41 |
Economic and environmental optimization of deep energy renovation strategies for an office building in SwedenSauterleute, Eva January 2022 (has links)
Energy efficiency of the building sector is a key strategy to achieve national climate goals in Sweden and other European countries. In this thesis, several renovation scenarios for a case study office building in Sweden are analysed and compared based on their energy performance, environmental impacts, and economic costs from a life cycle perspective. As a baseline, the case study building was simulated in IDA ICE and compared with the simulated renovation scenarios. For the Life Cycle Analysis (LCA) and the Life Cycle Costs (LCC), the commercially available software OneClickLCA was used. The renovation scenarios were carried out over three rounds: (i) material type scenarios where five insulation materials (glass wool, rock wool, hemp fiber, Expanded Polystyrene (EPS), and Extruded Polystyrene (XPS)) and two frame materials (wood and steel) are compared; (ii) insulation thickness optimization from economic and environmental performance perspectives (iii) comparison of combination with other typical renovation measures such as changing of windows, improving specific fan power, heat exchanger efficiencies, and lightings. The results show that glass wool gives the most economical and environmental performance, followed by rock wool and EPS. When considering other environmental indicators, hemp fiber presents the best environmental option. However, it is not competitive with traditional insulation materials from an economic perspective. The insulation thickness scenarios show different optimal economic and environmental performance points, giving total energy savings of 5 % and 9,5 %, respectively. When considering other typical energy efficiency measures, the highest impact on the energy performance was found when improving the specific fan power (SFP) and switching to LED lights with total electricity reductions (including user-based electricity consumption) of 4 % and 14 %, respectively. Conclusively, the case study showed how the electricity and heating demand of the studied office building could be reduced, and the environmental and economic consequences of the different energy-efficiency measures.
|
42 |
Green Anesthesia : Use of Inhalational Anesthetics and their Effect on our Climate / Miljövänlig Anestesi : Användning av inhalationsanestetika och dess påverkan på vårt klimatKarchut, Sabina, Wedahl, Skylar January 2023 (has links)
This thesis has, commissioned by Dräger, an international company at the forefront of medical and safety technology, examined how the use of inhalational anesthetics affects the climate and environment. The purpose of this work is to examine how the Swedish healthcare sector currently works with inhalational anesthetics, how different anesthetic machines affect the emissions, as well as alternatives available to reduce anesthetic gases emissions. Climate change is a current issue in today’s society, but the impact of anesthetic gases on the climate is not widely known, despite their everyday use in the healthcare sector. Through data collection from two Swedish hospitals; Linköping University Hospital and Örebro University Hospital, an interview with medical and medical engineering staff, as well as a literature study the main question of the thesis could be answered; How do the most common anesthetic gases affect the environment? The results are presented in the form of diagrams showing the amount of anesthetic gas used in the aforementioned hospitals during surgeries. The results have been analyzed and discussed based on the research questions, and the different results from each hospital have been compared to each other. It can be seen that Dräger’s anesthesia machines have a relatively low consumption of sevoflurane, but it is impossible to draw any definitive conclusions due to lack of data, and lack of access to machines from other manufacturers. / Detta examensarbete har, på uppdrag av Dräger, ett internationellt företag i framkant inom medicin- och säkerhetsteknik, undersökt hur användning av inhalationsanestetika påverkar miljön. Målet med arbetet är att undersöka hur den svenska sjukvården för närvarande arbetar med inhalationsanestetika, hur olika anestesimaskiner påverkar utsläppen, samt alternativ som finns tillgängliga för att minska dessa utsläpp. Klimatförändringar är en aktuell fråga i dagens samhälle men påverkan av anestesigaser på klimatet är inte allmänt känt, trots att dessa används dagligen i hälsovården. Genom datainsamling från två svenska sjukhus; Linköpings Universitetssjukhus och Örebro Universitetssjukhus, intervjuer med medicinsk- och medicinteknisk personal, samt en litteraturstudie har arbetets problemställning besvarats; Hur påverkar de mest frekvent använda anestesigaserna miljön? Resultaten visar i diagramform hur mycket anestesi gas som använts i tidigare nämnda sjukhus under operationer. Resultaten har analyserats och diskuterats utifrån forskningsfrågorna, dessutom har de olika resultaten från respektive sjukhus jämförts med varandra. Det kan ses att Drägers anestesimaskiner har en relativt låg konsumtion av sevofluran, men brist på data samt brist på tillgång till maskiner från andra producenter gör det omöjligt att dra en konkret slutsats.
|
43 |
[pt] MODELAGEM DE UM CIRCUITO DE TERMOSSIFÃO DE BAIXO IMPACTO AMBIENTAL COM APLICAÇÃO EM RESFRIAMENTO DE ELETRÔNICOS / [en] MODELING OF A TWO-PHASE THERMOSYPHON LOOP WITH LOW ENVIRONMENTAL IMPACT REFRIGERANT APPLIED TO ELECTRONIC COOLINGVERONICA DA ROCHA WEAVER 04 October 2021 (has links)
[pt] Diante dos constantes avanços da tecnologia os dispositivos eletrônicos vêm passando por um processo de miniaturização, ao mesmo tempo em que sustentam um aumento de potência. Essa tendência se mostra um desafio para seu gerenciamento térmico, uma vez que os sistemas de resfriamento típicos para eletrônicos utilizam ar como fluido de trabalho, e o seu baixo coeficiente de transferência de calor limita sua capacidade de atender às necessidades térmicas da indústria atual. Nesse sentido, o resfriamento bifásico tem sido considerado uma solução promissora para fornecer resfriamento adequado para dispositivos eletrônicos.
Circuitos de termossifão bifásico combinam a tecnologia de resfriamento bifásico com sua inerente natureza passiva, já que o sistema não requer uma bomba para fornecer circulação para seu fluido de trabalho, graças às forças da gravidade e de empuxo. Um dissipador de calor de microcanais, localizado bem em cima do dispositivo eletrônico, dissipa o calor gerado. Isto o torna uma solução de baixo custo e energia. Além disso, ter um circuito de termossifão operando com um refrigerante de baixo GWP, como o R-1234yf, resulta em baixo impacto para o meio ambiente, uma vez que é um refrigerante ecologicamente correto e o sistema tem baixo ou nenhum consumo de energia.
Este trabalho fornece um modelo numérico detalhado para a simulação de um circuito de termossifão bifásico, operando em condições de regime permanente. O circuito compreende um evaporador (chip e dissipador de calor de micro-aletas), um riser, um condensador refrigerado a água de tubo duplo e um downcomer. Equações fundamentais e constitutivas foram estabelecidas para cada componente. Um método numérico de diferenças finitas, 1-D para o escoamento do fluido por todos os componentes do sistema, e 2-D para a condução de calor no chip e evaporador foi empregado.
O modelo foi validado com dados experimentais para o refrigerante R134a, mostrando uma discrepância em relação ao fluxo de massa em torno de 6 por cento, para quando o sistema operava sob regime dominado pela gravidade. A pressão de entrada do evaporador prevista apresentou um erro relativo máximo de 4,8 por cento quando comparada aos resultados experimentais. Além disso, a maior discrepância da temperatura do chip foi inferior a 1 grau C.
Simulações foram realizadas para apresentar uma comparação de desempenho entre o R134a e seu substituto ecologicamente correto, R1234yf. Os resultados mostraram que quando o sistema operava com R134a, ele trabalhava com uma pressão de entrada no evaporador mais alta, assim como, com um fluxo de massa mais alto. Por causa disso, o R134a foi capaz de manter a temperatura do chip mais baixa do que o R1234yf. No entanto, essa diferença na temperatura do chip foi levemente inferior a 1 grau C, mostrando o R1234yf como comparável em desempenho ao R134a. Além disso, o fator de segurança da operação do sistema foi avaliado para ambos os refrigerantes, e para um fluxo de calor máximo do chip de 33,1 W/cm2, R1234yf mostrou um fator de segurança acima de 3. Isso significa que o circuito de termossifão pode operar com segurança abaixo do ponto crítico de fluxo de calor.
Dada a investigação sobre a comparação de desempenho dos refrigerantes R134a e R1234yf, os resultados apontaram o R1234yf como um excelente substituto ecologicamente correto para o R134a, para operação em um circuito de termossifão bifásico. / [en] Given the constant advances in technology, electronic devices have been going through a process of miniaturization while sustaining an increase in power. This trend proves to be a challenge for thermal management since commonly electronic cooling systems are air-based, so that the low heat transfer coefficient of air limits its capacity to keep up with the thermal needs of today s industry. In this respect, two-phase cooling has been regarded as a promising solution to provide adequate cooling for electronic devices.
Two-phase thermosyphon loops combine the technology of two-phase cooling with its inherent passive nature, as the system does not require a pump to provide circulation for its working fluid, thanks to gravity and buoyancy forces. A micro-channel heat sink located right on top of the electronic device dissipates the heat generated. This makes for an energy and cost-efficient solution. Moreover, having a thermosyphon loop operating with a low GWP refrigerant such as R-1234yf results in low impact for the environment since it is an environmentally friendly refrigerant, and the system has low to none energy consumption.
This work provides a detailed numerical model for the simulation of a two-phase thermosyphon loop operating under steady-state conditions. The loop comprises an evaporator (chip and micro-fin heat sink), a riser, a tube-in-tube water-cooled condenser and a downcomer. Fundamental and constitutive equations were established for each component. A finite-difference method, 1-D for the flow throughout the thermoysphon s components and 2-D for the heat conduction in the evaporator and chip, was employed. The model was validated against experimental data for refrigerant R134a, showing a mass flux discrepancy of around 6 percent for when the system operated under gravity dominant regime. The predicted evaporator inlet pressure showed a maximum relative error of 4.8 percent when compared to the experimental results. Also, the chip temperature s largest discrepancy was lower than 1 C degree.
Simulations were performed to present a performance comparison between R134a and its environmentally friendly substitute, R1234yf. Results showed that when the system operated with R134a, it yielded a higher evaporator inlet pressure as well as a higher mass flux. Because of that, R134a was able to keep the chip temperature lower than R1234yf. Yet, that difference in chip temperature was slightly lower than 1 C degree, showing R1234yf as comparable in performance to R134a. In addition, the safety factor of the system s operation was evaluated for both refrigerants, and for a maximum chip heat flux of 33.1 W/cm2, R1234yf showed a safety factor above 3. This means the thermosyphon loop can operate safely under the critical heat flux.
Given the investigation on the performance comparison of refrigerants R134a and R1234yf, results pointed to R1234yf being a great environmentally friendly substitute for R134a for the two-phase thermosyphon loop.
|
44 |
Global warming potential reduction by carbon dioxide utilization in the production of synthesis gas and its derivativesMedrano, Juan Diego 16 September 2019 (has links)
The indiscriminate emission of CO2 is drastically aggravating climate change. Carbon Capture and Utilization (CCU) was born as a complementary solution to this issue. This thesis studies the consumption of carbon dioxide in industrial processes, starting from synthesis gas, and using this building block in subsequent syntheses; ultimately integrating CO2 utilization with previously non-CO2 consuming processes.
|
45 |
Hampafiberns potential för en hållbar utveckling : En jämförande studie mellan hampafiberisolering och konventionella isoleringsmaterial ur ett livscykelperspektiv / The potential of hemp fibre insulation for a sustainable development : A comparative study between hemp fiber insulation and conventional insulation materials from a life cycle perspectiveSvedin, Daniel, Wennberg, David January 2021 (has links)
Världens fokus på hållbar utveckling är större än någonsin tidigare, och konstruktionssektorn ansvarar för upp emot 25 till 40 procent av de globala koldioxid emissionerna. Ett av nyckelmaterialen för att öka en byggnads energieffektivitet är isoleringsmaterialen. Syftet med detta kandidatexamensarbete är att utvärdera GWP:n av hampafiberisolering jämfört med de två marknadsledande isoleringsmaterialen, mineralull och cellplast. GWP:n av de tre isoleringsmaterialen beräknas efter att vardera isoleringsmaterial har blivit placerat i ett envåningshus med storleken 30 m2. Livscykelanalysen för byggnader används sedan som bakgrund för att beräkna GWP:n av de tre byggnaderna. De beräknade kategorierna för GWP:n av byggnaderna är: råmaterial, transport, produktion, konstruktion samt energianvändningen. Byggnaderna antas ha en inomhustemperatur på 20°C och har blivit konstruerade i Stockholm, Sverige. Utan överraskning var hampafibern det isoleringsmaterial som hade lägst GWP i kategorierna; råmaterial, produktion och konstruktion. Däremot på grund av hampafiberns mindre optimala termiska konduktivitet jämfört med de andra isoleringsmaterialen var byggnaden med hampafiberisolering den minst energieffektiva. Trots den lägre energieffektiviteten visade sig byggnaden med hampafiberisolering vara den med lägst GWP under en 30 årsperiod, förutsatt att förnyelsebara energikällor användes. Överraskande nog, var däremot källan från vart elektriciteten kom mycket viktig för att avgöra byggnadernas GWP. När den svenska elmixen från Boverkets klimatdatabas användes var skillnaden i GWP mellan de olika byggnaderna marginell. Användes istället förnyelsebara energikällor i form av vindkraft, var hampafiberisoleringen det mest fördelaktiga isoleringsmaterialet ur ett miljöperspektiv. / The world's focus on global warming has grown larger than ever before, and the construction sectorisresponsibleforupwardsof 25to40percentoftheglobalcarbonemissions.Oneof the key materials to increase the energy efficiency of buildings are insulation materials. The purpose of the thesis is to evaluate the global warming potential of insulation made out of hemp compared with the two leading insulation materials on the global market, Mineral wool insulation & EPS. The global warming potential of the three insulation materials are calculated whilst each is placed in a 30 m2 one-story house. The life cycle assessment (LCA) of buildings is used as background to calculate the global warming potential of each of the three buildings. The calculated categories for the global warming potential are: raw materials, transportation, production, the construction phase, and energy usage in the building. The buildings are assumed to have an inside temperature of 20°C and have been constructed in Stockholm, Sweden. To no surprise the hemp fibre insulation material had the lowest global warming potential out of the three materials during the raw material, production and construction phase. However due to the less optimal value of thermal conductivity for the hemp fiber insulation compared to the other materials, the energy efficiency in the building using hemp fibre insulation was comparatively the worst. However, the building using hemp fibre insulation could be concluded as the one with the least global warming potential during a 30 year usage if the correct energy sources were used. Surprisingly enough it turned out that the source of electricity was vital for the global warming potential. When using the Swedish electricity mix found in Boverkets Climate database the difference between the buildings was marginal. If renewable sources in the form of wind power were used instead of the national mix for electricity the differences were more noticable and the building using hemp fiber as insulation was less impactful the lower the global warming potential of the energy source was per kWh.
|
Page generated in 0.0489 seconds