• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1598
  • 689
  • 348
  • 186
  • 180
  • 93
  • 71
  • 54
  • 46
  • 32
  • 19
  • 18
  • 11
  • 10
  • 7
  • Tagged with
  • 3972
  • 574
  • 489
  • 467
  • 464
  • 428
  • 404
  • 399
  • 370
  • 360
  • 330
  • 315
  • 311
  • 306
  • 306
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1101

Avaliação da anatomia mandibular e suas variações por meio da tomografia computadorizada de feixe cônico em uma população brasileira / Evaluation of mandibular anatomy and its variations by cone beam computed tomography in a brazilian population

Cunha, Rodrigo Montezano da January 2016 (has links)
O conhecimento da localização, bem como da configuração das estruturas anatômicas presentes na mandíbula e suas respectivas variações são extremamente importantes para o planejamento de procedimentos cirúrgicos que envolvam este osso. O presente estudo teve como objetivo avaliar a anatomia mandibular e suas variações por meio da tomografia computadorizada de feixe cônico (TCFC) em uma população brasileira. Foram utilizados 1254 exames de TCFC realizados no equipamento I-Cat Next Generation, (Imaging Sciences International®) sob um protocolo com voxel de 0,2 mm, FOV amplo (16cm x 13cm) e tempo de escaneamento de 40 segundos. Três examinadores treinados e calibrados avaliaram os exames por meio do software I-Cat Vision (Imaging Sciences International®). Os dados que foram coletados em um formulário Access (Microsoft® Office) e analisados para prevalência, também foram correlacionados, isolando as variáveis gênero e situação dentária (dentado total, dentado parcial e desdentado total. Os resultados de prevalência foram: forame mentual localizado entre o 1º e 2º pré-molar inferior (91,38%), alça anterior (12,57%), canais acessórios (40%), canal mandibular bífido (CMB) (22%) e canal mandibular corticalizado (33,84%). O canal mandibular, em toda sua extensão, está localizado mais para vestibular nas mulheres, com diferença estatisticamente significante entre gêneros (P=0,002). Não foi encontrada diferença na distância V-L na região de fóvea submandibular entre os gêneros. Os CMBs não tem predileção por gênero (P=0,186), havendo diferença estatisticamente significante entre os tipos (P=0,001), sendo o Retromolar o mais frequente. O uso dos exames de TCFC permitiu identificar características anatômicas mandibulares importantes em uma população brasileira, sugerindo que essas devam ser investigadas antes de intervenções cirúrgicas. / The knowledge of the location, as well as the configuration of the anatomical structures and their respective variations are extremely important for the planning of surgical procedures involving this bone. The aim of this study was evaluate the mandibular anatomy and its variations through Cone Beam Computed Tomography (CBCT) in a Brazilian population. A total of 1254 CBCT scans were performed on the I-Cat Next Generation (Imaging Sciences International®) equipment under a protocol with 0.2 mm voxel, wide FOV (16cm x 13cm) and 40 seconds scanning time. Three trained and calibrated examiners evaluated the exams using I-Cat Vision software (Imaging Sciences International®). The data that were collected in Access form (Microsoft® Office) and analyzed for prevalence. In line, were correlated with gender. The prevalence results were: mental foramen located between the 1st and 2nd lower premolars (91.38%), anterior loop (12.57%), accessory canals (40%), bifid mandibular canal (BMC) (22%) and corticalized mandibular canal (33.84%). The mandibular canal, in all its extension, is located more for vestibular in the women, with statistically significant difference between genders (P = 0,002). There is no difference in V-L distance between genders in submandibular fovea area. The BMCs do not have a gender preference (P = 0.186). However, there is a statistically significant difference between the types (P = 0.001), and Retromolar is the most frequent. The use of CBCT scans allowed the identification of important mandibular anatomical features in a Brazilian population, suggesting that these should be investigated before surgical interventions.
1102

Síntese de memórias resistivas de TiO2 e caracterização por feixe de íons

Sulzbach, Milena Cervo January 2017 (has links)
Neste trabalho foi desenvolvido um estudo sistemático dos mecanismos de difusão responsáveis pelo switching de resistência em memórias resistivas. Essas memórias possuem estrutura semelhante a de um capacitor, a qual sofre uma transição de resistência induzida pela aplicação de um campo elétrico. A transição é provocada pela formação de filamentos condutivos no interior da matriz semicondutora. Os filamentos podem ser constituídos por metal originado de um dos eletrodos (ECM) ou por regiões do óxido deficientes em oxigênio (VCM), geradas pela difusão de vacâncias de oxigênio. Dispositivos de TiO2 foram construídos e sua resposta elétrica foi adquirida através de medidas elétricas do tipo I-V para diferentes metais de eletrodo. Técnicas de análise por feixe de íons, como retroespalhamento Rutherford por micro-feixe e perfilometria com reação nuclear ressonante, foram usadas para detalhamento dos processos de difusão. Constatou-se uma dependência do comportamento elétrico em função do método de deposição da camada semicondutora, sua espessura e os parâmetros da medida de tensão. No caso do filamento ser composto por átomos de metal, espectros de micro-RBS foram adquiridos para identificar a sua estrutura no interior do óxido. Ainda, observaram-se bolhas na superfície do eletrodo superior dos dispositivos com difusão de vacâncias de oxigênio após o tratamento elétrico. Nesse mesmo contexto, foi medida a difusividade e energia de ativação da difusão de oxigênio em filmes finos de TiOy. / In this work we developed a systematic study of diffusion mechanisms which are responsible for resistance switching in resistive memories. The structure of these memories is similar to a capacitor which suffers resistance transition induced by electrical field. The transition is caused by the formation of conductive filaments inside the semiconductor matrix. The filaments may be constituted by metal from one of the electrodes (ECM) or by oxygen deficient areas (VCM), generated from oxygen vacancies diffusion. Devices of TiO2 have been built and its electrical response was acquired through electrical measurements (I-V) for different electrode metals. Ion beam techniques such as micro-probe Rutherford Backscattering and Nuclear Reaction Profiling were used to detail the diffusion processes. It was observed a dependence in the electrical behaviour with the semiconductor layer deposition method, its thickness and bias measurement parameters. In the case which filaments are composed by metal atoms, measurements of micro-RBS were performed to identify its structure inside the oxide. Also, bubbles have been observed over the surface of top electrode in devices with oxygen vacancies diffusion after the electrical treatment. In this context, it was measured diffusivity and activation energy for oxygen diffusion in thin TiOy films.
1103

Mesure interférométrique de phase et application à la combinaison cohérente d’un grand nombre de fibres amplificatrices / Interferometric phase measurement and its application for coherent fiber beam combining of a large number of amplifiers

Antier-Murgey, Marie 17 November 2014 (has links)
Les propriétés intrinsèques des fibres amplificatrices telles que leur robustesse, leur efficacité, leur qualité de faisceau ou encore leur compacité ou leur bonne gestion thermique, en font un candidat idéal pour le développement de sources lasers de haute puissance, capables de rivaliser aujourd’hui avec les lasers solides. Les applications de ces sources avec de fortes puissances sont nombreuses : l’industrie (usinage, marquage), la défense (télémétrie, imagerie), la physique des particules. Dans ce dernier cas, des sources ultra-brèves et ultra-intenses permettent d’envisager de nouvelles applications telles que la proton-thérapie ou bien le remplacement des synchrotrons actuels par des architectures moins encombrantes et ayant un rendement plus important. Ce travail de thèse s’est déroulé dans le contexte du projet ICAN qui vise à étudier l’architecture de ces nouvelles sources.La combinaison cohérente de plusieurs amplificateurs fibrés en parallèle permet d’augmenter la puissance de ces sources. Pour atteindre les énergies visées dans le projet ICAN, la combinaison cohérente de 10 000 fibres doit être envisagée. L’objectif de cette thèse est de développer des techniques de contrôle de la phase compatibles avec un très grand nombre de fibres, pour leur application aux lasers ultra-intenses nécessaires à la physique des particules.Deux architectures de combinaison cohérente basées sur une mesure de phase interférométrique ont été réalisées dans cette thèse. La première, basé sur l’holographie numérique, permet un contrôle de la phase sans aucun calcul, collectif tant au niveau de la mesure que de la correction. La seconde architecture possède un contrôle actif de phase basé sur un algorithme de traitement d’images et elle a une bande passante compatible avec le spectre de bruit des amplificateurs. La combinaison cohérente de 16 fibres à 1kHz avec une erreur résiduelle de phase de λ/60mrs a été démontrée. La compatibilité de ces deux architectures avec 10 000 fibres a été étudiée et nous avons apporté quelques éléments pour la combinaison cohérente d’un très grand nombre de fibres. / The intrinsic properties of optical fibers like robustness, efficiency, beam quality, compactness and good thermal management can now compete with solid state lasers to develop high power laser sources. The applications of such sources include industry (machining, marking), defense (telemetry, lidar), and fundamental research. In this case, high intensity lasers are compulsory to produce the next generation of particles accelerators more efficient and more compact, both for fundamental research and its direct applications such as proton therapy. This work was done in the context of the ICAN project, which studies the feasibility of such sources.To overcome the limitations in terms of power of a single amplified fiber, an idea is to use several fiber lasers and to combine them coherently. To reach the ultra-high peak power and high average power requirements for these applications, the coherent beam combining of 10,000 fiber amplifiers has to be envisaged. The goal of the work is to develop a scheme of phase control scalable to a high number of combined fibers.Two schemes based on an interferometric phase measurement are realized in this work. The fist scheme, based on digital holography, permits a collective phase measurement and correction without calculation. The second scheme is based on an active phase control with individual phase modulators. This control requires an image processing algorithm and has a bandwidth compatible with the phase spectral noise of the amplifiers. The coherent combining of 16 fibers at 1kHz with a residual phase shift error of λ/60rms is achieved in this case. We use this second scheme to evaluate its scalability. We show that the coherent combining of 10,000 fibers using off-the-shelf components is already possible.
1104

Epitaxial growth and optical properties of Mg3N2, Zn3N2, and alloys

Wu, Peng 24 April 2019 (has links)
Zinc nitride and magnesium nitride are examples of the relatively unexplored II3V2 group of semiconductor materials. These materials have potential applications in the electronics industry due to their excellent optical and electrical properties. This study mainly focuses on the growth and characterization of the new semiconductor materials: zinc nitride, magnesium nitride, and their alloys. The (100) oriented zinc nitride thin films were grown on both (110) sapphire substrates and (100) MgO substrates by plasma-assisted molecular beam epitaxy (MBE). The typical growth rate is in the range of 0.02-0.06 nm/s, the growth temperature is in the range of 140-180 oC, and background nitrogen pressure is around 10-5 Torr. The growth process was monitored by in-situ: reflection high energy electron diffraction (RHEED) and optical reflectivity. The RHEED and X-ray diffraction patterns of the zinc nitride indicate that the film is a single crystal material. The in-situ optical reflectivity pattern of the zinc nitride shows interference oscillations, and these oscillations are damped out as the thickness increases. The reflectivity as a function of time was accurately simulated by an optical equation. The optical constants of the thin films, the growth rate, and the thickness were derived from the simulation of the in-situ reflectance. The X-ray diffraction shows that (400) oriented zinc nitride thin films were grown on both A-plane (110) sapphire substrates and (100) MgO substrates. Optical transmittance measurements were performed on the zinc nitride thin films. The spectrum of the zinc nitride transmittance indicates that zinc nitride has a high optical absorption in the visible light region. The absorption coefficient was calculated from the transmittance spectrum, and the optical band gap of the zinc nitride thin film was found to be 1.25-1.28 eV. Ellipsometry measurements suggested that the refractive index of zinc nitride is 2.3-2.7, and the extinction coefficient is ~0.5-0.7 in the energy range 1.5-3.0 eV. The electron transport measurement shows that the single crystal zinc nitride has a mobility as high as 395 cm2 /Vs. A plasma-assisted MBE system was employed for magnesium nitride growth. The growth temperature was in the range of 300-350 oC. RHEED and laser reflectivity were employed during growth. The RHEED and X-ray diffraction patterns indicated that the epilayers are single crystal films. The optical laser reflectivity was well fitted by a modified optical equation. The optical constants and growth rate were derived from the simulation. X-ray diffraction showed that (400) oriented single crystal magnesium nitride films were grown on (100) MgO substrates. The optical transmittance spectra show that the magnesium nitride has a high absorption below 500 nm. The calculated absorption coefficient is as high as 4x10-4 cm-1 in the range of ~2.5-3.0 eV. The optical band gap was estimated to be ~2.5 eV. Ellipsometry measurements showed that the refractive index of the magnesium nitride is 2.3-2.75 and the extinction coefficient is less than 0.3 in the energy range of 1.5-3.0 eV. Zinc nitride-magnesium nitride (Zn3-3xMg3xN2) alloys were grown on (100) YSZ substrates by sputtering. The bandgap ranged from 1.2 eV to 2.1 eV for Mg content x in the 0-0.59 range. One film with a bandgap of ~1.4 eV and Mg content of 0.18 has the relatively high mobility of 47 cm2 /Vs which was expected for photovoltaics application. / Graduate
1105

Avaliação dos efeitos do Sistema Damon nas inclinações dentárias, dimensões dos arcos e suporte ósseo alveolar por meio da tomografia computadorizada de feixe cônico / Changes in arch dimensions, buccolingual inclinations and alveolar bony support during alignment using Damon MX: a CBCT study

Morais, Juliana Fernandes de 28 November 2012 (has links)
Avaliação dos efeitos do Sistema Damon nas inclinações dentárias, dimensões dos arcos e suporte ósseo por meio da tomografia computadorizada de feixe cônico Este estudo objetivou analisar as alterações nas inclinações vestibulolinguais dos dentes, nas dimensões dos arcos e nas espessuras das tábuas ósseas vestibulares durante o alinhamento com Sistema Damon, como também identificar fatores pré-tratamento (espessura óssea inicial, larguras dos arcos, apinhamento) e alterações do tratamento (expansão dos arcos, vestibularização dos dentes) possivelmente associados. Vinte e dois adolescentes com dentadura permanente completa até primeiros molares, tratados sem extrações e apinhamento inicial mínimo de 4mm superior: -6,71mm (DP 2,99), inferior: -5,12mm (DP 2,03) foram escaneados por tomografia computadorizada de feixe cônico (TCFC) antes (T0) e após (T1) o alinhamento com o Sistema Damon. As dimensões dos arcos e as inclinações vestibulolinguais dos dentes foram avaliadas a partir das TCFC (T0 e T1) em modelos 3D e cortes multiplanares, enquanto o apinhamento foi mensurado nos modelos de estudo (T0). A spessura das tábuas ósseas vestibulares nos ¾ coronais e ¼ apical da raiz dentária foram mensuradas por meio de imagens de tomográficas parassagitais (0,3mm de espessura) das duas fases T0 e T1, nas áreas de incisivos centrais superiores e de segundos pré-molares e primeiros molares superiores e inferiores. As variáveis foram submetidas ao teste de de Shapiro-Wilk para testar sua distribuição. As alterações de todas as variáveis de T0 para T1 foram comparadas por meio dos testes t pareado ou de Wilcoxon. A correlação entre as alterações das espessuras ósseas com os possíveis fatores associados foi verificada pelo coeficiente de correlação de Pearson ou teste de correlação de Spearman. O alinhamento com o Sistema Damon produziu expansões dos arcos associados à proclinação dos dentes e à redução na espessura óssea vestibular. As tábuas ósseas vestibulares tornaram-se não mensuráveis com o alinhamento em 25% das raízes mesiovestibulares dos primeiros molares superiores. A redução nas espessuras ósseas vestibulares mensuráveis, recobrindo os ¾ coronais da raiz, foi significante nas áreas de incisivo central superior (-13,22%), raiz mesiovestibular do primeiro molar superior (-20,54%) e raízes mesial e distal do primeiro molar inferior (-15,58% e -11,38%, respectivamente). Houve tendência ao aumento da espessura óssea vestibular da raiz distovestibular do primeiro molar superior (p= 0,051), provavelmente devido à rotação do molar com o alinhamento. A redução na espessura óssea vestibular durante o alinhamento dentário mostrou correlação positiva com a espessura óssea e apinhamento iniciais no arco superior, bem como com a distância inter-segundos-prémolares pré-tratamento no arco inferior. Os arcos mais expandidos durante a fase de alinhamento tenderam a sofrer maior redução nas espessuras ósseas vestibulares. Conclui-se que o Sistema Damon produz expansões dos arcos associados à redução óssea vestibular durante a fase de alinhamento. Dentes com ossos mais finos e apinhamentos mais severos antes do tratamento apresentam maior risco para redução na tábua óssea vestibular e a quantidade de expansão durante o tratamento pode potencializar esse efeito. / This study aimed first to assess the changes in teeth buccolingual inclinations, arch dimensions, and buccal bony plate thicknesses occurred during the alignment phase using a self-ligating brackets system (Damon MX). Secondly, to identify pre-treatment (initial bone thickness, initial arch widths, initial crowding) or treatment parameters (amount of expansion, amount of buccal tipping) that could act as risk predictors for buccal bone reduction during orthodontic treatment. Twenty-two adolescents with complete permanent dentition until first molars, minimum initial crowding of 4mm - maxillary: -6.71 mm (SD 2.99), mandibular: - 5.12 mm (SD 2.03) - treated without extractions were scanned by cone beam computed tomography (CBCT) before (T0) and after (T1) alignment using Damon System. Arch dimensions and teeth buccolingual inclinations were evaluated by means of digital models and multiplanar reconstructed images both obtained from CBCT (T0 and T1), crowding was measured on study casts (T0). Alveolar buccal bone thickness overlying the ¾ coronal and the ¼ apical of the root were measured in the areas of maxillary central incisors, as well as maxillary and mandibular premolars and first molars by means of cross-sectional images reconstructed with 0.3 mm thickness at T0 and T1, Distribution of the variables was verified by Shapiro-Wilks test. Changes in all variables from T0 to T1 were compared using paired t test or Wilcoxon test. The correlation between changes in bone thickness with its possible associated factors was assessed by Pearson correlation coefficient or Spearman correlation test. Alignment using Damon System produced substantial arch expansion associated with proclination of teeth and reduction in buccal bone thickness. The buccal bone plates overlying 25% of the mesiobuccal roots of the maxillary first molars became unmeasurable during the alignment phase. The reduction in the measurable buccal bone thickness, overlying the ¾ coronal root length, was significant in the areas of maxillary central incisor (-13.2%), mesiobuccal root of maxillary first molar (-20.5%), mesial and distal roots of mandibular first molar (-15.6% and -11.4%, respectively). There was a tendency for increasing buccal bone thickness root overlying the distobuccal root of maxillary first molar (p = 0.051), probably due to molar rotation during the alignment phase. The reduction in buccal bone thickness during alignment with Damon System showed a positive correlation with initial bone thickness and initial crowding in the maxillary arch, and the pre-treatment inter-secondpremolar width in the mandibular arch. The more expanded the arch during the alignment phase, the greater reduction in buccal thickness bone. It is concluded that the Damon system produces arch expansion associated with decrease in buccal bone thickness during the alignment phase. Thinner buccal bony plates and more severe crowding before treatment increase the risk for buccal bone reduction and the amount of expansion during treatment may further enhance this effect.
1106

Análise do comportamento estrutural de ligações parafusadas viga-pilar com chapa de topo estendida / Analysis of the structural behavior of bolted beam-column extended end plate connections

Maggi, Yuri Ivan 26 May 2004 (has links)
Este trabalho apresenta uma análise numérica e experimental sobre o comportamento estrutural de ligações parafusadas viga-pilar com chapa de topo estendida. Discute-se, em particular, o comportamento da chapa de topo e dos parafusos na determinação da capacidade resistente dessas ligações. A análise de resultados numéricos é utilizada como base para as discussões neste trabalho e a modelagem numérica, realizada em elementos finitos com o software ANSYS, incluiu modelos tridimensionais de ligações com chapa de topo estendida e de ligações duplo “T". Com os resultados numéricos e experimentais, os mecanismos de transferência dos esforços entre viga e pilar e os mecanismos de plastificação da chapa de topo e dos parafusos são observados, avaliando-se as linhas de plastificação na chapa de topo em confronto com a metodologia proposta pelo Eurocode 3 na determinação dos perfis “T" equivalentes. Para esses fatores, observou-se que os modos de falha indicados pelo Eurocode 3 não representam satisfatoriamente o comportamento das ligações analisadas. A modelagem numérica, por sua vez, mostrou-se generalista e representativa como ferramenta para análises paramétricas e como complemento de análises experimentais / This work presents a numerical and experimental analysis on the structural behavior of bolted beam-column extended end plate connections. The behavior of the end plate and bolts used in the calculations of the end plate strength is specially discussed. Numerical results are used as basis to the discussions presented in this work and the modeling methodology, with FE models built with the ANSYS code, included 3D models of extended end plate and T-stub connections. The beam-to-column load transfer mechanisms and the yielding mechanisms at end plates and bolts are observed using numerical and experimental results. The yielding lines at the end plate are evaluated against the methodology proposed by Eurocode 3 for the calculations on the equivalent T-stub. Regarding the aforementioned factors, it is shown that the collapse modes indicated by Eurocode 3 do not represent satisfactorily the behavior of the analyzed connections. The numerical modeling was found to be general in application and reliable as a tool for parametric analyses and as a complement to experiments
1107

Intensidade de pixel e sua correlação com o índice de qualidade óssea de mandíbulas atróficas / Pixel intensity and its correlation with bone quality index of atrophic mandibles

Zambrana, Jessica Rabelo Mina 20 May 2016 (has links)
O sucesso do tratamento de implantes dentários depende da quantidade e qualidade óssea da área de interesse e o uso da Tomografia Computadorizada por Feixe Cônico (TCFC) pode ser correlacionado para a sua estimativa. O objetivo deste estudo foi avaliar e comparar os níveis de escala de cinza dos voxels de imagens obtidas por TCFC de mandíbulas atróficas com o auxílio de programa para diagnóstico e planejamento de implantes e correlacionar a Intensidade Pixel (IP) com a classificação subjetiva do Índice de Qualidade Óssea (IQO). Foram avaliadas imagens tomográficas de 10 mandíbulas atróficas obtidas do banco de dados do LAPI-FOUSP (Laboratório para Análise e Processamento de Imagens) que receberam 8 marcações em regiões normalmente utilizadas para colocação de implantes (4 em região anterior e 4 em região posterior), sobre estas foram posicionados fios ortodônticos para padronização dos cortes tomográficos e simular posições ideais de implantes. Cortes transaxiais das áreas demarcadas foram obtidas para visualização e análise de 4 regiões corticais e 3 regiões trabeculares do tecido ósseo de cada corte, para a seleção de área foi utilizada a ferramenta Região de Interesse (ROI) de cada programa. As imagens foram analisadas por 3 programas de planejamento Romexis (Planmeca,Finlandia), XoranCAT® (Xoran Technologies, EUA) e OsiriX® (Free Software Foundation, 32 bits, EUA). Os dados foram submetidos a análise estatística de Correlação de Spearman em um nível de significância de 5% (p<0,05), análise de correlação intraclasse intra-observador e inter-observador pelo teste Kappa ponderado e o teste qui-quadrado. Os resultados apresentaram que os programas Romexis e OsiriX apresentaram melhor acuidade para a avaliação subjetiva de qualidade óssea, em contrapartida o programa Xoran apresentou inconsistência de dados. Concluiu-se que há correlação entre Intensidade de Pixel e Qualidade óssea de acordo com os resultados encontrados para os programas OsiriX e Romexis / The success of dental implants treatment depends on the bone quantity and quality of the area of interest and the use of Cone Beam Computed Tomography (CBCT) can be correlated to an estimative. The aim of this study was to evaluate and compare the grey scale levels of voxels obtained by CBCT of atrophic mandibles with the aid of software for diagnosis and planning implants and correlates the Pixel Intensity (PI) with the subjective classification of Bone Quality Index (BQI). Tomographic images of 10 atrofic mandibles obtained from the data base of LAPI-FOUSP (Laboratory of analysis and imaging processing) were evaluated, received 8 marks in areas normally used for implant placement (4 in anterior and 4 in posterior region) on these orthodontic wires were positioned for standardization of tomographic images and simulate optimal implant positions. Transaxial slices of the demarcated areas were made for visualization and analysis of four regions of interest for cancellous bone and three regions of interest for cortical bone and for selection of each area a tool called Region of Interest (ROI) was used by each software. The images were analised by three diferent planning software, Romexis (Planmeca, Finland), XoranCAT® (Xoran Technologies, EUA) e OsiriX® (Free Software Foundation, 32 bits, EUA). Data were subjected to statistical analysis of Spearman correlation, intraclass intra-observer and inter-observer analysis correlation and weighted Kappa concordance coefficient with 5% significance level and chi-squared test; The results presented that Romexis and OsiriX software showed better accuracy for subjective assessment of bone quality, on the other hand Xoran software showed data inconsistency. This study concluded that a correlation was found between Pixel Intensity (PI) and Bone Quality (BQ) due to the results of OsiriX and Romexis software.
1108

Validação de medidas maxilofaciais por meio da tomografia computadorizada por feixe cônico em 3D / Assessment of linear and angular measurements on three-dimensional conebeam computed tomographic images

Moreira, Carla Ruffeil 01 October 2009 (has links)
O objetivo deste estudo foi demonstrar a precisão e a acurácia de medidas maxilofaciais lineares e angulares obtidas por tomografia computadorizada por feixe cônico (TCFC). A amostra consistiu de quinze crânios humanos secos submetidos à TCFC. Medidas lineares e angulares foram realizadas em imagens em terceira dimensão (3D) após a identificação de pontos craniométricos convencionais. As imagens em 3D-TCFC foram analisadas por dois radiologistas, duas vezes, independentemente. Medidas físicas foram realizadas por um terceiro examinador utilizando paquímetro e goniômetro digitais. Os resultados não demonstraram diferenças estatísticas significantes para as análises intra e interexaminadores. As comparações entre as medidas físicas e as obtidas em 3D-TCFC para ambos os examinadores também não foram estatisticamente significantes tanto para as medidas lineares quanto paras as angulares (p= 0,968 e 0,915, p= 0,844 e 0,700, respectivamente). As imagens em 3D-TCFC podem ser utilizadas com precisão e acurácia para a obtenção de medidas lineares e angulares a partir de estruturas anatômicas e pontos craniométricos. / The purpose of this research was to provide further evidence to demonstrate the precision and accuracy of maxillofacial linear and angular measurements obtained by cone-beam computed tomography (CBCT) images. The study population consisted of 15 dry human skulls that were submitted to a CBCT, and threedimensional (3D) images were generated. Linear and angular measurements based upon conventional craniometric anatomical landmarks, were identified in 3D-CBCT images by two radiologists twice each independently. Subsequently physical measurements were made by a third examiner using a digital caliper and a digital goniometer. The results demonstrated no statistically significant difference between inter and intra-examiner analysis. Regarding accuracy test, no statistically significant difference were found of the comparison between the physical and CBCT-based linear and angular for both examiners (p= 0.968 and 0.915, p= 0.844 and 0.700 respectively). 3D-CBCT images can be used to obtain dimensionally accurate linear and angular measurements from bony maxillofacial structures and landmarks.
1109

Avaliação da disponibilidade óssea para enxertos, na região posterior da mandíbula, por meio da tomografia computadorizada de feixe cônico / Evaluation of available bone for grafting in the posterior mandible by means of cone beam computed tomography

Grandizoli, Dayane Kemp 07 March 2016 (has links)
O estudo anatômico dos ossos dos maxilares é de extremo interesse devido à elevada demanda por procedimentos cirúrgicos como implantes osseointegrados e cirurgias ortognáticas. Embora uma variedade de substitutos ósseos seja utilizada para restabelecer a quantidade necessária de osso para instalação de implantes, existe um particular interesse em relação aos enxertos ósseos autógenos, que se mostram superiores, principalmente pela previsibilidade e altas taxas de sucesso. O objetivo desse trabalho foi quantificar o volume ósseo disponível na região posterior de mandíbula através da Tomografia Computadorizada de Feixe Cônico. A TCFC permite realizar medições com precisão e é uma ferramenta útil para avaliação préoperatória em cirurgia odontológica, já que o campo de imagem relativamente pequeno limita a exposição do paciente à radiação. Foram analisados 1.500 exames de TCFC e selecionados 70 exames do arquivo de imagens do Departamento de Estomatologia da Faculdade de Odontologia de Bauru, avaliados bilateralmente nas reformatações panorâmica e parassagitais através do software i-Cat Vision®. Na literatura não há consenso entre parâmetros e limites de osso. Dessa forma, foram definidas algumas referências: a distal da coroa do primeiro molar inferior como o limite anterior do enxerto e o local onde a cúspide mais alta dos molares cruza a borda anterior do ramo ascendente da mandíbula como o limite posterior do enxerto. Nessa região avaliou-se comprimento, altura, espessura de osso e volume da cortical óssea vestibular para enxertia óssea. Os resultados mostraram um volume médio de 859,26 mm3, sendo que a espessura média do osso cortical foi de 2,60mm, o comprimento médio foi de 18,98mm e a média de altura de 17,33mm. Esses valores mostram que a região posterior da mandíbula pode ser utilizada com segurança como área doadora de osso autógeno para reconstrução de pequenos defeitos e, usando esta estimativa de disponibilidade óssea, o cirurgião estará mais seguro para enfrentar os desafios da reconstrução maxilofacial. / The anatomical study of the bones of the jaw is of extreme interest due to the high demand for surgical procedures such as dental implants and orthognathic surgery. Although a variety of bone substitutes are used for restoring the necessary amount of bone for implant placement, there is a particular interest in relation to autogenous bone grafts, which are superior primarily by the predictability and high success rates. The aim of the present study was to quantify the bone volume available on the posterior region of the mandible through Cone Beam Computed Tomography. CBCT allows for an accurate measurement and is a useful tool for preoperative evaluations in dental surgery, since the relatively small image field limits the patient\'s exposure to radiation. Thousand five hundred CBCT exams were analyzed and selected seventy exams of the archives of images from the Department of Stomatology, Bauru School of Dentistry, bilaterally assessed in panoramic and parasagittal reformatting through the i-Cat Vision® software. In the literature there is no consensus between parameters and bone limits. Thus, we determined some references: the distal of the first mandibular molar crown as the anterior limit of the graft, and where the highest cuspid of mandibular molars crosses the anterior border of the ascending ramus of the mandible as the posterior limit of the graft. In this region were evaluated length, height, bone thickness and volume of the vestibular cortical bone for bone grafting. The results showed an average volume of 859.26mm3, while the average thickness of cortical bone was 2.60mm, an average length of 18.98mm and an average height of 17.33mm. These values show that the posterior mandible can be safely used as donor area of autologous bone to rebuild small areas, and using this estimate of available bone, the surgeon will be safer to face the challenges of maxillofacial reconstruction.
1110

Laser de Nd:YAG de alta potência, estabilidade e qualidade de feixe / High power Nd:YAG laser with high stability and beam quality

Pinto, Regiane de Souza 30 July 2014 (has links)
O trabalho experimental aqui apresentado tem como foco o desenvolvimento de um laser de estado sólido cujo desempenho foi otimizado de tal forma que contemple alta potência, alta qualidade de feixe e estabilidade, levando-se em conta os efeitos térmicos sofridos pelo meio ativo em regime de alta potência de bombeamento. Foram testadas cavidades para operação contínua em multimodo com alta potência de saída e cavidades operando em modo único TEM00. Para cavidades operando no modo fundamental, os ressonadores testados serão divididos em grupos de acordo com o seu comportamento no diagrama de estabilidade. A otimização de tais ressonadores foi realizada apenas alterando-se o raio de curvatura dos espelhos de entrada e saída e suas respectivas distâncias ao plano principal do bastão de Nd:YAG. Como resultado foi alcançada a maior eficiência de extração reportada na literatura para um ou dois módulos de Nd:YAG intracavidade. Os resultados dão uma visão geral sobre possíveis projetos de ressonadores para operação dinamicamente estável, com alta potência de saída e qualidade de feixe. Os dados obtidos servem como base para o desenvolvimento de novos lasers de alta potência e eficiência baseados em módulos DPSSL (Diode-Pumped Solid-State Lasers- Lasers de Estado Sólido Bombeados por Diodo) de baixo custo. / The experimental work presented here focuses on the development of a solid-state laser whose performance has been optimized for high power output, high beam quality, and high stability, taking into account the thermal effects experienced by the gain medium under high pumping power. Cavities for continuous wave (CW) operation in multimode with high output power and cavities operating in single mode TEM00 were tested. The resonators will be divided in groups according to their stability diagram. The optimization of such resonators was performed only by changing the curvature radius of the mirrors and their distances to the principal plane of the Nd:YAG rod. As a result was achieved the highest extraction efficiency reported in the literature for one or two intra cavity Nd:YAG modules. The results give an overview of possible designs of resonators for dynamically stable operation with high output power and beam quality. The data serve as basis for the development of new high-power lasers based on low cost DPSSL modules.

Page generated in 0.0463 seconds