Raman spectroscopy and NL was evaluated by SEM after immersing the samples in 50% silver nitrate (n=3). Data from the μTBS, NL, and DC of each adhesive were analyzed by 3-way repeated measures ANOVA (adhesive vs. Energy density vs. root third) and Tukey test (α = 0.05) . To measure the intensity of light transmitted through the post, the measuring device consisted of a light beam pulsed laser focusing perpendicular to the bottom surface of the post, and in the direction parallel to the axis of the post detector capable of measuring the scattered light at the post. To simulate the variation of light intensity, filters were used in this system with optical density varying the light intensity of 100, 25 and 10%. The results of μTBS (MPa) showed a significant difference for the middle and apical (p <0.05) thirds when an increase in energy density from 16 to 48 and 288 J/cm²respectively. The DC (%) significantly increased the density of 288 J/cm² in the middle and apical thirds compared the same with the lower energy density of 16 J/cm² (p < 0.05). The NL (%) decreases significantly from the energy density of 48 J/cm² in the middle and apical (p thirds < 0.05) and remained constant for the density of 288 J/cm² (p > 0.05), in general, none of the tests results showed a significant difference when the cervical third was evaluated . Regarding the results of the intensity of light scattered by the post, light intensity reduced to 45,5% in the cervical region, to 14,2% and 5,3% in the middle and apical thirds, respectively. As for simulating the variation of light intensity, it was observed that the increase of the intensity of light incident on the base of the cervical post provides a gain of intensity of light reaching the apical level. / Este estudo avaliou, através de um sistema experimental, a intensidade de luz transmitida por um pino de fibra translúcido (Whitepost DC n°2) e o efeito de diferentes densidades de energia da luz nas propriedades adesivas: grau de conversão no interior da camada híbrida (GC), nanoinfiltração (NI) e resistência de união (RU) à dentina de dois sistemas adesivos (Ambar [AM] e Excite DSC [EX]). As raízes de 72 pré-molares humanos foram preparadas endodonticamente e divididas em grupos (n=6) de acordo com a combinação dos principais fatores: sistema adesivo (AM e EX), e densidade de energia (16, 48 e 288 J/cm²). Após cimentação dos pinos de fibra, foi testado a RU (push-out) (n=7) em uma máquina de ensaios universal (0,5 mm/min). A análise do GC (%) in situ (n=2) foi feita através da espectroscopia micro-Raman e a NI foi avaliada por MEV após a imersão das amostras em 50% em nitrato de prata (n=3). Os dados de RU, GC e NI de cada adesivo foram analisados por ANOVA de 3 fatores de medidas repetidas (adesivo vs. densidade de energia vs. terço radicular) e teste de Tukey (α = 0,05). Para mensuração da intensidade de luz transmitida pelo pino, o sistema era constituído por um feixe de luz laser pulsado incidindo perpendicularmente a superfície da base do pino, e na direção paralela ao eixo do pino um detector capaz de mensurar a luz espalhada no pino. Para simular a variação da intensidade de luz foram utilizados junto a esse sistema filtros de densidade óptica, variando a intensidade de luz em 100, 25 e 10%. Os resultados de RU (MPa) demonstraram diferença significativa para os terços médio e apical (p < 0,05) quando houve aumento da densidade de energia de 16 para 48 e 288 J/cm² respectivamente. O GC (%) aumentou significativamente na densidade de 288 J/cm² nos terços médio e apical quando comparado os mesmos terços com a menor densidade de energia 16 J/cm² (p <0,05). A NI (%) diminui significativamente a partir da densidade de energia de 48 J/cm² nos terços médio e apical (p < 0,05) e se manteve constante para a densidade de 288 J/cm² (p > 0,05). Em geral, nenhum dos testes apresentaram resultados com diferença significativa quando o terço cervical foi avaliado. Em relação aos resultados da intensidade da luz espalhada pelo pino observamos que na região cervical a intensidade de luz reduz para 45,5 % no terço médio para 14,2 % e para apical 5,3%. Quanto a simulação da variação da intensidade da luz, foi possível observar que o aumento da intensidade de luz incidente na base cervical do pino proporciona um ganho de intensidade de luz que chega ao nível apical.
53

Influência de propriedades físico químicas dos materiais resinosos e da técnica de inserção na adaptação marginal de restaurações classe II / Influence of physicochemical properties of resin materials and insertion technique on marginal adaptation of class II restorations

Silvia Maria Ribeiro de Alencar Gonçalves 25 February 2013 (has links)
A contração de polimerização das resinas compostas é uma característica indesejável que compromete a integridade da interface dente/restauração. O objetivo deste estudo foi avaliar in vitro a influência de diferentes materiais usados em restaurações classe II de resina composta, quanto ao grau de conversão, tensão de contração, resistência a flexão, módulo de elasticidade e formação de fenda marginal. Foram realizados preparos classe II com dimensões de 4x4x2mm em terceiros molares recém-extraídos para a avaliação da formação de fenda marginal. As cavidades foram niveladas com cimento de ionômero de vidro Riva Light Cure (SDI) (CIV), resina de baixa contração SureFilSDR (Dentsply) (SDR), resina flow FiltekZ350Flow (3M/ESPE) (Z350F) e resina composta FiltekP90 (3M/ESPE) (P90). As restaurações (n=3) foram avaliadas com lupa estereoscópica. A resistência a flexão foi avaliada por meio de ensaio de flexão em três pontos. Para este ensaio foram confeccionados dez corpos de prova (n=10) de cada material com dimensões de 10x2x1mm. Para o teste de tensão de contração foram utilizados cilindros de polimetacrilato com 5 mm de diâmetro e 13 ou 28mm de comprimento. Os bastões foram fixados na EMIC com um espaço de 2mm entre eles, onde os materiais foram inseridos. Foram realizadas cinco repetições para cada grupo (n=5) e a tensão proveniente da contração foi medida por até 10 minutos após o início da fotopolimerização. O Grau de Conversão (GC) foi determinado por espectroscopia no infravermelho com transformada de Fourier (FTIR). Os resultados foram tratados estatisticamente por análise de variância (ANOVA) e Teste de Tukey (p<0,05). Fenda marginal: Z350F = CIV > SDR = P90. Tensão de contração: Z350F > SDR > CIV = P90. Resistência a flexão: P90 > SDR = Z350F > CIV. Módulo de Elasticidade: P90 > CIV = SDR = Z350F. GC: Z350F = SDR > P90 > CIV. Conclusões: existe correlação entre a formação de fenda marginal e as propriedades físico químicas dos materiais testados, sendo as resinas de baixa contração que proporcionaram melhor adaptação marginal; existe correlação entre resistência a flexão, módulo de elasticidade, tensão de contração e a composição dos materiais, já que os compósitos com melhores resultados foram os que apresentaram os maiores percentuais de carga, no entanto, maior grau de conversão não representou melhores propriedades mecânicas. / The shrinkage of composite resin polymerization is an undesirable characteristic that compromises the integrity of the tooth / restoration interface. The aim of this study was to evaluate in vitro the influence of different materials used in composite resin class II restorations in terms of contraction stress, flexural strength, degree of conversion and marginal gap formation. Class II preparation were performed with 4x4x2mm dimensions in third molars freshly extracted for the evaliation of marginal gap formation. The cavities were filled with Riva Light Cure (SDI) glass ionomer cement (CIV), SureFil SDR (Dentsply) low shrinkage resin (SDR), Filtek Z350Flow (3M/ESPE) flowable composite (Z350F) and Filtek P90 (3M/ESPE) composite resin (P90). The restorations (n = 3) were evaluated with magnifying stereoscopic. The flexural strength was assessed by means of three point bending test. For this test ten specimens (n = 10) of each material were made, each with 10x2x1mm dimensions. For the shrinkage stress test polymethacrylate cylinders with 5 mm in diameter and 13 or 28mm in length were used. Bats were attached to the EMIC with a 2mm space between them, where the materials were inserted. The test were repeated five times for each group (n = 5) and the contraction stress was measured for up to 10 minutes after initiation of photopolymerization. The Degree of Conversion (DC) was determined by Fourier transform infrared (FTIR). The results were statistically analyzed by the variance analysis (ANOVA) and Tukey test (p <0.05). Marginal gap: Z350F = CIV > SDR = P90. Contraction stress: Z350F > SDR> CIV = P90. Flexural strength: P90 > SDR = Z350F > CIV. Elasticity Modulus: P90 > CIV = SDR = Z350F. DC: Z350F = SDR > P90 > CIV. Conclusion: There is a correlation between formation of marginal gap and physicochemical properties of the materials tested whereas low shrinkage resins provided better marginal adaptation; correlation exists between flexural strength, elastic modulus, shrinkage stress and material composition, since better results were obtained from composites with larger quantity of load; higher conversion degree did not represent better mechanical properties.
54

Influência de propriedades físico químicas dos materiais resinosos e da técnica de inserção na adaptação marginal de restaurações classe II / Influence of physicochemical properties of resin materials and insertion technique on marginal adaptation of class II restorations

Silvia Maria Ribeiro de Alencar Gonçalves 25 February 2013 (has links)
A contração de polimerização das resinas compostas é uma característica indesejável que compromete a integridade da interface dente/restauração. O objetivo deste estudo foi avaliar in vitro a influência de diferentes materiais usados em restaurações classe II de resina composta, quanto ao grau de conversão, tensão de contração, resistência a flexão, módulo de elasticidade e formação de fenda marginal. Foram realizados preparos classe II com dimensões de 4x4x2mm em terceiros molares recém-extraídos para a avaliação da formação de fenda marginal. As cavidades foram niveladas com cimento de ionômero de vidro Riva Light Cure (SDI) (CIV), resina de baixa contração SureFilSDR (Dentsply) (SDR), resina flow FiltekZ350Flow (3M/ESPE) (Z350F) e resina composta FiltekP90 (3M/ESPE) (P90). As restaurações (n=3) foram avaliadas com lupa estereoscópica. A resistência a flexão foi avaliada por meio de ensaio de flexão em três pontos. Para este ensaio foram confeccionados dez corpos de prova (n=10) de cada material com dimensões de 10x2x1mm. Para o teste de tensão de contração foram utilizados cilindros de polimetacrilato com 5 mm de diâmetro e 13 ou 28mm de comprimento. Os bastões foram fixados na EMIC com um espaço de 2mm entre eles, onde os materiais foram inseridos. Foram realizadas cinco repetições para cada grupo (n=5) e a tensão proveniente da contração foi medida por até 10 minutos após o início da fotopolimerização. O Grau de Conversão (GC) foi determinado por espectroscopia no infravermelho com transformada de Fourier (FTIR). Os resultados foram tratados estatisticamente por análise de variância (ANOVA) e Teste de Tukey (p<0,05). Fenda marginal: Z350F = CIV > SDR = P90. Tensão de contração: Z350F > SDR > CIV = P90. Resistência a flexão: P90 > SDR = Z350F > CIV. Módulo de Elasticidade: P90 > CIV = SDR = Z350F. GC: Z350F = SDR > P90 > CIV. Conclusões: existe correlação entre a formação de fenda marginal e as propriedades físico químicas dos materiais testados, sendo as resinas de baixa contração que proporcionaram melhor adaptação marginal; existe correlação entre resistência a flexão, módulo de elasticidade, tensão de contração e a composição dos materiais, já que os compósitos com melhores resultados foram os que apresentaram os maiores percentuais de carga, no entanto, maior grau de conversão não representou melhores propriedades mecânicas. / The shrinkage of composite resin polymerization is an undesirable characteristic that compromises the integrity of the tooth / restoration interface. The aim of this study was to evaluate in vitro the influence of different materials used in composite resin class II restorations in terms of contraction stress, flexural strength, degree of conversion and marginal gap formation. Class II preparation were performed with 4x4x2mm dimensions in third molars freshly extracted for the evaliation of marginal gap formation. The cavities were filled with Riva Light Cure (SDI) glass ionomer cement (CIV), SureFil SDR (Dentsply) low shrinkage resin (SDR), Filtek Z350Flow (3M/ESPE) flowable composite (Z350F) and Filtek P90 (3M/ESPE) composite resin (P90). The restorations (n = 3) were evaluated with magnifying stereoscopic. The flexural strength was assessed by means of three point bending test. For this test ten specimens (n = 10) of each material were made, each with 10x2x1mm dimensions. For the shrinkage stress test polymethacrylate cylinders with 5 mm in diameter and 13 or 28mm in length were used. Bats were attached to the EMIC with a 2mm space between them, where the materials were inserted. The test were repeated five times for each group (n = 5) and the contraction stress was measured for up to 10 minutes after initiation of photopolymerization. The Degree of Conversion (DC) was determined by Fourier transform infrared (FTIR). The results were statistically analyzed by the variance analysis (ANOVA) and Tukey test (p <0.05). Marginal gap: Z350F = CIV > SDR = P90. Contraction stress: Z350F > SDR> CIV = P90. Flexural strength: P90 > SDR = Z350F > CIV. Elasticity Modulus: P90 > CIV = SDR = Z350F. DC: Z350F = SDR > P90 > CIV. Conclusion: There is a correlation between formation of marginal gap and physicochemical properties of the materials tested whereas low shrinkage resins provided better marginal adaptation; correlation exists between flexural strength, elastic modulus, shrinkage stress and material composition, since better results were obtained from composites with larger quantity of load; higher conversion degree did not represent better mechanical properties.
55

Efeito da contaminação por saliva humana na interface adesiva: resistência de união, análise de camada híbrida e conversão de sistemas adesivos / Effect of human saliva contamination on adhesive interface: bond strength, hybrid layer analysis and conversion of adhesive systems

Carlos Andres Villavicencio Espinoza 03 July 2017 (has links)
Este estudo teve como objetivo analisar o efeito da contaminação por saliva humana na resistência de união (RU) da interface adesiva em dentina por microtração, nas características morfológicas da camada híbrida (CH) em microscopia confocal e no grau de conversão (GC) de 2 sistemas adesivos: Adper Single bond 2 (SB) e Single Bond® Universal (SU). Cento e oitenta dentes terceiros humanos hígidos foram divididos em 12 grupos (n=10), de acordo com o sistema adesivo utilizado, a presença de saliva e o tempo de armazenagem. Após o procedimento adesivo e aplicação da resina composta Filtek Z250, os dentes foram mantidos em água destilada em estufa a 37°C por 48 horas, 6 meses ou 12 meses antes de serem seccionados em palitos (0,8mm x 0,8mm, aproximadamente) para serem levados à máquina de ensaios universal Instron para os testes de microtração. Para à análise da interface adesiva em microscopia confocal de varredura a laser para verificação e mensuração de alterações internas na interface foram utilizados 60 dentes divididos em 6 grupos (n=10) de acordo com os tempos de 48 horas, 6 meses, e 12 meses respectivamente, empregando os sistemas adesivos (SB) e (SU). O efeito da presença de saliva também foi avaliado pelo grau de conversão dos adesivos, empregando-se espectroscopia de infravermelho transformada de Fourier empregando os sistema adesivos (SB) e (SU) com incorporação de saliva humana na sua composição (n=5) com concentrações 10%, 25% e 50% em vol. Para a comparação das variáveis: RU, (GC), espessura da CH, na presença de saliva e tempo de armazenamento foram utilizados os testes de Análise de Variância a três critérios e de comparações múltiplas de Tukey (p<0,05). Os valores de RU (MPa±dp: 48horas/6meses/1ano) foram: SB (43,53 ±6,0; 40,10±3,4; 38,59±5,4); SalSB (43,09±6,2; 39,86±6,6; 37,255,8); SU (42,98±4,3; 39,30±3,6; 40,44±5,7); Sal SU (44,39±4,2; 42,26±2,5; 38,26±5,7). Os Valores médios da CH (MPa±dp: 48horas/6meses/1ano) foram: SalSB (3,59±0,8; 3,59±1,0; 2,08±1,5). SalSU (1,26±0,5; 1,73±0,8; 1,07±0,3). Os valores de GC (MPa±dp: 10%/25%/50%vol) foram: SB (85,59±3,4; 49,68±12,8; 38,56±11,8); SU (85,52±3,3; 86,27±3,5; 57,82±11,1).Conclui-se, portanto, que a contaminação por saliva humana não interferiu na RU da interface dentina/resina composta após 48 horas, 6 meses e 12 meses. A morfologia da camada hibrida foi alterada pela presença da saliva nos períodos 6 e 12 meses,. O GC dos sistemas adesivos foi afetado pela presença de saliva após a polimerização imediata. Entretanto o fator tempo foi determinante para a deformação da interface dentina/resina para ambos os sistemas adesivos. / The objective of this study was to analyze the effect of human saliva contamination on bond strength of the dentin/adhesive interface, morphology of the hybrid layer by confocal microscopy and SEM analysis and degree of conversion of 2 adhesive systems: Adper Single bond 2 (SB) and Single Bond® Universal ( SU). One hundred and eighty healthy human third teeth were divided into 12 groups (n = 10), according to the adhesive system used, the presence of saliva and the storage time. After the adhesive procedure and placement of resin composite (Filtek Z250), the teeth were stored in distilled waterat 37 ° C for 48 hours, 6 months or 12 months before being cut into sticks (0.8mm x 0.8mm, approximately) to the microtensile strength tests. For the analysis of the adhesive interface in confocal microscopy of laser scanning for verification and measurement of internal interface changes, 60 teeth were used divided into 6 groups (n = 10) according to the storage time: 48 hours, 6 months, and 12 monthsand (SB) and (SU). The effect of the presence of saliva was also evaluated by the degree of conversion of the adhesives using Fourier transform infrared spectroscopy employing adhesive (SB) and (SU) systems incorporating human saliva in its composition (n = 5) with 10%, 25% and 50% vol. For the comparison of the variables: bond strength, degree of conversion, and hybrid layer thickness in the presence of saliva and storage time, the three criteria Variance Analysis and Tukey multiple comparisons tests (p <0.05) were used. The values of bond strength (MPa ± dp: 48hours / 6meses / year) were: SB (43.53 ± 6.0, 40.10 ± 3.4, 38.59 ± 5.4); SalSB (43.09 ± 6.2, 39.86 ± 6.6, 37.255.8); SU (42.98 ± 4.3, 39.30 ± 3.6, 40.44 ± 5.7); SU salt (44.39 ± 4.2, 42.26 ± 2.5, 38.26 ± 5.7). The mean values of hybrid layer thickness (MPa ± dp: 48hours / 6meses / year) were: SalSB (3.59 ± 0.8, 3.59 ± 1.0, 2.08 ± 1.5). SalSU (1.26 ± 0.5, 1.73 ± 0.8, 1.07 ± 0.3). The values of degree of conversion (MPa ± dp: 10% / 25% / 50% vol) were: SB (85.59 ± 3.4, 49.68 ± 12.8, 38.56 ± 11.8); (85.52 ± 3.3, 86.27 ± 3.5, 57.82 ± 11.1). It was therefore concluded that human saliva contamination did not interfere on bond strength of the dentin/adhesive interface after 48 hours, 6 months and 12 months. The morphology of the hybrid layer was altered by the presence of saliva after 6 and 12 months. The degree of conversion of adhesive systems was affected by the presence of saliva immediately after polymerization. However, the time factor was determinant for the dentine/resin interface deformation for both adhesive systems.
56

Efeito do pré-aquecimento e da pós-polimerização nas propriedades mecânicas e grau de conversão de um compósito experimental reforçado com fibra de vidro / Effect of pre-heating and post-curing on mechanical properties and degree of conversion of an experimental composite reinforced with glass fiber

Almeida, Letícia Nunes de 25 February 2016 (has links)
Submitted by Marlene Santos (marlene.bc.ufg@gmail.com) on 2016-09-21T13:42:33Z No. of bitstreams: 2 Dissertação - Letícia Nunes de Almeida - 2016.pdf: 4956536 bytes, checksum: ff3b7edcf1cb8b45c40f2292cb032676 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2016-09-21T13:45:21Z (GMT) No. of bitstreams: 2 Dissertação - Letícia Nunes de Almeida - 2016.pdf: 4956536 bytes, checksum: ff3b7edcf1cb8b45c40f2292cb032676 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2016-09-21T13:45:21Z (GMT). No. of bitstreams: 2 Dissertação - Letícia Nunes de Almeida - 2016.pdf: 4956536 bytes, checksum: ff3b7edcf1cb8b45c40f2292cb032676 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2016-02-25 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The pre-heating and post-curing can improve the mechanical properties of composites, even though there be no studies of fiber reinforced composites. The aim of this study was to evaluate the effect of pre-heating and post-curing autoclave and microwave in flexural strength (FS), diametral tensile strength (DTS), knoop microhardness (KHN) and degree of conversion (DC) of a experimental fiber- reinfoced composite. The experimental material was prepared with 30% glass fibers (3 mm), 22.5% of the resin matrix (40/60 Bis-GMA / TEGDMA) and 47.5% barium silicate particles. Six experimental groups were created by the interaction between the factors under study: heating, on two levels (without heating and heating at 60°C) and post-curing in 3 levels (conventional curing without post-curing, autoclave (120°C for 15 minutes) and microwaves (540 W for 5 minutes) The groups were: F - curing at 1500 mW/cm2 for 40 seconds; F + M - curing and post- polymerization in microwave; F + A - curing and post-curing in an autoclave , AQ + F - the composite heating prior to curing, AQ + F + M - heating prior to curing and post-curing in microwave;. AQ + F + A - heating prior to curing and post-curing and autoclave heating was conducted digital oven for 5 minutes at 60°C. Ten samples of the RF dimensions 25 x 2 x 2 mm and DTS in dimensions of 3 x 6 mm were tested in a universal testing machine Instron 5965, 0.5 mm/min. the KHN test was performed on samples of 3 x 6 mm with a load of 50 g for 30 sec, totaling 50 indentations per group. GC was obtained by Spectroscopy Fourier Transform Infrared (FTIR) on 5 samples. Data were analyzed by a factorial 2x3 and general linear model ANOVA and Tukey tests (α = 0.05). Factor analysis showed significant interaction between the factors just for RTD (p = 0.0001); preheating was significant factor for RF (p = 0.0001), RTD (p = 0.020) and KHN (p = 0.0001); post-curing factor for KHN was significant (p = 0.0001). ANOVA and Tukey tests showed statistically significant differences between groups for DTS (p = 0.001: AQ + F ≥ AQ + F + M = F + A = AQ + F + A = F + M ≥ F), FS (p = 0.016: AQ + F + M ≥ AQ + F + A + F = AQ = AQ + A + M ≥ F ≥ F) and KHN (p = 0.0001: AQ + F + M ≥ AQ + A + F = F = F + A + M ≥ F ≥ M + AQ). GC results showed no statistically significant difference. Through the Pearson correlation coefficient was observed significant positive correlation between the GC and RTD (r = 0.473, p = 0.008) and between DTS and FS (r = 0.263, p = 0.042). The pre-heating and post- polymerization were shown to be favorable to promote better mechanical properties of fiber reinforced composite by studied, specific for each property being analyzed. / O aquecimento prévio à polimerização e a pós-polimerização podem melhorar propriedades mecânicas em compósitos, embora inexistam estudos em compósitos reforçados com fibra. O objetivo deste estudo foi avaliar o efeito do pré- aquecimento e da pós-polimerização em autoclave e microondas na resistência flexural (RF), resistência à tração diametral (RTD), microdureza knoop (KHN) e grau de conversão (GC) de um compósito experimental reforçado por fibra de vidro. O material experimental foi confeccionado com 30% de fibras de vidro (3 mm), 22,5% de matriz resinosa (40/60 Bis-GMA/TEGDMA) e 47,5% de partículas de silicato de bário. Seis grupos experimentais foram criados pela interação entre os fatores em estudo: aquecimento, em dois níveis (controle sem aquecimento e aquecimento a 60oC) e pós-polimerização, em 3 níveis (fotopolimerização convencional sem pós- polimerização, autoclave (120oC por 15 minutos) e microondas (540 W por 5 minutos). Os grupos foram: F - fotopolimerização à 1500 mW/cm2 por 40 segundos; F+M - fotopolimerização e pós- polimerização em microondas; F+A - fotopolimerizacão e pós-polimerização em autoclave; AQ+F - aquecimento do compósito previamente à fotopolimerização; AQ+F+M - aquecimento previamente à fotopolimerização e pós-polimerização em microondas; AQ+F+A - aquecimento previamente à fotopolimerização e pós-polimerização e autoclave. O aquecimento foi realizado em estufa digital por 5 minutos a 60oC. Dez amostras de RF nas dimensões de 25 x 2 x 2 mm e de RTD nas dimensões de 3 x 6 mm foram testadas em máquina de ensaio universal Instron 5965, a 0,5mm/min. O teste de KHN foi realizado em amostras de 3 x 6 mm com carga de 50 g por 30 s, totalizando 50 indentações por grupo. O GC foi obtido através de Espectroscopia de Infravermelho por Transformada de Fourrier (FTIR) em cinco amostras. Os dados foram analisados por um modelo linear geral fatorial 2x3 e testes de ANOVA e Tukey (α=0,05). A análise fatorial mostrou interação significativa entre os fatores apenas para RTD (p=0,0001); o fator pré-aquecimento foi significante para RF (p=0,0001), RTD (p=0,020) e KHN (p=0,0001); o fator pós-polimerização foi significante para KHN (p=0,0001). Os testes de ANOVA e Tukey mostraram diferença estatística entre os grupos para RTD (p = 0,001: AQ+F ≥ AQ+F+M = F+A = AQ+F+A = F+M ≥ F), RF (p = 0,016: AQ+F+M ≥ AQ+F+A = AQ+F = AQ+A ≥ F+M ≥ F) e KHN (p = 0,0001: AQ+F+M ≥ AQ+F+A = F+A= F+M ≥ AQ+F ≥ F). Os resultados de GC não apresentaram diferença estatisticamente significante. Através do coeficiente de correlação de Pearson foi possível observar correlação positiva significante entre o GC e RTD (r = 0,473, p = 0,008) e entre RTD e RF (r = 0,263, p = 0,042) . O pré- aquecimento e a pós-polimerização mostraram-se favoráveis para promover melhores propriedades mecânicas do compósito reforçado por fibra estudado, sendo específicos para cada propriedade analisada.
57

Influência da composição da matriz orgânica, conteúdo inorgânico e tratamento térmico sobre diferentes propriedades de compósitos experimentais / Influence of composition of the organic matrix, filler content and thermic treatment on different properties of experimental composites

Renata Antunes Esteves 18 October 2013 (has links)
Objetivo: Analisar a influência da matriz orgânica, do conteúdo inorgânico e do tratamento térmico (TT) sobre diferentes propriedades de compósitos experimentais, tais como o grau de conversão (GC), tenacidade à fratura (KIC), resistência à flexão (RF) e módulo de elasticidade (ME). Métodos: Para o experimento foram analisadas seis formulações de compósitos experimentais com proporções molares de Bis-GMA:TEGDMA de 5:5 e 7:3, a carga utilizada foi o vidro de bário, nas concentrações de 30, 50 e 70% em peso, e os fotoiniciadores a amina e canforoquinona. O GC foi analisado através da espectroscopia no infra-vermelho (FTIR) (n=5). A KlC foi avaliada pelo método single-edge notched beam (SENB). As imagens das superfícies de fratura foram capturadas por um estereomicroscópio e a KlC calculada (n=10). A análise da RF e ME foi realizada através do teste dos três pontos (n=10). Para todos os fatores de variação estudados, metade dos espécimes imediatamente após à confecção receberam TT em estufa convencional, a 170º C por 10 minutos e a outra metade não. Após 24 horas, as amostras foram destinadas de acordo com os ensaios realizados. Os dados foram analisados utilizando ANOVA/Tukey para o grau de conversão, tenacidade à fratura e resistência à flexão, e, Kruskal-Wallis para o módulo de elasticidade (=5%). Resultados: Na análise do GC (%) foi observada significância estatística para os três fatores de variação analisados individualmente (monômero, carga e TT), como também, para a interação monômero x TT (p<0,001). Para a KIC e RF, as alterações significantes foram observadas apenas nos três fatores de variação (monômero, carga e TT) analisados individualmente (p<0,001). Para o ME, os fatores individuais (monômero, carga e TT), a interação carga x TT apresentaram significância estatística (p<0,001), bem como a interação monômero x carga (p=0,001). Conclusões: A matriz orgânica e o conteúdo inorgânico dos compósitos experimentais influenciaram o GC, a KIC, a RF e ME, e o TT promoveu melhorias nas propriedades estudadas. / Objective: To analyze the influence of organic matrix, the inorganic content and thermic treatment (TT) on different properties of experimental composites, such as the degree of conversion (DC), fracture toughness (KIC), flexural strength (FS) and elastic modulus (EM). Methods: This experiment analyzed six formulations of experimental composites with 5:5 and 7:3 molar proportions of Bis-GMA: TEGDMA. The load used was barium glass at concentrations of 30, 50 and 70% by weight and the photoinitiators, camphorquinone and amine. GC was analyzed by infrared spectroscopy (FTIR) (n=5). The KIC was evaluated by a \"single-edge notched beam\" (SENB). The images of the fracture surfaces were captured by a stereomicroscope and KIC calculated (n=10). The analysis FS and EM were performed by testing three points (n=10). For all the variation factors studied, half of the specimens immediately after the preparation received TT in conventional oven at 170º C for 10 minutes and the other half not. After 24 hours, the samples were designed according to the tests. Data were analyzed using ANOVA/Tukey the degree of conversion, fracture toughness and flexural strength, and Kruskal-Wallis test for the elastic modulus (=5%). Results: Analysis of GC (%) statistical significance was observed for the three variation factors analyzed individually (monomer, filler and TT), as well as for the interaction monomer x TT (p <0.001). For KIC and FS, significant changes were observed only in the three variation factors (monomer, filler and TT) analyzed individually (p<0.001). For EM, the individual factors (monomer, filler and TT) TT x filler interaction showed statistical significance (p <0.001), as well as the monomer x filler interaction (p = 0.001). Conclusions: The organic matrix and inorganic content of experimental composites influenced the GC, KIC, FS and EM, and the TT caused improvements in the properties studied.
58

Estudo de propriedades de resinas compostas bulk fill / Study of properties of bulk-fill resin composites

Ezequias Costa Rodrigues Júnior 20 January 2016 (has links)
Diante da evolução da composição das resinas compostas e do lançamento de compósitos do tipo bulk fill, faz-se necessário o estudo do desempenho dessa nova classe de materiais. Para isso, o presente estudo teve como objetivo avaliar propriedades como grau de conversão (GC) , dureza Knoop (KHN), resistência à flexão (RF) e tenacidade à fratura (KIC) de sete compósitos bulk fill (EverX Posterior, EXP; Filtek Bulk Fill Flow, FBFF; Fill-Up!, FU; SonicFill, SF; Surefil SDR, SDR; Tetric EvoCeram Bulk Fill, TECBF; Venus Bulk Fill, VBF) e um compósito nanohíbrido convencional (Charisma Diamond, CD). De forma complementar, foi realizado tratamento térmico a 170 °C por 10 minutos para melhor compreensão do comportamento desses materiais quanto ao potencial de conversão e à indução de tensões na interface carga/matriz. A avaliação do GC (n=3) foi realizada através de espectroscopia FTIR, a leitura da dureza Knoop foi realizada nas superfícies do topo e da base (n=3), e os ensaios de RF de três pontos (n=10) e KIC (n=10) em máquina de ensaios universais. Os resultados obtidos foram submetidos à analise de variância (complementados pelo teste de Tukey) ou teste Kruskal-Wallis, com nível de significância de 5%. A análise do GC (%) revelou diferença entre os materiais testados, sendo que todas as resinas bulk fill apresentaram valores maiores que a resina convencional: SF (75,7) > VBF (66,7) = EXP (66,4) = SDR (62,8), sendo esta também semelhante a FU (60,0); FU, TECBF (56,6), FBFF (56,6) e CD (54,5) apresentaram conversão semelhante. Os valores de KHN variaram de acordo com o material e com a superfície: apenas SF apresentou KHN semelhante (na superfície do topo) a CD, entretanto não foi possível realizar a leitura da superfície da base deste último material; SF, TECBF e FBFF apresentaram valores de KHN diferentes nas superfícies topo e base; EXP, FU, SDR e VBF mantiveram os valores de dureza do topo semelhantes à superfície da base. Para a RF (MPa), os resultados variaram de acordo com o material: EXP (122,54) = SF (101,09) = CD (99,15), sendo estes dois últimos semelhantes a FU (83,86) e TECBF (82,71), os quais não diferiram da resina SDR (65,18); esta última também mostrou comportamento semelhante a FBFF (60,85) e VBF (59,90). Quanto ao KIC (MPa.mm0,5), EXP (3,35) apresentou o maior valor, semelhante a SF (2,42), que por sua vez também foi igual ao compósito convencional CD (2,01); CD apresentou KIC semelhante a SDR (1,74); SDR = VBF (1,59) = TECBF (1,57); TECBF, FU (1,54) e FBFF (1,37) apresentaram valores semelhantes. Na dependência do material, o tratamento térmico aumentou os valores dos parâmetros estudados, apontando limitações da reação de polimerização dos compósitos estudados. Com base nos resultados obtidos, podese concluir que: resinas bulk fill apresentam elevado GC, superior à resina convencional estudada; a nova classe de materiais restauradores é capaz de polimerizar em profundidade e alguns materiais apresentam KHN semelhantes no topo e na base de espécimes de 4 mm de profundidade; RF e KIC variaram de acordo com o material, e o compósito EXP apresentou os maiores valores para ambos os testes. / Facing the evolution of the resin composites and the release of the bulk-fill composite type, it is necessary to study the performance of this new class of materials. For this, the present study aimed to evaluate properties such as degree of conversion (DC), Knoop hardness (KHN), flexural strength (FS) and fracture toughness (KIC) of seven bulk-fill composites (EverX Posterior, EXP; Filtek Bulk Fill Flowable, FBFF; Fill-Up!, FU; SonicFill, SF; Surefil SDR, SDR; Tetric EvoCeram Bulk Fill, TECBF; Venus Bulk Fill, VBF) and a conventional nanohybrid composite (Charisma Diamond, CD). Complementarily, heat treatment was performed at 170 °C for 10 minutes for better understanding the behavior of these materials. Evaluation of DC (n=3) was performed by FTIR spectroscopy, the evaluation of Knoop hardness was made on the top and bottom surfaces (n=3), and three point bending test (n=10) and KIC (n=10) were evaluated on a universal testing machine. The results were submitted to analysis of variance (complemented by Tukey test) or Kruskal-Wallis test with 5% significance level. Analysis of DC (%) revealed differences between tested materials, and all bulk-fill resins had higher values than the conventional resin: SF (75.7) > VBF (66.7) = EXP (66.4) = SDR (62.8), which was also similar to FU (60.0); FU, TECBF (56.6), FBFF (56.6) and CD (54.4) showed similar conversion. KHN values showed variations according to the material and the surface: only SF showed a similar KHN (on the top surface) to CD, however it was not possible to read the bottom surface of this latter material; SF, TECBF and FBFF presented different KHN values on the top and bottom surfaces; EXP, FU, SDR and VBF maintained top and bottom similar hardness values. For FS (MPa), the results varied according to the material: EXP (122.54) = SF (101.09) = CD (99.15), the latter two being similar to FU (83.86) and TECBF (82.71), which did not differ from SDR resin (65.18); the latter showed similar behavior to FBFF (60.85) and VBF (59.90). As for KIC (MPa.mm0.5), EXP (3.35) had the highest value, similar to SF (2.42), which in turn was also equal to the conventional composite CD (2.01); CD presented KIC similar to SDR (1.74); SDR = VBF (1.59) = TECBF (1.57); TECBF, FU (1.54) and FBFF (1.37) were similar. Depending on the material, heat treatment increased the values of the parameters, pointing limitations of polymerization reaction of the studied composites. Based on these results, it can be concluded that: bulk fill resins have high DC, higher than the conventional resin studied; the new class of restorative materials is capable of polymerizing in depth and some materials exhibited similar KHN at the top and bottom surfaces of 4 mm depth specimens; FS and KIC varied according to the material, and the EXP composite showed the highest values for both tests.
59

"Avaliação in vitro e in vivo da resina composta pré-aquecida em relação à cinética de polimerização / In vitro and in vivo appraisal of pre-heated resin composite with relation to polymerization kinetics

Márcia Daronch 04 July 2005 (has links)
O objetivo do trabalho foi investigar múltiplos aspectos relacionados ao pré-aquecimento da resina composta anterior à fotoativação: o grau de conversão e a cinética da polimerização em função da temperatura de polimerização, tempo de fotoativação e profundidade; o desempenho da fonte aquecedora (temperatura máxima, estabilidade térmica do aparelho e variações de temperatura ao pré-aquecer compules) e aspectos clínicos (o efeito de ciclos de pré-aquecimento repetidos e prolongados sobre o grau de conversão, a variação da temperatura intrapulpar in vitro e a variação da temperatura in vivo ao usar resina composta pré-aquecida ou a temperatura ambiente. A conversão de monômeros e os parâmetros de cinética foram determinados através de FTIR-ATR. Os espécimes foram fotoativados por 5, 10, 20 ou 40s entre 3 o e 60 o C. Foram calculados o grau de conversão em tempo real, a taxa máxima de conversão, o tempo em que ocorreu a taxa máxima, e a conversão na taxa máxima. Os dados foram tratados por análise de variância, teste-t e análise de regressão (p &#8804;0,05). O desempenho do dispositivo aquecedor foi medido monitorando-se a mudança de temperatura em tempo real com o auxílio de um termopar tipo-k conectado a um conversor analógico-digital. Os termopares foram colocados no aquecedor e dentro de compules de compósito. Os dados foram analisados com teste t (p &#8804;0,05). Compules (n=5) foram submetidos a um dos ciclos térmicos: Pré-aquecimento repetido (da temperatura ambiente a 60 o C, por 10 vezes) ou Prolongado (24h a 60 o C). O grau de conversão foi medido 24h após os ciclos, com o compósito à temperatura ambiente, seguindo o protocolo descrito acima. Os dados foram tratados por análise de variância e teste de Tukey (p&#8804;0,05). O aumento da temperatura intrapulpar foi medido por um termopar colocado na câmara pulpar de um prémolar contendo uma cavidade de Classe V (com 1mm de espessura de dentina remanescente). O preparo foi preenchido com compósito à temperatura ambiente ou pré-aquecido enquanto a temperatura intrapulpar era continuamente monitorada (n=5). Os dados foram comparados por análise de variância e teste de Tukey (p &#8804;0,05). Para a medida da variação de temperatura in vivo, foram feitos preparos cavitários de 2mm de profundidade em dentes posteriores de um indivíduo (n=3). Uma sonda que mensurava a temperatura foi introduzida no dente preparado em cada procedimento restaurador e durante a inserção da resina composta à temperatura ambiente ou pré-aquecida a 60°C. Os dados foram comparados com análise de variância e teste de Tukey (p &#8804;0,05). Os resultados indicaram que: 1) o pré-aquecimento da resina composta anterior à fotoativação aumenta o grau de conversão, reduz o tempo de fotoativação e resulta em maior taxa de conversão, sem alterar o tempo em que a taxa máxima ocorre; 2) tanto o dispositivo aquecedor quanto os compules atingiram temperaturas inferiores das determinadas pelo fabricante; ao remover o compósito do aquecedor a perda de calor é acentuada ; 3) o grau de conversão não foi afetado por ciclos repetidos e prolongados de pré-aquecimento da resina composta; 4) não houve aumento da temperatura intrapulpar ao serem comparadas as resinas composta à temperatura ambiente e pré-aquecida; 5) a medida da temperatura in vivo revelou que o compósito pré-aquecido a 60 o C fica somente 8 o C acima da temperatura intrabucal; a técnica de pré-aquecimento deve ser usada com cautela. / This work examined multiple aspects of pre-heating dental resin composite prior to light-curing: the monomer conversion and polymerization kinetics as a function of cure temperature, light-exposure duration and depth; the performance of the heating device (maximum temperature, thermal stability of device and temperature change when pre-heating compules); and clinically relevant issues (the effect of repeated and extended pre-heating cycles on conversion; in vitro intrapulpal temperature change and in vivo temperature change when using either room-temperature or pre-heated composite). Monomer conversion and kinetic parameters were determined using FTIR-ATR. Specimens were cured for 5, 10, 20 or 40s between 3 o and 60 o C. Real-time monomer conversion, maximum conversion rate, time into exposure when maximum rate occurred, and conversion at maximum rate were calculated. Data were analyzed using regression analysis, Student's t-tests, and ANOVA with appropriate post-hoc tests (alpha = 0.05). Performance of the heating device was measured by monitoring the real-time temperature change with a K-type thermocouple connected to an analog-to-digital converter. Thermocouples were placed both in the heater and inside composite compules. Data were analyzed using Student t-test (alpha = 0.05). Compules (n=5) were submitted to one of the temperatures cycles: Repeated (from room temperature to 60 o C, 10 times) or Extended pre-heating (24h at 60 o C). Monomer conversion was measured 24h after cycling, with composite at room temperature, following the protocol described above. Data were analyzed using ANOVA and the Tukey-Kramer post-hoc test (alpha = 0.05). Intrapulpal temperature rise was measured by placing a K-type thermocouple in the pulp chamber of a extracted, human premolar, which had a Class V preparation (1mm remaining dentin thickness). The preparation was filled using composite either at room-temperature, or pre-heated while continuously monitoring intrapulpal temperature (n=5). Data were compared using ANOVA and the Tukey-Kramer post-hoc test (&#945; =0.05). For measurement of temperature change in vivo, 2mm deep preparations were made on posterior teeth of a live human subject (n=3). Temperature values were recorded by placing a custom-made probe on the tooth preparation after each restorative procedure and during insertion of resin-composite at room temperature or pre-heated to 60°C. Data were compared using a 2-way ANOVA, and Tukey-Kramer post-hoc test (&#945; =0.05). Results indicated that: 1) pre-warming composite prior to polymerization results in greater conversion, requires shorter exposure duration, and enhances maximal rate of conversion without changing the time into the exposure when the maximum rate occurs; 2) either the heating device or the compules achieved lower temperatures than those stated by the manufacturer; composite temperature loss upon removal from the heater was dramatic; 3) neither repeated nor extended pre-heating of composites significantly affected monomer conversion values; 4) no increase in intrapulpal temperature values was observed when comparing room temperature and pre-heated composite; 5) temperature measurement in vivo revealed that composite pre-heated to 60°C attains only 8 o C above intraoral temperature upon delivery; thus, the composite pre-heating technique should be used with caution.
60

Efeito do tipo de fonte de luz sobre propriedades físicas de cimentos resinosos experimentais contendo diferentes sistemas fotoiniciadores / Effect of light curing units on the physical properties of experimental resin cements containing different photoinitiators systems

Leonardo Freitas da Silveira 25 March 2013 (has links)
Cimentos resinosos experimentais contendo diferentes sistemas fotoiniciadores apresentaram propriedades físicas semelhantes ou superiores a cimentos resinosos convencionais sob efeito de diferentes tipos de fonte de luz. Objetivo: Analisar o espectro de diferentes fontes de luz e sistemas fotoiniciadores e sua influência nas propriedades físicas de cimentos resinosos quando ativados, através de um anteparo cerâmico, por fontes de luz halógena e LED. Metodologia: Cimentos resinosos experimentais contendo uma mistura de BisGMA, TEGDMA (50wt%) e partículas de carga silanizadas (65wt%), foram preparados com o uso dos fotoiniciadores Canforoquinona (CQ), Fenil Propanodiona (PPD) e Óxido bis-alquil fosfínico (BAPO) de forma isolada e combinados. Os co-iniciadores utilizados foram Difenil Iodônio (DFIHFP) e a amina terciária DMAEMA. As fontes de luz utilizadas foram: lâmpada halógena (XL 2500) e duas fontes de diodo emissor de luz - LED (FreeLigth 2 e Bluephase). Um anteparo cerâmico (IPS e.max Press) apresentando 13,0mm x 1,0mm de espessura foi utilizado durante os testes. Amostras com 7,0mm x 2,0mm x 1,0mm foram confeccionadas (n=360). A avaliação do Grau de Conversão (GC) dos cimentos experimentais foi realizada por Espectroscopia de Infravermelho Transformada de Fourier (FTIR), sendo em seguida submetidas ao teste de resistência à mini-flexão, módulo flexural e microdureza Knoop. Os resultados obtidos em todos os testes foram submetidos à análise de variância dois fatores - ANOVA e teste de Tukey (5%). Resultados: A associação do DFIHFP aos fotoiniciadores aumentou as propriedades avaliadas de todos os cimentos experimentais independente da fonte de luz (FL) utilizada. O fotoiniciador BAPO apresentou resultados superiores ou iguais estatisticamente em comparação ao grupo controle (CQ/amina), independente da FL utilizada. Conclusão: A utilização de sistemas iniciadores e co-iniciadores alternativos possibilita a obtenção de propriedades superiores ou iguais ao sistema convencional, tornando-se um sistema promissor para atuar de forma isolada ou associada. / Resin cements containing different experimental photoinitiators systems present physical properties similar to or better than conventional resin cements under the effect of different types of light source. Objective: To analyze the spectrum of different light sources and systems photoinitiators and their influence on physical properties of resin cements when activated through a bulkhead ceramic, halogen light sources and LED. Methodology: experimental resin cements containing a mixture of BisGMA, TEGDMA (50wt%) and silanized filler particles (65wt%) were prepared with the use of photoinitiators camphorquinone (CQ), phenyl oxide bis-propanedione (PPD) and alkyl phosphinic (BAPO) separately and combined. The primers used were co-diphenyl iodonium (DFIHFP) tertiary amine and DMAEMA. The light sources used were: halogen lamp (XL 2500) and two sources of light emitting diode - LED (FreeLigth bluephase and 2). A ceramic shield (IPS e.max Press) having 13.0mm x 1.0mm thick was used for testing. Samples with 7.0mm x 2.0mm x 1.0mm were fabricated (n=360). The evaluation of the degree of conversion (GC) of experimental cements was performed by Infrared Spectroscopy Fourier Transform, and then to test for resistance to mini-bending, flexural modulus and microhardness. The results in all tests were subjected to two-factor analysis of variance - ANOVA and Tukey test (5%). Results: The combination of photoinitiators DFIHFP to improve board properties of all the experimental cements independent light source (LCU) used. The photoinitiator BAPO showed statistically equal or better results compared to the control group (CQ / amine), regardless of LCU used. Conclusion: The use of systems co-initiators and initiators to obtain alternative provides equal or better properties to the conventional system, making it a promising system to act in isolation or in combination.

Page generated in 0.0924 seconds