• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 135
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 135
  • 120
  • 64
  • 64
  • 52
  • 47
  • 35
  • 35
  • 35
  • 34
  • 33
  • 25
  • 24
  • 24
  • 23
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Análise do comportamento de ferramentas de corte com diferentes revestimentos e seu efeito sobre a geração de calor no osso / Alexsander Luiz Golin ; orientadora, Karin Soldatelli Borsato ; co-orientador, Ricardo Diego Torres

Golin, Alexsander Luiz January 2005 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2005 / Inclui bibliografia / Com o desenvolvimento de novas tecnologias nas áreas da bioengenharia, a ampliação dos conhecimentos voltados para novos materiais e novos processos tem sido bastante necessária. Para qualquer aplicação de determinado biomaterial, seja ele implantado ou t
112

Avaliação das variações da transferência do planejamento virtual e sobre protótipos biomédicos para a instalação de implantes dentários pela técnica cirúrgica guiada

Viegas, Vinicius Nery January 2008 (has links)
Made available in DSpace on 2011-12-27T14:14:02Z (GMT). No. of bitstreams: 2 000408028-0.pdf: 4863155 bytes, checksum: 1ba85f4de0b0a48ac9f7e911d06bf512 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / Guided surgery in Implant Dentistry consists of stages that comprise image diagnosis, virtual planning, bioprototyping and surgical application. The aim of this research was to evaluate the variations in the transfer of virtual planning and over biomedical prototypes for the procedure of dental implant placement by means of this technique. The experiment was conducted on 11 identical replicas of the human edentulous mandible. Definition of the implant positions was standardized and performed with specific software, from pre-operative cone beam computerized tomography images. For each of the mandibles, biomodels and surgical guides were made by the stereolithographic method. Initially simulated surgeries were performed with placement and removal of implants in the prototypes. After this, the implants were placed in the replicas of the mandible. To analyze the results, post-operative tomographs were performed and standardized cuts obtained on the prototypes and in the replicas, which enabled the implant beds to be visualized. Superimposition of the tridimensional pre and post-operative models allowed evaluation of the linear distance and angle formed by the long axes of the implants that had been planned and obtained. Linear measurements made directly on the models were used to evaluate the validity of procedures simulated in prototypes in the planning stage in Implant dentistry. The variations of distances between the coronal, central and apical regions of the 22 implants evaluated in this research presented mean values lower than 0. 41 mm.As regards angulation, the implants placed on the right side of the replicas presented variations of 1. 45 ± 0. 89 degrees, and those on the left side, 0. 70 ± 0. 30 degrees. Application of the Student’s-t test to compare the samples with a reference value zero indicated statistically significant difference for all the measurements analyzed (p<0. 05). The correlation between the positions of the implant beds in each mandible presented values considered from reasonable to very good, according to the distance analyzed and the method of interpretation used According to results of this study, the variations found in the transference to the operative field of dental implant positioning, determined during virtual planning and obtained in surgeries simulated with biomedical prototypes, confirm the reliability of guided surgery techniques in implantology. The safety margin of the method, considering the variation in the position of the implants and the overestimation or underestimation of the measurements in procedures simulated on biomodels, must be better evaluated in clinical studies. / A cirurgia guiada em Implantodontia consta de etapas que integram diagnóstico por imagem, planejamento virtual, bioprototipagem e aplicação cirúrgica. O objetivo desta pesquisa foi avaliar as variações na transferência do planejamento virtual e sobre protótipos biomédicos para o procedimento de instalação de implantes dentários por meio desta técnica. O experimento foi realizado em 11 réplicas idênticas de mandíbula humana edêntula. A definição do posicionamento dos implantes foi padronizada e realizada em software específico, a partir de imagens de tomografias computadorizadas cone-beam pré-operatórias. Para cada uma das mandíbulas, foram confeccionados biomodelos e guias cirúrgicos pelo método de estereolitografia. Inicialmente, foram realizadas cirurgias simuladas com a colocação e remoção dos implantes nos protótipos. Em seguida, os implantes foram instalados nas réplicas de mandíbula. Para análise dos resultados, foram realizadas tomografias pós-operatórias e obtidos cortes padronizados nos protótipos e nas réplicas, que possibilitaram a visualização dos leitos dos implantes. A sobreposição dos modelos tridimensionais pré e pós-operatórios permitiu a avaliação da distância linear e do ângulo formado pelos longo-eixos dos implantes planejados e executados. Medidas lineares realizadas diretamente sobre os modelos foram utilizadas para avaliar a validade de procedimentos simulados em protótipos na fase de planejamento em Implantodontia. As variações das distâncias entre as regiões coronais, centrais e apicais dos 22 implantes avaliados nesta pesquisa apresentaram valores médios inferiores à 0,41 mm.Quanto à angulação, os implantes instalados no lado direito das réplicas apresentaram variações de 1,45 ± 0,89 graus e os do lado esquerdo, de 0,70 ± 0,30 graus. A aplicação do teste t de Student, para comparar as amostras com um valor de referência zero, indicou diferença estatisticamente significativa para todas as medidas analisadas (p<0,05). A correlação entre o posicionamento dos leitos dos implantes, em cada mandíbula, apresentou valores considerados razoáveis a muito bons, de acordo com a distância analisada e o método de interpretação utilizado. De acordo com os resultados desta pesquisa, as variações observadas na transferência para o campo operatório do posicionamento de implantes dentários, determinado durante o planejamento virtual e obtido em cirurgia simulada sobre protótipo biomédico, indicam a confiabilidade da utilização da técnica de cirurgia guiada em Implantodontia. A margem de segurança do método, considerando a variação na posição dos implantes e a superestimação ou subestimação de medidas em procedimentos simulados em biomodelos, deve ser melhor avaliada em estudos clínicos.
113

Avaliação da ação do laser (AsGaAl) no torque de remoção de implantes lisos e texturizados

Meyer, Kleber Ricardo Monteiro January 2008 (has links)
Made available in DSpace on 2011-12-27T14:14:09Z (GMT). No. of bitstreams: 2 000408029-0.pdf: 5297005 bytes, checksum: b759a1194fe1debd841abcedaff116d7 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / This work evaluated the laser (AsGaAl) laser effect by torque removal method, in different healing periods, of smooth and texturized standard model implants, installed in male New Zealand rabbit tibiae, submitted or not to low intensity laser irradiation. For the study, 16 animals, weighing between 3. 5 to 4. 0 kg, with two implants in each tibia, divided in four groups (control and laser for 16 and 30 days of healing) have been used. The laser (AsGaAl) was irradiated with a wave length of 830 nm, continuous mode and power of 100 mW, and the punctual application was 1 J/cm2 in three points and eight applications, with 48 hours intervals, started immediately after the implant installation surgery, in a total of 24 J/cm2. After the healing period, the animals were sacrificed and the tibiae were removed for the implant torque removal measurements with a manual digital torquemeter. The torque removal results for the control groups were: smooth implants, 16 days, 20. 42±3. 06Ncm, and 30 days 27. 42±19. 65Ncm; texturized implants, 16 days, 22. 67±11. 07Ncm, and 30 days 30. 46±16. 06Ncm. for the laser groups, the results were, smooth implants, 16 days, 19. 15±4. 65Ncm, and 30 days, 30. 08±4. 14Ncm; texturized implants, 16 days, 20. 48±6. 72Ncm, and 30 days, 23. 45±10. 40Ncm. The Factorial Analysis of Variance showed that there is a significant difference for this research results if only the time factor is analyzed and it has been observed that, on the 30 days period, the torque removal values are higher than those for the 16 days period. / Este trabalho avaliou o efeito do laser (AsGaAl) através de torque de remoção, em diferentes períodos de cicatrização, de implantes modelo standard lisos e texturizados, colocados em tíbias de coelhos machos da raça Nova Zelândia, submetidos ou não à irradiação com laser de baixa intensidade. Para o estudo foram utilizados 16 animais, pesando entre 3,5 a 4,0 quilos, sendo inseridos dois implantes em cada tíbia, divididos em quatro grupos (controle e laser para 16 e 30 dias de cicatrização). O laser (AsGaAl) foi aplicado com comprimento de onda de 830nm, modo contínuo e potência de 100mW, sendo a aplicação pontual de 1J/cm² em três pontos e oito aplicações, com intervalo de 48 horas, iniciada imediatamente após a cirurgia de colocação dos implantes, perfazendo um total de 24J/cm². Após o período de cicatrização, os animais foram mortos, então, realizada a remoção das tíbias e, em seguida, a medição dos torques para remoção dos implantes com torquímetro elétrico digital de empunhadura manual. Os resultados de torque de remoção obtidos para os grupos controle: Implantes lisos com 16 dias (20,42±3,06Ncm) e 30 dias (27,42±19,65Ncm); implantes texturizados com 16 dias (22,67±11,07Ncm) e 30 dias (30,46±16,06Ncm). Para os grupos laser: Implantes lisos com 16 dias (19,15±4,65Ncm) e 30 dias (30,08±4,14Ncm); implantes texturizados com 16 dias (20,48±6,72Ncm) e 30 dias (23,45±10,40Ncm). A partir dos resultados da Análise de Variância Fatorial, verificou-se que existe diferença significativa para os resultados desta pesquisa sob analise do fator isolado “tempo”, onde observou-se que, no período de 30 dias, os valores do torque de remoção são superiores ao periodo de 16 dias.
114

Efeito da distribuição ântero-posterior de implantes em próteses tipo overdentures: análise de elemento finito com modelo tridimensional

Broilo, Josué Ricardo January 2008 (has links)
Made available in DSpace on 2011-12-27T14:14:28Z (GMT). No. of bitstreams: 2 000408026-0.pdf: 2274366 bytes, checksum: c74123e225ad17adb904436b3651eaa4 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / This study using 3D-finite element analysis compared the stress distribution generated by a static vertical load on implant-supported overdenture as a function of implant position and attachment system. Tridimensional models were built from the images of a computerized tomography of a mandible and 3D laser digitalization of implants, abutments, mucosa, and complete denture. Four models were built: model 1 – implants inserted at the regions of teeth 43 and 33 (standard implant distribution) and Locator attachment (3i – Implant Innovation) attachment, model 2 – implants position as in model 1 and Dal-Ro attachment (3i – Implant Innovation), model 3 – implants placed at the regions of teeth 44 and 34 (alternative implant distribution) and Locator attachment, and model 4 – implants position as in model 3 and Dal-Ro attachment. The geometric models were converted into finite element models using a commercial software. A 100 N load simulating a masticatory bolus was applied at the first molar region of each model. The von-Mises stress distribution was analyzed and compared in selected points. The largest area of stress distribution on the alveolar ridge occurred in the models with standard implant distribution with attachments Locator® and Dal Ro®. The models with alternative implant distribution had the best performance because they showed the smallest area of stress distribution. The models with attachments Dal Ro® had better biomechanical behavior than the ones with attachments Locator® as the pattern of stress distribution was more uniform along the implant axis, although the stress magnitude was larger in these models. The results suggest that the anterior-posterior distribution of implants in MAs with attachments Locator® and Dal Ro® showed a viable biomechanical behavior. / O objetivo deste trabalho foi avaliar, através de análise por elementos finitos, o comportamento biomecânico de uma técnica alternativa de distribuição de implantes em overdentures e dois sistemas de attachments: Locator® (3i – Implant Innovation) e Dal-Ro® (3i – Implant Innovation). Foram estudadas as tensões geradas em modelos tridimensionais variando-se a localização ânteroposterior dos implantes osseointegrados em uma mandíbula edêntula e o tipo de attachment. Foram gerados modelos tridimensionais de uma mandíbula edêntula a partir das imagens de tomografia computadorizada helicoidal, e dos attachments, da prótese total, da placa resiliente e dos implantes através de digitalização a laser em três planos. Foram construídos quatro modelos: modelo padrão (MP) 1 - implantes inseridos na região dos caninos (dentes 43 e 33) e sistema Locator; MP 2 – implantes inseridos como no modelo 1 e sistema Dal-Ro, modelo alternativo (MA) 3 – implantes inseridos na região dos dentes 44 e 34 e sistema Locator, (MA) 4 – implantes inseridos como no modelo 3 e sistema Dal- Ro. Os modelos geométricos foram importados para o programa ANSYS 10. 0, no qual foi gerada a malha de elementos finitos. Uma carga vertical estática de 100 N foi aplicada sobre uma simulação de bolo alimentar, na região de primeiro molar inferior direito, sendo analisadas e comparadas as distribuições de tensão de Von Mises geradas.A maior área de distribuição de tensão no rebordo alveolar ocorreu nos modelos padrão com attachments Locator® e Dal Ro®, sendo o melhor desempenho conferido aos modelos alternativos em função da menor área de distribuição das tensões. Os modelos com attachments Dal Ro® mostraram-se mais favoráveis do ponto de vista biomecânico em relação aos attachments Locator®, pois o padrão de distribuição de tensões foi mais uniforme ao longo do seu eixo, apesar da magnitude dessas tensões serem maiores nestes modelos. Pode-se concluir que a distribuição ântero-posterior para os MAs com attachments Locator® e Dal Ro® apresentaram um comportamento biomecânico viável.
115

Influência do laser de baixa potência (GaAIAs - λ830nm) na formação óssea em implantes lisos e texturizados: uma análise histomorfométrica

Torres, Marco Antônio Rambo Osório January 2007 (has links)
Made available in DSpace on 2011-12-27T14:14:31Z (GMT). No. of bitstreams: 2 000399356-0.pdf: 4105847 bytes, checksum: 0c59a09fa1073f779a885d9635fec74e (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / This research in vivo blind-controlled was to investigate post mortem, through the histomorphometrical analysis, the influence of the low power laser in bone formation on machined and roughened titanium dental implants inserted in rabbits tibia-bones. The animals were subjected or not to the GaAlAs irradiation laser device, with a length of wave of 830nm, in a continuous form during 10 seconds, with a power output of 100mW. A total of six white New Zealand rabbits were equally and randomly divided into two groups, irradiated and controlled groups, where four implants were placed in each animal. Two machined were implanted in the right tibia and two roughened in the left tibia. The experimental group received irradiation through the skin in three points around the implants, during 15 days, every 48 hours. The first application was performed in the same day of the surgery, with a total of eight days of irradiation and total dose of 24J/cm2 in each tibia (3 points x 1J x 8 applications = 24J). The control group were submitted to the same routine of the irradiated animals, however with the laser equipment turned off. After 30 days all animals suffered euthanasia, and histological sections were obtained. The sections were then stained with toluidine blue. Each section was reduced to a final thickness of about 10 to 19μm. The bone-to-implant contact measurements in percentage were performed by using two central sections from each sample, blinded form, were photomicrographed on optical microscope connected to an image analyzer digital program. The averages obtained from the two sections of each implant right after the blinding belittled were compared in general form between laser and control groups and among the four sub-groups were performed by using Student’s t-test. There was no statistically significant difference (p> 0,05) in the percentage of bone-to-implant contact between the laser (77,048 % ± 10,173) and control groups (69,516 % ± 19,284) in a general form, not even between the sub-groups roughened with laser (81,530 % ± 10,155), roughened control (72,190 % ± 16,778), machined with laser (72,565 % ± 8,737) and machined control (66,842 % ± 22,791). In the present research, results suggest that the low power laser, with the irradiated protocol, did not significantly contribute for increasing the percentage of bone-to-implant contact. Nevertheless, new formed bone undergone to the with GaAlAs irradiation laser device during the period of osseointegration, it seems to present a bigger vasculature and lamellar organization compared to the control group, suggesting bone maturation improvement. However, further research is necessary to better explain the biological mechanisms of low power laser action on the mediation of necessary process for titanium implants osseintegration as well as dosimetric parameters for getting bone biostimulation. / Este trabalho in vivo controlado e com cegamento avaliou post mortem, através da análise histomorfométrica, a influência do laser de baixa potência na formação óssea em implantes lisos e texturizados inseridos em tíbias de coelhos, submetidos ou não à irradiação com laser de GaAlAs com comprimento de onda de 830nm, de forma contínua por 10 segundos, com potência de 100mW. Para tanto foram utilizados seis coelhos da raça Nova Zelândia, distribuídos igualmente de forma aleatória em grupo irradiado e grupo controle, onde cada coelho recebeu quatro implantes, sendo dois lisos na tíbia direita e dois texturizados na tíbia esquerda. Os animais do grupo experimental receberam irradiação transcutaneamente em três pontos ao redor dos implantes, durante 15 dias a cada 48 horas, sendo a primeira aplicação no dia da cirurgia, com total de oito dias de irradiação e dose total de 24J/cm2 em cada tíbia (3 pontos x 1J x 8 aplicações = 24J).Os animais do grupo controle foram submetidos à mesma rotina dos animais irradiados, porém com equipamento laser desligado. Após 30 dias todos os animais sofreram eutanásia para obtenção de lâminas histológicas coradas com azul de toluidina a partir de cortes das tíbias com os implantes inseridos numa espessura final de 10 a 19μm. Para avaliação do percentual de contato osso-implante os dois cortes mais centrais de cada amostra, de forma cegada, foram fotomicrografados em microscópio óptico e analisados através de um programa digital de processamento de imagens. As médias obtidas a partir dos dois cortes de cada implante, após desfeito o cegamento, foram comparadas de forma geral e dentro dos grupos utilizando-se o teste t-student. Não houve diferença estatisticamente significativa (p>0,05) no percentual de contato osso-implante entre os grupos laser (77,048% ± 10,173) e controle (69,516% ± 19,284) de forma geral, nem entre os subgrupos texturizado com laser (81,530% ± 10,155), texturizado controle (72,190% ± 16,778), liso com laser (72,565% ± 8,737) e liso controle (66,842% ± 22,791).Estes resultados sugerem que o laser de baixa potência, com o protocolo de irradiação utilizado neste modelo animal, não contribuiu significativamente para o aumento do percentual de contato osso-implante. Não obstante, o osso novo formado submetido à irradiação com laser de GaAlAs durante o período de ossoeintegração, parece apresentar uma maior vascularização e organização lamelar que o grupo controle, sugerindo uma maior maturação. Porém, são necessárias novas pesquisas de modo a preencher as lacunas ainda existentes quanto ao entendimento dos mecanismos biológicos da ação do laser de baixa potência na mediação dos processos necessários à osseointegração de implantes de titânio, bem como dos parâmetros dosimétricos para obtenção da bioestimulação óssea.
116

Torque de remoção, caracterização de superfície e histomorfometria de implantes dentários com diferentes superfícies: estudo em cães

Marin, Charles January 2010 (has links)
Made available in DSpace on 2011-12-27T14:14:32Z (GMT). No. of bitstreams: 2 000430369-0.pdf: 669885 bytes, checksum: 002b0553e91e6ef0df52888b901e3907 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this study is evaluate 3 implant surfaces in dogs at early times of ossointegration. Forty eight implants (Ti-6Al4V) were used: Resorbable Blasted Media Acid Etched (RBMa), Alumina Blasted Acid Etched (AB/AE) as control group and Alumina Blasted Acid Etched + Resorbable Blasted Media Acid Etched (AB/AE + RBMa). Tree implants per group were utilized for fisico/chemical characterization (SEM, AFM and XPS). For the animal procedure 3 implants were placed on proximal tibiae bilaterally and remained for 2 weeks in vivo (8 dogs, 16 per surface, 6 per dog). Following euthanasia half of implants were torque to interface failure and other half for non-dehydrated histological processing to final sections of ≈30μm for bone to implant contact (%BIC) and bone arial fraction ocuppied (BAFO). The GLM ANOVA at 95% of significance and Dunn’s post-hoc were used for statistical analysis. AB/AE group presented higher values of Sa e Sq than groups RBMa and AB/AE + RBMa. Ti, Al, O, C, N, Ca and P were observed in groups RBMa and AB/AE + RBMa, for AB/AE group Ti, Al, O, C, N and V were observed. No statistical difference was observed for histomorfometric parameters (%BIC and BAFO) among groups. All surfaces are biocompatible and osseoconductive, newly formed woven bone was observed in proximity with all surfaces. / O objetivo deste estudo é determinar em cães, a influência dos tratamentos de superfície através de jateamento com biocerâmicas nos períodos iniciais de osseointegração. Quarenta e oito implantes (Ti-6Al-4V) tratados com jateamento com biocerâmica seguido de ataque ácido (RBMa), jateamento com alumina e ataque ácido (AB/AE) usado como controle, jateamento com alumina e ataque ácido com subsequente jateamento com biocerâmica e ataque ácido (AB/AE + RBMa). Três implantes de cada grupo foram destinados a caracterização físico/química por microscopia eletrônica de varredura (SEM), microscopia de força atômica (AFM) e Espectroscopia Fotoelétrica de Raios X (XPS). O estudo animal compreendeu a colocação de 48 implantes na porção proximal da tíbia (8 cães, 16 por superfície, 6 por cão) os quais permaneceram por 2 semanas in vivo. Após a eutanásia, metade dos espécimes foram destinados ao teste de torque de remoção e a outra metade foram processadas para obtençao de lâminas não descalcificadas de aproximadamente 30μm de espessura onde foram realizadas análises histomorfológica e histomorfométrica de contato osso/implante (%BIC) e fração arial de osso formado (BAFO). O teste GLM ANOVA com 95% de significância foi utilizados para análise estatística com post-hoc de Dunn. A AFM demonstrou valores de rugosidade (Sa e Sq) significante maiores do grupo AB/AE em relação aos grupos RBMa e AB/AE + RBMa. O XPS demonstrou presença de Ti, Al, O, C, N, Ca e P para os grupos RBMa e AB/AE + RBMa, os mesmos elementos foram em contrados no grupo AB/AE, juntamente com o V, exceto Ca e P. Não foram encontradas diferenças estetísticas para %COI e BAFO. Todos os grupos demonstraram bicompatibilidade com osso imaturo observado em íntimo contato com as superficies.
117

Análise do efeito sistêmico da LLLT em região perimplantar : estudo em coelhos

Mayer, Luciano January 2013 (has links)
Submitted by Ginamara Lima (ginaj@pucrs.br) on 2013-04-17T13:33:15Z No. of bitstreams: 1 447176.pdf: 2750615 bytes, checksum: 6db2237c9889f4756aec07a95d930df2 (MD5) / Made available in DSpace on 2013-04-17T13:33:16Z (GMT). No. of bitstreams: 1 447176.pdf: 2750615 bytes, checksum: 6db2237c9889f4756aec07a95d930df2 (MD5) / Este estudo é parte de um projeto que teve por objetivo avaliar o efeito da terapia com laser de baixa intensidade pós-implante dentário osseointegrável no funcionamento da glândula tireoide e, consequentemente, na regulação do cálcio, através da mensuração dos níveis hormonais de Triiodotironina (T3), Tiroxina (T4) e dos níveis de Cálcio e Albumina no soro sanguíneo de coelhos. Foi avaliado o efeito de 3 doses terapêuticas distintas de LLLT utilizadas para aceleração do processo de osseointegração de implantes dentários. Para tanto, foram utilizados 40 coelhos da ordem Lagomorpha, raça Nova Zelândia, machos, pesando entre 3 e 4 kg, clinicamente sadios, distribuídos aleatoriamente em cinco grupos, com oito animais cada, sendo dois grupos designados como controle: o grupo controle CI (animais não irradiados e não operados) e o grupo controle CII (animais não irradiados); e três grupos designados como experimentais: EI, EII e EIII – animais irradiados com três doses distintas de laser – grupo experimental EI (dose total - 70J/cm²), grupo experimental EII (dose total - 35J/cm²) e grupo experimental EIII (dose total - 140J/cm²). Para padronizar os experimentos, todos os animais dos grupos CII, EI, EII e EIII foram submetidos ao procedimento cirúrgico de exodontia do incisivo inferior esquerdo e colocação imediata de um implante osseointegrável com superfície nanotexturizada (Nanotite® - Biomet 3iTM) no respectivo alvéolo, criando uma condição clínica inicial de igualdade entre os quatro grupos operados. Os animais do grupo controle CI participaram da mesma rotina dos demais; no entanto, não foram submetidos a nenhum dos procedimentos clínicos/cirúrgicos, servindo como controle absoluto nos testes imunológicos para contagem de T3, T4, Cálcio e Albumina. Os animais dos grupos experimentais foram irradiados com o laser de diodo infravermelho com meio ativo GaAlAs (Arseneto de Gálio e Alumínio), com comprimento de onda de 830nm, de forma pontual, com potência de 50mW, no modo de emissão contínua, a cada 48 horas, num total de sete sessões de aplicação, durante o período de 13 dias. O protocolo de irradiação foi iniciado imediatamente após o procedimento cirúrgico. As coletas de sangue para dosagens laboratoriais de T3, T4, Cálcio e Albumina foram realizadas por meio de punção venosa da veia jugular nos cinco grupos em quatro momentos distintos: 72 horas antes do procedimento cirúrgico, imediatamente após a primeira aplicação de laser, 72 horas após a primeira aplicação de laser e 72 horas após a última aplicação de laser. Os resultados obtidos demonstraram diferenças estatisticamente significativas para os valores de T3 e Cálcio entre os grupos estudados e para os valores de T3, T4, Cálcio e Albumina nos diferentes tempos de coleta ao longo do experimento. Conclui-se que a LLLT, no protocolo de irradiação utilizado neste estudo, apesar de ter alterado significativamente os níveis hormonais de T3 e T4 e os níveis de Cálcio e Albumina circulantes no soro de coelhos, não comprometeu definitivamente o funcionamento da glândula tireoide dos mesmos, pois na etapa final do controle hormonal percebe-se o restabelecimento da função glandular. / This study is part of a larger project that sought to assess the effect of lowlevel laser therapy (LLLT) after placement of an osseointegrated dental implant on thyroid gland function – and, consequently, calcium regulation – and its potential interference with the osseointegration process. Toward this end, circulating serum levels of triiodothyronine (T3), thyroxine (T4), calcium, and albumin were measured in rabbits. The effects of three therapeutic doses of LLLT, used to accelerate the dental implant osseointegration process, were assessed. Forty healthy male New Zealand rabbits (order Lagomorpha), weight 3–4 kg, were allocated randomly across five groups of eight each: two control groups, CI (no LLLT, no surgery) and CII (no LLLT), and three experimental groups, EI, EII, EIII, exposed to three different doses of laser radiation (EI, total dose 70 J/cm²; EII, total dose 35 J/cm²; and EIII, total dose 140 J/cm²). For standardization purposes, all animals in groups CII, EI, EII, and EIII underwent surgical extraction of the mandibular left incisor and immediate placement of a nanoparticle-coated osseointegrated implant (NanoTite® – Biomet 3iTM) into the prepared socket, creating a condition of equality between groups at baseline. Animals in group CI were exposed to the same handling conditions, but did not undergo any clinical or surgical procedures, thus serving as an absolute control for T3, T4, calcium, and albumin measurements. Animals in the experimental groups received spot irradiation with a GaAlAs (gallium aluminium arsenide) infrared diode laser, wavelength 830 nm, power 50 mW, in continuous emission mode, over two points, every 48 hours over 13 days, for a total of seven sessions; the irradiation protocol was started immediately after the surgical procedure. Blood was collected for measurement of T3, T4, calcium, and albumin levels, by puncture of the external jugular vein, at four points in time: 72 hours before surgery, immediately after the first LLLT session, 72 hours after the first LLLT session and 72 hours after the last LLLT session. The results showed significant differences in T3 and calcium levels between study groups, as well as significant within-group differences in T3, T4, calcium, and albumin levels over time. We conclude that, despite a significant effect on circulating serum levels of T3, T4, calcium and albumin, the LLLT protocol used in this study did not lead to impairment of thyroid function in a rabbit model, because in the final stage of the hormonal control it is noticed the reestablishment of glandular function.
118

ESTUDO DE PRIMEIROS PRINCÍPIOS DO GRAFENO INTERAGINDO COM CLUSTERS DE DIÓXIDO DE TITÂNIO

Silva Júnior, José Solon da 28 March 2018 (has links)
Submitted by MARCIA ROVADOSCHI (marciar@unifra.br) on 2018-08-17T20:13:05Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_JoseSolonDaSilvaJunior.pdf: 4702814 bytes, checksum: f3853067fbfa9aca7b0ecd88eaf5c6e9 (MD5) / Made available in DSpace on 2018-08-17T20:13:05Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_JoseSolonDaSilvaJunior.pdf: 4702814 bytes, checksum: f3853067fbfa9aca7b0ecd88eaf5c6e9 (MD5) Previous issue date: 2018-03-28 / Recent studies demonstrate the effectiveness of nanostructures in dentistry. Some applications reduce physiological implications, such as the non-acceptance of a dental implant by the body. A promising nanostructure in several areas of knowledge that has been little explored for this purpose is graphene. In this work, we studied the interaction of adsorbed graphene with phosphorus (P), silver (Ag) and calcium (Ca) atoms with titanium dioxide clusters (TiO2), with nomenclature (TiO2)n, with n varying from 1 to 3. The aim of this study is to identify systems that are relevant to the area of implantology, i. e., nanosystems that could facilitate the adhesion of the implant to the organism. The dopant atoms were chosen because of their biocompatibility with bone tissue (P and Ca) and antibacterial properties (Ag). The clusters of TiO2 were used to mimic the oxide that is usually formed on titanium implants. For this, we performed calculations of first principles, based on the Density Functional Theory, as implemented in the SIESTA code. The exchange and correlation potential was treated within the generalized gradient approximation and the description of the valence electrons was done using the pseudopotential method. The results showed that the interaction of graphene adsorbed with calcium with TiO2 clusters is the most promising system that meets the purposes of the work. The adsorption energies for this case vary from 2.41 eV to 4.70 eV, indicating a strong interaction. In the case of silver-adsorbed graphene, the adsorption energies are lower, but still characterize a strong interaction, which varies from 1.31 eV for the cluster with n = 2 and 2.05 eV for the cluster with n = 3. For the cluster with n = 1, the value found for the adsorption energy was 1.92 eV. The system that was not relevant to the objectives of this work was the graphene adsorbed with phosphorus interacting with the clusters. In this case, the adsorption energies were high, 3.42 eV for (TiO2)1, and 2.16 eV for (TiO2)3, however, we observed that the cluster removed the atoms adsorbed from the graphene. For the cluster (TiO2)2, the interaction was weak, with an adsorption energy of 0.46 eV. These results, while theoretical, show that graphene can be a potential candidate for the creation of thin films to be used in the coating of titanium implants. / Estudos recentes demonstram a eficácia do emprego de nanoestruturas na odontologia. Certas aplicações reduzem implicações fisiológicas como, por exemplo, a não aceitação de um implante dentário pelo organismo. Uma nanoestrutura promissora em várias áreas do conhecimento e que tem sido pouco explorada para este fim, é o grafeno. Assim, neste trabalho, estudamos a interação do grafeno adsorvido com átomos fósforo (P), prata (Ag) e cálcio (Ca) com clusters de dióxido de titânio (TiO2), com nomenclatura (TiO2)n, onde n varia de 1 a 3. O objetivo desse estudo consiste em apontar sistemas que sejam relevantes para a área de implantodontia, ou seja, nanosistemas que pudessem facilitar a adesão do implante ao organismo. Os átomos dopantes foram escolhidos por apresentar biocompatibilidade com o tecido ósseo (P e Ca) e propriedades antibactericidas (Ag). Já os clusters de TiO2 foram utilizados com o intuito de mimetizar o óxido que geralmente se forma sobre os implantes de titânio. Para isso, realizamos cálculos de primeiros princípios, baseados na Teoria do Funcional da Densidade, conforme implementado no código SIESTA. O potencial de troca e correlação foi tratado dentro da aproximação do gradiente generalizado e a descrição dos elétrons de valência foi feita utilizando o método de pseudopotenciais. Os resultados obtidos mostraram que a interação do grafeno adsorvido com cálcio com os clusters de TiO2, é o sistema mais promissor que atende os propósitos do trabalho. As energias de adsorção para esse caso variam de 2,41 eV a 4,70 eV, indicando uma interação forte. Já para o caso do grafeno adsorvido com prata, as energias de adsorção são mais baixas, mas ainda assim caracterizando uma interação forte, as quais variam de 1,31 eV para o cluster com n = 2 e 2,05 eV para o cluster com n = 3. Para o cluster com n = 1, o valor encontrado para a energia de adsorção foi de 1,92 eV. O sistema que não se mostrou relevante para os objetivos do trabalho foi o grafeno adsorvido com fósforo interagindo com os clusters. Nesse caso, as energias de adsorção foram altas, 3,42 eV para o (TiO2)1, e 2,16 eV para o (TiO2)3, porém, observamos que o cluster afastou o átomos adsorvido do grafeno. Para o cluster (TiO2)2, a interação foi fraca, com uma energia de adsorção de 0,46 eV. Esses resultados, embora teóricos, mostram que o grafeno pode ser um candidato potencial para a criação de filmes finos, a serem utilizados no revestimento de implantes de titânio.
119

Influência da zircônia no arrefecimento de brocas para implantes osseointegráveis: ensaio mecânico

Souza, Edmo Matheus Rocha de 31 August 2015 (has links)
Specimens were made from bovine ribs and milling divided into two groups (A - B mills in steel - mills in zirconia), each group was divided into four subgroups according to different settings milling (rotation and pressure milling). They were measured and compared the temperatures of the milling burs made by the two materials made using four different configurations. A prosthetic surveyor has been adapted to the study to connect a surgical electronic engine, counter angle driver for implants. A container was also coupled to one of the liner's arms to accommodate components metallic spheres of standard weight, sometimes 1.2kg, 2.4kg moment according to the configuration of each subgroup such that the surgical motor that ran milling in 1000 and 2000 rpm. In order to measure milling temperatures, they used two thermocouples of the same make and model in two depths milling, the first and the second 5mm to 15mm. All the cutters are subjected to washing and antisepsis every two tests. The heat generated by the friction between bone and surgical instrumentation during such drills tend to be imparted to this tissue degeneration resulting protein that cause scarring and can be decisive in higher failure rates. Several factors are potentially destined to contribute to increasing the temperature for the osteotomies of which insufficient irrigation, using worn drills, surgical instrumentation outside the standard suggested by the manufacturer and the material constituting the object of this study surgical drills. / Corpos de prova foram confeccionados a partir de costela bovina e as fresagens divididas em dois grupos (A – fresas em aço martensíntico e B – fresas em zircônia), cada grupo foi subdividido em quatro subgrupos de acordo com configurações diferentes de fresagem (rotação e pressão de fresagem). Foram aferidas e comparadas as temperaturas das fresagens realizadas por brocas confeccionadas nos dois materiais através de quatro configurações diferentes. Um delineador protético foi adaptado ao estudo para conectar-se um motor eletrônico cirúrgico, propulsor de contra ângulo para implantes. Um recipiente também foi acoplado a um dos braços do delineador para que acomodasse esferas metálicas componentes do peso padrão, ora 1,2kg, ora 2,4kg de acordo com a configuração de cada subgrupo tal qual o motor cirúrgico que executava fresagens em frequências de 1000 e 2000 rpm . Para mensuração das temperaturas de fresagem, foram utilizados dois termopares da mesma marca e modelo em duas profundidades de fresagem, a primeira a 5mm e a segunda a 15mm. Todas as fresas foram submetidas à lavagem e degermação a cada dois testes. O calor gerado através da fricção entre osso e brocas durante essas instrumentações cirúrgicas tende a ser transmitido a este tecido provocando degeneração proteica que acarretam cicatrizes e podem ser determinantes para taxas de insucesso mais altas. Diversos fatores estão potencialmente predestinados a contribuir com o aumento da temperatura durante as osteotomias dentre os quais, irrigação insuficiente, utilização de brocas desgastadas, instrumentação cirúrgica fora do padrão sugerido pelos fabricantes e material constituinte das brocas cirúrgicas-objeto desse estudo.
120

Componentes calcináveis para implantes Cone Morse: análise da desadaptação entre pilar / implante

Levasseur, Caio Marcelus Pais 30 April 2015 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2015-12-08T11:13:05Z No. of bitstreams: 1 caiomarceluspaislevasseur.pdf: 4546598 bytes, checksum: be57e1ab62ac45ae2f9ffe3e165c9e75 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2015-12-09T13:38:24Z (GMT) No. of bitstreams: 1 caiomarceluspaislevasseur.pdf: 4546598 bytes, checksum: be57e1ab62ac45ae2f9ffe3e165c9e75 (MD5) / Made available in DSpace on 2015-12-09T13:38:24Z (GMT). No. of bitstreams: 1 caiomarceluspaislevasseur.pdf: 4546598 bytes, checksum: be57e1ab62ac45ae2f9ffe3e165c9e75 (MD5) Previous issue date: 2015-04-30 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Os sistemas de implantes osseointegráveis se apresentam em um ou mais componentes, e a correta inter-relação, passividade de assentamento e resistência biomecânica, definem a resistência / vulnerabilidade do mesmo frente aos fatores bacterianos e oclusais. Objetivo: Avaliar as deformações inerentes ao processamento laboratorial dos pilares calcináveis de corpo único para o sistema de implantes Cone Morse. Materiais e métodos: Utilizou-se 20 implantes Cone Morse da marca SIN, 10 componentes protéticos calcináveis e 10 não calcináveis. Após os processos laboratoriais, os conjuntos foram submetidos à Microscopia eletrônica de varredura (MEV) da interface pilar/implante, para análise qualitativa e quantitativa da desadaptação gerada. Os conjuntos foram levados a ciclos térmicos (1.000 ciclos) e de fadiga mecânica (500.000 ciclos) e novamente foi realizada a MEV. Os resultados foram comparados através de análise estatística de Mean-Whitmann. Resultados: O grupo de teste (G1) apresentou os maiores valores iniciais, com média de 34, 55 μm e 11,17 μm, para a subdivisões A (fundição) e B (aplicação de porcelana) respectivamente. A subdivisão B do grupo teste apresentou a maior alteração pós testes, com média de 19,28 μm de aumento da desadaptação protética. As subdivisões G1.A, G2.A, G2.B mostraram tendência à diminuição da desadaptação de -1,03 μm, - 1,64 μm, e -0,49 μm, respectivamente. Pilares Cone Morse não calcináveis apresentam-se com alta estabilidade e baixa taxa de desadaptações. Para o grupo teste pode-se afirmar que o processo de fundição nitidamente criou as maiores dilatações e desadaptações das estruturas. O processo de sinterização da porcelana em teste, criou uma redução da desadaptação medida, porém esta voltou a aumentar após os testes em laboratório. Para o grupo controle, houve a manutenção das taxas de desadaptações menores ao limite de 10 μm, e com tendência de redução após os testes. Conclusão: O pilar calcinável Cone Morse de corpo único mostrou-se como desfavorável quanto à biomecânica, e o processo de fundição gerou as maiores desadaptações. / The system of dental implants present in one or more components, and the correct interrelationship, settling and passive biomechanical strength, defining the strength / vulnerability of the same to the forward occlusal and bacterial factors.Objective: To evaluate the defects associated to laboratory processing of abutments of unique body to the system of Cone Morse implants. Methods: We used 20 Cone Morse implants SIN brand, prosthetic components 10 and 10 calcinable not calcinable. After the laboratory processes the sets were subjected to scanning electron microscopy (SEM) of the pillar / implant interface, for qualitative and quantitative analysis of the generated misfit. The samples were taken to alternated thermal cycles (1000 – 50 and 550) and mechanical fatigue (500,000 - 120 N/cm2) and again was carried out by SEM. The results were compared by statistical analysis Mean-Whitmann (P>0,05). Results: The test group (G1) showed the highest initial values, averaging 34.55 and 11.17 micrometres for subdivisions A (casting) and B (porcelain application) respectively. The B subdivision of the test group showed the greatest change after tests, averaging 19.28 mm of increasing prosthetic misfit. The G1.A subdivisions, G2.A, G2.B showed a tendency to decrease the mismatch of -1.03 micrometres - 1.64 micrometres and -0.49 micrometres respectively. Pillars Cone Morse calcinable not present with high stability and low rate misfits. For the test group it can be said that the casting process clearly created the largest expansion and mismatches of structures. The porcelain sintering process under test, created a reduction of the mismatch measure, however this increased again after the tests in the laboratory. For the control group, there was the maintenance of rates of minor mismatches to 10 micrometres limit, and with downward trend after the tests. Conclusion: Cone Morse castable pillars proved to be unfavorable on the biomechanics, and the casting process generated the biggest misfits.

Page generated in 0.0961 seconds